Retained polymethylmethacrylate (PMMA) debris in surgical instrument trays is a rare, but disquieting situation for the arthroplasty surgeon. Although retained debris could be considered to be sterile after autoclaving, there is no peer-reviewed literature to support this assumption. This uncertainty and subsequent fear of contamination from this bioburden often leads to operating room personnel turning over entire surgical tables and opening new surgical instruments, which consumes time and burdens a hospital's sterilization infrastructure. Consequently, the purpose of the current study was to determine if retained, heavily contaminated PMMA in surgical trays could be effectively sterilized through clinically utilized autoclave protocols. MSSA (Xen36, Perkin Elmer) biofilm was grown on identically sized PMMA (Palacos R) coupons for 72-hour duration. Following incubation, coupons were exposed to three commonly used sterilization protocols. Cobalt-Chrome (CC) coupons were included in the same tray, replicating instruments in proximity to retained PMMA. Autoclave protocols included: 1.) Single Instrument Flash protocol: Pre-vac, 270° F, 10 min exposure, 1 min drying, 2.) One Tray OR protocol: Pre-vac, 270° F, 4 min exposure, 1 min drying, and 3.) Standard Post-Operative protocol: Pre-vac, 270° F, 10 min exposure, 60 min drying. Control coupons did not undergo autoclaving. Coupons were then sonicated for 30 minutes in tryptic soy broth and plated to count CFUs. Experiments were performed in quadruplicate. Control coupons showed significant contamination with CFU counts in the range of 10. 6. CFU/mL. CFU counts of zero across all autoclaved PMMA and CC coupons revealed that each protocol was effective in completely eradicating culturable S. aureus, confirming clinical
The postoperative pain after hip arthroscopy remains a major challenge in the immediate postoperative period. Adequate postoperative analgesia has been associated with increased patient satisfaction and decreased consumption of opioids. We evaluated the
Patients undergoing total hip or knee arthroplasty (THA/TKA) are commonly associated with high pain scores and narcotic use. Duloxetine is effective in relieving chronic pain. The aim of this study was to evaluate the safety and
The purpose of our study is to examine the outcome of patients undergoing outpatient total hip arthroplasty with a BMI >35. Case-control matching on age, gender (46% female;54%male), and ASA (mean 2.8) with 51 outpatients BMI≥35 kg/m2 (mean of 40 (35–55)), mean age of 61 (38–78) matched to 51 outpatients BMI<35 kg/m2 (mean of 27 (17–34)) mean age 61 (33–78). Subsequently 47 inpatients BMI≥35 kg/m2 (mean of 40 (35–55)) mean age 62 (34–77) were matched outpatients BMI≥35 kg/m2. For each cohort, adverse events, readmission in 90 days, reoperations were recorded. Rate of adverse events was significantly higher in BMI ≥35: 15.69% verus 1.96% (p=0.039) with 5 reoperations in the BMI≥35 cohort vs 0 in the BMI<35 kg/m2 (p= 0.063). Readmissions did not differ between groups (p=0.125). No significant difference for all studied outcomes between the outpatient and inpatients cohorts with BMI≥35 kg/m2. The most complications requiring surgery/medical intervention (3B) were in the inpatient cohort of patients >35. The prevalence of Diabetes and Obstructive Sleep apnea was 21.6% and 29.4% for BMI>35 compared to 9.8% and 11.8%, for BMI <35, respectively. Severely obese patients have an overall higher rate of adverse events and reoperations however it should not be used a sole variable for deciding if the patient should be admitted or not.
Objectives. The primary purpose of this meta-analysis was to determine whether statin usage could reduce the risk of glucocorticoid-related osteonecrosis in animal models. Methods. A systematic literature search up to May 2015 was carried out using the PubMed, Ovid, EBM reviews, ISI Web of Science, EBSCO, CBM, CNKI databases with the term and boolean operators: statins and osteonecrosis in all fields. Risk ratio (RR), as the risk estimate of specific outcome, was calculated along with 95% confidence intervals (CI). The methodological quality of individual studies was assessed using a quantitative tool based on the updated Stroke Therapy Academic Industry Roundtable (STAIR) recommendations. Results. A total of 11 eligible studies were included according to predetermined criteria. The pooled data demonstrated that animals with statin usage, either alone or combined with other treatments, were at a decreased risk of developing glucocorticoid-related osteonecrosis (RR = 2.06, 95% confidence interval (CI) 1.71 to 2.50). Moreover, subgroup analysis revealed that compared with statins alone, statins combined with other treatments significantly decreased the risk of osteonecrosis (RR = 1.23, 95% CI 1.02 to 1.47). However, we could find no significant risk difference for different gender, or for different time points. Conclusions. The present study suggests that statins combined with other treatments are efficient in preventing the development of glucocorticoid-related osteonecrosis in animals. These results might shed light on clinical practice when glucocorticoids are prescribed, and could be further investigated in high-quality clinical trials. Cite this article: Z. Yang, H. Liu, D. Li, X. Xie, T. Qin, J. Ma, P. Kang. The
Introduction. In early stage osteonecrosis of the femoral head (ONFH), core decompression (CD) is often performed; however, approximately 30% of CD cases progress to femoral head collapse. Bone healing can be augmented by preconditioning MSCs (pMSCs) with inflammatory cytokines. Another immunomodulatory approach is the timely resolution of inflammation using cytokines such as IL-4. We investigated the
Introduction. We studied the safety and
Comparison of the safety and
Periprosthetic joint infection (PJI) causes significant morbidity. Methicillin sensitive Our hospital trust introduced MSSA screening and decolonisation prior to hip and knee arthroplasty in 2010. Data was prospectively collected since 2013, including all MSSA carriers, decolonisation treatment received, MSSA status at time of surgery and all PJIs. Prior to 2017 MSSA carriers received nasal mupirocin or neomycin, from August 2017 until August 2019 nasal octenidine was used. During the study period 15,958 primary hip and knee replacements were performed. 3,200 (20.1%) were MSSA positive at preoperative screening and received decolonisation treatment, 698 mupirocin, 1,210 neomycin and 1,221 octenidine. Mupirocin (89.1%) and neomycin (90.9%) were more effective at decolonisation than octenidine (50.0%, P<0.0001). There was no difference in S. aureus PJI rates (P=0.452). Of those negative at original screening 9.1% were positive on the day of surgery (1,164/12,758). MSSA decolonisation is an effective method to decrease PJI rates but there is little research into the best treatment. Both mupirocin and neomycin are more effective than octenidine at achieving MSSA decolonisation. There was poor correlation between the MSSA status after treatment and PJI rates. There is debate if treatment should be targeted by screening or if all patients she be treated without screening. Global decolonisation without screening is supported by the 26.7% of carriers that were negative at original screening in our study. Further research is needed comparing decolonisation treatments to reduce PJI rates and avoid the risk of drug resistance.
Aims. Cementless primary total hip arthroplasty (THA) is associated with risks of bleeding and thromboembolism. Anticoagulants are effective as venous thromboprophylaxis, but with an increased risk of bleeding. Tranexamic acid (TXA) is an efficient antifibrinolytic agent, but the mode and timing of its administration remain controversial. This study aimed to determine whether two intravenous (IV) TXA regimens (a three-hour two-dose (short-TXA) and 11-hour four-dose (long-TXA)) were more effective than placebo in reducing perioperative real blood loss (RBL, between baseline and day 3 postoperatively) in patients undergoing THA who receive rivaroxaban as thromboprophylaxis. The secondary aim was to assess the non-inferiority of the reduction of blood loss of the short protocol versus the long protocol. Patients and Methods. A multicentre, prospective, randomized, double-blind, placebo-controlled trial was undertaken involving 229 patients undergoing primary cementless THA using a posterior approach, whose extended rivaroxaban thromboprophylaxis started on the day of surgery. There were 98 male and 131 female patients, with a mean age of 65.5 years (32 to 91). The primary outcome, perioperative RBL, was evaluated at 72 hours postoperatively. The
Objectives. Fractures of the proximal femur are a common clinical problem, and a number of orthopaedic devices are available for the treatment of such fractures. The objective of this study was to assess the rotational stability, a common failure predictor, of three different rotational control design philosophies: a screw, a helical blade and a deployable crucifix. Methods. Devices were compared in terms of the mechanical work (W) required to rotate the implant by 6° in a bone substitute material. The substitute material used was Sawbones polyurethane foam of three different densities (0.08 g/cm. 3. , 0.16 g/cm. 3. and 0.24 g/cm. 3. ). Each torsion test comprised a steady ramp of 1°/minute up to an angular displacement of 10°. Results. The deployable crucifix design (X-Bolt), was more torsionally stable, compared to both the dynamic hip screw (DHS, p = 0.008) and helical blade (DHS Blade, p= 0.008) designs in bone substitute material representative of osteoporotic bone (0.16 g/cm. 3. polyurethane foam). In 0.08 g/cm. 3. density substrate, the crucifix design (X-Bolt) had a higher resistance to torsion than the screw (DHS, p = 0.008). There were no significant differences (p = 0.101) between the implants in 0.24 g/cm. 3. density bone substitute. Conclusions. Our findings indicate that the clinical standard proximal fracture fixator design, the screw (DHS), was the least effective at resisting torsional load, and a novel crucifix design (X-Bolt), was the most effective design in resisting torsional load in bone substitute material with density representative of osteoporotic bone. At other densities the torsional stability was also higher for the X-Bolt, although not consistently significant by statistical analysis. Cite this article: J. D. Gosiewski, T. P. Holsgrove, H. S. Gill. The
Greater trochanteric pain syndrome is a painful condition characterised by pain around the greater trochanter usually affecting middle-aged women. The majority of patients will improve with conservative management such as physiotherapy and non-steroidal anti-inflammatory drugs (NSAIDs); however, if this fails then more invasive treatments including corticosteroids and surgery may be required. Platelet-rich plasma (PRP) is an autologous blood product, which has a higher concentration of growth factors postulated to provide enhanced healing and anti-inflammatory properties. The Hip Injections PRP Vs Placebo (HIPPO) trial aims to assess the ability of ultrasound-guided PRP injections to improve symptoms and function in patients with GTPS. 64 patients were enrolled and randomised to either the PRP or placebo (normal saline) treatment arm. Two patients decided to drop out of the trial. Clinical outcomes in both groups were evaluated and compared using the International Hip Outcome Tool-12 (iHOT12), Visual Analogue Scale (VAS) of pain, the modified Harris Hip Score (mHHS) and the presence or absence of complications at 3 and six months. The level of significance was set at p<0.05. Both groups received physiotherapy after the injections. The mean age was 57.5. There were 6 males and 56 females with M:F ratio of 1:9.3. Both groups were similar in terms of demography and preoperative scores. The iHOT12 score improved from 28.23 to 45.42 at three-months and decreased slightly to 42.44 at six-months in the Placebo group. The iHOT12 in the PRP group improved from 35.51 to 44.47 at three-months and decreased to 39.78 at six-months. Both groups showed improved VAS and mHHS at three-months compared to the baseline with no statistically significant difference between the two groups (p >0.05). The scores decreased at six-months however remained above the baseline. No complications were reported. Gender and age had no effect on outcomes. Both groups similarly improved from baseline. Physiotherapy can be considered as an important factor in patients' treatment. Further research should be conducted to investigate the role of physiotherapy in the treatment of GTPS.
Image-guided intra-articular hip injection of local-anaesthetic and steroid is commonly used in the management of hip pain. It can be used as a diagnostic and/or therapeutic tool and is of low cost (£75). The aim of this study was to assess how often a hip injection has a therapeutic effect. This is a retrospective, consecutive, case series of intra-articular hip injections performed in a tertiary referral hospital over a 2-year period (2013–4). Patients were identified from the radiology department's prospectively entered database. Clinical information, reason for injection and subsequent management was obtained from hospital records. All patients prospectively reported their pain levels in a numeric pain scale diary (out of 10) at various time points; pre-, immediately post-, 1st day-, 2nd day- and 2 weeks- post-injection. Only patients with complete pain scores at all time points were included (n=200, of the 250 injections performed over study period, 80%). The majority of injections were performed for osteoarthritis (OA) treatment (82%). The pain was significantly reduced from a pre-injection score of 7.5 (SD:2) to 5.0 (SD:3) immediately post-injection(p<0.001); only 24 (11%) reported any worsening of pain immediately post-injection. Pain significantly reduced further to 3.8(SD:3) at 2-weeks post-injection (p<0.001). 50% of patients had at least a 3 point drop in reported pain. No improvement was seen in 18 patients and 10 (5%) reported worse pain at 2-weeks compared to pre-injection. Of the OA cohort, 10% have required repeat injections, 45% required no further intervention and 45% underwent or are due for hip replacement. No immediate complications occurred. Intra-articular hip injection reduced pain in 86% of cases and has delayed any further surgical treatment for at least 2 years in over 50% of OA cases. It is hence a cost-effective treatment modality. Further work is necessary to describe factors predicting response.
Aims. This study was designed to develop a model for predicting bone mineral density (BMD) loss of the femur after total hip arthroplasty (THA) using artificial intelligence (AI), and to identify factors that influence the prediction. Additionally, we virtually examined the
Superior team performance in surgery leads to fewer technical errors, reduced mortality, and improved patient outcomes. Scrub nurses are a pivotal part of this team, however they have very little structured training, leading to high levels of stress, low confidence, inefficiency, and potential for harm. Immersive virtual reality (iVR) simulation has demonstrated excellent
Aims. The aims of this study were to validate the Forgotten Joint Score-12 (FJS-12) in the postoperative evaluation of periacetabular osteotomy (PAO), identify factors associated with joint awareness after PAO, and determine the FJS-12 threshold for patient-acceptable symptom state (PASS). Methods. Data from 686 patients (882 hips) with hip dysplasia who underwent transposition osteotomy of the acetabulum, a type of PAO, between 1998 and 2019 were reviewed. After screening the study included 442 patients (582 hips; response rate, 78%). Patients who completed a study questionnaire consisting of the visual analogue scale (VAS) for pain and satisfaction, FJS-12, and Hip disability and Osteoarthritis Outcome Score (HOOS) were included. The ceiling effects, internal consistency, convergent validity, and PASS thresholds of FJS-12 were investigated. Results. The median follow-up was 12 years (interquartile range 7 to 16). The ceiling effect of FJS-12 was 7.2%, the lowest of all the measures examined. FJS-12 correlated with all HOOS subscales (ρ = 0.72 to 0.77, p < 0.001) and pain and satisfaction-VAS (ρ = -0.63 and 0.56, p < 0.001), suggesting good convergent validity. Cronbach’s α was 0.95 for the FJS-12, which indicated excellent internal consistency. The median FJS-12 score for preoperative Tönnis grade 0 hips (60 points) was higher than that for grade 1 (51 points) or 2 (46 points). When PASS was defined as pain-VAS < 21 and satisfaction-VAS ≥ 77, the FJS-12 threshold that maximized the sensitivity and specificity for detecting PASS was 50 points (area under the curve (AUC) = 0.85). Conclusion. Our results suggest that FJS-12 is a valid and reliable assessment tool for patients undergoing PAO, and the threshold of 50 points may be useful to determine patient satisfaction following PAO in clinical settings. Further investigation of the factors influencing postoperative joint awareness may enable improved prediction of treatment
Aims. Successful cell therapy in hip osteonecrosis (ON) may help to avoid ON progression or total hip arthroplasty (THA), but the achieved bone regeneration is unclear. The aim of this study was to evaluate amount and location of bone regeneration obtained after surgical injection of expanded autologous mesenchymal stromal cells from the bone marrow (BM-hMSCs). Methods. A total of 20 patients with small and medium-size symptomatic stage II femoral head ON treated with 140 million BM-hMSCs through percutaneous forage in the EudraCT 2012-002010-39 clinical trial were retrospectively evaluated through preoperative and postoperative (three and 12 months) MRI. Then, 3D reconstruction of the original lesion and the observed postoperative residual damage after bone regeneration were analyzed and compared per group based on treatment
Aims. The aim of the HIPGEN consortium is to develop the first cell therapy product for hip fracture patients using PLacental-eXpanded (PLX-PAD) stromal cells. Methods. HIPGEN is a multicentre, multinational, randomized, double-blind, placebo-controlled trial. A total of 240 patients aged 60 to 90 years with low-energy femoral neck fractures (FNF) will be allocated to two arms and receive an intramuscular injection of either 150 × 10. 6. PLX-PAD cells or placebo into the medial gluteal muscle after direct lateral implantation of total or hemi hip arthroplasty. Patients will be followed for two years. The primary endpoint is the Short Physical Performance Battery (SPPB) at week 26. Secondary and exploratory endpoints include morphological parameters (lean body mass), functional parameters (abduction and handgrip strength, symmetry in gait, weightbearing), all-cause mortality rate and patient-reported outcome measures (Lower Limb Measure, EuroQol five-dimension questionnaire). Immunological biomarker and in vitro studies will be performed to analyze the PLX-PAD mechanism of action. A sample size of 240 subjects was calculated providing 88% power for the detection of a 1 SPPB point treatment effect for a two-sided test with an α level of 5%. Conclusion. The HIPGEN study assesses the
In primary total hip arthroplasty (THA) for patients with Crowe II or higher classes developmental dysplasia of the hip (DDH) or rapidly destructive coxopathy (RDC), the placement of the cup can be challenging due to superior and lateral acetabular bone defects. Traditionally, bone grafts from resected femoral heads were used to fill these defects, but bulk graft poses a risk of collapse, especially in DDH with hypoplastic femoral heads or in RDC where good quality bone is scarce. Recently, porous metal augments have shown promising outcomes in revision surgeries, yet reports on their
The SPAIRE technique (Saving Piriformis And Internus, Repair Externus) was first described in 2016 and an approach to the hip in the interval between the inferior gemellus and quadratus femoris can be used for both hemi- and total hip arthroplasty. The HemiSPAIRE technique in hip hemiarthroplasty for displaced intracapsular fractures has been compared with the standard lateral approach (advocated by NICE) in a pragmatic, superiority, multicentre, randomised controlled trial into postoperative mobility and function. This NIHR funded study was recruited between November 2019 and April 2022 and the results are reported in this presentation. The author has used the SPAIRE technique in 1026 routine primary total hip replacements since February 2016. The technique is described along with results from NJR data. SPAIRE is most challenging in patients with small anatomy, reduced offset, with an external rotation deformity. Particularly in these, but in all cases, MAKO robotic assistance facilitates accurate implantation of prostheses and precise recreation of biomechanics. The MAKO robot has been used in all cases since 2018 and SPAIRE/MAKO is now the standard of care in the author's practice. To evaluate whether robotic-assisted tendon-sparing posterior approaches (piriformis sparing and SPAIRE), improve patient outcomes in total hip arthroplasty compared with a robotic-assisted standard posterior approach, the NIHR