Advertisement for orthosearch.org.uk
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 13 - 13
7 Jun 2023
Diffley T Ferry J Sumarlie R Beshr M Chen B Clement N Farrow L
Full Access

Appropriate surgical management of hip fractures has major clinical and economic consequences. Recently IMN use has increased compared to SHS constructs, despite no clear evidence demonstrating superiority of outcome. We therefore set out to provide further evidence about the clinical and economic implications of implant choice when considering hip fracture fixation strategies. A retrospective cohort study using Scottish hip fracture audit (SHFA) data was performed for the period 2016–2022. Patients ≥50 with a hip fracture and treated with IMN or SHS constructs at Scottish Hospitals were included. Comparative analyses, including adjustment for confounders, were performed utilising Multivariable logistic regression for dichotomous outcomes and Mann-Whitney-U tests for non-parametric data. A sub-group analysis was also performed focusing on AO-A1/A2 configurations which utilised additional regional data. Cost differences in Length of Stay (LOS) were calculated using defined costs from the NHS Scotland Costs book. In all analyses p<0.05 denoted significance. 13638 records were included (72% female). 9867 received a SHS (72%). No significant differences were identified in 30 or 60-day survival (Odds Ratio [OR] 1.05, 95%CI 0.90–1.23; p=0.532), (OR 1.10, 95%CI 0.97–1.24; p=0.138) between SHS and IMN's. There was however a significantly lower early mobilisation rate with IMN vs SHS (OR 0.64, 95%CI 0.59–0.70; p<0.001), and lower likelihood of discharge to domicile by day-30 post-admission (OR 0.77, 95%CI 0.71–0.84; p<0.001). Acute and overall, LOS were significantly lower for SHS vs IMN (11 vs 12 days and 20 vs 24 days respectively; p<0.001). Findings were similar across a sub-group analysis of 559 AO A1/A2 fracture configurations. Differences in LOS potentially increases costs by £1230 per-patient, irrespective of the higher costs of IMN's v SHS. Appropriate SHS use is associated with early mobilisation, reduced LOS and likely with reduced cost of treatment. Further research exploring potential reasons for the identified differences in early mobilisation are warranted


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1136 - 1145
14 Sep 2020
Kayani B Onochie E Patil V Begum F Cuthbert R Ferguson D Bhamra JS Sharma A Bates P Haddad FS

Aims. During the COVID-19 pandemic, many patients continue to require urgent surgery for hip fractures. However, the impact of COVID-19 on perioperative outcomes in these high-risk patients remains unknown. The objectives of this study were to establish the effects of COVID-19 on perioperative morbidity and mortality, and determine any risk factors for increased mortality in patients with COVID-19 undergoing hip fracture surgery. Methods. This multicentre cohort study included 340 COVID-19-negative patients versus 82 COVID-19-positive patients undergoing surgical treatment for hip fractures across nine NHS hospitals in Greater London, UK. Patients in both treatment groups were comparable for age, sex, body mass index, fracture configuration, and type of surgery performed. Predefined perioperative outcomes were recorded within a 30-day postoperative period. Univariate and multivariate analysis were used to identify risk factors associated with increased risk of mortality. Results. COVID-19-positive patients had increased postoperative mortality rates (30.5% (25/82) vs 10.3% (35/340) respectively, p < 0.001) compared to COVID-19-negative patients. Risk factors for increased mortality in patients with COVID-19 undergoing surgery included positive smoking status (hazard ratio (HR) 15.4 (95% confidence interval (CI) 4.55 to 52.2; p < 0.001) and greater than three comorbidities (HR 13.5 (95% CI 2.82 to 66.0, p < 0.001). COVID-19-positive patients had increased risk of postoperative complications (89.0% (73/82) vs 35.0% (119/340) respectively; p < 0.001), more critical care unit admissions (61.0% (50/82) vs 18.2% (62/340) respectively; p < 0.001), and increased length of hospital stay (mean 13.8 days (SD 4.6) vs 6.7 days (SD 2.5) respectively; p < 0.001), compared to COVID-19-negative patients. Conclusion. Hip fracture surgery in COVID-19-positive patients was associated with increased length of hospital stay, more admissions to the critical care unit, higher risk of perioperative complications, and increased mortality rates compared to COVID-19-negative patients. Risk factors for increased mortality in patients with COVID-19 undergoing surgery included positive smoking status and multiple (greater than three) comorbidities. Cite this article: Bone Joint J 2020;102-B(9):1136–1145


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 48 - 48
1 Oct 2020
Kayani B Onochie E Patel V Begum F Cuthbert R Ferguson D Bhamra JS Sharma A Bates PD Haddad FS
Full Access

Background. There remains a paucity of clinical studies on the effects of coronavirus on perioperative outcomes, with no existing trials reporting on risk factors associated with increased risk of postoperative mortality in these patients. The objectives of this study were to assess perioperative complications and identify risk factors for increased mortality in patients with coronavirus undergoing surgery. Methods. This multicentre cohort study included 340 coronavirus negative patients versus 82 coronavirus positive patients undergoing surgical treatment for neck of femur fractures across nine NHS hospitals within Greater London, United Kingdom. Predefined study outcomes relating to patient demographics, fracture configuration, operative treatment, perioperative complications and mortality were recorded by observers using a standardised data collection proforma. Univariate and multivariate analysis were used to identify risk factors associated with increased risk of mortality. Findings. Coronavirus positive patients had increased risk of postoperative complications (89.0% vs 35.0%, p<0.001), higher rates of admission to high dependency and intensive care units (61.0% vs 18.2%, p<0.001), and increased length of hospital stay (13.8 ± 4.6 days vs 6.7 ± 2.5 days, p<0.001) compared to coronavirus negative patients. Postoperative complications in coronavirus positive patients included respiratory infections (13.4%), thromboembolic disease (13.4%), acute kidney injury (12.2%), and multi-organ dysfunction (12.2%). Coronavirus positive patients had increased risk of postoperative mortality (30.5% vs 10.3%, p<0.001) compared to coronavirus negative patients, with positive smoking status (Hazard ratio: 15.4 (95% CI: 4.55–52.2, p<0.001) and greater than three comorbidities (Hazard ratio: 13.5 (95% CI: 2.82–66.0, p<0.001) associated with increased risk of mortality. Interpretation. Surgery in coronavirus positive patients was associated with increased length of hospital stay, more admissions to the critical care unit, higher risk of perioperative complications and increased mortality compared to coronavirus negative patients. Multivariate analysis revealed that smoking and multiple pre-existing comorbidities were associated with increased risk of postoperative mortality


Bone & Joint Open
Vol. 3, Issue 3 | Pages 182 - 188
1 Mar 2022
Boktor J Badurudeen A Rijab Agha M Lewis PM Roberts G Hills R Johansen A White S

Aims

In UK there are around 76,000 hip fractures occur each year 10% to 15% of which are undisplaced intracapsular. There is considerable debate whether internal fixation is the most appropriate treatment for undisplaced fractures in older patients. This study describes cannulated hip screws survivorship analysis for patients aged ≥ 60 years with undisplaced intra-capsular fractures.

Methods

This was a retrospective cohort study of consecutive patients aged ≥ 60 years who had cannulated screws fixation for Garden I and II fractures in a teaching hospital between March 2013 and March 2016. The primary outcome was further same-side hip surgery. Descriptive statistics were used and Kaplan-Meier estimates calculated for implant survival.


Bone & Joint Open
Vol. 2, Issue 6 | Pages 443 - 456
28 Jun 2021
Thompson JW Corbett J Bye D Jones A Tissingh EK Nolan J

Aims

The Exeter V40 cemented polished tapered stem system has demonstrated excellent long-term outcomes. This paper presents a systematic review of the existing literature and reports on a large case series comparing implant fractures between the Exeter V40 series; 125 mm and conventional length stem systems.

Methods

A systematic literature search was performed adhering to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. In parallel, we performed a retrospective single centre study of Exeter V40 femoral stem prosthetic fractures between April 2003 and June 2020.


Bone & Joint Research
Vol. 8, Issue 7 | Pages 313 - 322
1 Jul 2019
Law GW Wong YR Yew AK Choh ACT Koh JSB Howe TS

Objectives

The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling.

Methods

A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles.