This study reports the mid-term results of a large bearing uncemented
This study reports the mid-term results of a large bearing hybrid
This study reports the mid-term results of a large bearing hybrid
The biological pathways responsible for adverse reactions to metal debris (ARMD) are unknown. Necrotic and inflammatory changes in response to Co-Cr nanoparticles in periprosthetic tissues may involve both a cytotoxic response and a type IV delayed hypersensitivity response. Our aim was to establish whether differences in biological cascade activation exists in tissues of patients with end-stage OA compared to those with aseptic loosening of a metal on polyethylene (MoP) THR and those with ARMD from metal-on-metal (MoM) THR. A microarray experiment (Illumina HT12-v4) was performed to identify the range of differential gene expression between 24 patients across 3 phenotypes: Primary OA (n=8), revision for aseptic loosening of MoP THR (n=8) and ARMD associated with MoM THR (n=8). Results were validated using Taqman Low Density Array (TLDA) selecting the top 36 genes in terms of fold-change (FC)>2 and a significant difference (p<0.05) on ANOVA. Pathways of cellular interaction were explored using Ingenuity IPA software.Introduction
Patients & Methods
Fracture of the acetabulum can lead to degenerative arthritis of the hip, avascular necrosis of the femoral head, or both. Total hip arthroplasty is a common form of surgical treatment when significant joint changes and pain are present. Ten patients with fracture acetabulum were treated in this study using metal on metal total hip arthoplasty. The initial fracture was posterior wall fracture in one patient, posterior column fracture in one patient, transverse fracture in 2 patients, fracture dislocation in 3 patients and fracture posterior wall and column in 3 patients. The indications of arthroplasty were secondry osteoarthritis after internal fixation or after conservative management or collapse of the femoral head. Arthroplasty was done after an average period of 1.8 years (range from 1 to 4 years). After a follow up period ranged from 3 to 7 years with a mean of 4.6 years, the Harris hip score was improved from a mean of 51 (range 20 to 65) to a mean of 92.5 (range 90 to 95). Infection occurred in one case and two stages revision was done. Another case developed loosening of the acetabular component and was revised using cementless cup fixed with screws and bone graft. Metal on metal THR after acetabular fracture are relatively uncomplicated and lead to a good outcome despite the difficulties faced during the procedure.
One hundred fifty one total hip arthroplasty (THA) with metal on metal hip system of without cement were followed at a mean of 5. 5 years (range 2. 6 years to 7 years). Original diseases were 134 hip in 123 cases with osteoarthritis and 17 hips in 13 with rheumatoid arthritis. The average Harris hip score of before the operation was 45. 3 points and at the follow-up time the average score was 88. 5 points. Radiographic findings in the incidence of partial radiolucent line around the component: in the acetabular component, no radiolucent line was observed, in the femoral component, marginal lucent lines were 8. 6% (13 hips). Cortical hypertrophy was observed in high ratio of 27. 2%(41 hips). There was no loosening and tilt of component over 5 degrees observed in any patient. Postoperative dislocation of the hip was observed 9 hips (6. 0%). Cobalt concentrations and chromium concentration in the serum were measured in cases in metal on metal total hip, metal on poly arthroplasty and in controls without implants. Serum was assayed using graphite furnaces atomic absorption spectrophotometer. No patients were seen of elevation in serum cobalt and chromium concentrations. The authors conclude that THA with metal on metal system has presented excellent results for mid term follow-up in our hospital.
The risk of dislocation in large diameter metal on metal hip replacement is significantly lower than in standard THR. This is due to the increased primary arc, increased jump distance and possibly a suction effect. Our unit has performed over 1500 of these cases with an overall revision rate of <1%. We report a case series of dislocations in 5 large diameter metal on metal hips undertaken at our unit. All cases were reduced closed and investigated for cause of dislocation. Radiological investigation included plain film radiographs and CT to exclude component mal-position and MRI to document soft tissue deficiency. Metal ion levels were measured and microbiological investigation was undertaken.INTRODUCTION
METHOD
We conducted independent wear analysis of retrieved metal on metal (MoM) hip components from around the world. All patients with resurfaced hips who developed adverse reactions to metal debris (ARMD) were found to have increased wear of the bearing surfaces. This was untrue in patients with large diameter (?36mm) MoM total hip replacements. This led us to search for other factors leading to ARMD. MoM THR explants retrieved from 78 patients suffering ARMD underwent full volumetric wear analysis of bearing surface and taper-junctions using coordinate measuring machine. Scanning electron microscopy (SEM) used to characterise material composition of specific areas.Introduction
Methods
Co and Cr concentrations were measured in both the seminal plasma and in the blood of patients by inductively coupled plasma-mass spectroscopy (ICP-MS).
In vitro the introduction of microseparation and edge loading to hip simulator gait cycle has replicated clinically relevant wear rates and wear mechanisms in ceramic-on-ceramic bearings[1], and elevated the wear rates of MoM surface replacements (SR) to levels similar to those observed in retrievals[2]. The aim was to assess the wear of two different sized MoM total hip replacement bearings under steep cup inclination angles and adverse microseparation and edge loading conditions. Two tests were performed on the Leeds II hip joint simulator using two different size bearings (28mm and 36mm). Cups were mounted to provide inclination angles of 45 degrees (n=3) and 65 degrees (n=3). The first three million cycles were under standard gait conditions. Microseparation and edge loading conditions as described by Nevelos et al[1] were introduced to the gait cycle for the subsequent three million cycles. The lubricant was 25% new born calf serum. The mean wear rates and 95% confidence limits were determined and statistical analysis was performed using One Way ANOVA. Under standard gait conditions, when the cup inclination angle increased from 45 degrees to 65 degrees, the wear of size 28mm bearing significantly (p=0.004) increased by 2.7-fold, however, the larger bearings did not show any increase in wear (p=0.9). The introduction of microseparation conditions resulted in a significant (p=0.0001) increase in wear rates for both bearing sizes under both cup inclination angle conditions. Under microseparation conditions, the increase in cup inclination angle had no influence on the wear rate for both bearing sizes (Figure 1). With larger bearings, head-rim contact occurs at a steeper cup inclination angle providing an advantage over smaller bearings. The introduction of edge loading and microseparation conditions resulted in a significant increase in wear rates for both bearing sizes. The wear rates obtained in this study under combined increased cup inclination angle and microseparation were half of those obtained when SR MoM bearings were tested under similar adverse conditions[2]. This study shows the importance of prosthesis design and accurate surgical positioning of the head and acetabular cup in MoM THRs.
In a cross sectional cohort study three different metal on metal total hip systems were assessed. Two monoblock acetabular designs; the Durom socket (Zimmer, Warsaw, In) and the Birmingham socket (Smith and Nephew, Memphis, TN), and one modular metal on metal total hip system (Pinnacle, Depuy Orthopaedics, Warsaw, In) in patients who have received these implants in the our region. 56 patients were recruited in total. All patients were assessed clinically, radiologically and biochemically. Whole blood Cobalt, Chromium and titanium levels were tested. The median head size used in the Birmingham group was 52mm (Range 44mm to 56mm), and in the Durom group, 48mm (Range 42 to 54mm). The median head size used in the modular Pinnacle group was 40mm (Range 36–44mm). The blood metal ions levels in the larger non modular acetabular sockets were significantly raised compared to the Pinnacle group. For Co 1.95 µg/l and 2.70 µg/l in the Durom and Birmingham groups respectively compared to only 0.52 µg/l in the Pinnacle group (P< 0.001). Mean Cr levels were the same for the two monoblock systems, 1.9 µg/l compared to the Pinnacle sockets 1.2 µg/l (P< 0.001). Our study clearly demonstrates that there is a significant difference in metal ion levels in patients following a monobloc large head arthroplasty system compared to a smaller modular metal on metal hip arthroplasty. The smaller head size appears to produce less metal ions whilst at the same time a 36mm–44mm head size is large enough to increase hip stability and range of movement as well as decreasing the risk of impingement. In our practice we are no longer using this design and the safest strategy, when considering metal on metal bearings, is to use a modular, smaller head system such as the Pinnacle.
Revision surgery for failed metal-on-metal (MOM) total hip arthroplasty (THA) or hip resurfacing (HR) has been a challenge. Previous studies have reported high failure and complication rates, including dislocation, infection, aseptic loosening and lower patient satisfaction. Options for revision depend on the integrity and stability of the femoral and acetabular components. When both components fail, full revision is required; however, when the acetabular component remains well fixed and oriented, only the isolated femoral component revision can be performed. Dual mobility components can be utilized to match the size to the inner diameter of the metal cup. With the dual mobility implant, the morbidity and complications associated with cup revision are avoided while maintaining a natural femoral head size and potentially increasing range of motion and stability postoperatively compared to standard THA. The aim of this study was to evaluate short- to mid-term results of revision THA after failed metal-on-metal THA or HR using the dual mobility device.Background
Purpose
An increase in metal ion levels is seen after implantation of all MoM hip prosthesis due to release from the surface directly, more so during articulation and corrosion of the bearing surfaces. The bearing surfaces in MoM prosthesis consist of cobalt, chromium and molybdenum. Several case-reports of cobalt toxicity due to a MoM prosthesis have been published in the last decade. Cobalt intoxication may lead to a variety of symptoms: neuro-ocular toxicity (tinnitus, vertigo, deafness, blindness, convulsions, headaches and peripheral neuropathy), cardiotoxicity and thyroid toxicity. Nausea, anorexia and unexplained weight loss have been described. Systemic effects from metal ions even with well functioning implants or with ion concentrations lower than those associated with known adverse effects may exist and warrant investigation. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head
Purpose of the study:. Recent literature raised concern on the adverse effects, incidence of pseudo tumours and raised blood and urine Chromium and Cobalt levels in patients with a metal on metal articulation. The purpose of this study was to follow up a cohort of patients that received a
The biological reaction in metallosis and pseudotumor generation after
Adverse reaction to metal debris (ARMD) is well recognised as a complication of large head
Background. Large head