Introduction. Re-revision due to instability and dislocation can occur in up to 1 in 4 cases following
Background. Standard preoperative protocols in total joint arthroplasty utilize the International Normalized Ratio (INR) to determine patient coagulation profiles. However, the relevance of preoperative INR values in joint arthroplasty remains controversial. Acceptable INR cutoff values for joint replacement are inconsistent, and are often based on studies of primary arthroplasty, or even non-orthopedic procedures. This analysis examined the relationship between preoperative INR values and post-operative outcomes in
Instability and aseptic loosening are the two main complications after
Background. Failed ingrowth and subsequent separation of revision acetabular components from the inferior hemi-pelvis constitutes a primary mode of failure in
Aim. The aim of this study is to evaluate if obesity negatively affects: (1) complication rate, (2) reoperation and revision rate and (3) functional outcome (based on patient reported outcome measures, PROMs) in
Introduction. Highly cross-linked polyethylene has been introduced to decrease osteolysis secondary to polyethylene wear debris generation, but there are few long-term data on
Acetabular reconstruction of extensive bone defect is troublesome in
Introduction. Modular tapered implants have been suggested as the optimal treatment in patients with severe femoral bone loss undergoing
Aims. Severe, superior acetabular bone defects are one of the most challenging aspects to
Aims.
Introduction. As the proximal femoral bone is generally compromised in failed total hip arthroplasty, achievement of solid fixation with a new component can be technically demanding. Clinical studies have demonstrated good medium-term results after
THA in patients with acetabular bone defects is associated with a high risk of dislocation. Dual mobility (DM) cups are known to prevent and treat chronic instability. The aim of this study was to evaluate the dislocation rate and survival of jumbo DM cups. This was a retrospective, continuous, multicenter study of all the cases of jumbo DM cup implantation between 2010 and 2017 in patients with acetabular bone loss (Paprosky 2A: 46%, 2B: 32%, 2C: 15% and 3A: 6%). The indications for implantation were revisions for aseptic loosening of the cup (n=45), aseptic loosening of the femoral stem (n=3), bipolar loosening (n=11), septic loosening (n=10), periprosthetic fracture (n=5), chronic dislocation (n=4), intraprosthetic dislocation (n=2), cup impingement (n=1), primary posttraumatic arthroplasty (n=8), and acetabular dysplasia (n=4). The jumbo cups used were COPTOS TH (SERF), which combines press-fit fixation with supplemental fixation (acetabular hook, two superior flanges with one to four screws, two acetabular pegs). A bone graft was added in 74 cases (80%). The clinical assessment consisted of the Harris hip score. The primary endpoint was surgical revision for aseptic acetabular loosening or the occurrence of a dislocation episode. In all, 93 patients were reviewed at a mean follow-up of 5.3 ± 2.3 years [0, 10]. As of the last follow-up, the acetabular cup had been changed in five cases: three due to aseptic loosening (3.2%) and two due to infection (2.1%). The survivorship free of aseptic loosening was 96.8%. Three patients (3%) suffered a dislocation. At the last follow-up visit, the mean HSS scores were 72.15, (p < 0.05). Use of a jumbo DM cup in cases of acetabular bone defects leads to satisfactory medium-term results with low dislocation and loosening rates.
BACKGROUND. During revision hip arthroplasty, removal of a well-fixed, ingrown metal acetabular component may not be possible. Therefore, a new polyethylene liner can be cemented into the existing shell via the cement locking mechanism. We report the indications, technique, and results of cementing an acetabular liner into a well-fixed cementless acetabular shell. PATIENTS AND METHODS. All patients were given informed consent to participate in this study, and the study was approved by our hospital institutional review board. Of 95
Revision of fractured ceramic-on-ceramic total hip replacements with a cobalt-chromium (CoCr) alloy-on-polyethylene articulation can facilitate metallosis and require further expensive revision surgery [1–3]. In the present study, a fifty-two year old male patient suffered from fatal cardiomyopathy after undergoing
Introduction. The goal of
Introduction. Previous studies of ceramic-on-polyethylene (C-PE) and ceramic-on-ceramic (COC) hip bearings have focused on outcomes following primary surgery. Less is known about the utilization or outcomes of ceramic bearings in
Introduction. The mid- or long-term results of acetabular
Introduction. Failure of acetabular components has been reported to lead to large bone defects, which determine outcome and management after
Background. Total joint replacement surgery is associated with large amounts of blood loss and significant rates of transfusions. Postoperative bleeding is one of the most important problems after major orthopedic surgeries including