Advertisement for orthosearch.org.uk
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 9 - 9
1 Mar 2013
Okoro T Maddison P Andrew J Lemmey A
Full Access

Introduction. Late (commenced 6 months to 4 years post-op) home-based progressive resistance training programs are proven to improve muscle strength and function after total hip replacement (THR). This study assessed whether early (commenced < 1 week post-op) HBPRT post-THR improves muscle mass, strength and function relative to routine physiotherapy rehabilitation (RPR) at up to 12 months follow up. Methods. Prospective single blind randomized controlled study performed after ethical approval. 50 patients randomised to 6 week HBPRT (n=26) or RPR (n=24) postoperatively. Maximal voluntary contraction of the operated leg quadriceps in (MVCOLQ) in Newtons (N), sit to stands in 30 seconds (ST, number of repetitions), and the lean mass in grams of the operated leg (LM) were assessed preoperatively and at intervals up to 12 months postoperatively. Mixed model repeated measures ANOVA was used for statistical analysis. Results. With loss to follow up, 35 patients; HBPRT n=20 (males n=9, females n=11) and RPR n=15 (males n=6, females n=9); were analyzed preoperatively with 26 patients (HBPRT n=13, RPR n=13) completing 12 month follow up. There was no effect in the mixed model repeated measures ANOVA for randomization into either HBPRT or RPR for MVCOLQ (F=0.065, p=0.800), ST (F=0.255, p=0.617) or LM (F=0.849, p=0.364). Statistically significant improvement over time was obtained for MCVOLQ (F=21.519, p=0.002) and ST (F=41.895, p=0.003) but LM remained unchanged (F=0.003, p=0.954). Conclusions. Early HBPRT has no additional benefit when compared to RPR post-THR. Additional functional gain post-THR is possible with HBPRT only when it is applied late


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 9 - 9
4 Apr 2023
Fridberg M Annadatha S Hua Q Jensen T Liu J Kold S Rahbek O Shen M Ghaffari A
Full Access

To detect early signs of infection infrared thermography has been suggested to provide quantitative information. Our vision is to invent a pin site infection thermographic surveillance tool for patients at home. A preliminary step to this goal is the aim of this study, to automate the process of locating the pin and detecting the pin sites in thermal images efficiently, exactly, and reliably for extracting pin site temperatures.

A total of 1708 pin sites was investigated with Thermography and augmented by 9 different methods in to totally 10.409 images. The dataset was divided into a training set (n=8325), a validation set (n=1040), and a test set (n=1044) of images. The Pin Detection Model (PDM) was developed as follows: A You Only Look Once (YOLOv5) based object detection model with a Complete Detection Intersection over Union (CDIoU), it was pre-trained and finetuned by the through transfer learning. The basic performance of the YOLOv5 with CDIoU model was compared with other conventional models (FCOS and YOLOv4) for deep and transition learning to improve performance and precision. Maximum Temperature Extraction (MTE) Based on Region of Interest (ROI) for all pin sites was generated by the model. Inference of MTE using PDM with infected and un-infected datasets was investigated.

An automatic tool that can identify and annotate pin sites on conventional images using bounding boxes was established. The bounding box was transferred to the infrared image. The PMD algorithm was built on YOLOv5 with CDIoU and has a precision of 0.976. The model offers the pin site detection in 1.8 milliseconds. The thermal data from ROI at the pin site was automatically extracted.

These results enable automatic pin site annotation on thermography. The model tracks the correlation between temperature and infection from the detected pin sites and demonstrates it is a promising tool for automatic pin site detection and maximum temperature extraction for further infection studies. Our work for automatic pin site annotation on thermography paves the way for future research on infection assessment using thermography.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 53 - 53
14 Nov 2024
Fridberg M Rahbek O Husum H Bafor A Duch K Iobst C Kold S
Full Access

Introduction. Patients with external fixators are at risk of pin site infection. A more objective assessment of possible pin site infection is warranted, particularly for future home-based monitoring of pin sites. The aim was to determine if thermography can detect signs of inflammation around pin sites by 1) Establishing a maximum temperature cut-off value 2) Investigating the correlation between local temperature and visual signs of inflammation 3) Adjust for anatomical location and ambient room temperature. Method. This was a cross-sectional international multi-center study following STROBE guidelines. All patients with external ring-fixators scheduled for a visit in the out-patient clinic were eligible. Visual signs of inflammation were categorized using the Modified Gordon classification System (MGS, simplified sMGS). Thermographic imaging was done with an infrared camera (FLIR T540) and the maximum temperature within the ROI (MaxTp) was the primary outcome measure. Sample size and reliability were estimated. Cohen-Kappa, ROC-curve/AUC and Poisson regression were used for statistical analysis. Result. Data from 1970 pin sites were included. Inter-rater reliability of MGS was Kappa=0.79 and for MaxTp ICC=0.99 (95%CI: 0.99;0.99). Overall, a tendency of rising temperature with increasing sMGS was seen. The difference between sMGS=0 and sMGS>0 was significant. The performance of MaxTp as a screening tool to detect inflammation was reasonable with an AUC of 0.71 (95% CI: 0.65-0.76). The empirically optimal cut-off value was 34.1°C (Sensitivity=65%, Specificity=72%, Positive predictive value=23%, Negative Predictive value=94%). A 1°C increase in MaxTp increased the RR of visual signs of inflammation by a factor 1.5 (95% CI: 1.3; 1.7). Conclusion. We found a clinical positive association between the temperature at the pin site measured with thermography and visual signs of inflammation. The empirically optimal temperature cut-off value for inflammation screening was 34.1°C. Thermography may be a promising tool for a for a future point of care technology


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 75 - 75
14 Nov 2024
Khalid T Shlomo YB Bertram W Culliford L enderson E Jepson M Johnson E Palmer S Whitehouse M Wylde V
Full Access

Introduction. Approximately 20-25% of patients having joint replacement in the UK have moderate-severe frailty. Frailty is associated with poorer outcomes after joint replacement. Targeting frailty pre-operatively with exercise and protein supplementation could improve post-operative outcomes. Prior to conducting a randomised controlled trial (RCT), a feasibility study was necessary to inform trial design and delivery. Method. We conducted a randomised feasibility study with embedded qualitative work. Patients aged ≥65 years, frail and undergoing THR or TKR were recruited from three UK hospitals. Participants were randomly allocated on a 1:1 ratio to the intervention or usual care group. The intervention group had a 1:1 appointment with a physiotherapist and were provided with a home-based, tailored daily exercise programme and a daily protein supplement for 12 weeks before their operation, supported by six telephone calls from a physiotherapist. Questionnaires were administered at baseline and 12 weeks after randomisation. Interviews were conducted with 19 patients. Feasibility outcomes were eligibility and recruitment rates, intervention adherence, and acceptability of the trial and the intervention. Result. 411 patients were sent a screening pack. Of the 168 patients who returned a screening questionnaire, 79 were eligible and consented to participate, and 64 were randomised. Of the 33 participants randomised to the intervention, 26 attended the intervention appointment. Eighteen participants (69%) received all six intervention follow-up telephone calls. Nineteen participants completed an intervention adherence log; 13 (68%) adhered to the exercise programme and 11 (58%) adhered to the protein supplementation. The overall retention rate was 86% at 12 weeks. The 12-week follow-up questionnaire was returned by 84% of participants who were sent a questionnaire. Interviews found that the trial and intervention were generally acceptable, but areas of potential improvements were identified. Conclusion. This study demonstrated that a larger study is possible and has identified improvements to optimise the design of a RCT


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 34 - 34
1 Nov 2021
Larsen JB Østergaard HK Thillemann TM Falstie-Jensen T Reimer L Noe S Jensen SL Mechlenburg I
Full Access

Introduction and Objective. Only few studies have investigated the outcome of exercises in patients with glenohumeral osteoarthritis (OA) or rotator cuff tear arthropathy (CTA), and furthermore often excluded patients with a severe degree of OA. Several studies including a Cochrane review have suggested the need for trials comparing shoulder arthroplasty to non-surgical treatments. Before initiation of such a trial, the feasibility of progressive shoulder exercises (PSE) in patients, who are eligible for shoulder arthroplasty should be investigated. The aim was to investigate whether 12 weeks of PSE is feasible in patients with OA or CTA eligible for shoulder arthroplasty. Moreover, to report changes in shoulder function and range of motion (ROM) following the exercise program. Materials and Methods. Eighteen patients (11 women, 14 OA), mean age 70 years (range 57–80), performed 12 weeks of PSE with 1 weekly physiotherapist-supervised and 2 weekly home-based sessions. Feasibility was measured by drop-out rate, adverse events, pain and adherence to PSE. Patients completed Western Ontario Osteoarthritis of the Shoulder (WOOS) score and Disabilities of the Arm, Shoulder and Hand (DASH). Results. Two patients dropped out and no adverse events were observed. Sixteen patients (89%) had high adherence to the physiotherapist-supervised sessions. Acceptable pain levels were reported. WOOS improved mean 23 points (95%CI:13;33), and DASH improved mean 13 points (95%CI:6;19). Conclusions. PSE is feasible, safe and may improve shoulder pain, function and ROM in patients with OA or CTA eligible for shoulder arthroplasty. PSE is a feasible treatment that may be compared with arthroplasty in a RCT setting


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 103 - 103
1 Nov 2021
Brown O Hu L Demetriou C Smith T Hing C
Full Access

Introduction and Objective. Kinesiophobia, the fear of physical movement and activity related to injury vulnerability, has been linked to sub-optimal outcomes following total knee replacement (TKR). This systematic review has two aims: to define the relationship between kinesiophobia and functional outcomes, pain and range of motion following TKR, and to evaluate published treatments for kinesiophobia following TKR. Materials and Methods. A primary search was performed in March 2020. English-language studies recruiting adult primary TKR patients, using the Tampa Scale of Kinesiophobia (TSK) were included. Study quality was assessed using the Newcastle Ottawa Scale for cohort or case control studies, and the Cochrane Collaboration Risk of Bias tool for randomised controlled trials. Results. All thirteen included papers (82 identified) showed adequately low risk of methodological bias. TSK1 (activity avoidance) correlated with WOMAC functional score at 12 months in three studies (r=0.20 p<0.05, R=0.317 p=0.001, and correlation coefficient 0.197 p=0.005). TSK score significantly correlated with mean active range of motion (ROM) at six months (105.33 (SD=12.34) vs 85.53 (SD=14.77) p=0.000) post-operation. Three post-operative interventions improved TSK score vs control following TKR: a home-based functional exercise programme (TSK −14.30 (SD=0.80) vs −2.10 (SD=0.80) p<0.001)), an outpatient CBT programme (TSK 27.76 (SD=4.56) vs 36.54 (SD=3.58), and video-based psychological treatment (TSK 24 (SD=5) vs 29 (SD=5) p<0.01). Conclusions. Kinesiophobia negatively affects functional outcomes up until one year post-operatively, while active ROM is reduced up to six months post procedure. Post-operative functional and psychological interventions can improve kinesiophobia following TKR


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 50 - 50
1 Nov 2021
Rytoft L Frost MW Rahbek O Shen M Duch K Kold S
Full Access

Introduction and Objective. Home-based monitoring of fracture healing has the potential of reducing routine follow-up and improve personalized fracture care. Implantable sensors measuring electrical impedance might detect changes in the electrical current as the fracture heals. The aim was to investigate whether electrical impedance correlated with radiographic fracture healing. Materials and Methods. Eighteen rabbits were subjected to a tibial osteotomy that was stabilized with an external fixator. Two electrodes were positioned, one electrode placed within the medullary cavity and the other on the lateral cortex, both three millimeters from the osteotomy site. Transverse electrical impedance was measured daily across the fracture site at a frequency range of 5 Hz to 1 MHz using an Analog Discovery 2 Oscilloscope with Impedance Analyzer. Biweekly x-rays were taken and analyzed blinded using a modified anterior-posterior (AP) radiographic union score of the tibia (RUST). Each animal served as its own control by performing repeated measurements from time zero until the end of follow-up. Results. At 5 Hz measurements, a linear mixed model revealed an average impedance at day zero of 10670 +/− 272 Ohm (p<0.001) and a change in impedance from day 0 to day 7 of −3330 +/− 152 (p<0.001). The slope from day 0–7 was estimated as −548.6 +/− 26 (p<0.001) and was steeper than the slope after day 7 which was estimated to −85.6 +/− 4 (p<0.001). This indicates that the impedance decreased quicker before day 7 and slower after day 7. The coefficient of variation for difference between RUST scores, from double intra-rater measurements of 15 radiographs with a minimum of 22 days between, was 1.3. Spearman's correlation coefficient between impedance and RUST score at the 5 Hz was −0.75 (p<0.001). Conclusions. This osteotomy model showed that the electrical impedance can be measured in vivo at a distance from the fracture site with a consistent change in impedance over time. This is the first study to demonstrate a significant correlation between increasing radiographic union score and decreasing impedance. Further studies are warranted to investigate how these new and important results can further be translated into larger animal studies


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 17 - 17
1 Dec 2020
Frost MW
Full Access

Electrical impedance spectroscopy measurements might be used for real-time monitoring of bone healing. Differences in electrical characteristics of different tissues during fracture healing can provide information of the tissue composition within the fracture region. This concept embraces the digital revolution of orthopaedics allowing for a sensor-based and home-based monitoring of bone healing. Furthermore, real-time monitoring will allow individualized and timely treatment adjustments to prevent bone healing complications. However, electrodes must be placed at a distance to the fracture site in order not to interfere with bone healing. Therefore, we investigated whether longitudinal and transverse electrical impedance measurements from electrodes placed at a distance to the bone defect can detect differences between intact bone and bone defects in vivo. Approval was granted from the Inspectorate of the Animal Experimentation under the Danish Ministry of Justice. Six rabbits were anaesthetized and had both tibias subjected to an osteotomy protocol where first the medial, then the lateral, and final the posterior cortex were removed resulting in a complete 2 mm bone defect. Electrical impedance was measured prior to and after each step of the osteotomy protocol. Recordings were obtained at different frequencies (10 Hz to 1 MHz) from an inner electrode placed into the medullary canal and two different electrodes placed extracortical on the lateral and posterior bone with a distance of 5 mm to the defect. For each rabbit, one tibia had measurements with a free inner electrode and the other tibia had measurements both with a nail and an isolated nail. For all tibias, the intact bone resulted in higher impedance compared with the complete defect, and this difference was most pronounced in the frequency range of 1 kHz to 100 kHz. This applied for all types of internal electrodes including electrode, nail, isolated nail. The isolated nail showed the biggest impedance difference between the intact bone and the complete defect. Incomplete bone defects had lower impedance compared with intact bone, but no consistent pattern for differences in impedance was observed between the different applied defects. Consistent impedance differences between intact bone and complete defects were detected in-vivo in rabbits. Further research is needed to explore whether the presented method of electrical impedance measurements can be used to characterize bone healing over time


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 25 - 25
1 Jan 2019
Jones P Woodgate S Williams D Biggs P Nicholas K Button K Corcoran P Holt C
Full Access

Whilst home-based exercise rehabilitation plays a key role in determining patient outcomes following orthopaedic intervention (e.g. total knee replacement), it is very challenging for clinicians to objectively monitor patient progress, attribute functional improvement (or lack of) to adherence/non-adherence and ultimately prescribe personalised interventions. This research aimed to identify whether 4 knee rehabilitation exercises could be objectively distinguished from each other using lower body inertial measurement units (IMUs) and principle components analysis (PCA) in the hope to facilitate objective home monitoring of exercise rehabilitation. 5 healthy participants performed 4 repetitions of 4 exercises (knee flexion in sitting, knee extension, single leg step down and sit to stand) whilst wearing lower body IMU sensors (Xsens, Holland; sampling at 60 Hz). Anthropometric measurements and a static calibration were combined to create the biomechanical model, with 3D hip, knee and ankle angles computed using the Euler sequence ZXY. PCA was performed on time normalised (101 points) 3D joint angle data which reduced all joint angle waveforms into new uncorrelated PCs via an orthogonal transformation. Scatterplots of PC1 versus PC2 were used to visually inspect for clustering between the PC values for the 4 exercises. A one-way ANOVA was performed on the first 3 PC values for the 9 variables under analysis. Games-Howell post hoc tests identified variables that were significantly different between exercises. All exercises were clearly distinguishable using the PC scatterplot representing hip flexion-extension waveforms. ANOVA results revealed that PC1 for the knee flexion angle waveform was the only PC value statistically different across all exercises. Findings demonstrate clear potential to objectively distinguish between different knee rehabilitation exercises using IMU sensors and PCA. Flexion-extension angles at the hip and knee appear most suited for accurate separation, which will be further investigated on patient data and additional exercises


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 69 - 69
1 Nov 2018
Quinlan L
Full Access

Total knee arthroplasty (TKA) is becoming more prevalent as the average age of the general population increases and is generally considered to be a very effective and successful surgery. However, functional recovery post-surgery can often be less than optimal. Neuromuscular electrical stimulation (NMES) is a beneficial therapy proven to improve haemodynamics and muscle strength and may be of great benefit in improving functional recovery in the acute phase post-TKA. The objective of the study was to assess functional recovery in the period immediately following TKA and hospital discharge in response to a home-based NMES programme. Twenty-six TKA patients were randomized into a NMES stimulation or placebo-controlled group. All participants were given a research muscle stimulator to use at home post-discharge for 90 minutes per day over a period of 5 weeks. In the stimulation group, application of stimulation resulted in an electrically activated contraction of the soleus muscle. Patients in the placebo-controlled group received sensory stimulation only. Outcome measures were physical activity levels, joint range of motion and lower limb swelling, which were measured pre-surgery and on a weekly basis post-discharge up until the sixth post-surgical week. 90 minutes per day NMES stimulation significantly increased the Activity Time (P = 0.029 week 1 post-discharge) and the number of Stepping Bouts (P < 0.05 weeks 1 to 4 post-discharge) in the early post-discharge phase. While there was a trend towards a greater knee flexion with use of NMES, this did not reach statistical significance (P = 0.722). No effect of NMES was observed on swelling (P > 0.05 for all measures). Compliance to the NMES therapy was measured by an on-board SIM card in the NMES device, with a 95% and 94% time compliance rate for the stimulation and placebo-controlled groups respectively. The results of this study suggest that NMES may be very useful in improving functional recovery through increasing physical activity levels in the early post-TKA discharge phase. The results of this study warrant further investigation into the use of an optimized NMES protocol whereby improvements in knee range of motion and swelling may also be observed


Bone & Joint 360
Vol. 6, Issue 6 | Pages 41 - 43
1 Dec 2017
Foy MA