Advertisement for orthosearch.org.uk
Results 1 - 20 of 46
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 113 - 113
1 Sep 2012
Dietz S Schwarz T Sternstein W Rommens P
Full Access

Open reduction and internal fixation of proximal humerus fractures with angular stable plates is, beside antegrade nailing of the humerus, a standard procedure. A retrograde nail has been developed to avoid penetrating the rotator cuff and to avoid opening the fracture side during osteosynthesis. The aim of our biomechanical study was to evaluate if retrograde nailing of proximal humerus fractures is as stable as locking plate osteosynthesis. The biomechanical properties of 2 implants were tested in 11 human fresh frozen cadaveric humeri pairs. The Retron Nail® and the Philos® plate were implanted after osteotomy. All specimens were suspected to axial and torque load for 1000 cycles in a servo pneumatic testing apparatus. The Philos® plate had greater torsion stiffness than the Retron® nail, but we found no significance. The Retron® nail had greater axial stiffness but our findings were not statistically significant. Our study showed, that there are no significant differences between a retrograde nail and locking plate osteosynthesis for proximal humerus fractures concerning axial and torsion deformities. Therefore the retrograde nail is a suitable alternative for fixation of proximal humerus fracture


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 5 | Pages 652 - 654
1 Jul 2000
Tornetta P Tiburzi D

Retrograde femoral nailing is gaining in popularity. We report a prospective, randomised comparison of antegrade and retrograde procedures in 68 patients with 69 fractures of the femoral shaft. All nails were inserted after appropriate reaming. There was no difference in operating time, blood loss, technical complications, size of nail or reamer, or transfusion requirements. There were more problems of length and rotation using a retrograde technique on a radiolucent table than with an antegrade approach on a fracture table. All fractures in both groups healed and there was no difference in the time taken to achieve union. Although retrograde nailing is a promising technique the skills required need practice. A longer period of follow-up is necessary to determine whether there are long-term problems in the knee after such surgery


The Bone & Joint Journal
Vol. 96-B, Issue 1 | Pages 114 - 121
1 Jan 2014
Pekmezci M McDonald E Buckley J Kandemir U

We investigated a new intramedullary locking nail that allows the distal interlocking screws to be locked to the nail. We compared fixation using this new implant with fixation using either a conventional nail or a locking plate in a laboratory simulation of an osteoporotic fracture of the distal femur. A total of 15 human cadaver femora were used to simulate an AO 33-A3 fracture pattern. Paired specimens compared fixation using either a locking or non-locking retrograde nail, and using either a locking retrograde nail or a locking plate. The constructs underwent cyclical loading to simulate single-leg stance up to 125 000 cycles. Axial and torsional stiffness and displacement, cycles to failure and modes of failure were recorded for each specimen. When compared with locking plate constructs, locking nail constructs had significantly longer mean fatigue life (75 800 cycles (. sd. 33 900) vs 12 800 cycles (. sd. 6100); p = 0.007) and mean axial stiffness (220 N/mm (. sd. 80) vs 70 N/mm (. sd. 18); p = 0.005), but lower mean torsional stiffness (2.5 Nm/° (. sd. 0.9) vs 5.1 Nm/° (. sd. 1.5); p = 0.008). In addition, in the nail group the mode of failure was either cut-out of the distal screws or breakage of nails, and in the locking plate group breakage of the plate was always the mode of failure. Locking nail constructs had significantly longer mean fatigue life than non-locking nail constructs (78 900 cycles (. sd. 25 600) vs 52 400 cycles (. sd. 22 500); p = 0.04). The new locking retrograde femoral nail showed better stiffness and fatigue life than locking plates, and superior fatigue life to non-locking nails, which may be advantageous in elderly patients. Cite this article: Bone Joint J 2014;96-B:114–21


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_25 | Pages 10 - 10
1 May 2013
Higgs Z Hooper G Kumar C
Full Access

Tibiotalocalcaneal (TTC) arthrodesis using a retrograde nail is a common salvage procedure for a range of indications. Previous work has suggested subtalar joint preparation is unnecessary to achieve satisfactory results. We examine the incidence of symptomatic subtalar nonunion following tibiotalocalcaneal fusion in a series of patients, all of whom had full preparation of the subtalar joint, and consider the possible contributing factors. We performed a retrospective review of all patients who underwent TTC arthrodesis from 2004–2010. All fusions were performed by the same surgeon with full preparation of both tibiotalar and subtalar joints. 61 TTC arthrodeses were performed in 55 patients (mean age = 59 years) using an intramedullary retrograde nail. Mean follow-up was 18 months (6–48 months). Fifty-six ankles (92%) achieved satisfactory union. Five patients (8%) had symptomatic non-union: 4 patients of the subtalar joint - with 3 patients undergoing revision subtalar arthrodesis and 1 patient of the tibiotalar joint. Nine patients required removal of the calcaneal screw (16%) – all had evidence of isolated subtalar nonunion prior to metalwork failure. Eight of these patients achieved asymptomatic union following screw removal. Subtalar nonunion following TTC fusion has resulted in recent changes to nail design to increase stability across the subtalar joint. Our results demonstrate a favourable overall nonunion rate with isolated subtalar nonunion making up the majority of cases. We also observed a significant rate of distal screw loosening, also associated with subtalar nonunion prior to screw removal, the significance of which merits further investigation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 4 - 4
1 May 2018
Timms A Roskrow T Doyle H Edel P Fugazzotto S Goodier W Calder P
Full Access

Introduction. Muscle stiffness and joint contractures are common complications of limb lengthening. Authors have demonstrated less permanent soft tissue complications with intramedullary lengthening than external fixation. Our aim was to evaluate the joint response following intramedullary femoral lengthening and need for physiotherapy and alteration to rate/rhythm of lengthening. Method. A retrospective review of documentation for all femoral Precice nails in our centre inserted between 2012 and 2017. This involved 98 nails (68 antegrade, 30 retrograde) in 88 patients (59 males, 29 females) with a mean age of 32 years (range 12–69 yrs). We excluded cases where there was no documentation regarding Range of Movement (ROM). Bilateral lengthenings were recorded as separate cases. This left 50 antegrade, 16 retrograde cases with hip ROM data and 55 antegrade, 26 retrograde cases with Knee ROM data. Results. Hip. In the antegrade group 20 cases (39%) developed no stiffness throughout treatment. ROM decreased in 61% (n=30) of cases and the median length at which this occurred was 3cm. Where a retrograde nail was inserted 62.5% of cases (n=10) maintained normal range of motion. The median length at which ROM decreased was 3.25cm, this occurred in 6 cases (37.5%). . Knee. Where the antegrade nail was inserted, 22 cases (40%) did not develop stiffness. There was reduced ROM in 33 cases (60%), occurring at a median distance of 2cm. The median distance at which reduced ROM occurred with the retrograde nails was 1.5cm, this occurred in 23 cases (88.5%). 3 cases did not develop stiffness. All cases regained full ROM. Conclusion. Although there was no permanent loss, Joint Stiffness still occurs with intramedullary limb lengthening and there remains the need for regular physiotherapy. There are no data from other institutions for comparison. Rehabilitation guidelines and a proforma to accurately monitor patients ROM throughout treatment have been developed


The Bone & Joint Journal
Vol. 100-B, Issue 5 | Pages 634 - 639
1 May 2018
Davda K Heidari N Calder P Goodier D

Aims. The management of a significant bony defect following excision of a diaphyseal atrophic femoral nonunion remains a challenge. We present the outcomes using a combined technique of acute femoral shortening, stabilized with a long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis with a temporary monolateral fixator. Patients and Methods. Eight men and two women underwent the ‘rail and nail’ technique between 2008 and 2016. Proximal locking of the nail and removal of the external fixator was undertaken once the length of the femur had been restored and prior to full consolidation of the regenerate. Results. The mean lengthening was 7 cm (3 to 11). The external fixator was removed at a mean of 127 days (57 to 220). The mean bone healing index was 28 days/cm and the mean external fixation index was 20 days/cm (11 to 18). There were no superficial or deep infections. Conclusion. This small retrospective study shows encouraging results for a combined technique, enabling compression of the femoral osteotomy, alignment, and controlled lengthening. Removal of the fixator and proximal locking of the nail reduces the risk of complications and stabilizes the femur with the maximum working length of the nail. Cite this article: Bone Joint J 2018;100-B:634–9


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 449 - 454
15 Mar 2023
Zhang C Wang C Duan N Zhou D Ma T

Aims

The aim of this study was to assess the safety and clinical outcome of patients with a femoral shaft fracture and a previous complex post-traumatic femoral malunion who were treated with a clamshell osteotomy and fixation with an intramedullary nail (IMN).

Methods

The study involved a retrospective analysis of 23 patients. All had a previous, operatively managed, femoral shaft fracture with malunion due to hardware failure. They were treated with a clamshell osteotomy between May 2015 and March 2020. The mean age was 42.6 years (26 to 62) and 15 (65.2%) were male. The mean follow-up was 2.3 years (1 to 5). Details from their medical records were analyzed. Clinical outcomes were assessed using the quality of correction of the deformity, functional recovery, the healing time of the fracture, and complications.


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 387 - 393
1 Apr 2024
Dean BJF Riley N Little C Sheehan W Gidwani S Brewster M Dhiman P Costa ML

Aims

There is a lack of published evidence relating to the rate of nonunion seen in occult scaphoid fractures, diagnosed only after MRI. This study reports the rate of delayed union and nonunion in a cohort of patients with MRI-detected acute scaphoid fractures.

Methods

This multicentre cohort study at eight centres in the UK included all patients with an acute scaphoid fracture diagnosed on MRI having presented acutely following wrist trauma with normal radiographs. Data were gathered retrospectively for a minimum of 12 months at each centre. The primary outcome measures were the rate of acute surgery, delayed union, and nonunion.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 11 - 11
1 May 2018
Metikala S Madan SS Fernandes JA
Full Access

Background. Ilizarov hip reconstruction is a salvage option traditionally done with fixators, which often face limited compliance. We aimed at reviewing our early results of a novel technique with internal devices. Material and Methods. Retrospective evaluation of 7 patients was done that underwent Milch Batchelor procedure with dual plates followed by a second stage femoral lengthening by retrograde magnetic nail. The mean patient age was 13.8 years. A mean valgus of 410 (range, 300 to 550) and extension of 220 (range, 100 to 300) were created proximally. Results. At their mean recent follow-up of 19 months, all extremities were aligned with a mean Pelvic Mechanical Axis Angle (PMAA) of 83.80 and lateral Mechanical Axis Deviation (MAD) of 25.3 mm. The mean Lower-extremity Length Discrepancy (LLD) improved from 3.7 cm (range, 3 to 5 cm) preoperatively to 0.7 cm (range, 0 to 2 cm). The Trendelenburg sign was eliminated in five and delayed in 2. According to a predesigned clinical scoring system, there were 3 (43%) excellent, 2 (28.5%) good, 2 (28.5%) fair, and no poor results. One patient at 9 weeks broke plates, however went for healing. Conclusion. PSHR with internal devices is a patient-friendly alternative to fixators


Bone & Joint Open
Vol. 5, Issue 6 | Pages 452 - 456
1 Jun 2024
Kennedy JW Rooney EJ Ryan PJ Siva S Kennedy MJ Wheelwright B Young D Meek RMD

Aims

Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures.

Methods

We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 117 - 122
9 Feb 2024
Chaturvedi A Russell H Farrugia M Roger M Putti A Jenkins PJ Feltbower S

Aims

Occult (clinical) injuries represent 15% of all scaphoid fractures, posing significant challenges to the clinician. MRI has been suggested as the gold standard for diagnosis, but remains expensive, time-consuming, and is in high demand. Conventional management with immobilization and serial radiography typically results in multiple follow-up attendances to clinic, radiation exposure, and delays return to work. Suboptimal management can result in significant disability and, frequently, litigation.

Methods

We present a service evaluation report following the introduction of a quality-improvement themed, streamlined, clinical scaphoid pathway. Patients are offered a removable wrist splint with verbal and written instructions to remove it two weeks following injury, for self-assessment. The persistence of pain is the patient’s guide to ‘opt-in’ and to self-refer for a follow-up appointment with a senior emergency physician. On confirmation of ongoing signs of clinical scaphoid injury, an urgent outpatient ‘fast’-wrist protocol MRI scan is ordered, with instructions to maintain wrist immobilization. Patients with positive scan results are referred for specialist orthopaedic assessment via a virtual fracture clinic.


Bone & Joint Open
Vol. 3, Issue 2 | Pages 165 - 172
21 Feb 2022
Kuwahara Y Takegami Y Tokutake K Yamada Y Komaki K Ichikawa T Imagama S

Aims

Postoperative malalignment of the femur is one of the main complications in distal femur fractures. Few papers have investigated the impact of intraoperative malalignment on postoperative function and bone healing outcomes. The aim of this study was to investigate how intraoperative fracture malalignment affects postoperative bone healing and functional outcomes.

Methods

In total, 140 patients were retrospectively identified from data obtained from a database of hospitals participating in a trauma research group. We divided them into two groups according to coronal plane malalignment of more than 5°: 108 had satisfactory fracture alignment (< 5°, group S), and 32 had unsatisfactory alignment (> 5°, group U). Patient characteristics and injury-related factors were recorded. We compared the rates of nonunion, implant failure, and reoperation as healing outcomes and Knee Society Score (KSS) at three, six, and 12 months as functional outcomes. We also performed a sub-analysis to assess the effect of fracture malalignment by plates and nails on postoperative outcomes.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 25 - 25
1 May 2018
Chilbule S Qureshi A Hill C Nicolaou N Giles SN Fernandes JA
Full Access

Purpose. Surgical correction of upper limb deformities in severe osteogenesis imperfecta (OI) is technically difficult and less absolving, hence we aimed to analyse the surgical complications of rodding the humeri in severe OI. Methods and results. Retrospective analysis was carried out for consecutive humeral roddings for severe OI in last 3 years. Surgical technique for all humeri included retrograde telescopic nailing (female or both of FD or TST rods) with entry from olecranon fossa, exploration of radial nerve followed by osteotomies. Deformities were quantified and sub-classified as per level of deformity). Variables such as number of osteotomies, radiological union, intraoperative and postoperative complications, improvement in ROM and subjective patient satisfaction were recorded. Total 18 humeri in 12 patients with type III OI (except 1) with mean age of 8.9 years underwent nailing. All patients achieved radiological union at 6–10 weeks. Total 8 complications (44.4 %) were reported within mean 8.4 months follow up. Four segments (22.2 %) had intraoperative fractures at distal third of the humerus while negotiating the nail. Significantly higher intraoperative complications were encountered in humeri fixed with both components combined and upper third level deformities, deformities > 900 and more than 2 osteotomies. Other complications were prominent implant at upper end (2) with growth and one each of contralateral fracture and distal humeral varus. All patients reported improvement in ROM and functional status. Conclusion. Significant complications are associated with humeral nailing for severe OI. Quantification of the deformity with meticulous surgical planning and execution is advised. Despite these complications outcomes show benefits of the surgical treatment. Level of evidence. Therapeutic III


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 32 - 32
1 May 2018
Iliopoulos E Ads T Trompeter A
Full Access

Introduction. Plate fixation for distal femoral fractures is a commonly used method of fracture stabilisation. Many orthopaedic surgeons traditionally do not allow their patients to weight bear for the first 6 weeks after surgery, fearing of loss of fracture reduction and metalwork failure. The aim of this study is to investigate whether the post-operative weight bearing status after plate fixation influences the outcome in terms of loss of reduction and metalwork failure. Materials & Methods. A retrospective data collection from all patients who treated in our hospital surgically for distal femoral fractures, from January 2015 until June 2017. Inclusion criteria were the operative treatment of these fractures with plate fixation. Patients who were treated with retrograde nail, primary total knee replacement or screw fixation were excluded from the study. Patient, injury and surgery demographic data was collected. The immediate post-operative weight bearing status of these patients was noted. Weight bearing status was divided into two groups – Group 1 (Non and touch weight bear – the non-weight bearing group) and Group 2 (Weight bear as tolerated / Full weight bear – the weight bearing group). Radiological data about fracture displacement or metalwork failure was collected at the six weeks and three months follow up after the operation, using a standardised measurement for displacement performed independently by two authors (EI, TA). Results. Of 70 patients, a total of 51 fractures treated with plate fixation were included to the study. The mean age of the cohort was 64.3 ±20.7 years with the majority of the patients being female (63%). Most of the patients (40%) had a complete articular distal femoral fracture, AO Type 33C. Thirty-nine patients (76%) were treated with one lateral distal femoral plate. The total number of the patients in group 1 was 32 (68%); with 17 patients (32%) in group 2. The weight bearing status did not correlate with the fracture type or the fixation type (p>0.05). None of the 6 weeks follow up radiographs revealed fracture displacement in both study groups. Four of the patients from the non-weight bearing group had >1mm displacement at the 3 months' follow-up radiographs. Fisher's exact test revealed no statistically significant difference between the two study groups in both follow-up time points (p=0.55). Two of the patients in the non-weight bearing group had their plate broken at the 3 months follow up and required revision fixation. Conclusion. By reviewing the outcomes in terms of fracture displacement and metalwork failure following plate fixation of distal femoral fractures, early weight bearing of these patients do not jeopardise the outcome of the operation


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 894 - 901
1 Jul 2022
Aebischer AS Hau R de Steiger RN Holder C Wall CJ

Aims

The aim of this study was to investigate the rate of revision for distal femoral arthroplasty (DFA) performed as a primary procedure for native knee fractures using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Data from the AOANJRR were obtained for DFA performed as primary procedures for native knee fractures from 1 September 1999 to 31 December 2020. Pathological fractures and revision for failed internal fixation were excluded. The five prostheses identified were the Global Modular Arthroplasty System, the Modular Arthroplasty System, the Modular Universal Tumour And Revision System, the Orthopaedic Salvage System, and the Segmental System. Patient demographic data (age, sex, and American Society of Anesthesiologists grade) were obtained, where available. Kaplan-Meier estimates of survival were used to determine the rate of revision, and the reasons for revision and mortality data were examined.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 1 - 1
1 Jun 2017
Panagiotopoulou V Davda K Hothi H Henckel J Cerquiglini A Goodier W Skinner J Hart A Calder P
Full Access

Introduction. The Precice nail is the latest intramedullary lengthening nail with excellent early outcomes. Implant complications have led to modification of the nail design. The aim of this study was to perform a retrieval study of Precice nails following lower limb lengthening. To assess macroscopic and microscopic changes to the implants and assess differences following design modification, with identification of potential surgical, implant and patient risk factors. Method. 15 nails were retrieved from 13 patients following lower limb lengthening. Macroscopic and microscopic surface damage to the nails were identified. Further analysis included radiology and micro-CT prior to sectioning. The internal mechanism was then analysed with Scanning Electron Microscopy and Energy Dispersive X-ray Spectroscopy to identify corrosion. Results. 7 male and 3 females underwent 12 femoral lengthenings, 9 antegrade and 3 retrograde. 3 females underwent tibial lengthening. All patients obtained the desired length with no implant failure and full regenerate consolidation. Surface degradation was noted on the telescopic part of every nail design, less on the latest implants. Microscopic analysis confirmed fretting and pitting corrosion. Following sectioning black debris was noted in all implants. The early designs were found to have fractured actuator pins and the pin and bearings had evidence of corrosive debris. The latest designs had evidence of biological deposits suggestive of fluid ingress within the nail. Conclusion. This study suggests fluid ingress occurs with every generation of Precice nail despite modifications. The presence of biological fluid could be an early warning sign of potential corrosion. This in theory could lead to actuator pin fracture and implant failure. The clinical relevance is the potential re-use of a “dormant” nail in patients requiring secondary limb segment lengthening. Retraction of the nail in-situ and re-use for further lengthening requires careful consent for potential implant failure


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 4 - 4
1 Jun 2017
Davda K Wright S Heidari N Calder P Goodier W
Full Access

Introduction. The management of a significant bone defect following excision of a diaphyseal atrophic femoral non-union remains a challenge. Traditional bone transport techniques require prolonged use of an external fixator with associated complications. We present our clinical outcomes using a combined technique of acute femoral shortening, stabilised with a deliberately long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis to restore segment length utilising a temporary monolateral fixator. Method. 9 patients underwent the ‘rail and nail’ technique for the management of femoral non-union. Distraction osteogenesis was commenced on the 6. th. post-operative day. Proximal locking of the nail and removal of the external fixator was performed approximately one month after length had been restored. Full weight bearing and joint rehabilitation was encouraged throughout. Consolidation was defined by the appearance of 3 from 4 cortices of regenerate on radiographs. Results. 7 males and 2 females of adult age underwent treatment between 2009 and 2016. The mean lengthening was 6.6cm (3–10cm). The external fixator was removed at a mean 123 days (57–220), with an external fixation index of 20 days/cm. The regenerate healing index was 28 days/cm. There were no deep infections. Significant complications were seen in 4 patients including knee stiffness, a foot drop, delayed union of the non-union osteotomy (requiring exchange nailing and bone grafting) and revision nailing due to a prominent proximal tip. Conclusion. The combined over-sized intramedullary nail and external fixator enables compression of the femoral osteotomy, alignment of the bone and controlled lengthening. Once the length has been restored, removal of the external fixator and proximal locking of the nail reduces the risk of complications associated with the fixator and stabilises the femur with the maximum working length of the nail. This small retrospective study demonstrates encouraging results for this complex clinical scenario


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 4 - 4
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:. Leg length discrepancy related to absence of the femoral head with proximal migration of the femur presents a treatment dilemma. Late sequelae of neonatal hip sepsis and chronic hip dislocation due to developmental dysplasia are the most common causes. Traditional teaching dictates that the hip is stabilised prior to limb lengthening. Reconstructive options alter the shape of the proximal femur which complicates future surgery. Methods:. We retrospectively reviewed 3 cases of femoral lengthening with an ‘unstable’ hip without prior stabilization. The aetiology was neonatal hip sepsis in 2 cases and chronic hip dislocation due to developmental dysplasia in 1 case. Lengthening was performed with the use of a retrograde Precice lengthening nail. Results and Discussion:. The desired length (range 5.5 to 6cm) was achieved in all patients without migration of the proximal femur. In all cases patient satisfaction was high with the lengthening and the ability to abort shoe raises. There was an improvement in gait pattern in all patients. Conclusion:. Femoral lengthening is possible without prior stabilisation of the hip in so called ‘unstable’ hip situations. The proximal femoral anatomy is not further altered and future salvage procedures such as a total hip replacement are not compromised


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims

The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing.

Methods

A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 512 - 512
1 Sep 2012
Zlowodzki M Armitage B Wijdicks C Kregor P Bruce L Cole P
Full Access

Introduction. The most common treatment options for fixation of osteoporotic distal femur fractures are retrograde nails and locking plates. There are proponents of more elastic titanium plates as well as more rigid steel plates; No clear superiority of one over the other has been established. We aimed to evaluate the mechanical differences between stainless steel and titanium locking plates in the fixation of distal femur fractures in osteoporotic bone. We hypothesized that due to its higher elasticity titanium locking plates can absorb more energy and are therefore less likely to “cut” into the bone compared to stainless steel locking plates resulting in improved metaphyseal osteoporotic fracture fixation. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Within each pair we randomized one femur to be fitted with a Less Invasive Stabilization System (LISS-Titanium locking plate) and one with a Distal Locking Condylar Plate (DLCP-Stainless steel locking plate). A fracture model simulating an AO 33-A3 fracture was created (extraarticular comminuted fracture) and specimens were subsequently subjected to step-wise cyclic axial loading to failure. We used an advanced three dimensional tracking system (Polhemus Fastrak) to monitor the movement of the distal fragment relative to the real time distal plate position allowing us to evaluate distal implant cut-out. Results. During cyclic testing, seven of the eight pairs of matched femurs, the DLCP failed before the LISS plate (p=0.03). All constructs were able to withstand cyclical loading up to 800N. The overall plastic deformation as measured by the displacement of the Instron crosshead experienced by the titanium plate constructs was significantly lower compared to the stainless steel plate construct: The plastic deformation of the LISS plates was 39% lower compared to the Locking Condylar plates after cycle testing at 400 Newtons and 70% lower at 800N. Furthermore during the 800N cycle testing the LISS plating system showed a significantly lower rate of plastic deformation not only for the entire bone-implant construct, but also between the plate and the distal fragment than the locking condylar plate (=less distal implant cut-out). Conclusions. The use of a more advanced three dimensional tracking system, fresh-frozen osteoporotic matched human specimen and the ability to test all constructs to failure allowed us a more thorough comparison of titanium versus stainless steel implants compared to previous studies. The titanium locking plates provided an overall superior fixation of osteoporotic distal femur fractures with less distal implant cut-out, a better elastic recoil, and a slower rate of residual plastic deformation