Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 512 - 512
1 Sep 2012
Zlowodzki M Armitage B Wijdicks C Kregor P Bruce L Cole P
Full Access

Introduction. The most common treatment options for fixation of osteoporotic distal femur fractures are retrograde nails and locking plates. There are proponents of more elastic titanium plates as well as more rigid steel plates; No clear superiority of one over the other has been established. We aimed to evaluate the mechanical differences between stainless steel and titanium locking plates in the fixation of distal femur fractures in osteoporotic bone. We hypothesized that due to its higher elasticity titanium locking plates can absorb more energy and are therefore less likely to “cut” into the bone compared to stainless steel locking plates resulting in improved metaphyseal osteoporotic fracture fixation. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Within each pair we randomized one femur to be fitted with a Less Invasive Stabilization System (LISS-Titanium locking plate) and one with a Distal Locking Condylar Plate (DLCP-Stainless steel locking plate). A fracture model simulating an AO 33-A3 fracture was created (extraarticular comminuted fracture) and specimens were subsequently subjected to step-wise cyclic axial loading to failure. We used an advanced three dimensional tracking system (Polhemus Fastrak) to monitor the movement of the distal fragment relative to the real time distal plate position allowing us to evaluate distal implant cut-out. Results. During cyclic testing, seven of the eight pairs of matched femurs, the DLCP failed before the LISS plate (p=0.03). All constructs were able to withstand cyclical loading up to 800N. The overall plastic deformation as measured by the displacement of the Instron crosshead experienced by the titanium plate constructs was significantly lower compared to the stainless steel plate construct: The plastic deformation of the LISS plates was 39% lower compared to the Locking Condylar plates after cycle testing at 400 Newtons and 70% lower at 800N. Furthermore during the 800N cycle testing the LISS plating system showed a significantly lower rate of plastic deformation not only for the entire bone-implant construct, but also between the plate and the distal fragment than the locking condylar plate (=less distal implant cut-out). Conclusions. The use of a more advanced three dimensional tracking system, fresh-frozen osteoporotic matched human specimen and the ability to test all constructs to failure allowed us a more thorough comparison of titanium versus stainless steel implants compared to previous studies. The titanium locking plates provided an overall superior fixation of osteoporotic distal femur fractures with less distal implant cut-out, a better elastic recoil, and a slower rate of residual plastic deformation


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 696 - 702
1 May 2016
Theologis AA Burch S Pekmezci M

Aims. We compared the accuracy, operating time and radiation exposure of the introduction of iliosacral screws using O-arm/Stealth Navigation and standard fluoroscopy. Materials and Methods. Iliosacral screws were introduced percutaneously into the first sacral body (S1) of ten human cadavers, four men and six women. The mean age was 77 years (58 to 85). Screws were introduced using a standard technique into the left side of S1 using C-Arm fluoroscopy and then into the right side using O-Arm/Stealth Navigation. The radiation was measured on the surgeon by dosimeters placed under a lead thyroid shield and apron, on a finger, a hat and on the cadavers. Results. There were no neuroforaminal breaches in either group. The set-up time for the O-Arm was significantly longer than for the C-Arm, while total time for placement of the screws was significantly shorter for the O-Arm than for the C-Arm (p = 0.001). The mean absorbed radiation dose during fluoroscopy was 1063 mRad (432.5 mRad to 4150 mRad). No radiation was detected on the surgeon during fluoroscopy, or when he left the room during the use of the O-Arm. The mean radiation detected on the cadavers was significantly higher in the O-Arm group (2710 mRem standard deviation (. sd. ) 1922) than during fluoroscopy (11.9 mRem . sd 14.8). (p < 0.01). Conclusion. O-Arm/Stealth Navigation allows for faster percutaneous placement of iliosacral screws in a radiation-free environment for surgeons, albeit with the same accuracy and significantly more radiation exposure to cadavers, when compared with standard fluoroscopy. Take home message: Placement of iliosacral screws with O-Arm/Stealth Navigation can be performed safely and effectively. Cite this article: Bone Joint J 2016;98-B:696–702


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_4 | Pages 1 - 1
1 May 2015
Davidson E White T Hall A
Full Access

Articular cartilage has very poor repair potential, however it has an extraordinary capacity to withstand physiological mechanical loads in an intact joint. The nature and extent of chondrocyte death in articular cartilage following many forms of injury (trephine, scalpel, osteotome, sutures and drilling) has been characterised, but the ability to bear mechanical injury from iatrogenic surgical interventions is still unknown. A standard arthroscopic probe was moved at varying physiological pressures along the articular cartilage of joint before staining with fluorescent dyes to allow live/dead cell imaging using laser confocal scanning microscopy and imaging software, Image J. Bovine metatarsal phalangeal joints and fresh human cadaveric femoral condyles were used. The probe caused statistically significant chondrocyte death in bovine cartilage (p=0.02). Mild pressure 5% cell death, moderate (standard arthroscopic technique pressure) 22% and severe pressure 38%. A similar result was seen in human tissue with 24% cell death at moderate pressure compared to a control (p=0.0699). The widely assumed benign arthroscopic probe produces significant cell death in articular cartilage when used at standard operating pressures


The Bone & Joint Journal
Vol. 96-B, Issue 3 | Pages 385 - 389
1 Mar 2014
Attal R Maestri V Doshi HK Onder U Smekal V Blauth M Schmoelz W

Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction. Cite this article: Bone Joint J 2014;96-B:385–9


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_8 | Pages 15 - 15
1 Feb 2013
Ramasamy A Masouros S Newell N Bonner T West A Hill A Clasper J Bull A
Full Access

Current military conflicts are characterised by the use of the Improvised Explosive Device (IED). Improvements in personal protection, medical care and evacuation logistics have resulted in increasing numbers of casualties surviving with complex musculoskeletal injuries, often leading to life-long disability. Thus, there exists an urgent requirement to investigate the mechanism of extremity injury caused by these devices in order to develop mitigation strategies. In addition, the wounds of war are no longer restricted to the battlefield; similar injuries can be witnessed in civilian centres following a terrorist attack. Key to mitigating such injuries is the ability to deconstruct the complexities of an explosive event into a controlled, laboratory-based environment. In this study, an anti-vehicle underbelly injury simulator, capable of recreating in the laboratory the impulse from an anti-vehicle (AV) explosion, is presented and characterised. Tests were then conducted to assess the simulator's ability to interact with human cadaveric legs. Two mounting conditions were assessed, simulating a typical seated and standing vehicle passenger using instrumented cadaveric lower limbs. This experimental device, will now allow us (a) to gain comprehensive understanding of the load-transfer mechanisms through the lower limb, (b) to characterise the dissipating capacity of mitigation technologies, and (c) to assess the biofidelity of surrogates


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 393 - 393
1 Sep 2012
Zlowodzki M Wijdicks C Armitage B Cole P
Full Access

Introduction. Femoral neck fractures are a large clinical and economical problem. One of the most common fixation options for femoral neck fractures are multiple cancellous screws. A previous clinical study has shown the lack of washers to be the single largest predictor of fixation failure in the treatment of femoral neck fractures with cancellous screws. This finding was somewhat surprising as washers do not prevent the screws from backing out and do not provide any increase resistance to varus collapse. Therefore a follow-up biomechanical study was designed to test this observation. The purpose was to evaluate the maximal insertional torque of screws in osteoporotic bone with and without washers. We hypothesized that the lateral cortex of an osteoporotic proximal femur does not provide sufficient counter resistance for the screw heads to obtain maximum torque upon screw insertion in the femoral head and that the use of washers would increase screw purchase by providing a larger rigid surface area and subsequent higher counter resistance thereby allowing a higher maximal screw insertion torque. Methods. We used eight matched pairs of osteoporotic fresh-frozen human cadaveric femurs (age >70 years, all female). Two screws each were inserted in each femur either with or without a washer and maximal insertional torque was measured using a 50 Nm torque transducer. The testing was performed using a customized device which allowed the torque transducer to apply a constant axial force and torque speed to the screws. A paired Student's t-test was used to compare the maximal screw insertional torque of screws with washers versus screws without washers in matched pairs. Results. Fifteen out of 16 times the maximal screw insertional torque was higher when a washer was used. The average maximal torque with a washer was 5.1 Newtonmeter (Nm) compared to 3.1 Nm without a washer (p<0.001). Conclusion. We conclude that the addition of washers increases the maximal insertion torque of cancellous screws in the treatment of osteoporotic femoral neck fractures by providing counter resistance to the screw heads at an otherwise weak lateral cortex. We have demonstrated that the washer prevents the screw heads from penetrating the lateral cortex and provides for an improved purchase of the screws in the femoral head. As a clinical reference value for interpretation of this data, the limit of torque limiting screw drivers used with locking plates is set between 4 and 6 Nm. Therefore the difference in insertion torques likely represents clinically relevant values. Since there is no apparent disadvantage in the use of washers and they are inexpensive and readily available even in less developed countries, we advocate for their routine use until larger clinical studies disprove their efficacy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 284 - 284
1 Sep 2012
Wendlandt R Schrader S Schulz A Spuck S Jürgens C Tronnier V
Full Access

Introduction. The degeneration of the adjacent segment in lumbar spine with spondylodesis is well known, though the exact incidence and the mechanism is not clear. Several implants with semi rigid or dynamic behavior are available to reduce the biomechanical loads and to prevent an adjacent segment disease (ASD). Randomized controlled trials are not published. We investigated the biomechanical influence of dynamic and semi rigid implants on the adjacent segment in cadaver lumbar spine with monosegmental fusion (MF). Materials and Methods. 14 fresh cadaver lumbar spines were prepared; capsules and ligaments were kept intact. Pure rotanional moments of ±7.5 Nm were applied with a Zwick 1456 universal testing machine without preload in lateral bending and flexion/extension. The intradiscal pressure (IDP) and the range of motion (ROM) were measured in the segments L2/3 and L3/4 in following situations: in the native spine, monosegmental fusion L4/5 (MF), MF with dynamic rod to L3/4 (Dynabolt), MF with interspinous implant L3/4 (Coflex), and semi rigid fusion with PEEK rod (CD Horizon Legacy) L3-L5. Results. Under flexion load all implants reduced the IDP of segment L2/L3, whereas the IDP in the segment L3/4 was increased using interspinous implants in comparison to the other groups. The IDP was reduced in extension in both segments for all semi rigid or dynamic implants. Compared under extension to the native spine the MF had no influence on the IDP of the adjacent disc. The rod instrumentation (Dynabolt, PEEK rod) lead to a decreased IDP in lateral bending tests. The ROM in L3 was reduced in all groups compared to the native spine. The dynamic and semi rigid stabilization in the segment L3/4 limited the ROM more than the MF. Discussion. The MF reduced the ROM in all directions, whereas the IDP of the adjacent segment remained unaffected. The support of the adjacent segment by semi rigid and dynamic implants decreased the IDP of both segments in extension mainly. This fact is an agreement with other studies. Compared to our data, no significant effect on the adjacent levels was observed. Interestingly, in our study, the IDP of the adjacent segment is unaffected by MF. The biomechanical influence in the view of an ASD could be comprehended, but is not completely clear. The fact of persistent IDP in the adjacent segment suggests that MF has a lower effect on the adjacent segment degeneration as presumed. Biomechanical studies with human cadaver lumbar spines are limited and depend on age and degenerative situation. The effect on supporting implants on adjacent segment disease in lumbar spine surgery has to be investigated in clinical long term studies


Bone & Joint Open
Vol. 1, Issue 5 | Pages 103 - 114
13 May 2020
James HK Gregory RJH Tennent D Pattison GTR Fisher JD Griffin DR

Aims

The primary aim of the survey was to map the current provision of simulation training within UK and Republic of Ireland (RoI) trauma and orthopaedic (T&O) specialist training programmes to inform future design of a simulation based-curriculum. The secondary aims were to characterize; the types of simulation offered to trainees by stage of training, the sources of funding for simulation, the barriers to providing simulation in training, and to measure current research activity assessing the educational impact of simulation.

Methods

The development of the survey was a collaborative effort between the authors and the British Orthopaedic Association Simulation Group. The survey items were embedded in the Performance and Opportunity Dashboard, which annually audits quality in training across several domains on behalf of the Speciality Advisory Committee (SAC). The survey was sent via email to the 30 training programme directors in March 2019. Data were retrieved and analyzed at the Warwick Clinical Trials Unit, UK.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 530 - 538
1 Apr 2020
Rollick NC Gadinsky NE Klinger CE Kubik JF Dyke JP Helfet DL Wellman DS

Aims

Dual plating of distal femoral fractures with medial and lateral implants has been performed to improve construct mechanics and alignment, in cases where isolated lateral plating would be insufficient. This may potentially compromise vascularity, paradoxically impairing healing. This study investigates effects of single versus dual plating on distal femoral vascularity.

Methods

A total of eight cadaveric lower limb pairs were arbitrarily assigned to either 1) isolated lateral plating, or 2) lateral and medial plating of the distal femur, with four specimens per group. Contralateral limbs served as matched controls. Pre- and post-contrast MRI was performed to quantify signal intensity enhancement in the distal femur. Further evaluation of intraosseous vascularity was done with barium sulphate infusion with CT scan imaging. Specimens were then injected with latex medium and dissection was completed to assess extraosseous vasculature.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this.

The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture.

A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test.

The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence.

This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor.

Cite this article: Bone Joint J 2014;96-B:1378–84.


Bone & Joint Research
Vol. 1, Issue 6 | Pages 118 - 124
1 Jun 2012
Grawe B Le T Williamson S Archdeacon A Zardiackas L

Objectives

We aimed to further evaluate the biomechanical characteristics of two locking screws versus three standard bicortical screws in synthetic models of normal and osteoporotic bone.

Methods

Synthetic tubular bone models representing normal bone density and osteoporotic bone density were used. Artificial fracture gaps of 1 cm were created in each specimen before fixation with one of two constructs: 1) two locking screws using a five-hole locking compression plate (LCP) plate; or 2) three non-locking screws with a seven-hole LCP plate across each side of the fracture gap. The stiffness, maximum displacement, mode of failure and number of cycles to failure were recorded under progressive cyclic torsional and eccentric axial loading.