Advertisement for orthosearch.org.uk
Results 1 - 20 of 25
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 62 - 62
1 Dec 2020
Yildirim K Beyzadeoglu T
Full Access

Background. Return to sports after anterior cruciate ligament reconstruction (ACLR) is multifactorial and rotational stability is one of the main concerns. Anterolateral ligament reconstruction (ALLR) has been recommended to enhance rotational stability. Purpose. To assess the effect of ALLR on return to sports. Study Design. Retrospective comparative cohort study;. Level of evidence: III. Methods. A total of 68 patients who underwent ACLR after acute ACL injury between 2015 and 2018 with a follow-up of at least 24 months were enrolled in the study. Patients with isolated ACLR (group ALL(-), n=41) were compared to patients with ACLR+ALLR (group ALL(+), n=27) in regard to subjective knee assessment via Tegner activity scale, Anterior Cruciate Ligament-Return to Sport after Injury (ACL-RSI) scale, Knee Documentation Committee (IKDC) form and Lysholm score. All tests were performed before the surgery, at 6 months and 24 months postoperatively. Results. Mean follow-up was 29.7±2.9 months for group ALL(-) and 31.6±3.0 for ALL(+) (p=0.587). Tegner, ACL-RSI and IKDC scores at last follow-up were significantly better in ALL(+) compared to ALL(-). There were no significant differences in isokinetic extensor strength and single-leg hop test results between the groups. 40 (97.6%) patients in ALL(-) and 27 (100%) in ALL(+) had a grade 2 or 3 pivot shift (p=0.812) preoperatively. Postoperatively, 28 (68.3%) patients in ALL(-) and 25 (92.6%) patients in ALL(+) had a negative pivot shift (p<0.001). 2 (5.9%) patients in ALL(-) and 1 (3.7%) patient in ALL(+) needed ACLR revision due to traumatic re-injury (p=0.165). There was no significant difference in the rate of return to any sports activity (87.8% in ALL(-) vs 88.9% in ALL(+); p=0.532), but ALL(+) showed a higher rate of return to the same level of sports activity (55.6%) than group ALL(-) (31.7%) (p=0.012). Conclusion. ACLR combined with ALLR provided a significantly higher rate of return to the same level sports activity than ACLR alone, probably due to enhanced rotational stability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 12 - 12
1 Apr 2017
Yasuda T Yokoi Y Oyanagi K Hamamoto K
Full Access

Background. Non-contact anterior cruciate ligament (ACL) injuries occurs with a higher incidence in female athletes compared with males after the onset of puberty. One anatomical factor with clinically observable differences between males and females is lower extremity alignment. The knee joint valgus in the coronal plane, which is associated with ACL injury risk, is composed of rotation of the tibia around the stationary femur and hip rotation combined with knee flexion. The purpose of this study was to prove the difference of hip rotation between female and male handball players with or without history of ACL injury. Methods. Elite collegiate athletes on the varsity handball team (17 females and 24 males) were recruited. Whereas 8 females and 1 male had a history of ACL injury, there were 9 females and 23 males with no history of ACL injury. The 6 measures of hip joint motion [flexion, extension, abduction, adduction, external rotation (ER), and internal rotation (IR)] and the 2 measures of knee joint motion (flexion and extension) were measured with the standard procedure using a goniometer. Results. The range of ER in ACL-injured females (37±7.5) was smaller than in uninjured females (49±8.2). The range of IR in ACL-injured female players (55±9.6) was greater than in uninjured females (41±13). There was no difference in ER+IR between ACL-injured and uninjured females. In the ACL-injured male handball player, ER was dominant to IR. Compared with the uninjured males, the ACL-injured female players showed smaller range of ER, greater ranges of IR and greater ER+IR. Conclusions. ACL-injured female handball players had greater hip IR with smaller hip ER, compared with uninjured counterpart. Hip rotation may be a crucial risk factor for ACL injury in female athletes. Level of evidence. 2b


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 31 - 31
1 May 2012
Findlay C Jameson S Marshall S Walker B Walker C Meek R Nicol A
Full Access

Background. Following an anterior cruciate ligament (ACL) injury, the affected knee is known to experience bone loss and is at significant risk of becoming osteoporotic. Surgical reconstruction is performed to attempt to restore the function of the knee and theoretically restore this bone density loss. Cross-sectional analysis of the proximal tibia using peripheral quantitative computed tomography (pQCT) enables localised analysis of bone mineral density (BMD) changes. The aim of this study was to establish the pattern of bone density changes in the tibia pre- and post- ACL reconstruction using pQCT image analysis. Methods. Eight patients who underwent ACL reconstruction were included. A cross sectional analysis of the proximal tibia was performed using a pQCT scanner pre-operatively and one to two years post-operatively on both the injured and contralateral (control) knee. The proximal two and three percent slices [S2 and S3] along the tibia were acquired. These were exported to Matlab(tm) and automated segmentation was performed to remove the tibia from its surrounding structures. Cross correlation was applied to co-register pairs of images and patterns of change in BMD were mapped using a t-test (p<0.05). Connected components of pixels with significant change in BMD were created and used to assess the impact of ACL injury & reconstruction on the proximal tibial BMD. Results. Prior to surgical ACL reconstruction, the BMD in the injured leg was significantly reduced relative to the control leg [S2: p=0.002, S3: p=0.002]. Post surgery, the proximal tibial BMD did not change in either leg [Control S2: p=0.102, S3: p=0.181; Injured S2: p=0.093, S3: p=0.439]. The post surgical images demonstrated patterns of increasing BMD surrounding the tunnel in the form of compact bone. Discussion. A significant reduction in proximal tibial BMD was observed in the ACL injured legs relative to control legs. The pattern of pre-operative bone loss was generally observed to be global across the entire slice. No change in BMD was observed following ACL reconstruction, in either injured or control leg. These results indicate that proximal tibial BMD is reduced and does not change after ACL reconstruction


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 49 - 49
1 Mar 2021
Sasaki K Toshihiro S
Full Access

We report bone bruises on Anterior Cruciate Ligament (hereinafter referred to as ACL) injury. We also investigated the relationship among the presence or absence of bone bruises, localization, and the presence or absence of meniscal injury according to the period of MRI scan from injury.

We underwent the study used a total of 76 knees who underwent ACL reconstruction at our hospital and related hospitals from January 2014 to December 2017. We investigated on MRI images taken after injury. Meniscal injuries were evaluated by intraoperative findings.

The average age at injury was 25.8 years old (13–48 years old) in 44 males and 32 females. Bone bruises were found in 54 of 76 knees (71%). Among them, the ratio of non-contact type was much higher in the group with bone bruises than in the contact group (83% in the group with bone bruises, 64% in the group without bone bruises), resulting in a shorter period from injury to MRI (bone bruises group: 12.4 days, non-bone bruises group: 23 days). Looking at the appearance frequency of bone bruises according to the period from injury to MRI imaging, the appearance frequency of bone bruises decreased as the time to imaging became longer (within 2 weeks of injury: 76%, injury from 2 weeks to 1 month: 65%, injury 1–3 months: 53%). With regard to the localization of bone bruises, in the coronal section, both femurs and tibiae frequently had bone bruises on the outside. In the sagittal section, it occurred in front of the femur, in particular. On the tibial side, many cases of bone bruises occurred in the rear. In addition, the association between bone bruises and meniscal injuries were significantly complicated with lateral meniscal injury in the group without femoroconstriction in the group with lateral femoral bone bruises and in the group with posterior tibia bone bruises. There was no significant association between bone bruises and meniscal injury among the other groups.

Bone bruises were found in 54 of 76 knees (71%). Regarding the occurrence of many lateral developments, it is thought that the tibia is sub-dislocated anteriorly due to mild flexion, valgus force, and external rotation injury, and injury is caused by axial pressure applied to the outside of the femur and posterior of the tibia It was done. As a result, it was considered that the external meniscal injury was injured. The medial unilateral development of bone contusion was observed in 3 knees on the medial femur and 1 knee on the medial tibia. All internal single-cased cases are contact-type injuries, the result of which may be different in the mechanism of bone contusion development.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 16 - 16
17 Apr 2023
Hornestam J Miller B Carsen S Benoit D
Full Access

To investigate differences in the drop vertical jump height in female adolescents with an ACL injury and healthy controls and the contribution of each limb in this task. Forty female adolescents with an ACL injury (ACLi, 15.2 ± 1.4 yrs, 164.6 ± 6.0 cm, 63.1 ± 10.0 kg) and thirty-nine uninjured (CON, 13.2 ± 1.7 yrs, 161.7 ± 8.0 cm, 50.6 ± 11.0 kg) were included in this study. A 10-camera infrared motion analysis system (Vicon, Nexus, Oxford, UK) tracked pelvis, thigh, shank, and foot kinematics at 200Hz, while the participants performed 3 trials of double-legged drop vertical jumps (DVJ) on two force plates (Bertec Corp., Columbus, USA) sampled at 2000Hz.The maximum jump height normalised by dominant leg length was compared between groups using independent samples t-test. The maximum vertical ground reaction force (GRFz) and sagittal ankle, knee and hip velocities before take-off were compared between limbs in both groups, using paired samples t-test. The normalised jump height was 11% lower in the ACLi than in the CON (MD=0.04 cm, p=0.020). In the ACLi, the maximum GRFz (MD=46.17N) and the maximum velocities of ankle plantar flexion (MD=79.83°/s), knee extension (MD=85.80°/s), and hip extension (MD=36.08°/s) were greater in the non-injured limb, compared to the injured limb. No differences between limbs were found in the CON. ACL injured female adolescents jump lower than the healthy controls and have greater contribution of their non-injured limb, compared to their injured limb, in the DVJ task. Clinicians should investigate differences in the contribution between limbs during double-legged drop vertical jump when assessing patients with an ACL injury, as this could help identify asymmetries, and potentially improve treatment, criteria used to clear athletes to sport, and re-injury prevention


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 8 - 8
17 Nov 2023
Alieldin E Samir M
Full Access

Abstract. Introduction. The medial meniscus is crescent shaped and it is wider posteriorly than anteriorly. It covers up to 60 % of the articular surface of medial tibial condyle and helps with the loading distribution in the medial compartment. Meniscal lesions occur in association with ACL tears in 60 % of the time. The posterior aspect of the menisco-capsular junction is known as the meniscal rampzone. If not addressed during surgery, it could lead to unfavourable results. Objective. Incidence of ramp lesion following ACL injuries. Methods. Observational study of 100 patients at EL Hadara Main University Hospital who underwent anterior cruciate ligament reconstruction. MRI and arthroscopic diagnosis was done to detect Ramp lesions associated with ACL ruptures in November 2017 till November 2019. Results. Incidence was 9%. Duration of injury and increased medial meniscal slope were associated with increased incidence of ramp lesion. MRI signs were present in 79% of cases without Ramp lesion, 100% in Cases with ramp lesion. Mode of Injury and presence of locking or giving way symptoms were not associated with increased incidence. Conclusion. The ramp lesion at the posterior aspect of the meniscus is difficult to visualize from standard anterior portals and is, therefore, frequently missed and can be underestimated. Also, there are no specific MRI signs of this lesion. The overall incidence of ramp lesions in 100 cases that had undergone ACL reconstruction in our study was 9 %. It was found also that the longer the duration from injury, the more likely ramp lesion would occur. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 54 - 54
2 Jan 2024
İlicepinar Ö Imir M Cengiz B Gürses S Menderes Y Turhan E Dönmez G Korkusuz F
Full Access

Hop tests are used to determine return to sports after ACL reconstruction. They mostly measure distance and symmetry but do not assess kinematics and kinetics. Recently, biomechanical evaluations have been incorporated into these functional jump tests for the better assessment of return to sport. We assessed the sagittal plane range of motion (ROM) of the knee, the deviation axis of rotation (DAOR), and the vertical ground reaction force (vGRF) normalized to body weight in nine healthy participants during the single leg (SLH) and crossover hop tests (COHT). Participants' leg lengths were measured. Jumping distances were marked in the test area as being 4/5 of the leg length. Four sensors were placed on the thighs, the legs and the feet. These body parts were handled as a single rigid body. Eight 480 Hz cameras were used to capture the movements of these rigid bodies. vGRF at landing were measured using a force plate (Bertec, Inc, USA). The ROM of the knee joint and the DAOR were obtained from kinematic data. Participants' joint kinematics metrics were similar in within-subjects statistical tests for SLH and COHT. We therefore asked whether the repeated vGRF normalized to body weight will be similar in both legs during these jumps. Joint kinematics metrics however were different in between subjects indicating the existence of a personalized jumping strategy. These hop tests can be recorded at the beginning of the training season for each individual, which can establish a comparative evaluation database for prospective lower extremity injury recovery and return to sport after ACL injury


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 18 - 18
4 Apr 2023
Stanley A Jones G Edwards T Lex J Jaere M
Full Access

Knee pain is common, representing a significant socioeconomic burden. Caused by a variety of pathologies, its evaluation in primary-care is challenging. Subsequently, an over-reliance on magnetic resonance imaging (MRI) exists. Prior to orthopaedic surgeon referral, many patients receive no, or incorrect, imaging. Electronic-triage (e-triage) tools represent an innovative solution to address this problem. The primary aim of this study was to ascertain whether an e-triage tool is capable of outperforming existing clinical pathways to determine the correct pre-hospital imaging based on knee pain diagnosis. Patients ≥18 years with a new presentation of knee pain were retrospectively identified. The timing and appropriateness of imaging was assessed. A symptom-based e-triage tool was developed, using the Amazon LEXbotplatform, and piloted to predict five common knee pathologies and suggest appropriate imaging. 1462 patients were identified. 17% of arthroplasty patients received an ‘unnecessary MRI’, whilst 28% of arthroscopy patients did not have a ‘necessary MRI’, thus requiring a follow-up appointment, with a mean delay of three months (SD 2.6, range 0.2-20.2). Using NHS tariffs, a wasted cost through unnecessary/necessary MRIs and subsequent follow-up appointments was estimated at £45,816. The e-triage pilot was trialled with 41 patients (mean age:58.4 years, 58.5% female). Preliminary diagnoses were available for 34 patients. Using the highest proportion of reported symptoms in the corresponding group, the e-triage tool correctly identified three of the four knee pathologies. The e-triage tool did not correctly identify anterior cruciate ligament injuries (n=3). 79.2% of participants would use the tool again. A significant number of knee pathology patients received incorrect imaging prior to their initial hospital appointment, incurring delays and unnecessary costs. A symptom-based e-triage tool was developed, with promising pilot data and user feedback. With refinement, this tool has the potential to improve wait-times and referral quality, whilst reducing costs


Although remnant-preserved ACL reconstruction (ACLR) restores knee joint stability and dampens the problem of acute ACL rupture-induced knee pain, an increasing number of patients still develop post-traumatic osteoarthritis (PTOA) after 10 to 15 years of ACLR. We previously found that remnant-preserved ACLR with concomitant medial and lateral meniscus repair may not prevent cartilage degeneration and weaken muscle strength, while the clinical features of PTOA are not clear. We hypothesized that remnant-preserved ACLR with concomitant medial and lateral meniscus tears is related to early cartilage damage, worse function recovery, patient-reported outcomes (PROs) and delayed duration to return to sports. The aim is to evaluate the remnant-preserved ACLR with complicated meniscal injuries in predicting which patients are at higher risk of osteoarthritic changes, worse function and limited activities after ACLR for 12 months. Human ethical issue was approved by a committee from Xi'an Jiaotong University. 26 young and active patients (24 male, 2 female) with ACL injuries (Sherman type I and II) with concomitant medial and lateral meniscus within 2 months were included from January 2014 to March 2022. The average age of the ACLR+ meniscus repair was 26.77±1.52 (8 right, 5 left) and isolated ACLR control was 31.92±2.61 years old (7 left, 6 right). Remnant-preserved ACLR with a 5- to 6-strand hamstring tendon graft was operated on by the same sports medicine specialists. MRI CUBE-T. 2. scanning with 48 channels was conducted by a professional radiologist. The volume of the ACL graft was created through 3 dimensional MRI model (Mimics 19, Ann Arbor). Anterior Cruciate Ligament OsteoArthritis Score (ACLOAS) was applied to score visible cartilage damage. IKDC 2000 score and VAS were assessed by two blinded researchers. Results were presented as mean± SEM of each group. The cross-sectional area and 3D volume of the ACL graft were greater in the remnant-preserved ACLR+meniscus group compared with isolated ACLR (p=0.01). It showed that ACLR+ meniscus group had early signs of joint damage and delayed meniscus healing regarding ACLOAS compared to control group (p=0.045). MRI CUBE-T. 2. prediction of radiographic cartilage degeneration was not obvious in both groups post remnant-preserved ACLR over 12 months (p>0.05). However, higher VAS scores, lower IKDC scores, and long-last joint swelling were reported in the ACLR+ meniscus repair group at the end of 12 months follow-up. Although remnant-preserved ACLR+ meniscus was able to maintain the restore the knee function, it showed delayed timing (>12 months) to return to play at the pre-injury stage, while no difference between the timing of returning to the normal daily routine of their ACLR knee compared to control (p=0.30). The cost of ACLR+ meniscus (average 10,520.76$) was higher than the control group (6,452.92$, p=0.018). Remnants-preserved ACLR with concomitant injured medial and lateral meniscus repair shows a higher risk of cartilage damage, greater cost, worse functional performance, and longer time for young male patients to return to sports after 12-month follow-up compared to isolated ACLR. Further evidence and long-term follow-up are needed to better understand the association between these results and the risk of development of PTOA in this patient cohort


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 51 - 51
1 Apr 2018
Kamatsuki Y Furumatsu T Miyazawa S Fujii M Kodama Y Hino T Ozaki T
Full Access

Purpose. Injuries of the meniscal attachments can lead to meniscal extrusion. We hypothesized that the extent of lateral meniscal extrusion (LME) was associated with the severity of the lateral meniscus posterior root tear (LMPRT). This study aimed to evaluate the relationship between preoperative LME and arthroscopic findings of LMPRT in knees with anterior cruciate ligament (ACL) injury. Methods. Thirty-four knees that had LMPRTs with concomitant ACL injuries on arthroscopy were evaluated. Patients were divided into two groups, partial and complete root tears, via arthroscopic findings at the time of ACL reconstruction. We retrospectively measured preoperative LMEs using magnetic resonance imaging (MRI). Statistical analysis was performed using the Mann-Whitney U-test and Chi-square test. Results. Twenty-three knees had partial LMPRTs (type 1). Complete LMPRTs were observed in 11 knees (type 2, 2 knees; type 3, 2 knees; and type 4, 7 knees). In the partial LMPRT group, the average LME was 0.43±0.78 mm. In the complete LMPRT group, the average extrusion was 1.99±0.62 mm. A significant difference between these groups was observed in the preoperative LMEs (P<0.01). The receiver operating curve analysis identified an optimal cutoff point of 1.05 mm for the preoperative LME. This LME cutoff had a sensitivity of 100% and specificity of 85% for complete LMPRT. Conclusion. This study demonstrated that preoperative LMEs were larger in complete LMPRTs associated with ACL injuries than in partial LMPRTs. Our results suggest that preoperative MRI-detected LME may be a useful indicator for estimating LMPRT severity in knees with ACL injury


Full Access

Barriers to successful return to previous level of activity following Anterior Cruciate Ligament Recon-struction (ACLR) are multifactorial and recent research suggests that athletic performance deficits persist after completion of the rehabilitation course in a large percentage of patients. Thirty soccer athletes (26.9 ± 5.7 years old, male) with ACL injury were surgically treated with all-inside technique and semitendi-nosus tendon autograft. At 2 years from surgery, they were called back for clinical examination, self-reported psychological scores, and biomechanical outcomes (balance, strength, agility and velocity, and symmetry). Nonparametric statistical tests have been adopted for group comparisons in terms of age, concomitant presence of meniscus tear, injury on dominant leg, presence of knee laxity, presence of varus/valgus, body sides, and return to different levels of sports. Athletes with lower psychological scores showed lesser values in terms of power, resistance and neuromuscular activity as compared to the ones with good psychological scores that showed, instead, better self-reported outcomes (TLKS, CRSQ) and low fear of reinjury (TSK). In the athletes who had a functional deficit in at least one subtest, a safe return to sports could not have been recommended. Our findings confirmed that demographics, physical function, and psychological factors were related to playing the preinjury level sport at mean 2 years after surgery, sup-porting the notion that returning to sport after surgery is multifactorial. A strict qualitative and quantitative assessment of athletes’ status should be performed at different follow-ups after surgery to guarantee a safe and controlled RTP


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 45 - 45
1 Nov 2021
Ramirez SC Stoker A Cook J Ma R
Full Access

Introduction and Objective. Anterior cruciate ligament reconstruction (ACLR) with tendon autografts is the “gold standard” technique for surgical treatment of ACL injuries. Common tendon graft choices include patellar tendon (PT), semitendinosus/gracilis “hamstring” tendon (HT), or quadriceps tendon (QT). Healing of the graft after ACLR may be affected by graft type since the tissue is subjected to mechanical stresses during post-operative rehabilitation that play important roles in graft integration, remodeling and maturation. Abnormal mechanical loading can result in high inflammatory and degradative processes and altered extracellular matrix (ECM) synthesis and remodeling, potentially modifying tissue structure, composition, and function. Because of the importance of load and ligamentization for tendon autografts, this study was designed to compare the differential inflammatory and degradative metabolic responses to loading by three tendon types commonly used for autograft ACL reconstruction. Materials and Methods. With IRB approval (IRB # 2009879) and informed patient consent, portions of 9 QT, 7 PT and 6 HT were recovered at the time of standard of care ACLR surgeries. Tissues were minced and digested in 0.2 mg/ml collagenase solution for two hours and were then cultured in 10% FBS at 5% CO. 2. , 37°C, and 95% humidity. Once confluent, cells were plated in Collagen Type I-coated BioFlex® plates (1 × 10. 5. cells/well) and cultured for 2 days prior to the application of strain. Then, media was changed to supplemented DMEM with 2% FBS for the application of strain. Fibroblasts were subjected to continuous mechanical stimulation (2-s strain and 10-s relaxation at a 0.5 Hz frequency) at three different elongation strains (mechanical stress deprivation-0%, physiologic strain-4%, and supraphysiological strain-10%). 9. for 6 days using the Flexcell FX-4000T strain system. Media was tested for inflammatory biomarkers (PGE2, IL-8, Gro-α, and MCP-1) and degradation biomarkers (GAG content, MMP-1, MMP-2, MMP-3, TIMP-1, and TIMP-2). Significant (p<0.05) difference between graft sources were assessed with Kruskal-Wallis test and post-hoc analysis. Results are reported as median± interquartile range (IQR). Results. Differences in Inflammation-Related Biomarker Production (Figure 1): The production of PGE2 was significantly lower by HT fibroblasts compared to both QT and PT fibroblasts at all timepoints and strain levels. The production of Gro-α was significantly lower by HT fibroblasts compared to QT at all time points and strain levels, and significantly lower than PT on day 3 at 0% strain, and all strain levels on day 6. The production of IL-8 by PT fibroblasts was significantly lower than QT and HT fibroblast on day 3 at 10% strain. Differences in Degradation-Related Biomarker Production (Figure 2): The production of GAG by HT fibroblasts was significantly higher compared to both QT and PT fibroblasts on day 6 at 0% strain. The production of MMP-1 by the QT fibroblasts was significantly higher compared to HT fibroblasts on day 3 of culture at all strain levels, and in the 0% and 10% strain levels on day 6 of culture. The production of MMP-1 by the QT fibroblasts was significantly higher compared to PT fibroblasts at in the 0% and 4% strain groups on day 3 of culture. The production of TIMP-1 by the HT fibroblasts was significantly lower compared to PT fibroblasts on day 3 of culture. Conclusions. The results of this study identify potentially clinically relevant difference in the metabolic responses of tendon graft fibroblasts to strain, suggesting a lower inflammatory response by hamstring tendon fibroblasts and higher degradative response by quadriceps tendon fibroblasts. These responses may influence ACL autograft healing as well as inflammatory mediators of pain in the knee after reconstruction, which may have implications regarding graft choice and design of postoperative rehabilitation protocols for optimizing outcomes for patients undergoing ACL reconstruction. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 47 - 47
1 Dec 2020
Cicione C Papalia R Di Giacomo G Tilotta V Ambrosio L Russo F Vadalà G Denaro V
Full Access

Anterior cruciate ligament injury is the most common and economically costly sport injuries, frequently requiring expensive surgery and rehabilitation. Post-operative knee septic arthritis represents a serious complication with an incidence rate between 0.14% and 1.7%. A common practice to avoid septic arthritis is the “vancomycin wrap”, consisting in the soaking of the graft for 10–15 minutes within a sterile gauze swab previously saturated with 5 mg/mL vancomycin. Even though several studies have been conducted to investigate vancomycin toxicity on different musculoskeletal tissues or cells, little is known about the effect of such antimicrobial on tendon-derived cells. The aim of this study was to determine the in vitro toxicity of different concentrations of vancomycin at different time points on human primary tenocytes (hTCs). hTCs were isolated from hamstring grafts of patients undergoing anterior cruciate ligament reconstruction. After expansion, cells were treated with different concentrations of vancomycin (2.5, 5, 10, 25, 50 and 100 mg/mL) for 10, 15, 30 and 60 minutes. In vitro toxicity was evaluated measuring: metabolic activity through the reduction of 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT Assay); cytotoxicity (Live/Dead assay); and cell apoptosis (Annexin V apoptosis kit). The metabolic activity of hTCs was affected by vancomycin treatment starting from 10 mg/mL at all time points (p < 0.05) and dropped down at 100 mg/mL at all time points (0.05 < p < 0.001). Cells viability resulted to be unaffected only by 2.5 mg/mL vancomycin at all time points. Vancomycin resulted to be cytotoxic starting from 10 mg/mL after 15 minutes of treatment and at all higher concentrations under study at all time points. Cells died when treated with vancomycin concentrations higher than 5 mg/mL but not through apoptosis, as confirmed by negative staining for Annexin V. In our experimental conditions, vancomycin resulted to be toxic on hTCs at concentrations higher than 5 mg/mL. The use of this antibiotic on tendons to prevent infections could be useful and safe for resident cells if used at a concentration of 2.5 mg/mL up to 1 hour of treatment


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 79 - 79
1 Jan 2017
Zaffagnini S Signorelli C Bontempi M Bragonzoni L Raggi F Marchiori G Lopomo N Marcacci M
Full Access

Anterior cruciate ligament (acl) reconstruction is one of the most commonly performed procedures in orthopedics for acl injury. While literature suggest short-term good-to-excellent functional results, a significant number of long-term studies report unexplained early oa development, regardless type of reconstruction. The present study reports the feasibility analysis and development of a clinical protocol, integrating different methodologies, able to determine which acl reconstruction technique could have the best chance to prevent oa. It gives also clinicians an effective tool to minimize the incidence of early oa. A prospective clinical trial was defined to evaluate clinical outcome, biochemical changes in cartilage, biomechanical parameters and possible development of oa. The most common reconstruction techniques were selected for this study, including hamstring single-bundle, single-bundle with extraarticular tenodesis and anatomical double-bundle. Power analysis was performed in terms of changes at cartilage level measurable by mri with t2 mapping. A sample size of 42 patients with isolated traumatic acl injury were therefore identified, considering a possible 10% to follow-up. Subjects presenting skeletal immaturity, degenerative tear of acl, other potential risk factors of oa and previous knee surgery were excluded. Included patients were randomized and underwent one of the 3 specified reconstruction techniques. The patients were evaluated pre-operatively, intra-operatively and post-operatively at 4 and 18 months of follow-up. Clinical evaluation were performed at each time using subjective scores (koos) and generic health status (sf-12). The activity level were documented (marx) as well as objective function (ikdc). Preliminary results allow to verify kinematic patterns during active tasks, including level walking, stair descending and squatting using dynamic roentgen sterephotogrammetric analysis (rsa) methodology before and after the injured ligament reconstruction. Intra-operative kinematics was also available by using a dedicated navigation system, thus to verify knee laxity at the time of surgery. Additionally, non-invasive assessment was possible both before the reconstruction and during the whole follow-up period by using inertial sensors. Integrating 3d models with kinematic data, estimation of contact areas of stress patterns on cartilage was also possible. The presented integrate protocol allowed to acquired different types of information concerning clinical assessment, biochemical changes in cartilage and biomechanical parameters to identify which acl reconstruction could present the most chondroprotective behavior. Preliminary data showed all the potential of the proposed workflow. The study is on-going and final results will be shortly provided


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 72 - 72
1 Nov 2018
Lipperts M Gotink F van der Weegen W Theunissen K Meijer K Grimm B
Full Access

3D measurement of joint angles so far has only been possible using marker-based movement analysis, and therefore has not been applied in (larger scale) clinical practice (performance test) and even less so in the free field (activity monitoring). 3D joint angles could provide useful additional information in assessing the risk of anterior cruciate ligament injury using a vertical drop jump or in assessing knee range of motion after total knee arthroplasty. We developed a tool to measure dynamic 3D joint angles using 6 inertial sensors, attached to left and right shank, thigh and pelvis. The same sensors have been used for activity identification in a previous study. To validate the setup in a pilot study, we measured 3D knee and hip angles using the sensors and a Vicon movement lab simultaneously in 3 subjects. Subjects performed drop jumps, squats and ran on the spot. The mean error between Vicon and sensor measurement for the maximum joint angles was 3, 7 and 8 degrees for knee flexion, ad/abduction and rotation respectively, and 9, 7 and 10 degrees for hip flexion, ad/abduction and rotation respectively. No calibration movements were required. A major part of the inaccuracy was caused by soft tissue effects and can partly be resolved by improved sensor attachment. These pilot results show that it is feasible to measure 3D joint angles continuously using unobtrusive light-weight sensors. No movement lab is necessary and therefore the measurements can be done in a free field setting, e.g. at home or during training at a sport club. A more extensive validation study will be performed in the near future


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 89 - 89
1 Jan 2017
Zaffagnini S Signorelli C Raggi F Grassi A Roberti Di Sarsina T Bonanzinga T Lopomo N Marcacci M
Full Access

The Pivot-shift phenomenon (PS) is known to be one of the essential signs of functional insufficiency of the anterior cruciate ligament (ACL). To evaluate the dynamic knee laxity is very important to accurately diagnose ACL injury, to assess surgical reconstructive techniques, and to evaluate treatment approaches. However, the pivot-shift test remains a subjective clinical examination difficult to quantify. The aim of the present study is to validate the use of an innovative non-invasive device based on the use of an inertial sensor to quantify PS test. The validation was based on comparison with data acquired by a surgical navigation system. The surgeon intraoperatively performed the PS tests on 15 patients just before fixing the graft required for the ACL reconstruction. A single accelerometer and a navigation system simultaneously acquired the joint kinematics. An additional optical tracker set to the accelerometer has allowed to quantify the movement of the sensor. The tibial anteroposterior acceleration obtained with the navigation system was compared with the acceleration acquired by the accelerometer. It is therefore estimated the presence of any artifacts due to the soft tissue as the test-retest repositioning error in the positioning of the sensor. It was also examined, the repeatability of the acceleration parameters necessary for the diagnosis of a possible ACL lesion and the waveform of the output signal obtained during the test. Finally it has been evaluated the correlation between the two acceleration measurements obtained by the two sensors. The RMS (root mean square) of the error of test-retest positioning has reported a good value of 5.5 ± 2.9 mm. While the amounts related to the presence of soft tissue artifacts was equal to 4.9 ± 2.6 mm. It was also given a good intra-tester repeatability (Cronbach's alpha = 0.86). The inter-patient similarity analysis showed a high correlation in the acceleration waveform of 0.88 ± 0.14. Finally the measurements obtained between the two systems showed a good correlation (rs = 0.72, p<0.05). This study showed good reliability of the proposed scheme and a good correlation with the results of the navigation system. The proposed device is therefore to be considered a valid method for evaluating dynamic joint laxity


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 51 - 51
1 May 2017
Frame M
Full Access

Aim. The aim of this study is to outline the steps and techniques required to create a patient specific 3D printed guide for the accurate placement of the origin of the femoral tunnel for single bundle ACL reconstruction. Introduction. Placements of the femoral tunnels for ACL reconstruction have changed over the years. Most recently there has been a trend towards placing the tunnels in a more anatomic position. There has been subsequent debate as to where this anatomic position should be. The problem with any attempt at consensus over the placement of an anatomic landmark is that each patient has some variation in their positioning and therefore a fixed point for all has compromise for all as it is an average. Our aim was to attempt to make a cost effective and quick custom guide that could allow placement of the center of the patients’ newly created femoral tunnel in the mid position of their contralateral native ACL femoral footprint. Materials & Methods. We took a standard protocol MRI scan of a patient's knee without ACL injury transferred the DICOM files to a personal computer running OsiriX (Pixmeo, Geneva, Switzerland.) and analysed it for a series of specific anatomical landmarks. OsiriX is an image processing software dedicated to DICOM images. We marked the most posterior edge of the articular cartilage on the lateral wall of the notch (1), the most anterior edge of the articular cartilage of the lateral wall of the notch (2), the most inferior edge of the articular cartilage of the lateral wall of the notch (3) and the center of the femoral footprint of the native ACL. Distances were then calculated to determine the position relative to the three articular cartilage points of the center of the ACL footprint. These measurements and points were then utilised to create a 3D computer aided design (CAD) model of a custom guide. This was done using the 3D CAD program 123Design (Autodesk Ltd., Farnbourgh, Hampshire). This 3D model was then exported as an STL file suitable for 3D printing. The STL file was then uploaded to an online 3D printing service and the physical guide was created in transparent acrylic based photopolymer, PA220 plastic and 316L stainless steel. The models created were then measured using vernier calipers to confirm the accuracy of the final guides. Results. The MRI data showed point 1 (AP), point 2 (distal-ACL), point 3 (Ant-ACL) and point 4 (Post-ACL) at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the 3D CAD model, points 1, 2, 3 and 4 were at a distance of 59.83, 15, 45.8 and 13.9 respectively. For the PA220 plastic model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.48, 45.85 and 13.79 respectively. For the 316L stainless steel model, points 1, 2, 3 and 4 were at a distance of 59.79, 14.67, 45.64 and 13.48 respectively. Lastly, for the photopolymer model, points 1, 2, 3 and 4 were at a distance of 59.86, 14.2, 45.4 and 13.69 respectively. The p-value comparing MRI/CAD vs. PA220 was p=0.3753; for the comparison between MRI/CAD vs. 316L, p=0.0683; lastly for the comparison between MRI/CAD Vs. Photopolymer, p=0.3450. The models produced were accurate with no statistical difference in size and positioning of the center of the ACL footprint from the original computer model and to the position of the ACL from the MRI scans. The costs for the models 3D printed were £3.50 for the PA220 plastic, £15 for the transparent photopolymer and £25 for the 316L stainless steel. The time taken from MRI to delivery for the physical models was 7 days. Discussion. Articles regarding the creation of 3D printed custom ACL guides from the patients contralateral knee do not feature in current literature. There has been much research on custom guides for other orthopaedic procedures such as in total knee arthroplasty for the accurate placement of implants. There has also been research published on the creation of custom cutting jigs from CT for complex corrective osteotomy surgery. This study serves as the first step and a proof of concept for the accurate creation of patient specific 3D printed guides for the anatomical placement of the femoral tunnel for ACL reconstruction. The guides were easy to create and produce taking only a week and with a cost of between £3.50 and £25. The design of the guides was to allow the tip of a standard Chondro Pick (Arthrex inc., Naples, Florida.) (3mm) used to mark the starting point of the femoral tunnel to enter through the guide. The next step for this research is to create guides from cadaveric matched knees and utilise the guides to carry out the creation of the femoral tunnels and to analyse of the placement of the tunnel in relation to the contralateral knee


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 66 - 66
1 Mar 2013
Sparkes V Brophy R Sheeran L
Full Access

Movement dysfunction resulting in a knee valgus position during weight bearing activity is associated with increased risk of Anterior Cruciate Ligament injury and Patellofemoral Pain Syndrome especially in young active females. In clinical practice determining the critical knee flexion angle (CKFA) during a single leg squat (SLS) test is used to assess this dysfunction, yet its reliability is unknown. This study aimed to determine rater agreement in determining the presence of knee valgus movement (yes/no) during a SLS test in recreational females (n = 16, age 24.3 ±7.9 yrs, height 165.7±4.8m, mass 62.5±6.4kg) and the intra and inter-rater reliability of measuring CKFA using SiliconCoach™. Three experienced physiotherapists viewed 48 randomised SLS test videos. One physiotherapist repeated the viewing for test-retest analysis. Test-retest agreement for rating SLS test was acceptable (weighted kappa (k) = 0.667). Inter-rater agreement was moderate to substantial (weighted k = 0.284–0.613). Intra-rater reliability of CKFA was acceptable for all three raters (ICC>0.6). Inter-rater absolute reliability was below 5% of the mean CKFA (SEM 4.26 degrees). As previous research reports intra-rater agreement is better than inter-rater agreement when assessing movement dysfunction during functional activity via visual rating. Intra-rater within session and between session reliability for measuring the CKFA using SiliconCoach™ was acceptable and better than inter-rater reliability. Further research is needed to assess the concurrent and construct validity of the protocols used in this study. It is recommended that qualitative research be performed to identify factors that affect physiotherapist's rating of functional activities


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 1 | Pages 129 - 133
1 Jan 2006
Lee SY Miwa M Sakai Y Kuroda R Niikura T Kurosaka M

We have investigated whether cells derived from haemarthrosis caused by injury to the anterior cruciate ligament could differentiate into the osteoblast lineage in vitro. Haemarthroses associated with anterior cruciate ligament injuries were aspirated and cultured. After treatment with β-glycerophosphate, ascorbic acid and dexamethasone or 1,25 (OH). 2. D. 3. , a significant increase in the activity of alkaline phosphatase was observed. Matrix mineralisation was demonstrated after 28 days and mRNA levels in osteoblast-related genes were enhanced. Our results suggest that the haemarthrosis induced by injury to the anterior cruciate ligament contains osteoprogenitor cells and is a potential alternative source for cell-based treatment in such injury


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 32 - 32
1 May 2012
Jemmett P Roberts H Paisey S Wilson C Mason D
Full Access

Meniscal tears commonly occur after a traumatic twisting injury to the knee (acute) or can form over time (degenerate). Symptoms include pain, swelling, and ‘locking’ of the knee. These symptoms are also commonly associated with osteoarthritis (OA). In some cases of OA, degenerative meniscal tears can also be present making it difficult to determine the cause of symptoms. Furthermore, acute meniscal lesions may be associated with early stage OA but often no radiological signs are evident. Many metabolites associated with joint disorders are released into the synovial fluid providing a real-time snap shot of joint pathology. The ability to examine concentrations of specific metabolites within synovial fluid could provide invaluable clinical information about the cause and stage of joint pathology. We have tested the hypothesis that ‘high resolution 1H-NMR can discriminate between osteoarthritic and meniscal tear-related metabolites within human synovial fluids and aid in clinical diagnosis.’. Method. Synovial fluid samples have been obtained during arthroscopy or knee replacement from patients with varying degrees of joint pathology (cartilage graded 0-4; meniscal tears classified as acute or degenerative). Samples were also taken from patients undergoing Anterior Cruciate Ligament (ACL) reconstruction with no additional pathology. Samples were analysed using 500 MHz 1H NMR spectroscopy. Chemical shifts were referenced to known concentration NMR internal standard (TSP), peaks identified by reference to published synovial fluid NMR spectra (1) and peak integrals measured using the Bruker software Topspin 2.0. Results. Spectroscopy revealed a number of differences in metabolites between OA, meniscal tear and ACL pathologies. These included significantly increased concentrations of glutamate, n-acetyl glycoprotein and β-hydroxybutyrate in OA (n=10) and acute meniscal tears (n=6) compared to ACL samples (p<0.05, T-test, n=6). Specific metabolites were also able to discriminate between OA with no meniscal tear and OA with meniscal tear synovial fluids. For example, concentrations of n-acetyl glycoproteins, glutamate and CH3 lipids were significantly increased in OA without tears (n=10) compared to OA plus meniscal tears (n=12); conversely ceramide concentrations were significantly increased in OA plus tears compared to OA only samples (p<0.05, T-test). Discussion. Our preliminary data indicate that the metabolic profiles of synovial fluid differ between OA, OA plus meniscal tear and ACL injuries. OA samples have increased concentrations of n-acetyl glycoproteins which can be indicative of degradative products from cartilage matrix such as hyaluronic acid. The increased concentrations of glutamate in OA may reflect activation of nociceptive, degradative and inflammatory processes (2). These metabolite concentrations were also increased in acute meniscal tear synovial fluids, which may reflect early signs of cartilage pathology. The differing levels of metabolites seen in OA alone compared to OA with meniscal tears may ultimately be a useful indicator of whether cartilage or meniscal pathology predominates within the joint