Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

MORTALITY AND IMPLANT REVISION RATES FOLLOWING HIP RESURFACINGS AND HIP REPLACEMENTS

The International Society for Technology in Arthroplasty (ISTA), 28th Annual Congress. PART 1.



Abstract

Objectives

To examine mortality and revision rates among patients with osteoarthritis undergoing hip arthroplasty and to compare these rates between patients undergoing cemented or uncemented procedures and to compare outcomes between men undergoing stemmed total hip replacements and Birmingham hip resurfacing.

Main outcome measures

Hip arthroplasty procedures were linked to the time to any subsequent mortality or revision (implant failure). Flexible parametric survival analysis methods were used to analyse time to mortality and also time to revision. Comparisons between procedure groups were adjusted for age, sex, American Society of Anesthesiologists (ASA) grade, and complexity.

Results

Multivariable survival analyses identified a higher mortality rate for patients undergoing cemented compared with uncemented total hip replacement (adjusted hazard ratio 1.11, 95% confidence interval 1.07 to 1.16); conversely, there was a lower revision rate with cemented procedures (0.53, 0.50 to 0.57). These translate to small predicted differences in population averaged absolute survival probability at all time points. For example, compared with the uncemented group, at eight years after surgery the predicted probability of death in the cemented group was 0.013 higher (0.007 to 0.019) and the predicted probability of revision was 0.015 lower (0.012 to 0.017).

In multivariable analyses restricted to men, there was a higher mortality rate in the cemented group and the uncemented group compared with the Birmingham hip resurfacing group. In terms of revision, the Birmingham hip resurfacings had a similar revision rate to uncemented total hip replacements.

Discussion

There is a small but significant increased risk of revision with uncemented rather than cemented total hip replacement, and a small but significant increased risk of death with cemented procedures. It is not known whether these are causal relations or caused by residual confounding. Compared with uncemented and cemented total hip replacements, Birmingham hip resurfacing has a significantly lower risk of death in men of all ages. Previously, only adjusted analyses of hip implant revision rates have been used to recommend and justify use of cheaper cemented total hip implants. Our investigations additionally consider mortality rates and suggest a potentially higher mortality rate with cemented total hip replacements, which merits further investigation.

These results have now been confirmed by other Centres as well. [1,2] Our findings agree with those of Kendal et al who confirm that those undergoing metal-on-metal hip resurfacing have reduced mortality in the long term (up to 10 years) compared with those undergoing total hip replacement and that this difference persisted after extensive adjustment for confounding factors. Although residual confounding is possible, the observed effect size is large.


*Email: