Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Research

MALSEATING OF THE TRIDENT ACETABULAR LINER IN HYBRID TOTAL HIP REPLACEMENT

West of Scotland Orthopaedic Research Society (WOSORS) - 4th Annual Meeting



Abstract

The Trident acetabular system is the second most common cementless cup implanted in the UK. Recent studies have shown that malseating of the liner can be as high as 16.4%. We felt this was very high and were prompted to review our series and early clinical outcomes.

We reviewed 118 hips in 110 patients, implanted between from 2005-2007. We reviewed initial post operative X-rays using the technique described by Howcroft to identify malseating. The posterior approach was used in all cases. All cups were Trident PSL and all 85 Patients had OA, 10 RA, 8 AVN, 5 DDH, 3 OA post trauma, 2 Perthes, 2 Psoriatic Arthritis, 3 other. We only identified 3 malseated cups in 118 hips. 2 were in patients with OA secondary to trauma and 1 in primary OA. The rate of malseating for trainees operating was 5 % and only 1% when consultants were operating. There were no adverse events in these patients. No-one required revision. Oxford Hip Score (OHS) improved from 47 pre-op to 20 post op. This was compared to 47 and 22 in the correctly seated group (115 cases). Surprisingly the subgroup with the poorest OHS at 1 year had surgery for DDH, with a mean OHS of 31. The reasons for this are unclear.

Contrary to other studies our malseating rate is very low. We do not feel that malseating is a problem with Trident if adequate exposure is obtained. In those patients with sclerotic bone, we suggest over reaming the rim of the acetabulum by 1mm to avoid excess deformation of the shell which may lead to difficulty with seating the liner. We suggest trainees are supervised closely when using Trident.