Advertisement for orthosearch.org.uk
Results 1 - 15 of 15
Results per page:
Bone & Joint Open
Vol. 2, Issue 3 | Pages 150 - 163
1 Mar 2021
Flett L Adamson J Barron E Brealey S Corbacho B Costa ML Gedney G Giotakis N Hewitt C Hugill-Jones J Hukins D Keding A McDaid C Mitchell A Northgraves M O'Carroll G Parker A Scantlebury A Stobbart L Torgerson D Turner E Welch C Sharma H

Aims. A pilon fracture is a severe ankle joint injury caused by high-energy trauma, typically affecting men of working age. Although relatively uncommon (5% to 7% of all tibial fractures), this injury causes among the worst functional and health outcomes of any skeletal injury, with a high risk of serious complications and long-term disability, and with devastating consequences on patients’ quality of life and financial prospects. Robust evidence to guide treatment is currently lacking. This study aims to evaluate the clinical and cost-effectiveness of two surgical interventions that are most commonly used to treat pilon fractures. Methods. A randomized controlled trial (RCT) of 334 adult patients diagnosed with a closed type C pilon fracture will be conducted. Internal locking plate fixation will be compared with external frame fixation. The primary outcome and endpoint will be the Disability Rating Index (a patient self-reported assessment of physical disability) at 12 months. This will also be measured at baseline, three, six, and 24 months after randomization. Secondary outcomes include the Olerud and Molander Ankle Score (OMAS), the five-level EuroQol five-dimenison score (EQ-5D-5L), complications (including bone healing), resource use, work impact, and patient treatment preference. The acceptability of the treatments and study design to patients and health care professionals will be explored through qualitative methods. Discussion. The two treatments being compared are the most commonly used for this injury, however there is uncertainty over which is most clinically and cost-effective. The Articular Pilon Fracture (ACTIVE) Trial is a sufficiently powered and rigorously designed study to inform clinical decisions for the treatment of adults with this injury. Cite this article: Bone Jt Open 2021;2(3):150–163


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1100 - 1106
1 Aug 2010
Kapoor SK Kataria H Patra SR Boruah T

Open reduction and internal fixation of high-energy pilon fractures are often associated with serious complications. Various methods have been used to treat these injuries, with variable results. A total of 17 consecutive patients with pilon fractures of AO/OTA type 43-B3 (n = 1), type C2 (n = 12) and type C3 (n = 4) were treated by indirect reduction by capsuloligamentotaxis and stabilisation using an ankle-spanning Ilizarov fixator. The calcaneal ring was removed at a mean of 3.7 weeks (3 to 6). A total of 16 patients were available for follow-up at a mean of 29 months (23 to 43). The mean time to healing was 15.8 weeks (13 to 23). Nine patients had pin-track infections but none had deep infection or osteomyelitis. Four patients (25%) had malunion. Fair, good or excellent ankle scores were found in 14 patients. External fixation with a ring fixator achieves stable reduction of the fractured fragments without additional trauma to soft tissues. With minimum complications and good healing results, the Ilizarov apparatus is particularly useful for high-energy pilon fractures


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 7 - 7
10 Jun 2024
Hill D Davis J
Full Access

Introduction. Tibial Pilon fractures are potentially limb threatening, yet standards of care are lacking from BOFAS and the BOA. The mantra of “span, scan, plan” describes staged management with external fixation to allow soft tissue resuscitation, followed by a planning CT-scan. Our aim was to evaluate how Tibial Pilon fractures are acutely managed. Methods. ENFORCE was a multi-centre retrospective observational study of the acute management of partial and complete articular Tibial Pilon fractures over a three-year period. Mechanism, imaging, fracture classification, time to fracture reduction and cast, and soft tissue damage control details were determined. Results. 656 patients (670 fractures) across 27 centres were reported. AO fracture classifications were: partial articular (n=294) and complete articular (n=376). Initial diagnostic imaging mobilities were: plain radiographs (n=602) and CT-scan (n=54), with all but 38 cases having a planning CT-scan. 526 fractures had a cast applied in the Emergency Department (91 before radiological diagnosis), with the times taken to obtain post cast imaging being: mean 2.7 hours, median 2.3 hours, range 28 mins – 14 hours). 35% (102/294) of partial articular and 57% (216/376) of complete articular (length unstable) fractures had an external fixator applied, all of which underwent a planning CT-scan. Definitive management consisted of: open reduction internal fixation (n=495), fine wire frame (n=86), spanning external fixator (n=25), intramedullary nail (n=25), other (n=18). Conclusion. The management of Tibial Pilon fractures is variable, with prolonged delays in obtaining post cast reduction radiographs, and just over half of length unstable complete articular fractures being managed with the gold standard “span, scan, plan” staged soft tissue resuscitation. A BOFAS endorsed BOAST (British Orthopaedic Association Standard for Trauma) for Tibial Pilon fractures is suggested for standardisation of the acute management of these potentially limb threatening injuries, together with setting them apart from more straightforward ankle fractures


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 6 - 6
1 Apr 2013
Kakwani R Ramaskandhan J Siddique M
Full Access

Aim. A prospective cohort of patients undergoing total ankle arthroplasrty for arthritis following pilon fractures was included in the present study. This group of patients generally have poor soft tissue envelope and have had previous surgical interventions prior to the ankle arthroplasty, making the arthroplasty more difficult as well as prone to complications. Methods. The data collected included patient demographics, American Orthopaedic Foot and Ankle Score (AOFAS) and patient reported outcomes (FAOS, SF-36, patient satisfaction) The data was collected preoperatively and at 1 & 2 years postoperatively. The minimum follow-up period was 2 years post-operatively. Results. A total of 167 total ankle arthroplasties were performed by the senior author between Jan 2006 and June 2010. Of this cohort, the indication for 12 arthroplasties was arthritis following pilon fractures of the distal tibia. The average of the patients at the time of the surgery was 64.2yrs. The average number of previous surgeries prior to the ankle arthroplasty was 1.5. There were significant improvements in the AOFAS scores from an average of 18 to 75 at final review. The WOMAC scores improved from 31 to 71 for pain, stiffness improved from 31 to 60 and function improved from 33 to 63. The improvement of the SF36 and patient satisfaction score is similar to the ones for primary ankle osteoarthritis. The complications were: 1 case of superficial wound infection which settled with antibiotics, one fracture of medial malleolus and one case of undisplaced distal tibial fracture treated conservatively to union. Conclusion. The Indications for TAR can be safely broadened to include younger patients with arthritis following pilon fractures of the tibia. The Outcomes after TAR for patients with arthritis following pilon fractures are comparable to those for primary osteo arthritis of the ankle


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 23 - 23
8 May 2024
Jayatilaka M Fisher A Fisher L Molloy A Mason L
Full Access

Introduction. The treatment of posterior malleolar fractures is developing. Mason and Molloy (Foot Ankle Int. 2017 Nov;38(11):1229-1235) identified only 49% of posterior malleolar rotational pilon type fractures had syndesmotic instabilities. This was against general thinking that fixation of such a fragment would stabilize the syndesmosis. Methods. We examined 10 cadaveric lower limbs that had been preserved for dissection at the Human Anatomy and Resource Centre at Liverpool University in a solution of formaldehyde. The lower limbs were carefully dissected to identify the ligamentous structures on the posterior aspect of the ankle. To compare the size to the rotational pilon posterior malleolar fracture (Mason and Molloy 2A and B) we gathered information from our posterior malleolar fracture database. 3D CT imaging was analysed using our department PACS system. Results. The PITFL insertion on the posterior aspect of the tibia is very large. The average size of insertion was 54.9×47.1mm across the posterior aspect of the tibia. Medially the PITFL blends into the sheath of tibialis posterior and laterally into the peroneal tendon sheath. 78 posterior lateral and 35 posterior medial fragments were measured. On average, the lateral to medial size of the posteromalleolar fragment was 24.5mm in the posterolateral fragment, and 43mm if there is a posteromedial fragment present also. The average distal to proximal size of the posterolateral fragment was 24.5mm and 18.5mm for the posteromedial fragment. Conclusion. The PITFL insertion on the tibia is broad. In comparison to the average size of the posterior malleolar fragments, the PITFL insertion is significantly bigger. Therefore, for a posterior malleolar fracture to cause posterior syndesmotic instability, a ligamentous injury will also have to occur. This explains the finding by Mason and Molloy that only 49% of type 2 injuries had a syndesmotic injury on testing


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 8 - 8
1 Jan 2014
Lomax A Singh A Madeley N Kumar C
Full Access

Introduction:. In this cohort study, we present comprehensive injury specific and surgical outcome data from one of the largest reported series of distal tibial pilon fractures, treated in our tertiary referral centre. Methods:. A series of 76 pilon fractures were retrospectively reviewed from case notes, plain radiographs and computed tomography (CT) imaging. Patient demographics, injury and fracture patterns, methods and timing of fixation and clinical and radiological outcomes were assessed over a mean follow up period of 8.6 months (range 2–30). Results:. Definitive fixation was most commonly performed through an open technique with plate fixation. CT imaging was used to plan the most direct approach to access the fracture fragments. The majority of cases were classified as AO/OTA 43.C3. When definitive open fixation for closed fracture was performed within 48 hours, the rate of deep infection or wound complication was 0%. When performed on day 3–5, the deep infection rate was 0% but the superficial wound complication rate was 23.5%. From day six onwards, the deep infection rate was 4% and the superficial wound complication rate was 8%. The rate of wound complications after double plate fixation of the tibia using two separate incisions was 23.1%, compared to 11.7% after single incision and plating. The rate of non-union was 9.7%. Symptomatic post-traumatic arthritis requiring orthopaedic management occurred in 9.9%. Further surgery was required in 27.8% of all patients. Conclusion:. Outcomes from our unit compare favourably with those from large trauma centres worldwide. Our study supports the use of early definitive fixation, within 48 hours, to achieve low rates of wound complications. We support an “unsafe window” for definitive fixation of three to five days post injury due to the high rate of wound complications. The likelihood of developing post-traumatic arthritis and of requiring further surgery is high


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 18 - 18
1 Nov 2014
Walker R Bolton S Nash W Jones I Abbasian A
Full Access

Introduction:. The Best Practice Tariff (BPT) for hip fractures was introduced in April 2010 to promote a number of quality markers, including surgery within 36 hours. We conducted an audit to see whether the introduction of the BPT has had an inadvertent adverse effect on delay to fixation of unstable ankle fractures. Method:. We compared the delay to surgery for 50 consecutive patients with unstable ankle fractures in the 2009 financial year with another 50 patients treated in the 2011 financial year, ie one year after the introduction of the BPT. There were no other changes in service in our department in this period. All radiographs were reviewed and classified using the Lauge-Hansen system by 2 surgeons. Excel was used for data analysis using unpaired T-Test and chi-squared test to assess significance. Results:. 2 patients with pilon fractures were excluded from each group. Demographics and fracture pattern between the remaining 48 patients in each group were similar. The mean delay to surgery before BPT was 2.2 days compared with 3.8 days after its introduction (p = 0.01). 7 patients waited more than 5 days for surgery before BPT compared with 17 patients after its introduction (p < 0.001). There was 1 manipulation under anaesthetic (MUA) before BPT and 8 MUAs in 7 patients after its introduction (p < 0.001). Conclusion:. There is a significant association between the introduction of BPT for hip fractures and an increase in the delay to surgery for patients with unstable ankle fractures by an average of 1.6 days. More patients waited more than 5 days for surgery and there were more MUAs. We postulate that in a resource-limited NHS, prioritizing one patient group inevitably disadvantages others. Orthopaedic trauma services must adapt to national guidance to ensure all patients are treated in a timely fashion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 35 - 35
1 Sep 2012
Choi C Hakim Z Lattouf G Shoaib A
Full Access

The treatment of very distal tibial fractures and pilon fractures is difficult. There is a wide variation in the severity of injury and the options for surgical management. Plates and external fixation each have their advantages. This retrospective study looks at complications and technical tips for anterolateral plating. 35 consecutive distal tibial platings were evaluated. The AO classification for each fracture was determined and any patient factors affecting outcome. Outcome variables included time to radiological union, infection rate, wound breakdown rate, and joint movement after treatment. There were 32 anterolateral platings and 3 medial platings. The union rate was 95%. There were two deep infections which required surgical treatment. There were two wound breakdowns, one of which required plastic surgical intervention. Two patients had prominent metalwork, requiring removal. Other complications included deep peroneal nerve palsy, stiffness, and vascular compromise. The complication rates were lower for surgeons operating more frequently on these fractures. Two patients subsequently required bone transport and one required an amputation. The complication rate found was similar to that reported in the literature. The few complications were however very significant for the patient and also for the surgeon as they required bone transport. Complications other than infection occurred in the few cases performed by surgeons low on their learning curve. We present technical tips for surgery. The presence of callus only after mobilisation indicates that union is slow. Anterolateral plating is a viable option for distal tibial fractures, especially 43B fractures. There is a learning curve associated with their use. Complication rates are low overall, but significant consequences can accompany complications. As an alternative to external fixation, distal locking plates are not a pain free option for the surgeon, as well as for the patient


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1054 - 1059
1 Aug 2018
Kelly C Harwood PJ Loughenbury PR Clancy JA Britten S

Aims

Anatomical atlases document classical safe corridors for the placement of transosseous fine wires through the calcaneum during circular frame external fixation. During this process, the posterior tibial neurovascular bundle (PTNVB) is placed at risk, though this has not been previously quantified. We describe a cadaveric study to investigate a safe technique for posterolateral to anteromedial fine wire insertion through the body of the calcaneum.

Materials and Methods

A total of 20 embalmed cadaveric lower limbs were divided into two groups. Wires were inserted using two possible insertion points and at varying angles. In Group A, wires were inserted one-third along a line between the point of the heel and the tip of the lateral malleolus while in Group B, wires were inserted halfway along this line. Standard dissection techniques identified the structures at risk and the distance of wires from neurovascular structures was measured. The results from 19 limbs were subject to analysis.


The Bone & Joint Journal
Vol. 101-B, Issue 4 | Pages 447 - 453
1 Apr 2019
Sanders FRK Backes M Dingemans SA Hoogendoorn JM Schep NWL Vermeulen J Goslings JC Schepers T

Aims

The aim of this study was to evaluate the functional outcome in patients undergoing implant removal (IR) after fracture fixation below the level of the knee.

Patients and Methods

All adult patients (18 to 75 years) undergoing IR after fracture fixation below the level of the knee between November 2014 and September 2016 were included as part of the WIFI (Wound Infections Following Implant Removal Below the Knee) trial, performed in 17 teaching hospitals and two university hospitals in The Netherlands. In this multicentre prospective cohort, the primary outcome was the difference in functional status before and after IR, measured by the Lower Extremity Functional Scale (LEFS), with a minimal clinically important difference of nine points.


The Bone & Joint Journal
Vol. 99-B, Issue 11 | Pages 1496 - 1501
1 Nov 2017
Bali N Aktselis I Ramasamy A Mitchell S Fenton P

Aims

There has been an evolution recently in the management of unstable fractures of the ankle with a trend towards direct fixation of a posterior malleolar fragment. Within these fractures, Haraguchi type 2 fractures extend medially and often cannot be fixed using a standard posterolateral approach. Our aim was to describe the posteromedial approach to address these fractures and to assess its efficacy and safety.

Patients and Methods

We performed a review of 15 patients with a Haraguchi type 2 posterior malleolar fracture which was fixed using a posteromedial approach. Five patients underwent initial temporary spanning external fixation. The outcome was assessed at a median follow-up of 29 months (interquartile range (IQR) 17 to 36) using the Olerud and Molander score and radiographs were assessed for the quality of the reduction.


The Bone & Joint Journal
Vol. 100-B, Issue 6 | Pages 755 - 760
1 Jun 2018
Lou T Hamushan M Li H Wang C Chai Y Han P

Aims

The aim of this study was to describe the technique of distraction osteogenesis followed by arthrodesis using internal fixation to manage complex conditions of the ankle, and to present the results of this technique.

Patients and Methods

Between 2008 and 2014, distraction osteogenesis followed by arthrodesis using internal fixation was performed in 12 patients with complex conditions of the ankle due to trauma or infection. There were eight men and four women: their mean age was 35 years (23 to 51) at the time of surgery. Bone healing and functional recovery were evaluated according to the criteria described by Paley. Function was assessed using the ankle-hindfoot scale of the American Orthopedic Foot and Ankle Society (AOFAS).


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1055 - 1058
1 Aug 2008
Lee HS Kim JS Park S Lee D Park JM Wapner KL

We studied 11 patients with checkrein deformities of the hallux who underwent surgical treatment. Six had lengthening of the flexor hallucis longus tendon by Z-plasty in the midfoot, and five underwent release of adhesions and lengthening of the tendon by Z-plasty at the musculotendinous junction at the fracture site.

All six patients who underwent Z-plasty at the midfoot showed complete correction of the deformity without recurrence. Of the five who had release of adhesions and Z-plasty of the tendon at the fracture site, two showed partial and one showed complete recurrence.


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 371 - 377
1 Mar 2013
Kugan R Aslam N Bose D McNally MA

Achieving arthrodesis of the ankle can be difficult in the presence of infection, deformity, poor soft tissues and bone loss. We present a series of 48 patients with complex ankle pathology, treated with the Ilizarov technique. Infection was present in 30 patients and 30 had significant deformity before surgery. Outcome was assessed clinically and with patient-reported outcome measures (Modified American Orthopaedic Foot and Ankle Society (MAOFAS) scale and the Short-Form (SF-36)).

Arthrodesis was achieved in 40 patients with the Ilizarov technique alone and in six further patients with additional surgery. Infection was eradicated in all patients at a mean follow-up of 46.6 months (13 to 162). Successful arthrodesis was less likely in those with comorbidities and in tibiocalcaneal fusion compared with tibiotalar fusion.

These patients had poor general health scores compared with the normal population before surgery. The mean MAOFAS score improved significantly from 24.3 (0 to 90) pre-operatively to 56.2 (30 to 90) post-operatively, but there was only a modest improvement in general health; the mean SF-36 improved from 44.8 (19 to 66) to 50.1 (21 to 76). There was a major benefit in terms of pain relief.

Arthrodesis using the Ilizarov technique is an effective treatment for complex ankle pathology, with good clinical outcomes and eradication of infection. However, even after successful arthrodesis general health scores remain limited.

Cite this article: Bone Joint J 2013;95-B:371–7.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1060 - 1063
1 Aug 2007
Singh PJ Perera NS Dega R

We carried out a prospective study over a period of 12 months to measure the exposure to radiation of the hands of a dedicated foot and ankle surgeon. A thermoluminescent dosimeter ring (TLD) was used to measure the cumulative dose of radiation. Fluoroscopy was used in operations on the foot and ankle. The total screening time was 3028 s, with a mean time per procedure of 37.4 s (0.6 to 197). This correlated positively with the number of procedures performed (r = 0.92, p < 0.001), and with the dose of radiation in both the left (r = 0.85, p = 0.0005) and right TLDs (r = 0.59, p = 0.419). There was no significant difference in the dose of radiation between the two hands (t-test, p = 0.62). The total dose to the right TLD over the 12 months was 2.4 millisieverts.

This is a simple and convenient method for evaluating the exposure of a single surgeon to radiation. The radiation detected was well below the annual dose limit set by the International Commission on Radiological Protection.