There has been extensive research into neck of femur fractures in the elderly. Fragility non-hip femoral fractures share many of the same challenges [1]. Surgical management is complex, patients are frail and mortality rates have been reported as high as 38% [2]. Despite this, relatively little data is available evaluating the level of MDT care provided to non-hip femoral fractures. This audit aimed to evaluate the standard of MDT care provided for patients with non-hip femoral fractures according to the NHFD key performance indicators. The following fractures were included in the dataset: distal femoral, femoral shaft and peri-prosthetic femoral. Patients under 65 were excluded. Data was retrospectively collected using post-operative and medical documentation. Performance was assessed according to five key performance indicators:. Did orthogeriatrics review the patient within 72-hours?. Was surgery performed within 36-hours?. Was the patient weight bearing post-operatively?. Was a confusion assessment completed?. Was the patient discharged home?. 38 patients met the inclusion criteria. 84% of patients were seen by orthogeriatrics within 72 hours of admission. 32% of patients were operated on within 36-hours of admission, with time to theatre exceeding 36-hours in 92% of
Cannulated hip screws are frequently used in the management of hip fractures. There have been concerns over the failure rate of the technique and the outcomes of those that subsequently require conversion to total hip replacement (THR). This study utilised a database of over 600 cannulated hip screw (CHS) fixations performed over a 14-year period and followed up for a minimum of one year (1-14). We identified 57 cases where a conversion to THR took place (40 females, 17 males, mean age: 71.2 years). Patient demographics, original mechanism of injury, fracture classification, reason for fixation failure, time until arthroplasty, implant type and post-arthroplasty complications were recorded. Clinical outcomes were measured using the Oxford Hip Score. The failure rate of cannulated screw treatment was 9.4% and the mean time from initial fixation to arthroplasty was 15.4 (16.5) months. Thirty six fractures were initially undisplaced and 21 were displaced. As one might expect the displaced cases tended to be younger but this didn't reach statistical significance [66.5(14.3) vs 72.7(13.1), p=0.1]. The commonest causes of failure were non-union (25 cases, 44%) and avascular necrosis (17 cases, 30%). Complications after THR consisted of one leg length discrepancy and one
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A
With increasing numbers of total joint arthroplasties being performed,
Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3),
Neck of femur fractures are a common presentation and certain patients can be managed with a total hip replacement. To receive a total hip replacement the pelvic X-rays should be templated as per AO guidelines and a common way this is performed is by including a calibration marker on the X-ray. The aim of this study is to assess and improve upon the use of the calibration marker. Details of patients admitted with a neck of femur fracture from January 1st 2018 until December 31st 2018 were gathered and used to review each initial X-ray and determine if a calibration marker was included. 376 patients were admitted with a neck of femur fracture over the one year period. 36% of patients did not have a calibration marker on their initial pelvic X-ray and 11% did not have a chest X ray. 215 patients had an intracapsular fracture and 39 went on to have a total hip replacement. 12 patients were lacking a calibration marker on their original X ray and required a repeat X ray. After a poster was placed in the radiographer booth acting as a visual aid, the use of a calibration marker improved from 62% to 70%. Calibration markers are useful tools which can aid the pre-operative planning for hip replacement surgeries shortening operative time, increase precision and reduce prosthetic loosening, lowers the risk of
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A
Total knee arthroplasty (TKA) is a common orthopaedic procedure with over 1,500 done in 2016 in Ireland alone. 96% of all TKAs are due to pain in the knee associated with osteoarthritis. According to the UK National Joint Registry (NJR), there is a 0.47%, 1.81%, 2.63% and 4.34% probability risk of undergoing a revision TKA within one, three, five and ten years respectively post-index surgery. A variety of reasons for failure of TKA have been described in the literature including infection, aseptic loosening, pain, instability, implant wear, mal-alignment, osteolysis, dislocation,
Background. There is a paucity of long term data concerning the pre and postoperative patient reported function of total knee replacement. The aim of this study was to determine the mortality, implant survivorship, patient reported function and satisfaction in a cohort of 114 patients, from a single centre, who received a Kinemax total knee replacement more than 15 years ago. Methods. Patients completed a questionnaire incorporating validated disease- and joint-specific scores, patient satisfaction and overall health preoperatively, at 3 months, 1 year, 2 years and a minimum of 15 years following surgery. NHS National Strategic Tracing Service, hospital and primary care records were used to establish mortality and for implant survivorship in deceased patients. Results. 45 patients were alive at final follow up. The survivorship of the cohort with revision of the TKR as the endpoint was 84%. Four cases were revised for wear, three for loosening and one for
Although cemented fixation provides excellent results in primary total hip replacement (THR), particularly in patients older than 75 years, uncemented implants are most commonly used nowadays. We compare the rate of complications, clinical and radiological results of three different designs over 75-years-old patients. 433 hips implanted in patients over 75 years old were identified from our Local Joint Registry. Group A consisted of 139 tapered cemented hips, group B of 140 tapered grit-blasted uncemented hips and group C of 154 tapered porous-coated uncemented hips. A 28 mm femoral head size on polyethylene was used in all cases. The mean age was greater in group A and the physical activity level according to Devane was lower in this group (p<0.001 for both variables). Primary osteoarthritis was the most frequent diagnoses in all groups. The radiological acetabular shape was similar according to Dorr, however, an osteopenic-cylindrical femur was most frequently observed in group A (p<0.001). The pre- and post-operative clinical results were evaluated according to the Merle-D'Aubigne and Postel scale. Radiological cup position was assessed, including hip rotation centre distance according to Ranawat and cup anteversion according to Widmer. We also evaluated the lever arm and height of the greater trochanter distances and the stem position. Kaplan-Meier analysis was done for revision for any cause and loosening. The hip rotation centre distance was greater and the height of the greater trochanter was lower in group B (p=0.003, p<0.001, respectively). The lever arm distance was lower in group C (p<0.001). A varus stem position was more frequently observed in group B (p<0.001). There were no intra- or post-operative fractures in group A, although there were five intra-operative fractures in the other groups plus two post-operative fractures in group B and four in group C. The rate of dislocation was similar among groups and was the most frequent cause for revision surgery (8 hips for the whole series). The mean post-operative clinical score improved in all groups. The overall survival rate for revision for any cause at 120 months was 88.4% (95% CI 78.8–98), being 97.8% (95% CI 95.2–100) for group A, 81.8% (95% CI 64.8–98.8) for group B and 95.3% (95% CI 91.1–99.6) for group C (log Rank: 0.416). Five hips were revised for loosening. The overall survival rate for loosening at 120 months was 91.9% (95% CI 81.7–100), being 99.2%(95% CI 97.6–100) for group A, 85.5 (95% CI 69.9 −100) for group B and 100% for group C (Log Rank 0.093). Despite a more osteopenic bone in the cemented group, the rate of
Aims. Osteoporosis and abnormal bone metabolism may prove to be significant
factors influencing the outcome of arthroplasty surgery, predisposing
to complications of aseptic loosening and
We present a novel use for an adult proximal humeral locking plate. In our case an 18-year-old female with cerebral palsy sustained a
Background. Implant stability and is an important factor for adequate bone remodelling and both are crucial in the long-term clinical survival of total hip arthroplasty (THA). Assessment of early bone remodelling on X-rays during the first 2 years post-operatively is mandatory when stepwise introduction of a new implant is performed. Regardless of fixation type (cemented or cementless), early acetabular component migration is usually the weakest link in THA, eventually leading to loosening. Over the past years, a shift towards uncemented cup designs has occurred. Besides the established hydroxyapatite (HA) coated uncemented cups which provide ongrowth of bone, new uncemented implant designs stimulating ingrowth of bone have increased in popularity. These cups initiate ingrowth of bone into the implant by their open metallic structure with peripheral pores, to obtain a mechanical interlock with the surrounding bone, thereby stabilising the prosthesis in an early stage after implantation. This retrospective study assessed bone remodelling, osseointegration and occurrence of radiolucency around a new ingrowth philosophy acetabular implant. Methods. In a retrospectively, single centre cohort study all patients whom underwent primary THA with a Tritanium acetabular component in 2011 were included. Bone remodelling, osseointegration and occurrence of radiolucency were determined by two reviewers from X-ray images that were made at 6 weeks, 3–6-12 and 24 months post-operatively. Bone contact % was calculated based on the original Charnley and DeLee zones. According to Charnley and DeLee the outer surface of an acetabular cup is divided into 3 zones (1-2-3). For our analysis the original 3 zones were further divided into 2 producing 6 zones 1A to 3B. Each of these 6 zones were then further divided into 4 equal sections. We attributed 25 points per section in which complete bone contact without lucency was observed. If lucency was observed no points were attributed to the section. A fully osteointegrated cup in all 24 sections could therefore attain 600 points. The total of each section and zone was subsequently tallied and recalculated to produce the percentage of bone contact on a 1–100% score. Results. In 2011 131 patients; 54 male and 76 female with average age of 60.83 (SD 12.42) and 60.57 (SD 12.11) year respectively underwent primary THA at our institution and all where included in our study cohort. Majority of this cohort underwent primary THA due to osteoarthrosis and most patients were classified ASO I (18%) or ASA II (65%). At two year clinical follow-up two revision were performed. One constituted a femur and acetabulum revision due to leg length difference and a snapping hip phenomenon. Complications included 3 dislocations (all treated policlinic), 4 deep infections (all treated with Genta PMMA beads with prosthesis in situ and healed) and 1 removal of hematoma. In another patient the femoral component was revised due to a
The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture. Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem. Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.