Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff
Tendons display poor intrinsic healing properties and are difficult to treat[1]. Prior in vitro studies[2] have shown that, by targeting the Activin A receptor with magnetic nanoparticles (MNPs), it is possible to remotely induce the tenogenic differentiation of human adipose stem cells (hASCs). In this study, we investigated the tenogenic regenerative potential of remotely-activated MNPs-labelled hASCs in an in vivo rat model. We consider the potential for magnetic controlled nanoparticle mediated
Macrophages play a critical role in innate immunity by promoting or inhibiting tissue inflammation and repair. Classically, macrophages can differentiate into either pro-inflammatory (M1) or pro-reparative (M2) phenotypes in response to various stimuli. Therefore, this study aimed to address how extracellular vesicles (EVs) derived from polarized macrophages can affect the inflammatory response of tendon cells. For that purpose, human THP-1 cells were stimulated with lipopolysaccharide (LPS), and interleukins -4 and -13 (IL- 4, IL-13), to induce macrophages polarization into M1, M2, and hybrid M1/M2 phenotypes. Subsequently, the EVs were isolated from the culture medium by ultracentrifugation. The impact of these nanovesicles on the inflammation and injury scenarios of human tendon-derived cells (hTDCs), which had previously been stimulated with interleukin- 1 beta (IL-1ß) to mimic an inflammatory scenario, was assessed. We were able to isolate three different nanovesicles populations, showing the typical shape, size and surface markers of EVs. By extensively analyzing the proteomic expression profiles of M1, M2, and M1/M2, distinct proteins that were upregulated in each type of macrophage-derived EVs were identified. Notably, most of the detected pro- inflammatory cytokines and chemokines had higher expression levels in M1-derived EVs and were mostly absent in M2-derived EVs. Hence, by acting as a biological cue, we observed that M2 macrophage-derived EVs increased the expression of the tendon-related marker tenomodulin (TNMD) and tended to reduce the presence of pro-inflammatory markers in hTDCs. Overall, these preliminary results show that EVs derived from polarized macrophages might be a potential tool to modulate the immune system responses becoming a valuable asset in the
Summary Statement. The aim of this study was to compare patterns (aligned, random and grid) of electrospun polydioxanone scaffolds for
Thrombin has many biological properties similar to those of growth factors. In a previous study, we showed that thrombin improves healing of the rat tendo Achillis. Low molecular weight heparin (LMWH) inhibits the activity and the generation of thrombin. We therefore considered that LMWH at a thromboprophylactic dose might inhibit
Introduction. Tendon ruptures are a common injury and often require surgical intervention to heal. A refixation is commonly performed with high-strength suture material. However, slipping of the thread is unavoidable even at 7 knots potentially leading to reduced compression of the sutured tendon at its footprint. This study aimed to evaluate the biomechanical properties and effectiveness of a novel dynamic high-strength suture, featuring self-tightening properties. Method. Distal biceps tendon rupture tenotomies and subsequent repairs were performed in sixteen paired human forearms using either conventional or the novel dynamic high-strength sutures in a paired design. Each
The biomechanical evaluation of
Summary. Tissue grafts fail to recapitulate native tendon function, imposing the need for development of functional regeneration strategies. Herein, we describe advancements in
Introduction and Objective. Zone 2 flexor tendon injuries are still one of the challenges for hand surgeons. It is not always possible to achieve perfect results in hand functions after these injuries. There is no consensus in the literature regarding the treatment of zone 2 flexor tendon injuries,
Tendon injuries constitute a major healthcare burden owing to the limited healing ability of these tissues and the poor clinical outcomes of surgical repair treatments. Recent advances in tendon tissue engineering (TTE) strategies, particularly through the use of biotextile technologies, hold great promise toward the generation of artificial living tendon constructs. We have previously developed a braided construct based on suture threads coated with gelMA:alginate hydrogel encapsulating human tendon cells. These cell-laden composite fibers enabled the replication of cell and tissue-level properties simultaneously. Based on this concept, in this study we explored the use of platelet lysate (PL), a pool of supra-physiological concentrations of growth factors (GFs), to generate a hydrogel layer, which is envisioned to act as a depot of therapeutic factors to induce tenogenic differentiation of encapsulated human adipose stem cells (hASCs). For this purpose, commercially available suture threads were first embedded in a thrombin solution and then incubated in PL containing hASCs. Herein, thrombin induces the gelation of PL and consequent hydrogel formation. After coating suture threads with the mixture of PL-ASCs, cells were found to be viable and homogeneously distributed along the fibers. Strikingly, hASCs encapsulated within the PL hydrogel layer around the suture thread were able to sense chemotactic factors present in PL and to establish connections between adjacent independent fibers, suggesting a tremendous potential of PL cell-laden hydrogel fibers as building blocks in the development of living constructs aimed at
Introduction. Distal triceps tendon rupture is related to high complication rates with up to 25% failures. Elbow stiffness is another severe complication, as the traditional approach considers prolonged immobilization to ensure tendon healing. Recently a dynamic high-strength suture tape was designed, implementing a silicone-infused core for braid shortening and preventing repair elongation during mobilization, thus maintaining constant tissue approximation. The aim of this study was to biomechanically compare the novel dynamic tape versus a conventional high-strength suture tape in a human cadaveric distal triceps
Digital Ventilated Cages (DVC) offer an innovative technology to obtain accurate movement data from a single mouse over time [1]. Thus, they could be used to determine the occurrence of a tendon damage event as well as inform on tissue regeneration [2,3]. Therefore, using the mouse model of tendon experimental damage, in this study it has been tested whether the recovery of tissue microarchitecture and of extracellular matrix (ECM) correlates with the motion data collected through this technology. Mice models were used to induce acute injury in Achilles tendons (ATs), while healthy ones were used as control. During the healing process, the mice were housed in DVC cages (Tecniplast) to monitor animal welfare and to study biomechanics assessing movement activity, an indicator of the recovery of tendon tissue functionality. After 28 days, the AT were harvested and assessed for their histological and immunohistochemical properties to obtain a total histological score (TSH) that was then correlated to the movement data. DVC cages showed the capacity to distinguish activity patterns in groups from the two different conditions. The data collected showed that the mice with access to the mouse wheel had a higher activity as compared to the blocked wheel group, which suggests that the extra movement during tendon healing improved motion ability. The histological results showed a clear difference between different analyzed groups. The bilateral free wheel group showed the best histological recovery, offering the highest TSH score, thus confirming the results of the DVC cages and the correlation between movement activity and structural recovery. Data obtained showed a correlation between TSH and the DVC cages, displaying structural and movement differences between the tested groups. This successful correlation allows the usage of DVC type cages as a non-invasive method to predict tissue regeneration and recovery.
In the elderly population, chronic rotator cuff tears are often associated with high re-rupture rates after surgical tendon refixation. Implant materials, especially in combination with additives are supposed to positively influence healing outcome. Furthermore, adequate mechanical properties are crucial. In order to realize degradable implants with high specific surface area, polycaprolactone (PCL) was chosen as basic material and processed by electrospinning to achieve a high surface area for growth factor implementation and subsequent cell attachment. PCL (Mn approx. 80,000 g/mol) was used to generate fibre mats by electrospinning (relative collector velocity 8 m/s; flow rate of 4 ml/h). Mechanical analysis was performed according to EN ISO 527–2:2012 with test specimen 1BA (5 mm in diameter). Maximum force at failure (Fmax) as well as stiffness were evaluated. For preclinical in vivo testing, a coating with CS-g-PCL was performed to increase cellular adhesion and biological integration. Native and TGF-ß3 loaded mats were examined in a chronic rat tendon defect model with dissection of the M. infraspinatus, four week latency and following refixation at the humerus with different PCL-fibre mats (approval Nr. 33.12–42502–04–15/2015). After 8 weeks, rats were finalized and tendon-bone insertions were analyzed biomechanically and via histological methods.Introduction and Objective
Materials and Methods
Extensor mechanism and abductor reconstructions in total joint arthroplasty are problematic. Growing tendon into a metallic implant would have great reconstructive advantages. With the introduction of porous metal implants, it was hoped that tendons could be directly attached to implants. However, the effects of the porous metal structure on tissue growth and pore penetration is unknown. In this rat model, we investigated the effect of pore size on
Tendon tissue equilibrium very heavily depends on appropriate mechanical loading within a narrow, and still poorly defined, physiological range. We will present an overview of our recent work on the tendon cell-matrix interactions that drive tissue homeostasis, matrix remodelling and eventual tissue degeneration, and discuss a roadmap for unravelling these mechanically regulated signalling pathways for the development of effective treatment strategies. Our data suggest that tissue damage accumulates in the tendon until “intrinsic repair mechanisms” are overwhelmed. At this point, the metabolic cost of extracellular matrix remodeling exceeds the locally available nutrient supply. We hypothesize that upon reach
Tendon regeneration is complex since the scaffold has to bear high loads and stress concentrations, while providing suitable deformability. Previous studies demonstrated a physiological orientation of the fibers and good cell adhesion on electrospun polymeric scaffolds [1]. The aims of this work were to: (i) prepare and characterize electrospun resorbable scaffolds with different compositions and (ii) develop a process to produce a multiscale bundle assembly to mimic the hierarchical structure and biomechanical properties of a real tendon. We produced fibrous scaffolds made of blends of poly-L-lactic acid (PLLA) and collagen (Coll):
Pure PLLA; PLLA/Coll 75/25 w/w; PLLA/Coll 50/50 w/w. In order to prepare 3D bundles made of aligned fibres, we used a high-speed rotating collector. The electrospun nanofibers were deposited tangentially onto the drum, the electrospun layer was manually rolled transversely along the drum and then removed. The bundles were approximately 150 mm long and 300–450 mm in diameter. Five specimens were prepared and tested for each blend. To evaluate the mechanical properties of the bundles a tension test was applied with capstan grips on a testing machine with a 100N load cell, under the following conditions:
Gauge length: 20 mm. Monotonic ramp to break detection. Actuator speed 5 mm/min. For all the bundles, the stress-strain curve showed an initial non-linear part (toe region), similar to the laxity of the tendon at rest. The mechanical analysis confirmed the outstanding ductility and toughness of pure PLLA. Increasing the percentage of collagen resulted in a reduction of ductility. The PLLA/Coll 50/50 had a rather brittle behaviour. The values of mechanical properties found for the different compositions were slightly lower but of the same order of magnitude as tendon fibers (Failure stress: 33.7±19.2 MPa; Failure strain: 21.0±9.1 %; Young Modulus: 257±101 MPa [2]). The bundles made of pure PLLA had a failure stress of 13.2±0.8 MPa; failure strain of 84.7±9.4%; Young Modulus of 78.6±7.5 MPa. The bundles made of PLLA/Coll 50/50 had: failure stress of 10.5±1.5 MPa; failure strain of 21.4±2.7%, Young Modulus of 65.7±9.8 MPa. The most promising composition was the PLLA/Coll 75/25, with a failure stress of 14.0±0.7 MPa; failure strain of 40.3±2.2 %, Young Modulus of 98.6±12 MPa. We also tested bundles mechanical properties after aging samples in phosphate buffer at 37 °C for 48 hours, 7 and 14 days. After ageing, stress and strain values were progressively lower, while the toughness increased, compared to the dry samples. The promising results found in this work for the electrospun PLLA-collagen blends confirm their potential use for tendon tissue regeneration. This is a starting point for developing multiscale scaffolds mimicking the structure of tendon tissue, which can potentially be used in human regenerative medicine both as bioresorbable prosthesis, or inserted in a bioreactor for in vitro production of tendon tissue.
Intra-synovial tendon injuries affect compressed tendon within a synovial environment (eg Rotator cuff tears of the shoulder) and frequently demonstrate ‘failed healing'. Current therapeutic methods for tendon tears (intra-synovial corticosteroid medication and surgical debridement) offer poor outcomes and new strategies for enhancing repair are needed. We have therefore evaluated two different approaches involving the use of mesenchymal stem cells and scaffolds. Bone marrow- and synovial-derived stem cells were capable of adhering to cut surfaces of tendon in vitro and modulating the release of extracellular matrix into the media. However, when administered in vivo into the digital flexor tendon sheath in naturally-occurring deep digital flexor tendon tears in horses and in an experimental model in sheep, neither cell type was capable of healing the tendon defect. Superparamagnetic iron oxide particle labelling of the implanted cells imaged using MRI and histologically revealed that cells only engraft into the synovium. In contrast a non-cellularised bilayered electrospun and woven polydioxanone scaffold, when used in the same experimental sheep model via a modified open approach and sutured over the created defect resulted in no local or systemic signs of excessive inflammation 3 months after implantation. All the tendon lesions healed with only a mild local inflammatory reaction and minimal-to-mild adhesion formation. Significant proliferative fibroblast infiltration was observed within and immediately adjacent to the implanted scaffold. The cellular infiltrate was accompanied by an extensive network of new blood vessel formation within the new tissue. In conclusion, the use of a scaffold to cover the defect appears to be a more successful strategy to
Frictional resistance to tendon gliding is minimised by surrounding loose areolar tissues. During periods of prolonged immobilisation, for example post tendon-repair, adhesions can form between the two adjacent tissues, thereby limiting function. Whilst agents applied during surgery are recognised to succeed in adhesion prevention, they have also been reported to provide some reduction in friction during
The fibrocartilaginous enthesis displays a complex interface between two mechanically dissimilar tissues, namely tendon and bone. This graded transition zone consists of parallel collagen type I fibres arising from the tendon and inserting into bone across zones of fibrocartilage with aligned collagen type I and collagen type II fibres and mineralised fibrocartilage. Due the high stress concentrations arising at the interface, entheses are prone to traumatic and chronic overuse injuries such as rotator cuff and anterior cruciate ligament (ACL) tears. Treatment strategies range from surgical reattachment for complete tears and conservative treatments (physiotherapy, anti-inflammatory drugs) in chronic inflammatory conditions. Generally, the native tissue architecture is not re-established and mechanically inferior scar tissue is formed. Current interfacial tissue engineering approaches pose scaffold-associated drawbacks and limitations, such as foreign body response. Using a thermo-responsive electrospun scaffold that provides architectural signals similar to native tissues and can be removed prior to implantation, we aim to develop an ECM-rich, cell-based implant for tendon-enthesis regeneration. Alcian blue staining revealed highest sGAG deposition in cell (human adipose derived stem cells) sheets grown on random electrospun fibres and lowest sGAG deposition in collagen type I sponges. Cells did not show an equal distribution throughout the collagen type II scaffolds but tended to form localised aggregates. Thermo-responsive electrospun fibres with random and aligned fibre orientation provided an adequate three-dimensional environment for chondrogenic differentiation of multilayer hADSC-sheets shown by high ECM-production, especially high sGAG deposition. Chondrogenic cell sheets showed increased expression of SOX9, COL2A1, COL1A1, COMP and ACAN after 7 days of chondrogenic induction when compared to pellet culture. Anisotropic fibres enabled the generation of aligned chondrogenic cell sheets, shown by cell and collagen fibre alignment. Thermoresponsive electrospun fibres showed high chondro-inductivity due to their three-dimensionality and therefore pose a promising tool for the generation of scaffold-free multilayer constructs for tendon-enthesis repair within short culture periods. Aligned chondrogenic cell sheets mimic the zonal orientation of the native enthesis as the fibrocartilaginous zone exhibits high collagen alignment.
Tendon injuries occur frequently in athletes and the general population, with inferior healing leading to deposition of fibrotic scar tissue. New treatments are essential to limit fibrosis and enable tendon regeneration post-injury. In this study, we tested the hypothesis that rapamycin improves