Advertisement for orthosearch.org.uk
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 117 - 117
11 Apr 2023
Roser M Izatt M Labrom R Askin G Little P
Full Access

Anterior vertebral body tethering (AVBT) is a growth modulating procedure used to manage idiopathic scoliosis by applying a flexible tether to the convex surface of the spine in skeletally immature patients. The purpose of this study is to determine the preliminary clinical outcomes for an adolescent patient cohort.

18 patients with scoliosis were selected using a narrow selection criteria to undergo AVBT. Of this cohort, 11 had reached a minimum follow up of 2 years, 4 had reached 18 months, and 3 had reached 6 months. These patients all demonstrated a primary thoracic deformity that was too severe for bracing, were skeletally immature, and were analysed in this preliminary study of coronal plane deformity correction.

Using open-source image analysis software (ImageJ, NIH) PA radiographs taken pre-operatively and at regular follow-up visits post-operatively were used to measure the coronal plane deformity of the major and compensatory curves.

Pre-operatively, the mean age was 12.0 years (S.D. 10.7 – 13.3), mean Sanders score 2.6 (S.D. 1.8-3.4), all Risser 0 and pre-menarchal, with mean main thoracic Cobb angle of 52° (S.D. 44.2-59.8°). Post-operatively the mean angle decreased to 26.4° (S.D. 18.4-32°) at 1 week, 30.4° (S.D. 21.3-39.6°) at 2 months, 25.7° (S.D. 18.7-32.8°) at 6 months, 27.9° (S.D. 16.2-39.6°) at 12 months, and 36.8° (S.D. 22.6– 51.0°) at 18 months and 38.2° (S.D. 27.6-48.7°) at 2 years. The change in curve at 2 years post-operative was statistically significant (P=0.004).

There were 4 tether breakages identified that did not require return to theatre as yet, one patient underwent a posterior spinal instrumented fusion due to curve progression.

AVBT is a promising new growth modulation technique for skeletally immature patients with progressive idiopathic scoliosis. This study has demonstrated a reduction in scoliosis severity.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 10 - 10
1 Mar 2021
To K Khan W Marway P
Full Access

Companies manufacturing total knee arthroplasty (TKA) prostheses produce a variety of tibial and femoral components of different dimensions denoted by numbers or letters. Surgeons frequently implant components that are compatible but not of the same size on the femur and tibia. Recent studies suggest that equally sized femoral and tibial components produce better outcomes compared to size-mismatched components. In our study, we aim to explore the relationship between component size and outcome measured by oxford knee score at six weeks and one year following TKA.

A cohort of twenty-four patients who underwent TKA and had well-functioning prosthesis were studied. Thirteen (54%) had equally sized TKA components implanted, seventy-four patients (42%) had components that were mismatched by one size, and one (4%) had components that were mismatched by more than one size. The Oxford Knee Score (OKS) obtained preoperatively, at six weeks and one year postoperatively were retrieved from an electronic database. All data were analysed using R software.

A significant improvement in pre-operative and one-year postoperative OKS was observed. Patients who received one-size mismatched tibial and femoral components demonstrated a less pronounced improvement in OKS as compared with patients who received equally sized components.

When possible, it may be best to utilise equally sized prosthetic tibial and femoral components when performing total knee arthroplasty. Manufacturers may be able to produce better patient outcomes by including prostheses that are between sizes as part of their production line.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 9 - 9
1 Apr 2018
Garcia-Rey E Carbonell R Cordero J Gomez-Barrena E
Full Access

Introduction

Durable bone fixation of uncemented porous-coated acetabular cups can be observed at a long-term, however, polyethylene (PE) wear and osteolysis may affect survivorship. Accurate wear measurements correlated with clinical data may offer unique research information of clinical interest about this highly debated issue.

Objetive

We assessed the clinical and radiological outcome of a single uncemented total hip replacement (THR) system after twenty years analysing polyethylene wear and the appearance of osteolysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 56 - 56
1 Jan 2017
García-Rey E Gómez-Barrena E García-Cimbrelo E
Full Access

Total hip replacement (THR) in young patients has been associated to higher revision rates than in older population. Different conditions may lead to end-stage arthritis of the hip in these patients. We compared the clinical and radiological outcome of two different groups of young and very young patients who underwent a ceramic-on-ceramic THR.

120 hips were prospectively followed for a mean of 10.4 years (range, 5 to 17). 38 patients (46 hips) were less than 30 years old (group 1), and, 68 (74 hips) were between 31 and 40 years old (group 2). Weight (p<0.001) and physical activity level were greater in group 2 (p<0.001). Preoperative function (p=0.03) and range of mobility (p=0.03) were worse in group 1. Primary osteoarthritis was not found in any case. Rheumatoid juvenile arthritis was the most frequent diagnosis in group 1 and avascular necrosis of the femoral head in group 2. A femoral funnel-shaped type 1 according to Dorr was more frequent in group 2 (p=0.04). The same ceramic-on-ceramic uncemented THR was used in all cases. Screws for cup fixation were only used when strictly needed. We analysed the clinical results according to the Merle-D´Aubignè and Postel scale, the postoperative radiological reconstruction of the hip and the radiological appearance of cup loosening. Kaplan-Meier survivorship analysis was used to estimate the cumulative probability of not having a revision surgery.

Screw use required to obtain a secured interference fit of the acetabular component was found more frequently in group 1 (p=0.01). Postoperative pain (p=0.002) and function (p=0.002) were better in group 1. Mean acetabular abduction angle of the cup was greater in group 1 (p=0.03) and reconstruction to the hip rotation center according to Ranawat (p=0.01) was better in group 2. Placement of the acetabular component inside the Lewinnek´s zone and stem position were similar in both groups. No hips were revised due to complications related to ceramic or to stem loosening. Three cups were revised for aseptic loosening in group 1 and four in group 2. The survival rate for cup aseptic loosening at 15 years was 92.3% (95% CI: 83.7 to 100) for group 1 and 93.1% (95% CI: 85.3 to 99.9) for group 2 (Log rank, p=0.88).

Ceramic-on-ceramic uncemented THR is an excellent option for young and very young patients. Despite worse preoperative conditions in patients under the age of 30 years, a similar clinical outcome was found in this series.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2017
Stefanou M Pasparakis D Darras N Papagelopoulos P
Full Access

Many studies describe the use of the Ilizarov ring fixator for lower limb lengthening and for the management of the 3-dimensional lower limb deformities in achondroplasia, and most confirm the efficacy of this technique. However, long term follow up of these achondroplastic patients is lacking. Most studies have focused on magnitude of lengthening, treatment time required and complications, but no study has analyzed the long term postoperative condition of these patients using an objective, functional method such as gait analysis.

Nineteen (19) achondroplastic patients, 12 males and 7 females, aged 19–38 years (mean 27.3 y) who have undergone tibia and femur lengthening, using the Ilizarov method, at the age of 9–19 years (mean 12.6 y), were evaluated 5–19 years (mean 10.1 y) after their last surgery, using 3-dimensional gait analysis. Nineteen (19) normal, height-matched subjects were used as controls. The VICON Nexus 8 Camera System was used to accurately measure spatiotemporal characteristics (walking velocity, stride length, step length, cadence) and kinematics (range of motion) of lower limb joints. Statistical comparison of deformity parameters between achondroplastic patients and normal population was done using the student t- test. A level of p<0.05 was considered statistically significant.

Walking velocity, step length and stride length were statistically significantly decreased (p<0.05) in achondroplastic patients compared to normal population values. The achondroplastic group presented with excessive anterior pelvic tilt (mean 21.9o± 7.3), excessive pelvic rotation (range 28.7o±7.8), decreased hip extension (mean 1.8o±10.1) and decreased plantar flexion (mean 17.1o±5.1) when compared to normal controls. There was no statistically significant difference in the knee kinematics between the operated achondroplastic patients and normal controls.

The achondroplastic patients present decreased values in their spatiotemporal characteristics compared to the normal subjects because, despite the height gain, their lower limbs remain shorter. Their excessive anterior pelvic tilt is attributed to their lordosis. Their excessive forward pelvic rotation is an attempt to increase stride and step length. The decreased hip extension is due to their anterior pelvic tilt. The correction of these patients genu varum restored knee kinematics to normal. In order to address the hip and pelvis deformities a proximal femoral osteotomy should be considered.

The Ilizarov method provides functional height gain and substantially corrects the three-dimensional lower limb deformities of achondroplastic patients especially around the knee joint but more planning needs to be implemented when the system is applied to correct the disease specific deformities of the hip and pelvis. Gait analysis is an objective tool that can be used to address these design issues.


Introduction

The purpose of this study was to evaluate the functional and radiographical results in patients younger than 30 years who underwent cementless third generation ceramic-on-ceramic total hip arthroplasty for osteonecrosis of the femoral head.

Methods

Forty one patients (55 hips) who underwent total hip arthroplasty with third generation ceramic-on-ceramic bearings for osteonecrosis of the femoral head with a minimum 4-year follow-up were included in this study. There were 26 men and 15 women who had a mean age of 26 years (range, 16 to 29 years). The average duration of follow-up was 6 years (range, 4 to 7 years). All surgeries were done by a single hip surgeon and third generation ceramic-on-ceramic articulations were used. Securefit (Stryker) acetabular components were used in 46 hips and Duraloc (Depuy) in 9 hips. Accolade (Stryker) femoral stems were used in 33 hips, cone prosthesis (Zimmer) in 18 hips and CLS (Zimmer) in 4 hips. Functional results were measured by Harris hip (HHS) and WOMAC scores. Radiographic evaluation was assessed for loosening and osteolysis according to Gruen and Delee and Charnley criteria.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 203 - 203
1 Jul 2014
Rowell S Muratoglu O
Full Access

Summary

Fifteen irradiated, vitamin E-diffused UHMWPE retrievals with up to three years in vivo service showed no appreciable oxidation, nor change in material properties from a never-implanted liner, and showed a 94% decrease in free radical content.

Introduction

Radiation cross-linking, used to improve wear resistance of ultra-high molecular weight polyethylene (UHMWPE) bearings used in total joint arthroplasty, generates residual free radicals which are the precursors to oxidative embrittlement. First generation materials adopted thermal treatments to eliminate or reduce free radical content, but came with compromises in reduced mechanical properties or insufficient stabilization. A second generation alternative method infuses an antioxidant, vitamin E, into irradiated UHMWPE to stabilise free radicals while maintaining fatigue strength. In vitro studies predict excellent oxidation and wear resistance in vitamin E-stabilised bearings, but the long-term in vivo oxidation behavior, influenced by lipid absorption and cyclic loading, remains largely unknown. Our aim was to investigate in vivo changes in UHMWPE surgically-retrieved explants that were radiation cross-linked and stabilised by vitamin E.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 130 - 130
11 Apr 2023
Biddle M Wilson V Miller N Phillips S
Full Access

Our aim was to ascertain if K-wire configuration had any influence on the infection and complication rate for base of 4th and 5th metacarpal fractures. We hypothesised that in individuals whose wires crossed the 4th and 5th carpometacarpal joint (CMCJ), the rate of complications and infection would be higher. Data was retrospectively analysed from a single centre. 106 consecutive patients with a base of 5th (with or without an associated 4th metacarpal fracture) were analysed between October 2016 and May 2021. Patients were split into two groups for comparison; those who did not have K-wires crossing the CMCJ's and those in whose fixation had wires crossing the joints. Confounding factors were accounted for and Statistical analysis was performed using SPSS version 20 software. Of 106 patients, 60 (56.6%) patients did have K-wires crossing the CMCJ. Wire size ranged from 1.2-2.0 with 65 individuals (65.7%) having size 1.6 wires inserted. The majority of patients, 66 (62.9%) underwent fixation with two wires (range 1-4). The majority of infected cases (88.9%) were in patients who had k-wires crossing the CMCJ, this trended towards clinical significance (p=0.09). Infection was associated with delay to theatre (p=0.002) and longer operative time (p=0.002). In patients with a base of 4th and 5th metacarpal fractures, we have demonstrated an increased risk of post-operative infection with a K-wire configuration that crosses the CMCJ. Biomechanical studies would be of use in determining the exact amount of movement across the CMCJ, with the different K-wire configuration in common use, and this will be part of a follow-up study


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 28 - 28
11 Apr 2023
Wither C Lawton J Clarke D Holmes E Gale L
Full Access

Range of Motion (ROM) assessments are routinely used during joint replacement to evaluate joint stability before, during and after surgery to ensure the effective restoration of patient biomechanics. This study aimed to quantify axial torque in the femur during ROM assessment in total hip arthroplasty to define performance criteria against which hip instruments can be verified. Longer term, this information may provide the ability to quantitatively assess joint stability, extending to quantitation of bone preparation and quality. Joint loads measured with strain-gaged instruments in five cadaveric femurs prepared using posterior approach were analysed. Variables such as surgeon-evaluator, trial offset and specimen leg and weight were used to define 13 individual setups and paired with surgeon appraisal of joint tension for each setup. Peak torque loads were then identified for specific motions within the ROM assessment. The largest torque measured in most setups was observed during maximum extension and external rotation of the joint, with a peak torque of 13Nm recorded in a specimen weighing 98kg. The largest torque range (19.4Nm) was also recorded in this specimen. Other motions within the trial reduction showed clear peaks in applied torque but with lower magnitude. Relationships between peak torque, torque range and specimen weight produced an R2 value greater than 0.65. The data indicated that key influencers of torsional loads during ROM were patient weight, joint tension and limb motion. This correlation with patient weight should be further investigated and highlights the need for population representation during cadaveric evaluation. Although this study considered a small sample size, consistent patterns were seen across several users and specimens. Follow-up studies should aim to increase the number of surgeon-evaluators and further vary specimen size and weight. Consideration should also be given to alternative surgical approaches such as the Direct Anterior Approach


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 146 - 146
1 Nov 2021
Antoniou J
Full Access

Osteoarthritis (OA) is a painful and disabling chronic condition that constitutes a major challenge to health care worldwide. There is currently no cure for OA and the analgesic pharmaceuticals available do not offer adequate and sustained pain relief, often being associated with significant undesirable side effects. Another disease associated with degenerating joints is Intervertebral disc degeneration (IVDD) which is a leading cause of chronic back pain and loss of function. It is characterized by the loss of extracellular matrix, specifically proteoglycan and collagen, tissue dehydration, fissure development and loss of disc height, inflammation, endplate sclerosis, cell death and hyperinnervation of nociceptive nerve fibers. The adult human IVD seems incapable of intrinsic repair and there are currently no proven treatments to prevent, stop or even retard disc degeneration. Fusion is currently the most common surgical treatment of symptomatic disc disease. However, radiographic follow-up studies have revealed that many patients develop adjacent segment disc degeneration due to altered spine biomechanics. The development of safe and efficacious disease modifying OA drugs (DMOADs) that treat pain and inflammation in joints will improve our ability to control the disease. I addition, a biologic treatment of IVDD is desirable. This presentation will provide an overview of recent advances and future prospects of a multimodal biologic treatment of OA, and IVDD. We will focus on Link N, a naturally occurring peptide representing the N terminal region of link protein and the first 1–8 residues of Link N (short Link N, sLN) responsible for the biologic therapy in question


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 118 - 118
1 Mar 2021
Jeuken R Roth A Peters M Welting T Rhijn L Thies J Emans P
Full Access

Focal knee resurfacing implants (FKRIs) are typically intended to treat focal cartilage defects in middle-aged patients. All currently available FKRIs are (partly) composed of metal, which potentially leads to degeneration of the opposing articulating cartilage and hampers follow-up using magnetic resonance imaging (MRI). The purpose of this study was to investigate the in vivo osseointegration process of a novel non-degradable thermoplastic polycarbonate-urethane (TPU) osteochondral implant. Bi-layered implants measuring 6 mm in diameter, with a double-curvature to match the approximate curvature of the goat medial femoral condyle were fabricated. TPU implants were composed of an articulating Bionate® II 80A top layer, and a Bionate® 75D bottom layer (DSM Biomedical, Geleen, the Netherlands) which is intended to osseointegrate. A biphasic calcium phosphate coating formulation, optimized during a prior in vitro study, was applied to half of the TPU implants, while the other half was left uncoated. Bi-layered metal implants (articulating cobalt-chromium top layer and titanium bottom layer) were used as positive control implants. Eight implants per group were implanted bilaterally in the medial femoral condyle of the stifle joints in 12 Dutch milk goats. 18F-sodium fluoride (18F-NaF) positron emission tomography-computed tomography (PET-CT) scanning was performed at 3 and 12 weeks postoperatively, and the corrected maximum standard uptake values (cSUVmax) was calculated to assess the peri-implant bone metabolism. After sacrifice 12 weeks postoperatively, bone histomorphometric analysis was performed to assess the bone-to-implant contact area (BIC). Student's T-test was used in case of normal distribution and the Mann-Whitney-U-test was used in case of abnormal distribution for comparison of BIC and cSUVmax. The BIC value of 10.27 ± 4.50% (mean ± SD) for the BCP-coated TPU implants was significantly (P=0.03) higher than the 4.50 ± 2.61% for the uncoated TPU implants. The uncoated TPU implants scored significantly (P=0.04) lower than the BIC of 12.81 ± 7.55% for the metal implants, whereas there was no significant difference between BCP-coated TPU implants and the metal implants (P=0.68). There was a strong correlation between the cSUVmax values and the BIC values at 12 weeks (Pearson's R=0.74, P=0.001). The cSUVmax values significantly decreased between 3 and 12 weeks for the metal implants (p=0.04). BCP-coated TPU implants followed a similar trend but did not reach statistical significance (p=0.07). cSUVmax in the uncoated TPU implants did not show a significant difference between the time-points (p=0.31). Osseointegration of BCP-coated TPU implants did not significantly differ from metal implants. 18F-NaF PET-CT is a feasible modality to assess osseointegration patterns and showed a similar trend between the BCP-coated and metal implants. Hence, an implant fully composed of TPU may avoid the typical metal-related drawbacks of currently available FKRIs. Long-term follow-up studies are advocated to address the effects of the implant to the opposing cartilage, and are therefore warranted


Bone & Joint Research
Vol. 9, Issue 3 | Pages 146 - 151
1 Mar 2020
Waldstein W Koller U Springer B Kolbitsch P Brodner W Windhager R Lass R

Aims

Second-generation metal-on-metal (MoM) articulations in total hip arthroplasty (THA) were introduced in order to reduce wear-related complications. The current study reports on the serum cobalt levels and the clinical outcome at a minimum of 20 years following THA with a MoM (Metasul) or a ceramic-on-polyethylene (CoP) bearing.

Methods

The present study provides an update of a previously published prospective randomized controlled study, evaluating the serum cobalt levels of a consecutive cohort of 100 patients following THA with a MoM or a CoP articulation. A total of 31 patients were available for clinical and radiological follow-up examination. After exclusion of 11 patients because of other cobalt-containing implants, 20 patients (MoM (n = 11); CoP (n = 9)) with a mean age of 69 years (42 to 97) were analyzed. Serum cobalt levels were compared to serum cobalt levels five years out of surgery.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 180 - 180
1 Jul 2014
Sultan J Chapman G Jones R
Full Access

Summary. This study shows a significant reduction in knee adduction moment in patients with medial compartment osteoarthritis, in both the symptomatic and asymptomatic knees. Long-term follow-up studies are required to confirm the effect of treating the asymptomatic side on disease progression. Background. The knee is the commonest joint to be affected by osteoarthritis, with the medial compartment commonly affected. Knee osteoarthritis is commonly bilateral, yet symptoms may initially present unilaterally. Higher knee adduction moment has been associated with the development and progression of medial compartment knee osteoarthritis. The aim of this study was to assess the effect of lateral wedge insoles on the asymptomatic knee of patients with unilateral symptoms of medial compartment knee osteoarthritis. Methods. Twenty patients were assessed using a 3D optoelectronic tracking system, with 16 infrared camera, passive markers and four force platforms. Three different insoles were tested; a standard control shoe, the Boston lateral wedge insole (inclined at 5° throughout the full length of the insole) and the Salford insole (inclined at 5° throughout the full length of the insole, with medial arch support). A minimum of 5 trials per each insole were used. Kinetic and kinematic data were collected and processed using Qualysis Track Manager ® and Visual 3D™. Results. There was a significant reduction in knee adduction moment for both the Salford and Boston insoles as compared to the control shoe. This was 9.5–14.2% for the asymptomatic side, and 5.8–10.7% for the symptomatic side for the Salford and Boston insoles respectively. Although the reduction was larger on the asymptomatic side, this was not statistically significant. Patients reported significant reduction in pain with both Salford and Boston insoles as compared to the control shoe, and found the Salford insole to be the most comfortable. Stride length and walking speed was significantly higher with the Salford insole. Conclusions. This study confirms the effect of lateral wedge insoles on reducing knee adduction moment in patients with medial compartment osteoarthritis, in both the symptomatic and asymptomatic knees. Long-term follow-up studies are required to confirm the effect of treating the asymptomatic side on disease progression


Bone & Joint Research
Vol. 5, Issue 9 | Pages 403 - 411
1 Sep 2016
Mrosek EH Chung H Fitzsimmons JS O’Driscoll SW Reinholz GG Schagemann JC

Objectives. We sought to determine if a durable bilayer implant composed of trabecular metal with autologous periosteum on top would be suitable to reconstitute large osteochondral defects. This design would allow for secure implant fixation, subsequent integration and remodeling. Materials and Methods. Adult sheep were randomly assigned to one of three groups (n = 8/group): 1. trabecular metal/periosteal graft (TMPG), 2. trabecular metal (TM), 3. empty defect (ED). Cartilage and bone healing were assessed macroscopically, biochemically (type II collagen, sulfated glycosaminoglycan (sGAG) and double-stranded DNA (dsDNA) content) and histologically. Results. At 16 weeks post-operatively, histological scores amongst treatment groups were not statistically different (TMPG: overall 12.7, cartilage 8.6, bone 4.1; TM: overall 14.2, cartilage 9.5, bone 4.9; ED: overall 13.6, cartilage 9.1, bone 4.5). Metal scaffolds were incorporated into the surrounding bone, both in TM and TMPG. The sGAG yield was lower in the neo-cartilage regions compared with the articular cartilage (AC) controls (TMPG 20.8/AC 39.5, TM 25.6/AC 33.3, ED 32.2/AC 40.2 µg sGAG/1 mg respectively), with statistical significance being achieved for the TMPG group (p < 0.05). Hypercellularity of the neo-cartilage was found in TM and ED, as the dsDNA content was significantly higher (p < 0.05) compared with contralateral AC controls (TM 126.7/AC 71.1, ED 99.3/AC 62.8 ng dsDNA/1 mg). The highest type II collagen content was found in neo-cartilage after TM compared with TMPG and ED (TM 60%/TMPG 40%/ED 39%). Inter-treatment differences were not significant. Conclusions. TM is a highly suitable material for the reconstitution of osseous defects. TM enables excellent bony ingrowth and fast integration. However, combined with autologous periosteum, such a biocomposite failed to promote satisfactory neo-cartilage formation. Cite this article: E. H. Mrosek, H-W. Chung, J. S. Fitzsimmons, S. W. O’Driscoll, G. G. Reinholz, J. C. Schagemann. Porous tantalum biocomposites for osteochondral defect repair: A follow-up study in a sheep model. Bone Joint J 2016;5:403–411. DOI: 10.1302/2046-3758.59.BJR-2016-0070.R1


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 69 - 69
1 Jan 2017
Van Der Straeten C Banica T De Smet A Van Onsem S Sys G
Full Access

Systemic metal ion monitoring (Co;Cr) has proven to be a useful screening tool for implant performance to detect failure at an early stage in metal-on-metal hip arthroplasty. Several clinical studies have reported elevated metal ion levels after total knee arthroplasty (TKA), with fairly high levels associated with rotating hinge knees (RHK) and megaprostheses. 1. In a knee simulator study, Kretzer. 2. , demonstrated volumetric wear and corrosion of metallic surfaces. However, prospective in vivo data are scarce, resulting in a lack of knowledge of how levels evolve over time. The goal of this study was to measure serum Co and Cr levels in several types TKA patients prospectively, evaluate the evolution in time and investigate whether elevated levels could be used as an indicator for implant failure. The study was conducted at Ghent University hospital. 130 patients undergoing knee arthroplasty were included in the study, 35 patients were lost due to logistic problems. 95 patients with 124 knee prostheses had received either a TKA (primary or revision) (69 in 55 patients), a unicompartimental knee arthroplasty (7 UKA), a RHK (revision −7 in 6 patients) or a megaprosthesis (malignant bone tumours − 28 in 27 patients). The TKA, UKA and RHK groups were followed prospectively, with serum Co and Cr ions measured preoperatively, at 3,6 and 12 months postoperatively. In patients with a megaprosthesis, metal ions were measured at follow-up (cross-sectional study design). In primary knees, we did not observe an increase in serum metal ion levels at 3, 6 or 12 months. Two patients with a hip arthroplasty had elevated preTKA Co and Cr levels. There was no difference between unilateral and bilateral knee prostheses. In the revision group, elevated pre-revision levels were found in 2 failures for implant loosening. In both cases, ion levels decreased postoperatively. In revisions with a standard TKA, there was no significant increase in metal ions compared to primary knee arthroplasty. RHK were associated with a significant increase in Co levels even at short-term (3–12 months). The megaprosthesis group had the highest metal ion levels and showed a significant increase in Co and Cr with time in patients followed prospectively. With the current data, we could not demonstrate a correlation between metal ion levels, size of the implant or length of time in situ. In primary knee arthroplasty with a standard TKA or UKA, metal ion levels were not elevated till one year postoperatively. This suggests a different mechanism of metal ion release in comparison to metal-on-metal hip arthroplasties. In two cases of revision for implant loosening, pre-revision levels were elevated, possibly associated with component wear, and decreased after revision. With RHK, slightly elevated ion levels were found prospectively. Megaprostheses had significantly elevated Co and Cr levels, due to corrosion of large metallic surfaces and/or wear of components which were not perfectly aligned during difficult reconstruction after tumour resection. Further research is needed to assess the clinical relevance of metal ion levels in knee arthroplasty


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 12 | Pages 1703 - 1709
1 Dec 2010
Aoki H Nagao Y Ishii S Masuda T Beppu M

In order to evaluate the relationship between acetabular and proximal femoral alignment in the initiation and evolution of osteoarthritis of the dysplastic hip, the acetabular and femoral angles were calculated geometrically from radiographs of 62 patients with pre-arthrosis and early osteoarthritis. The sum of the lateral opening angle of the acetabulum and the neck-shaft angle was defined as the lateral instability index (LII), and the sum of the anterior opening angle of the acetabulum and the anteversion angle of the femoral neck as the anterior instability index (AII). These two indices were compared in dysplastic and unaffected hips. A total of 22 unilateral hips with pre-arthrosis were followed for at least 15 years to determine whether the two indices were associated with the progression of osteoarthritis. The LII of the affected hips (197.4 (. sd. 6.0)) was significantly greater than that of the unaffected hips (1830 (. sd. 6.9)). A follow-up study of 22 hips with pre-arthrosis showed that only the LII was associated with progression of the disease, and an LII of 196 was the threshold value for this progression


Bone & Joint Research
Vol. 7, Issue 3 | Pages 244 - 251
1 Mar 2018
Tawonsawatruk T Sriwatananukulkit O Himakhun W Hemstapat W

Objectives

In this study, we compared the pain behaviour and osteoarthritis (OA) progression between anterior cruciate ligament transection (ACLT) and osteochondral injury in surgically-induced OA rat models.

Methods

OA was induced in the knee joints of male Wistar rats using transection of the ACL or induction of osteochondral injury. Changes in the percentage of high limb weight distribution (%HLWD) on the operated hind limb were used to determine the pain behaviour in these models. The development of OA was assessed and compared using a histological evaluation based on the Osteoarthritis Research Society International (OARSI) cartilage OA histopathology score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_4 | Pages 20 - 20
1 Jan 2013
Heywood C Birch N
Full Access

Statement of Purposes. Functional Restoration (FR) and spinal fusion are both used as treatment for patients with chronic low back pain however opinions are divided over their long term efficacy. This study examines the 18 month to 8 year outcomes of stand-alone lumbar fusion (STALIF) at L5/S1 and FR in similar groups of patients. Methods. A prospective audit was undertaken using data routinely collected from the practice of the senior author. Pain (VAS), disability (ODI) and patients' subjective appraisals were used as comparable outcome measures. SPSS was used for statistical analysis. Results. STALIF patients had sustained significant improvements in their VAS and ODI scores at study end, compared to the pre-operative assessments. FR patients demonstrated significant improvements in their VAS scores and measurable functionality on discharge from the programme, but these deteriorated by the one-month follow-up. At study end there was a significant deterioration in the outcomes compared to discharge. Patient perceived success was 85% in the STALIF patients and 58% in the FR. 24% of FR patients subsequently required surgery. Conclusions. Both groups demonstrated statistically significant improvements in pain and disability/functionality scores during the period of the study however improvements in the FR groups occurred only during the active phase and significantly reduced by study end. The low patient satisfaction rating for the FR group and the need for 25% to subsequently undergo surgery indicates that further robust investigation to clarify “real” sustainability and rule out short-term benefits that arise from psychological cushioning or simply a training effect is required. Conflicts of Interest. None. Source of Funding. None. This abstract has not been previously published in whole or substantial part nor has it been presented at a national meeting


Bone & Joint Research
Vol. 6, Issue 2 | Pages 82 - 89
1 Feb 2017
Nagra NS Zargar N Smith RDJ Carr AJ

Objectives

All-suture anchors are increasingly used in rotator cuff repair procedures. Potential benefits include decreased bone damage. However, there is limited published evidence for the relative strength of fixation for all-suture anchors compared with traditional anchors.

Materials and Methods

A total of four commercially available all-suture anchors, the ‘Y-Knot’ (ConMed), Q-FIX (Smith & Nephew), ICONIX (Stryker) and JuggerKnot (Zimmer Biomet) and a traditional anchor control TWINFIX Ultra PK Suture Anchor (Smith & Nephew) were tested in cadaveric human humeral head rotator cuff repair models (n = 24). This construct underwent cyclic loading applied by a mechanical testing rig (Zwick/Roell). Ultimate load to failure, gap formation at 50, 100, 150 and 200 cycles, and failure mechanism were recorded. Significance was set at p < 0.05.


Bone & Joint Research
Vol. 3, Issue 1 | Pages 7 - 13
1 Jan 2014
Keurentjes JC Van Tol FR Fiocco M So-Osman C Onstenk R Koopman-Van Gemert AWMM Pöll RG Nelissen RGHH

Objectives

To define Patient Acceptable Symptom State (PASS) thresholds for the Oxford hip score (OHS) and Oxford knee score (OKS) at mid-term follow-up.

Methods

In a prospective multicentre cohort study, OHS and OKS were collected at a mean follow-up of three years (1.5 to 6.0), combined with a numeric rating scale (NRS) for satisfaction and an external validation question assessing the patient’s willingness to undergo surgery again. A total of 550 patients underwent total hip replacement (THR) and 367 underwent total knee replacement (TKR).