Abstract
Repeat revision hip replacements can lead to severe bone loss necessitating salvage procedures such as proximal or total femoral replacement. We present medium term outcomes from our experience of the Limb Preservation System (LPS) in patients with failed revision hip arthroplasties.
All patients undergoing proximal femoral or total femoral replacement from 2003–2007 at our unit were reviewed. Data was collected preoperatively and at annual assessment post procedure for a minimum of 5 years. This included clinical review, functional outcome scores (WOMAC, Oxford Hip Score, Harris Hip Score) and radiographic evaluation.
A total of 17 patients underwent femoral replacement (13 proximal, 4 total) using the LPS during the study period. Within this cohort there were 13 males and 4 females with a mean age of 64 years (range 47–86). Median follow up was 7 years (range 5–9 years). Primary diagnoses were DDH (7), Primary OA (5), RA (2), proximal femoral fracture (2) and phocomelia (1). Five patients (29%) required further revision surgery for infection (2 patients) or recurrent dislocations (3 patients). No stems required revision due to aseptic loosening or stem failure at 5–9 years. Compared to preoperative assessment, there was significant improvement in median outcome scores at 5 years (WOMAC increased by 33 points, Oxford hip score by16 points and Harris hip score by 43 points). 82% of patients maintained functional independence at latest review.
The Limb Preservation System offers a salvage procedure for failed revision total hip arthroplasty with significant symptom and functional improvement in most patients at medium term follow up.