Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

ACETABULAR RECONSTRUCTION OF EXTENSIVE BONE DEFECT WITH REINFORCE DEVICE IN REVISION TOTAL HIP ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 2.



Abstract

Acetabular reconstruction of extensive bone defect is troublesome in revision total hip arthroplasty (rTHA). Kerboull or Kerboull type reinforcement acetabular device with allobone grafting has been applied since 1996. Clinical results of the procedure were evaluated.

Patients

One hundred and ninety-two consecutive revision total hip arthroplasties were performed with allograft bone supported by the Kerboull or Kerboull type reinforcement acetabular device from 1996 to 2009. There were 23 men and 169 women. Kerboull plates were applied to 18 patients, and Kerboull type plates to 174. The mean follow up of the whole series was 8 years (4–18years).

Surgical Technique

The superior bone defect was reconstructed principally by a large bulky allo block with plate system. Medial bone defect was reconstructed by adequate bone chips and/or sliced bone plates. After temporally fixation of bulky bone block with two 2.0mm K-wires, it was remodeled by reaming to fit the gap between host bone and plate, followed by fixation to the iliac bone by screws. Finally, residual space of the defect between host bone and the fixed plated was filled up with morselized cancellous bones, bone chips, and/or wedged bony fragments with impaction. This method was sufficiently applicable to AAOS Typeâ�, II, and III bone defects. In case of AAOS Typeâ�£, the procedure was also available after repairing discontinuation between distal and proximal bones by reconstrusion plate or allografting with tibial bone plates or sliced femoral head.

Results

Nine patients (4.7%) required revision surgery (infection 5, breakage 3, and malalignment 1). The plate breakage was observed in 8 joints (4.2%). Three patients had no symptoms after the breakage. Three required revision, but the other cases were carefully observed without additional surgical intervention. Ten-year survival rate by Kaplan-Meier method was 96.6% when the endpoint was set revision by asceptic loosning.

Conclusions

This study indicated that acetabular allograft reconstructions reinforced by Kerboull or Kerboull type acetabular device were able to recover bone stock with anatomic reconstruction of femoral head center, thus providing satisfactory clinical results in middle term period.


Email: