Advertisement for orthosearch.org.uk
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 47 - 47
1 Dec 2022
Sheridan G Clesham K Garbuz D Masri B
Full Access

The benefits of HXLPE in total knee arthroplasty (TKA) have not been as evident as total hip arthroplasty (THA). A systematic review and meta-analysis to assess the impact of highly-crosslinked polyethylene (HXLPE) on TKA outcomes compared to conventional polyethylene (CPE) is described. All studies comparing HXLPE with CPE for primary TKA were included for analysis. The minimum dataset included revision rates, indication for revision, aseptic component loosening and follow-up time. The primary outcome variables were all-cause revision, aseptic revision, revision for loosening, radiographic component loosening, osteolysis and incidence of radiolucent lines. Secondary outcome measures included postoperative functional knee scores. A random-effects meta-analysis allowing for all missing data was performed for all primary outcome variables. Six studies met the inclusion criteria. In total, there were 2,234 knees (1,105 HXLPE and 1,129 CPE). The combined mean follow-up for all studies was 6 years. The aseptic revision rate in the HXLPE group was 1.02% compared to 1.97% in the CPE group. There was no difference in the rate of all-cause revision (p = 0.131), aseptic revision (p = 0.298) or revision for component loosening (p = 0.206) between the two groups. Radiographic loosening (p = 0.200), radiolucent lines (p = 0.123) and osteolysis (p = 0.604) was similar between both groups. Functional outcomes were similar between groups. The use of HXLPE in TKA yields similar results for clinical and radiographic outcomes when compared to CPE at midterm follow-up. HXLPE does not confer the same advantages to TKA as seen in THA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 63 - 63
1 Apr 2018
Shon W Han S Lee D Kim H
Full Access

Background. Recent clinical studies have suggested that systemic metal ion levels are significantly elevated at midterm follow-up after ceramic-on-metal (COM) bearing. However, it is not clear whether there is a correlation between patient- and surgical-related factors including the lifestyle and elevated levels of serum metal ions following COM total hip arthroplsty (THA). Material and Methods. Two hundred and one patients (234 hips) including 121 COM patients (140 hips) and 80 non-COM patients (94 hips) were enrolled in accordance with the inclusion criteria. The patients were divided into three groups based on the type of surgical bearings used. The Harris Hip Score (HHS), University of California, Los Angeles (UCLA) activity scale score, and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score were measured, and radiographs were obtained for the analysis. Serum metal ion levels of cobalt and chromium were measured using a high-resolution inductively coupled plasma mass spectrometry. Patient- and surgical-related factors were analyzed to determine which group of patients is at a high risk of metal ion-related problems. Results. Significantly higher serum levels of Co and Cr were detected in the serum of the COM THA group (Co: 1.86±4.0 µg/L, range: 0.30 to 34.20 µg/L; Cr: 1.81±2.87 µg/L, range: 0.10 to 27.80 µg/L) than in the serum of the non-COM THA group (Co: 0.27±0.14 µg/L, range: 0.15 to 0.90 µg/L; Cr: 0.19±0.25 µg/L, range; 0.10 to 2.30 µg/L) (p<0.001). The HHS in the COM group was significantly better than that in the non-COM group (p=0.013). The total ROM of the THAs was significantly greater in the 36-mm COM THA group (272.7°, range: 200°–345°) than in the non-COM group (248.5°, range: 135°–300°) (p<0.001). No radiolucency, osteolysis, or loosening was found during the follow-up radiographic examination. The serum Co levels of patients who achieved the squatting position were significantly higher than those of patients who could not squat (Co: p=0.033; Cr: p=0.074). The serum Co and Cr levels of patients who achieved the kneeling position were significantly higher than those of patients who could not kneel (Co: p=0.049; Cr: p=0.031). There was no significant difference between the two groups in the cross-legged sitting position. The metal ion levels of the COM THA group correlated with the total ROM (Co: p=0.0293; Cr: p=0.0399), and those of the patients who were capable of squatting and kneeling were significantly higher than those of the patients who were unable (p<0.05). However, age, BMI, acetabular cup position and patient activity did not show significant correlations with the serum metal ion levels. Conclusions. Patients who underwent a 36-mm COM THA had good clinical outcomes with an excellent hip function at the short and midterm follow-up intervals. However, high levels of metal ions were detected in the serum of COM THA patients. We found that COM THA patients who were capable of greater ROMs, squatting, and kneeling are at risk of metal ion-related problems


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 186 - 186
1 Mar 2013
Jassim S Patel S Wardle N Tahmassebi J Middleton R Shardlow D Stephen A Hutchinson J Haddad F
Full Access

Introduction. In Total Hip Arthroplasty (THA), polyethylene wear reduction is key to implant longevity. Oxidized Zirconium (OxZi) unites properties of a ceramic bearing surface and metal head, producing less wear in comparison to standard Cobalt-Chromium (CoCr) when articulating with Cross-linked polyethylene (XLPE) in vitro. This study investigates in vivo polyethylene (PE) wear, outcomes and complications for these two bearing couples in patients at 5 year follow-up. Methods. 400 patients undergoing THA across four institutions were prospectively randomised into three groups. Group I received a cobalt-chrome (CoCr) femoral head/ cross-linked polyethylene (XLPE) liner; Group II received an OxZi femoral head/ ultrahigh molecular weight polyethylene (UHMWPE) liner; Group III received an OxZi femoral head/XLPE liner. All bearing heads were 32 mm. Linear wear rate was calculated with Martell computer software. Functional outcome and complications were recorded. Results. At median follow-up of 3.7 years, implant survivorship was 98% across all groups with no difference in SF-36, WOMAC, pain score or complications (p > 0.05). After the first 12 months of creep, rate of linear wear over 3 years was 0.07 mm for Group I, 0.16 mm for Group II, and 0.03 mm/year for Group III. A significant difference was detected when using UHMWPE (p = 0.012) but not when using XLPE (P = 0.75). Conclusion. At midterm follow-up, an XLPE acetabular liner is more important in reducing wear than the femoral head bearing. There is a trend towards lower wear when coupling OxZi rather than CoCr with XLPE; further long-term analysis is recommended to observe this pattern


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 113 - 113
1 Mar 2013
Cho YJ Lee J Chun YS Rhyu KH Kwak S Ji H Won YY Yoo M
Full Access

Purpose. To evaluate the radiological changes after metal on metal resurfacing arthroplasty. Materials and Methods. Between December 1998 and August 2004, 166 hips in 150 patients who underwent metal resurfacing arthroplasty and followed up more than 4 years. Their mean age at the time of operation was 37.3 years(range, 15–68 years) and mean period of follow-up was 6.1 years(range, 48–95 months). The cause of arthroplasty included 115 avascular necrosis, 43 osteoarthritis, 7 ankylosing spondylitis, 1 haemophilic arthropathy. All patients had anteroposterior, translateral radiographs of the hip made preoperatively and each follow-up visit, and we analyzed radiographic findings such as radiolucencies or impingement signs around implant, neck narrowing and heterotopic ossification. Results. There was a no significant difference between preoperative and postoperative Harris hip score and range of motion. The mean stem-shaft angle was 137.4°, and 55.4% were ranged 130° to 140°. The mean inclination of acetabular component was 44.9°. There were no radiolucent lines or osteolytic lesion around the acetabular components, but 3 hips showed radiolucency around the head-neck junction(1.8%) and 4 hips showed radiolucent line around the stem (2.4%). 12 hips had impingement signs around the head-neck junction (7.2%), and 2 cases showed neck narrowing (1.2%). 3 cases had some heterotopic ossification (1.8%). In 12 cases with impingement signs, the stem-shaft angle and inclination of acetabular component were lower than control group. Pseudotumor was not found in this cohort. Conclusions. This study demonstrates no serious radiological problems till the midterm follow-up after resurfacing arthroplasty, but osteolytic lesion such as radiolucent line around head-neck junction, neck narrowing can be a potential cause of failure in future. Even though the radiolucent line around stem of femoral component revealed no subjective symptom yet, it suggests the micromotion of femoral component which can lead to femoral component loosening. The most common radiological findings, impingement signs, seem not to have clinical significance


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 171 - 171
1 Sep 2012
Shen B Lai O Yang J Pei F
Full Access

Background and Objective. Total hip arthroplasty (THA) has been applied to treat pain and disability in patients with post-traumatic arthritis after acetabular fracture for many years. However, the midterm and long-term results of THA for this unique population are still controversial. According to previous studies, we found that uncemented acetabular reconstructions were usually performed in patients who were most likely to have the best results and an abnormal acetabular structure was usually the reason for THA failure. In this study, we evaluated the midterm results of using uncement acetabular components to treat posttraumatic arthritis after acetabular fracture. In addition, we investigated the effects of different acetabular fracture treatments and fracture patterns on THA. Materials and Methods. Between January 2000 to December 2003, 34 uncemented acetabular reconstructions were performed in 34 patients for posttraumatic arthritis after acetabular fractures. Among them, 31 patients underwent complete clinical and radiographic follow-up for an average of 6.3 years (range, 3.1–8.4 years). There were 22 men and 9 women. The patients' average age was 51 ± 12 years (range, 27–74 years) at the time of arthroplasty. The average interval from fracture to THA was 5.58 ± 4.42 years (range, 0.75–17.5 years). Of the 31 patients, 19 had undergone ORIF (open-reduction group) and 12 had received conservative treatment for the acetabular fractures (conservative-treatment group). Then, 14 had simple pattern fractures (simple group) and 17 had complex pattern fractures (complex group). After midterm follow-up, the radiographic and clinic results of the different groups were compared. Results. During 6.3 years' follow up, no infection occurred and no revision was needed in the 31 patients. In the open-reduction and conservative-treatment groups, the respective averages for duration of surgery, intraoperative blood loss, and amount of blood transfused were 138 ± 29 minutes and 98 ± 16 minutes (P < .001), 726 ± 288 mL and 525 ± 101 mL (P = .01), and 1,130 ± 437 mL and 1,016 ± 422 mL (P = .62). In the complex group and the simple group, the respective averages for duration of surgery, intraoperative blood loss, and amount of blood transfused were 132 ± 28 minutes and 109 ± 31 minutes (P = .042), 741 ± 221 mL and 536 ± 248 mL (P = .02), and 1,100 ± 414 mL and 1,075 ± 456 mL (P = .91). The average Harris Hip Score increased from 49 ± 15 before surgery to 89 ± 5 in the latest follow up, and 29 patients (94%) had either excellent or good results. The average Harris Hip Score for the open-reduction group and the conservative-treatment group increased to 87 ± 6 and 91 ± 3 (P = .07), respectively, after surgery; for the complex group and the simple group, it increased to 88 ± 6 and 90 ± 4 (P = .25), respectively. There was no significant difference between the open-reduction group and the conservative-treatment group or between the complex group and the simple group regarding the number of hips with excellent and good results. Of our 31 patients, none had a change in acetabular component abduction of >4°. The average horizontal migration of cup was 1.48 ± 0.46 mm (range, 0.7–2.33 mm), and the average vertical migration was 1.41 ± 0.54 mm (range, 0.5–2.51 mm). The average rate of polyethylene liner wear was 0.25 ± 0.11 mm/y (range, 0.03–0.41 mm/y). Average wear rates were 0.25 ± 0.12 mm/y and 0.24 ± 0.11 mm/y for the open-reduction group and the conservative-treatment group (P = .72), respectively, and 0.24 ± 0.13 mm/y and 0.26 ± 0.10 mm/y in the complex group and the simple group (P = .67), respectively. The average rate of polyethylene wear for all patients was positively related to BMI (r = .36; P = .047). After THA, all 31 patients had a reconstructed hip center within 20 mm of vertical and horizontal symmetry compared with the contralateral hip, including 27 patients (87%) with anatomic restoration and 4 patients with reconstructed hip center between 10–20 mm of vertical and horizontal symmetry. Anatomic restoration was positively related to fracture treatment (r = .48; P = .006), but it had no relation to fracture pattern (r = .16; P = .40). Conclusion. Uncement acetabular reconstruction following acetabular fracture had favorable midterm results. Fracture treatments and patterns are associated with increased operative time and hemorrhage amount. Open reduction and internal fixation of fracture favours anatomic restoration of hip rotational center