Introduction. In 2011 the Scottish Government published national
Objectives. Vancomycin and fosfomycin are antibiotics commonly used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the in vitro inhibitory effects against
To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Twenty tissue samples infected with either MSSA (n = 10) or
Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and
Infection in orthopedics is a challenge, since it has high incidence (rates can be up to 15-20%, also depending on the surgical procedure and on comorbidities), interferes with osseointegration and brings severe complications to the patients and high societal burden. In particular, infection rates are high in oncologic surgery, when biomedical devices are used to fill bone gaps created to remove tumors. To increase osseointegration, calcium phosphates coatings are used. To prevent infection, metal- and mainly silver-based coatings are the most diffused option. However, traditional techniques present some drawbacks, including scarce adhesion to the substrate, detachments, and/or poor control over metal ions release, all leading to cytotoxicity and/or interfering with osteointegration. Since important cross-relations exist among infection, osseointegration and tumors, solutions capable of addressing all would be a breakthrough innovation in the field and could improve clinical practice. Here, for the first time, we propose the use antimicrobial silver-based nanostructured thin films to simultaneously discourage infection and bone metastases. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture. These characteristics, in turn, allow tuning silver release and avoid delamination, thus preventing toxicity. In addition, to mitigate interference with osseointegration, here silver composites with bone apatite are explored. Indeed, capability of bone apatite coatings to promote osseointegration had been previously demonstrated in vitro and in vivo. Here, antibacterial efficacy and biocompatibility of silver-based films are tested in vitro and in vivo. Finally, for the first time, a proof-of-concept of antitumor efficacy of the silver-based films is shown in vitro. Coatings are obtained by silver and silver-bone apatite composite targets. Both standard and custom-made (porous) vertebral titanium alloy prostheses are used as substrates. Films composition and morphology depending on the deposition parameters are investigated and optimized. Antibacterial efficacy of silver films is tested in vitro against gram+ and gram- species (E. coli, P. aeruginosa, S. aureus, E. faecalis), to determine the optimal coatings characteristics, by assessing reduction of bacterial viability, adhesion to substrate and biofilm formation. Biocompatibility is tested in vitro on fibroblasts and MSCs and, in vivo on rat models. Efficacy is also tested in an in vivo rabbit model, using a multidrug resistant strain of S. aureus (MRSA, S. aureus USA 300). Absence of nanotoxicity is assessed in vivo by measuring possible presence of Ag in the blood or in target organs (ICP-MS). Then, possible antitumor effect of the films is preliminary assessed in vitro using MDA-MB-231 cells, live/dead assay and scanning electron microscopy (FEG-SEM). Statistical analysis is performed and data are reported as Mean ± standard Deviation at a significance level of p <0.05. Silver and silver-bone apatite films show high efficacy in vitro against all the tested strains (complete inhibition of planktonic growth, reduction of biofilm formation > 50%), without causing cytotoxicity. Biocompatibility is also confirmed in vivo. In vivo, Ag and Ag-bone apatite films can inhibit the
Background. North America is facing a rising epidemic involving strains of methicillin-resistant Staphylococcus aureus (MRSA) that, instead of being found almost exclusively in hospitals, are community-associated (CA-MRSA). These strains are aggressive, associated with musculoskeletal manifestations including osteomyelitis (OM), and septic arthritis (SA). We aimed to establish novel management algorithms for acute OM and SA in children. We investigated S.aureus susceptibilities to current first-line antimicrobials to determine their local efficacy. Methods. The project was conducted at Nemours Children Hospital in Florida, USA, following approval by the internal review board. A literature review was conducted. An audit of S.aureus antimicrobial sensitivities was completed over three years and compared against national standards. Susceptibilities of clindamycin, trimethoprim/sulfamethoxazole (TMP/SMX) and vancomycin were studied using local resistance ranges. Results. Two algorithms for acute OM and SA management were created adopting a multidisciplinary team approach from admission to discharge whilst differentiating higher risk patients within fast-track pathways. We analysed 532 microbiology results for antibiotic susceptibilities from 2012 to 2014. Overall, 51% of S.aureus infections were
Introduction. Carriers of Staphylococcus aureus, both methicillin sensitive (MSSA) and methicillin resistant (MRSA), have an increased risk for health-care associated infections. Despite WHO recommendations there is currently no national screening and eradication policy for the detection of MSSA in the UK or USA. This study aimed to evaluate the effectiveness of current standard
In this study we aimed to identify which anatomical site was the most effective for methicillin resistant staphylococcus aureus (MRSA) detection within an elective orthopaedic setting. A retrospective review was performed of 13,373 elective orthopaedic patients from pre-assessment and admission screening swabs taken over a five year period (2005-2010). Swabs were taken from the nose, the axilla and either the groin or perineum.
The implementation of knee arthrodesis has become synonymous with limb salvage in the presence of chronic sepsis and bone loss around the knee. This can be seen in failed trauma surgery or knee arthroplasty as an alternative to trans-femoral amputation. There is no prior literature assessing which factors affect knee arthrodesis using external fixation devices. Sixteen consecutive patients (four women and twelve men) made up of eleven infected knee implants, three internal fixations of the tibial following fractured tibial plateau as well as 2 infected native joints were identified. The mean age at initial surgery was 56 years (range 25 to 82 years). All procedures were performed under the direct supervision of the limb reconstruction teams using a standard protocol with either a Taylor spatial frame or Ilizarov frame. The patient records, microbiology results and radiographs of all patients who underwent knee arthrodesis at this institution between 1999 and 2010 were reviewed. Of the 16 patients in this study knee fusion occurred in eleven patients (69%). The five patients where arthrodesis failed all had significant bone loss on the pre-operative radiographs and confirmed at surgery. We found a relationship between a significant infection of the knee with
Background and Aims. Daily senior review is of paramount importance to provide optimal clinical care and facilitate timely discharge. Also, the General Medical Council state in Good Medical Practice 2013 that “work should be recorded clearly, accurately and legibly…containing relevant clinical findings, decisions made and actions agreed”. This audit aims to evaluate whether all trauma and elective Orthopaedic patients at one unit receive a daily senior review, which is fully documented in the case-notes, and whether a Comprehensive Unit-based Safety Programme (CUSP) toolkit can better facilitate this?. Methods. Case-notes for all patients admitted under Trauma and Orthopaedics on three separate non-consecutive days during a two-week period were scrutinized, examining them for the presence of CUSP toolkits and whether these were adequately completed. Results. 71 case-notes containing 291 CUSP toolkits were analysed. 46.4% had a completed toolkit for everyday since admission; however for those that did not, over half (55.2%) did not have a senior review documented elsewhere for the missing days. Only 1.4% of case-notes had a full complement of up-to-date CUSP toolkits completed entirely correctly. For patients on Orthopaedic wards, most common errors were failure to document date and time (69.7% incorrect), ward and bed number (30.7% incorrect), patient alerts (70.7% incorrect) and overall compliance in documentation of required parameters such as
Late infection is the most frequent complications after hemiarthroplasty. Urinary tract infections are the only distant septic focus considered to be a risk factor in the literature. We retrospectively reviewed 460 patients with hip fracture treated by hemiarthroplasy over a period of one year. Preoperative positive urine dipsticks and urine analysis have been looked at as causes for delay of surgery in absence of clinical manifestations of urinary tract infection. 367 patients were operated within 24 hours. 78 patients were delayed more than 78 hours. Urinary tract infection had the least contribution as a cause of delay. 99 patients had preoperative urinary tract infection and 57 patients had postoperative wound infection. Of these with postoperative surgical site infection, 31 patients did not show any evidence of preoperative urinary tract infection, 23 patients had preoperative urinary tract infection, two had leg ulcer and one had chest infection. 13 patients had chronic urinary tract infection and five patients had the same causative organism in urine & wound. The most common organisms of urinary infection are E. Coli, mixed growth, Enteroccocus Faecalis, Pseudomonas and others. The most causative organism of the postoperative surgical site infection are Staph aureus including
Summary Statement. Combination of antibiotics with N-acetylcisteine and sub-MIC concentration of erythromycin was evaluated in two collection and 16 clinical strains of staphylococci isolated from PJI. The results were strain-dependent, so it evidences the necessity of perform individual studies of biofilm susceptibility. Objectives. Staphylococci are the most common cause of prosthetic joint infections (PJI) (1), making the treatment of this disease difficult due to the increased resistance to antibiotics of biofilms. Combination between antibiotics and other compounds could be a good alternative. The aim of this study was to evaluate the effect of the combination of two compounds with nine antibiotics in biofilms formed by staphylococcal strains isolated from PJI. Methods. 16 clinical strains (8 S. aureus and 8 S. epidermidis) isolated from patients with PJI as well as 2 collection strains (S. aureus 15981 and S. epidermidis ATCC 35984) were tested against 9 antibiotics (rifampin, vancomycin, tigecycline, clindamycin, cotrimoxazole, ciprofloxacin, cloxacillin, daptomycin and fosfomycin) in combination with NAC 1024 μg/mL and erythromycin at subinhibitory concentration (0.12 μg/mL), which was established after the determination of MIC according to EUCAST recommendations. The Calgary Biofilm Device (CBD) was used to determine the susceptibility of the biofilms to these combinations. The Minimal Biofilm Eradication Concentration (MBEC) for the all the antibiotics alone was determined in a previous study. All the experiments were performed by triplicate. Results. All the S. aureus strains showed homogeneous results, and the addition of NAC or erythromycin at the tested concentrations has not a clear effect in the antibiotic susceptibility of the biofilm, although combination of tigecycline with NAC seems even to increase the MBEC in most cases. Almost all clinical strains were
Introduction. Open fractures occur with an annual incidence of 11.5 per 100,000 (6900 pa in UK). Infection rates, even with intravenous broad-spectrum antibiotics, remain as high as 22%. For this reason necessary bone grafting is usually delayed until soft-tissue cover of the bone injury is achieved. A biodegradable bone graft that released sustained high concentrations of antibiotics and encouraged osteogenesis, that could be implanted safely on the day of injury would reduce infection rates and avoid reoperation and secondary grafting. The non –union rate (approx 350 pa in UK) should also be reduced. Such a graft, consisting of a PLA/PGA co –polymer and containing antibiotics, is under development and here we report assessment of spectrum and duration of antimicrobial activity and effect of addition of antibiotics on mechanical properties. Methods. Varying concentrations of gentamicin, colistin, clindamycin and trimethoprim, singly and in combination, were added to the copolymer and test pieces were made. These were then tested using an established method (SPTT) which determines degree and duration of antimicrobial activity as well as risk of emerging resistance. Test bacteria were Staphylococcus epidermidis, Staphylococcus aureus,
The objective of this study is to determine an optimal antibiotic-loaded
bone cement (ALBC) for infection prophylaxis in total joint arthroplasty
(TJA). We evaluated the antibacterial effects of polymethylmethacrylate
(PMMA) bone cements loaded with vancomycin, teicoplanin, ceftazidime,
imipenem, piperacillin, gentamicin, and tobramycin against methicillin-sensitive Objectives
Methods
The objective of this study was to compare the elution characteristics,
antimicrobial activity and mechanical properties of antibiotic-loaded
bone cement (ALBC) loaded with powdered antibiotic, powdered antibiotic
with inert filler (xylitol), or liquid antibiotic, particularly focusing
on vancomycin and amphotericin B. Cement specimens loaded with 2 g of vancomycin or amphotericin
B powder (powder group), 2 g of antibiotic powder and 2 g of xylitol
(xylitol group) or 12 ml of antibiotic solution containing 2 g of
antibiotic (liquid group) were tested.Objectives
Methods
To review the current best surgical practice and detail a multi-disciplinary
approach that could further reduce joint replacement infection. Review of relevant literature indexed in PubMed.Objectives
Methods
The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal. We compared the doubling time of coagulase negative staphylococcus, Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control. Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.
Platelet-rich plasma is a new inductive therapy which is being increasingly used for the treatment of the complications of bone healing, such as infection and nonunion. The activator for platelet-rich plasma is a mixture of thrombin and calcium chloride which produces a platelet-rich gel. We analysed the antibacterial effect of platelet-rich gel Zones of inhibition produced by platelet-rich gel ranged between 6 mm and 24 mm (mean 9.83 mm) in diameter. Platelet-rich gel inhibited the growth of
The treatment of chronic osteomyelitis often
includes surgical debridement and filling the resultant void with antibiotic-loaded
polymethylmethacrylate cement, bone grafts or bone substitutes.
Recently, the use of bioactive glass to treat bone defects in infections
has been reported in a limited series of patients. However, no direct comparison
between this biomaterial and antibiotic-loaded bone substitute has
been performed. In this retrospective study, we compared the safety and efficacy
of surgical debridement and local application of the bioactive glass
S53P4 in a series of 27 patients affected by chronic osteomyelitis
of the long bones (Group A) with two other series, treated respectively
with an antibiotic-loaded hydroxyapatite and calcium sulphate compound
(Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded
demineralised bone matrix (Group C; n = 22). Systemic antibiotics
were also used in all groups. After comparable periods of follow-up, the control of infection
was similar in the three groups. In particular, 25 out of 27 (92.6%)
patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out
of 22 (86.3%) in Group C showed no infection recurrence at means
of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up,
respectively, while Group A showed a reduced wound complication
rate. Our results show that patients treated with a bioactive glass
without local antibiotics achieved similar eradication of infection
and less drainage than those treated with two different antibiotic-loaded
calcium-based bone substitutes. Cite this article: