Advertisement for orthosearch.org.uk
Results 1 - 20 of 71
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 1 - 1
1 Nov 2018
Ahmad A Mirza Y Teoh K Evans A
Full Access

Uncemented total hip arthroplasty (THA) implants have become the standard for younger patients on account of increased implant survivorship and multiple other advantages. Nevertheless, uncemented THA remains controversial in elderly patients. The evidence base for this is limited, as previous studies have compared octogenarians to a younger control group. The aim of this prospective cohort study is to evaluate the outcome of octogenarian patients undergoing uncemented THA with a control group of similarly aged patients undergoing hybrid THA with a minimum 5 years follow up. Clinical outcomes including intra and postoperative complications, blood transfusion, revision rate and mortality were recorded. Radiological analysis of pre and postoperative radiograph assessed bone quality, implant fixation and any subsequent loosening. 143 patients, (mean age 86.2 yrs.) were enrolled in the study. 76 patients underwent uncemented THA and 67 underwent hybrid THA. The uncemented cohort had fewer intraoperative and postoperative complications. The uncemented cohort also had a lower transfusion rate (p=0.002). Mean hospital stay (p=0.27) was comparable between the 2 groups. Two patients underwent revision surgery in either cohort. Our study demonstrates uncemented THA is safe for the octogenarian patient and we recommend that age should be not be a barrier of choice of implant. However intraoperative assessment of bone quality should guide surgeon to the optimum decision regarding uncemented and hybrid implant


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 80 - 80
17 Apr 2023
Azizova L Morgan D Rowlands J Brousseau E Kulik T Palianytsia B Mansell J Birchall J Wilkinson T Sloan A Ayre W
Full Access

Preventing infections in joint replacements is a major ongoing challenge, with limited effective clinical technologies currently available for uncemented knee and hip prostheses. This research aims to develop a coating for titanium implants, consisting of a supported lipid bilayer (SLB) encapsulating an antimicrobial agent. The SLB will be robustly tethered to the titanium using self-assembled monolayers (SAMs) of octadecylphosphonic acid (ODPA). The chosen antimicrobial is Novobiocin, a coumarin-derived antibiotic known to be effective against resistant strains of Staphylococcus aureus. ODPA SAMs were deposited on TiO. 2. -coated quartz crystal microbalance (QCM) sensors using two environmentally friendly non-polar solvents (anisole and cyclopentyl methyl ether, CPME), two concentrations of ODPA (0.5mM and 1mM) and two processing temperatures (21°C and 60°C). QCM, water contact angle measurements, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM) and temperature-programmed desorption mass spectrometry (TPD-MS) were used to characterise the ODPA SAM. A SLB with encapsulated Novobiocin was subsequently developed on the surface of the ODPA SAM using fluorescent lipids and a solvent assisted method. The prototype implant surface was tested for antimicrobial activity against S. aureus. A well-ordered, uniform ODPA SAM was rapidly formed using 0.5 mM ODPA in CPME at 21°C during 10 min, as confirmed by high Sauerbrey mass (≍285-290 ng/cm. 2. ), high atomic percentage phosphorus (detected using XPS) and high water contact angles (117.6±2.5°). QCM measurements combined with fluorescence microscopy provided evidence of complete planar lipid bilayer formation on the titanium surface using a solvent assisted method. Incorporation of Novobiocin into the SLB resulted in reduced attachment and viability of S. aureus. Key parameters were established for the rapid, robust and uniform formation of an ODPA SAM on titanium (solvent, temperature and concentration). This allowed the successful formation of an antimicrobial SLB, which demonstrated potential for reducing attachment and viability of pathogens associated with joint replacement infections


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 78 - 78
1 Apr 2017
García-Rey E García-Cimbrelo E Gómez-Barrena E
Full Access

Background and aim. Recent proposals have been introduced to modify stem design and/or femoral fixation in total hip replacement (THR). New designs need to consider previous design features and their results. The aim of this study has been to evaluate the clinical and radiological results of six different designs of tapered uncemented stems implanted in our Institution. Methods. 1918 uncemented hips were prospectively assessed from 1999 to 2011 (minimum follow-up of five years for the unrevised hips). All hips had a 28 or 32 mm femoral head and metal-on-polyethylene or alumina-on-alumina bearing surface. Six uncemented femoral designs that shared a femoral tapered stem incorporating a coating surface were included in the study. The different design features included the type of coating, metaphyseal filling, and sectional shape. Results. Intra-operative proximal femoral crack was 6.7% in one of the designs (p=0.01), univariate analysis showing a lower risk of crack in the other designs. The position of the stem was neutral in 80% of the cases for all designs. Femoral canal filing was related to the stem design (p<0.001 at the three levels) and to the femoral level assessed (subset alpha=0.005). Twelve stems were revised for aseptic loosening (6 from two different designs). The survival rate for femoral aseptic loosening at 15 years was 96.6% (95% CI 93.8 to 99.4) for one of these two designs ad 97.4% (95% CI95.5 to 99.6) for the other. Regression analysis showed that stem design was the only factor related to aseptic loosening when adjusted for femoral canal filling (at the three levels) stem position (neutral or not) and femoral type (cylindrical or not). Conclusion. Tapered uncemented stems consistently provide excellent bone fixation. New designs need to avoid changing successful features and concentrate on the less successful aspects


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 63 - 63
1 Jan 2017
Prakash R Malik S Hussain S Budair B Ranjitkar S Prakash D
Full Access

During revision THR, the surgery is often difficult and compromised due to lack of patient's bone especially in the pelvis. Any extra bone in the acetabulum is expected to be of advantage to the patient and the surgeon. The aim of this study was to see if preservation of medial acetabular osteophyte in uncemented total hip replacement had any adverse effect on the prosthesis survival or patient satisfaction. Conventional acetabular preparation involves reaming down to the true floor. This not only medialises the centre of rotation of the hip but also reduces the acetabular offset. In contrast the main surgeon preserved the acetabular offset by preserving some osteophytic bone between the true floor of the acetabulum and the acetabular cup. This is achieved by reaming the acetabular cavity conservatively while achieving secure primary fixation of the prosthesis. We report the outcome of a single surgeon series of such cases. The endpoint was assessed as the need for revision of the acetabular cup. A total of 106 consecutive patients were identified who underwent uncemented THR from 2005 to 2010. The medial osteophyte was measured on immediate post-operative x-rays, from the “teardrop” to the nearest point of the acetabular cup, by 3 surgeons (one consultant and 2 registrars). The patients were contacted for a telephone interview and their clinical notes, including x-rays, were reviewed. Outcome was available for 79 patients. 74 patients were available for follow-up and 5 patients died unrelated to THR. Average follow-up was for 8.3 years (range 5.5–10.8). Average age was 62 years. The average medial osteophyte was 1.98 mm (range 0–14mm). One patient had late infection and one had dislocation. There was not a single failure of the acetabular component. The patient satisfaction was high at 8.8 out of 10. Preservation of medial osteophyte in the acetabulum whilst doing uncemented THR has the advantage of retaining the patient's own bone stock which can be of great advantage to the surgeon as well as the patient should revision THR be required in future. Our study has shown that this can be achieved without compromising the survival of the prosthesis or the patient satisfaction. This technique may increase the range of motion of the hip by reducing the risk of bony or soft tissue impingement, and also reduce the risk of dislocation. Furthermore, not recreating the native centre of rotation of the hip does not seem to have any adverse effect for the patients, who are very happy with the outcome. We recommend that whilst doing uncemented THR, the acetabulum should not be reamed to the true floor as has been the conventional teaching, but attempt should be made to preserve some medial osteophyte where possible, at the same ensuring that good primary fixation of the cup is achieved. This is to give the patient and surgeon the advantage of extra available bone should revision surgery be required in the future


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 75 - 75
1 Jan 2017
Anand A Li L Trigkilidas D Patel A
Full Access

We performed a systematic review to compare outcomes of cemented versus uncemented trapezio-metacarpal joint (TMCJ) replacement for treatment of base-of-thumb arthritis. We assessed improvements in pain and function, range of movement (ROM), strength, complications and need for revision surgery. A thorough literature search was performed. A total of 481 studies were identified from the literature search (179 Medline, 253 Embase, 27 CINAHL, 22 Cochrane). Of 43 relevant titles 28 were selected for full-text review after assessment of the abstracts. Duplicate studies were removed. 18 studies met inclusion criteria on full-text review. All studies were of level IV evidence. There were no randomised controlled trials or meta-analyses. The studies were critically appraised using a validated scoring system. Most studies reported good outcomes for pain and strength, and functional outcome was comparable for both groups. ROM was generally improved for both prosthetic types, however statistical calculation was lacking in many studies. Trapezial component loosening was the main problem for both cemented and uncemented prostheses, however radiological loosening did not necessarily correlate with implant failure. This systematic review has found that both cemented and uncemented replacements generally give good outcomes for the treatment of TMCJ arthritis, however young, male, patients with manual occupations and with disease in the dominant hand and patients with poor trapezial bone stock appear to be at higher risk for implant failure due to cup loosening. We recommend the construction of a joint registry to record implantation and revision rates


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 74 - 74
1 May 2017
ten Broeke R Rudolfina R Geurts J Arts J
Full Access

Background. Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. Methods. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score. Results. In 2011 131 patients; 54 male and 76 female with average age of 60.83 (SD 12.42) and 60.57 (SD 12.11) year respectively underwent primary THA at our institution and all where included in our study cohort. Majority of this cohort underwent primary THA due to osteoarthrosis and most patients were classified ASO I (18%) or ASA II (65%). At two year clinical follow-up two revision were performed. One constituted a femur and acetabulum revision due to leg length difference and a snapping hip phenomenon. Complications included 3 dislocations (all treated policlinic), 4 deep infections (all treated with Genta PMMA beads with prosthesis in situ and healed) and 1 removal of hematoma. In another patient the femoral component was revised due to a peri-prosthetic fracture. Mean bone contact % values for all Charnley and DeLee zones combined were calculated and improved from 68,18% (SD 22,36) at 6 weeks to 73,61% SD (16,26) at 3 months to 84,21% (SD 19,02) at 6 months to 86,90% (SD 16,0) at 1 year to 92,19% (SD 12,74) at two year follow-up. When analysing the bone contact % per individual zone a remarkable difference was found for zones 2A-B. In contrast to zone 1A-B and 3A-B the initial bone contact % was clearly although not significantly lower until two year follow-up. Conclusions. In this study, the bone apposition around Tritanium actebular component was retrospectively assessed until two year clinical. Our results show excellent bone apposition that continues to improve over time (at least until two year clinical follow-up) suggesting that the open trabecular Ti structure of the Tritanium has a positive effect on cup osseointegration. However, some recent reports have shown the development of reactive lines around cups with porous/trabecular metal surfaces, of which the meaning is still unclear. Our analysis indicated that especially acetabular zone 2A-B according to Charnley&DeLee needs time to establish a direct contact of the implant surface and the surrounding bone tissues. Perhaps this might be explained by reaming technique (underreaming vs line to line reaming) resulting in suboptimal seating of the cup. Therefore, careful follow-up of this new implant technology will remain necessary and continued in this study. We aim to improve cohort size and establish results at longer follow-up times. Furthermore we aim to correlate these results to RSA component migration analysis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 55 - 55
1 Jan 2017
García-Rey E Gómez-Barrena E
Full Access

Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for revision surgery (8 hips for the whole series). The mean post-operative clinical score improved in all groups. The overall survival rate for revision for any cause at 120 months was 88.4% (95% CI 78.8–98), being 97.8% (95% CI 95.2–100) for group A, 81.8% (95% CI 64.8–98.8) for group B and 95.3% (95% CI 91.1–99.6) for group C (log Rank: 0.416). Five hips were revised for loosening. The overall survival rate for loosening at 120 months was 91.9% (95% CI 81.7–100), being 99.2%(95% CI 97.6–100) for group A, 85.5 (95% CI 69.9 −100) for group B and 100% for group C (Log Rank 0.093). Despite a more osteopenic bone in the cemented group, the rate of peri-prosthetic fractures was higher after uncemented THR in patients older than 75 years. Although the overall outcome is good with both types of fixation, the post-operative reconstruction of the hip, which might be more reliable after cemented fixation, may affect the rate of complications in this population


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 155 - 155
1 Jul 2014
Hutchinson R Choudry Q McLauchlan G
Full Access

Summary. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component has performed well at minimum of 5 years’ follow-up. Introduction. Total Knee Arthroplasty prostheses most frequently used in today's practice have cemented components. These have shown excellent clinical results. The fixation can however weaken with time, and cement debris within the articulation can lead to accelerated wear. Cementless implants are less commonly used, but some have also shown good long-term clinical results. The potential advantages of cementless implants are retention of bone stock, less chance of third-body wear due to the absence of cement, shorter operative time, and easier treatment of periprosthetic fractures. The posterior stabilised knee replacement has been said to increase tangential shear stresses on the tibial component and increases contact stresses on the cam and post mechanism hence the great debate of cruciate retaining or cruciate sacrificing implants. Objectives. We report the results of a prospective cohort of consecutive primary total knee arthroplasties using an uncemented posterior stabilised prosthesis using a trabecular metal (tantalum) tibial component at a minimum 5-year follow-up. Methods. Prospective 5 year follow-up of patients undergone an uncemented posterior stabilised total knee replacement using a trabecular metal tibial component (NexgenLPS). Clinical examination, Oxford knee score, Knee society score, SF12 and radiological evaluation undertaken at review. Results. 81 patients, 45 female, 36 male. Left 31, Right 50. Mean age 74.3 yrs range (51–90). SF12, mean: 31.8 range (25–37). Oxford Knee Score Pre-op Mean 20.1 range (9–36) Post op: Mean 32.1 range (9–48). Knee Society score. Pain Mean 91.8; range (60–100). Functional score mean 76.2; range (30–100). Mean Range of movement 110.5 degrees range (90–125). No evidence of loosening at 5 yrs. No deep infection. No Revisions. Conclusion. Although there are a variety of methods of achieving satisfactory initial fixation in cementless components, trabecular metal has an advantage owing to its cellular structure resembling bone. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component used in this series has shown no evidence of loosening at a minimum of 5 years’ follow-up and the prosthesis as a whole has performed very well clinically. Its early results are comparable to those prostheses most commonly used as reported by the arthroplasty registers. The longer term results from this prosthesis are awaited with interest


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 38 - 38
1 Aug 2013
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established, and a case note review was carried out. There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 15 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. There were no peri-prosthetic fractures in the cemented group, p = 0.004 using Fisher's exact test. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of the patients had a completed falls assessment and 21% sustained their fracture during an admission to hospital) and confusion (50% had a degree of dementia that caused significant confusion). Cemented implants should be considered in all patients, especially those who are cognitively impaired or have failed falls assessments; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 41 - 41
1 Jul 2014
Grosse S Høl P Lilleng P Haugland H Hallan G
Full Access

Summary. Particulate wear debris with different chemical composition induced similar periprosthetic tissue reactions in patients with loosened uncemented and cemented titanium hip implants, which suggests that osteolysis can develop independent of particle composition. Introduction. Periprosthetic osteolysis is a serious long-term complication in total hip replacements (THR). Wear debris-induced inflammation is thought to be the main cause for periprosthetic bone loss and implant loosening. The aim of the present study was to compare the tissue reactions and wear debris characteristics in periprosthetic tissues from patients with failed uncemented (UC) and cemented (C) titanium alloy hip prostheses. We hypothesised that implant wear products around two different hip designs induced periprosthetic inflammation leading to osteolysis. Patients & Methods. Thirty THR-patients undergoing revision surgery were included: Fifteen patients had loose cemented titanium stems (Titan. ®. , DePuy) and 15 had well-fixed uncemented titanium stems (Profile, DePuy), but loose or worn uncemented metal-backed cups with conventional UHMWPE liners (Gemini, Tropic and Tri-Lock Plus, DePuy; Harris/Galante and Trilogy, Zimmer). A semi-quantitative histological evaluation was performed in 59 sections of periprosthetic tissues using light microscopy. Wear particles were counted by polarised light and high resolution dark-field microscopy. Additionally, particle composition was determined by SEM-EDXA following particle isolation using an enzymatic digestion method. Blood metal ions were determined with high resolution-ICP-MS. Results. The implants in the uncemented group were revised after a median of 15.7 years (range: 7.25–19.3) due to osteolysis and high wear of the polyethylene liner and metal backing resulting in gross metallosis, and/or cup loosening. The average lifetime of implants in the cemented group was only 6.5 years (range: 1.5–11.75) due to early stem loosening with large osteolysis pockets in the femur close to the cement mantle. Tissue examination revealed similar results for both groups: numerous mononuclear histiocytes and chronic inflammatory cells, a few neutrophils and multinucleated giant cells, and to some extent necrosis. The amount of metal particles per histiocyte positively correlated with the tissue reactions in the cemented, but not in the uncemented group. A higher particle load (medians: C: 14727 vs. UC: 1382 particles/mm. 2. , p<0.0001) was found in tissues adjacent to cemented stems, which contained mainly submicron ZrO. 2. particles. Particles containing pure Ti or Ti alloy elements (size range: 0.21 to 6.46 µm) were most abundant in tissues from the uncemented group. Here, also PE was more frequent, but accounted only for a small portion of total particles (2.8 PE/mm. 2. ). The blood concentrations of titanium (range: 3.8–138.5 microgram/L) and zirconium (cemented cases, range: 0.6–3.5 microgram/L) were highly elevated in cases with high abrasive wear and metallosis. Discussion/Conclusion. Phagocytosis of different wear particles by histiocytes induced a similar chronic inflammatory reaction in the periprosthetic tissues in both groups. ZrO. 2. particles, originating from bone cement degradation, dominated in the cemented group, while in the uncemented group the high abundance of pure Ti and Ti alloy particles of various sizes indicates wear of the metal-backed cups. The low density of polyethylene particles in the tissues suggests that they are not solely responsible for the tissue reactions and accompanying osteolysis. Our findings suggest that the chemical composition of wear particles plays a minor role in the mechanism of osteolysis. Particle size, load and ionic exposure might be more important


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 41 - 41
1 Jun 2012
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established and a case note review carried out. There were 397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 14 patients (4% of uncemented arthoplasties) had peri-prosthetic fractures. The case notes of these patients were analysed. There was a common link of significant cardiovascular risk, lack of falls assessment, and confusion. Cemented implants should be considered in those who have failed falls assessment, or are confused; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaethetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 7 - 7
1 Aug 2013
Abram S Nicol F Hullin M Spencer S
Full Access

The long-term clinical and radiological results of 63 uncemented Low Contact Stress (LCS) total knee replacements in 47 patients with rheumatoid arthritis were reviewed. The average age at the time of surgery was 69 years (53–81). At a mean follow up of 22 years (20–25), 12 patients (17 knees) were alive, 27 (36 knees) had died, and 8 patients (10 knees) were lost to follow-up. Revision was necessary in seven patients (7 knees) (11.1%) at mean 12.1 years following surgery. Four revisions were performed due to meniscal bearing wear, two for collapse of the tibial component, and one for aseptic loosening. Evidence of post-operative infection occurred in two knees (3.2%) within 6 weeks of surgery but resolved with antibiotics. Within the group of deceased patients, five had undergone revision (included in total revisions) but otherwise the primary implant remained in vivo. For all living patients, the mean Oxford Knee Score (/48) was 30.2 (16–41) at latest follow up at mean 19.5 years (15–24.7) following surgery. Mean active flexion was 105 degrees (90–150) at this time point. Our recorded survival rate of the uncemented LCS total knee replacements in patients with rheumatoid arthritis was therefore 88.9% at mean 22 years, or worst-case survival of 73.0% if patients lost to follow-up were considered failures. From a review of the literature and as far as we are aware, this study represents the longest follow up of any uncemented knee arthroplasty performed in a cohort of patients with rheumatoid arthritis


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 77 - 77
1 May 2017
García-Rey E Gómez-Barrena E García-Cimbrelo E
Full Access

Background. Although the tribological characteristics are excellent, cup fixation has been one of the limitations in alumina-on-alumina total hip replacement (THR), so different types of materials and surfaces have been developing. We analysed the clinical and radiological outcome of two different uncemented cups for the same alumina-on-alumina THR. Methods. 679 hips were prospectively followed for at least 5 years. 342 had a hydroxyapatite (HA)-coated relatively smoothed tri-radius cup, implanted between 1999 and 2005 (group 1), and, 337 had a HA-coated macotextured tri-radius implanted between 2006 and 2009 (group 2). Dysplastic hips were more frequently observed in group 2. We compared screw use in both groups as primary fixation, the clinical results, and the radiological appearance of cup loosening. Results. Multivariate analysis showed that group 1, osteopenic and dysplastic acetabulae and women had a higher risk of screw use (p=0.004, HR: 1.68,95% CI: 1.18 to 2.41; p<0.001, HR: 2.25 95%, CI: 1.55 to 3.38; p<0.001, HR: 4.95, 95% CI: 2.83 to 8.64; p=0.011, HR: 1.58, 95% CI: 1.11 to 2.25, respectively). Although the pre-operative clinical score was worse in group 2, the post-operative results were better (p<0.001). There were no complications related to alumina. 15 cups were revised for loosening in the group 1 and 2 in the group 2. The cumulative probability of not having a revision for cup loosening at 15 years for the whole series was 93.3 % (95% CI: 89.6 to 96.9). The probability of not having cup loosening was 93.3% (95% CI: 89.7 to 96.9) in group 1 and 97.5% (95% CI: 93.5 to 100) in group 2. Conclusions. Despite worse pre-operative conditions, the macrotextured surface of the cup in the second group improved bone fixation in this series. Continued follow-up will be required to determine if reduction in wear between the alumina-on alumina bearings results in less osteolysis and loosening


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 60 - 60
1 Jan 2017
Li L Logan K Nathan S
Full Access

Contrary to NICE guidance there remains a role for Austin-Moore hemiarthroplasty (AM) for patients with significant pre-existing comorbidities who are at higher risk of death and complications following cemented hemiarthroplasty. We analysed prospectively-collected data comparing uncemented AM hemiarthroplasty in frail, poorly-mobile patients, and cemented hemiarthroplasty. We analysed age, pre-operative morbidity, duration of operation, death rate and complication rate. AM patients were significantly older with significantly higher ASA grades. It took significantly longer to optimise them before surgery. AM was significantly shorter to perform. There was no significant difference in complications requiring re-operation. Twice as many AM patients developed post-operative pneumonia despite absence of cement. Twice as many AM patients died after surgery and a significant proportion died within the first month despite no increased risk of repeat operation, shorter operating time and no risk of cement-disease. We infer that these patients would likely have fared badly had they undergone a longer, cemented procedure. A modern cemented prosthesis costs £691 more than AM. There exists a subset of patients within the neck of femur cohort who are significantly more unwell. Contrary to guidelines, we suggest that the cheaper, user-friendly Austin-Moore can be a reasonable prosthesis to use for this cohort


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 142 - 142
1 Jul 2014
Mohaddes M Malchau H Herberts P Johansson P Kärrholm J
Full Access

Summary Statement. We analysed impaction bone grafting used together with cemented or uncemented fixation in acetabular revision surgery. The overall risk for re-revision did not differ between the cemented and uncemented group. However, aseptic loosening was more common in the cemented group. Background. Several surgical techniques address bone defects in cup revision surgery. Bone impaction grafting, introduced more than thirty years ago, is a biologically and mechanically appealing method. The primary aim of this study was to evaluate the effect of bone impaction grafting when used with uncemented and cemented fixation in cup revision surgery. Uncemented cups resting on more than 50% host bone were used as controls. Patient and Methods. Cup fixation was studied in ninety hips (eighty-two patients), revised due to loosening between 1993 and 1997. There were fifty-three isolated cup and thirty-seven total revisions. Patients were followed for thirteen years using conventional radiography, radiostereometry (RSA), Harris Hip score and a pain questionnaire. Peroperatively the surgeon assessed the acetabular bone bed vitality. In hips where the cup was judged to rest on > 50% vital bone (group I, n=43), an uncemented cup was used. If the cup was resting on ≤ 50% living bone, uncemented (group IIa, n=21,) or cemented (group IIb, n=26) technique was chosen, according to the surgeon's preference. The mean age of patients at index revision was 61±12 years, 56% were females. The most common index diagnosis was primary osteoarthritis (n=45) followed by rheumatoid arthritis (n=10). Results. At thirteen years, acetabular component failure had necessitated a second revision in 6/7/8 hips in Groups I/IIa/IIb respectively. These re-revisions were performed 1–10 (mean 7.1) years after index revision. Moreover four cup / liner revisions were performed in hips with femoral loosening, not allowing further RSA measurements. These twenty-five hips were followed until re-revision. Deceased patients (n=21) and patients with deteriorating medical condition, not able to attend the follow-up (n=7), were censored in the survival statistics. Aseptic loosening was the most common reason of re-revision. However, in the uncemented groups (I/IIa), four cups were re-revised due to liner wear, osteolysis or instability. In the total study population, and up to two years, the median proximal migration was lowest in Group I followed by Group IIa and Group IIb (p≤0,006). At thirteen years the mean proximal migration was highest in Group IIb 1.29 mm (SD 1.23) followed by Group I 0.30 mm (SD 0.40) and Group IIa 0.22 mm (SD 0.22), p = 0.05. In cases subsequently re-revised because of loosening or with radiographically loose cups at the last follow-up, a higher proximal migration was observed compared to the non-revised and radiographically well-fixed group (up to seven years: p < 0.001; thirteen years: p=0.04). Discussion/Conclusion. We found an increased risk for rerevision in cases with less than 50% host bone-implant contact. These cups showed high early proximal migration, measured by RSA, indicating poor initial fixation. Rate of re-revision due to any reason did not differ between cemented and uncemented cups. The cemented group (IIb) had a higher risk of being re-revised due to aseptic loosening. Poor bone stock, use of small bone chips, inferior impaction technique, and no or restricted contact with living bone are probable reasons for failures when extensive bone grafting is needed


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 345 - 350
1 Mar 1998
Önsten I Carlsson ÅS Besjakov J

We used radiostereometric analysis to compare wear rates between uncemented porous sockets and cemented all-polyethylene sockets in a series of 102 hips randomised for either a Harris-Galante or a Charnley cup. Wear was evaluated in 95 hips at a mean of five years (2 to 7). All hips had a cemented, 22 mm head mono-bloc Charnley stem. The mean annual wear rate was 0.09 mm in the Charnley sockets and 0.10 mm in the Harris-Galante sockets, with no statistically significant differences in wear, migration or rotation. We conclude that, up to five years, the wear characteristics of the modular and porous Harris-Galante socket resemble that of the Charnley socket


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 1 | Pages 18 - 21
1 Jan 1996
Kreibich DN Moran CG Delves HT Owen TD Pinder IM

We measured the levels of cobalt and chromium in the serum in three groups of patients after uncemented porous-coated arthroplasty. Group 1 consisted of 14 consecutive patients undergoing revision for aseptic loosening. Group 2 comprised 14 matched patients in whom the arthroplasty was stable and group 3 was 14 similarly matched patients with arthritis awaiting hip replacement. Specimens were analysed using atomic absorption spectrophotometry. Aseptic loosening of a component resulted in a significant elevation of serum cobalt (p < 0.05), but not of serum chromium. The relative risk of a component being loose, if the patient had a serum cobalt greater than 9.0 nmol/l, was 2.8


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 6 | Pages 921 - 929
1 Aug 2001
Aamodt A Lund-Larsen J Eine J Andersen E Benum P Husby OS

We have compared the changes in the pattern of the principal strains in the proximal femur after insertion of eight uncemented anatomical stems and eight customised stems in human cadaver femora. During testing we aimed to reproduce the physiological loads on the proximal femur and to simulate single-leg stance and stair-climbing. The strains in the intact femora were measured and there were no significant differences in principal tensile and compressive strains in the left and right femora of each pair. The two types of femoral stem were then inserted randomly into the left or right femora and the cortical strains were again measured. Both induced significant stress shielding in the proximal part of the metaphysis, but the deviation from the physiological strains was most pronounced after insertion of the anatomical stems. The principal compressive strain at the calcar was reduced by 90% for the anatomical stems and 67% for the customised stems. Medially, at the level of the lesser trochanter, the corresponding figures were 59% and 21%. The anatomical stems induced more stress concentration on the anterior aspect of the femur than did the customised stems. They also increased the hoop strains in the proximomedial femur. Our study shows a consistently more physiological pattern of strain in the proximal femur after insertion of customised stems compared with standard, anatomical stems


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 39 - 39
1 May 2017
Gee C Poole W Wilson D Gibbs J Stott P
Full Access

Adverse reaction to metal debris (ARMD) is well recognised as a complication of large head metal on metal total hip replacement (THR) leading to pain, bone and tissue loss and the need for revision surgery. An emerging problem of trunnionosis in metal on polyethylene total hip replacements leading to ARMD has been reported in a few cases. Increased metal ion levels have been reported in THR's with a titanium stem and a cobalt chrome head such as the Accolade-Trident THR (Stryker).

We present 3 cases of ARMD with Accloade-Trident THR's with 36mm cobalt chrome head and a polyethylene liner. Metal ion levels were elevated in all three patients (cobalt 10.3 – 161nmol/l). Intraoperative tissue samples were negative for infection and inflammatory markers were normal. Abnormal fluid collections were seen in all three cases and bone loss was severe in one patient leading to a proximal femoral replacement. Histology demonstrated either a non-specific inflammatory reaction in a case which presented early or a granulomatous reaction in a more advanced case suggesting a local foreign body reaction. All patients had improved symptoms post-operatively. 1 patient who had staged bilateral Accolade-Trident THR's required revision of both THR's.

ARMD in metal on polyethylene THR's with a titanium stem represents a potential emerging problem. Further studies are required to assess whether these occurrences are rare or represent the tip of an iceberg.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 35 - 35
1 Dec 2021
Wang K Kenanidis E Miodownik M Tsiridis E Moazen M
Full Access

Abstract. Objectives. Stem malalignment in total hip arthroplasty (THA) has been associated with poor long-term outcomes and increased complications (e.g. periprosthetic femoral fractures). Our understanding of the biomechanical impact of stem alignment in cemented and uncemented THA is still limited. This study aimed to investigate the effect of stem fixation method, stem positioning, and compromised bone stock in THA. Methods. Validated FE models of cemented (C-stem – stainless steel) and uncemented (Corail – titanium) THA were developed to match corresponding experimental model datasets; concordance correlation agreement of 0.78 & 0.88 for cemented & uncemented respectively. Comparison of the aforementioned stems was carried out reflecting decisions made in the current clinical practice. FE models of the implant positioned in varus, valgus, and neutral alignment were then developed and altered to represent five different bone defects according to the Paprosky classification (Type I – Type IIIb). Strain was measured on the femur at 0mm (B1), 40mm (B2), and 80mm (B3) from the lesser trochanter. Results. Cemented constructs had lower strain on the implant neck, and higher overall stiffness and strain on bone compared to uncemented THA. Strain on the bone increased further down the shaft of the femoral diaphysis, and with progressing bone defect severity in all stem alignment cases. Highest strain on the femur was found at B2 in all stem alignment and bone defect models. Varus alignment showed higher overall femoral strain in both fixation methods. Interestingly, in uncemented models, highest strain was shown on femoral bone proximally (B1-B2) in varus alignment, but distally (B3) in neutral alignment. Conclusion. Varus stem alignment showed overall higher strain on femur compared to neutral and valgus. This highlights the crucial role of stem alignment in long term outcomes of THA. Differences between the two stem types should be taken in consideration when interpreting results from this study