Purpose. Ultrasound of the neonatal and infantile hip is a useful tool in diagnosis and treatment of the developmental dysplasia of the hip (DDH), especially given the fact that numerous cases of
Introduction. Selective screening of children at risk for developmental dysplasia of the hip (DDH) is based on clinical examination and risk factor identification. Two meta-analyses published in 2012 found breech presentation, family history of
Abstract. Objectives. The purpose of this study was to determine the cost of inpatient admissions for developmental dysplasia of the hip (DDH) at a UK tertiary referral centre, and identify any association between newborn screening (NIPE) status and the cost of treatment. Methods. This was a retrospective study, using hospital episodes data from a single NHS trust. All inpatient episodes between 01/01/2014 to 30/06/2019 with an ICD-10 code stem of Q65 ‘congenital deformities of hip’ were screened to identify admissions for management of
Abstract. OBJECTIVES. Cam femoroacetabular impingement (FAI – femoral head-neck deformity) and developmental dysplasia of the hip (DDH – insufficient acetabular coverage) constitute a large portion of adverse hip loading and early degeneration. Spinopelvic anatomy may play a role in hip stability thus we examined which anatomical relationships can best predict range of motion (ROM). METHODS. Twenty-four cadaveric hips with cam FAI or
Late presentation of
In patients with developmental dysplasia of the hip (DDH) chronic joint dislocation induces remodeling of the soft tissue with contractures, muscle atrophy, especially of the hip abductors muscles, leading to severe motor dysfunction, pain and disability (1). The aim pf the present work is to explore if a correct positioning of the prosthetic implants through 3D skeletal modeling surgical planning technologies and an adequate customized rehabilitation can be beneficial for patients with
The pathology of the posterior acetabular legion in femoroacetabular impingement (FAI) syndrome, so called “contre-coup region”, is still unclear. . 18. F-fluoride positron emission tomography (PET) is a functional imaging modality, which reflects the osteoblast activity. Recent technological advances in PET combined with computed tomography (CT) imaging allowed us to obtain detailed 3-dimensional (3D) morphological information. We evaluated the abnormal uptake of . 18. F-fluoride PET/CT on posterior acetabular lesion in FAI syndrome cases. We enrolled forty-one hips from 41 patients who were diagnosed as FAI syndrome and were performed . 18. F-fluoride PET/CT between October 2014 and October 2016. In each hip, the maximum standardized uptake value (SUV. max. ) on the posterior acetabular was measured. The cases were divided into 4 groups; cam-type (11 cases), pincer-type (7), combined-type (11), dysplastic developmental hip (DDH) with cam morphology (12). The average SUV. max. of the pincer-type was significantly smaller than that of the other 3 groups (p < .05). The percentage of the cases with SUV. max. ≥ 6 was 81.8% in cam-type, 28.6% in pincer-type, 90.9% in combined-type, 91.7% in
Developmental dysplasia of the hip (DDH) is the most common post-natal skeletal abnormality. It is widely acknowledged that conditions which cause or result in reduced movement in utero are contributing factors to the incidence of
The Trident acetabular system is the second most common cementless cup implanted in the UK. Recent studies have shown that malseating of the liner can be as high as 16.4%. We felt this was very high and were prompted to review our series and early clinical outcomes. We reviewed 118 hips in 110 patients, implanted between from 2005-2007. We reviewed initial post operative X-rays using the technique described by Howcroft to identify malseating. The posterior approach was used in all cases. All cups were Trident PSL and all 85 Patients had OA, 10 RA, 8 AVN, 5
We studied the morphometry of 35 femora from 31 female patients with developmental dysplasia of the hip (DDH) and another 15 from 15 age- and sex-matched control patients using CT and three-dimensional computer reconstruction models. According to the classification of Crowe et al 15 of the dysplastic hips were graded as class I (less than 50% subluxation), ten as class II/III (50% to 100% subluxation) and ten as class IV (more than 100% subluxation). The femora with
Repeat revision hip replacements can lead to severe bone loss necessitating salvage procedures such as proximal or total femoral replacement. We present medium term outcomes from our experience of the Limb Preservation System (LPS) in patients with failed revision hip arthroplasties. All patients undergoing proximal femoral or total femoral replacement from 2003–2007 at our unit were reviewed. Data was collected preoperatively and at annual assessment post procedure for a minimum of 5 years. This included clinical review, functional outcome scores (WOMAC, Oxford Hip Score, Harris Hip Score) and radiographic evaluation. A total of 17 patients underwent femoral replacement (13 proximal, 4 total) using the LPS during the study period. Within this cohort there were 13 males and 4 females with a mean age of 64 years (range 47–86). Median follow up was 7 years (range 5–9 years). Primary diagnoses were
Native anatomy of the arthritic hip is an important consideration in hip replacement surgery and implant design. Acetabular component orientation in total hip replacement (THR) is the single greatest factor that influences dislocation rate. Detailed knowledge regarding orientation of the native acetabulum is therefore essential. Native acetabular orientation in healthy hips is well documented but we could not find any papers detailing native acetabular orientation in the arthritic hip. A commercially available computer navigation system (Orthopilot BBraun Aesculap, Tuttlingen, Germany) was used to assess acetabular inclination and anteversion in 65 hips with symptomatic arthritis requiring THR. Acetabular inclination in all hips was also measured on pre op anteroposterior pelvic radiographs. Patients with
We have previously investigated an association between the genome copy number variation (CNV) and acetabular dysplasia (AD). Hip osteoarthritis is associated with a genetic polymorphism in the aspartic acid repeat in the N-terminal region of the asporin ( Acetabular coverage of all subjects was evaluated using radiological findings (Sharp angle, centre-edge (CE) angle, acetabular roof obliquity (ARO) angle, and minimum joint space width). Genomic DNA was extracted from peripheral blood leukocytes. Agilent’s region-targeted high-density oligonucleotide tiling microarray was used to analyse 64 female AD patients and 32 female control subjects. All statistical analyses were performed using EZR software (Fisher’s exact probability test, Pearson’s correlation test, and Student’s Objectives
Methods
Acetabular component orientation in total hip arthroplasty (THA)
influences results. Intra-operatively, the natural arthritic acetabulum
is often used as a reference to position the acetabular component.
Detailed information regarding its orientation is therefore essential. The
aim of this study was to identify the acetabular inclination and
anteversion in arthritic hips. Acetabular inclination and anteversion in 65 symptomatic arthritic
hips requiring THA were measured using a computer navigation system.
All patients were Caucasian with primary osteoarthritis (29 men,
36 women). The mean age was 68 years (SD 8). Mean inclination was
50.5° (SD 7.8) in men and 52.1° (SD 6.7) in women. Mean anteversion
was 8.3° (SD 8.7) in men and 14.4° (SD 11.6) in women. Objectives
Methods