Medium-term survivorship of the Oxford phase
3 unicompartmental knee replacement (UKR) has not yet been established
in an Asian population. We prospectively evaluated the outcome of
400
Introduction: The use of the
To identify frequency and patterns of
Objectives: The results of knee arthroplasty are commonly assessed by survival analysis using revision as the endpoint. We have used the assessment of pain by a patient based questionnaire as an alternative after the
To identify frequency and patterns of
Introduction: The introduction of the
This prospective study describes the outcome of the first 1000
Great interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has rapidly increased following the introduction of minimally invasive UKA (MI-UKA). This approach preserves the normal anatomy of knee, causes less damage to extensor mechanism and results in a more rapid post-operative recovery. However, experience with this approach is limited in China. The aim of this report was to determine the short-term clinical and radiographic outcomes of MI-UKA in the Chinese, and to identify any features that are unique to this population. Fifty two knees, in forty-eight patients, with medial compartmental osteoarthritis treated by MI-UKA via C-arm intensifier guide (CAIG) from May 2005 to January 2009 were reviewed. Pain and range of motion (ROM) was assessed using the HSS scoring system before and after surgery. Pre- and postoperative alignment of the lower limbs was measured and compared. The mean follow up time was 24 months (12-42 months). In all cases the pain over medial compartment of the knees was relieved or subsided. The post-operative ROM was 0-136 degree (mean 122degree), and the mean alignment was 2degree varus (0- 7degree varus). The HSS score increased from 72(61-82) to 92(72-95). 93% of the postoperative scores were good or excellent. Interestingly, the distribution of femoral component sizes of these patients was XS 2%, Small 83%, Medium 15%, Large 0%, XL 0%; whereas tibial component size was AA 27%, A 55%, B 15%, C 3%, D 0%, E 0%, and F 0%. The optimal fitted match between tibial and femoral size was: tibia AA and A with XS and small femur, tibia B and C with medium femur. The estimated match was: tibia D and E with large femur, tibia F with XL femur. In contrast to the Oxford report, the sizes of these components are smaller and not in correlation with the height, weight and BMI of the patients. We conclude that MI-UKA is an effective method for treating medial compartmental osteoarthritis of the knee in the Chinese population. CAIG is a feasibly intraoperative measure to predict femoral component sizes. However, component sizes and combinations are different from the Oxford guideline.
Intramedullary (IM) femoral alignment guide for unicondylar knee arthroplasty (UKA) is a classic and generally accepted technique to treat unicompartmental knee osteoarthritis. However, IM system has a risk of excessive blood loss, fat embolism and activation of coagulation.Moreover, the implant placement and limb alignment may be less accurate in IM for UKA than total knee arthroplasty. So we try to use extramedullary (EM) femoral alignment for UKA to avoid above disadvantages. To our knowledge, few current studies have been reported by now. We reported a series of cases treated through a newly developed EM technique and evaluated the accuracy of femoral component alignment and preliminary clinical results. Between January 2009 and January 2010, 11 consecutive patients(15 knees)consisting of 8 males and 3 females were enrolled. There were 7 cases in unilateral knee and 4 cases in bilateral knees. The mean age was 65.2 years (range 60∼72 years). Incision, surgical time, blood loss and complications were measured. The pre- and post operative function of the knees were evaluated by HSS score system. The pre- and postoperative femoral component alignment was measured and compared. All cases were followed up for average 15 months (10-22 months). The mean length of incision was 7.2cm (range 6 to 8cm), the mean surgical time was 115.0min(range 90 to 125min),the mean blood loss was 50.8ml (range 50 to 80ml). The mean preoperative HSS score increased from 75 (range 63 to 83) to 95 (range 88 to 97) postoperatively (p<0.05). All femoral components were within the recommended range for varus/valgus (±10 degree) and lexion/extension (±5 degree) angle. None had complications associated with reamed canal injury. By using our EM technique, we could achieve an accurate femoral component alignment and satisfactory clinical effect. However, strict comparison between EM and cconventional IM technique and large amount of cases are essential. Further mid- and long-term studies are required.
To identify the incidence and reasons for revision of the Oxford prosthesis (OXF) in New Zealand. Review and compare UKA and TKA data including patient-generated Oxford scores after operation.Purpose
Methods
The purpose of this study was to identify causes of failure and rates of revision of the Oxford prosthesis (OXF) in New Zealand, by reviewing and comparing the uni-compartmental (UKA) and total knee arthroplasty (TKA) data from January 2000 to December 2005, as recorded in the New Zealand National Joint Registry. Eighty one orthopaedic surgeons performed 2006 Oxford UKAs (64% of all UKAs). The revision rate was 4.7%. This compared with a revision rate of 4.8% for all UKAs combined, and 1.6% for TKA. UKA (3122) made up 13% of all knee arthroplasties (24 260). The most common reasons for revision of the OXF were aseptic loosening (45%), unexplained pain (33%) and bearing dislocation (12%). Unexplained pain as the only reason for revision (33%) was significantly different (p = 0.001) from the TKA rate (23%). Deep infection as a cause for revision was 0.20% for the OXF compared with 0.48% for TKA (p=0.07). The patient- generated Oxford scores at six months after operation were rated excellent or very good (Field et al, 2004) in 68% of OXF compared with 62% TKA patients (p = 0.001). Five higher-use OXF surgeons (12 or more/year) performed 25.1% of the operations with a revision rate of 0.99%. Ten high- use surgeons (eight to 11/year) performed 28.1 % of operations with a revision rate 4.6%. Thirty medium-use surgeons (two to seven/year) performed 39.0% of the operations with a revision rate of 6.4%. Thirty-six low-use surgeons (one or less/ year) performed 7.8% of the operations with a revision rate of 8.3%. The difference in revision rate between the higher-use surgeons (one operation/month) and all the other three lower use groups was significant (e.g. p=0.0006 higher/low) The early revision rate for the OXF was 2.9 times greater than that for TKA. However, higher-use surgeons (i.e. those performing one/month or more) had a revision rate comparable to TKA. Deep infection was lower and six month function scores were higher for OXF compared with TKA. Unexplained pain as the only reason for revision was significantly higher for OXF compared with TKA.
Background. In the United Kingdom (UK), the fastest growing population demographic is the over 85 years of age, but despite this, outcomes achieved in the octogenarian population with a Unicompartmental Knee Replacement (UKR) are underrepresented in the literature. The Elective Orthopaedic Centre, Epsom, has an established patient reported outcome measures (PROMs) programme into which all patients are routinely enrolled. We aim to investigate the outcome of medial UKR using the
Excessive under correction of varus deformity may lead to early failure and overcorrection may cause progressive degeneration of the lateral compartment following medial unicompartmental knee arthroplasty (UKA). However, what influences the postoperative limb alignment in UKA is still not clear. This study aimed to evaluate postoperative limb alignment in minimally-invasive Oxford medial UKAs and the influence of factors such as preoperative limb alignment, insert thickness, age, BMI, gender and surgeon's experience on postoperative limb alignment. Clinical and radiographic data of 122 consecutive minimally-invasive
Introduction. Unicompartmental knee arthroplasty (UKA) is a successful procedure for medial compartment osteoarthritis (OA). Recent studies using the same implant report a revision rate of 2.9%. Other centers have reported revision rates as high as 10.3%. The purpose of this study was to retrospectively review the clinical results of
Aims. Spontaneous osteonecrosis of the knee (SONK) mainly affects the medial femoral condyle, would be a good indication for UKA. The primary aim of this study was to assess the clinical, functional and radiographic outcomes at middle to long-term follow-up, of a consecutive series of fifty UKA used for the treatment of SONK. The secondary aim was to assess the volume of necrotic bone and determine if this influenced the outcome. Patients and Methods. We reviewed 50 knees who were treated for SONK. Patients included ten males and 38 females. The mean age was 73 years (range, 57 to 83 years). The mean height and body weight were, respectively 153 cm (141 ∼171 cm) and 57 kg (35 ∼75kg). All had been operated on using the Oxford mobile-bearing UKA (Zimmer-Biomet, Swindon, United Kingdom) with cement fixation. The mean follow-up period was 8.4 years (range, 4 to 15years). We measured the size (width, length and depth) and the volume to be estimated (width x length x depth) of the necrotic bone mass using MRI in T1-weighted images. The clinical results were evaluated using the Knee Society Scoring System (KSS) and Oxford Knee Score (OKS). The flexion angle of the knee was evaluated using lateral X-ray images in maximum flexion. Results. There were no implant failures, but there were 4 deaths (from causes unrelated to UKA) mean 6.6 years after surgery(5∼8), 3 cases were lost mean 3.3 years after surgery(2∼5). The mean size of the necrotic lesion were 17.2mm (14.7∼25.3) in width, 28.2mm (6.2∼38.3) in length and 11.3mm (3.2∼14.3) in depth. The mean volume of it was calculated to be approximate 5.4 cm. 3. (0.7∼11.1). The mean flexion of the knee, KSS Knee Score, Function Score and OKS increased from a preoperative 128.7 degrees (110 ∼ 140 degrees) to 137.5 degrees (110 ∼ 153 degrees), 52.3 (30 ∼ 64) to 91.3 (87 ∼ 100), 39.7 (15∼ 55) to 90.2 (65 ∼ 100) and 21.6 (12∼ 28) to 40.2 (34∼ 48), respectively at the latest follow-up. At last follow-up all patients had good or excellent OKS. Conclusions. There was a 100% survival rate of the
The aim of this study was to determine whether obesity had a detrimental effect on the long-term performance and survival of medial unicompartmental knee arthroplasties (UKAs). This study reviewed prospectively collected functional outcome scores and revision rates of all medial UKA patients with recorded BMI performed in Christchurch, New Zealand, from January 2011 to September 2021. Patient-reported outcome measures (PROMs) were the primary outcome of this study, with all-cause revision rate analyzed as a secondary outcome. PROMs were taken preoperatively, at six months, one year, five years, and ten years postoperatively. There were 873 patients who had functional scores recorded at five years and 164 patients had scores recorded at ten years. Further sub-group analysis was performed based on the patient’s BMI. Revision data were available through the New Zealand Joint Registry for 2,323 UKAs performed during this time period.Aims
Methods
Introduction. Patient Specific Instrumentation (PSI) has the potential to allow surgeons to perform procedures more accurately, at lower cost and faster than conventional instrumentation. However, studies using PSI have failed to convincingly demonstrate any of these benefits clinically. The influence of guide design on the accuracy of placement of PSI has received no attention within the literature. Our experience has suggested that surgeons gain greater benefit from PSI when undertaking procedures they are less familiar with. Lateral unicompartmental knee replacement (UKR) is relatively infrequently performed and may be an example of an operation for which PSI would be of benefit. We aimed to investigate the impact on accuracy of PSI with respect to the area of contact, the nature of the contact (smooth or studded guide surfaces) and the effect of increasing the number of contact points in different planes. Method. A standard anatomy tibial Sawbone was selected for use in the study and a computed tomography scan obtained to facilitate the production of PSI. Nylon PSI guides were printed on the basis of a lateral UKR plan devised by an orthopaedic surgeon. A control PSI guide with similar dimensions to the cutting block of the
Background. In this study, we investigated the long-term clinical results and survivorship of minimally invasive unicompartmental knee arthroplasty (UKA) by collecting cases that have been implanted for >10 years ago. Methods. Medial UKA on 180 cases in 142 patients was performed over a period of 1 year after the first introduction of minimally invasive UKA from January 2002 to December 2002. Among these, 166 cases in 128 patients who underwent
Aim: To assess the intra- and inter-observer reliability of using pre-operative templates in selecting the appropriate prosthetic size of the unicompartmental knee system (Oxford Phase3, Biomet Merck, Bridgend) Methods: Ten observers estimated the size of the unicondylar knee prosthesis required for thirty randomly selected patients with osteoarthritis. Estimation of the size was gauged using templates pre-operatively. AP and lateral radiographs were taken of each patient. All observers were orthopaedic surgeons with a minimum of þve years experience in orthopaedic surgery and with a general interest in joint arthroplasty. The observations were recorded independently and repeated measurements were taken two weeks later. Results: Intra- and inter-observer discrepancies were evaluated using the weighted kappa (κ) coefþcient with signiþcant intra- and inter-observer variations. The results are shown in the table. Conclusions: Pre-operative radiological templating is of questionable beneþt in patients undergoing