Advertisement for orthosearch.org.uk
Results 1 - 20 of 433
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 1 - 1
1 Mar 2022
Lacey A Chiphang A
Full Access

16 to 34% of the population suffer from shoulder pain, the most common cause being rotator cuff tears. NICE guidance recommends using ultrasound scan (USS) or MRI to assess these patients, but does not specify which is preferable. This study assesses the accuracy of USS and MRI in rotator cuff tears in a DGH, to establish the most appropriate imaging modality. Patients who had at least two of shoulder ultrasound, MRI or arthroscopy within a seven month period (n=55) were included in this retrospective study. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated using arthroscopy as the true result, and kappa coefficients calculated for each pairing. 59 comparisons were made in total. Sensitivity for MRI in full supraspinatus tears was 0.83, and for USS 0.75. Specificity for MRI in these tears was 0.75, and for USS 0.83. Values were much lower in other tears, which occurred less frequently. USS and MRI completely agreed with each other 61.3% of the time. Both modalities were only completely accurate 50% of the time. Kappa coefficient between arthroscopy and MRI for supraspinatus tears was 0.658, and for USS was 0.615. There was no statistical difference between MRI and USS sensitivity or specificity (p=1), suggesting that one modality cannot be recommended over the other for full supraspinatus tears. They also do not tend to corroborate one another, suggesting that there is no benefit from doing both scans. Further research is needed to see how both modalities can be improved to increase their accuracy


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 47 - 47
1 Aug 2017
Barrack R
Full Access

The role of metal sensitivity or allergy in causing persistent symptoms or failure and need for a revision of a total joint replacement has been the topic of debate and controversy for decades. There was renewed interest in this area with the rise of metal-on-metal hip arthroplasty and the advent of adverse local tissue reactions. This led to an increase in metal ion testing as well as metal sensitivity testing. With the decline of the use of metal-on-metal hip components, this is now mostly an issue in knee arthroplasty. It is well known that a substantial percentage of patients have persistent symptoms following knee replacement. What remains in question is whether allergy to metal or other materials such as PMMA may be a contributing factor. It is accepted that the incidence of positive skin patch tests is higher in symptomatic failed joint replacements. Nickel sensitivity is most common as a positive skin test with up to 15% of patients demonstrating this followed by chromium and cobalt. A recent review by Lachiewicz et al. concluded that there was insufficient evidence to recommend routine or widespread cutaneous or in vitro hypersensitivity testing before primary TKA, that there is no evidence-based rationale to recommend a routine metal allergy screening questionnaire, that there is only anecdotal support for Ni-free implants, and that local dermatitis should be treated with topical steroids. In another article, routine screening for metal allergy was not recommended, however, selective screening for history of sensitivity or unexplained pain or early loosening was suggested. Other experts have recommended a role for utilizing a commercially available alternative to components containing nickel or cobalt in patients thought to be hypersensitive. A recent study, however, concluded that there was no difference in complications, revisions, or reoperations among patients who tested positive with patch testing whether they were treated with standard components or nickel free components. Likewise, a consensus panel published results from the United Kingdom in which cobalt chrome implants were recommended regardless of the patients metal allergy status. Patient perception is important, however, and among patients who report multiple allergies of any kind, a higher percentage are likely to be dissatisfied with their knee replacement. Of more importance are those reporting a specific allergy to metal are substantially more likely to express some dissatisfaction with their components. Metal allergy as a cause of chronic pain and/or early failure of joint replacement is rare if it exists at all. It is always a diagnosis of exclusion. Patients who think they are allergic are probably more likely to be more symptomatic following joint replacement. Whether or not to use a nickel free or hypoallergenic component in such patients remains an area of controversy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 75 - 75
1 May 2012
Bucknill A Yam T Campton L Robertson P de Steiger R
Full Access

FAI has been implicated in the progression of osteoarthritis (OA) and early detection may allow for treatment, which can slow or halt progression. FAI is a difficult condition to image and there is little objective evidence about imaging accuracy. We aim to measure the accuracy of five imaging modalities. Three blinded observers retrospectively reviewed five different modalities from two age and sex matched groups: A patient group referred to the outpatient clinic with a clinical diagnosis of FAI and a control group who had had CT scans of the pelvis for suspected trauma, where the Pelvic scan had been reported as showing no injuries. The imaging modalities were: Standard x-ray; Antero-Posterior, Lateral; Condition-specific x-ray projections; Dunn view, lateral internal rotation; Standard Computer Tomography (CT) multiplanar reconstruction (MPR); axial, sagittal and coronal; Condition-specific CT MPR; angled axial, angled coronal; 3D modelling; and surface rendered dynamic. We found marked variations in the sensitivity, specificity, Positive Predictive Value (PPV) and Negative Predictiive Value (NPV) for each of the following imaging modalities: Standard X-ray; Sensitivity 51.9; Specificity; 57.1; PPV; 40; NPV; 68.3 Special X-rays; Sensitivity; 66.7; Specificity; 57.1; PPV; 46.1; NPV; 75.7. Standard CT MPR; Sensitivity; 40.7; Specificity; 75.5; PPV; 47.8; NPV; 69.8 Special CT MPR; Sensitivity; 48.1; Specificity; 57.1; PPV; 46.4; NPV; 70.8 Dynamic 3D CT models; Sensitivity; 55.6; Specificity; 69.3; PPV; 42.8; and NPV; 71.8. The Dynamic 3D CT models (where the observer can manipulate the model in real time three dimension to control the perspective) proved to be the most accurate, closely followed by the special X-Ray views, which were also the most sensitive. The Standard CT MPRs were the most specific but had a low sensitivity. This is the first study to measure sensitivity, specificity and PPV and NPV for these imaging modalities in FAI. We recommend the use of condition-specific X-Ray views as well as 3D CT Models for optimal imaging accuracy in this condition. Standard X-Ray views and CTs proved less useful


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 5 - 5
1 Jan 2016
Goto K Kitamura N Kondo E Yokota M Wada S Thoyama H Yasuda K
Full Access

Introduction. Metals used for total knee arthroplasty (TKA) are well known for their good biocompatibility, but may be a source of a release of metal ions that can be a cause of local and systemic adverse effects, aseptic loosening, and hypersensitivity reactions. One of the major difficulties in performing TKA is the selection of implants for patients who are preoperatively diagnosed as subject to metal sensitivity. Alternative solutions in cases of hypersensitivity are implants without metal constituents or metallic implants treated with a non-sensitive surface process. The aim of this study was to evaluate clinical results in patients who had been preoperatively diagnosed with metal sensitivity and who subsequently were provided with the zirconia-ceramic LFA-III TKA, and with a minimum 5-year follow-up. Methods. Five patients (8 knees) with metal sensitivity underwent TKA using cemented zirconia-ceramic LFA-III implants. The LFA-III implant (KYOCERA Medical Co., Japan) is composed of a zirconia ceramic femoral component and a titanium-alloy tibial component with a polyethylene insert. All patients were female andthe average age at the time of surgery was 76.1 years. The average follow-up time was 7.2 years. Clinical and radiographic assessments were conducted with the Knee Society scoring system. Results. No patients except one who had palmoplantar pustulosis preoperatively presented systemic or local dermatitis after surgery. The mean preoperative range of motion of 97.6 degrees improved to a mean of 110.7 degrees at the time of the most recent follow-up. The mean postoperative knee and function scores were 77.1 and 66.9, respectively. Subtle periprosthetic radiolucencies were found in 2 knees after the surgery. Discussion. The zirconia-ceramic LFA-III TKA has performed well over a 5-year period in patients with metal hypersensitivity. Although this implant has a metal tibial component made of titanium, no systemic or local adverse events related to metal hypersensitivity were recorded. Ceramic implants can be an attractive alternative solution for patients suffering from hypersensitivity reactions to metals


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 36 - 36
1 Dec 2015
Lepetsos P Stylianakis A Leonidou A Argyris D Anastasopoulos P Lelekis M Tsiridis E Macheras G
Full Access

In spite of its incidence decreasing to 1% nowadays, prosthesis-related infections remain a research, diagnostic, therapeutic and cost-related problem. Early diagnosis, selection of an appropriate surgical strategy, accurate identification of the responsible microorganisms and construction of an appropriate antibiotic regimen are essential elements of any management strategy. Our study aim was firstly to compare the diagnostic accuracy of conventional periprosthetic tissue culture and culture of fluid derived from vortexing and bath sonication of the explanted hardware and secondly to investigate the role of possible metabolic factors affecting the sensitivity of the sonication method. We investigated 70 patients undergoing revision hip or knee arthroplasty because of loosening of the prostheses, at our institution, between October 2011 and November 2013. Patients’ medical history and demographic characteristics were recorded. We compared the culture of samples obtained by sonication of explanted hip and knee prostheses with conventional culture of periprosthetic tissue for the microbiological diagnosis of prosthetic-joint infection. Infectious Diseases Society of America (IDSA) Guidelines were used for the definition of prosthetic-joint infection. Thirty-two patients had septic loosening and 38 aseptic loosening (48 hip prostheses and 22 knee prostheses). The sensitivity of sonication fluid culture was 81.25% and the sensitivity of conventional tissue cultures was 56.25% (p-value = 0.043). The sensitivity of the sonication method was statistically higher in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis (p-values < 0.05). The sonication method represents a reliable test for the diagnosis of prosthetic – joint infections with a greater sensitivity than the conventional periprosthetic tissue cultures, especially in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1256 - 1260
14 Sep 2020
Kader N Clement ND Patel VR Caplan N Banaszkiewicz P Kader D

Aims. The risk to patients and healthcare workers of resuming elective orthopaedic surgery following the peak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been difficult to quantify. This has prompted governing bodies to adopt a cautious approach that may be impractical and financially unsustainable. The lack of evidence has made it impossible for surgeons to give patients an informed perspective of the consequences of elective surgery in the presence of SARS-CoV-2. This study aims to determine, for the UK population, the probability of a patient being admitted with an undetected SARS-CoV-2 infection and their resulting risk of death; taking into consideration the current disease prevalence, reverse transcription-polymerase chain reaction (RT-PCR) testing, and preassessment pathway. Methods. The probability of SARS-CoV-2 infection with a false negative test was calculated using a lower-end RT-PCR sensitivity of 71%, specificity of 95%, and the UK disease prevalence of 0.24% reported in May 2020. Subsequently, a case fatality rate of 20.5% was applied as a worst-case scenario. Results. The probability of SARS-CoV-2 infection with a false negative preoperative test was 0.07% (around 1 in 1,400). The risk of a patient with an undetected infection being admitted for surgery and subsequently dying from the coronavirus disease 2019 (COVID-19) is estimated at approximately 1 in 7,000. However, if an estimate of the current global infection fatality rate (1.04%) is applied, the risk of death would be around 1 in 140,000, at most. This calculation does not take into account the risk of nosocomial infection. Conversely, it does not factor in that patients will also be clinically assessed and asked to self-isolate prior to surgery. Conclusion. Our estimation suggests that the risk of patients being inadvertently admitted with an undetected SARS-CoV-2 infection for elective orthopaedic surgery is relatively low. Accordingly, the risk of death following elective orthopaedic surgery is low, even when applying the worst-case fatality rate. Cite this article: Bone Joint J 2020;102-B(9):1256–1260


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 39 - 39
1 Dec 2013
D'Alessio J Eckhoff D Kester M
Full Access

Computational modeling has been used to simulate the natural and prosthetic kinematic and kinetic function in an attempt to compare designs and/or predict a desired motion path from a design. The levels of soft tissue can range from basic ligaments (MCL, LCL, and ACL & PCL) to more complex models. The goal of this study was to evaluate the sensitivity of the Posterior Cruciate ligament in a virtual model and its effects on the kinematic outcome in a commercially available and validated kinematics package (KneeSim, LifeModeler San Clemente, CA). Methods:. KneeSIM is a musculoskeletal modeling environment that is built on the foundation of the ADAMS (MSC Software, Santa Ana CA), a rigid body dynamics solver to compute knee kinematics and forces during a deep knee bend. All parameters are customizable and can be altered by the user. Generic three dimensional models of cruciate retaining components of the femoral, tibial, and patellar are available with the software and were used to provide a common reference for the study. The following parameters were modified for each simulation to evaluate the sensitivity of the PCL in the model: 1) Model without PCL, 2) PCL with default properties, 3) PCL Shifted at femoral origin, 7 mm anterior, 7 mm inferior; tibial origin maintained; 4) PCL with increased stiffness properties (2x default), 5) position in the femur and tibia remained default position and 6) PCL with default properties and location, joint line shifted 4 mm superior. The standard output of tracking the flexion facet center (FFC) motion of the medial and lateral condyles was utilized (Figure 1). Results:. Figure 2 and 3 displays the output of the six conditions tested above. Comparing the curves for the medial and lateral motion show different patterns with the lateral point having more posterior translation than the medial. After approximately 95° of flexion, all cases exhibit an anterior translation in the model. This motion was consistent for all test cases. The model showed no difference with motion either with or without the PCL and with changing the stiffness. Altering the location of the PCL on the femoral insertion had the greatest effect on motion, while shifting the joint line superior was second. The shift of the ligament insertion and changing of the joint line results in the ligament being more parallel to the tibial surface which provides resistance to anterior motion or posterior translation. Discussion:. Although the model was able to discern differences, the inability to highlight variation in motion with and without the PCL suggests that the default parameters are not representative of an experimental or clinical setup. Although it is apparent that KneeSim can be used for comparative assessments between designs, simulations should be designed so as to provide similar boundary conditions. Publications (Colwell et al 2011) did successfully use KneeSim to provide a comparative assessment of CR components; however, only after the default model was altered to match the outcome of the experimental rig. Further analysis of the complexities in soft tissue modeling is warranted


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 94 - 94
1 Feb 2017
Deck J White B
Full Access

The kinematic and kinetic characteristics of the knee after TKR are known to be strongly influenced by the alignment and positioning of the implanted components. In this paper we apply a virtual multi-fiber ligament model to a rigid body model of the post-surgical knee to explore how variations in alignment and positioning affect the predicted behavior of the ligaments and contact forces. We vary the angular and translational positioning of the femoral and tibial TKR components relative to the bone. Meanwhile the proximal and distal insertion sites of the ligaments are held constant relative to the bony structures. We evaluate sensitivity of the ligament balance and peak ligament tension through the passive flexion arc in response to the variation in positioning and alignment of the TKR components. With further development, this work holds the promise of applications in surgical planning and virtual arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 26 - 26
1 May 2016
Mauck J Kebbach M Schulze C Bader R Kluess D
Full Access

Introduction. The influence of the bone mineral density (BMD) on the mechanical behavior of bones can be examined using computer tomography (CT) data and finite element (FE) simulations, because the BMD correlates with the Hounsfield scale (HU) of the CT data. Therefor the material mapping strategy, which is required to assign the HU values to the FE mesh, is of crucial importance. In this study a nodal mapping strategy was analyzed concerning its sensitivity towards FE mesh parameters and an averaging of HU values from the area around the respective nodes. Method. The FE simulation is based on CT data of a human proximal femur. Once the bone shape was reconstructed, the resulting model was meshed with quadratic tetrahedral elements in ABAQUS/CAE and all nodes were assigned an HU value from the CT data by using the respective node coordinates. In this process, the mesh density, the threshold, which could be used to exclude connective tissue and fat from the material mapping process, the considered volume around the nodes and the method of averaging were varied. The material assignment was realized by an HU value dependent, linear elastic material definition. The femur model was clamped at the level of the isthmus and a displacement of 0.5 mm was applied at the femoral head. The evaluation was based on the resulting reaction forces. Results. The sensitivity analysis demonstrated, that threshold and mesh density mainly influenced the reaction force [Fig. 1]. If a threshold was applied, the reaction force increased by about 20 % in average. A threefold increase of the mesh density led to an average gain of the results of about 24 %. For a specific mesh density the curve progressions of the respective results intersected, i.e. an alteration of the considered volume or the method of averaging barely affected the reaction force [Fig. 2, Fig. 3]. Apart from this intersection, the comparison of the small and the large average volume led to a deviation of up to 11 %. On the other hand, the examination of different methods of averaging revealed only a maximum deviation of 4 % between “mean” and “median”. Discussion. The present study indicates, that the material mapping strategy is an influential part of the modeling process, which should be validated to avoid misjudgments of the load situation. Accordingly, the use of a threshold to exclude non-bone tissue could be a helpful tool. But with the exclusion of lower HU values, the load-bearing structure gains stiffness and the reaction force in the femur rises. A finer mesh leads to a higher resolution of the bone structure and, therefore, to a higher accuracy of the results. The “equilibrium” between the different models at the intersection is caused by a more homogeneous distribution of the material property which is increased by a larger considered volume and the method “mean”


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 15 - 15
1 Sep 2012
Macnair R Wimhurst J Jones HW Cahir J Toms A
Full Access

ARMD (Adverse Reaction to Metal Debris) is an increasingly recognised complication of metal on metal hip replacements. The MHRA (Medical and Healthcare Related Devices Agency) have advised a blood cobalt or chromium level above 7 mg/L is a threshold for further investigation, stating that “low levels are reassuring and strongly predict not having an adverse outcome”. Cross-sectional imaging should be performed when levels are above 7 mg/L. We have performed a study investigating the specificity and sensitivity of chromium and cobalt metal ion levels as a screening measure for ARMD. 79 ASR hip replacements were performed at our hospital and 75 (95%) of these underwent a Metal Artefact Reduction Sequence (MARS) MRI scan. All patients (64 hips) who had not undergone revision were invited to take part in this study. 57 patients with 62 hip replacements completed hip and activity scores, had blood cobalt and chromium ion level measurements and 3D-CT to measure acetabular component position. Acetabular component inclination (>50 degrees), small head size (< 51mm) and female gender were significantly correlated with raised chromium (Cr) and cobalt (Co) ion levels. An ARMD was detected using MRI in 18 (29%) of the hips in this study. The incidence of ARMD was significantly higher when chromium concentration was above 7 mg/l (p = 0.02). Chromium ion levels >7 mg/L had a sensitivity of 56% and specificity of 83% for ARMD, and cobalt ion levels >7 mg/L 56% and 76% respectively. 40 patients had cobalt levels <7 mg/L and 33 had chromium levels <7 mg/L, but 8 of these had an ARMD on MRI. All 8 patients had minimal symptoms (Oxford Hip Score ≥ 44 out of 48). The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended that cobalt and chromium levels be measured in patients with a metal-on-metal hip replacement and cross-sectional imaging performed when these levels are above 7 μg/L. This study has shown that by using this threshold, in patients with this implant combination, the sensitivity and specificity for the detection of ARMD is low and patients with soft tissue disease may be missed. Furthermore the presence of MRI detected ARMD, in the absence of significant clinical symptoms and with metal ion levels <7 μg/L is of concern. MoM implants at risk of failure are associated with raised cobalt and chromium levels. However metal ion analysis alone is not reliable as a screening tool for ARMD, which is often clinically “silent”. We recommend the routine use of MARS MRI as the safest method of ARMD diagnosis in patients with MoM implants


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 40 - 40
1 Apr 2018
Kanojia R
Full Access

The evolution of orthopedic implants has witnessed a great evolution and allowed insights into the various metals and alloys compatible with the human body. However, some recent reports have raised concerns regarding hypersensitivity to several metals used in orthopedic implants. These cases are mostly documented in the field of arthroplasty.

Metal ion release following hip or knee arthroplasty is a known phenomenon and associated immune reactions to these metal ions have been implicated in the causation of these hypersensitivity reactions. These reactions frequently lead to poor outcome following these implant surgeries. We here present two rare cases of metal induced hypersensitivity reactions following orthopedic surgeries. We have also reviewed the literature in this context to look into the various causes of metal reactions, types of implant involved in hypersensitivity, methods of testing and management options in these cases.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim. Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Method. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity. Results. A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA. Conclusions. The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 78 - 78
1 Dec 2022
Dilernia FD Watson D Heinrichs D Vasarhelyi E
Full Access

Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus. SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated the sensitivity to killing, comparing WT and CopAZB-deficient USA300 strains. UAMS-1 evidenced a greater sensitivity to SF when compared to USA300 WT, at 12 (p=0.001) and 24 hours (p=0.027). UAMS-1 significantly died at 24 hours (p=0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at 4 (p=0.001), 12 (p=0.005) and 24-hours (p=0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at 4 (p=0.011), 12 (p=0.011), and 24 hours (p=0.011). Both WT and CopAZB-deficient USA300 strains significantly died in SF, evidencing a MBC-Cu of 50µM against USA300 WT (p=0.011). SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. The addition of 10µM of copper was highly toxic for both strains, confirming its bactericidal effect. We evidenced CopAZB-proteins involvement in copper effluxion by demonstrating the high sensitivity of the mutant strain to lower copper concentrations. Thus, we propose CopAZB-proteins as potential targets and the use of exogenous copper as possible treatment alternatives against S. aureus


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 30 - 30
1 Nov 2022
Barakat A Ahmed A Ahmed S White H Mangwani J
Full Access

Abstract. Background. Distinction between foot and ankle wound healing complications as opposed to infection is crucial for appropriate allocation of antibiotic therapy. Our aim was to evaluate the diagnostic accuracy of white cell count (WCC) and C-reactive protein (CRP) as diagnostic tools for this distinction in the non-diabetic cohort. Methods. Data were reviewed from a prospectively maintained Infectious Diseases Unit database of 216 patients admitted at Leicester University Hospitals – United Kingdom between July 2014 and February 2020 (68 months). All diabetic patients were excluded. For the infected non-diabetic included patients, we retrospectively retrieved the inflammatory markers (WCCs and CRP) at the time of presentation. Values of CRP 0–10 mg/L and WCC 4.0–11.0 ×109 /L were considered normal. Results. 25 patients met our inclusion criteria. Infections were confirmed microbiologically with positive intra-operative culture results. 7 (28%) patients with foot osteomyelitis (OM), 11 (44%) with ankle OM, 5 (20%) with ankle septic arthritis, and 2 (8%) patients with post-surgical wound infection were identified. Previous bony surgery was identified in 13 (52%) patients. 21 (84%) patients did have raised inflammatory markers while 4 (16%) patients failed to mount an inflammatory response even with subsequent debridement and removal of metalwork. CRP sensitivity was 84%, while WCC sensitivity was only 28%. Conclusion. CRP had good sensitivity, whereas WCC is a poor inflammatory marker in the detection of such cases. In presence of a clinically high level of suspicion of foot or ankle infection, a normal CRP should not rule out the diagnosis of OM


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 57 - 57
1 Oct 2022
Young B Dudareva M Vicentine M Hotchen A McNally M
Full Access

Aim. We reviewed a cohort of individuals with recurrent orthopaedic infection to describe the relative rates of microbial persistence vs re-infection at recurrence surgery. Method. A cohort of 125 individuals with recurrent infection (prosthetic joint infection, fracture-related infection and osteomyelitis) from two centres in the UK between 2007 and 2021. Electronic patient records were reviewed to identify culture results from surgical samples at index surgery and the next operation for recurrent infection. Antibiotic sensitivity results were recorded as sensitive, intermediate or resistant according to contemporary sensitivity testing guidelines. Results. Among patients with recurrent infection, 78/125 (62.4%) were male, with a median age 64 years (IQR 51–73y). 76 had prosthetic joint infection, and 49 had fracture related infection or osteomyelitis. Culture results at index procedure showed the most frequently isolated species were Staphylococci (Table 1). A single species was isolated in 75/125 (60%) and mixed species in 36/125 (28.8%). No organisms were cultured in 14/125 (11.2%). At re-operation 48/125 (38.4%) individuals had an organism from the same species or group as at the index operation. In 49/125 (39.2%), none of the organisms isolated at re-operation were grown at first operation. In 28/125 (22.4%), re-operative cultures yielded no growth. For each species isolated at the index procedure, the proportion with the same, different or no organisms isolated at the next procedure were reviewed (Table 1). Staphylococci (including S. aureus and coagulase-negative staphylococci) and Pseudomonas species showed the highest rate of persistence at the species level. Among coagulase-negative staphylococci, changes in antimicrobial sensitivity that make it unclear if these infections were truly persistent, or represented re-infection. Conclusions. Infection with different organisms was seen at similar rates (39.2% vs 38.4%) to persistent infection with the same species in this cohort. Staphylococcus aureus is the organism most likely to be persistently identified in recurrent infections


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 48 - 48
1 Jun 2023
Lynch-Wong M Breen N Ogonda L
Full Access

Materials & Methods. Chronic osteomyelitis is a complex and challenging condition the successful treatment of which requires a specialist multidisciplinary approach. Prior to tertiary referral to a specialist Orthoplastic Unit, patients often receive multiple courses of antibiotics, in usually unsuccessful attempts, to eradicate infection. This often results in the development of chronic polymicrobial infection. We reviewed the intra-operative cultures of patients treated in our Orthoplastic unit over a 9-year period from 2012–2021 to determine the spectrum of polymicrobial cultures and the relationship to pre-operative cultures. Results. We reviewed the electronic care records and laboratory results of all patients referred to or directly admitted to our unit with a diagnosis of chronic osteomyelitis between 2012–2021. We checked all culture results, antibiotic sensitivities and prescription for treatment. We also checked for any recurrence of infection within 1 year. 60 patients were treated over the 9-year period. 9 upper and 51 lower limbs. The most common referral sources were from the surgical specialties of Trauma & Orthopaedics and Plastic Surgery (62%) while an equal amount came from the Emergency Department and other inpatient medical teams, each making up 15%. A small cohort (8%) developed the infection while still being followed up post fixation. Aetiology of Infection were post fracture fixation 41 (68%), spontaneous osteomyelitis 10 (17%), soft tissue infection 4 (7%). The remaining 5 patients (8%) had a combination failed arthroplasty, arthrodesis and chronic infection from ring sequestrum. 58 patients (97%) had positive cultures with 26 being polymicrobial. 12 cultures were gram negative (G-ve), 11 G+ve 12, 4 anaerobic and 1 Fungal. In 24 patients (40%) the pre-operative cultures and antibiotic sensitivities did not correspond to the intra-operative cultures and sensitivities. 55 patients (92%) required dual or triple therapy with 8% requiring further debridement and extended therapy. 2 (3%) patients had failed treatment requiring amputation. Conclusions. Chronic osteomyelitis is a complex and challenging condition the successful treatment of which requires early referral to a specialist Orthoplastic unit. Less than half of organisms cultured pre-operatively reflect the causative organisms cultured intra-operatively with 52% of these infections being polymicrobial. After initial treatment, 8% of patients will require a further combination of extended antibiotic therapy and surgery to eradicate infection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 44 - 44
1 Oct 2022
Young B Dudareva M Vicentine M Hotchen A McNally M
Full Access

Aim. Local antibiotic treatment for bone and joint infections offers direct delivery of high concentrations of antibiotics with reduced systemic exposure and favourable safety profile. However, the possibility of prolonged release of antibiotics at sub-therapeutic levels creates concern about the possible development of antimicrobial resistance. We investigated patients with recurrent bone and joint infection for evidence of antimicrobial resistance emerging from the use of local antibiotics. Method. 125 patients with recurrent infection (prosthetic joint infection, fracture related infection and osteomyelitis) in the UK between 2007 and 2021 were identified. Electronic patient records (including operative notes, pathology results and prescriptions) were reviewed to extract site of infection, date of surgery, the use of local antibiotics, culture results, empiric and definitive antibiotic therapy. All antibiotic sensitivity results were recorded as sensitive, intermediate or resistant according to contemporary guidelines (BSAC and EUCAST). Results. Local antibiotics were used in 74/125 (59.2%) of patients. Agents used were Gentamicin 53/125 (42.4%), Tobramycin 18/125 (14.4%), and vancomycin in 19/125 (15.2%). Combined gentamicin and vancomycin usage was seen in 16/125 patients (12.8%). Gentamicin non-sensitivity was common in this cohort with frequent aminoglycoside use. At index procedure, a Gentamicin non-sensitive organism was cultured in 51/125 patients (40.8%). At re-operation this proportion was lower: 40/125 (32%). There was no statistically significant difference in the rate of Gentamicin resistance at reoperation comparing patients who previously received local aminoglycosides with those who had not (21/71, 29.8% vs 19/54, 35.2% p=0.6, chi-squared test). In 48/125 (38.4%) of patients, the same species was isolated during the index and recurrence surgery. We identified 7 cases with new aminoglycoside resistance arising at the second procedure. In 2/7 – S. aureus and E. faecalis - aminoglycoside resistance was the only change in antimicrobial sensitivity. In 5/7, there were at least 2 additional changes in observed antimicrobial sensitivity. 3/74 (4%) of cases who initially received local aminoglycoside cultured organisms with aminoglycoside resistance at recurrence. 4/51 (7.8%) of those who did not receive local or systemic aminoglycoside at index surgery cultured resistant organisms (chi square 0.82; p=0.365). Conclusions. As a group, patients whose treatment for orthopaedic infection included local antibiotics did not exhibit higher rates of specific antimicrobial resistance compared with those not treated with local antibiotics. However we did identify cases where Gram positive bacteria developed aminoglycoside resistance regardless of their initial antimicrobial therapy. This should be considered in antimicrobial choice during surgery for recurrence


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 20 - 20
1 Dec 2021
Schwarze J Theil C Gosheger G Lampe L Schneider KN Ackmann T Moellenbeck B Schmidt-Braekliing T Puetzler J
Full Access

Aim. Diagnosis and isolation of a causative organism is imperative for successful treatment of periprosthetic joint infections (PJI). While there are several diagnostic algorithms using microbiology, serum and synovial markers, the preoperative diagnosis of a low-grade infection remains a challenge, particularly in patients with unsuccessful aspiration. An incisional biopsy may be used in these cases as additional diagnostic tool. In this retrospective study we evaluated microbiological findings, sensitivity, and specificity of open synovial biopsies in cases of inconclusive preoperative diagnostics. Methods. In a retrospective databank analysis (2010–2018), we identified 80 TKAs that underwent an open biopsy because of inconclusive results after applying the CDC Criteria (2010) or the MSIS (2011–2018) for PJI. Infection makers in the serum (C-reactive protein [CRP], leucocytes count and interleukin-6 [IL-6]) and in the synovial aspirate (leucocyte count, percentage of neutrophiles) prior to the biopsy were analyzed. All biopsies were performed by suprapatellar mini-arthrotomy. If a subsequent revision surgery was performed, the isolated organisms in the open biopsy were compared to the results in the revision surgery and sensitivity and specificity were calculated. Serum markers were checked for correlation with a positive result in the open biopsy using Cramer-V and Chi. 2. -Test. Results. A positive result in the open biopsy occurred in 32 cases (40%) while 48 cases (60%) showed no growth of microorganisms. A preoperative elevated serum CRP (≥1mg/dl) showed a significant correlation for a positive biopsy (p=0.04). The odds ratio for a positive biopsy was 2.57 (95% CI 1.02–6.46) with elevated serum CRP. A revision surgery of the TKA with additional tissue sampling was performed in 27 (84%) cases with a positive biopsy and in 32 (67%) cases with a negative biopsy. The intraoperative tissue samples from the revision surgery showed microbial growth in only 52% of cases that were believed to be culture positive from the biopsy results, while positive cultures occurred in 41% of the cases with an initially negative biopsy. Patients with ≥ two cultures of the same microorganism in the biopsy presented a positive result in 73% of their revision surgeries. The open biopsy showed a sensitivity of 48% with a specificity of 62% in our collective if revision surgery was performed. Conclusion. Open biopsy may be considered with inconclusive preoperative serum and synovial fluid diagnostics for PJI, but sensitivity and specificity were rather low in this special collective. Further studies with bigger collectives should be performed to determine potential markers with a higher sensitivity