Advertisement for orthosearch.org.uk
Results 1 - 20 of 44
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 223 - 223
1 Jan 2013
Singh N Kulkarni R Kulkarni G
Full Access

Patient's non acceptance of a bulky external fixator, the incidence of fractures of the regenerate, muscle transfixion giving rise to contractures especially in the Tendo Achilles, increased index of consolidation and the frequency of infections has made Limb lengthening with external fixators alone unpopular. In a retrospective study, we evaluated the technique of limb lengthening over a sub muscular plate combined with Ilizarov external fixator as an alternative to external fixator alone and whether the combined procedure is successful in reducing the external fixator period. 15 patients (14 with length discrepancy in the lower limb and 1 with low stature) and a total of 16 limbs (15 tibiae and 1 femur) were lengthened over a sub muscular plate fixed on the proximal segment followed by corticotomy and application of external fixator. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. The pre operative target length was successfully achieved in all patients at a mean of 4.4 cm (2.2 to 6.5 cm). The mean duration of external fixation was 59.2 days (33 to 107 days) with the mean external fixation index at 16.7 days/cm (10.95 to 23.78). Infection complicated the procedure in two patients and one patient had mild Tendo Achilles contracture. Lengthening over a plate drastically reduces the time external fixator needs to worn and is preferred by patients to limb lengthening over an external fixator alone. patient Lengthening over a plate provides an alternative method for limb lengthening, can be applied to children with open physes and to deformed bones. [Lengthening over a Plate]


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 10 | Pages 1394 - 1399
1 Oct 2009
Oh C Song H Kim J Choi J Min W Park B

Ten patients, who were unsuitable for limb lengthening over an intramedullary nail, underwent lengthening with a submuscular locking plate. Their mean age at operation was 18.5 years (11 to 40). After fixing a locking plate submuscularly on the proximal segment, an external fixator was applied to lengthen the bone after corticotomy. Lengthening was at 1 mm/day and on reaching the target length, three or four screws were placed in the plate in the distal segment and the external fixator was removed. All patients achieved the pre-operative target length at a mean of 4.0 cm (3.2 to 5.5). The mean duration of external fixation was 61.6 days (45 to 113) and the mean external fixation index was 15.1 days/cm (13.2 to 20.5), which was less than one-third of the mean healing index (48 days/cm (41.3 to 55). There were only minor complications. Lengthening with a submuscular locking plate can successfully permit early removal of the fixator with fewer complications and is a useful alternative in children or when nailing is difficult


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 938 - 942
1 Jul 2006
Singh S Lahiri A Iqbal M

Limb lengthening by callus distraction and external fixation has a high rate of complications. We describe our experience using an intramedullary nail (Fitbone) which contains a motorised and programmable sliding mechanism for limb lengthening and bone transport. Between 2001 and 2004 we lengthened 13 femora and 11 tibiae in ten patients (seven men and three women) with a mean age of 32 years (21 to 47) using this nail. The indications for operation were short stature in six patients and developmental or acquired disorders in the rest. The mean lengthening achieved was 40 mm (27 to 60). The mean length of stay in hospital was seven days (5 to 9). The mean healing index was 35 days/cm (18.8 to 70.9). There were no cases of implant-related infection or malunion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 43 - 43
1 Sep 2012
Rashid M Shoaib A Groom W Varma R Groom A
Full Access

Limb lengthening with external fixators has many complications, like pin track infection, joint stiffness, severe pain and stress fracture after removal of external fixator. Prolonged period in external fixator interferes with rehabilitation and activities of daily living. We describe our results with ISKD (intramedullary skeletal kinetic distractor) system, an internal limb lengthening device, activated with rotations of 3 degrees. In this retrospective cohort we performed lengthening with the use of ISKD in 12 patients from March 2006 to date. Ten patients were included in this study as two patients had not completed the stage of consolidation. There were 7 male and 3 female patients. Their average age was 44 years (range 23–63). The mean follow up period was 16 months (range 12–24 months). Two patients had tibial lengthening and eight patients had femoral lengthening. The average lengthening desired was 42.5 mm (range 2.5 mm–75 mm). The average lengthening achieved was 38 mm. Mean hospital stay was 7 days (range 5–11 days). The distraction index was 1.2 mm/day. The average time to full weight bearing was 6 months (range 4 to 10 months). Mean healing time was 10.25 months. The mean healing index was 90.7 days/cm. If we remove two patients who took long time to heal, the mean healing index drops to 61 days/cm. Two patients needed bone grafting at the distraction site. None of the patients had infection, non-union of the distraction site or breakage of the nail. None of the patients had joint stiffness. All patients were completely satisfied with the treatment and had excellent functional results. We conclude that the low rate of complications, higher patient acceptability and avoidance of external fixation make ISKD a very attractive option for limb lengthening


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims

The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices.

Methods

We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions.


The Bone & Joint Journal
Vol. 101-B, Issue 2 | Pages 178 - 188
1 Feb 2019
Chaudhary MM Lakhani PH

Aims

Double-level lengthening, bone transport, and bifocal compression-distraction are commonly undertaken using Ilizarov or other fixators. We performed double-level fixator-assisted nailing, mainly for the correction of deformity and lengthening in the same segment, using a straight intramedullary nail to reduce the time in a fixator.

Patients and Methods

A total of 23 patients underwent this surgery, involving 27 segments (23 femora and four tibiae), over a period of ten years. The most common indication was polio in ten segments and rickets in eight; 20 nails were inserted retrograde and seven antegrade. A total of 15 lengthenings were performed in 11 femora and four tibiae, and 12 double-level corrections of deformity without lengthening were performed in the femur. The mean follow-up was 4.9 years (1.1 to 11.4). Four patients with polio had tibial lengthening with arthrodesis of the ankle. We compared the length of time in a fixator and the external fixation index (EFI) with a control group of 27 patients (27 segments) who had double-level procedures with external fixation. The groups were matched for the gain in length, age, and level of difficulty score.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 9 - 9
23 Apr 2024
Ramlawi AA McClure P Assayag M
Full Access

Introduction. The practice of limb lengthening using intramedullary nails has surged in popularity in recent years. Our study explores the relationship between femur lengthening and overall height gain in adults undergoing cosmetic limb lengthening with telescoping magnetic intramedullary lengthening nails (MILNs). Materials & Methods. Demographic information, pre- and postoperative radiographic data, and secondary outcomes, such as mechanical angles and sagittal alignment, were analyzed for 42 adult femurs MILNs (PRECICE 2, NuVasive, Inc.). Height was assessed with a digital stadiometer. Limb lengthening was defined as the amount of nail distraction seen on a calibrated weight bearing X-ray at consolidation. mLDFA, mMPTA, MAD, AMA, and femoral sagittal bow were evaluated as secondary outcomes. Results. Mean starting height was 163.5 cm (SD 10.4, range 137–179) Post -lengthening mean height increased to 171.1 cm (SD 10.1, range 146.7–185.3). Average height gain was 7.5 cm (SD 1.3 cm, range 5.1–9.5). Average femoral lengthening was 7.3 cm (SD 1.14, range 4.1–10.1). There were no statistically significant difference between height gain and femur lengthening. Secondary outcomes showed reductions in femoral sagittal bow and AMA. Conclusions. We conclude that measuring femur lengthening is a reliable and accurate method of measuring gained height in deformity-free patients undergoing limb lengthening. We further reason that straightening of both femoral and spinal sagittal bow counteracts potential lengthening loss over the anatomical axis, versus mechanical axis lengthening


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 24 - 24
23 Apr 2024
Thompson E James L Narayan B Peterson N
Full Access

Introduction. Management of deformity involving limb length discrepancy (LLD) using intramedullary devices offers significant benefits to both patients and clinicians over traditional external fixation. Following the withdrawal of the PRECICE nail, the Fitbone became the primary implant available for intramedullary lengthening and deformity correction within our service. This consecutive series illustrates the advantages and complications associated with the use of this device, and describes a novel technique modification for antegrade intramedullary lengthening nails. Materials & Methods. A retrospective cohort review was performed of patient outcomes after treatment with the Fitbone nail at two tertiary referral limb reconstruction services (one adult, one paediatric) between January 2021 to December 2023. Aetiology, indications, initial and final LLD, use of concomitant rail assisted deformity correction (ORDER), removal time and healing index were assessed. Complications of treatment were evaluated and described in detail, alongside technique modifications to reduce the rate of these complications. Results. 21 nails (18 femoral, 2 tibial, 1 humeral) were inserted in 6 adult and 13 paediatric patients. Post-traumatic and congenital/developmental LLD were the most common indications for surgery in the adult and paediatric cohorts respectively. ORDER was employed in 11 cases (9 femurs and 2 tibias). Treatment goals were achieved in all but one case. Complications included superficial infection, locking bolt migration, periprosthetic fracture and component failure. Seven patients required unplanned returns to theatre. Conclusions. The Fitbone nail is an established option for intramedullary limb lengthening, however its use in the UK has been relatively limited compared to the PRECICE until 2021. Our data helps to define its place for limb lengthening and complex deformity correction in both adult and paediatric patients, including in humeral lengthening and retrograde femoral insertion across an open physis. We have identified important potential risks and novel techniques to simplify surgery and avoid complications


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 29 - 29
1 May 2021
Rouse B Giles S Fernandes J
Full Access

Introduction. We have previously published limb lengthening using external fixation in pathological bone diseases. We would like to report a case series of femoral lengthening using the PRECICE system in a similar pathological group especially looking at it's feasibility and complications. Materials and Methods. This is a case series of four patients, two patients with osteogenesis imperfecta and two with Ollier's disease, who underwent femoral lengthening via distraction osteogenesis using the PRECICE intramedullary nail system. It was a retrospective study from a prospective database from clinical records and radiographs. Results. The mean age at the time of surgery was 15.5 years, the mean preoperative leg length discrepancy was 30mm, and the mean distraction distance achieved was 28.75mm. Since these patients were of shorter heigh, limb lengthening was considered. All 4 patients had successful insertion of the nail. The outcomes noted from the 4 patients are collated, with several complications occurring including delayed femoral union, fixed flexion deformity of the hip, persisting pain and quadriceps weakness. Those with Ollier's disease underwent an increased rate of distraction to prevent premature healing. The implications of long-term bisphosphonate therapy in OI are discussed with regards to the risk of delayed femoral union and intra-operative fracture. Conclusions. Intramedullary femoral lengthening in pathological bone disease is possible, but the surgeon needs to give attention to certain details. The regenerate formation is based on the background pathology irrespective of the hardware used. There is much more compliance with the nail technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 28 - 28
1 Jun 2023
Musielak B Green N Giles S Madan S Fernandes J
Full Access

Introduction. Intramedullary lengthening devices have been in use in older children with closed /open growth plates with good success. This study aims to present the early experience of the FITBONE nail since withdrawal of the PRECICE nail. Materials & Methods. Retrospective analysis of both antegrade and retrograde techniques were utilized. Only patients where union was achieved and full weight bearing commenced were included. The complication rate, length gained, distraction index, weight bearing index (WBI) as well as mechanical axes were analysed. Results. 14 (7 males, 7 females) of a total of 16 (7 males, 7 females) patients with a mean age of 16.9 years with varied diagnosis of LLD were analysed. The mean length gained was 38 mm with an average distraction index of 0,74 mm/day. WBI in these patients on average was 59,6 days/cm lengthened. 6 complications were observed, including two nonunions (successfully treated) and a knee subluxation. Mechanical axis deviation improved from 13,3 mm to 6 mm on average. Overall there has been a nonsignificant tendency for WBI to decrease (Spearman's rank correlation coefficient −0.47, p=0.08) with increasing number of cases done, while no correlation between length gained and WBI (−0.01, p=0.96, respectively) was observed. Some nuances will be discussed. Conclusions. Limb lengthening with the FITBONE nail is relatively safe and efficient, however no significant change was seen in the outcome with previous motorized nails


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 17 - 17
23 Apr 2024
Mackarel C Tunbridge R
Full Access

Introduction. Sheffield Children's Hospital specialises in limb lengthening for children. Soft tissue contracture and loss of range of motion at the knee and ankle are common complications. This review aims to look at therapeutic techniques used by the therapy team to manage these issues. Materials & Methods. A retrospective case review of therapy notes was performed of femoral and tibial lengthening's over the last 3 years. Included were children having long bone lengthening with an iIntramedullary nail, circular frame or mono-lateral rail. Patients excluded were any external fixators crossing the knee/ankle joints. Results. 20 tibial and 25 femoral lengthening's met the inclusion criteria. Pathologies included, complex fractures, limb deficiency, post septic necrosis and other congenital conditions leading to growth disturbance. All patients had issues with loss of motion at some point during the lengthening process. The knee and foot/ankle were equally affected. Numerous risk factors were identified across the cohort. Treatment provided included splinting, serial casting, bolt on shoes, exercise therapy, electrical muscle stimulation and passive stretching. Conclusions. Loss of motion in lower limb joints was common. Patients at higher risk were those with abnormal anatomy, larger target lengthening's, poor compliance or lack of access to local services. Therapy played a significant role in managing joint motion during treatment. However, limitations were noted. No one treatment option gave preferential outcomes, selection of treatment needed to be patient specific. Future research should look at guidelines to aid timely input and avoid secondary complications


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 2 - 2
1 Jun 2023
Tay KS Langit M Muir R Moulder E Sharma H
Full Access

Introduction. Circular frames for ankle fusion are usually reserved for complex clinical scenarios. Current literature is heterogenous and difficult to interpret. We aimed to study the indications and outcomes of this procedure in detail. Materials & Methods. A retrospective cohort study was performed based on a prospective database of frame surgeries performed in a tertiary institution. Inclusion criteria were patients undergoing complex ankle fusion with circular frames between 2005 and 2020, with a minimum 12-month follow up. Data were collected on patient demographics, surgical indications, comorbidities, surgical procedures, external fixator time (EFT), length of stay (LOS), radiological and clinical outcomes, and adverse events. Factors influencing radiological and clinical outcomes were analysed. Results. 47 patients were included, with a mean follow-up of three years. The mean age at time of surgery was 63.6 years. Patients had a median of two previous surgeries. The median LOS was 8.5 days, and median EFT was 237 days. Where simultaneous limb lengthening was performed, the average lengthening was 2.9cm, increasing the EFT by an average of 4 months. Primary and final union rates were 91.5% and 95.7% respectively. At last follow-up, ASAMI bone scores were excellent or good in 87.2%. ASAMI functional scores were good in 79.1%. Patient satisfaction was 83.7%. 97.7% of patients experienced adverse events, most commonly pin-site related, with major complications in 30.2% and re-operations in 60.5%. There were 3 amputations. Adverse events were associated with increased age, poor soft tissue condition, severe deformities, subtalar fusions, peripheral neuropathy, peripheral vascular disease, and prolonged EFT. Conclusions. Complex ankle fusion using circular frames can achieve good outcomes in complicated clinical scenarios, however patients can expect a prolonged time in the frame and high rates of adverse events. Multiple risk factors were identified for poorer outcomes, which should be considered in patient counselling and prognostication


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 21 - 21
1 Jun 2023
Wade A Devane Y Nowlan N Donnelly T Green C
Full Access

Introduction. There is no doubt that the future of limb lengthening lies with internal lengthening. Complication rates are reduced and patient satisfaction is increased. The evolution of internal lengthening peaked with the dual direction, easily inserted and externally controlled PRECICE Nail. It has excelled in performance in accuracy and satisfaction. Its versatility increased with smaller sizes and increased excursion. A field safety notice was issued was issued in October 2021 by the parent company NuVasive. The advice was monitoring of current cases and a hold on implantation until after a review of process. At the National Orthopaedic Hospital Cappagh we elected to remove all implanted nails and assess the nail integrity and physiological changes associated with implantation. Materials & Methods. All patients in who a retained Precice nail at the time of the field safety notice were identified. Patients and families were contacted to explain the issued safety notice from the company and explain that we would be scheduling them for nail removal. This was part of our standard care but we prioritised this group on our waiting list. Consent was obtained for nail removal but also for histological assessment of canal scrapings, blood ion level analysis and independent assessment of the retrieved nail by our academic collaborators at University College Dublin. Ion levels were then repeated at an interval post removal with consent. Results. We identified 7 Precice nails in 5 patients still implanted. All patients had consolidated after lengthening and were ready for nail removal. Elevated Titanium blood ion levels were identified at the time of retrieval. Histological abnormalities consistent with metalosis were identified. In all cases the nail was grossly intact and examination of the motor showed no evidence of wear or failure. Follow up ion levels obtained post retrieval showed persistent elevation. Conclusions. Our retrieval audit shows persistent elevation of Titanium ion levels and abnormal histology despite apparent nail integrity. These findings require further evaluation in a larger retrieval series to determine if there is a high incidence of this phenomenon and if ion levels have a clinical effect


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 10 - 10
1 Apr 2022
Baumgart R
Full Access

Introduction. “Bioexpandable” prostheses after resection of malignant bone tumors in children to lengthen the bone using the method of callus distraction may offer new perspectives and better long-term results. Materials and Methods. The bioexpandable prosthesis is equipped with an encapsulated electromotor which enables the device to perform distraction in an osteotomy gap with about 1mm/day. The new bone is improving the ratio from bone to prosthesis and therewith the potential stability of the final stem. The device is indicated, when limb length discrepancy is getting more than 3 cm or at maturity and can be used in a minimal invasive way for femur lengthening. Results. 11 patients were treated with the bioexpandable prosthesis. The mean age of the patients was 13,5 years and the mean amount of lengthening was 74mm. In 2 cases lengthening was performed in 2 steps and in 1 case in 3 steps. All lengthening procedures could be finished without complications. There was no infection and no technical problem. The bone regenerate in one tibia case was poor so that bone grafting from the iliac crest was necessary. Conclusions. The “bioexpandable” prosthesis is a new concept for limb lengthening after tumor resection in children. The latest patented version of the prosthesis under development allows all lengthening manoeuvres and the placement of the final stem via small incisions not only for the femur but also for the tibia


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 21 - 21
1 Apr 2022
Anarat FB Balcı HI Bayram S Eralp L Kocaoglu M Sen C
Full Access

Introduction. The effect of lower extremity lengthening on physeal growth is still controversial. We aim to compare data of the patients who had bilateral simultaneous femur and tibia lengthening with the patients who underwent the lengthening surgery separately for the femur and tibia at the end of completed skeletal maturation in terms of the effect of physeal growth. Materials and Methods. Twenty-six patients were included who operated in our clinic between 1995 and 2015 for limb lengthening. Fourteen patients with bilateral lengthening of the femur and tibia at the same time were named as simultaneous lengthening (SL). Twelve patients with bilateral lengthening of the femur and then bilateral tibia lengthening seperately were named consecutively lengthening (CL). All patients were followed until completion of growth. The physeal arrest was measured using predicted length (investigated with the multiplier method), the total amount of lengthening and final length. Results. Mean lower limb lengthening was 145 mm (48,5%) and 151 mm (46,6%) for simultaneous and consecutive groups respectively. For lower extremity length, the SL reached 527,6 mm while expected was 447,3 mm. Considering 151 mm lengthening, the mean growth disturbance for the SL was 70,7 mm. The CL group revealed a mean of 47,5 mm disturbance. For total height comparison, disturbance was 80,5mm and 65,4mm respectively. Conclusions. Although simultaneous four segment lengthening have more physiological physeal disturbance effects compared to consecutive operations, there was no statistical difference between the two groups


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 40 - 40
1 Apr 2022
Hafez M Nicolaou N Dixon S Obasohan P Giles S Madan S Fernandes J Offiah A
Full Access

Introduction. Motorised intramedullary lengthening nails are considered more expensive than external fixators for limb lengthening. This research aims to compare the cost of femoral lengthening in children using the PRECICE magnetic lengthening nail with external fixation. Materials and Methods. Patients: Retrospective analysis of 50 children who underwent femoral lengthening. One group included patients who were treated with PRECICE lengthening nails, the other group included patients who had lengthening with external fixation. Each group included 25 patients aged between 11–17 years. The patients in both groups were matched for age. Cost analysis was performed following micro-costing and analysis of the used resources during the different phases of the treatments. Results. : Each group's mean patient age was 14.7 years. Lengthening nails were associated with longer operative times compared to external fixators, both for implantation and removal surgery (P-value 0.007 and <0.0001 respectively). Length of stay following the implantation surgery, frequency of radiographs, frequency of outpatient department appointments were all more favourable with lengthening nails. The overall cost of lengthening nails was £1393 more than external fixators, although this difference was not statistically significant (P-value 0.088). Conclusions. The cost of femoral lengthening with lengthening nails was not significantly higher than the external fixators’ cost. Further research to review the effectiveness of the devices and the quality of life during the lengthening process is crucial for robust health economic evaluation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 23 - 23
1 Apr 2022
Balci HI Anarat FB Kocaoglu M Eralp L Sen C Bas A
Full Access

Introduction. This study aims to evaluate the effect of using different types of fixator on the quality of callus and complications during distraction osteogenesis in patients with achondroplasia. Materials and Methods. Forty-nine achondroplasia patients with a minimum follow-up of 36 months who underwent limb lengthening between 2005 and 2017 with external fixator only were included. Thirty-three of the patients underwent lengthening using classical Ilizarov frame, while spatial frame used for sixteen. Regenerate quality is evaluated according to the Li classification on the X-ray taken one month after the end of the distraction. Complications were noted in the follow-up period. Results. The mean age at the time of surgery was 8,6 years. The mean external fixation index (EFI) was 34,3 and 30,1 day/cm for spatial frame and Ilizarov frame respectively. Mean follow-up period of 161,62 months and mean fixator period of 257 days. Amount of lengthening was 7,2 cm for Ilizarov frame, and 7,5 cm for spatial frame. Rate of callus with good morphological quality seen at consolidation was 72,4% and 50% for Ilizarov and spatial frames respectively. Two groups show similar results of complication rates in terms of pin site infection, premature fibular consolidation, regenerate fracture, plastic deformation, knee contracture. However fibular nonunion rates were higher for Ilizarov-type fixator. Conclusions. Although spatial frame with computer assistance brings easier follow-up for deformity correction, Ilizarov-type external fixator show slightly higher rates of good quality callus during consolidation for patients with achondroplasia


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 42 - 42
1 Apr 2022
Guichet J Chekairi A Stride M
Full Access

Introduction. The Patient's Dream is not to stay in hospital even overnight, including in limb lengthening. We developed the ‘Hyper Fast Track Protocol’ (HFTP) in 2015 to fasten recovery and shorten hospital stay. Materials and Methods. The protocol included surgical stab incisions, use of weight bearing lengthening nails (G-Nail), intramedullary saw, a specific anaesthesia care (blood hypo-pressure, tranexamic acid, low hydration), absence of early anticoagulants, systematic vascular US controls, but early motion (hip and knee Ext/Fle, leg raise, horizontal ‘scissors’), walking, stairs, bike, clicking (maneuvers to lengthen), early discharge, along with other patient's parameters. Timing and exercises reps were registered. Protocols improved over time. Means ± SD are computed. Results. Forms were analysed in 112 patients (unilateral 7, dwarfism 2, cosmetic 103). Besides patients operated in the afternoon (18), physio sessions initiated (h:mm) in average 0:46 ± 0:19 after awakening in operative room, for a duration of 2:15 ± 0:46. No DVT was noted on US nor clinically. In 2016, hospitalisation averaged 2.88 nights, decreasing to 2.07 in 2017, then to 1.07 from 2020. In late 2020 and in 2021, we had several patients in Daycare only, even in bilateral lengthening. In late 2021, we could discharge a patient after walking, full motion and exercises 3.5 hours after awakening from bilateral surgery. Conclusions. With continuous result monitoring and constant improvement of Care, walking, stairs, clicks and biking are fully feasible within 3h of surgery awakening, with discharge on the same day, using specific protocols


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1168 - 1176
1 Sep 2019
Calder PR McKay JE Timms AJ Roskrow T Fugazzotto S Edel P Goodier WD

Aims. The Precice intramedullary limb-lengthening system has demonstrated significant benefits over external fixation lengthening methods, leading to a paradigm shift in limb lengthening. This study compares outcomes following antegrade and retrograde femoral lengthening in both adolescent and adult patients. Patients and Methods. A retrospective review of prospectively collected data was undertaken of a consecutive series of 107 femoral lengthening operations in 92 patients. In total, 73 antegrade nails and 34 retrograde nails were inserted. Outcome was assessed by the regenerate healing index (HI), hip and knee range of movement (ROM), and the presence of any complications. Results. The mean lengthening was 4.65 cm (1.5 to 8) in the antegrade group and 4.64 cm (1.6 to 8) in the retrograde group. Of the 107 lengthenings, 100 had sufficient datapoints to calculate the mean HI. This was 31.6 days/cm (15 to 108). There was a trend toward a lower (better) HI with an antegrade nail and better outcomes in adolescent patients, but these were not statistically significant. Hip and knee ROM was maintained and/or improved following commencement of femoral lengthening in 44 patients (60%) of antegrade nails and 13 patients (38%) of retrograde nails. In female patients, loss of movement occurred both earlier and following less total length achieved. Minor implant complications included locking bolt migration and in one patient deformity of the nail, but no implant failed to lengthen and there were no deep infections. Three patients had delayed union, five patients required surgical intervention for joint contracture. Conclusion. This study confirms excellent results in femoral lengthening with antegrade and retrograde Precice nails. There is a trend for better healing and less restriction in hip and knee movement following antegrade nails. There are clinical scenarios, that mandate the use of a retrograde nail. However, when these are not present, we recommend the use of antegrade nailing. Cite this article: Bone Joint J 2019;101-B:1168–1176


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 51 - 51
1 May 2021
Abood AA Petruskevicius J Vogt B Frommer A Rödl R Rölfing JD
Full Access

Introduction. Intraoperative assessment of coronal alignment is important when performing corrective osteotomies around the knee and ankle, limb lengthening and trauma surgery. The Joint Angle Tool (JAT) provides surgeons with information about the anatomic and mechanical axes intraoperatively based on true anteroposterior radiographs. Aim: Presentation of the JAT, a low-cost goniometer for intraoperative assessment of the lower limb alignment. Materials and Methods. The JAT consists of pre-printed joint orientation angles of the anatomic and mechanical axis including normal variations on a plastic sheet. It is placed on the screen of the image intensifier after obtaining a true anterior-posterior image. The pre-printed joint orientation angles can intraoperatively assist the surgeons in achieving the pre-planned axis correction. Here, its feasibility is demonstrated in four cases. Results. Here, we present the intraoperative use of JAT in four cases:. 77 mm femoral bone transport due to non-union utilizing a bone transport nail,. distal femoral osteotomy correcting coronal and torsional malalignment using a retrograde intramedullary trauma nail,. proximal / high tibial open wedge osteotomy with an intramedullary implant correcting varus malalignment in a hypophosphatemic rickets patient, and. a supramalleolar, closing wedge osteotomy realigning the anatomic axis with a plate and screws. Conclusions. The JAT is a modified goniometer which allows intraoperative assessment of the mechanical and anatomic axis. JAT is applicable throughout the entire surgical procedure irrespective of the method of internal fixation and may provide additional reassurance of correct alignment. The JAT consists of a plastic sheet with printed joint orientation angles and their normal variation. JAT is freely available from . profeedback.dk/JAT/JAT.pdf. for use and modification according to Creative Commons license (CC BY-SA 4.0)