The radiological and MRI appearances of 24 knees with patellar tendonitis resistant to conservative therapy were analysed to identify the characteristic MRI appearance and to determine if the patellar morphology was abnormal. A significant thickening of the tendon was found in all cases; this was a more reliable diagnostic feature than a high signal within the superior posterior and central aspect of the tendon at its proximal attachment The site of the lesion shown by MRI is more compatible with impingement of the inferior pole of the patella against the patellar tendon than a stress overload of the tendon. There were no significant differences in the length of the patella, inferior pole or length of the articular surface when the patellar morphology was compared with that of a matched control group.
The purpose of this study was to determine the accuracy of MRI scan for the detection of meniscal pathology in our unit. There are published data which show that both sensitivity and specificity can approach 90% when compared to arthroscopic findings. We retrospectively analysed a single surgeon series of 240 scopes for all indications The arthroscopic reports included an outline diagram of the meniscus upon which the surgeon recorded operative findings. 112 of these patients had also had recent MRI. We looked at whether the MRI report showed a tear, and this was graded Y/N. The arthroscopic report was graded for tear: Y/N. 66 patients had a positive scan. 64 of these were found to have a tear at surgery. 37 scans were reported as “no tear”, of which 4 were found to have a tear at surgery. Nine scans were not easy to classify as they were descriptive. In our series of 112 knees, MRI was 90.5% sensitive, 89.5% specific and 90.1% accurate. When a definite diagnosis of “tear”, or “no tear” was made at scan, there were two false positives and four false negatives. False positives may be unnecessarily exposed to the risks of surgery. Patients with negative scans had a mean delay to surgery of 33 weeks compared to 18 weeks for patients with positive scans. False negatives may wait longer for their surgery. Two of the false negative scans clearly showed meniscus tears which were missed by the reporting radiographer. In our series the scan itself was more accurate than the reporting. It is important to have an experienced musculoskeletal radiologist to minimise the number of missed tears. It is also important for surgeon to check the scan as well as the report.
A feasibility study of the use of an MRI based patient specific knee arthroplasty system within the NHS. Introducing new technologies within a public funded health system can be challenging. We assess the use and potential benefit of customised jigs for knee arthroplasty. Outcomes assessed were safety and accuracy of implantation. Eight knee replacements using custom jigs were compared to 11 conventionally instrumented replacements matched to surgeon and operative day. Parameters measured include tourniquet time; drain output; hospital stay; adjusted change in haemoglobin; complications; and component position on post-operative long-leg alignment films None of the parameters observed demonstrated a statistically significant difference from the conventional arthroplasty group. No complications were seen in either group. No significant differences were seen in alignment. Our early experiences show that this technology appears safe and allows accurate implantation of the prosthesis. There was a trend for decreased stay and blood loss. The health economic benefits of navigational arthroplasty have been demonstrated in other studies and come from the lack of instrumentation of the intramedullary canal. MRI based patient specific instrumentation is considered technically easier and more convenient than intra-operative navigation. A larger study is planned to assess the health economic implications of adopting this new technology.
Abstract. Introduction. Previous research has demonstrated no clinically significant benefit of arthroscopic meniscectomy in patients with a meniscal tear, however, patients included in these studies would not meet current treatment recommendations. Prior to further randomised controlled trials (RCTs) research is needed to understand a younger population in more detail. Aim. To describe the baseline characteristics of patients with a meniscal tear and explore any association between baseline characteristics and outcome. Methodology. A prospective, national multicentre cohort study was performed recruiting patients aged 18 to 55 presenting to secondary care. MRI analysis of arthritis was performed using Whole Organ
Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury. A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm2) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations.Aims
Methods
Objective patellar instability has been correlated with dysplasia of the femoral trochlea. This in vitro study tested the hypothesis that trochleoplasty would increase patellar stability and normalise the kinematics of a knee with a dysplastic trochlea. Six fresh-frozen knees were loaded via the heads of the quadriceps. The patella was displaced 10 mm laterally and the displacing force was measured from 0° to 90° of flexion. Patellar tracking was measured from 0° to 130° of knee flexion using
The treatment of osteochondral lesions is of
great interest to orthopaedic surgeons because most lesions do not heal
spontaneously. We present the short-term clinical outcome and MRI
findings of a cell-free scaffold used for the treatment of these
lesions in the knee. A total of 38 patients were prospectively evaluated
clinically for two years following treatment with an osteochondral
nanostructured biomimetic scaffold. There were 23 men and 15 women; the
mean age of the patients was 30.5 years (15 to 64). Clinical outcome
was assessed using the Knee Injury and Osteoarthritis Outcome Score
(KOOS), the Tegner activity scale and a Visual Analgue scale for
pain. MRI data were analysed based on the
Adenosine, lidocaine, and Mg2+ (ALM) therapy exerts differential immuno-inflammatory responses in males and females early after anterior cruciate ligament (ACL) reconstruction (ACLR). Our aim was to investigate sex-specific effects of ALM therapy on joint tissue repair and recovery 28 days after surgery. Male (n = 21) and female (n = 21) adult Sprague-Dawley rats were randomly divided into ALM or Saline control treatment groups. Three days after ACL rupture, animals underwent ACLR. An ALM or saline intravenous infusion was commenced prior to skin incision, and continued for one hour. An intra-articular bolus of ALM or saline was also administered prior to skin closure. Animals were monitored to 28 days, and joint function, pain, inflammatory markers, histopathology, and tissue repair markers were assessed.Aims
Methods
Patient specific cutting guides generated by
preoperative
Tourniquets have potential adverse effects including postoperative thigh pain, likely caused by their ischaemic and possible compressive effects. The aims of this preliminary study were to determine if it is possible to directly measure intramuscular pH in human subjects over time, and to measure the intramuscular pH changes resulting from tourniquet ischaemia in patients undergoing knee arthroscopy. For patients undergoing short knee arthroscopic procedures, a sterile calibrated pH probe was inserted into the anterior fascial compartment of the leg after skin preparation, but before tourniquet inflation. The limb was elevated for three minutes prior to tourniquet inflation to 250 mmHg or 300 mmHg. Intramuscular pH was recorded at one-second intervals throughout the procedure and for 20 minutes following tourniquet deflation. Probe-related adverse events were recorded.Aims
Methods
This prospective study used magnetic resonance imaging to record sagittal plane tibiofemoral kinematics before and after anterior cruciate ligament reconstruction using autologous hamstring graft. Twenty patients with anterior cruciate ligament injuries, performed a closed-chain leg-press while relaxed and against a 150 N load. The tibiofemoral contact patterns between 0° to 90° of knee flexion were recorded by
The Oswestry-Bristol Classification (OBC) was recently described as an MRI-based classification tool for the femoral trochlear. The authors demonstrated better inter- and intraobserver agreement compared to the Dejour classification. As the OBC could potentially provide a very useful MRI-based grading system for trochlear dysplasia, it was the aim to determine the inter- and intraobserver reliability of the classification system from the perspective of the non-founder. Two orthopaedic surgeons independently assessed 50 MRI scans for trochlear dysplasia and classified each according to the OBC. Both observers repeated the assessments after six weeks. The inter- and intraobserver agreement was determined using Cohen’s kappa statistic and S-statistic nominal and linear weights.Aims
Methods
Stiffness is a common complication after total knee arthroplasty (TKA). Pathogenesis is not understood, treatment options are limited, and diagnosis is challenging. The aim of this study was to investigate if MRI can be used to visualize intra-articular scarring in patients with stiff, painful knee arthroplasties. Well-functioning primary TKAs (n = 11), failed non-fibrotic TKAs (n = 5), and patients with a clinical diagnosis of fibrosisAims
Methods
We propose a state-of-the-art temporary spacer, consisting of a cobalt-chrome (CoCr) femoral component and a gentamicin-eluting ultra-high molecular weight polyethylene (UHMWPE) tibial insert, which can provide therapeutic delivery of gentamicin, while retaining excellent mechanical properties. The proposed implant is designed to replace conventional spacers made from bone cement. Gentamicin-loaded UHMWPE was prepared using phase-separated compression moulding, and its drug elution kinetics, antibacterial, mechanical, and wear properties were compared with those of conventional gentamicin-loaded bone cement.Aims
Methods
Primary (or spontaneous) and secondary osteonecrosis of the knee
can lead to severe joint degeneration, for which either total or
unicompartmental arthroplasty may be considered. However, there
are limited studies analyzing outcomes of unicompartmental knee arthroplasties
(UKAs) for osteonecrosis involving an isolated compartment of the
knee. The aims of this study were to analyze outcomes of UKAs for
osteonecrosis with specific focus on 1) survivorship free of any
revision or reoperation, 2) risk factors for failure, 3) clinical outcomes,
and 4) complications. A total of 45 patients underwent 46 UKAs for knee osteonecrosis
between 2002 and 2014 at our institution (The Mayo Clinic, Rochester,
Minnesota). Twenty patients (44%) were female; the mean age of the
patients was 66 years, and mean body mass index (BMI) was 31 kg/m2. Of
the 46 UKAs, 44 (96%) were medial UKAs, and 35 (76%) were fixed-bearing
design. Mean mechanical axis postoperatively was 1.5° varus (0°
to 5° varus); 41 UKAs (89%) were performed for primary osteonecrosis.
Mean follow-up was five years (2 to 12)Aims
Patients and Methods