Advertisement for orthosearch.org.uk
Results 1 - 20 of 86
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 91 - 91
1 Mar 2021
Martin R Critchley R Anjum S
Full Access

Neck of femur fractures are a common presentation and certain patients can be managed with a total hip replacement. To receive a total hip replacement the pelvic X-rays should be templated as per AO guidelines and a common way this is performed is by including a calibration marker on the X-ray. The aim of this study is to assess and improve upon the use of the calibration marker. Details of patients admitted with a neck of femur fracture from January 1st 2018 until December 31st 2018 were gathered and used to review each initial X-ray and determine if a calibration marker was included. 376 patients were admitted with a neck of femur fracture over the one year period. 36% of patients did not have a calibration marker on their initial pelvic X-ray and 11% did not have a chest X ray. 215 patients had an intracapsular fracture and 39 went on to have a total hip replacement. 12 patients were lacking a calibration marker on their original X ray and required a repeat X ray. After a poster was placed in the radiographer booth acting as a visual aid, the use of a calibration marker improved from 62% to 70%. Calibration markers are useful tools which can aid the pre-operative planning for hip replacement surgeries shortening operative time, increase precision and reduce prosthetic loosening, lowers the risk of peri-prosthetic fractures, reduce leg length discrepancy and ensure the required implants are available. If a marker is not included on the initial X-rays, and a patient has a neck of femur fracture which requires a joint replacement, they may have to have additional X-rays performed as was the case for 12 patients in this study. This process leads to possible delays in surgery, additional radiation and increased healthcare costs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 1 - 1
1 May 2017
Malahias M Babis G Kaseta M Chytas D Kazas S Nikolaou V
Full Access

Introduction. We investigated whether grey scale early ultrasonography could be used for the accurate initial diagnosis of non displaced occult scaphoid fractures. Methods. This is a prospective blind clinical study that includes 36 patients that came to the emergency room with suspected clinical symptoms for scaphoid fracture but negative initial X-ray's. After that, a high resolution ultrasonography (without Doppler) was performed. Both wrists of each patient were examined, for comparison. After 14 days, new X-rays were performed, which compared to the early sonographic results of the patients. Results. 25 out of the 36 patients that were included in the study found with subperiosteal hematoma, while 11 of them had also cortical discontinuity. Besides, follow-up X-rays were diagnostic of fracture in 22 patients. 7 patients were ultrasound-positive for fracture but their late X-ray's remained negative, while 4 patients were ultrasound-negative with positive X-ray's. We performed a CT scan on these 11 patients, where we found early ultrasound's sensitivity: 87.5%, specificity: 75%, positive prognostic value: 84% and negative prognostic value: 72%. On the other hand, late X-ray's had sensitivity: 87.5%, specificity: 91%, positive prognostic value: 95% and negative prognostic value: 78% in the detection of occult fractures. Conclusion. The use of early scaphoid ultrasound in the E.R. is valuable in the hands of the orthopaedic surgeon and decongests the radiology department and the national health system from further specific and expensive imaging studies. So, this examination offers the possibility to reduce the time of diagnosis of these occult fractures, so as to provide early and correct treatment. Level of Evidence. II


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 5 - 5
14 Nov 2024
Panagiota Glynou S Musbahi O Cobb J
Full Access

Introduction. Knee arthroplasty (KA), encompassing Total Knee Replacement (TKR) and Unicompartmental Knee Replacement (UKR), is one of the most common orthopedic procedures, aimed at alleviating severe knee arthritis. Postoperative KA management, especially radiographic imaging, remains a substantial financial burden and lacks standardised protocols for its clinical utility during follow-up. Method. In this retrospective multicentre cohort study, data were analysed from January 2014 to March 2020 for adult patients undergoing primary KA at Imperial NHS Trust. Patients were followed over a five-year period. Four machine learning models were developed to evaluate if post-operative X-ray frequency can predict revision surgery. The best-performing model was used to assess the risk of revision surgery associated with different number of X-rays. Result. The study assessed 289 knees with a 2.4% revision rate. The revision group had more X-rays on average than the primary group. The best performing model was Logistic Regression (LR), which indicated that each additional X-ray raised the revision risk by 52% (p<0.001). Notably, having four or more X-rays was linked to a three-fold increase in risk of revision (OR=3.02; p<0.001). Our results align with the literature that immediate post-operative X-rays have limited utility, making the 2nd post-operative X-ray of highest importance in understanding the patient's trajectory. These insights can enhance management by improving risk stratification for patients at higher revision surgery risk. Despite LR being the best-performing model, it is limited by the dataset's significant class imbalance. Conclusion. X-ray frequency can independently predict revision surgery. This study provides insights that can guide surgeons in evidence-based post-operative decision-making. To use those findings and influence post-operative management, future studies should build on this predictive model by incorporating a more robust dataset, surgical indications, and X-ray findings. This will allow early identification of high-risk patients, allowing for personalised post-operative recommendations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 63 - 63
11 Apr 2023
Pastor T Knobe M Kastner P Souleiman F Pastor T Gueorguiev B Windolf M Buschbaum J
Full Access

Freehand distal interlocking of intramedullary nails is technical demanding and prone to handling issues. It requires the surgeon to precisely place a screw through the nail under x-ray. If not performed accurately it can be a time consuming and radiation expensive procedure. The aims of this study were to assess construct and face validity of a new training device for distal interlocking of intramedullary nails. 53 participants (29 novices and 24 experts) were included. Construct validity was evaluated by comparing simulator metrics (number of x-rays, nail hole roundness, drill tip position and accuracy of the drilled hole) between experts and novices. Face validity was evaluated by means of a questionnaire concerning training potential and quality of simulated reality using a 7-point Likert scale (range 1-7). Mean realism of the training device was rated 6.3 (range 4-7) and mean training potential as well as need for distal interlocking training was rated 6.5 (range 5-7) with no significant differences between experts and novices, p≥0.236. All participants stated that the simulator is useful for procedural training of distal nail interlocking, 96% would like to have it at their institution and 98% would recommend it to their colleagues. Total number of x-rays were significantly higher for novices (20.9±6.4 vs. 15.5±5.3), p=0.003. Successful task completion (hit the virtual nail hole with the drill) was significantly higher in experts (p=0.04; novices hit: n=12; 44,4%; experts hit: n=19; 83%). The evaluated training device for distal interlocking of intramedullary nails yielded high scores in terms of training capability and realism. Furthermore, construct validity was established as it reliably discriminates between experts and novices. Participants see a high further training potential as the system may be easily adapted to other surgical task requiring screw or pin position with the help of x-rays


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 136 - 136
4 Apr 2023
Renteria C Wasserstein D Tomescu S Razmjou H
Full Access

The primary purpose of this longitudinal study was to examine the impact of physical and mental well-being on a successful return to work after cartilage or ligament knee injury. A secondary purpose was to examine the effectiveness of our program regarding ordering imaging (plain X-rays, US, MRI, CT scan), and the impact that costly investigations made in clinical management. Workers who had sustained a work-related knee injury and were assessed at the lower extremity specialty clinic of our hospital program were followed up until they were discharged. All patients completed the numeric pain rating scale (NPRS), the Lower Extremity Functional Scale (LEFS), and the Hospital Anxiety and Depression Scale (HADS) on the initial assessment and at final follow-up. We included 30 patients, mean age, 50(9), 11(37%) females, 19(63%) males. The most common mechanisms of injury were twisting (13, 45%) and falls (12, 41%). The knee injuries included 10 anterior collateral ligament (ACL), 3 posterior collateral ligament (PCL), 19 medical and lateral ligament injuries, and 22 meniscus injuries with some injuries overlapping. Ten patients (30%) underwent surgery (8 meniscectomy, two ligamentous repairs). Patients showed improvement in pain scores (p<0.0001) and the LEFS scores (p=0.004). Seventeen patients (57%) returned to full-time work and 11 (37%) were not working at the time of discharge with one patient performing part-time work, and one on re-training. Higher levels of pre (p=0.02) and post-treatment (p=0.03) depression and post-treatment anxiety (p=0.02) had a negative impact on a successful return to work. Most clients had proper investigations ordered by their family physicians in the community (24 plain x-rays, 11 US, and 21 MRI). Our team ordered only 6 plain x-rays and 6 new MRI. We found significant improvement in pain and disability in injured workers who received an expedited multidisciplinary care. Anxiety and depression were the most important predictors of poorer recovery and a less successful work status. The judicious use of costly imaging is expected to reduce the overall health care cost of an injury, while providing new important information such as adding a new diagnosis or changing the management


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 98 - 98
11 Apr 2023
Williams D Chapman G Esquivel L Brockett C
Full Access

To be able to assess the biomechanical and functional effects of ankle injury and disease it is necessary to characterise healthy ankle kinematics. Due to the anatomical complexity of the ankle, it is difficult to accurately measure the Tibiotalar and Subtalar joint angles using traditional marker-based motion capture techniques. Biplane Video X-ray (BVX) is an imaging technique that allows direct measurement of individual bones using high-speed, dynamic X-rays. The objective is to develop an in-vivo protocol for the hindfoot looking at the tibiotalar and subtalar joint during different activities of living. A bespoke raised walkway was manufactured to position the foot and ankle inside the field of view of the BVX system. Three healthy volunteers performed three gait and step-down trials while capturing Biplane Video X-Ray (125Hz, 1.25ms, 80kVp and 160 mA) and underwent MR imaging (Magnetom 3T Prisma, Siemens) which were manually segmented into 3D bone models (Simpleware Scan IP, Synopsis). Bone position and orientation for the Talus, Calcaneus and Tibia were calculated by manual matching of 3D Bone models to X-Rays (DSX Suite, C-Motion, Inc.). Kinematics were calculated using MATLAB (MathWorks, Inc. USA). Pilot results showed that for the subtalar joint there was greater range of motion (ROM) for Inversion and Dorsiflexion angles during stance phase of gait and reduced ROM for Internal Rotation compared with step down. For the tibiotalar joint, Gait had greater inversion and internal rotation ROM and reduced dorsiflexion ROM when compared with step down. The developed protocol successfully calculated the in-vivo kinematics of the tibiotalar and subtalar joints for different dynamic activities of daily living. These pilot results show the different kinematic profiles between two different activities of daily living. Future work will investigate translation kinematics of the two joints to fully characterise healthy kinematics


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 125 - 125
4 Apr 2023
Heylen J Macdonald N Larsson E Moon K Vaughan A Owens R
Full Access

In current practice in the UK there are three main approaches to investigating suspected scaphoid fractures not seen on initial plain film x-rays. Early MRI of all cases. Review all cases in clinic at two weeks with repeat x-rays. Hybrid model. Virtual Fracture Clinic (VFC) triage to reduce those who are seen in clinic at two weeks by:. ∘. Organising early MRI for those with high-risk presentation. ∘. Discharging those with an alternative more likely diagnosis. Our unit uses the VFC model. We aimed to evaluate its efficiency, safety, clinical outcomes and economic viability. All patients attending the emergency department with either a confirmed or suspected scaphoid fracture between March and December 2020 were included (n=305). Of these 297 were referred to the VFC: 33 had a confirmed fracture on x-ray and 264 had a suspected fracture. Of the suspected fractures reviewed in VFC 14% had an MRI organised directly owing to a high-risk presentation, 79% were brought for fracture clinic review and 17% discharged with an alternative diagnosis such as osteoarthritis. Of those subsequently reviewed in fracture clinic at two weeks: 9% were treated as scaphoid fractures (based on clinical suspicion and repeat x-rays), 17% had MRI or CT imaging organised, 5% did not attend and 69% were discharged. Overall, 17% of cases initially triaged, had further imaging – 41 MRIs and 5 CTs. MRI detected: 5% scaphoid fracture, 17% other fracture, 24% bone contusion, complete ligament tear 10%, partial ligament tear 39% and normal study 10%. The results of MRI minimally affected management. 3 patients were taken out of plaster early, 1 patient was immobilized who was not previously and no patients underwent operative management. In the following 12-month period one patient re-presented with a hand or wrist issue. This approach avoided 218 MRIs, equating to £24000 and 109 hours of scanner time. VFC triage and selective use of MRI scanning is a safe, efficient and cost-effective method for the management suspected scaphoid fractures. This can be implemented in units without the resource to MRI all suspected scaphoid fractures from the emergency department


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 54 - 54
17 Nov 2023
Bishop M Zaffagnini S Grassi A Fabbro GD Smyrl G Roberts S MacLeod A
Full Access

Abstract. Background. Distal femoral osteotomy is an established successful procedure which can delay the progression of arthritis and the need for knee arthroplasty. The surgery, however, is complex and lengthy and consequently it is generally the preserve of highly experienced specialists and thus not widely offered. Patient specific instrumentation is known to reduce procedural complexity, time, and surgeons’ anxiety levels. 1. in proximal tibial osteotomy procedures. This study evaluated a novel patient specific distal femoral osteotomy procedure (Orthoscape, Bath, UK) which aimed to use custom-made implants and instrumentation to provide a precision correction while also simplifying the procedure so that more surgeons would be comfortable offering the procedure. Presenting problem. Three patients (n=3) with early-stage knee arthritis presented with valgus malalignment, the source of which was predominantly located within the distal femur, rather than intraarticular. Using conventional techniques and instrumentation, distal femoral knee osteotomy cases typically require 1.5–2 hours surgery time. The use of bi-planar osteotomy cuts have been shown to improve intraoperative stability as well as bone healing times. 2. This normally also increases surgical complexity; however, multiple cutting slots can be easily incorporated into patient specific instrumentation. Clinical management. All three cases were treated at a high-volume tertiary referral centre (Istituto Ortopedico Rizzoli, Bologna) using medial closing wedge distal femoral knee osteotomies by a team experienced in using patient specific osteotomy systems. 3. Virtual surgical planning was conducted using CT-scans and long-leg weight-bearing x-rays (Orthoscape, Bath, UK). Patient specific surgical guides and custom-made locking plates were design for each case. The guides were designed to allow temporary positioning, drilling and bi-planar saw-cutting. The drills were positioned such that the drills above and below the osteotomy became parallel on closing following osteotomy wedge removal. This gave reassurance of the achieved correction allowed the plate to be located precisely over the drills. All screw lengths were pre-measured. Discussion. The surgical time reduced to approximately 30 minutes by the third procedure. It was evident that surgical time was saved because no intraoperative screw length measurements were required, relatively few x-rays were used to confirm the position of the surgical guide, and the use of custom instrumentation significantly reduced the surgical inventory. The reduced invasiveness and ease of surgery may contribute to faster patient recovery compared to conventional techniques. The final post-operative alignment was within 1° of the planned alignment in all cases. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 30 - 30
17 Nov 2023
Swain L Holt C Williams D
Full Access

Abstract. Objectives. Investigate Magnetic Resonance Imaging (MRI) as an alternative to Computerised Tomography (CT) when calculating kinematics using Biplane Video X-ray (BVX) by quantifying the accuracy of a combined MRI-BVX methodology by comparing with results from a gold-standard bead-based method. Methods. Written informed consent was given by one participant who had four tantalum beads implanted into their distal femur and proximal tibia from a previous study. Three-dimensional (3D) models of the femur and tibia were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). Anatomical Coordinate Systems (ACS) were applied to the bone models using automated algorithms. 1. The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (60 FPS, 1.25 ms pulse width) was recorded whilst the participant performed a lunge. The beads were tracked, and the ACS position of the femur and tibia were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Using the principles defined by Grood and Suntay. 2. , 6 DOF kinematics of the tibiofemoral joint were calculated (MATLAB, MathWorks). The mean difference and STD between these two sets of kinematics were calculated. Results. The absolute mean femur and tibia ACS position differences (Table 1) between the bead and image-registered poses were found to be within 0.75mm for XYZ, with all STD within ±0.5mm. Mean rotation differences for both bones were found to be within 0.2º for XYZ (Table 1). The absolute mean tibiofemoral joint translations (Table 1) were found to be within ±0.7mm for all DOF, with the smallest absolute mean in compression-distraction. The absolute mean tibiofemoral rotations were found to be within 0.25º for all DOF (Table 1), with the smallest mean was found in abduction-adduction. The largest mean and STD were found in internal-external rotation due to the angle of the X-rays relative to the joint movement, increasing the difficulty of manual image registration in that plane. Conclusion. The combined MRI-BVX method produced bone pose and tibiofemoral kinematics accuracy similar to previous CT results. 3. This allows for confidence in future results, especially in clinical applications where high accuracy is needed to understand the effects of disease and the efficacy of surgical interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 119 - 119
4 Apr 2023
Jalal M Wallace R Peault B Simpson H
Full Access

To test and evaluate the effectiveness of local injection of autologous fat-derived mesenchymal stem cells (MSCs) into fracture site to prevent non-union in a clinically relevant model. 5 male Wistar rats underwent the same surgical procedure of inducing non-union. A mid-shaft tibial osteotomy was made with 1mm non-critical gap. Periosteum was stripped around the two fracture ends. Then, the fracture was fixed by ante-grade intramedullary nail. The non-critical gap was maintained by a spacer with minimal effect on the healing surface area. At the same surgical time, subcutaneous fat was collected from the ipsilateral inguinal region and stem cells were isolated and cultured in vitro. Within three weeks postoperatively, the number of expanded stem cells reached 5×10. 6. and were injected into the fracture site. Healing was followed up for 8 weeks and the quality was measured by serial x-rays, microCT, mechanical testing and histologically. Quality of healing was compared with that of previously published allogenic, xenogeneic MSCs and Purified Buffered Saline (PBS) controls. All the five fractures united fully after 8 weeks. There was a progressive increase in the callus radiopacity during the eight-week duration, the average radiopacity in the autologous fat-MSC injected group was significantly higher than that of the allogeneic MSCs, xenogeneic MSCs and the control group, P < 0.0001 for treatment, time after injection, and treatment-time interaction (two-way repeated measure ANOVA). MicroCT, mechanical testing and histology confirmed radiological findings. The autologous fat-MSCs are effective in prevention of atrophic non-union by stimulation of the healing process leading to a solid union. The quality and speed of repair are higher than those of the other types of cell transplantation tested


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 31 - 31
2 Jan 2024
Ernst M Windolf M Varjas V Gehweiler D Gueorguiev-Rüegg B Richards R
Full Access

In absence of available quantitative measures, the assessment of fracture healing based on clinical examination and X-rays remains a subjective matter. Lacking reliable information on the state of healing, rehabilitation is hardly individualized and mostly follows non evidence-based protocols building on common guidelines and personal experience. Measurement of fracture stiffness has been demonstrated as a valid outcome measure for the maturity of the repair tissue but so far has not found its way to clinical application outside the research space. However, with the recent technological advancements and trends towards digital health care, this seems about to change with new generations of instrumented implants – often unfortunately termed “smart implants” – being developed as medical devices. The AO Fracture Monitor is a novel, active, implantable sensor system designed to provide an objective measure for the assessment of fracture healing progression (1). It consists of an implantable sensor that is attached to conventional locking plates and continuously measures implant load during physiological weight bearing. Data is recorded and processed in real-time on the implant, from where it is wirelessly transmitted to a cloud application via the patient's smartphone. Thus, the system allows for timely, remote and X-ray free provision of feedback upon the mechanical competence of the repair tissue to support therapeutic decision making and individualized aftercare. The device has been developed according to medical device standards and underwent extensive verification and validation, including an in-vivo study in an ovine tibial osteotomy model, that confirmed the device's capability to depict the course of fracture healing as well as its long-term technical performance. Currently a multi-center clinical investigation is underway to demonstrate clinical safety of the novel implant system. Rendering the progression of bone fracture healing assessable, the AO Fracture Monitor carries potential to enhance today's postoperative care of fracture patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 59 - 59
4 Apr 2023
MacLeod A Roberts S Mandalia V Gill H
Full Access

Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔP. s,. based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived:. ΔP. s. =sin. -1. (sin α sin θ). The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 39 - 39
2 Jan 2024
Pastor T Cattaneo E Pastor T Gueorguiev B Windolf M Buschbaum J
Full Access

Freehand distal interlocking of intramedullary nails remains a challenging task. If not performed correctly it can be a time consuming and radiation expensive procedure. Recently, the AO Research Institute developed a new training device for Digitally Enhanced Hands-on Surgical Training (DEHST) that features practical skills training augmented with digital technologies, potentially improving surgical skills needed for distal interlocking. Aim of the study: To evaluate weather training with DEHST enhances the performance of novices without surgical experience in free-hand distal nail interlocking compared to a non-trained group of novices. 20 novices were assigned in two groups and performed distal interlocking of a tibia nail in an artificial bone model. Group 1: DEHST trained novices (virtual locking of five nail holes during one hour of training). Group 2: untrained novices without DEHST training. Time, number of x-rays, nail hole roundness, critical events and success rates were compared between the groups. Time to complete the task (sec.) and x-ray exposure (µGcm2) were significantly lower in Group1 414.7 (290–615) and 17.8 (9.8–26.4) compared to Group2 623.4 (339–1215) and 32.6 (16.1–55.3); p=0.041 and 0.003. Perfect circle roundness (%) was 95.0 (91.1–98.0) in Group 1 and 80.8 (70.1–88.9) in Group 2; p<0.001. In Group 1 90% of the participants achieved successful completion of the task (hit the nail with the drill), whereas only 60% of the participants in group 2 achieved this; p=0.121. Training with DEHST significantly enhances the performance of novices without surgical experience in distal interlocking of intramedullary nails. Besides radiation exposure and operation time the com-plication rate during the operation can be significantly reduced


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 12 - 12
11 Apr 2023
Swain L Shillabeer D Wyatt H Jonkers I Holt C Williams D
Full Access

Biplane video X-ray (BVX) – with models segmented from magnetic resonance imaging (MRI) – is used to directly track bones during dynamic activities. Investigating tibiofemoral kinematics helps to understand effects of disease, injury, and possible interventions. Develop a protocol and compare in-vivo kinematics during loaded dynamic activities using BVX and MRI. BVX (60 FPS) was captured whilst three healthy volunteers performed three repeats of lunge, stair ascent and gait. MRI scans were performed (Magnetom 3T Prisma, Siemens). 3D bone models of the tibia and femur were segmented (Simpleware Scan IP, Synopsis). Bone poses were obtained by manually matching bone models to X-rays (DSX Suite, C-Motion Inc.). Mean range of motion (ROM) of the contact points on the medial and lateral tibial plateau were calculated using custom MATLAB code (MathWorks). Results were filtered using an adaptive low pass Butterworth filter (Frequency range: 5-29Hz). Gait and Stair ascent activities from one participant's data showed increased ROM for medial-lateral (ML) translation in the medial compartment but decreased ROM in anterior-posterior (AP) translation when comparing against the same translations on the lateral compartment of the tibial plateau. Lunge activity showed increased ROM for both ML and AP translation in the medial compartment when compared with the lateral compartment. These results highlight the variability in condylar translations between different activities. Understanding healthy in-vivo kinematics across different activities allows the determination of suitable activities to best investigate the kinematic changes due to disease or injury and assess the efficacy of different interventions. Acknowledgements: This research was supported by the Engineering and Physical Sciences Research Council (EPSRC) doctoral training grant (EP/T517951/1)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 136 - 136
11 Apr 2023
Glatt V Woloszyk A Agarwal A
Full Access

Our previous rat study demonstrated an ex vivo-created “Biomimetic Hematoma” (BH) that mimics the intrinsic structural properties of normal fracture hematoma, consistently and efficiently enhanced the healing of large bone defects at extremely low doses of rhBMP-2 (0.33 μg). The aim of this study was to determine if an extremely low dose of rhBMP-2 delivered within BH can efficiently heal large bone defects in goats. Goat 2.5 cm tibial defects were stabilized with circular fixators, and divided into groups (n=2-3): 2.1 mg rhBMP-2 delivered on an absorbable collagen sponge (ACS); 52.5 μg rhBMP-2 delivered within BH; and an empty group. BH was created using autologous blood with a mixture of calcium and thrombin at specific concentrations. Healing was monitored with X-rays. After 8 weeks, femurs were assessed using microCT. Using 2.1 mg on ACS was sufficient to heal 2.5 cm bone defects. Empty defects resulted in a nonunion after 8 weeks. Radiographic evaluation showed earlier and more robust callus formation with 97.5 % (52.5 μg) less of rhBMP-2 delivered within the BH, and all tibias were fully bridged at 3 weeks. The bone mineral density was significantly higher in defects treated with BH than with ACS. Defects in the BH group had smaller amounts of intramedullary and cortical trabeculation compared to the ACS group, indicating advanced remodeling. The results confirm that the delivery of rhBMP-2 within the BH was much more efficient than on an ACS. Not only did the large bone defects heal consistently with a 40x lower dose of rhBMP-2, but the quality of the defect regeneration was also superior in the BH group. These findings should significantly influence how rhBMP-2 is delivered clinically to maximize the regenerative capacity of bone healing while minimizing the dose required, thereby reducing the risk of adverse effects


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 11 - 11
17 Apr 2023
Inacio J Schwarzenberg P Yoon R Kantzos A Malige A Nwachuku C Dailey H
Full Access

The objective of this study was to use patient-specific finite element modeling to measure the 3D interfragmentary strain environment in clinically realistic fractures. The hypothesis was that in the early post-operative period, the tissues in and around the fracture gap can tolerate a state of strain in excess of 10%, the classical limit proposed in the Perren strain theory. Eight patients (6 males, 2 females; ages 22–95 years) with distal femur fractures (OTA/AO 33-A/B/C) treated in a Level I trauma center were retrospectively identified. All were treated with lateral bridge plating. Preoperative computed tomography scans and post-operative X-rays were used to create the reduced fracture models. Patient-specific materials properties and loading conditions (20%, 60%, and 100% body weight (BW)) were applied following our published method.[1]. Elements with von Mises strains >10% are shown in the 100% BW loading condition. For all three loading scenarios, as the bridge span increased, so did the maximum von Mises strain within the strain visualization region. The average gap closing (Perren) strain (mean ± SD) for all patient-specific models at each body weight (20%, 60%, and 100%) was 8.6% ± 3.9%, 25.8% ± 33.9%, and 39.3% ± 33.9%, while the corresponding max von Mises strains were 42.0% ± 29%, 110.7% ± 32.7%, and 168.4% ± 31.9%. Strains in and around the fracture gap stayed in the 2–10% range only for the lowest load application level (20% BW). Moderate loading of 60% BW and above caused gap strains that far exceeded the upper limit of the classical strain rule (<10% strain for bone healing). Since all of the included patients achieved successful unions, these findings suggest that healing of distal femur fractures may be robust to localized strains greater than 10%


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 57 - 57
14 Nov 2024
Birkholtz F Eken M Boyes A Engelbrecht A
Full Access

Introduction. With advances in artificial intelligence, the use of computer-aided detection and diagnosis in clinical imaging is gaining traction. Typically, very large datasets are required to train machine-learning models, potentially limiting use of this technology when only small datasets are available. This study investigated whether pretraining of fracture detection models on large, existing datasets could improve the performance of the model when locating and classifying wrist fractures in a small X-ray image dataset. This concept is termed “transfer learning”. Method. Firstly, three detection models, namely, the faster region-based convolutional neural network (faster R-CNN), you only look once version eight (YOLOv8), and RetinaNet, were pretrained using the large, freely available dataset, common objects in context (COCO) (330000 images). Secondly, these models were pretrained using an open-source wrist X-ray dataset called “Graz Paediatric Wrist Digital X-rays” (GRAZPEDWRI-DX) on a (1) fracture detection dataset (20327 images) and (2) fracture location and classification dataset (14390 images). An orthopaedic surgeon classified the small available dataset of 776 distal radius X-rays (Arbeidsgmeischaft für Osteosynthesefragen Foundation / Orthopaedic Trauma Association; AO/OTA), on which the models were tested. Result. Detection models without pre-training on the large datasets were the least precise when tested on the small distal radius dataset. The model with the best accuracy to detect and classify wrist fractures was the YOLOv8 model pretrained on the GRAZPEDWRI-DX fracture detection dataset (mean average precision at intersection over union of 50=59.7%). This model showed up to 33.6% improved detection precision compared to the same models with no pre-training. Conclusion. Optimisation of machine-learning models can be challenging when only relatively small datasets are available. The findings of this study support the potential of transfer learning from large datasets to improve model performance in smaller datasets. This is encouraging for wider application of machine-learning technology in medical imaging evaluation, including less common orthopaedic pathologies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 50 - 50
17 Nov 2023
Williams D Ward M Kelly E Shillabeer D Williams J Javadi A Holsgrove T Meakin J Holt C
Full Access

Abstract. Objectives. Spinal disorders such as back pain incur a substantial societal and economic burden. Unfortunately, there is lack of understanding and treatment of these disorders are further impeded by the inability to assess spinal forces in vivo. The aim of this project is to address this challenge by developing and testing a novel image-driven approach that will assess the forces in an individual's spine in vivo by incorporating information acquired from multimodal imaging (magnetic resonance imaging (MRI) and biplane X-rays) in a subject-specific model. Methods. Magnetic resonance and biplane X-ray imaging are used to capture information about the anatomy, tissues, and motion of an individual's spine as they perform a range of everyday activities. This information is then utilised in a subject-specific computational model based on the finite element method to predict the forces in their spine. The project is also utilising novel machine learning algorithms and in vitro, six-axis mechanical testing on human, porcine and bovine samples to develop and test the modelling methods rigorously. Results & Discussion. MRI sequences have been identified that provide high-quality image data and information on different tissue types which will be used to predict subject-specific disc properties. In-vivo protocols to capture motion analysis, EMG muscle activity, and video X-rays of the spine have been designed with planned data collection of 15 healthy volunteers. Preliminary modelling work has evaluated potential machine learning approaches and quantified the sensitivity of the models developed to material properties. Conclusion. The development and testing of these image-driven subject-specific spine models will provide a new tool for determining forces in the spine. It will also provide new tools for measuring and modelling spine movement and quantifying the properties of the spinal tissues. Acknowledgments. Funding from the EPSRC: EP/V036602/1 (Meakin, Holsgrove & Javadi) and EP/V032275/1 (Holt & Williams). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 50 - 50
14 Nov 2024
Birkholtz F Eken M Swanevelder M Engelbrecht A
Full Access

Introduction. Inaccurate identification of implants on X-rays may lead to prolonged surgical duration as well as increased complexity and costs during implant removal. Deep learning models may help to address this problem, although they typically require large datasets to effectively train models in detecting and classifying objects, e.g. implants. This can limit applicability for instances when only smaller datasets are available. Transfer learning can be used to overcome this limitation by leveraging large, publicly available datasets to pre-train detection and classification models. The aim of this study was to assess the effectiveness of deep learning models in implant localisation and classification on a lower limb X-ray dataset. Method. Firstly, detection models were evaluated on their ability to localise four categories of implants, e.g. plates, screws, pins, and intramedullary nails. Detection models (Faster R-CNN, YOLOv5, EfficientDet) were pre-trained on the large, freely available COCO dataset (330000 images). Secondly, classification models (DenseNet121, Inception V3, ResNet18, ResNet101) were evaluated on their ability to classify five types of intramedullary nails. Localisation and classification accuracy were evaluated on a smaller image dataset (204 images). Result. The YOLOv5s model showed the best capacity to detect and distinguish between different types of implants (accuracy: plate=82.1%, screw=72.3%, intramedullary nail=86.9%, pin=79.9%). Screw implants were the most difficult implant to detect, likely due to overlapping screw implants visible in the image dataset. The DenseNet121 classification model showed the best performance in classifying different types of intramedullary nails (accuracy=73.7%). Therefore, a deep learning model pipeline with the YOLOv5s and DenseNet121 was proposed for the most optimal performance of automating implants localisation and classification for a relatively small dataset. Conclusion. These findings support the potential of deep learning techniques in enhancing implant detection accuracy. With further development, AI-based implant identification may benefit patients, surgeons and hospitals through improved surgical planning and efficient use of theatre time


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 9 - 9
17 Apr 2023
Mortimer J Tamaddon M Liu C
Full Access

Rotator cuff tears are common, with failure rates of up to 94% for large and massive tears. 1. For such tears, reattachment of the musculotendinous unit back to bone is problematic, and any possible tendon-bone repair heals through scar tissue rather than the specially adapted native enthesis. We aim to develop and characterise a novel soft-hard tissue connector device, specific to repairing/bridging the tendon-bone injury in significant rotator cuff tears, employing decellularised animal bone partially demineralised at one end for soft tissue continuation. Optimisation samples of 15×10×5mm. 3. , trialled as separate cancellous and cortical bone samples, were cut from porcine femoral condyles and shafts, respectively. Samples underwent 1-week progressive stepwise decellularisation and a partial demineralisation process of half wax embedding and acid bathing. Characterisations were performed histologically for the presence/absence of cellular staining in both peripheral and central tissue areas (n=3 for each cortical/cancellous, test/PBS control and peripheral/central group), and with BioDent reference point indentation (RPI) for pre- and post-processing mechanical properties. Histology revealed absent cellular staining in peripheral and central cancellous samples, whilst reduced in cortical samples compared to controls. Cancellous samples decreased in wet mass after decellularisation by 45.3% (p<0.001). RPI measurements associated with toughness (total indentation depth, indentation depth increase) and elasticity (1st cycle unloading slope) showed no consistent changes after decellularisation. X-rays confirmed half wax embedding provided predictable control of the mineralised-demineralised interface position. Initial optimisation trials show proof-of-concept of a soft-hard hybrid scaffold as an immune compatible xenograft for irreparable rotator cuff tears. Decellularisation did not appreciably affect mechanical properties, and further biological, structural and chemical characterisations are underway to assess validity before in vivo animal trials and potential clinical translation