Introduction. Through the paediatric
Through the paediatric
Introduction. Coxa vara is an uncommon orthopaedic condition. Problems associated with the definition, radiological appearance, classification and surgical treatment are discussed. Methods. A clinical and radiological review of 11 patients (14 hips) treated with a
INTRODUCTION. Childhood diseases involving the proximal femoral epiphysis often cause abnormalities that can lead to end-stage arthritis at a relatively young age and the need for total hip arthroplasty (THA). The young age of these patients makes hip resurfacing arthroplasty (HRA) an alternative and favorable option due to the ability to preserve femoral bone. Patients presenting with end-stage hip arthritis as sequelae of childhood diseases such as Legg-Calves-Perthes (LCP) and slipped capital femoral epiphysis (SCFE) pose altered femoral anatomy, making HRA more technically complicated.
Distal femur fractures (DFF) are common, especially in the elderly and high energy trauma patients. Lateral locked osteosynthesis constructs have been widely used, however non-union and implant failures are not uncommon. Recent literature advocates for the liberal use of supplemental medial plating to augment lateral locked constructs. However, there is a lack of proprietary medial plate options, with some authors supporting the use of repurposing expensive anatomic pre-contoured plates. The aim of this study was to investigate the feasibility of a readily available cost-effective medial implant option. A retrospective analysis from January 2014 to June 2022 was performed on DFF (primary or revision) managed with supplemental medial plating with a Large Fragment Locking Compression Plate (LCP) T-Plate (~$240 AUD) via a medial sub-vastus approach. The T-plate was contoured and placed superior to the medial condyle. A combination of 4.5mm cortical, 5mm locking and/or 6.5mm cancellous screws were used, with oblique screw trajectories towards the distal lateral cortex of the lateral condyle. All extra-articular fractures and revision fixation cases were allowed to weight bear immediately. The primary outcome was union rate. This technique was utilised on sixteen patients; 3 acute, 13 revisions; mean age 52 years (range 16-85), 81% male, 5 open fractures. The union rate was 100%, with a median time to union of 29 weeks (IQR 18-46). The mean follow-up was 15 months. There were two complications: a deep infection requiring two debridements and a prominent screw requiring removal. The mean range of motion was 1–108. o. . Supplemental medial plating of DFF with a Large Fragment
Purpose. To promote rapid bone healing, an adequate stable fixation implant with a percutaneous reduction instrument should be used for Vancouver type B1 or C fractures. The objective of this study was to describe radiographic and clinical outcomes of patients with periprosthetic fracture (PPF) around a stable femoral stem, treated with a distal femoral locking plate alone or with a cerclage cable. Materials and Methods. A total of 21 patients with PPF amenable to either a reverse distal femoral locking plate (LCP DF. ®. ) alone or with a cerclage cable, with a mean age of 75.7 years, were included. In these patients, 10 fractures were treated with a reverse
Introduction. Patients presenting with osteoarthritis as late sequelae following pediatric hip trauma have few options aside from standard Total Hip Replacement (THR). For younger more active patients, Hip Resurfacing Arthroplasty (HRA) can be offered as an alternative. HRA has been performed in the United States over the past decade and allows increased bone preservation, decreased hip dislocation rates versus THR, and potential to return to full activities. Patients presenting with end-stage hip arthritis as following prior pediatric trauma or disease often have altered hip morphology making HRA more complicated. Often Legg-Calve-Perthes (LCP) patients present with short, wide femoral necks, and femoral head distortion including coxa magna or coxa plana. There often can be acetabular dysplasia in conjunction with the proximal femoral abnormalities. Slipped Capital Femoral Epiphysis (SCFE) patients have an alteration of the femoral neck and head alignment, which can make reshaping the femoral head difficult. In particular, the femoral head is rotated medially and posteriorly, reducing the anterior and lateral offset. We present a cohort of 20 patients, with history of a childhood hip disorder (SCFE or LCP), who underwent HRA to treat end-stage arthritis. Fifty percent had prior pediatric surgical intervention at an average age of 11. Method. After Institutional Review Board approval, data was reviewed retrospectively on patients with pediatric hip diseases of SCFE and
Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm
Fractures of distal tibia are common and often present with dilemma of appropriate and safe management. The use of locking plates has changed the way these fractures have been managed as it avoids extensive soft tissue dissection and periosteal stripping. The aims of this study were to look at the results of stabilization and analyse the complications of fractures of distal tibia treated with Locked plates. We carried out a retrospective study of patients who underwent surgical treatment for distal tibial fractures using MIPO (Minimally invasive Percutaneous Osteosynthesis) technique. The data was gathered from theatre data base. We studied a period between Nov 2006 to May 2009. We collected patient demographics as well as the type of fractures, mechanism of injury, radiological union and associated complications. There were no open fractures in the study. The limb was splinted for two weeks after surgery in a back slab. The patients were followed up at 6 weeks, 3, 6, 9 and 12 months after surgery. There were 45 patients in the study with 29 males & 16 females between ages of 20 – 87 (avg. 49 yrs). 24 patients sustained injury due to a fall, 12 were involved in RTA and the remaining 9 were sports related injuries. The mean time to surgery was 3.15 days (1 – 7) and surgery was carried either by the consultant or their direct supervision. The mean hospital stay was 7 days (2 – 35) and mean time to radiological evidence of callus was 9 weeks. All patients eventually returned to their preinjury employment. 76% showed radiological union at 6 months and 90% at 9 months. There were 3 superficial wound infections, 2 deep infections whilst 2 needed bone grafting and 1 implant failure. 2 patients developed mild form of CRPS which resolved at 12 months. 11 patients had metal discomfort of which 9 had removal of hardware. All these patients had the tip snapped off. MIPO with
INTRODUCTION. In total knee arthroplasty (TKA), the effectiveness of the mechanical alignment (MA) within 0°±3° has been recently questioned. A novel implantation approach, i.e. the kinematic alignment (KA), emerged recently, this being based on the pre-arthritic lower-limb alignment. In KA, the trans-cylindrical axis is used as the reference, instead of the trans-epicondylar one, for femoral component alignment. This axis is defined as the line passing through the centres of the posterior femoral condyles modeled as cylinders. Recently, patient specific instrumentation (PSI) has been introduced in TKA as an alternative to conventional instrumentation. This provides a tool for preoperative implant planning also via KA. Particularly, KA using PSI seems to be more effective in restoring normal joint kinematics and muscle activity. The purpose of this study was to report preliminarily joint kinematic and electromyography results of two patient groups operated via conventional MA or KA, the latter using PSI. PATIENT AND METHODS. Twenty patients recruited for TKA were implanted with Triathlon® prosthesis (Stryker®-Orthopaedics, Mahwah, NJ-USA). Seventeen patients, eleven operated targeting MA using the convention instrumentation (group A) and six targeting KA (group B) using PSI (Stryker®-Orthopaedics), were assessed at 6 month follow-up clinically via IKSS and biomechanically. Knee kinematics during stair-climbing, chair-rising, and extension-against-gravity were evaluated using three-dimensional mono-planar video-fluoroscopy (CAT® Medical-System, Monterotondo, Italy) synchronised with electromyography (Wave-Wireless, Cometa®, Milan, Italy). Component pose was reconstructed to calculate knee flexion/extension (FE), ad/abduction (AA), internal/external-rotation (IE), together with the rotation of the contact-line (CLR), i.e. line connecting the medial (MCP) and lateral (LCP) tibio-femoral contact points. MCP and
The distal femur fracture is a difficult injury that affects young men andelderly women. The tissue stripping that occurs with the traditional approach has been a factor in the development of complications like infection and nonunion. This study addresses the issue of minimally invasive approach. Does the LISS system really improve the results of such fracture?. Fifty-two patients were included in the trial from six academic trauma centres. Twenty-eight fractures had been randomised to be fixed with the LISS device, while twenty-four had the DCS implant. Type C3 fractures were excluded as they were not amenable for fixation with DCS system. All procedures were performed via minimally invasive technique. The LISS system had the targeter that helped with plate insertion and distal diaphyseal screws placement. Radiography was utilised in the case of the DCS distal screws insertion. All fractures went onto union, except two participants in LISS group who had to be revised due to loss of reduction, in the early post-operative peroid. There were three nonunions in the same group. These required a re-operation. Further more, a LISS participant who had re-injured his distal femur (unrelated to LISS plate), was fixed with different implant. There was a single nonunion with the DCS group that needed revision surgery. There was one participant from each group who had drifted into varus. Neither required a re-operation. This translated into a 21% re-operation rate in the LISS system compared to 4% with the DCS device. Our data supports the use of the DCS system in the fixation of distal femur fractures (except Type C3} via a minimally invasive approach. The LISS implant seems to be technique dependent. In our centre, the LISS plate had been discontinued in favour of the DCP and
Background. Periprosthetic fracture fixation can be a difficult and complex procedure. The incidence of such fractures is increasing relative to the high prevalence of elderly patients with joint arthroplasty and osteoporosis. Locking plates were introduced for the management of complex periarticular fractures in osteoporotic bone, but there is little information on the use of these plates for the management of periprosthetic fractures. The purpose of this study was to review the early experience with these plates in managing complex Vancouver B1 and C periprosthetic fractures at our academic centre to determine the effectiveness in achieving union, and to identify any potential complications associated with their use. Methods. We evaluated the results of Vancouver B1 and type C periprosthetic fractures treated with Synthes