Advertisement for orthosearch.org.uk
Results 1 - 20 of 36
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 65 - 65
23 Jun 2023
Koller T Reisinger C Beck M
Full Access

To quantify the acetabular coverage of the femoral head, Lequesne's vertical-center-anterior edge (VCA) angle is used on the false profile view. Lateral coverage is determined by Wiberg's lateral-center-edge (LCE) angle on an ap pelvic view. The delimitation of the weightbearing area is defined by the end of the subchondral sclerosis line for both views. To our knowledge the exact anatomic location of the points used for measurement on the acetabular rim are not known. Six hips from three cadaver pelvises (3 male and 3 female) were investigated. The anterior and lateral points of interested were identified radiographically using fluoroscopy and marked with 1mm ceramic bullets. Standard false profile views and ap pelvic views in neutral inclination and rotation were taken to check the correct location of the ceramic bullets. A CT of each pelvis was made to locate the ceramic bullets and to define the exact anatomic location of the measurement points on the o'clock position. 6 o‘clock was defined as the midpoint between anteroinferior and the posteroinferior rim edges. Values were normalized for a right hip. The mean clockface location for the VCA was 1:33 (range, 1:15 to 1:40) and for the LCE 0:38 (range, 0:20 to 0:50). The LCEA is slightly anterior to the 12 o'clock position and remains useful to quantify the lateral coverage. Surprisingly, the point used for measuring the VCA is only about 30° (1h) anterior of the point used for measuring the LCEA. Its value for determining anterior cover has to be questioned. The discrepancy to other studies in the literature is because this study identifies and measures the end of the weight bearing zone, and not the border of the bony acetabulum


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 6 - 6
19 Aug 2024
Lausmann C Luck S Beil FT Citak M Gehrke T
Full Access

Mechanical failure due to dislocation, fracture and acetabular wear as well as persistence of infection are the main complications associated with the use of hip spacers in the treatment of periprosthetic joint infections (PJI). We have developed a novel, custom-made spacer as part of two-stage septic hip replacement and present the two- to five-year results after reimplantation. We prospectively examined a total of 73 patients over our study period in whom our new spacer technique was used. The technique includes a dual mobility inlay and a cemented straight stem in combination with antibiotic-loaded PMMA bone cement which allows full weight bearing meanwhile the interim period. The follow-up ranged between 24 and 60 months after reimplantation as second stage of a two-stage approach. The patients were contacted as part of the follow-up using a questionnaire concerning reoperation, reinfection as well as hip function by using the Harris Hip Score. 72 patients (98,6%) could be reimplanted, one patient is still using the spacer prothesis for 45 months because of excellent functional results with a Harris Hip Score of 95, nevertheless reimplantation is planned. The reinfection rate was less than 7% after reimplantation. The dislocation rate was 5%, and in total there was an overall complication rate of less than 10%. The Harris Hip Score was significantly improved. The ENDO spacer surgical technique is a promising option in the treatment of periprosthetic joint infections (PJI) for two-stage septic exchange with a low dislocation rate and good infection control after reimplantation. In addition, it enables early mobilization with the possibility of full weight-bearing in the interval between spacer implantation and reimplantation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 6 - 6
2 May 2024
Langdown A Goriainov V Watson R
Full Access

Gluteal Tendinopathy is a poorly understood condition that predominantly affects post-menopausal women. It causes lateral hip pain, worse when lying on the affected side or when walking up a hill or stairs. It has been labelled ˜Greater Trochanteric Pain Syndrome” a name that recognises the lack of understanding of the condition. Surgical reconstruction of the gluteal cuff is well established and has been undertaken numerous times over the last 16 years by the senior author (AJL). However, the quality of collagen in the tendons can be very poor and this leads to compromised results. We present the results of gluteal cuff reconstruction combined with augmentation using a bioinductive implant. 14 patients (11 female, 3 male; mean age 74.2 ± 6.3 years) with significant symptoms secondary to gluteal tendinopathy that had failed conservative treatment (ultrasound guided injection and structured physiotherapy) underwent surgical reconstruction by the senior author using an open approach. In all cases the iliotibial band was lengthened and the trochanteric bursa excised. The gluteal cuff was reattached using Healicoil anchors (3–5×4.75mm anchors; single anchors but double row repair) and then augmented using a Regeneten patch. Patients were mobilised fully weight bearing post-operatively but were asked to use crutches until they were no longer limping. All had structured post-surgery rehabilitation courtesy of trained physiotherapists. There were no post-operative complications and all patients reported an improvement in pain levels (Visual Analogue Scale 7.8 pre-op; 2.6 post-op) and functional levels (UCLA Activity Score 3.5 pre-op; 7.1 post-op) at 6 months post surgery. Surgery for gluteal tendinopathy produces good outcomes and the use of Regeneten as an augment for poor quality collagen is seemingly a safe, helpful addition. Further comparative studies would help clarify this


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 60 - 60
19 Aug 2024
Lau LCM Cheung MH Ng FY Fu H Chan PK Chiu P
Full Access

In total hip arthroplasty (THA), cementless cup without screw holes has the putative benefits of maximizing host bone contact and reducing osteolysis by eliminating channels to backside wear particles. However, supplemental trans-acetabular screws cannot be used. 74 hips in 60 patients receiving same model of cementless cup without screw holes (Depuy Duraloc 100 HA cup) from 6/1999 to 3/2003 were prospectively followed up. All patients were allowed to have immediate full weight bearing. Age at THA was 53 ± 13 (range 24–74) years. Osteonecrosis was the leading hip disease (45% of hips). Survivorship was assessed using revision of the cup as the end point. Radiological parameters, including lateral opening angle, vertical and horizontal migration distances of the cups were measured. Paired t-test was used to compare between the measurements in early postoperative period and at final follow up. 51 hips were assessed at minimum 20 years follow-up. The mean follow-up was 22.6 (range 21 – 25) years. All the cups were well fixed. There were two cup revisions. Conventional polyethylene (PE) was used in both hips; osteolysis occurred 17 and 18 years later. Both cups were well fixed but were revised, one due to cup mal-positioning, one due to need in upsizing the articulation. 14 other hips were revised but these cups were well fixed and not revised; 9 loosened stems (most were cemented Elite plus stems), 5 PE wear and osteolysis (all were conventional PE). At 20 years, the survivorship of cups was 96.1%. Changes in lateral opening angle, vertical and horizontal migration distances were 0.44±1.59°, 0.01±1.52mm and -0.32±1.47mm respectively, without statistical significance. This study provided evidence of excellent long-term survivorship of cementless cup without screw holes. Immediate postoperative weight-bearing also did not lead to cup migration in the long-term


Displaced acetabular fractures in the older patient present significant treatment challenges. There is evidence the morbidity and mortality associated is similar to the fractured neck of femur cohort. Despite growing literature, there remains significant controversy regarding treatment algorithms; varying between conservative management, to fracture fixation and finally surgical fixation and simultaneous THA to allow immediate full weight bearing. £250k NIHR, Research for Patient Benefit (Ref: PB-PG-0815-20054). Trial ethical approval (17/EE/0271). After national consultation, 3 arms included; conservative management, fracture fixation and simultaneous fracture fixation with THA. Statistical analysis required minimum 12 patients/3 arms to show feasibility, with an optimum 20/arm. Inclusion criteria; patients >60 years & displaced acetabular fracture. Exclusion criteria: open fracture, THA in situ, pre-injury immobility, polytrauma. Primary outcome measure - ability recruit & EQ-5D-5L at 6 months. Secondary outcome measures (9 months); OHS, Disability Rating Index, radiographs, perioperative physiological variables including surgery duration, blood loss, complications and health economics. 11 UK level 1 major trauma centres enrolled into the trial, commenced December 2017. Failure surgical equipoise was identified as an issue regarding recruitment. Full trial recruitment (60 patients) achieved; 333 patients screened. 66% male, median age 76 (range 63–93), median BMI 25 (range 18–37), 87% full mental capacity, 77% admitted from own home. 75% fall from standing height. 60% fractures; anterior column posterior hemi-transverse. Trial feasibility confirmed December 2020. Presented data- secondary outcomes that are statistically significant in improvement from baseline for only the fix and replace arm, with acceptable trial complications. Issues are highlighted with conservative management in this patient cohort. Our unique RCT informs design and sample size calculation for a future RCT. It represents the first opportunity to understand the intricacies of these treatment modalities. This RCT provides clinicians with information on how best to provide management for this medically complex patient cohort


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 8 - 8
1 Aug 2018
Timperley J
Full Access

The principle function of the “short external rotator” muscle group is primarily as an abductor and extensor of the flexed hip and is better referred to as the “Quadriceps Coxa” (QC). The QC has a profound influenced on weight bearing rising and propulsive motions. The SPAIRE technique preserves Obturator Internus (OI) and Piriformis (P) resulting in improved stability of the hip and potentially improved recovery and function in patients undergoing hip arthroplasty. Short term outcomes of the first 42 consecutive SPAIRE cases are compared with 86 consecutive cases using the traditional posterior approach that immediately preceded introduction of the technique. The purpose was to document the learning curve and confirm the safety of introducing SPAIRE into routine clinical practice. The two groups were comparable and there was no statistically significant difference in length of stay, blood loss, intra-or post-operative complications nor radiological measurements relating to the femoral or acetabular components. Statistically significant differences were found for component usage (more uncemented acetabula for SPAIRE), length of operation (8 mins longer with SPAIRE); patient satisfaction was higher at 6 weeks and measured leg length discrepancy less in the SPAIRE group. SPAIRE has been used routinely for all routine arthroplasties for over two years. RCTs are ongoing to document the effect of SPAIRE on recovery, long term function and activity level. If the potential benefits are confirmed SPAIRE may become the default technique for hip arthroplasty operations through a posterior approach for elective and hip fracture cases


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 42 - 42
1 May 2018
Chou D Abrahams J Callary S Costi K Howie D Solomon B
Full Access

Introduction. Severely comminuted, displaced acetabular fractures with articular impaction in the elderly population present significant treatment challenges. To allow early post-operative rehabilitation and limit the sequelae of immobility, treatment with acute total hip replacement (THA) has been advocated in selected patients. Achieving primary stability of the acetabular cup without early migration is challenging and there is no current consensus on the optimum method of acetabular reconstruction. We present clinical results and radiostereometric analysis of trabecular metal (TM) cup cage construct reconstruction in immediate THA without acetabular fracture fixation. Methods. Between 2011 and 2016, twenty-one acetabular fractures underwent acute THA with a TM cup cage construct. Patient, fracture and surgical demographics were collected. They were followed up for a mean of 24months (range 12–42months). Clinical and patient reported outcome measures were collected at regular post-operative intervals. Radiosterometric analysis (RSA) was used to measure superior migration and sagittal rotation of the acetabular component. Results. Thirteen fractures were classified as anterior column posterior hemi-transverse, two anterior column, two transverse and four associated both column acetabular fractures. There was one case of trochanteric fracture and transient foot drop. Mean Harris Hip Scores at 12months was 79 (range 33–98). The mean proximal migration of the acetabular components at 12months was 0.91mm (range 0.09–5.12 and mean sagittal rotation was 0.52mm (range 0.03–7.35). Conclusion. The TM cup-cage technique requires a single approach and provides immediate cup stability allowing full weight bearing day one post-op. To our knowledge this is the first study to accurately measure cup stability following THA for an acetabular fracture. Our promising early clinical and radiological outcomes suggest this technique may be an alternative to a fix and replace construct for immediate THA for acute acetabular fractures in the elderly


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 11 - 11
1 May 2018
Thurston D Marson B Jeffery H Ollivere B Westbrook T Moran C
Full Access

Background. Isolated fracture of the greater trochanter is an uncommon presentation of hip fracture. Traditional teaching has been to manage these injuries nonoperatively, but modern imaging techniques have made it possible to detect occult intertrochanteric extension of the fracture in up to 90% of cases. This study aims to review the investigation and management of greater trochanter fractures in a single major trauma centre. Methods. A retrospective review was completed of patients admitted with greater trochanter fractures. These were matched to cases with 2-part extracapsular fractures. Initial management and clinical outcome was established using electronic notes and radiographs. Mortality and length of stay was calculated for both groups. Results. 85 isolated greater trochanter fractures in 84 patients were identified from 2006–2017. 81/85 patients were treated non-operatively. 78 were mobilised full weight bearing. None required readmission or operation due to fracture displacement. 58 of these patients had cross-sectional imaging with MRI or CT and 15 of those scanned had intertrochanteric extension of the fracture. In the same time period, 998 2-part extra-capsular fractures were treated, using a sliding hip screw. Length of stay was shorter in patients with greater trochanter fractures than 2-part extracapsular fractures (median 7 days vs 14 days, P<0.0001). 30-day mortality was 11.9%, with no significant difference to patients with 2-part extracapsular fractures. Discussion. Cross sectional imaging rarely changed the treatment protocol for isolated greater trochanter fractures. The outcome following non-operative treatment is good even in the presence of occult fractures identified on CT or MRI. We advocate a treatment protocol that encourages early mobilisation and repeat plain radiographs if patients fail to progress. This will reduce unnecessary morbidity from fixation of stable occult fractures


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 41 - 41
1 Jan 2018
Timperley A Hanly R
Full Access

The SPAIRE technique (Spare Piriformis And Internus, Repair Externus) involves a muscle sparing mini-posterior approach to the hip. Evidence will be prevented that the principle function of the “short external rotator” muscle group is primarily as an abductor and extensor of the flexed hip and has a profound influenced on weight bearing rising and propulsive motions; also that details of the insertions of the piriformis tendon and conjoint insertion of obturator internus and the gemelli (the Quadriceps Coxa) have previously been poorly appreciated. We have developed a surgical technique (SPAIRE) during which the only tendon released, and subsequently repaired, is obturator externus. The author has carried out the SPAIRE technique for all routine hip arthroplasties for the last 18 months. This cohort has been compared with a matched control group for a comprehensive array of outcome measures. Results show no disadvantage of using the technique. On-table stability is so impressive that when the SPAIRE technique has been used no postoperative restrictions whatsoever are placed on the patient who is immediately encouraged to exercise the hip through a full excursion of movement. Fewer tendons are damaged using the SPAIRE technique than any other approach to the hip including Direct Anterior and Direct Superior approaches. Randomised prospective studies are on-going using objective measurements of Gait and muscle power as well as functional and patient reported outcomes to prove benefit of the SPAIRE technique. For hemiarthroplasty cases a separate RCT is being undertaken comparing the SPAIRE technique with a direct lateral approach. It is believed that this technique may become the default technique for hemi- and total- hip arthroplasty through a posterior approach and for all hip fracture arthroplasty cases


The Bone & Joint Journal
Vol. 98-B, Issue 1_Supple_A | Pages 64 - 67
1 Jan 2016
Lachiewicz PF Watters TS

The ‘jumbo’ acetabular component is now commonly used in acetabular revision surgery where there is extensive bone loss. It offers high surface contact, permits weight bearing over a large area of the pelvis, the need for bone grafting is reduced and it is usually possible to restore centre of rotation of the hip. Disadvantages of its use include a technique in which bone structure may not be restored, a risk of excessive posterior bone loss during reaming, an obligation to employ screw fixation, limited bone ingrowth with late failure and high hip centre, leading to increased risk of dislocation. Contraindications include unaddressed pelvic dissociation, inability to implant the component with a rim fit, and an inability to achieve screw fixation. Use in acetabulae with < 50% bone stock has also been questioned. Published results have been encouraging in the first decade, with late failures predominantly because of polyethylene wear and aseptic loosening. Dislocation is the most common complication of jumbo acetabular revisions, with an incidence of approximately 10%, and often mandates revision. Based on published results, a hemispherical component with an enhanced porous coating, highly cross-linked polyethylene, and a large femoral head appears to represent the optimum tribology for jumbo acetabular revisions. Cite this article: Bone Joint J 2016;98-B(1 Suppl A):64–7


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 33 - 33
1 Jun 2016
Bhaskar D Nagai H Kay P
Full Access

Introduction. Limb Length discrepancy after total hip replacement has been reported to happen in 1–27% of cases with differences up to 70mm. Occasionally revision THR has been used to achieve limb length equalisation, especially when patients are symptomatic with hip/back pain, neurologic symptoms or instability. However, in presence of a well-functioning, pain free hip without hip symptoms, revision THR for shortening can lead to problems with decrease in offset or stability. An option in these cases would be a distal shortening osteotomy of femur. Materials and Methods. From 2005 to 2014 five shortening osteotomies were done for LLD with limb lengthening of ipsilateral side following THR. All patients had well-functioning THRs with and no complications as dislocations or nerve symptoms. A distal metaphyseal shortening osteotomy, fixed using a 95 degree blade plate, was chosen for better healing at this level and ease of surgery. Results. Cause of LLD – Patient 1 had ‘neck preserving’ Hip replacement and post-operative lengthening. Patient 2 had Bilateral DDH with B/L THR, but with sub-trochanteric shortening on one side and not the other. Patient 3 had Bilateral DDH treated with THR with high hip centre on one side and at site of native cup on the other. Further two patients had total hip replacements for DDH. The average lengthening was 28mm (25 – 32mm). No patients had neuro-vascular compromise. All achieved radiological and clinical union by 3 months. At one year all patients were weight bearing without pain or discomfort and had full range of movement at knee. One patient required removal of plate due to discomfort that resolved following plate removal. Conclusion. Our series of patients demonstrate that in cases with symptomatic limb lengthening in presence of an otherwise well-functioning THR, shortening osteotomy of distal metaphysis of femur is a viable option


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 53 - 53
1 Nov 2015
Jones A Williams T Paringe V White S
Full Access

Introduction. The number of total hip replacements taking place across the UK continues to grow. In an ageing population, with people living longer and placing greater strain on their prostheses, the number of peri-prosthetic femoral fractures is increasing. We studied the economic impact this has on a large university teaching hospital. Method. All patients with a peri-prosthetic femoral fracture between 24/11/2006 and 31/5/2014 were identified using theatre databases. Radiographic and case note analysis was performed for each case. Costings from finance department for implants and in-patient stay were obtained. Results. 90 cases were identified, 58 female and 32 male, with a mean age of 76 (range: 38–91). 86 fractures occurred around total hip replacements, 4 around hemi-arthroplasties. 89 of the cases were managed surgically, 66% undergoing revision and 33% receiving open reduction and internal fixation (ORIF). According to the Vancouver Classification, 3% were Type A, 79% Type B and 18% Type C. The mean length of stay for all fractures was 43 days, ranging from 5 – 179. The mean overall cost of management was £31,370 (range: £6885 – £112,327). Patients with type C fractures had the highest mean length of stay at 53 days and highest overall mean cost of £33,417. Conclusion. When including rehabilitation costs, our study illustrated a mean cost of £31370, roughly four times the NHS tariff of £8552 and significantly greater than the £3702 per case recovered by one UK teaching hospital. This equates to an average £22000 shortfall per case for peri-prosthetic fractures alone at our institution. Although implant costs are greater, treatment with revision where appropriate allows earlier weight bearing, reduced length of stay and rehabilitation costs and lower overall cost


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 45 - 45
1 Nov 2015
Baker P
Full Access

Introduction. The Exeter RimFit™ flanged cemented cup features ultra-highly cross-linked polyethylene and was introduced onto the market in the UK in 2010. We aimed to examine the rates of radiolucent lines observed when the Rimfit™ cup was implanted using a ‘rimcutter’ technique with the cup sitting on a prepared acetabular rim, and a ‘trimmed flange’ technique were the flange is cut so that it sits inside the prepared acetabular rim. Patients/Materials & Methods. The radiographs of 150 (75 ‘rimcutter’, 75 ‘trimmed flange’) Rimfit™ hip replacements were critically evaluated to assess for radiolucency at the cement bone interface. This group was then compared to a historic pre-Rimfit™ cohort of 76 patients. Results. Rimfit™ Cups inserted using the rimcutter technique exhibited significantly higher rates of radiolucency than cups inserted using the trimmed flange technique at 1 year post surgery (1 Delee and Charnley zone: rimcutter=73/77 (95%) versus trimmed flange=14/75 (19%); 2 zones: 43/75 (57%) versus 0/75 (0%); all 3 zones: 13/75 (17%) versus 0/75 (0%):(p<0.01)). There were significantly more radiolucencies for the ‘rimcutter’/Rimfit™ group when compared to a historic group of non-‘rimcutter’/non-Rimfit™ cups implanted by the same surgeon (p<0.01). Discussion. 95% of Rimfit™ cups inserted using the rimcutter technique exhibited radiolucent lines at 12 months. This may be due to increased flange stiffness related to the ultra-highly cross-linked polyethylene and the closer seal due to the narrow circumferential ridge created by the rimcutter. Insertion of the cup may lead to lower initial cement penetration which further deteriorates with weight bearing due to the flange offloading the socket. This may be exacerbated by hydraulic pumping of fluid trapped under the flange at the time of implantation that further degrades the cement bone interface. Conclusion. On the basis of these results we have stopped using the Rimfit™ cup in combination with the rimcutter device and technique


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 665 - 671
1 Apr 2021
Osawa Y Seki T Okura T Takegami Y Ishiguro N Hasegawa Y

Aims

We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH).

Methods

This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to total hip arthroplasty (THA) and radiological failure as the endpoints.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 838 - 844
1 Jul 2020
Chen L Hong G Hong Z Lin T Chen Z Zhang Q He W

Aims

The aim of this study was to report the medium-term outcomes of impaction bone allograft and fibular grafting for osteonecrosis of the femoral head (ONFH) and to define the optimal indications.

Methods

A total of 67 patients (77 hips) with ONFH were enrolled in a single centre retrospective review. Success of the procedure was assessed using the Harris Hip Score (HHS) and rate of revision to total hip arthroplasty (THA). Risk factors were studied, including age, aetiology, duration of hip pain, as well as two classification systems (Association Research Circulation Osseous (ARCO) and Japanese Investigation Committee (JIC) systems).


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 113 - 120
1 Jan 2019
Scholes CJ Ebrahimi M Farah SB Field C Cordingley R Kerr D Kohan L

Aims

The aim of this study was to report the implant survival and patient-reported outcome measures (PROMs) in a consecutive series of patients aged less than 50 years at the time of arthroplasty using the Birmingham Hip Resurfacing system (BHR), with a minimum follow-up of ten years.

Patients and Methods

A total of 226 patients with osteoarthritis of the hip, who underwent BHR and presented to a single surgeon, were included in the study. Survival of the implant was confirmed by cross-checking with the Australian Orthopaedic Association National Joint Replacement Registry. Kaplan–Meier survival curves with 95% confidence intervals (CIs) were constructed. Pre- and postoperative PROMs were compared with t-tests, and postoperative scores were compared using anchor analysis with age and gender matched normative data.


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 96 - 103
1 Jan 2019
Colo E Leenders LAM Rijnen WHC Schreurs BW Hannink G

Aims

The aim of this study was to analyze the effect of a lateral rim mesh on the survival of primary total hip arthroplasty (THA) in young patients, aged 50 years or younger.

Patients and Methods

We compared a study group of 235 patients (257 hips) who received a primary THA with the use of impaction bone grafting (IBG) with an additional lateral rim mesh with a group of 306 patients (343 hips) who received IBG in the absence of a lateral rim mesh during the same period from 1988 to 2015. In the mesh group, there were 74 male and 183 female patients, with a mean age of 35 years (13 to 50). In the no-mesh group, there were 173 male and 170 female patients, with a mean age of 38 years (12.6 to 50). Cox regression analyses were performed to study the effect of a lateral rim mesh on acetabular component survival. Kaplan–Meier analyses with 95% confidence intervals (CIs) were performed to estimate the survival of the acetabular implant.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 92 - 94
1 Nov 2013
Gehrke T Gebauer M Kendoff D

Femoral revision after cemented total hip replacement (THR) might include technical difficulties, following essential cement removal, which might lead to further loss of bone and consequently inadequate fixation of the subsequent revision stem.

Femoral impaction allografting has been widely used in revision surgery for the acetabulum, and subsequently for the femur. In combination with a primary cemented stem, impaction grafting allows for femoral bone restoration through incorporation and remodelling of the impacted morsellized bone graft by the host skeleton. Cavitary bone defects affecting meta-physis and diaphysis leading to a wide femoral shaft, are ideal indications for this technique. Cancellous allograft bone chips of 1 mm to 2 mm size are used, and tapered into the canal with rods of increasing diameters. To impact the bone chips into the femoral canal a prosthesis dummy of the same dimensions of the definitive cemented stem is driven into the femur to ensure that the chips are very firmly impacted. Finally, a standard stem is cemented into the neo-medullary canal using bone cement.

To date several studies have shown favourable results with this technique, with some excellent long-term results reported in independent clinical centres worldwide.

Cite this article: Bone Joint J 2013;95-B, Supple A:92–4.


The Bone & Joint Journal
Vol. 96-B, Issue 11_Supple_A | Pages 27 - 31
1 Nov 2014
Kraay MJ Bigach SD

Degenerative problems of the hip in patients with childhood and adult onset neuromuscular disorders can be challenging to treat. Many orthopaedic surgeons are reluctant to recommend total hip replacement (THR) for patients with underlying neuromuscular disorders due to the perceived increased risks of dislocation, implant loosening, and lack of information about the functional outcomes and potential benefits of these procedures in these patients. Modular femoral components and alternative bearings which facilitate the use of large femoral heads, constrained acetabular components and perhaps more importantly, a better understanding about the complications and outcomes of THR in the patient with neuromuscular disorders, make this option viable. This paper will review the current literature and our experience with THR in the more frequently encountered neuromuscular disorders.

Cite this article: Bone Joint J 2014;96-B(11 Suppl A):27–31.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 109 - 113
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Pelvic discontinuity represents a rare but challenging problem for orthopaedic surgeons. It is most commonly encountered during revision total hip replacement, but can also result from an iatrogentic acetabular fracture during hip replacement. The general principles in management of pelvic discontinuity include restoration of the continuity between the ilium and the ischium, typically with some form of plating. Bone grafting is frequently required to restore pelvic bone stock. The acetabular component is then impacted, typically using an uncemented, trabecular metal component. Fixation with multiple supplemental screws is performed. For larger defects, a so-called ‘cup–cage’ reconstruction, or a custom triflange implant may be required. Pre-operative CT scanning can greatly assist in planning and evaluating the remaining bone stock available for bony ingrowth. Generally, good results have been reported for constructs that restore stability to the pelvis and allow some form of biologic ingrowth.

Cite this article: Bone Joint J 2013;95-B, Supple A:109–13.