Advertisement for orthosearch.org.uk
Results 1 - 20 of 195
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 56 - 56
1 Mar 2021
Moore AJ Palmer C Mallon C Gooberman-Hill R Whitehouse MR Blom AW
Full Access

Prosthetic joint infection (PJI) is an uncommon but serious complication of hip replacement. Over 1,000 operations are performed annually in the United Kingdom for PJI following hip replacement, using either one- or two-stage revision arthroplasty. It is unclear which is preferred by patients and which has the best long-term outcome. This qualitative study aims to describe patient experiences of treatment and recovery following one- and two-stage revision arthroplasty for PJI within the context of a pragmatic randomised controlled trial comparing these two approaches. Semi-structured interviews were conducted with 32 patients undergoing one- or two-stage revision treatment for PJI as part of a UK multi-centre randomised controlled trial. Patients were recruited from 12 participating National Health Service (NHS) Orthopaedic Departments and were interviewed 2–4 months after their first revision surgery and again approximately 18 months later. Final sample size was justified on the basis of thematic saturation. All patients consented to the interview being audio-recorded, transcribed, anonymised and analysed using an inductive thematic approach. Ethical approval was provided by NRES Committee South-West Frenchay, 14/SW/116. Patients in both the one- and two-stage treatment groups described prolonged hospital stays, with burdensome antibiotics and brief physiotherapy treatment. However, following discharge home and during recovery, participants undergoing two-stage revision with an ‘empty hip' or with a spacer reported being physically restricted in almost every aspect of their daily life, resulting in inactivity and confinement to home. Mobility aids were not sufficiently available through the health service for these patients. A key difference is that those with a spacer reported more pain than those without. Approximately one year following their second-stage revision, participants described being more independent and active, but two directly attributed muscle weakness to the lengthy period without a hip and described resulting falls or dislocations that had complicated their recovery. In contrast, those undergoing one-stage revision and CUMARS appeared to be more alike, reporting better mobility, functionality and independence, although still limited. Participants in these groups also reported minimal or no pain following their revision. A key difference between CUMARS and one-stage revision was the uncertainty of whether a second operation was necessary, which participants described as “hanging over them”, while those in the two-stage empty hip or spacer group described a more positive anticipation of a second definitive operation as it marked an end to what was described as a detachment from life. Our findings highlight the differences between patient experiences of recovery following revision arthroplasty, and how this is influenced by the surgical approach and presence or lack of spacers. An understanding of lived experiences following one- and two-stage surgical interventions will complement knowledge about the clinical effectiveness of these different types of revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 87 - 87
1 Mar 2021
Bommireddy L Crimmins A Gogna R Clark DI
Full Access

Abstract. Objectives. Operative management of distal humerus fractures is challenging. In the past, plates were manually contoured intraoperatively, however this was associated with high rates of fixation failure, nonunion and metalwork removal. Anatomically pre-contoured distal humerus locking plates have since been developed. Owing to the rarity of distal humeral fractures, literature regarding outcomes of anatomically pre-contoured locking plates is lacking and patient numbers are often small. The purpose of this study is to investigate the outcomes of these patients. Methods. We retrospectively identified patients with distal humeral fractures treated at our institution from 2009–2018. Inclusion criteria were patients with a distal humeral fracture, who underwent two-column plate fixation with anatomically pre-contoured locking plates. Clinical records and radiographs were reviewed to elicit outcome measures, including range of motion, complications and reoperation rate. Results. We identified 50 patients with mean age of 55 years (range 17–96 years). Mean length of follow up was 5.2 years. AO fracture classification Type A occurred most frequently (46%), followed by Type B (22%) and Type C (32%). Low energy mechanisms of injury predominated in 72% of patients. Mean time from injury to fixation was seven days. Mean range of motion at the elbow was 13–123o postoperatively. The overall reoperation rate was 22%, the majority of which required subsequent removal of prominent metalwork (18%). The incidence of nonunion, heterotopic ossification, deep infection and neuropathy requiring decompression was 2% each. Fixation failure occurred in only one patient however the fracture went on to heal. Conclusions. Previously reported reoperation rates with manually contoured plates were as high as 44%, which is twice our reported rate. Modern locking plates are no longer subject to implant failure (previously 27% reported metalwork failure rate). Likewise, heterotopic ossification and non-union have also reduced, highlighting that modern plates have significantly improved overall patient outcomes. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 18 - 18
1 Nov 2021
Troiano E Facchini A Meglio MD Peri G Aiuto P Mondanelli N Giannotti S
Full Access

Introduction and Objective. In recent years, along with the extending longevity of patients and the increase in their functional demands, the number of annually performed RSA and the incidence of complications are also increasing. When a complication occurs, the patient often needs multiple surgeries to restore the function of the upper limb. Revision implants are directly responsible for the critical reduction of the bone stock, especially in the shoulder. The purpose of this paper is to report the use of allograft bone to restore the bone stock of the glenoid in the treatment of an aseptic glenoid component loosening after a reverse shoulder arthroplasty (RSA). Materials and Methods. An 86-years-old man came to our attention for aseptic glenoid component loosening after RSA. Plain radiographs showed a complete dislocation of the glenoid component with 2 broken screws in the neck of glenoid. CT scans confirmed the severe reduction of the glenoid bone stock and critical bone resorption and were used for the preoperative planning. To our opinion, given the critical bone defect, the only viable option was revision surgery with restoration of bone stock. We planned to use a bone graft harvested from distal bone bank femur as component augmentation. During the revision procedure the baseplate with a long central peg was implanted “on table” on the allograft and an appropriate osteotomy was made to customize the allograft on the glenoid defect according to the CT-based preoperative planning. The Bio-component was implanted with stable screws fixation on residual scapula. We decided not to replace the humeral component since it was stable and showed no signs of mobilization. Results. The new bio-implant was stable, and the patient gained a complete functional recovery of the shoulder. The scheduled radiological assessments up to 12 months showed no signs of bone resorption or mobilization of the glenoid component. Conclusions. The use of bone allograft in revision surgery after a RSA is a versatile and effective technique to treat severe glenoid bone loss and to improve the global stability of the implant. Furthermore, it represents a viable alternative to autologous graft since it requires shorter operative times and reduces graft site complications. There are very few data available regarding the use of allografts and, although the first studies are encouraging, further investigation is needed to determine the biological capabilities of the transplant and its validity in complex revisions after RSA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 41 - 41
1 Aug 2013
Kazi Z Mackie AJ Shah K
Full Access

Cheilectomy of the big toe is offered in the early stages of arthritis affecting the big toe MTPJ, with the understanding that if it fails then a more definitive surgical treatment (e.g. MTPJ fusion or replacement) may be required. When considering treatment options, patients want to know how long will a cheilectomy procedure last. There is limited evidence available about the long term results after cheliectomy, particularly with regards to time to revision surgery. Our aim was to establish the long-term results of cheilectomy with regards to revision surgery and patient-satisfaction over a period of 10 years. A retrospective review of big toe MTPJ cheilectomies was performed at our institute from 2002 to 2012. The patients were identified using a combination of medical coding system, clinical records, operative log, and radiographs. A systemic review of chielectomy by Roukis (2010) was identified as the clinical standard and revision surgery after cheilectomy, average time to revision and patient satisfaction was assessed. 204 cheilectomies were identified in 192 patients over a period of 10 years. Majority had grade 2 OA (n = 106, 54 %) with grade 3 (n= 65, 33 %) and grade 1 (n= 24, 12 %). The mean follow-up was 4 yrs. (range 6 m to 9 yrs. and 8 m). The overall revision rate to any surgery was 4.4% (n=9), and revision to MTPJ arthrodesis was 3.4% (n =7). The average time to revision was 1 yr. 4 m. 101 patients (55%) were contactable over the phone, and majority (82 %) of them were satisfied with the clinical outcome. This study shows slightly better overall revision rate (4.4% vs. 8.8%), with revision to arthrodesis being similar (3.4% vs. 3.25%) as compared to the clinical standard. It also suggests that cheilectomy of the big toe can last for a minimum of up to 4 years in 95 % of cases. The 5 % of cases that may require revision surgery are likely to present within the first 2 years. This information is very useful to a patient who wants to know “how long will my cheilectomy last?” whilst making an informed choice


Introduction and Objective. Posterior and transforaminal lumbar interbody fusion (PLIF, TLIF) represent the most popular techniques in performing an interbody fusion amongst spine surgeons. Pseudarthrosis, cage migration, subsidence or infection can occur, with subsequent failed surgery, persistent pain and patient’ bad quality of life. The goal of revision fusion surgery is to correct any previous technical errors avoiding surgical complications. The most safe and effective way is to choose a naive approach to the disc. Therefore, the anterior approach represents a suitable technique as a salvage operation. The aim of this study is to underline the technical advantages of the anterior retroperitoneal approach as a salvage procedure in failed PLIF/TLIF analyzing a series of 32 consecutive patients. Materials and Methods. We performed a retrospective analysis of patients’ data in patients who underwent ALIF as a salvage procedure after failed PLIF/TLIF between April 2014 to December 2019. We recorded all peri-operative data. In all patients the index level was exposed with a minimally invasive anterior retroperitoneal approach. Results. Thirty-two patients (average age: 46.4 years, median age 46.5, ranging from 21 to 74 years hold- 16 male and 16 female) underwent salvage ALIF procedure after failed PLIF/TLIF were included in the study. A minimally invasive anterior retroperitoneal approach to the lumbar spine was performed in all patients. In 6 cases (18.7%) (2 infection and 4 pseudarthrosis after stand-alone IF) only anterior revision surgery was performed. A posterior approach was necessary in 26 cases (81.3%). In most of cases (26/32, 81%) the posterior instrumentation was overpowered by the anterior cage without a previous revision. Three (9%) intraoperative minor complications after anterior approach were recorded: 1 dural tear, 1 ALIF cage subsidence and 1 small peritoneal tear. None vascular injuries occurred. Most of patients (90.6%) experienced an improvement of their clinical condition and at the last follow-up no mechanical complication occurred. Conclusions. According to our results, we can suggest that a favourable clinical outcome can firstly depend from technical reasons an then from radiological results. The removal of the mobilized cage, the accurate endplate and disc space preparation and the cage implant eliminate the primary source of pain reducing significantly the axial pain, helping to realise an optimal bony surface for fusion and enhancing primary stability. The powerful disc distraction given by the anterior approach allows inserting large and lordotic cages improving the optimal segmental lordosis restoration


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 267 - 271
1 Feb 2005
van Haaren EH Smit TH Phipps K Wuisman PIJM Blunn G Heyligers IC

Impacted morsellised allografts have been used successfully to address the problem of poor bone stock in revision surgery. However, there are concerns about the transmission of pathogens, the high cost and the shortage of supply of donor bone. Bone-graft extenders, such as tricalcium phosphate (TCP) and hydroxyapatite (HA), have been developed to minimise the use of donor bone. In a human cadaver model we have evaluated the surgical and mechanical feasibility of a TCP/HA bone-graft extender during impaction grafting revision surgery. A TCP/HA allograft mix increased the risk of producing a fissure in the femur during the impaction procedure, but provided a higher initial mechanical stability when compared with bone graft alone. The implications of the use of this type of graft extender in impaction grafting revision surgery are discussed


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 94 - 94
1 Jan 2017
Moore A Heddington J Whitehouse M Peters T Gooberman-Hill R Beswick A Blom A
Full Access

Around 1% of the 185,000 primary hip and knee arthroplasties performed in the UK are followed by prosthetic joint infection (PJI). Although PJI affects a small percentage of patients, it is one of the most devastating complications associated with this procedure. Treatment usually involves further major surgery which can adversely affect patients' quality of life. Understanding current service provision provides valuable information needed to design and evaluate support interventions for patients. The aim of this survey was to identify usual care pathways and support in UK NHS orthopaedic centres for this population. The 20 highestvolume UK NHS orthopaedic centresfor hip and knee arthroplasty account for 33–50% of all cases treated for prosthetic joint infection. Infection leads at each centre were invited to participate in a survey about usual care provision and support for PJI. Questions exploredfollow up time-points; use of standard outcome measures; multidisciplinary care plans; supportive in-patient care and care after treatment; and onward referrals. Survey responses were recorded on a standardised proforma. Data were entered into Excel for analysis, then reviewed and coded into categories and frequency statistics to describe categorical data. A descriptive summary was developed based on these categories. Eleven of the highestvolume orthopaedic centres completed the survey. Follow-up of patients varied greatly across centres; some centres reviewed patients at weekly or 2 week intervals, while all centres saw patients at 6 weeks. Long-term follow-up varied across centres from 3–4 monthsto 12 monthly. Length of follow-up period varied from until the infection had cleared toindefinitely. Follow-up timepoints were only standardised in 4 out of 11 centres. Only 1 centre had a dedicated infection clinic. Advice on who patients should contact if they had concerns included the consultant, community nurse, extended scope practitioner or the ward, while 3 centres told patients to avoid calling their GP. Only half of the centres routinely used standardised outcome measures with patients with PJI. The majority of centres provided standard physiotherapy and occupational therapy (OT) to in-patients while approximately half also offered social support. Only one centre provided dedicated physiotherapy and OT on a separate infection ward. Three centres provided hospital at home or community services to patients in-between operative stages. Only 3 out of 11 centres stated they had specific multidisciplinary care plans in place for patients. Once discharged most patients were provided with physiotherapy, OT and social services if needed. Common barriersto referral included complexities of referring patients outside the hospital catchment area;lack of availability of community services, and shortage of staff including physiotherapists. Delays in rehab and social services could also be problematic. Findings show wide variation intreatment pathways and support for patients treated for PJI, both as inpatients and in the community. Only one of the 11 centreswho participated had a dedicated infection clinic. Only one centre suggested they individualised their physiotherapy support. A number of barriers exist to referring patients on to other support services after revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 69 - 69
1 Mar 2021
Ghani R Usman M Salar O Khan A Karim J Davis E Quraishi S Ahmed M
Full Access

Abstract

Objectives

Up to 19% of patients who undergo surgery for an acute hip fracture are readmitted to the hospital within three months of the index operation. We aimed to identify risk factors for unplanned clinic attendance, readmission, and mortality within the first 12 months postoperatively and subsequently determine if there is a role for routine follow-up.

Methods

Patients greater than 65 years old who underwent hip hemiarthroplasty using an uncemented Thompson implant for treatment of a traumatic non-pathological hip fracture were identified from a prospectively maintained database at a single institution between August 2007 and February 2011. Patient demographics, comorbidities, place of residence, mobility status, unplanned attendance to an orthopaedic clinic with symptoms relating to the respective limb, readmission, and mortality were recorded.


Results in patients undergoing total hip arthroplasty (THA) for femoral head osteonecrosis (ON) when compared with primary osteoarthritis (OA) are controversial. Different factors like age, THA type or surgical technique may affect outcome. We hypothesized that patients with ON had an increased revision rate compared with OA. We analysed clinical outcome, estimated the survival rate for revision surgery, and their possible risk factors, in two groups of patients. In this retrospective cohort analysis of our prospective database, we assessed 2464 primary THAs implanted between 1989 and 2017. Patients with OA were included in group 1, 2090 hips; and patients with ON in group 2, 374 hips. In group 2 there were more men (p<0.001), patients younger than 60 years old (p<0.001) and with greater physical activity (p<0.001). Patients with lumbar OA (p<0.001) and a radiological acetabular shape type B according to Dorr (p<0.001) were more frequent in group 1. Clinical outcome was assessed according to the Harris Hip Score and radiological analysis included postoperative acetabular and femoral component position and hip reconstruction. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having revision surgery for different reasons. Univariate and multivariate Cox regression models were used to assess risk factors for revision surgery. Clinical improvement was better in the ON at all intervals. There were 90 hips revised, 68 due to loosening or wear, 52 (2.5%) in group 1, and 16 (4.3%) in group 2. Overall, the survival rate for revision surgery for any cause at 22 years was 88.0 % (95% CI, 82-94) in group 1 and 84.1% (95% CI, 69 – 99) in group 2 (p=0.019). Multivariate regression analysis showed that hips with conventional polyethylene (PE), compared with highly-cross linked PEs or ceramic-on-ceramic bearings, (p=0.01, Hazard Ratio (HR): 2.12, 95% CI 1.15-3.92), and cups outside the Lewinnek´s safe zone had a higher risk for revision surgery (p<0.001, HR: 2.57, 95% CI 1.69-3.91). Modern highly-cross linked PEs and ceramic-on-ceramic bearings use, and a proper surgical technique improved revision rate in patients undergoing THA due to ON compared with OA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 35 - 35
1 Dec 2022
Montanari S Griffoni C Cristofolini L Brodano GB
Full Access

Mechanical failure of spine posterior fixation in the lumbar region Is suspected to occur more frequently when the sagittal balance is not properly restored. While failures at the proximal extremity have been studied in the literature, the lumbar distal junctional pathology has received less attention. The aim of this work was to investigate if the spinopelvic parameters, which characterize the sagittal balance, could predict the mechanical failure of the posterior fixation in the distal lumbar region. All the spine surgeries performed in 2017-2019 at Rizzoli Institute were retrospectively analysed to extract all cases of lumbar distal junctional pathology. All the revision surgeries performed due to the pedicle screws pull-out, or the breakage of rods or screws, or the vertebral fracture, or the degenerative disc disease, in the distal extremity, were included in the junctional (JUNCT) group. A total of 83 cases were identified as JUNCT group. All the 241 fixation surgeries which to date have not failed were included in the control (CONTROL) group. Clinical data were extracted from both groups, and the main spinopelvic parameters were assessed from sagittal standing preoperative (pre-op) and postoperative (post-op) radiographs with the software Surgimap (Nemaris). In particular, pelvic incidence (PI), sagittal vertical axis (SVA), pelvic tilt (PT), T1 pelvic angle (TPA), sacral slope (SS) and lumbar lordosis (LL) have been measured. In JUNCT, the main failure cause was the screws pull-out (45%). Spine fixation with 7 or more levels were the most common in JUNCT (52%) in contrast to CONTROL (14%). In CONTROL, PT, TPA, SS and PI-LL were inside the recommended ranges of good sagittal balance. For these parameters, statistically significant differences were observed between pre-op and post-op (p<0.0001, p=0.01, p<0.0001, p=0.004, respectively, Wilcoxon test). In JUNCT, the spinopelvic parameters were out of the ranges of the good sagittal balance and the worsening of the balance was confirmed by the increase in PT, TPA, SVA, PI-LL and by the decrease of LL (p=0.002, p=0.003, p<0.0001, p=0.001, p=0.001, respectively, paired t-test) before the revision surgery. TPA (p=0.003, Kolmogorov-Smirnov test) and SS (p=0.03, unpaired t-test) differed significantly in pre-op between JUNCT and CONTROL. In post-op, PI-LL was significantly different between JUNCT and CONTROL (p=0.04, unpaired t-test). The regression model of PT vs PI was significantly different between JUNCT and CONTROL in pre-op (p=0.01, Z-test). These results showed that failure is most common in long fused segments, likely due to long lever arms leading to implant failure. If the sagittal balance is not properly restored, after the surgery the balance is expected to worsen, eventually leading to failure: this effect was confirmed by the worsening of all the spinopelvic parameters before the revision surgery in JUNCT. Conversely, a good sagittal balance seems to avoid a revision surgery, as it is visible is CONTROL. The mismatch PI-LL after the fixation seems to confirm a good sagittal balance and predict a good correction. The linear regression of PT vs PI suggests that the spine deformity and pelvic conformation could be a predictor for the failure after a fixation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails. A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4. Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes. The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 88 - 88
4 Apr 2023
Anjum S Kirby J Deehan D Tyson-Capper A
Full Access

The most common reason for revision surgery of total hip replacements is aseptic loosening of implants secondary to osteolysis, which is caused by immune-mediated reactions to implant debris. These debris can cause pseudotumour formation. As revision surgery is associated with higher mortality and infection, it is important to understand the pro-inflammatory process to improve implant survival. Toll-like receptor 4 (TLR4) has been shown to mediate immune responses to cobalt ions. Statin use in epidemiological studies has been associated with reduced risk of revision surgery. In-vitro studies have demonstrated the potential for statins to reduce orthopaedic debris-induced immune responses and there is evidence that statins can modulate TLR4 activity. This study investigates simvastatin's effect on orthopaedic biomaterial-mediated changes in protein expression of key inflammatory markers and soluble-ICAM-1 (sICAM-1), an angiogenic factor implicated in pseudotumour formation. Human macrophage THP-1 cells were pre-incubated with 50µM simvastatin for 2-hours or a vehicle control (VC), before being exposed to 0.75mM cobalt chloride, 50μm3 per cell zirconium oxide or LPS as a positive control, in addition to a further 24-hour co-incubation with 50µM simvastatin or VC. Interleukin −8 (IL-8), sICAM-1, chemokine ligand 2 (CCL2), CCL3 and CCL4 protein secretion was measured by enzyme-linked immunosorbent assay (ELISA). GraphPad Prism 10 was used for statistical analysis including a one-way ANOVA. Pre-treatment with simvastatin significantly reduced LPS and cobalt-mediated IL-8 secretion (n=3) and sICAM-1 protein secretion (n=2) in THP-1 cells. Pre-treatment with simvastatin significantly reduced LPS-mediated but not cobalt ion-mediated CCL2 (n=3) and CCL3 protein (n=3) secretion in THP-1 cells. Simvastatin significantly reduced zirconium oxide-mediated CCL4 secretion (n=3). Simvastatin significantly reduced cobalt-ion mediated IL-8 and sICAM-1 protein secretion in THP-1 cells. This in-vitro finding demonstrates the potential for simvastatin to reduce recruitment of leukocytes which mediate the deleterious inflammatory processes driving implant failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 95 - 95
4 Apr 2023
Troiano E Giacomo P Di Meglio M Nuvoli N Mondanelli N Giannotti S Orlandi N
Full Access

Infections represent a devastating complication in orthopedic and traumatological surgery, with high rates of morbidity and mortality. An early intervention is essential, and it includes a radical surgical approach supported by targeted intravenous antimicrobial therapy. The availability of parenteral antibiotics at the site of infection is usually poor, so it is crucial to maximize local antibiotic concentration using local carriers. Our work aims to describe the uses of one of these systems, Stimulan®, for the management and prevention of infections at our Institution. Analysing the reported uses of Stimulan®, we identified two major groups: bone substitute and carrier material for local antibiotic therapy. The first group includes its application as a filler of dead spaces within bone or soft tissues resulting from traumatic events or previous surgery. The second group comprehends the use of Stimulan® for the treatment of osteomyelitis, post-traumatic septic events, periprosthetic joint infections, arthroplasty revision surgery, prevention in open fractures, surgery of the diabetic foot, oncological surgery and for all those patients susceptible to a high risk of infection. We used Stimulan® in several complex clinical situations: in PJIs, in DAPRI procedure and both during the first and the second stage of a 2-stage revision surgery; furthermore, we started to exploit this antibiotic carrier also in prophylaxis of surgical site infections, as it happens in open fractures, and when a surgical site remediation is required, like in osteomyelitis following ORIF. Stimulan® is an extremely versatile and polyhedric material, available in the form of beads or paste, and can be mixed to a very broad range of antibiotics to better adapt to different bacteria and their antibiograms, and to surgeon's needs. These properties make it a very useful adjuvant for the management of complex cases of infection, and for their prevention, as well


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 132 - 132
4 Apr 2023
Callary S Abrahams J Zeng Y Clothier R Costi K Campbell D Howie D Solomon L
Full Access

First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone. Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging. Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9-71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%). The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor bone quality. Components without press-fit or three-point fixation were associated with unacceptable amounts of early migration


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 29 - 29
17 Nov 2023
Morris T Dixon J Baldock T Eardley W
Full Access

Abstract. Objectives. The outcomes from patella fracture have remained dissatisfactory despite advances in treatment, especially from operative fixation1. Frequently, reoperation is required following open reduction and internal fixation (ORIF) of the patella due to prominent hardware since the standard technique for patella ORIF is tension band wiring (TBW) which inevitably leaves a bulky knot and irritates soft tissue given the patella's superficial position2. We performed a systematic review to determine the optimal treatment of patella fractures in the poor host. Methods. Three databases (EMBASE/Medline, ProQuest and PubMed) and one register (Cochrane CENTRAL) were searched. 476 records were identified and duplicates removed. 88 records progressed to abstract screening and 73 were excluded. Following review of complete references, 8 studies were deemed eligible. Results. Complication rates were shown to be high in our systematic review. Over one-fifth of patients require re-operation, predominantly for removal of symptomatic for failed hardware. Average infection rate was 11.95% which is higher than rates reported in the literature for better hosts. Nevertheless, reported mortality was low at 0.8% and thromboembolic events only occurred in 2% of patients. Average range of movement achieved following operative fixation was approximately 124 degrees. Upon further literature review, novel non-operative treatment options have shown acceptable results in low-demand patients, including abandoning weight-bearing restrictions altogether and non-operatively treating patients with fracture gaps greater than 1cm. Regarding operative management, suture/cable TBW has been investigated as a viable option with good results in recent years since the materials used show comparable biomechanics to stainless steel. Additionally, ORIF with locking plates have shown favourable results and have enabled aggressive post-operative rehabilitation protocols. TBW with metallic implants has shown higher complication rates, especially for anterior knee pain, reoperation and poor functional outcomes. Conclusion. There is sparse literature regarding patella fracture in the poor host. Nevertheless, it is clear that ORIF produces better outcomes than conservative treatment but the optimal technique for patella ORIF remains unclear. TBW with metallic implants should not remain the standard technique for ORIF; low-profile plates of suture TBW are more attractive solutions. Non-operative treatment may be considered for low-demand individuals however any form of patellectomy should be avoided if possible. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 3 - 3
1 Dec 2022
Leardini A Caravaggi P Ortolani M Durante S Belvedere C
Full Access

Among the advanced technology developed and tested for orthopaedic surgery, the Rizzoli (IOR) has a long experience on custom-made design and implant of devices for joint and bone replacements. This follows the recent advancements in additive manufacturing, which now allows to obtain products also in metal alloy by deposition of material layer-by-layer according to a digital model. The process starts from medical image, goes through anatomical modelling, prosthesis design, prototyping, and final production in 3D printers and in case post-production. These devices have demonstrated already to be accurate enough to address properly the specific needs and conditions of the patient and of his/her physician. These guarantee also minimum removal of the tissues, partial replacements, no size related issues, minimal invasiveness, limited instrumentation. The thorough preparation of the treatment results also in a considerable shortening of the surgical and of recovery time. The necessary additional efforts and costs of custom-made implants seem to be well balanced by these advantages and savings, which shall include the lower failures and revision surgery rates. This also allows thoughtful optimization of the component-to-bone interfaces, by advanced lattice structures, with topologies mimicking the trabecular bone, possibly to promote osteointegration and to prevent infection. IOR's experience comprises all sub-disciplines and anatomical areas, here mentioned in historical order. Originally, several systems of Patient-Specific instrumentation have been exploited in total knee and total ankle replacements. A few massive osteoarticular reconstructions in the shank and foot for severe bone fractures were performed, starting from mirroring the contralateral area. Something very similar was performed also for pelvic surgery in the Oncology department, where massive skeletal reconstructions for bone tumours are necessary. To this aim, in addition to the standard anatomical modelling, prosthesis design, technical/technological refinements, and manufacturing, surgical guides for the correct execution of the osteotomies are also designed and 3D printed. Another original experience is about en-block replacement of vertebral bodies for severe bone loss, in particular for tumours. In this project, technological and biological aspects have also been addressed, to enhance osteointegration and to diminish the risk of infection. In our series there is also a case of successful custom reconstruction of the anterior chest wall. Initial experiences are in progress also for shoulder and elbow surgery, in particular for pre-op planning and surgical guide design in complex re-alignment osteotomies for severe bone deformities. Also in complex flat-foot deformities, in preparation of surgical corrections, 3D digital reconstruction and 3D printing in cheap ABS filaments have been valuable, for indication, planning of surgery and patient communication; with special materials mimicking bone strength, these 3D physical models are precious also for training and preparation of the surgery. In Paediatric surgery severe multi planar & multifocal deformities in children are addressed with personalized pre-op planning and custom cutting-guides for the necessary osteotomies, most of which require custom allografts. A number of complex hip revision surgeries have been performed, where 3D reconstruction for possible final solutions with exact implants on the remaining bone were developed. Elective surgery has been addressed as well, in particular the customization of an original total ankle replacement designed at IOR. Also a novel system with a high-tibial-osteotomy, including a custom cutting jig and the fixation plate was tested. An initial experience for the design and test of custom ankle & foot orthotics is also in progress, starting with 3D surface scanning of the shank and foot including the plantar aspect. Clearly, for achieving these results, multi-disciplinary teams have been formed, including physicians, radiologists, bioengineers and technologists, working together for the same goal


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2021
Hara M Yamazaki K
Full Access

Introduction and Objective. Nonunion is incomplete healing of fracture and fracture that lacks potential to heal without further intervention. Nonunion commonly presents with persistent pain, swelling, or instability. Those symptoms affect patient quality of life. It is known that using low intensity pulsed ultrasound (LIPUS) for fresh fractures promotes healing. However, effectiveness of LIPUS for nonunion is still controversial. If LIPUS is prove to be effective for healing nonunion, it can potentially provide an alternative to surgery. In addition, we can reduce costs by treating nonunion with LIPUS than performing revision surgery. Materials and Methods. The two authors carried out a systematic search of PubMed, Ovid MEDLINE, and the Cochrane Library. Meta-analysis of healing rate in nonunion and delayed union patients who underwent LIPUS was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) instruction method using a random effects model. Results. The initial search identified 652 articles. Of these, 541 were excluded on the basis of the title because they were either a review paper or covered an unrelated topic. The abstracts of the remaining 111 articles were examined further. That review resulted in a sample of 12 articles. We performed a meta-analysis with a random effects model using Open Meta Analyst software. The result of pooled effect size of healing rate was 73.4% (95%CI: 65.3–81.6%). Due to the fact that nonunion lacks potential to heal without further intervention, we suggest that the therapeutic effect of 73.4% from LIPUS is sufficiently effective. As far as we know, there are no trials comparing the therapeutic effectiveness of surgery and LIPUS, so it cannot be said which is more advantageous. However, the healing rate of revision surgery was reported between 68–96%; therefore, our result is within that range. Thus, if surgery is difficult due to complications, we can recommend LIPUS. Conclusions. Meta-analysis of healing rate of nonunion treated by low-intensity pulsed ultrasound is 73.4%, which suggests sufficient therapeutic effectiveness. Furthermore, we can say that LIPUS may provide an alternative treatment for nonunion patients who cannot tolerate revision surgery due to complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 94 - 94
1 Mar 2021
Gallo J Kudelka M Radvansky M Kriegova E
Full Access

Precision medicine tailoring the patient pathway based on the risk, prognosis, and treatment response may bring benefits to the patients. To identify risk factors contributing to the early failure of treatment (development of events of interest) and when possible to change the prognosis via modifying these factors may improve the outcome and/or lower the risk of complications. There is an emerging goal to identify such parameters in total knee arthroplasty (TKA) thus lower the risk of revision surgery. The goal of this study was to identify factors explaining the risk for early revision of TKA using an artificial intelligence method appropriate for this task. We applied a patient similarity network (PSN) for the identification of risk factors associated with early reoperations (n=109, 5.8%) in patients with TKA (n=1885). Next, an algorithm based on formal concept analysis was developed to support the patient decision on how to change modifying personal characteristics with respect to the estimated probability of reoperations. The early reoperations were less frequent in women (4.4%, median time to reoperation 4.5 mo) than in men (8.2%, 10 mo), reaching the highest incidence in younger men (10.9%)


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 115 - 115
11 Apr 2023
Tay M Carter M Bolam S Zeng N Young S
Full Access

Unicompartmental knee arthroplasty (UKA) has a higher risk of revision than total knee arthroplasty, particularly for low volume surgeons. The recent introduction of robotic-arm assisted systems has allowed for increased accuracy, however new systems typically have learning curves. The objective of this study was to determine the learning curve of a robotic-arm assisted system for UKA. Methods A total of 152 consecutive robotic-arm assisted primary medial UKA were performed by five surgeons between 2017 and 2021. Operative times, implant positioning, reoperations and patient-reported outcome measures (PROMS; Oxford Knee Score, EuroQol-5D, and Forgotten Joint Score) were recorded. There was a learning curve of 11 cases with the system that was associated with increased operative time (13 minutes, p<0.01) and improved insert sizing over time (p=0.03). There was no difference in implant survival (98.2%) between learning and proficiency phases (p = 0.15), and no difference in survivorship between ‘high’ and ‘low’ usage surgeons (p = 0.23) at 36 months. There were no differences in PROMS related to the learning curve. This suggested that the learning curve did not lead to early adverse effects in this patient cohort. The introduction of a robotic-arm assisted UKA system led to learning curves for operative time and implant sizing, but there was no effect on patient outcomes at early follow- up. The short learning curve was independent of UKA usage and indicated that robotic-arm assisted UKA may be particularly useful for low-usage surgeons