Advertisement for orthosearch.org.uk
Results 1 - 20 of 35
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 32 - 32
1 Mar 2012
Seki T Hasegawa Y Kanoh T Matsuoka A
Full Access

Introduction. The purpose of this study was to investigate the long-term outcome of Sugioka's transtrochanteric rotational osteotomy (TRO) for nontraumatic osteonecrosis of the femoral head. Methods. Seventy-eight patients (87 hips) were consecutively treated by TRO from 1989 to 1994. All patients followed 15 years or more were included. Four patients (4 hips) with traumatic osteonecrosis and five patients (5 hips) followed less than 15 years were excluded. A total of 69 patients (78 hips) were included. Average age at the time of operation was 42 years. There were 51 men (57 hips) and 18 women (21 hips). The average follow-up was 17 years (range, 15 to 20 years). Type of osteonecrosis was as follows: Type B; 2 hips, Type C1; 50 hips, and Type C2; 26 hips. Stage was as follows: stage 2; 29 hips, stage 3A; 34 hips, stage 3B; 13 hips, and stage 4; 2 hips. Transtrochanteric anterior rotational osteotomy was performed in 76 hips and posterior rotational osteotomy was performed in 2 hips. Clinical evaluation was evaluated by Harris hip score. Kaplan-Meier survivorship analysis was performed based on the end point of conversion to total hip arthroplasty (THA) or re-collapse. Results. Twenty-nine hips (37.2%) were converted to THA, and 38 hips (48.7%) were re-collapsed. Average Harris hip score before operation was improved from 67 to 82 points at final follow-up. The reasons for conversion to THA within five years after osteotomy were cervical fracture or fixation failure, and 10 years after osteotomy progression of osteoarthritis due to re-collapse. Kaplan-Meier survivorship at 10 years after surgery was 69.2% (95% confidence interval: 58.8-79.6) and 15 years after surgery was 61.3% (95% CI: 49.9-72.7) with THA as the end-point. Kaplan-Meier survivorship at 10 years after surgery 50.0% (95% CI: 38.6-61.4) and at 15 years after surgery 50.0% (95% CI: 38.6-61.4) when re-collapse was defined as the end point. Type C1 was significantly better than Type C2. There was no significant difference between the corticosteroid-induced and non-corticosteroid-induced patients. There was no significant difference between the patients with early and late stage. Conclusion. The long-term outcome of transtrochanteric rotational osteotomy for osteonecrosis of the femoral head was excellent. Sixty-three percent of the hips were not converted to THA. Type C2 was a significant risk factor for TRO


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 46 - 46
1 Mar 2012
Motomura G Yamamoto T Suenaga K Nakashima Y Mawatari T Ikemura S Iwamoto Y
Full Access

Introduction. The objective of this study was to verify the long-term outcome of transtrochanteric anterior rotational osteotomy (ARO) for osteonecrosis of the femoral head (ONFH) in young patients with systemic lupus erythematosus (SLE). Methods. Consecutive series of 21 symptomatic ONFH patients with SLE (33 hips), aged 20 to 40 years, underwent ARO between 1980 and 1988. We reviewed the cases of 16 patients (25 hips), which represents a 76% rate of follow-up. Patients included 4 men and 12 women who had a mean age of 29 years at the time of surgery. A Kaplan-Meier curve was used for the survivorship analysis of ARO. Patients with surviving hips were evaluated by the modified Oxford hip score and the Medical Outcomes Study Short Form 36 (SF-36). Results. Twelve hips in 8 patients survived at the final follow-up. The average length of surviving was 25 years (range, 20 to 27 years). Three patients (6 hips) had died of unrelated causes without any conversion at the mean time of 9 years after ARO. Based on Kaplan-Meier analysis with the end point defined as any conversion, the survival rate at 25 years was 73.7% (95% confidence interval, 53.9 to 93.5%). Based on the classification of the modified Oxford hip score, 5 hips were classified as excellent, 2 hips were good, and the remaining 5 hips were fair. The average SF-36 physical component summary score was 34 points and the average mental component summary score was 46 points. The physical component summary scores of 3 patients (53.0, 56.6, 57.1) exceeded the level of the Japanese population norm. Conclusion. In ONFH patients with SLE, ARO achieved a 73.7% survival rate at 25 years


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 51 - 51
1 Apr 2017
Wong S Nicholson J Ahmed I Ning A Keating J
Full Access

Background

Acetabular fractures occur as a result of high-velocity trauma and are often associated with other life threatening injuries. Approximately one-third of these fractures are associated with dislocation of the femoral head but there are only few studies documenting the long term outcomes of this group of acetabular fracture.

Methods

This was undertaken at the Royal Infirmary of Edinburgh which provides the definitive orthopaedic treatment for all major trauma including all acetabular fractures for the South East of Scotland. We retrospectively reviewed patients who sustained an acetabular fracture associated with a posterior hip dislocation from a prospectively gathered trauma database between 1990 to 2010. Patient characteristics, complications and the requirement for further surgery were recorded. Patient outcomes were measured using the Oxford Hip score and Short Form SF-12 health survey.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 51 - 51
1 Nov 2018
Negri S Regis D Sandri A Magnan B
Full Access

Introduction. The management of periprosthetic pelvic bone loss is a challenging problem in hip revision surgery. This study evaluates the minimum 10-year clinical and radiographic outcome of major column structural allografts combined with the Burch-Schneider antiprotrusio cage for acetabular reconstruction. Methods. From January 1992 to August 2005, 106 hips with periprosthetic osteolysis underwent acetabular revision using massive allografts and the Burch-Schneider antiprotrusio cage. Forty-five patients (49 hips) died for unrelated causes without further surgery. Fifty-nine hips in 59 patients underwent clinical and radiographic evaluation at an average follow-up of 15.1 years. There were 17 male and 42 female patients, with age ranging from 29 to 83 years (mean 59). Results. Ten hips required rerevision because of infection (3), aseptic loosening (6), and flange breakage (1). Moreover, 4 cages showed x-ray signs of instability with severe bone resorption. The survivorship of the Burch-Schneider cage at 21.9 years with removal for any reason or radiographic migration and aseptic or radiographic failure as the end points were 76.3 and 81.4, respectively. The average Harris hip score improved from 33.2 points preoperatively to 75.7 points at the latest follow-up (p < 0.001). Discussion. In hip revision surgery, severe deficiency of pelvic bone stock is a critical concern because of the difficulty in providing a stable and durable fixation of the prosthesis. Although antiprotrusio cages have a limited role in acetabular revision, the use in association with massive allografts in extended bone loss demonstrated highly successful long-term results, enabling bone stock restoration and cup stability.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 6 - 6
14 Nov 2024
Karjalainen L Lähdesmäki M Ylitalo A Eskelinen A Mattila VM Repo J
Full Access

Background. Cephalomedullary nails are widely used for fixation of unstable pertrochanteric fractures. In 2018, the Depuy Synthes Trochanteric Fixation Nail - Advanced (TFNA) implant was introduced at a level I academic trauma center. Thereafter, the TFNA swiftly replaced the older implant models used at the time. Subsequently, clinical concerns were raised about the use of the TFNA due to reports of nail breakage. The purpose of this study was to investigate whether the concerns raised about the performance of the TFNA were valid and to assess long-term outcomes. Methods. The data consisted of 2397 patients who had undergone a proximal femoral hip fracture procedure between 2014 and 2020. Data were handpicked from patient records. TFNA was compared with TFN, PFNA, Gamma3, and Intertan regarding nail breakage, breakage time and long-term outcomes. Results. After exclusion a total of 23/1667 (1.4%) nails broke during the follow-up period. The TFNA broke the most often with 15 cases (2.0%), followed by the Gamma3 with five cases (1.1 %) and the PFNA with three cases (1.3%). Overall, the mean (SD) nail breakage time was 233 (147.8) days. However, for the TFNA, PFNA, and Gamma3, the mean breakage times were 176.8 days (109.9), 419 days (108.6), and 291.8 (153.4), respectively. In cox regression analysis we observed significant reduction in nail breakage when using PFNA with adjusted hazard risk of 0.081 [95% Ci, 0.011-0.576, p=0.011]. Conclusions. In our data, the TFNA had a slightly higher risk for nail breakage when compared to the PFNA and the Gamma3, with a risk difference of 0.7% and 0.9%, respectively. On average, the TFNA broke nearly four months earlier than the Gamma3 and more than eight months earlier than the PFNA. It should be noted, however, that implant breakage is a relatively infrequent complication


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 128 - 128
14 Nov 2024
Nielsen CL
Full Access

Introduction. Vascularized fibular grafting following tumor resection is an essential treatment option in limb salvage surgery. This study aimed to assess the surgical and oncological outcomes of patients treated in Denmark between 2010 and 2022. Method. We present a retrospective review of a national cohort comprising 27 patients. The indications were 13 cases of Ewing sarcoma, 12 cases of osteosarcoma, and 2 cases of giant cell tumor. The median age at surgery was 16 years (range: 2-39), and the median follow-up was 82 months (range: 12-138). Patients were analyzed overall and stratified into upper and lower extremity groups based on tumor location. Result. The primary rate of graft union was 63%, and after secondary procedures, the overall rate of graft union was 67%, with a median time to union of 13 months (range: 7-29). The reoperation rate was 74%, while the rate of limb salvage was 93%, with two patients undergoing amputation during follow-up. The 5-year overall survival rate was 81% (95% CI: 61-92). Patients with upper extremity tumors were more likely to attain graft union (92% vs. 47%, p=0.02) and less likely to undergo multiple reoperations (17% vs 60%, p=0.047) compared to patients with lower extremity tumors. Conclusion. Vascularized fibula grafting remains a valuable option in limb salvage surgery with acceptable long-term outcomes. However, especially in lower extremity cases, a low rate of graft union and multiple reoperations are to be expected


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 75 - 75
17 Apr 2023
Tierney L Kuiper J Williams M Roberts S Harrison P Gallacher P Jermin P Snow M Wright K
Full Access

The objectives of the study were to investigate demographic, injury and surgery/treatment-associated factors that could influence clinical outcome, following Autologous Chondrocyte Implantation (ACI) in a large, “real-world”, 20 year longitudinally collected clinical data set. Multilevel modelling was conducted using R and 363 ACI procedures were suitable for model inclusion. All longitudinal post-operative Lysholm scores collected after ACI treatment and before a second procedure (such as knee arthroplasty but excluding minor procedures such as arthroscopy) were included. Any patients requiring a bone graft at the time of ACI were excluded. Potential predictors of ACI outcome explored were age at the time of ACI, gender, smoker status, pre-operative Lysholm score, time from surgery, defect location, number of defects, patch type, previous operations, undergoing parallel procedure(s) at the time of ACI, cell count prior to implantation and cell passage number. The best fit model demonstrated that for every yearly increase in age at the time of surgery, Lysholm scores decreased by 0.2 at 1-year post-surgery. Additionally, for every point increase in pre-operative Lysholm score, post-operative Lysholm score at 1 year increased by 0.5. The number of cells implanted also impacted on Lysholm score at 1-year post-op with every point increase in log cell number resulting in a 5.3 lower score. In addition, those patients with a defect on the lateral femoral condyle (LFC), had on average Lysholm scores that were 6.3 points higher one year after surgery compared to medial femoral condyle (MFC) defects. Defect grade and location was shown to affect long term Lysholm scores, those with grade 3 and patella defects having on average higher scores compared to patients with grade 4 or trochlea defects. Some of the predictors identified agree with previous reports, particularly that increased age, poorer pre-operative function and worse defect grades predicted poorer outcomes. Other findings were more novel, such as that a lower cell number implanted and that LFC defects were predicted to have higher Lysholm scores at 1 year and that patella lesions are associated with improved long-term outcomes cf. trochlea lesions


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 33 - 33
17 Nov 2023
Goyal S Winson D Carpenter E
Full Access

Abstract. Objectives. Epiphysiodesis is a commonly used treatment for lower limb angular deformities. However, in recent years, distal tibial growth modulation using ‘eight plates’ or screws has emerged as an alternative treatment for paediatric foot and ankle disorders, such as CTEV. Our objective was to assess the efficacy of distal tibial modulation in correcting various paediatric foot and ankle disorders. Methods. This retrospective study analysed 205 cases of paediatric foot and ankle disorders treated between 2003 and 2022, including only cases where the eight plate or screw was fixed on the anterior surface of the distal tibia. Our aim was to measure post-operative changes in dorsiflexion, the distal tibial angle, and the tibiocalcaneal angle by examining clinical records and radiology reports. Results. We identified nine cases (nine feet) meeting the full inclusion criteria, comprising seven cases of CTEV, one case of arthrogryposis, and one case of cavovarus foot. The cohort consisted of five male and four female patients, with a mean age of 10 years and 9 months at the time of surgery. Seven cases involved the left tibia, and two cases involved the right tibia. The mean time between pre-operative X-ray to surgery was 168 days, and the mean turnaround time between surgery and post-operative X-ray was 588 days. A mean change in the distal tibial angle of 4.33 degrees was noted. However, changes in dorsiflexion were documented in only one case, which showed a change of 13 degrees. Notably, our average distal tibial angle was significantly lower than reported in the literature, at 4.33 degrees. Additionally, some studies in the literature used the Oxford Ankle Foot Questionnaire for Children to assess pre- and post-operative outcomes, but it is important to note that it is validated only for children aged 5 to 16. Furthermore, most cases reported an improved tibiocalcaneal angle except for an anomaly of 105 degrees. We assessed satisfactory patient outcomes using patient notes. Out of the 6 procured notes, one has been discharged. The rest are still under yearly or 6-monthly review and are at various stages, such as physiotherapy, removing the eight plate, or requiring further surgery. The most common presentations at review are plantaris deformity and pain. Conclusions. Our study suggests that distal tibial growth modulation can be an effective treatment option for selected paediatric foot and ankle disorders. However, due to the limited number of cases in our study, the lack of documentation of changes in dorsiflexion, and a lack of pre- and post-operative outcomes using a standardised method, further research is needed to investigate this procedure's long-term outcomes and potential complications. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 35 - 35
1 Dec 2021
Wang K Kenanidis E Miodownik M Tsiridis E Moazen M
Full Access

Abstract. Objectives. Stem malalignment in total hip arthroplasty (THA) has been associated with poor long-term outcomes and increased complications (e.g. periprosthetic femoral fractures). Our understanding of the biomechanical impact of stem alignment in cemented and uncemented THA is still limited. This study aimed to investigate the effect of stem fixation method, stem positioning, and compromised bone stock in THA. Methods. Validated FE models of cemented (C-stem – stainless steel) and uncemented (Corail – titanium) THA were developed to match corresponding experimental model datasets; concordance correlation agreement of 0.78 & 0.88 for cemented & uncemented respectively. Comparison of the aforementioned stems was carried out reflecting decisions made in the current clinical practice. FE models of the implant positioned in varus, valgus, and neutral alignment were then developed and altered to represent five different bone defects according to the Paprosky classification (Type I – Type IIIb). Strain was measured on the femur at 0mm (B1), 40mm (B2), and 80mm (B3) from the lesser trochanter. Results. Cemented constructs had lower strain on the implant neck, and higher overall stiffness and strain on bone compared to uncemented THA. Strain on the bone increased further down the shaft of the femoral diaphysis, and with progressing bone defect severity in all stem alignment cases. Highest strain on the femur was found at B2 in all stem alignment and bone defect models. Varus alignment showed higher overall femoral strain in both fixation methods. Interestingly, in uncemented models, highest strain was shown on femoral bone proximally (B1-B2) in varus alignment, but distally (B3) in neutral alignment. Conclusion. Varus stem alignment showed overall higher strain on femur compared to neutral and valgus. This highlights the crucial role of stem alignment in long term outcomes of THA. Differences between the two stem types should be taken in consideration when interpreting results from this study


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 143 - 143
1 Nov 2021
McCarthy C Mahon J Sheridan G Welch-Phillips A O'Byrne J Kenny P
Full Access

Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the long-term outcomes of this bearing surface


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 111 - 111
1 Nov 2021
Mulder F Senden R Staal H de Bot R van Douveren F Tolk J Meijer K Witlox A
Full Access

Introduction and Objective. Slipped Capital Femoral Epiphysis (SCFE) is one of the most common hip disorders in children and is characterized by a proximal femoral deformity, resulting in early osteoarthritis. Several studies have suggested that SCFE patients after in situ fixation show an altered gait pattern. Early identification of gait alterations might lead to earlier intervention programs to prevent osteoarthritis. The aim of this study is to analyse gait alterations in SCFE patients after in situ fixation compared to typically developed children, using the Computer Assisted Rehabilitation Environment (CAREN) system. Materials and Methods. This is a cross-sectional, multi-center case-control study in the Netherlands. Eight SCFE patients and eight age- and sex-matched typically developed were included from two hospitals. Primary outcomes were kinematic parameters (absolute joint angles), studied with gait analysis using statistical parametric mapping (SPM). Secondary outcomes were spatiotemporal parameters, the Notzli alpha angle, muscle activation patterns (EMG), and clinical questionnaires (VAS, Borg CR10, SF-36, and HOOS), analyzed using non-parametric statistical methods. Results. Patients (mean BMI=28±9 kg/m. 2. ) showed altered gait patterns, with significantly increased external hip rotation and decreased downward pelvic obliquity during the pre-swing phase of the gait cycle compared to typically developed (mean BMI=22±3 kg/m. 2. ). Walking speed, cadence, % stance time, and step length were reduced in SCFE patients. Coefficient of variances of cadence, stance time, and step length were increased. Patients had a mean alpha angle of 64, SD=7.9. Clinical questionnaires showed that general health (SF-36) was 80±25, energy/fatigue (SF-36) was 67±15, pain (VAS) was 0±1.5, and total HOOS score was 85±18. Conclusions. SCFE patients after in situ fixation appear to have developed a compensation mechanism, showing slight alterations in gait parameters, good general health, little functional limitations of the hip, and no self-reported pain. Cam deformities, altered joint loading, and this compensation mechanism might influence long-term early osteoarthritis. BMI reduction should be implemented in care plans, as obesity might also play a role in unfavorable long-term outcomes


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 76 - 76
1 Nov 2021
Turchetto L Saggin S
Full Access

Introduction and Objective. The surgical strategy for acetabular component revision is determined by available host bone stock. Acetabular bone deficiencies vary from cavitary or segmental defects to complete discontinuity. For segmental acetabular defects with more than 50% of the graft supporting the cup it is recommended the application of reinforcement ring or ilioischial antiprotrusio devices. Acetabular reconstruction with the use of the antiprotrusion cage (APC) and allografts represents a reliable procedure to manage severe periprosthetic deficiencies with highly successful long-term outcomes in revision arthroplasty. Objective. We present our experience, results, critical issues and technical innovations aimed at improving survival rates of antiprotrusio cages. Materials and Methods. From 2004 to 2019 we performed 69 revisions of the acetabulum using defrosted morcellized bone graft and the Burch Schneider anti-protrusion cage. The approach was direct lateral in 25 cases, direct anterior in 44. Patients were re-evaluated with standard radiography and clinical examination. Results. Eight patients died from causes not related to surgery, and two patients were not available for follow up. Five patients were reviewed for, respectively, non-osseointegration of the ring, post-traumatic loosening with rupture of the screws preceded by the appearance of supero-medial radiolucency, post-traumatic rupture of the distal flange, post-traumatic rupture of the cemented polyethylene-ceramic insert, and dislocation treated with new dual-mobility insert. Among these cases, the first three did not show macroscopic signs of osseointegration of the ring, and the only areas of stability were represented by the bone-cement contact at the holes in the ring. Although radiographic studies have shown fast remodeling of the bone graft and the implant survival range from 70% to 100% in the 10-year follow up, the actual osseointegration of the ring has yet to be clarified. To improve osseointegration of the currently available APC whose metal surface in contact with the bone is sandblasted, we combined the main features of the APC design long validated by surgical experience with the 3D-Metal Technology for high porosity of the external surface already applied to and validated with the press fit cups. The new APC design is produced with the 3D-Metal technology using Titanium alloy (Ti6Al4V ELI) that Improves fatigue resistance, primary stability and favorable environment for bone graft ingrowth. We preview the results of the first cases with short-term follow up. Conclusions. Acetabular reconstruction with impacted morcellized bone graft and APC is a current and reliable surgical technique that allows the restoration of bone loss with a high survival rate of the implant in the medium to long term. The new 3D Metal Cage is designed to offer high friction for the initial stability. The high porosity of the 3D Metal structure creates a favorable environment for bone growth, thus providing valid secondary fixation reproducing the results achieved with the 3D metal press fit cup


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 56 - 56
1 Apr 2017
Gouk C Rebgetz P Thomas M
Full Access

Background. Distal radius fractures are among the most common fractures encountered in the clinical setting, with a reported incidence of 17%. Of these common fractures, it has been said 60% are intra-articular in nature. Intra-articular or unstable and comminuted fractures represent severe, high energy injuries. There is a considerable amount of controversy as to which fixation method is superior. Even the OA concludes; “comparing external fixation (EF) with open reduction and internal fixation (ORIF) for the treatment of intra-articular distal radius fractures described no consistent benefit of one treatment over another”. There are only a few randomised control trials that go beyond one year to cover the long-term follow up (over two years). There has yet to be a meta-analysis of the long-term outcomes of open reduction internal fixation (ORIF) versus external fixation. We aim to show from this meta-analysis if there is any significant difference in the outcomes of either fixation method in the long-term. Method. We pooled the data of all available randomised control trials that compare the long-term outcomes of ORIF against external fixation of distal radius fractures. We completed a systematic review of PubMed, embase, MEDLINE and the Cochrane Library, from inception to December 2014. We then preformed our meta-analysis using RevMan 5.3 software. Results. We did not determine any significant difference in long-term outcomes when comparing ORIF with external fixation. However 6 of the 11 outcomes supported ORIF. Conclusion. There is no significant difference in the long-term outcomes between ORIF and external fixation. No meta analysis to date, short or long term, has been able to determine which is the superior, yet the future treatment of these fractures looks to be ORIF in the form of volar plating. We recommend before this becomes universal, further research must be carried out. Level of Evidence. Level 1. Disclosures. this was the first author's, Dr CJC Gouk, Masters dissertation at the University of Edinburgh. No financial support was received


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 56 - 56
1 Mar 2021
Moore AJ Palmer C Mallon C Gooberman-Hill R Whitehouse MR Blom AW
Full Access

Prosthetic joint infection (PJI) is an uncommon but serious complication of hip replacement. Over 1,000 operations are performed annually in the United Kingdom for PJI following hip replacement, using either one- or two-stage revision arthroplasty. It is unclear which is preferred by patients and which has the best long-term outcome. This qualitative study aims to describe patient experiences of treatment and recovery following one- and two-stage revision arthroplasty for PJI within the context of a pragmatic randomised controlled trial comparing these two approaches. Semi-structured interviews were conducted with 32 patients undergoing one- or two-stage revision treatment for PJI as part of a UK multi-centre randomised controlled trial. Patients were recruited from 12 participating National Health Service (NHS) Orthopaedic Departments and were interviewed 2–4 months after their first revision surgery and again approximately 18 months later. Final sample size was justified on the basis of thematic saturation. All patients consented to the interview being audio-recorded, transcribed, anonymised and analysed using an inductive thematic approach. Ethical approval was provided by NRES Committee South-West Frenchay, 14/SW/116. Patients in both the one- and two-stage treatment groups described prolonged hospital stays, with burdensome antibiotics and brief physiotherapy treatment. However, following discharge home and during recovery, participants undergoing two-stage revision with an ‘empty hip' or with a spacer reported being physically restricted in almost every aspect of their daily life, resulting in inactivity and confinement to home. Mobility aids were not sufficiently available through the health service for these patients. A key difference is that those with a spacer reported more pain than those without. Approximately one year following their second-stage revision, participants described being more independent and active, but two directly attributed muscle weakness to the lengthy period without a hip and described resulting falls or dislocations that had complicated their recovery. In contrast, those undergoing one-stage revision and CUMARS appeared to be more alike, reporting better mobility, functionality and independence, although still limited. Participants in these groups also reported minimal or no pain following their revision. A key difference between CUMARS and one-stage revision was the uncertainty of whether a second operation was necessary, which participants described as “hanging over them”, while those in the two-stage empty hip or spacer group described a more positive anticipation of a second definitive operation as it marked an end to what was described as a detachment from life. Our findings highlight the differences between patient experiences of recovery following revision arthroplasty, and how this is influenced by the surgical approach and presence or lack of spacers. An understanding of lived experiences following one- and two-stage surgical interventions will complement knowledge about the clinical effectiveness of these different types of revision surgery


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 27 - 27
1 Dec 2021
Edwards T Donovan R Whitehouse M
Full Access

Abstract. Objectives. Intra-articular corticosteroid injections (IACIs) are a well-established non-surgical treatment for the symptoms of osteoarthritis (OA), which can provide short-term improvements in pain, disability and quality of life (QoL). Many patients receive recurrent IACIs as temporary relief of their symptoms. Longer-term outcomes for recurrent IACIs remain less well-researched. This meta-analysis aimed to investigate the longer-term risks and benefits of IACIs beyond 3 months. Methods. We searched MEDLINE, EMBASE, and CENTRAL from inception to January 07, 2021, for randomised controlled trials (RCTs) where patients with OA had received recurrent IACIs. Our primary outcomes were pain and function. Secondary outcomes included QoL, disease progression, radiological changes, and adverse events. Mean differences with 95% confidence intervals were reported. Results. Ten RCTs met eligibility criteria (eight for knee OA [n=378], two for trapeziometacarpal OA [n=57]). Patients received 2–5 injections. Follow-up ranged from 6–24 months. Patients with knee OA showed mild improvement in pain at 3, 6, and 9 months but not at 12 months post-injection compared to baseline. Improvements in function were seen from 3–24 months post-injection, decreasing over time. Improvements in QoL continued at 24 months. For patients with trapeziometacarpal OA, mild improvements in pain, function, and QoL were demonstrated at 3–6 months (and 12 months for pain) compared to baseline. No serious adverse events were recorded. No studies reported on time-to-future interventions, or risk of future periprosthetic joint infection. Conclusions. Only mild improvements in pain, function, and QoL were noted after recurrent IACIs up to 6–24 months post-injection. Existing RCTs on recurrent IACI lacks sufficient follow-up data to assess disease progression and time-to-future interventions. These results will inform the RecUrrent Intra-articular Corticosteroid injections in Osteoarthritis (RUbICOn) study which aims to establish the long-term safety outcomes of IACI through data linkage of clinical practice data, hospital episode statistics, and national PROMs


Bone & Joint 360
Vol. 12, Issue 6 | Pages 49 - 51
1 Dec 2023
Burden EG Whitehouse MR Evans JT


Bone & Joint 360
Vol. 13, Issue 4 | Pages 43 - 45
2 Aug 2024
Evans JT Evans JP Whitehouse MR


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 71 - 71
1 Dec 2020
Pukalski Y Barcik J Zderic I Yanev P Baltov A Rashkov M Richards G Gueorguiev B Enchev D
Full Access

Coronoid fractures account for 2 to 15% of the cases with elbow dislocations and usually occur as part of complex injuries. Comminuted fractures and non-unions necessitate coronoid fixation, reconstruction or replacement. The aim of this biomechanical study was to compare the axial stability achieved via an individualized 3D printed prosthesis with curved cemented intramedullary stem to both radial head grafted reconstruction and coronoid fixation with 2 screws. It was hypothesized that the prosthetic replacement will provide superior stability over the grafted reconstruction and screw fixation. Following CT scanning, 18 human cadaveric proximal ulnas were osteotomized at 40% of the coronoid height and randomized to 3 groups (n = 6). The specimens in Group 1 were treated with an individually designed 3D printed stainless steel coronoid prosthesis with curved cemented intramedullary stem, individually designed based on the contralateral coronoid scan. The ulnas in Group 2 were reconstructed with an ipsilateral radial head autograft fixed with two anteroposterior screws, whereas the osteotomized coronoids in Group 3 were fixed in situ with two anteroposterior screws. All specimens were biomechanically tested under ramped quasi-static axial loading to failure at a rate of 10 mm/min. Construct stiffness and failure load were calculated. Statistical analysis was performed at a level of significance set at 0.05. Prosthetic treatment (Group 1) resulted in significantly higher stiffness and failure load compared to both radial head autograft reconstruction (Group 2) and coronoid screw fixation, p ≤ 0.002. Stiffness and failure load did not reveal any significant differences between Group 2 and Group 3, p ≥ 0.846. In cases of coronoid deficiency, replacement of the coronoid process with an anatomically shaped individually designed 3D printed prosthesis with a curved cemented intramedullary stem seems to be an effective method to restore the buttress function of the coronoid under axial loading. This method provides superior stability over both radial head graft reconstruction and coronoid screw fixation, while achieving anatomical articular congruity. Therefore, better load distribution with less stress at the bone-implant interface can be anticipated. In the clinical practice, implementation of this prosthesis type could allow for early patient mobilization with better short- and long-term treatment outcomes and may be beneficial for patients with irreparable comminuted coronoid fractures, severe arthritic changes or non-unions


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 47 - 47
1 Apr 2018
Wylde V Trela-Larsen L Whitehouse M Blom A
Full Access

Background. Total knee replacement (TKR) is an effective operation for many patients, however approximately 20% of patients experience chronic pain and functional limitations in the months and years following their TKR. If modifiable pre-operative risk factors could be identified, this would allow patients to be targeted with individualised care to optimise these factors prior to surgery and potentially improve outcomes. Psychosocial factors have also been found to be important in predicting outcomes in the first 12 months after TKR, however their impact on long-term outcomes is unknown. This study aimed to identify pre-operative psychosocial predictors of patient-reported and clinician-assessed outcomes at one year and five years after primary TKR. Patients and methods. 266 patients listed for a Triathlon TKR because of osteoarthritis were recruited from pre-operative assessment clinics at one orthopaedic centre. Knee pain and function were assessed pre-operatively and at one and five years post-operative using the WOMAC Pain score, WOMAC Function score and American Knee Society Score (AKSS) Knee score. Pre-operative depression, anxiety, catastrophizing, pain self-efficacy and social support were assessed using patient-reported outcome measures. Statistical analyses were conducted using multiple linear regression and mixed effect linear regression, and adjusted for confounding variables. Results. Higher anxiety was a predictor of worse self-reported pain at one year post-operative. Higher anxiety and catastrophizing were predictive of worse self-reported function at one year post-operative. No psychosocial factors were associated with any outcome measures at five years post-operative. Analysis of change over time found that patients with higher pain self-efficacy had lower pre-operative pain and experienced less improvement in pain up to one year. Higher pain self-efficacy was associated with less improvement in the AKSS up to one year post-operative but more improvement between one and five years post-operative. Conclusion. This study found that pre-operative anxiety and catastrophizing influence outcomes at one year after TKR, highlighting that some patients may benefit from targeted psychological interventions to reduce these risk factors and improve outcomes. However, none of the psychosocial variables assessed were predictors of outcomes at five years post-operative, suggesting that the negative effects of anxiety and catastrophizing on outcome do not persist in the longer term


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 65 - 65
1 Jan 2017
Rivière C Iranpour F Cobb J Howell S Vendittoli P Parratte S
Full Access

The mechanical alignment (MA) for Total Knee Arthroplasty (TKA) with neutral alignment goal has had good overall long-term outcomes. In spite of improvements in implant designs and surgical tools aiming for better accuracy and reproducibility of surgical technique, functional outcomes of MA TKA have remained insufficient. Therefore, alternative, more anatomical options restoring part (adjusted MA (aMA) and adjusted kinematic alignment (aKA) techniques) or the entire constitutional frontal deformity (unicompartment knee arthroplasty (UKA) and kinematic alignment (KA) techniques) have been developed, with promising results. The kinematic alignment for TKA is a new and attractive surgical technique enabling a patient specific treatment. The growing evidence of the kinematic alignment mid-term effectiveness, safety and potential short falls are discussed in this paper. The current review describes the rationale and the evidence behind different surgical options for knee replacement, including current concepts in alignment in TKA. We also introduce two new classification systems for “implant alignments options” and “osteoarthritic knees” that would help surgeons to select the best surgical option for each patient. This would also be valuable for comparison between techniques in future research