INTRODUCTION.
Uncemented press-fit cups provide bone fixation in primary total hip replacement (THR). However, sometimes screws are needed to achieve primary stability of the socket. We analyzed biomechanical factors related to press-fit in seven cup designs and assessed whether screw use provides similar loosening rates to those of the press-fit technique. From a series of 1,350 primary uncemented THRs using seven different press-fit cup designs (a dome loading hemispheric cup and bi- or tri- radius cups), we only analyzed the 889 diagnosed of primary osteoarthritis. All cases were operated by the same surgical team. The use of screws was decided intraoperatively based on cup stability according to the pull-out test. There were 399 female and 490 male patients with a mean age of 65 years old. The mean follow-up was 8.6 years (5–13 years). The reconstruction of the hip rotation center was evaluated according to Ranawat.Introduction
Materials y Methods
Dislocation is one of the most important complications after primary total hip replacement (THR). The low incidence of this finding makes it difficult to analyse the possible risk factors. The surgical technique can also influence this rate through cup position or an adequate reconstruction of the hip. We assessed the demographic data and radiological reconstruction of the hip related to the appearance of dislocation after primary THR. 1414 uncemented THRs were recorded from our Local Joint Registry. The mean age of the patients was 60.1 years old (range, 14 to 95), and the mean weight was 73.3 kg (42 to 121). There were 733 men and 974 patients were classified with an activity level of 4 or 5 according to Devane. The most frequent diagnosis was primary osteoarthritis, 795 hips, followed by avascular necrosis 207 hips. An alumina-on-alumina THR was implanted in 703 hips and a metal-on-polyethylene THR in 711 hips. A femoral head size of 28 mm was used in 708 hips and 32 mm in 704. Radiological cup position was assessed using the acetabular abduction angle, the height of the center of the hip, and the horizontal distance of the cup. Cup anteversion was measured according to Widmer and the reconstruction of the center of rotation of the hip according to Ranawat. The radiographic reconstruction of the abductor mechanism was measured using two variables: the lever arm and the height of the greater trochanter.Introduction
Material and Methods
Hydroxyapatite (HA) coated femoral stems require a press fit for initial stability prior to osteointegration occurring. However this technique can lead to perioperative femoral fracture. 506 consecutive patients under 72 years who underwent primary total hip replacements (THR) under 72 years were investigated for perioperative femoral fractures. All patients were independently assessed pre- and post-operatively in a research clinic. Assessment was made by Merle d'Aubigné and Postel (MDP) hip scores and radiographs. Between 1995 and 2001 patients were randomised to a partially HA coated, Osteonics Omnifit or fully HA coated Joint Replacement Instrumentation Furlong stem. Between 2001 and 2004 all patients received an Anatomique Benoist Girard (ABG II) stem partially coated. Fractures were identified from check radiographs and operative notes. The type of fracture was classified according to the modified Vancouver classification. The incidence of revision was also recorded.Introduction
Materials and Methods
Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for revision surgery (8 hips for the whole series). The mean post-operative clinical score improved in all groups. The overall survival rate for revision for any cause at 120 months was 88.4% (95% CI 78.8–98), being 97.8% (95% CI 95.2–100) for group A, 81.8% (95% CI 64.8–98.8) for group B and 95.3% (95% CI 91.1–99.6) for group C (log Rank: 0.416). Five hips were revised for loosening. The overall survival rate for loosening at 120 months was 91.9% (95% CI 81.7–100), being 99.2%(95% CI 97.6–100) for group A, 85.5 (95% CI 69.9 −100) for group B and 100% for group C (Log Rank 0.093).Materials and Methods
Results
Objectives. To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing. Main outcome measures. Hip arthroplasty procedures were linked to the time to any subsequent mortality or revision (implant failure). Flexible parametric survival analysis methods were used to analyse time to mortality and also time to revision. Comparisons between procedure groups were adjusted for age, sex, American Society of Anesthesiologists (ASA) grade, and complexity. Results. Multivariable survival analyses identified a higher mortality rate for patients undergoing cemented compared with
Introduction. Dislocation of an
Introduction. Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue. Objetive. We assessed the clinical and radiological outcome of a single
Introduction. The use of screws is frequent for additional fixation, however, since some disadvantages have been reported a cup press-fit is desirable, although this can not always be obtained. Cup primary intraoperative fixation in
Introduction. Proper femoral reaming is a key factor for a successful outcome in cementless hip arthroplasty. Good quality reaming minimizes risks of intra-operative femoral fracture during reaming and prevents poor fitting of the implant which can lead to subsidance of the stem postoperativly. Determining the quality of reaming is largely a subjective skill and dependant on the surgeon's experience with no documented intraoprative method to assess it objectively. Method. We recorded and analysed the frequencies of sound signals recorded via a bone conduction microphone during reaming of the femoral canal in a series of 28 consecutive patients undergoing
Purpose. The purpose of this study was to determine the functional outcome, imaging and complications of conversion of hip fusion to
Pseudotumour formation is being reported with increasing frequency in failing metal-on-metal hip resurfacings and replacements. This mode of failure complication has also been reported with metal-on-polyethylene bearing bearings when it is usually associated with evidence of surface corrosion and no apparent wear at the head–neck taper. We present a case with evidence of taper wear and damage secondary to corrosion in an