Advertisement for orthosearch.org.uk
Results 1 - 20 of 127
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 3 | Pages 429 - 432
1 May 1987
Middleton R Frost R

This paper describes the design, development and early surgical experience with a stereotactic device to allow closed retrieval and interchange of intramedullary rods in children with osteogenesis imperfecta. This relatively atraumatic procedure may allow more frequent rod interchange than with other techniques, lessening the likelihood of deformity and fracture in the unsupported skeleton when the bone has outgrown the intramedullary rod. The procedure was developed by design studies in vitro followed by intramedullary rodding of tibiae of New Zealand white rabbits. It has been used in children 12 times, in six tibiae and six femora: 11 rods have been successfully retrieved, with rod interchange in eight of these cases


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 3 | Pages 422 - 427
1 May 1989
Stockley I Bell M Sharrard W

We report the results of using 83 expanding intramedullary rods in 24 children with osteogenesis imperfecta after a mean follow-up of five years three months. In all, 62% of the rods have expanded after one primary operation. Thirty-four additional operations were necessary; 11 for the correction of rotation or angulation deformities and 23 for revision of the rod or T-piece. All these revisions were successful. Complications were more frequent in children who required very small rods. Problems with Bailey-Dubow rods led to the development of the Sheffield rod system; 17 bones treated with these rods are included in the series. Before surgery only eight of the 24 children were able to walk but at review 20 children were walking, 15 without walking aids. Elongating intramedullary rods should be available to all children with osteogenesis imperfecta as they improve walking capability, reduce the number of fractures, prevent deformity and allow integration of the child into society


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 64 - 64
1 Mar 2017
Oh B Cho W Cho H Lee G
Full Access

Purpose. Failure resulting from a recurrent infection in total knee arthroplasty (TKA) is a challenging problem. Knee arthrodesis is one treatment option, however fusion is not always successful, as there is huge bone defect. The authors reports a new arthrodesis technique that uses a bundle of flexible intramedullary rods and an antibiotic-loaded cement spacer. Methods. There were 13 cases of arthrodesis due to recurrent periprosthetic joint infection, which were performed by the first author (WS Cho) at Asan Medical Center in Seoul from 2005 to 2014. All previous prosthetic components were removed and cement was thoroughly excised using a small osteotome. Two stage operation was done in most of cases. After thorough debridement, antibiotics loaded cement was inserted in first stage, flexible intramedullary rods were inserted retrogradely in the femoral side with the knee in flexion under fluoroscopy guidance. After filling the femoral intramedullary canal, the rods were then driven back securely into the tibial medullary canal. We aimed for as much rod length as possible to maximize stability. After 6 weeks of first stage operation, the rods of the femoral and tibial sides were arranged such that they overlapped and interdigitated to maximize mechanical strength, maintain the limb length and keep the rotational alignment. The interdigitating rod ends were tightly fixed using two (or three) cerclage wires. Antibiotic-loaded cement was filled into the knee joint space so that the cement is fit to the irregular contour of the femur and tibia, which was resulted from the severe bone loss. Postoperatively, patients were allowed to weight bear as tolerated. Results. The procedure was successful in every cases with no evidence of rod or cement failure at least 1 year follow up. Also there was no recurrence of infection. Conclusion. Although this simple method was not for bony union, the authors could achieve stable knee joint without recurrence of infection


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 634 - 638
1 May 2011
Cho T Kim J Lee JW Lee K Park MS Yoo WJ Chung CY Choi IH

We investigated the fracture-free survival of long bones stabilised by a telescopic intramedullary rod (TIMR) in patients with osteogenesis imperfecta with respect to the remodelling status of fracture or osteotomy sites and TIMR regions, in order to identify risk factors for fracture. A total of 44 femora and 28 tibiae in 25 patients with a mean age of 5.0 years (1.9 to 10.5) at presentation were studied. There were six patients with Sillence type I, five with type III, 13 with type IV and one with type V osteogenesis imperfecta. All received bisphosphonate treatment at the same stage during the mean follow-up of 7.3 years (0.5 to 18.1). The fracture-free survival was estimated at 6.2 years (95% confidence interval 5.1 to 7.3) by Kaplan-Meier analysis. More than half the fracture or osteotomy sites remained in a less-remodelled state at the latest follow-up or time of fracture. Of the 33 fractures, 29 (87.9%) occurred in long bones containing a less-remodelled site, and these fractures were located at this site. The relative fracture risk at the rod tip was significantly greater than in any other TIMR region (p < 0.001), and this was higher in bone segments having a less-remodelled site. This study shows a persistent fracture risk in TIMR-stabilised long bones, especially at less-remodelled fracture or osteotomy sites and at the rod tip


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 28 - 28
1 Mar 2008
Aravindan S Kennedy J McGuinness A Taylor T
Full Access

High complication rates and technical difficulties of intramedullary fixation in children with osteogenesis imperfecta have prompted the modification of existing rod systems. The Sheffield telescoping intramedullary rod system was introduced to reduce the complications. It has a T-piece which is permanently fixed to prevent its separation and is expanded to reduce the migration. This study analyses the outcome of this rod system over a 12-year period in two specialist centres. Sixty rods were inserted in the lower limbs of 19 children with osteogenesis imperfecta. All children had multiple fractures of the bones before rod insertion. 39 rods were inserted into the femur, of which 3 were exchange and 4 revision procedures. 21 rods were inserted in the tibia. Eight children had intramedullary rodding of all the four lower limb long bones. The outcome was measured in terms of mobility status, incidence of refractures and rod-related complications. Our series demonstrates that there is significant reduction in refractures and improvement in the mobility status in children with osteogenesis imperfecta following intramedullary fixation. The frequent complication of T-piece separation and the need for reoperation has been overcome with the Sheffield modification of rod design. But the extracortical and metaphyseal migration of the rod continues to be a problem and further improvement in the design is desirable


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 5 | Pages 652 - 655
1 Nov 1984
Middleton R

Three cases of severe osteogenesis imperfecta are reported. Each was treated by closed intramedullary rodding, combined with osteoclasis to correct deformity. Operation was performed within a few months of birth. Both tibiae and both femora were stabilised in one operation, using x-ray image intensification to monitor placement of the rods. The technique used to insert the rods is described. The procedure appeared to be entirely satisfactory in reducing the incidence of fractures and it allowed the affected infants to be handled much more easily


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 6 | Pages 1073 - 1075
1 Nov 1990
Fern E Stockley I Bell M

Five patients with Boyd type II congenital pseudarthrosis of the tibia underwent excision of the pseudarthrosis and double onlay bone grafting. Stability was maintained by extending intramedullary rods. Clinical union was achieved in all cases at a mean of 8.6 months (range six to 11). The rods extended by 15.7% (range 2% to 31.4%) as growth occurred. One rod was removed because of infection and a vascularised free fibular graft was subsequently performed. The extending rods provided stability while union occurred and did not require revision as the legs grew. The rods can be removed easily and have not jeopardized further surgical options


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 999 - 1004
1 Nov 1998
Wilkinson JM Scott BW Clarke AM Bell MJ

The Sheffield Expanding Intramedullary Rod System was developed after experiencing problems with existing rod systems in the management of osteogenesis imperfecta. Between 1986 and 1996 we treated 74 bones in the lower limb in 28 children at a median follow-up of 5.25 years. We have reviewed 24 children with a total of 60 rods. Before surgery, all children had had multiple fractures of the lower limb. At review eight patients had experienced no further fractures, but three had suffered five or more subsequently. Before initial stabilisation, 15 children had never walked, and only three (13%) used walking as their main means of mobility. After surgery, half of those who showed motor arrest were able to walk (p = 0.016). The number of patients able to walk, with or without aids, increased to 17 (p = 0.0001). We have experienced no evidence of epiphyseal damage after the procedure, and complication rates requiring rod exchange have been low (7%)


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 138 - 138
1 Feb 2003
Aravindan S Kennedy JG McGuinness AJ Taylor T
Full Access

High complication rates and technical difficulties of intramedullary fixation in children with osteogenesis imperfecta has prompted the modification of existing rod systems. The Sheffield telescoping intramedullary road has T-piece which is permanently fixed and is expanded to reduce metaphyseal migration. This study analyses the outcome of this rod system over an 11 year period in two tertiary referral hospitals. 60 rods were inserted in the lower limbs of 19 children with osteogenesis imperfecta. All children had multiple fractures of the bones before rod insertion. 39 rods were inserted into femur, of which 3 were exchange and 4 revision procedures. 21 rods were inserted into tibia. Eight children had intramedullary rodding of both femur and tibia bilaterally. The outcome was measured in terms of incidence of refractures, mobility status, functional improvement and rod related complications. Our series demonstrates that there is significant reduction in refractures and improvement in the functional status of children with osteogenesis imperfecta following intramedullary fixation. The frequent complication of T-piece separation and the need for re-operation has been overcome with Sheffield modification of rod design. But the incidence of the rod, particularly at the proximal end of femur remains high and further improvement in the design is desirable


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 37 - 37
1 May 2012
N. N J.D. B J.M. W J.A. F M.J. B
Full Access

Elongating rods have been used in the management of Osteogenesis Imperfecta (OI) for the last 50 years; complication rates have been high in many reviews of available techniques.

The functional outcomes and complications of a cohort of 22 Osteogenesis Imperfecta patients treated with 66 Sheffield Telescopic Intramedullary Rods at an average of 19 years post-initial surgery are analysed. The revision rate was 35% for any reason, 20% excluding revisions for rods separating due to growth. Re-operation other than revisions occurred in 10 rods (15%). Mobility was significantly better in the initial post-operative period (p=0.0015), this difference maintained in adulthood (p=0.0077). Back pain was the most frequent symptom. Symptoms related to the insertion technique across the knee and ankle were rare but those related to femoral trochanteric entry were common. Physeal damage following surgery was not experienced and all rods elongated.

All patients were satisfied with the outcome of their surgeries. SF-36 scores were significantly different for physical functioning domains, social functioning and vitality in comparison to normal population values, but comparable to other studies of OI.

The outcomes of this technique are satisfactory in adulthood; re-operation rates are high but related mainly to outgrowing the rods. Concerns regarding insertion with this fixed device at the knee and ankle are not founded, although proximal femoral fixation remains a problem.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 2 | Pages 227 - 232
1 Mar 1984
Lang-Stevenson A Sharrard W

The results and complications of the use of Bailey-Dubow extensible rods in 28 lower limb bones of 10 patients suffering from osteogenesis imperfecta are reviewed. Twenty-eight operations were for the primary insertion of the rods into the femur or tibia; a further nine operations were needed for the treatment of complications. These complications included 10 instances of proximal migration of the distal end of the rod, one of incorrect placement in the proximal femur, four instances of loosening of a T-piece and three of infection about a rod, two of these being in one child. Most complications arose from technical faults at insertion. The details of technique which have evolved from experience are described. Only one fracture has occurred in a bone after correct placement of a rod. Of the 10 patients, seven of whom had never walked before, seven were able to walk and two others had achieved walking, but were under treatment for complications at the time of review. There was no evidence of damage to growth epiphyses. The greater technical complexity of insertion of Bailey-Dubow rods is well justified by the results obtained when they are correctly applied.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 420 - 420
1 Oct 2006
Dallari D Girolami M Mignani G Pignatti G Stagni C Vaccarisi D
Full Access

From January 2003 to December 2004, 160 consecutive intertrochanteric hip fractures has been treated at the Orthopaedic Rizzoli Institute by a new short intra-medullary rod, which can be distally locked, combined with two sliding screws that insert into the femoral neck and head. The rod is an undersized, titan one. It can be inserted percutaneously.

Fractures were classified pre-operatively according to stability and post-operatively according to the type of operative reduction.

The failure rate and post-operative stability were then compared according to the type of fracture and to the quality of operative reduction.

Results indicate that the pre-operative fracture classification is a significant determinant of post-operative stability. The type of operative reduction was not as significant a determinant of post-operative stability, but an anatomical reduction gives better clinical results.

Overall results shows that stable fractures has always healed and only minor complications has been observed. Unstable fractures has a percentage of drawbacks of 1.5% (3 in 160 pts) due to a wrong screw positioning ( 2 proximal and 1 distal ).

Three patients died in the early post-operative period due to cardiac failure.

No intraoperative fracture, no displacement of the fracture site and no “cut out” were observed.


The Bone & Joint Journal
Vol. 106-B, Issue 12 | Pages 1485 - 1492
1 Dec 2024
Terek RM

Aims

The aim of the LightFix Trial was to evaluate the clinical outcomes for one year after the treatment of impending and completed pathological fractures of the humerus using the IlluminOss System (IS), and to analyze the performance of this device.

Methods

A total of 81 patients with an impending or completed pathological fracture were enrolled in a multicentre, open label single cohort study and treated with IS. Inclusion criteria were visual analogue scale (VAS) Pain Scores > 60 mm/100 mm and Mirels’ Score ≥ 8. VAS pain, Musculoskeletal Tumor Society (MSTS) Upper Limb Function, and The European Organization for Research and Treatment of Cancer QoL Group Bone Metastases Module (QLQ-BM22) scores were all normalized to 100, and radiographs were obtained at baseline and at 14, 30, 90, 180, and 360 days postoperatively.


Bone & Joint Open
Vol. 5, Issue 11 | Pages 999 - 1003
7 Nov 2024
Tan SHS Pei Y Chan CX Pang KC Lim AKS Hui JH Ning B

Aims. Congenital pseudarthrosis of the tibia (CPT) has traditionally been a difficult condition to treat, with high complication rates, including nonunion, refractures, malalignment, and leg length discrepancy. Surgical approaches to treatment of CPT include intramedullary rodding, external fixation, combined intramedullary rodding and external fixation, vascularized fibular graft, and most recently cross-union. The current study aims to compare the outcomes and complication rates of cross-union versus other surgical approaches as an index surgery for the management of CPT. Our hypothesis was that a good index surgery for CPT achieves union and minimizes complications such as refractures and limb length discrepancy. Methods. A multicentre study was conducted involving two institutions in Singapore and China. All patients with CPT who were surgically managed between January 2009 and December 2021 were included. The patients were divided based on their index surgery. Group 1 included patients who underwent excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for their index surgery. Group 2 included patients who underwent all other surgical procedures for their index surgery, including excision of hamartoma, intramedullary rodding, and/or external fixation, without cross-union of the tibia and fibula. Comparisons of the rates of union, refracture, limb length discrepancy, reoperations, and other complications were performed between the two groups. Results. A total of 36 patients were included in the study. Group 1 comprised 13 patients, while Group 2 comprised 23 patients. The mean age at index surgery was four years (1 to 13). The mean duration of follow-up was 4.85 years (1.75 to 14). All patients in Group 1 achieved bony union at a mean of three months (1.5 to 4), but ten of 23 patients in Group 2 had nonunion of the pseudarthrosis (p = 0.006). None of the patients in Group 1 had a refracture, while seven of 13 patients who achieved bony union in Group 2 suffered a refracture (p = 0.005). None of the patients in Group 1 had a limb length discrepancy of more than 2 cm, while ten of 23 patients in Group 2 have a limb length discrepancy of more than 2 cm (p = 0.006). In Group 1, four of 13 patients had a complication, while 16 of 23 patients in Group 2 had a complication (p = 0.004). Excluding removal of implants, four of 13 patients in Group 1 had to undergo additional surgery, while 18 of 23 patients in Group 2 had to undergo additional surgery following the index surgery (p = 0.011). Conclusion. A good index surgery of excision of hamartoma, cross-union of the tibia and fibula, autogenic iliac bone grafting, and internal fixation for CPT achieves union and minimizes complications such as refractures, limb length discrepancy, and need for additional surgeries


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 116 - 116
1 Jul 2002
Bachfischer K Gerdesmeyer L Mittelmeier W Gradinger R
Full Access

The cranial cup is now a standardised implant in acetabular revision surgery. In order to illustrate the positive results of a standardised implant in acetabular revision surgery in comparison to other possibilities of reconstruction, we analysed results of all data in our study group. Aseptic loosening of implants often causes segmental and cavitary acetabular deficiency. Experiences gained in radical tumour surgery with reconstruction by custommade endoprostheses induced the development of the cranial cup for revision total hip arthroplasty. This new cementless revision cup has an oval shape and a special cranial flap, as well as an intramedullary rod if necessary. This type of cranial cup has been used since 1993. From 9/97 to 1/99, we implanted 30 cranial cups in revision hip surgery and collected all data of these patients prospectively. Clinical and x-ray follow-up was documented on a regular basis. Acetabular deficiency occurred twice in type 1, five times in type 2, twenty-two times in type 3 and once in type 4. The AAOS D’Antonio score was used. Cranial cups were implanted without cranial flap in 10 cases, with cranial flap in 20 cases and once using the intramedullary rod additionally. Only 28 patients were included in our last examination because one patient had died and one was bedridden because of a reason other than the hip. The Harris hip score increased from an average of 32 points preoperatively to 63 points postoperatively. Twenty-one patients are satisfied or very satisfied with their surgery. Radiograph examinations showed an average inclination angle of 42.5° in all cranial cups. Up to now there have been complications in four patients who suffered luxations, but only one required a change of inlay. One intraoperative injury of the urinary bladder had to be revised later. Three implants showed a change of position in x-ray. One was the patient with the urinary bladder injury and possible septic loosening, the second was a patient with extreme osteoporosis, and the third was a patient who did not receive an intramedullary rod for a type 4 lesions. Currently, these three patients do not have any complaints. We have always achieved primary stability. Morselised bone autografts or bone substitute materials were used to fill remaining defects. An intramedullary rod should be used in pelvis discontinuity and is obligatory to achieve the necessary stability. Developed from the experiences of custom-made tumour endoprostheses, the cranial cup with all possible variations is an appropriate intraoperative variable implant in revision acetabular surgery


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_9 | Pages 17 - 17
1 Aug 2015
Hancock G Price K Giles S Fernandes J
Full Access

The aim of this study was to determine the effectiveness of intra-operative tranexamic acid in children with osteogenesis imperfecta, who have been shown to have increased bleeding tendency, in deformity correction surgery. We retrospectively reviewed all cases of lower limb intramedullary rodding in patients with osteogenesis imperfecta treated in our unit from 2000–2013 in whom a pre and post- operative full blood count was available (n=69). Case notes were reviewed and patients were grouped according to the use of tranexamic acid. Peri-operative change in haemoglobin (Hb), haematocrit (HCT) and requirement for blood transfusion was assessed. Of 69 operations performed, 62.3% were in female patients, 78.3% were femoral, and 43.5% were bilateral cases (19 femur, 11 tibia). In the non-tranexamic acid group there was a mean drop in Hb of 28.9 g/L (range 0–62), mean HCT drop of 8.8 (range 2.2–19.4) and 3 patients required red cell transfusion. In the tranexamic acid group there was a mean Hb drop of 22.5 g/L (range 1–49), mean HCT drop of 7.35 (range −0.8–16.7) and one patient required red cell transfusion. There was a significant decrease in Hb drop (p=0.0287) in the tranexamic acid group. Tranexamic acid seems to decrease the drop in haemoglobin during lower limb intramedullary rodding in patients with osteogenesis imperfecta, with little associated risk. Protocols should be established for future use a further review undertaken


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 27 - 27
1 Sep 2014
Oduah G Firth G Thandrayan K
Full Access

Introduction and Purpose of Study. Osteogenesis imperfecta (OI) is a bone metabolic disorder that results in multiple fractures and deformities in children. The management of these patients should be in highly specialised units were multi-disciplinary management is mandatory. The aims of this study were twofold: 1. To determine the incidence and pattern of fractures in this population. 2. To determine the type, outcomes and complications of surgical treatment in the same population. Methods. A retrospective audit of patients treated for OI at a tertiary academic Hospital, from January 2002 to December 2011 was done. Results. Fifty three patients with OI were seen in the period under review. The patients came from six South African provinces including two other African countries. The male to female ratio was 1:1. The majority of patients were classified as type III and type IV, 19 (36%) and 14 (26%) respectively. Twelve patients (23%) had a first degree relative with OI. All patients received bisphosphonate therapy intravenously except two who were on oral medication. Seventeen patients (33%) had associated kyphoscoliosis – none were treated surgically. The most common long bone fractures were of the midshaft femur (61 fractures) and tibia (35 fractures). Seventeen patients (32%) received intramedullary rodding of either femur or tibia. Surgery had to be repeated due to rod migration in nine long bones (29%). The most common complication of surgery was rod migration and peri-implant fracture. Conclusion. Long bone fractures of the femur and tibia were most common cause of morbidity. Intramedullary rodding is a safe and effective means of long bone fracture management in patients with OI


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 18 - 18
1 Sep 2014
Moolman C Dix-Peek S Mears S Hoffman E
Full Access

Aim. To determine the preferable treatment for congenital pseudarthrosis of the tibia, we retrospectively reviewed 19 patients (20 limbs) treated consecutively over a 22 year period (1988–2007). Fifteen were followed up to maturity. The patients were assessed for union, leg length discrepancy (LLD), ankle valgus, range of ankle movement and distal tibial physeal injury. Results. The median age at surgery was 3 years. At surgery nineteen of the tibiae had a dysplastic constriction with a fracture (Crawford II-C or Boyd II) lesion. To obtain union in the 20 tibiae, 29 procedures were done. Nine failed primarily and required a second procedure to obtain union. Older patients (≥ 5 years) had a significantly higher success rate. Excision, intramedullary rodding and bone graft (IMR) was done in 14 tibiae: 10 (71.4%) were successful. Six of 10 primary operations and all 4 secondary operations after a previous failed procedure were successful. Ipsilateral vascularized fibula transfer (IVFT) was successful in 5 tibiae (3 primary and 2 secondary). Ilizarov with bone transport only, failed in two patients. Ilizarov with excision, intramedullary rodding and bone graft with lengthening was successful in 2 of 5 cases (40%); two sustained fractures at the proximal lengthening site. A median leg length discrepancy (LLD) of 3 cms occurred post surgery which was treated with contralateral epiphysiodesis. At maturity 3 patients had a LLD of ≥ 2cms. Six limbs had ankle valgus and were treated with stapling and tibio-fibular syndesmosis. Decreased range of movement of the ankle (< 50%) occurred in 7 patients. Distal tibial physeal injury occurred in 4 patients and was associated with repeated rodding. Conclusion. We concluded that surgery should be delayed as long as possible. If there is adequate tibial purchase for the rod distally, IMR is the best option. If purchase is inadequate, Ilizarov with rodding will avoid ankle stiffness. Epiphysiodesis is preferable to lengthening because of the risk of fracture above the rod. IVFT is a good option as a secondary procedure. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 228 - 228
1 Mar 2010
Singh A Anderson G
Full Access

Intramedullary nailing is acknowledged as a safe and effective mode of treatment for many tibial fractures. Implant removal is frequently indicated either as an elective procedure following union or because of problems such as infection or delayed fracture union. It is therefore essential that intramedullary rod removal should be reasonably straightforward and atraumatic. We describe three cases in which bony growth into the implant has made rod removal either difficult or impossible. We include photographs of two removed implants with clearly visible areas of osseo-integration with bony growth into the cannulation through the interlocking holes as well as radiographs demonstrating the same phenomenon. The average time between insertion and removal was 16 months. In all cases an end cap had been used such that insertion of the extraction device was straightforward but for two patients nail removal was extremely difficult due to bone ingrowth and in the third patient the nail had to be left in-situ. All three implants were made of titanium and the patients were all active young males. The authors have never encountered this problem with steel rods and speculate that the osteointegrative property of titanium is the major causative factor. We suggest that unremoved intramedullary rods represent a major risk in fracture management and that close monitoring of these implants should be undertaken


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 209 - 209
1 Nov 2002
Tassawipas A Mokkhavesa S
Full Access

A cadaveric study was done to determine the relationship of intramedullary axis of femur and the anatomical landmarks of proximal femur. The sharp tipped intramedullary rod was placed in the medullary canal from the isthmus to the proximal femur in 20 adult femoral specimens. The point of exit was measured in relationship to the piriformis fossa, tip of greater tuberosity, and mid lesser tuberosity. The center of the femoral canal axis is 1.23 ± 0.92 cm superior and medial to the pirifomis fossa, and is located 1.55 ± 0.66 cm from greater tuberority and 5.21 ± 1.28 cm from mid lesser tuberosity. The clinical relevance of this study is that the starting point for closed antegrade intramedullary rod of the femur should be 1.2 cm superior and medial to piriformis fossa in order to avoid the difficulty and complications in intramedullary nailing