Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 12 - 12
1 Aug 2013
Fraser-Moodie J Visvanathan V Hilmi O
Full Access

Introduction. In 2011 the Scottish Government published national MRSA screening requirements. A comparison of Orthopaedic and ENT elective surgery intended to juxtapose a specialty known to take MRSA screening seriously with one that has little clinical concern with regards MRSA infection. ENT surgery parallels Orthopaedics in using implants and there potentially being MRSA colonisation at or close to the site of surgery. In Orthopaedics MRSA infection is infrequent, but implant infection with antibiotic resistant bacteria has a particularly poor prognosis. In ENT MRSA infection is rare and colonisation does not influence patient care. Aims. An evaluation of MRSA screening practice for elective Orthopaedics and ENT surgery at Gartnavel General Hospital with regards strategy and implementation. Method. Review of 342 consecutive elective ENT patients and 325 Orthopaedic patients attending for inpatient or day case surgery. The reference standards were the regional and national guidelines on MRSA screening. Results. Overall screening rates were 145 (42%) of 342 ENT patients and 270 (83%) of 326 Orthopaedic patients. 100% of Orthopaedic patients admitted (154) were screened, in compliance with both regional and national policy. 91 (70%) of 130 ENT patients admitted were screened for MRSA, and no risk assessment was carried out, which was not in compliance with either regional or national policy. Discussion. Orthopaedic surgery has an established and reliable practice of screening elective inpatient cases, and when identified MRSA colonisation results in a change in patient management. ENT surgery should have established a similar practice according to existing local guidelines. The Government consider ENT a lower risk speciality for MRSA, but still require as a minimum a documented MRSA risk assessment process


Bone & Joint Research
Vol. 6, Issue 3 | Pages 132 - 136
1 Mar 2017
Yuenyongviwat V Ingviya N Pathaburee P Tangtrakulwanich B

Objectives. Vancomycin and fosfomycin are antibiotics commonly used to treat methicillin-resistant Staphylococcus aureus (MRSA) infection. This study compares the in vitro inhibitory effects against MRSA of articulating cement spacers impregnated with either vancomycin or fosfomycin. Methods. Vancomycin-impregnated articulating cement spacers and fosfomycin-impregnated articulating cement spacers were immersed in sterile phosphate-buffered saline (PBS) solutions and then incubated. Samples were collected for bioactivity evaluation. The aliquots were tested for MRSA inhibition with the disc diffusion method, and the inhibition zone diameters were measured. The inhibition zone differences were evaluated using the Wilcoxon Rank Sum Test. Results. The vancomycin group had significantly larger inhibition zones than the fosfomycin group from day three through to completion of the fourth week of incubation (p < 0.001). The vancomycin group exhibited a MRSA inhibition zone up to four weeks but the fosfomycin group showed an inhibition zone for only three days and after that did not show the the potential to inhibit MRSA. Conclusion. This in vitro study found that the inhibitory effect of vancomycin-impregnated articulating cement spacers against MRSA outperformed fosfomycin-impregnated articulating cement spacers. Further comparing our results to other published reports suggests there might be a limitation of the disc diffusion bioassay to show a large inhibitory zone in a high concentration of a highly soluble antibiotic. Cite this article: V. Yuenyongviwat, N. Ingviya, P. Pathaburee, B. Tangtrakulwanich. Inhibitory effects of vancomycin and fosfomycin on methicillin-resistant Staphylococcus aureus from antibiotic-impregnated articulating cement spacers. Bone Joint Res 2017;6:132–136. DOI: 10.1302/2046-3758.63.2000639


Full Access

To date, few studies have investigated the feasibility of the loop-mediated isothermal amplification (LAMP) assay for identifying pathogens in tissue samples. This study aimed to investigate the feasibility of LAMP for the rapid detection of methicillin-susceptible or methicillin-resistant Staphylococcus aureus (MSSA or MRSA) in tissue samples, using a bead-beating DNA extraction method. Twenty tissue samples infected with either MSSA (n = 10) or MRSA (n = 10) were obtained from patients who underwent orthopedic surgery for suspected musculoskeletal infection between December 2019 and September 2020. DNA was extracted from the infected tissue samples using the bead-beating method. A multiplex LAMP assay was conducted to identify MSSA and MRSA infections. To recognize the Staphylococcus genus, S. aureus, and methicillin resistance, 3 sets of 6 primers for the 16S ribosomal ribonucleic acid (rRNA) and the femA and mecA genes were used, respectively. The limit of detection and sensitivity (detection rate) of the LAMP assay for diagnosing MSSA and MRSA infection were analyzed. The results of this study suggest that the LAMP assay performed with tissue DNA samples can be a useful diagnostic method for the rapid detection of musculoskeletal infections caused by MSSA and MRSA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 15 - 15
2 Jan 2024
Costa B Alves P Fonseca D Campos F Monteiro AC Pereira R Costa F Gomes P Martínez-de-Tejada G Monteiro C Martins M
Full Access

Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and MRSA, and in Muller- Hinton Broth (MHB), 50% (v/v) in PBS, supplemented with human plasma (1% (v/v)), for 6 and 24 h against MRSA. The obtained NorChit-Dhvar5 nanogels, presented a round-shaped and ∼100 nm. NorChit- Dhvar5 nanogels in a concentration of 10. 10. nanogels/mL in PBS were capable of reducing the initial inoculum of P. aeruginosa by 99%, S. aureus by 99%, and MRSA by 90%. These results were corroborated by a 99% MRSA reduction, after 24 h in medium. Furthermore, NorChit-Dhvar5 nanogels do not demonstrate signs of cytotoxicity against MC3T3-E1 cells (a pre-osteoblast cell line) after 14 days, having high potential to prevent antibiotic-resistant infection in the context of ODRIs


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2022
Graziani G Ghezzi D Sartori M Fini M Perut F Montesissa M Boi M Cappelletti M Sassoni E Di Pompo G Giusto E Avnet S Monopoli D Baldini N
Full Access

Infection in orthopedics is a challenge, since it has high incidence (rates can be up to 15-20%, also depending on the surgical procedure and on comorbidities), interferes with osseointegration and brings severe complications to the patients and high societal burden. In particular, infection rates are high in oncologic surgery, when biomedical devices are used to fill bone gaps created to remove tumors. To increase osseointegration, calcium phosphates coatings are used. To prevent infection, metal- and mainly silver-based coatings are the most diffused option. However, traditional techniques present some drawbacks, including scarce adhesion to the substrate, detachments, and/or poor control over metal ions release, all leading to cytotoxicity and/or interfering with osteointegration. Since important cross-relations exist among infection, osseointegration and tumors, solutions capable of addressing all would be a breakthrough innovation in the field and could improve clinical practice. Here, for the first time, we propose the use antimicrobial silver-based nanostructured thin films to simultaneously discourage infection and bone metastases. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture. These characteristics, in turn, allow tuning silver release and avoid delamination, thus preventing toxicity. In addition, to mitigate interference with osseointegration, here silver composites with bone apatite are explored. Indeed, capability of bone apatite coatings to promote osseointegration had been previously demonstrated in vitro and in vivo. Here, antibacterial efficacy and biocompatibility of silver-based films are tested in vitro and in vivo. Finally, for the first time, a proof-of-concept of antitumor efficacy of the silver-based films is shown in vitro. Coatings are obtained by silver and silver-bone apatite composite targets. Both standard and custom-made (porous) vertebral titanium alloy prostheses are used as substrates. Films composition and morphology depending on the deposition parameters are investigated and optimized. Antibacterial efficacy of silver films is tested in vitro against gram+ and gram- species (E. coli, P. aeruginosa, S. aureus, E. faecalis), to determine the optimal coatings characteristics, by assessing reduction of bacterial viability, adhesion to substrate and biofilm formation. Biocompatibility is tested in vitro on fibroblasts and MSCs and, in vivo on rat models. Efficacy is also tested in an in vivo rabbit model, using a multidrug resistant strain of S. aureus (MRSA, S. aureus USA 300). Absence of nanotoxicity is assessed in vivo by measuring possible presence of Ag in the blood or in target organs (ICP-MS). Then, possible antitumor effect of the films is preliminary assessed in vitro using MDA-MB-231 cells, live/dead assay and scanning electron microscopy (FEG-SEM). Statistical analysis is performed and data are reported as Mean ± standard Deviation at a significance level of p <0.05. Silver and silver-bone apatite films show high efficacy in vitro against all the tested strains (complete inhibition of planktonic growth, reduction of biofilm formation > 50%), without causing cytotoxicity. Biocompatibility is also confirmed in vivo. In vivo, Ag and Ag-bone apatite films can inhibit the MRSA strain (>99% and >86% reduction against ctr, respectively). Residual antibacterial activity is retained after explant (at 1 month). These studies indicate that IJD films are highly tunable and can be a promising route to overcome the main challenges in orthopedic prostheses


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 90 - 90
1 Apr 2017
Ezzat A Lovejoy J Alexander K
Full Access

Background. North America is facing a rising epidemic involving strains of methicillin-resistant Staphylococcus aureus (MRSA) that, instead of being found almost exclusively in hospitals, are community-associated (CA-MRSA). These strains are aggressive, associated with musculoskeletal manifestations including osteomyelitis (OM), and septic arthritis (SA). We aimed to establish novel management algorithms for acute OM and SA in children. We investigated S.aureus susceptibilities to current first-line antimicrobials to determine their local efficacy. Methods. The project was conducted at Nemours Children Hospital in Florida, USA, following approval by the internal review board. A literature review was conducted. An audit of S.aureus antimicrobial sensitivities was completed over three years and compared against national standards. Susceptibilities of clindamycin, trimethoprim/sulfamethoxazole (TMP/SMX) and vancomycin were studied using local resistance ranges. Results. Two algorithms for acute OM and SA management were created adopting a multidisciplinary team approach from admission to discharge whilst differentiating higher risk patients within fast-track pathways. We analysed 532 microbiology results for antibiotic susceptibilities from 2012 to 2014. Overall, 51% of S.aureus infections were MRSA versus 49% methicillin-susceptible S.aureus (MSSA). Surprisingly, clindamycin resistance rates rose compared to 2005 (MRSA 7% in 2005 vs 39% currently, MSSA 20% vs 31% and total S.aureus resistance rate of 8% vs 35%, respectively). MRSA and MSSA isolates were near 100% sensitive to Vancomycin and TMP/SMX. No appropriate national standards existed. Conclusions. Multidisciplinary based algorithms were created for acute OM and SA treatment in children. Possible therapeutic roles for ultrasound guided aspiration and corticosteroids were highlighted in SA. Our audit revealed equal incidence of MSSA to MRSA, supporting national figures on falling MRSA. Interestingly, incresed resistance of MSSA and MRSA was found towards recommended first line clindamycin, raising concern over its efficacy. Level of Evidence. 5


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 64 - 64
1 Apr 2018
Tsang J McHugh M Guerendiain D Gwynne P Boyd J Walsh T Laurenson I Templeton K Simpson H
Full Access

Introduction. Carriers of Staphylococcus aureus, both methicillin sensitive (MSSA) and methicillin resistant (MRSA), have an increased risk for health-care associated infections. Despite WHO recommendations there is currently no national screening and eradication policy for the detection of MSSA in the UK or USA. This study aimed to evaluate the effectiveness of current standard MRSA eradication therapies in the context of S. aureus decolonisation prior to joint replacement surgery. Methods. Pre-operative PCR nasal screening was performed in 273 Orthopaedic patients awaiting joint replacement surgery. In all 100 patients were positive for S. aureus and enrolled into the study. All enrolled patients received and were instructed to administer the decolonisation regimen for five days. Prior to commencement of the eradication therapy swabs of the anterior nares, throat, and perineum were taken for culture. Further culture swabs were taken at; 48–96 hours after completion of the five-day eradication regimen, at hospital admission for surgery, and at hospital discharge. Patients were followed up for six weeks post-surgery. Following completion of the five-day course patients were asked to provide feedback on their experience using Likert rating scales. The primary outcome of this study was S. aureus clearance 48–96 hours post-completion of eradication therapy. Results. At 48–96 hours post-completion there was S. aureus clearance from: the anterior nares 93.8% (95% Confidence Interval (CI) 79.2–99.2%), throat 65.6% (95% CI 46.8–81.4%), and groin 87.5% (95%CI 71–96.5). Mean compliance with nasal mupirocin was 98.2% (standard deviation ±5.2). There was no statistically significant recolonisation effect between completion of eradication therapy and the day of surgery (P>0.05) at a median time of 9.5 days (Interquartile range 6–13 days) at all sites. Discussion and Conclusion. Current MRSA decolonisation regimens are well-tolerated and effective for S. aureus decolonisation for the anterior nares and groin. The decolonisation effect is preserved for up to 10 days following completion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 13 - 13
1 Jun 2012
Cunningham I Spencer S Kinninmonth A
Full Access

In this study we aimed to identify which anatomical site was the most effective for methicillin resistant staphylococcus aureus (MRSA) detection within an elective orthopaedic setting. A retrospective review was performed of 13,373 elective orthopaedic patients from pre-assessment and admission screening swabs taken over a five year period (2005-2010). Swabs were taken from the nose, the axilla and either the groin or perineum. MRSA was identified in 136(1.02%) of patients. The nose was found to be positive for MRSA in 89.6% of cases identified. Therefore only 10.4% of the MRSA carriers (0.1% of all admissions) would not have been identified had a single nasal swab been taken. There was no additional benefit in swabbing the axilla. We believe that for the majority of orthopaedic elective admissions a single nasal swab should be sufficient. In hip arthroplasty patients it may be beneficial to additionally swab the groin given the close proximity of the surgical wound


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 111 - 111
1 Jan 2017
O'Callaghan J Clark D Jackson M LIvingstone J Mitchell S Atkins R
Full Access

The implementation of knee arthrodesis has become synonymous with limb salvage in the presence of chronic sepsis and bone loss around the knee. This can be seen in failed trauma surgery or knee arthroplasty as an alternative to trans-femoral amputation. There is no prior literature assessing which factors affect knee arthrodesis using external fixation devices. Sixteen consecutive patients (four women and twelve men) made up of eleven infected knee implants, three internal fixations of the tibial following fractured tibial plateau as well as 2 infected native joints were identified. The mean age at initial surgery was 56 years (range 25 to 82 years). All procedures were performed under the direct supervision of the limb reconstruction teams using a standard protocol with either a Taylor spatial frame or Ilizarov frame. The patient records, microbiology results and radiographs of all patients who underwent knee arthrodesis at this institution between 1999 and 2010 were reviewed. Of the 16 patients in this study knee fusion occurred in eleven patients (69%). The five patients where arthrodesis failed all had significant bone loss on the pre-operative radiographs and confirmed at surgery. We found a relationship between a significant infection of the knee with MRSA and failure to fuse. Three of the five patients had MRSA isolated from inside the knee at some stage during their treatment. The five patients where fusion failed were on average older (mean age 63 years against 51 years) and had more extensive bone loss. Those who failed to fuse had more co-morbidities. We would conclude that where there is little or no bone loss, arthrodesis of the knee can be reliably achieved with the use of circular frame fixation. A greater number of negative factors also prolongs the amount of time spent in the external fixator. The presence of significant bone loss, infection, increased age and multiple co-morbidities requires careful evaluation and consideration of trans-femoral amputation as an alternative


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 15 - 15
1 May 2017
Colby A Montgomery S
Full Access

Background and Aims. Daily senior review is of paramount importance to provide optimal clinical care and facilitate timely discharge. Also, the General Medical Council state in Good Medical Practice 2013 that “work should be recorded clearly, accurately and legibly…containing relevant clinical findings, decisions made and actions agreed”. This audit aims to evaluate whether all trauma and elective Orthopaedic patients at one unit receive a daily senior review, which is fully documented in the case-notes, and whether a Comprehensive Unit-based Safety Programme (CUSP) toolkit can better facilitate this?. Methods. Case-notes for all patients admitted under Trauma and Orthopaedics on three separate non-consecutive days during a two-week period were scrutinized, examining them for the presence of CUSP toolkits and whether these were adequately completed. Results. 71 case-notes containing 291 CUSP toolkits were analysed. 46.4% had a completed toolkit for everyday since admission; however for those that did not, over half (55.2%) did not have a senior review documented elsewhere for the missing days. Only 1.4% of case-notes had a full complement of up-to-date CUSP toolkits completed entirely correctly. For patients on Orthopaedic wards, most common errors were failure to document date and time (69.7% incorrect), ward and bed number (30.7% incorrect), patient alerts (70.7% incorrect) and overall compliance in documentation of required parameters such as MRSA status, investigations, observation and fluid charts (23% incorrect). Conclusion. In conclusion, better education for clinical staff is needed to improve compliance both with daily senior review, CUSP toolkits and overall documentation to provide optimum patient care


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 38 - 38
1 Mar 2013
Yassa R Veravalli K Evans A
Full Access

Late infection is the most frequent complications after hemiarthroplasty. Urinary tract infections are the only distant septic focus considered to be a risk factor in the literature. We retrospectively reviewed 460 patients with hip fracture treated by hemiarthroplasy over a period of one year. Preoperative positive urine dipsticks and urine analysis have been looked at as causes for delay of surgery in absence of clinical manifestations of urinary tract infection. 367 patients were operated within 24 hours. 78 patients were delayed more than 78 hours. Urinary tract infection had the least contribution as a cause of delay. 99 patients had preoperative urinary tract infection and 57 patients had postoperative wound infection. Of these with postoperative surgical site infection, 31 patients did not show any evidence of preoperative urinary tract infection, 23 patients had preoperative urinary tract infection, two had leg ulcer and one had chest infection. 13 patients had chronic urinary tract infection and five patients had the same causative organism in urine & wound. The most common organisms of urinary infection are E. Coli, mixed growth, Enteroccocus Faecalis, Pseudomonas and others. The most causative organism of the postoperative surgical site infection are Staph aureus including MRSA, mixed growth including Staph. Epidermidis, Enteroccocus Faecalis and others There is no direct significant correlation between preoperative urinary tract infection and surgical site infection. We recommend that preoperative urinary tract infection should be treated as a matter of urgency but it should not delay hip fracture surgery unless it is causing symptoms


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 37 - 37
1 Jul 2014
Molina-Manso D Del-Prado G Lucas-Diaz M Gómez-Barrena E Cordero-Ampuero J Esteban J
Full Access

Summary Statement. Combination of antibiotics with N-acetylcisteine and sub-MIC concentration of erythromycin was evaluated in two collection and 16 clinical strains of staphylococci isolated from PJI. The results were strain-dependent, so it evidences the necessity of perform individual studies of biofilm susceptibility. Objectives. Staphylococci are the most common cause of prosthetic joint infections (PJI) (1), making the treatment of this disease difficult due to the increased resistance to antibiotics of biofilms. Combination between antibiotics and other compounds could be a good alternative. The aim of this study was to evaluate the effect of the combination of two compounds with nine antibiotics in biofilms formed by staphylococcal strains isolated from PJI. Methods. 16 clinical strains (8 S. aureus and 8 S. epidermidis) isolated from patients with PJI as well as 2 collection strains (S. aureus 15981 and S. epidermidis ATCC 35984) were tested against 9 antibiotics (rifampin, vancomycin, tigecycline, clindamycin, cotrimoxazole, ciprofloxacin, cloxacillin, daptomycin and fosfomycin) in combination with NAC 1024 μg/mL and erythromycin at subinhibitory concentration (0.12 μg/mL), which was established after the determination of MIC according to EUCAST recommendations. The Calgary Biofilm Device (CBD) was used to determine the susceptibility of the biofilms to these combinations. The Minimal Biofilm Eradication Concentration (MBEC) for the all the antibiotics alone was determined in a previous study. All the experiments were performed by triplicate. Results. All the S. aureus strains showed homogeneous results, and the addition of NAC or erythromycin at the tested concentrations has not a clear effect in the antibiotic susceptibility of the biofilm, although combination of tigecycline with NAC seems even to increase the MBEC in most cases. Almost all clinical strains were MRSA. Regarding S. epidermidis strains, the results were strain-dependant. The combination with NAC seems to increase the MBEC for rifampin and tigecycline in some strains. However, there was a slight MBEC decrease with cotrimoxazole, ciprofloxacin, cloxacillin, daptomycin and fosfomycin. Erythromycin combinations resulted to be successful only in a few cases, and there is no an apparent relationship between erythromycin resistance and combination results. It is especially remarkable that one strain (P-23.2) showed a slight decrease of the MBEC combining both substances with most of the antibiotics tested. Conclusion. None of the combinations tested was clearly effective against biofilms for all strains of both species. This heterogeneity showed the necessity of making an individual study of each strain. The search of new strategies to fight against PJI is mandatory and further investigation is needed


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 49 - 49
1 May 2012
McLaren J Shakesheff K Quirk R Goodship A Bayston R Scammell B
Full Access

Introduction. Open fractures occur with an annual incidence of 11.5 per 100,000 (6900 pa in UK). Infection rates, even with intravenous broad-spectrum antibiotics, remain as high as 22%. For this reason necessary bone grafting is usually delayed until soft-tissue cover of the bone injury is achieved. A biodegradable bone graft that released sustained high concentrations of antibiotics and encouraged osteogenesis, that could be implanted safely on the day of injury would reduce infection rates and avoid reoperation and secondary grafting. The non –union rate (approx 350 pa in UK) should also be reduced. Such a graft, consisting of a PLA/PGA co –polymer and containing antibiotics, is under development and here we report assessment of spectrum and duration of antimicrobial activity and effect of addition of antibiotics on mechanical properties. Methods. Varying concentrations of gentamicin, colistin, clindamycin and trimethoprim, singly and in combination, were added to the copolymer and test pieces were made. These were then tested using an established method (SPTT) which determines degree and duration of antimicrobial activity as well as risk of emerging resistance. Test bacteria were Staphylococcus epidermidis, Staphylococcus aureus, MRSA and Escherichia coli. Mechanical properties (compressive strength and porosity) were determined using established methods. Results. A combination of gentamicin (4%w/w) and clindamycin (2.5% w/w) gave best results, with inhibitory activity persisting for over 21 days (the target duration) without emergence of resistance. No significant effect of this combination/concentration on mechanical properties was found. Conclusions. The experimental PLA/PGA scaffold containing antibiotics showed activity against the common pathogens of open fractures for a period considered long enough to eradicate contamination acquired at or soon after trauma. At the optimum concentration, they had no significant effect on mechanical properties. In vivo performance is currently being investigated in a sheep model


Bone & Joint Research
Vol. 2, Issue 10 | Pages 220 - 226
1 Oct 2013
Chang Y Tai C Hsieh P Ueng SWN

Objectives

The objective of this study is to determine an optimal antibiotic-loaded bone cement (ALBC) for infection prophylaxis in total joint arthroplasty (TJA).

Methods

We evaluated the antibacterial effects of polymethylmethacrylate (PMMA) bone cements loaded with vancomycin, teicoplanin, ceftazidime, imipenem, piperacillin, gentamicin, and tobramycin against methicillin-sensitive Staphylococcus aureus (MSSA), methicillin-resistant Staph. aureus (MRSA), coagulase-negative staphylococci (CoNS), Escherichia coli, Pseudomonas aeruginosa, and Klebsiella pneumoniae. Standardised cement specimens made from 40 g PMMA loaded with 1 g antibiotics were tested for elution characteristics, antibacterial activities, and compressive strength in vitro.


Bone & Joint Research
Vol. 3, Issue 8 | Pages 246 - 251
1 Aug 2014
Chang YH Tai CL Hsu HY Hsieh PH Lee MS Ueng SWN

Objectives

The objective of this study was to compare the elution characteristics, antimicrobial activity and mechanical properties of antibiotic-loaded bone cement (ALBC) loaded with powdered antibiotic, powdered antibiotic with inert filler (xylitol), or liquid antibiotic, particularly focusing on vancomycin and amphotericin B.

Methods

Cement specimens loaded with 2 g of vancomycin or amphotericin B powder (powder group), 2 g of antibiotic powder and 2 g of xylitol (xylitol group) or 12 ml of antibiotic solution containing 2 g of antibiotic (liquid group) were tested.


Bone & Joint Research
Vol. 2, Issue 3 | Pages 58 - 65
1 Mar 2013
Johnson R Jameson SS Sanders RD Sargant NJ Muller SD Meek RMD Reed MR

Objectives

To review the current best surgical practice and detail a multi-disciplinary approach that could further reduce joint replacement infection.

Methods

Review of relevant literature indexed in PubMed.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1655 - 1659
1 Dec 2007
Anwar HA Aldam CH Visuvanathan S Hart AJ

The biological significance of cobalt-chromium wear particles from metal-on-metal hip replacements may be different to the effects of the constituent metal ions in solution. Bacteria may be able to discriminate between particulate and ionic forms of these metals because of a transmembrane nickel/cobalt-permease. It is not known whether wear particles are bacteriocidal.

We compared the doubling time of coagulase negative staphylococcus, Staphylococcus aureus and methicillin resistant S. aureus when cultured in either wear particles from a metal-on-metal hip simulator, wear particles from a metal-on-polyethylene hip simulator, metal ions in solution or a control.

Doubling time halved in metal-on-metal (p = 0.003) and metal-on-polyethylene (p = 0.131) particulate debris compared with the control.

Bacterial nickel/cobalt-transporters allow metal ions but not wear particles to cross bacterial membranes. This may be useful for testing the biological characteristics of different wear debris. This experiment also shows that metal-on-metal hip wear debris is not bacteriocidal.


Bone & Joint 360
Vol. 3, Issue 3 | Pages 39 - 40
1 Jun 2014
Arastu M


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 417 - 420
1 Mar 2007
Bielecki TM Gazdzik TS Arendt J Szczepanski T Kròl W Wielkoszynski T

Platelet-rich plasma is a new inductive therapy which is being increasingly used for the treatment of the complications of bone healing, such as infection and nonunion. The activator for platelet-rich plasma is a mixture of thrombin and calcium chloride which produces a platelet-rich gel.

We analysed the antibacterial effect of platelet-rich gel in vitro by using the platelet-rich plasma samples of 20 volunteers. In vitro laboratory susceptibility to platelet-rich gel was determined by the Kirby-Bauer disc-diffusion method. Baseline antimicrobial activity was assessed by measuring the zones of inhibition on agar plates coated with selected bacterial strains.

Zones of inhibition produced by platelet-rich gel ranged between 6 mm and 24 mm (mean 9.83 mm) in diameter. Platelet-rich gel inhibited the growth of Staphylococcus aureus and was also active against Escherichia coli. There was no activity against Klebsiella pneumoniae, Enterococcus faecalis, and Pseudomonas aeruginosa. Moreover, platelet-rich gel seemed to induce the in vitro growth of Ps. aeruginosa, suggesting that it may cause an exacerbation of infections with this organism. We believe that a combination of the inductive and antimicrobial properties of platelet-rich gel can improve the treatment of infected delayed healing and nonunion.


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 845 - 850
1 Jun 2014
Romanò CL Logoluso N Meani E Romanò D De Vecchi E Vassena C Drago L

The treatment of chronic osteomyelitis often includes surgical debridement and filling the resultant void with antibiotic-loaded polymethylmethacrylate cement, bone grafts or bone substitutes. Recently, the use of bioactive glass to treat bone defects in infections has been reported in a limited series of patients. However, no direct comparison between this biomaterial and antibiotic-loaded bone substitute has been performed.

In this retrospective study, we compared the safety and efficacy of surgical debridement and local application of the bioactive glass S53P4 in a series of 27 patients affected by chronic osteomyelitis of the long bones (Group A) with two other series, treated respectively with an antibiotic-loaded hydroxyapatite and calcium sulphate compound (Group B; n = 27) or a mixture of tricalcium phosphate and an antibiotic-loaded demineralised bone matrix (Group C; n = 22). Systemic antibiotics were also used in all groups.

After comparable periods of follow-up, the control of infection was similar in the three groups. In particular, 25 out of 27 (92.6%) patients of Group A, 24 out of 27 (88.9%) in Group B and 19 out of 22 (86.3%) in Group C showed no infection recurrence at means of 21.8 (12 to 36), 22.1 (12 to 36) and 21.5 (12 to 36) months follow-up, respectively, while Group A showed a reduced wound complication rate.

Our results show that patients treated with a bioactive glass without local antibiotics achieved similar eradication of infection and less drainage than those treated with two different antibiotic-loaded calcium-based bone substitutes.

Cite this article: Bone Joint J 2014; 96-B:845–50.