Optimal
Purpose: This cadaveric study examines how changes in femoral
Introduction: Restoring normal mechanical axis is one of the key goals of the total knee arthroplasty (TKA). The majority of the surgeons resect the tibia perpendicular to its axis in the coronal plane, then use an intra-medullary jig inserted through the centre of the knee or slightly medial to centre of the knee to resect the distal femur at a 6 or 7degree valgus angle. The aim was to establish the safety of using a predetermined valgus angle (VA) and
Introduction: Appropriate femoral component alignment is important for long-term survival of total knee arthroplasty (TKA). Valgus angle of femoral component is recommended as the angle between mechanical axis and anatomical axis of the femur. Intramedullary guide system is widely used for determining the valgus positioning of femoral component.
Aim: To evaluate time of union and functional recovery of the shoulder joint in humeral shaft fractures treated with antegrade intramedullary nailing. Methods: During 1998–2002, 29 patients (16 male and 13 female, mean age 43.7 years) with humeral shaft fractures underwent antegrade, proximal locked, intramedullary nailing. A modified extra-articular
Purpose. Femoral shaft fractures are routinely treated using antegrade intramedullary nailing under fluoroscopic guidance. Malreduction is common and can be due to multiple factors. Correct
Antegrade nailing of proximal humeral fractures
using a straight nail can damage the bony insertion of the supraspinatus
tendon and may lead to varus failure of the construct. In order
to establish the ideal anatomical landmarks for insertion of the
nail and their clinical relevance we analysed CT scans of bilateral
proximal humeri in 200 patients (mean age 45.1 years (. sd. 19.6;
18 to 97) without humeral fractures. The
To quantify bone-nail fit in response to varying nail placements by
The objective of this study was to analyze the biomechanical effect of an implanted ACL graft by determining the tunnel position according to the aspect ratio (ASR) of the distal femur during flexion-extension motion. To analyze biomechanical characteristics according to the ASR of the knee joint, only male samples were selected to exclude the effects of gender and 89 samples were selected for measurement. The mean age was 50.73 years, and the mean height was 165.22 cm. We analyzed tunnel length, graft bending angle, and stress of the graft according to tunnel entry position and aspect ratio (ratio of antero-posterior depth to medio-lateral width) of the articular surface for the distal femur during single-bundle outside-in anterior cruciate ligament reconstruction surgery. We performed multi-flexible-body dynamic analyses with wherein four ASR (98, 105, 111, and 117%) knee models. The various ASRs were associated with approximately 1-mm changes in tunnel length. The graft bending angle increased when the
Aims. Patient-specific glenoid guides (PSGs) claim an improvement in
accuracy and reproducibility of the positioning of components in
total shoulder arthroplasty (TSA). The results have not yet been
confirmed in a prospective clinical trial. Our aim was to assess
whether the use of PSGs in patients with osteoarthritis of the shoulder
would allow accurate and reliable implantation of the glenoid component. Patients and Methods. A total of 17 patients (three men and 14 women) with a mean age
of 71 years (53 to 81) awaiting TSA were enrolled in the study.
Pre- and post-operative version and inclination of the glenoid were
measured on CT scans, using 3D planning automatic software. During
surgery, a congruent 3D-printed PSG was applied onto the glenoid
surface, thus determining the
Introduction: Correct alignment in both coronal and sagittal planes has been shown to be associated with longevity of total knee arthroplasty. The majority of procedures are performed using an intramedullary rod with a femoral cutting jig, with a 5°–7° offset depending upon the anatomical and mechanical axes. The cutting jig rotates around the rod and therefore the rotational alignment of the jig will also affect the cut and final component position (in addition to the rod entry point). It is interesting that rotational alignment of the femoral component is often assessed after the distal resection has been made. The distal resection plane determines the final position of the femoral component, influences patellar tracking and medial/lateral, flexion/extension balancing. This study measures the resultant effect on the distal femoral resection when
Aim: End result study of closed intramedullary nailing of humerus fractures. Materials &
methods: Between 1995–2003, 42 patients with fracture of the humeral shaft, were selected to be treated by I.N. The average age was 48 years old (17years–82years) The Selection criteria were: α) loss of closed reduction (24 patients), b) pathological fractures (5 patients), c) non-union following external fixation (2 patients) and d) delay of union (7 patients). The intramedullary nail was inserted through a proximal
The aim of this study was to evaluate whether using a predetermined
Introduction. Bernese periacetabular osteotomy (PAO) repositions the acetabulum to increase femoral head coverage (FHC) in hip dysplasia. Currently, there is a paucity of objective peri-operative metrics to plan for optimal acetabular fragment repositioning. The MSk Lab Hip 3D Planner (MSkL-HP) measures acetabular morphology and simulates PAO cuts to achieve optimal FHC. We evaluated how adjusting location and orientation of cutting planes can alter FHC. Method. MSkL-HP simulated 274 feasible PAOs on four dysplastic hips. Femoroacetabular anatomy was landmarked to simulate cutting planes. Posterior column and ischial cuts were standardised, whilst iliac and pubic cut combinations varied. The slope of the iliac cut was either neutral (aligned to pelvis), exit point 5mm above the
Introduction and Aims: C1 lateral mass screw fixation offers a powerful alternative biomechanical fixaion for upper cervical disorders. The anatomical constraints to this fixation have not been described yet and are essential to ensure avoidance of neurovascular damage. Method: Fifty patients (including five patients with rheumatoid arthritis) underwent upper cervical CT scans. Analysis of these CT scans involved use of calibrated scan measurements to identify the midpoint of the posterior lateral mass, the dimensions of the lateral mass, the direction of optimum screw passage, the position of the vertebral foramen at C1 and the ideal
To introduce a new robot-assisted surgical system for spinal posterior fixation which called TiRobot, based on intraoperative three-dimensional images. TiRobot has three components: the planning and navigation system, optical tracking system and robotic arm system. By combining navigation and robot techniques, TiRobot can guide the screw trajectories for orthopedic surgeries. In this randomised controlled study approved by the Ethics Committee, 40 patients were involved and all has been fully informed and sign the informed consent. 17 patients were treated by free-hand fluoroscopy-guided surgery, and 23 patients were treated by robot-assisted spinal surgery. A total of 190 pedicle screws were implanted. The overall operation times were not different for both groups. None of the screws necessitated re-surgery for revised placement. In the robot-assisted group, assessment of pedicle screw accuracy showed that 102 of 102 screws (100%) were safely placed (<2 mm, category A+B). And mean deviation in
Aims: The accuracy of percutaneous CT-Fluoro navigation is compared with the accuracy of the surface-matching procedure. Methods: 68 transpedicular and transvertebral canals were placed percutaneously in an in vitro. The deviation between probe-position and pre-planed trajectory was measured. Evaluated were the mean deviation of the
Introduction. The use of the dynamic hip screw is common practice for the fixation of intertrochanteric fractures of the femur. The success of this procedure requires accurate guide wire placement. This can prove difficult at times and can result in repeated attempts leading to longer operating time, multiple tracks and more importantly greater radiation exposure to both patient and operating staff. We hypothesised that rather than using the standard anterior-posterior projected image (Figure 1) of a proximal femur, rotating the intensifier image (Figure 2) so that the guide wire appears to pass vertically makes it easier to visualise the projected direction of the guide wire. Methods. Fifty Specialist Registrars, thirty participating in the London hip meeting 2009, ten from Oxford and ten from Northern deanery orthopaedic rotations were involved in the study. They were presented with standard AP and rotated images of the femoral neck on paper using 135 degree template to replicate the DHS guide. The participants were asked to mark the
Introduction: C1 lateral mass screw fixation offers a powerful alternative biomechanical fixation for upper cervical disorders. The anatomical constraints to this fixation have not been described yet and are essential to ensure avoidance of neurovascular damage. Methods: 50 patients (including 5 patients with rheumatoid arthritis) underwent upper cervical CT scans. Analysis of these CT scans involved use of calibrated scan measurements to identify the midpoint of the posterior lateral mass, the dimensions of the lateral mass, the direction of optimum screw passage, the position of the vertebral foramen at C1 and the ideal