Introduction. The purpose of this study was to investigate the
Introduction. The objective of this study was to verify the
Acetabular fractures occur as a result of high-velocity trauma and are often associated with other life threatening injuries. Approximately one-third of these fractures are associated with dislocation of the femoral head but there are only few studies documenting the long term outcomes of this group of acetabular fracture. This was undertaken at the Royal Infirmary of Edinburgh which provides the definitive orthopaedic treatment for all major trauma including all acetabular fractures for the South East of Scotland. We retrospectively reviewed patients who sustained an acetabular fracture associated with a posterior hip dislocation from a prospectively gathered trauma database between 1990 to 2010. Patient characteristics, complications and the requirement for further surgery were recorded. Patient outcomes were measured using the Oxford Hip score and Short Form SF-12 health survey.Background
Methods
Introduction. The management of periprosthetic pelvic bone loss is a challenging problem in hip revision surgery. This study evaluates the minimum 10-year clinical and radiographic outcome of major column structural allografts combined with the Burch-Schneider antiprotrusio cage for acetabular reconstruction. Methods. From January 1992 to August 2005, 106 hips with periprosthetic osteolysis underwent acetabular revision using massive allografts and the Burch-Schneider antiprotrusio cage. Forty-five patients (49 hips) died for unrelated causes without further surgery. Fifty-nine hips in 59 patients underwent clinical and radiographic evaluation at an average follow-up of 15.1 years. There were 17 male and 42 female patients, with age ranging from 29 to 83 years (mean 59). Results. Ten hips required rerevision because of infection (3), aseptic loosening (6), and flange breakage (1). Moreover, 4 cages showed x-ray signs of instability with severe bone resorption. The survivorship of the Burch-Schneider cage at 21.9 years with removal for any reason or radiographic migration and aseptic or radiographic failure as the end points were 76.3 and 81.4, respectively. The average Harris hip score improved from 33.2 points preoperatively to 75.7 points at the latest follow-up (
Background. Cephalomedullary nails are widely used for fixation of unstable pertrochanteric fractures. In 2018, the Depuy Synthes Trochanteric Fixation Nail - Advanced (TFNA) implant was introduced at a level I academic trauma center. Thereafter, the TFNA swiftly replaced the older implant models used at the time. Subsequently, clinical concerns were raised about the use of the TFNA due to reports of nail breakage. The purpose of this study was to investigate whether the concerns raised about the performance of the TFNA were valid and to assess
Introduction. Vascularized fibular grafting following tumor resection is an essential treatment option in limb salvage surgery. This study aimed to assess the surgical and oncological outcomes of patients treated in Denmark between 2010 and 2022. Method. We present a retrospective review of a national cohort comprising 27 patients. The indications were 13 cases of Ewing sarcoma, 12 cases of osteosarcoma, and 2 cases of giant cell tumor. The median age at surgery was 16 years (range: 2-39), and the median follow-up was 82 months (range: 12-138). Patients were analyzed overall and stratified into upper and lower extremity groups based on tumor location. Result. The primary rate of graft union was 63%, and after secondary procedures, the overall rate of graft union was 67%, with a median time to union of 13 months (range: 7-29). The reoperation rate was 74%, while the rate of limb salvage was 93%, with two patients undergoing amputation during follow-up. The 5-year overall survival rate was 81% (95% CI: 61-92). Patients with upper extremity tumors were more likely to attain graft union (92% vs. 47%, p=0.02) and less likely to undergo multiple reoperations (17% vs 60%, p=0.047) compared to patients with lower extremity tumors. Conclusion. Vascularized fibula grafting remains a valuable option in limb salvage surgery with acceptable
The objectives of the study were to investigate demographic, injury and surgery/treatment-associated factors that could influence clinical outcome, following Autologous Chondrocyte Implantation (ACI) in a large, “real-world”, 20 year longitudinally collected clinical data set. Multilevel modelling was conducted using R and 363 ACI procedures were suitable for model inclusion. All longitudinal post-operative Lysholm scores collected after ACI treatment and before a second procedure (such as knee arthroplasty but excluding minor procedures such as arthroscopy) were included. Any patients requiring a bone graft at the time of ACI were excluded. Potential predictors of ACI outcome explored were age at the time of ACI, gender, smoker status, pre-operative Lysholm score, time from surgery, defect location, number of defects, patch type, previous operations, undergoing parallel procedure(s) at the time of ACI, cell count prior to implantation and cell passage number. The best fit model demonstrated that for every yearly increase in age at the time of surgery, Lysholm scores decreased by 0.2 at 1-year post-surgery. Additionally, for every point increase in pre-operative Lysholm score, post-operative Lysholm score at 1 year increased by 0.5. The number of cells implanted also impacted on Lysholm score at 1-year post-op with every point increase in log cell number resulting in a 5.3 lower score. In addition, those patients with a defect on the lateral femoral condyle (LFC), had on average Lysholm scores that were 6.3 points higher one year after surgery compared to medial femoral condyle (MFC) defects. Defect grade and location was shown to affect long term Lysholm scores, those with grade 3 and patella defects having on average higher scores compared to patients with grade 4 or trochlea defects. Some of the predictors identified agree with previous reports, particularly that increased age, poorer pre-operative function and worse defect grades predicted poorer outcomes. Other findings were more novel, such as that a lower cell number implanted and that LFC defects were predicted to have higher Lysholm scores at 1 year and that patella lesions are associated with improved
Abstract. Objectives. Epiphysiodesis is a commonly used treatment for lower limb angular deformities. However, in recent years, distal tibial growth modulation using ‘eight plates’ or screws has emerged as an alternative treatment for paediatric foot and ankle disorders, such as CTEV. Our objective was to assess the efficacy of distal tibial modulation in correcting various paediatric foot and ankle disorders. Methods. This retrospective study analysed 205 cases of paediatric foot and ankle disorders treated between 2003 and 2022, including only cases where the eight plate or screw was fixed on the anterior surface of the distal tibia. Our aim was to measure post-operative changes in dorsiflexion, the distal tibial angle, and the tibiocalcaneal angle by examining clinical records and radiology reports. Results. We identified nine cases (nine feet) meeting the full inclusion criteria, comprising seven cases of CTEV, one case of arthrogryposis, and one case of cavovarus foot. The cohort consisted of five male and four female patients, with a mean age of 10 years and 9 months at the time of surgery. Seven cases involved the left tibia, and two cases involved the right tibia. The mean time between pre-operative X-ray to surgery was 168 days, and the mean turnaround time between surgery and post-operative X-ray was 588 days. A mean change in the distal tibial angle of 4.33 degrees was noted. However, changes in dorsiflexion were documented in only one case, which showed a change of 13 degrees. Notably, our average distal tibial angle was significantly lower than reported in the literature, at 4.33 degrees. Additionally, some studies in the literature used the Oxford Ankle Foot Questionnaire for Children to assess pre- and post-operative outcomes, but it is important to note that it is validated only for children aged 5 to 16. Furthermore, most cases reported an improved tibiocalcaneal angle except for an anomaly of 105 degrees. We assessed satisfactory patient outcomes using patient notes. Out of the 6 procured notes, one has been discharged. The rest are still under yearly or 6-monthly review and are at various stages, such as physiotherapy, removing the eight plate, or requiring further surgery. The most common presentations at review are plantaris deformity and pain. Conclusions. Our study suggests that distal tibial growth modulation can be an effective treatment option for selected paediatric foot and ankle disorders. However, due to the limited number of cases in our study, the lack of documentation of changes in dorsiflexion, and a lack of pre- and post-operative outcomes using a standardised method, further research is needed to investigate this procedure's
Abstract. Objectives. Stem malalignment in total hip arthroplasty (THA) has been associated with poor
Introduction and Objective. Ceramic on Ceramic bearings in Total Hip Arthroplasty (THA) afford a low friction coefficient, low wear rates and extreme hardness. Significant complications include hip squeak, ceramic fracture and poor polyethylene performance in revision procedures due to imbedding of abrasive microscopic ceramic fragments. We report on the results of this bearing at a minimum of 10 years. Materials and Methods. A single-centre retrospective review of 449 THAs was performed. Primary outcome measures included aseptic revision and all-cause revision rates at a minimum of 10 years post operatively. Evaluation of functionality was performed with WOMAC and SF-36 scores which were performed pre-operatively and at intervals of 6 months, one year, 2 years, 5 years and 10 years post operatively. Results. There was a 6.2% (n=28) all-cause and 5.3% (n=24) aseptic revision rate for ceramic on ceramic total hip arthroplasty at minimum of 10 years with a mean time to revision 4.8 years (range 2 months − 11.6 years). Notably, there were 2 revisions for ceramic head fracture, one for ceramic liner fracture, 3 for aseptic loosening and 3 revisions for squeaking. Pain of unknown origin was the most common reason for revision. There was an improvement in postoperative WOMAC scores from a mean of 59.8 (range 15–95) pre-operatively to a mean of 15.6 (range 0–78) at 10 years. Conclusions. This study showed good functional outcomes but high revision rates for CoC THA at a minimum of 10 years. The role for CoC bearings in THA has been called into question in recent years and may continue to decline in popularity, even in younger patients. Further large scale studies are important to assess the
Introduction and Objective. Slipped Capital Femoral Epiphysis (SCFE) is one of the most common hip disorders in children and is characterized by a proximal femoral deformity, resulting in early osteoarthritis. Several studies have suggested that SCFE patients after in situ fixation show an altered gait pattern. Early identification of gait alterations might lead to earlier intervention programs to prevent osteoarthritis. The aim of this study is to analyse gait alterations in SCFE patients after in situ fixation compared to typically developed children, using the Computer Assisted Rehabilitation Environment (CAREN) system. Materials and Methods. This is a cross-sectional, multi-center case-control study in the Netherlands. Eight SCFE patients and eight age- and sex-matched typically developed were included from two hospitals. Primary outcomes were kinematic parameters (absolute joint angles), studied with gait analysis using statistical parametric mapping (SPM). Secondary outcomes were spatiotemporal parameters, the Notzli alpha angle, muscle activation patterns (EMG), and clinical questionnaires (VAS, Borg CR10, SF-36, and HOOS), analyzed using non-parametric statistical methods. Results. Patients (mean BMI=28±9 kg/m. 2. ) showed altered gait patterns, with significantly increased external hip rotation and decreased downward pelvic obliquity during the pre-swing phase of the gait cycle compared to typically developed (mean BMI=22±3 kg/m. 2. ). Walking speed, cadence, % stance time, and step length were reduced in SCFE patients. Coefficient of variances of cadence, stance time, and step length were increased. Patients had a mean alpha angle of 64, SD=7.9. Clinical questionnaires showed that general health (SF-36) was 80±25, energy/fatigue (SF-36) was 67±15, pain (VAS) was 0±1.5, and total HOOS score was 85±18. Conclusions. SCFE patients after in situ fixation appear to have developed a compensation mechanism, showing slight alterations in gait parameters, good general health, little functional limitations of the hip, and no self-reported pain. Cam deformities, altered joint loading, and this compensation mechanism might influence long-term early osteoarthritis. BMI reduction should be implemented in care plans, as obesity might also play a role in unfavorable
Introduction and Objective. The surgical strategy for acetabular component revision is determined by available host bone stock. Acetabular bone deficiencies vary from cavitary or segmental defects to complete discontinuity. For segmental acetabular defects with more than 50% of the graft supporting the cup it is recommended the application of reinforcement ring or ilioischial antiprotrusio devices. Acetabular reconstruction with the use of the antiprotrusion cage (APC) and allografts represents a reliable procedure to manage severe periprosthetic deficiencies with highly successful
Background. Distal radius fractures are among the most common fractures encountered in the clinical setting, with a reported incidence of 17%. Of these common fractures, it has been said 60% are intra-articular in nature. Intra-articular or unstable and comminuted fractures represent severe, high energy injuries. There is a considerable amount of controversy as to which fixation method is superior. Even the OA concludes; “comparing external fixation (EF) with open reduction and internal fixation (ORIF) for the treatment of intra-articular distal radius fractures described no consistent benefit of one treatment over another”. There are only a few randomised control trials that go beyond one year to cover the long-term follow up (over two years). There has yet to be a meta-analysis of the
Prosthetic joint infection (PJI) is an uncommon but serious complication of hip replacement. Over 1,000 operations are performed annually in the United Kingdom for PJI following hip replacement, using either one- or two-stage revision arthroplasty. It is unclear which is preferred by patients and which has the best
Abstract. Objectives. Intra-articular corticosteroid injections (IACIs) are a well-established non-surgical treatment for the symptoms of osteoarthritis (OA), which can provide short-term improvements in pain, disability and quality of life (QoL). Many patients receive recurrent IACIs as temporary relief of their symptoms. Longer-term outcomes for recurrent IACIs remain less well-researched. This meta-analysis aimed to investigate the longer-term risks and benefits of IACIs beyond 3 months. Methods. We searched MEDLINE, EMBASE, and CENTRAL from inception to January 07, 2021, for randomised controlled trials (RCTs) where patients with OA had received recurrent IACIs. Our primary outcomes were pain and function. Secondary outcomes included QoL, disease progression, radiological changes, and adverse events. Mean differences with 95% confidence intervals were reported. Results. Ten RCTs met eligibility criteria (eight for knee OA [n=378], two for trapeziometacarpal OA [n=57]). Patients received 2–5 injections. Follow-up ranged from 6–24 months. Patients with knee OA showed mild improvement in pain at 3, 6, and 9 months but not at 12 months post-injection compared to baseline. Improvements in function were seen from 3–24 months post-injection, decreasing over time. Improvements in QoL continued at 24 months. For patients with trapeziometacarpal OA, mild improvements in pain, function, and QoL were demonstrated at 3–6 months (and 12 months for pain) compared to baseline. No serious adverse events were recorded. No studies reported on time-to-future interventions, or risk of future periprosthetic joint infection. Conclusions. Only mild improvements in pain, function, and QoL were noted after recurrent IACIs up to 6–24 months post-injection. Existing RCTs on recurrent IACI lacks sufficient follow-up data to assess disease progression and time-to-future interventions. These results will inform the RecUrrent Intra-articular Corticosteroid injections in Osteoarthritis (RUbICOn) study which aims to establish the
Coronoid fractures account for 2 to 15% of the cases with elbow dislocations and usually occur as part of complex injuries. Comminuted fractures and non-unions necessitate coronoid fixation, reconstruction or replacement. The aim of this biomechanical study was to compare the axial stability achieved via an individualized 3D printed prosthesis with curved cemented intramedullary stem to both radial head grafted reconstruction and coronoid fixation with 2 screws. It was hypothesized that the prosthetic replacement will provide superior stability over the grafted reconstruction and screw fixation. Following CT scanning, 18 human cadaveric proximal ulnas were osteotomized at 40% of the coronoid height and randomized to 3 groups (n = 6). The specimens in Group 1 were treated with an individually designed 3D printed stainless steel coronoid prosthesis with curved cemented intramedullary stem, individually designed based on the contralateral coronoid scan. The ulnas in Group 2 were reconstructed with an ipsilateral radial head autograft fixed with two anteroposterior screws, whereas the osteotomized coronoids in Group 3 were fixed in situ with two anteroposterior screws. All specimens were biomechanically tested under ramped quasi-static axial loading to failure at a rate of 10 mm/min. Construct stiffness and failure load were calculated. Statistical analysis was performed at a level of significance set at 0.05. Prosthetic treatment (Group 1) resulted in significantly higher stiffness and failure load compared to both radial head autograft reconstruction (Group 2) and coronoid screw fixation, p ≤ 0.002. Stiffness and failure load did not reveal any significant differences between Group 2 and Group 3, p ≥ 0.846. In cases of coronoid deficiency, replacement of the coronoid process with an anatomically shaped individually designed 3D printed prosthesis with a curved cemented intramedullary stem seems to be an effective method to restore the buttress function of the coronoid under axial loading. This method provides superior stability over both radial head graft reconstruction and coronoid screw fixation, while achieving anatomical articular congruity. Therefore, better load distribution with less stress at the bone-implant interface can be anticipated. In the clinical practice, implementation of this prosthesis type could allow for early patient mobilization with better short- and
Background. Total knee replacement (TKR) is an effective operation for many patients, however approximately 20% of patients experience chronic pain and functional limitations in the months and years following their TKR. If modifiable pre-operative risk factors could be identified, this would allow patients to be targeted with individualised care to optimise these factors prior to surgery and potentially improve outcomes. Psychosocial factors have also been found to be important in predicting outcomes in the first 12 months after TKR, however their impact on
The mechanical alignment (MA) for Total Knee Arthroplasty (TKA) with neutral alignment goal has had good overall