Background. The traditional Kocher approach for lateral elbow exposure is often complicated by injury to the posterior interosseous nerve (PIN) and the lateral ulnar collateral ligamentous (LUCL). Kaplan approach is less commonly used, due to its known proximity to the PIN. Extensor Digitorum Communis (EDC) splitting approach allows possible wide surgical exposure and low risk of LUCL damage. The comparison of PIN injury during surgical dissection among these 3 common lateral approaches was not previously evaluated. We aim to determine the anatomical proximity of the PIN in these 3 common lateral elbow approaches and to define a safe zone of dissection for the surgical exposure. Methods. Cadaveric dissections of 9 pairs of fresh frozen adult upper extremities were performed using EDC splitting, Kaplan and Kocher approach to the
Background.
3D printing and rapid prototyping in surgery is an expanding technology. It is often used for preoperative planning, procedure rehearsal and patient education. There have been recent advances in orthopaedic surgery for the development of patient specific guides and jigs. The logical next step as the technology advances is the production of custom orthopaedic implants. I aimed to use freely available open source software and online cloud 3D printing services to produce a patient specific orthopaedic implant without requiring the input of a university department, specialised equipment or implant companies. Using standard CT scan DICOM data, a 3D surface reconstruction was made of a patient's uninjured
Intervention is rare following minimally displaced
We have evaluated four different fixation techniques for the reconstruction of a standard Mason type-III fracture of the
Coronoid fractures account for 2 to 15% of the cases with elbow dislocations and usually occur as part of complex injuries. Comminuted fractures and non-unions necessitate coronoid fixation, reconstruction or replacement. The aim of this biomechanical study was to compare the axial stability achieved via an individualized 3D printed prosthesis with curved cemented intramedullary stem to both
Summary. Consistent load distributions with over-sizing of
Summary Statement. We are taking very expensive cutting edge technology, usually reserved for industry, and using it with the help of open source free software and a cloud 3D printing services to produce custom and anatomically unique patient individual implants for only £32. This is approx. 1/100. th. of the traditional cost of implant production. Introduction. 3D printing and rapid prototyping in surgery is an expanding technology. It is often used for preoperative planning, procedure rehearsal and patient education. There have been recent advances in orthopaedic surgery for the development of patient specific guides and jigs. The logical next step as the technology advances is the production of custom orthopaedic implants. Our aim was to use freely available open source software, a personal computer and consumer access online cloud 3D printing services to produce an accurate patient specific orthopaedic implant without utilising specialist expertise, capital expenditure on specialist equipment or the involvement of traditional implant manufacturing companies. This was all to be done quickly, cost effectively and in department. Methods & Materials. Using standard computed tomography (CT) scan and the standard file format of digital imaging and communications in medicine (DICOM) data, a 3D surface reconstruction was made of a cadaveric
Repeated trauma to the
Advancements in treating the unstable elbow. We will review and discuss the kinematics and biomechanics of the forearm, concentrating on the role of soft tissue structures and how they affect forearm and elbow function. During this session, we will review the latest techniques for treating the terrible triad, including solutions to complex injuries of the olecranon, coronoid, and
We undertook a study on eight arms from fresh cadavers to define the clinical usefulness of the lesser sigmoid notch as a landmark when reconstructing the length of the neck of the radius in replacement of the head with a prosthesis. The head was resected and its height measured, along with several control measurements. This was compared with in situ measurements from the stump of the neck to the proximal edge of the lesser sigmoid notch of the ulna. All the measurements were performed three times by three observers acting independently. The results were highly reproducible with intra- and interclass correlations of >
0.99. The mean difference between the measurement on the excised head and the distance from the stump of the neck and the lesser sigmoid notch was −0.02 mm (−1.24 to +0.97). This difference was not statistically significant (p = 0.78). The proximal edge of the lesser sigmoid notch provides a reliable landmark for positioning a replacement of the
Summary. The significance of matching radius of curvature of the
Introduction. The stability of the elbow joint following an acute elbow dislocation is dependent on associated injuries. The ability to identify these concomitant injuries correctly directs management and improves the chances of a successful outcome. Interpretation of plain radiographs in the presence of either a dislocation or post-reduction films with plaster in-situ is difficult. This study aimed to assess the ability of orthopaedic registrars to accurately identify associated bony injuries on initial plain radiographs using CT as the gold standard for comparison. Methods. Patients over the age of 16 years undergoing an elbow CT scan within one week of a documented elbow dislocation between 1st June 2010 and 1st June 2014 were included in the study. Three orthopaedic registrars independently reviewed both the initial dislocation and immediate post reduction plain radiographs to identify any associated bony injuries. This radiograph review was repeated by each registrar after two weeks. The incidence of associated injuries as well as the inter- and intra-observer variability was calculated. Results. 28 patients were included in the study. 54% of the patients were female and the mean age was 45 years (range 16 to 90 years). The incidence of a
3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting. For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer. PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated
Background. The pattern of appearance of secondary ossification centers in the elbow has been based on historical studies and is popularly referred to with the mnemonic CRITOL. However the six secondary ossification centers can be variable in their presentation and pose a challenge in assessment of children with elbow injuries. Furthermore limited studies available in the current literature have reported an aberration to the sequence of appearance especially with the ossification centers of trochlea and olecranon. Aims. The aim of the study was to evaluate the relative sequence of appearance of secondary ossification centers for the trochlea and olecranon. Methods. Children between 8 and 10 years of age who had radiographs of elbow following trivial trauma between July 2013 and Feb 2015 were identified using the hospital PACS database. Cases with radiographic markers of significant trauma ie. fat pad sign, displaced fracture were excluded. Anteroposterior and lateral views of elbow were reviewed for the presence of the six ossification centers. Results. A total of 114 radiographs were reviewed of which 51 were boys and 63 were girls with a mean age of 9.03 years (±0.59). 60 radiographs were of right elbow and 54 were of the left elbow. The capitulum,
Posterolateral rotatory instability (PLRI) is the most common type of elbow instability. It is caused by an insufficiency of the lateral ligamentous complex, which consists mainly of the radial collateral ligament (RCL) and the lateral ulnar collateral ligament (LUCL). Investigate the influence of serial sectioning of the lateral ligamentous complex on elbow stability in a cadaveric model of PLRI. Kinematics of six fresh frozen cadaveric elbow specimens were measured by digitizing anatomical marks with a Microscribe 3DLX digitizing system (Revware Inc, Raleigh, NC). Each specimen was tested under four conditions: Intact, LUCL tear, LUCL and RCL tear, and complete Tear (LUCL, RCL and capsule tear). Each specimen was tested in 30°, 60° and 90° elbow flexion angles. Varus- laxity was measured in supination, pronation, and neutral forearm rotation positions and total forearm rotation was measured with 0.3 Nm of torque. Statistical significant differences between the conditions were detected using a two-way ANOVA with Tukey's post-hoc test. The
Summary. Increased lateral ulnotrochlear joint space due to improper sizing in radial head arthroplasty may result in medial collateral ligament laxity, leading to increased osteophytes and arthritis. Introduction.