Abstract

Metal on metal total hip arthroplasty (MoM THA) provides the potential improvement in articular wear. However, several adverse events including pseudotumor had been reported. Magnetic resonance imaging (MRI) was considered to be the proposal tool for detection of pseudotumor after MoM THA. In this study, we performed the screening of pseudotumor after MoM THA using the MRI.

We studied 43 patients with M2a Magnum® (Biomet) and 34 patients with M2a Taper® (Biomet) of MoM THA from December 2009 to December 2011 with follow-up of 2.5 years (2.0–4.0 years) after surgery. MRI assessments were performed at a mean of 2.1 years postoperatively. Pseudotumor findings were graded using Anderson classification (Skeletal Radiol, 2011: 40; 303). Age, sex, height, weight, Harris Hip Score, EQ5D satisfaction score, UCLA activity score, and blood metal ion levels were evaluated.

The prevalence of pseudotumor was 27.2%; 56 normal (Type A), 13 mild (C1), 8 moderate (C2) and none were graded severe (C3). Weight and BMI in the mild group was significantly higher than those in normal. There was no significant difference in age, sex and height among these groups. With regard to Harris Hip score, pain and ROM score in moderate group was significantly lower than that in normal and mild group. EQ5D satisfaction score and UCLA activity score showed not significant differences among groups. 3.01±3.32 μg/L of blood cobalt ion levels in the moderate groups was significantly higher than 0.97±0.64 μg/L in normal group. Blood cobalt ion levels of 1 mild and 2 moderate were over the threshold of 7 μg/L. These patients were implanted with M2a Taper, not M2a Magnum. 14% of the prevalence in the patients with M2a Magnum was significantly lower than 41% in the patients with M2a Taper. No revision surgeries were required.

The patients with no pseudotumor did not show the increase of blood metal ion. Contrarily, several patients showed the increase of blood metal ion in case of detecting pseudotumor. MRI assessments were useful for screening of pseudotumor after MoM THA and blood metal ion should be investigated for patients with mild and moderate pseudotumor in MoM THA.