Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 37 - 37
1 Jun 2012
Mizu-Uchi H Flores-Hernandez C Colwell C Steklov N Matsuda S Iwamoto Y D'Lima D
Full Access

INTRODUCTION

Knee contact force during activities after total knee arthroplasty (TKA) is very important, since it directly affects component wear and implant loosening. While several computational models have predicted knee contact force, the reports vary widely based on the type of modeling approach and the assumptions made in the model. The knee is a complex joint, with three compartments of which stability is governed primarily by soft tissues. Multiple muscles control knee motion with antagonistic co-contraction and redundant actions, which adds to the difficulty of accurate dynamic modeling. For accurate clinically relevant predictions a subject-specific approach is necessary to account for inter-patient variability.

METHODS

Data were collected from 3 patients who received custom TKA tibial prostheses instrumented with force transducers and a telemetry system. Knee contact forces were measured during squatting, which was performed up to a knee flexion angle that was possible without discomfort (range, 80–120°). Skin marker-based video motion analysis was used to record knee kinematics. Preoperative CT scans were reconstructed to extract tibiofemoral bone geometry using MIMICS (Materialise, Belgium). Subject-specific musculoskeletal models of dynamic squatting were generated in a commercial software program (LifeMOD, LifeModeler, USA). Contact was modeled between tibiofemoral and patellofemoral articular surfaces and between the quadriceps and trochlear groove to simulate tendon wrapping. Knee ligaments were modeled with nonlinear springs: the attachments of these ligaments were adjusted to subject-specific anatomic landmarks and material properties were assigned from published reports.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 103 - 103
23 Feb 2023
Gupta V Van Niekerk M Hirner M
Full Access

Scapular notching is a common problem following reverse shoulder arthroplasty (RSA). This is due to impingement between the humeral polyethylene cup and scapular neck in adduction and external rotation. Various glenoid component strategies have been described to combat scapular notching and enhance impingement-free range of motion (ROM). There is limited data available detailing optimal glenosphere position in RSA with an onlay configuration. The purpose of this study was to determine which glenosphere configurations would maximise impingement free ROM using an onlay RSA prosthesis. A three-dimensional (3D) computed tomography (CT) scan of a shoulder with Walch A1, Favard E0 glenoid morphology was segmented using validated software. An onlay RSA prosthesis was implanted and a computer model simulated external rotation and adduction motion of the virtual RSA prosthesis. Four glenosphere parameters were tested; diameter (36mm, 41mm), lateralization (0mm, 3mm, 6mm), inferior tilt (neutral, 5 degrees, 10 degrees), and inferior eccentric positioning (0.5mm, 1.5mm. 2.5mm, 3.5mm, 4.5mm). Eighty-four combinations were simulated. For each simulation, the humeral neck-shaft angle was 147 degrees and retroversion was 30 degrees. The largest increase in impingement-free range of motion resulted from increasing inferior eccentric positioning, gaining 15.0 degrees for external rotation and 18.8 degrees for adduction. Glenosphere lateralization increased external rotation motion by 13. 6 degrees and adduction by 4.3 degrees. Implanting larger diameter glenospheres increased external rotation and adduction by 9.4 and 10.1 degrees respectively. Glenosphere tilt had a negligible effect on impingement-free ROM. Maximizing inferior glenosphere eccentricity, lateralizing the glenosphere, and implanting larger glenosphere diameters improves impingement-free range of motion, in particular external rotation, of an onlay RSA prosthesis. Surgeons’ awareness of these trends can help optimize glenoid component position to maximise impingement-free ROM for RSA. Further studies are required to validate these findings in the context of scapulothoracic motion and soft tissue constraints


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 45 - 45
1 Feb 2020
Delgadillo L Jones H Noble PC
Full Access

Background. Cementless Total Knee Arthroplasty has been developed to reduce the incidence of failure secondary to aseptic loosening, osteolysis and stress-induced osteopenia, especially in younger and more active patients. However, failures are still more common compared to cemented components, especially those involving the tibia. It is hypothesized that this is caused by incomplete contact between the tibial tray and the underlying bony surface due to: (i) inadequate flatness of the tibial osteotomy, or (ii) failure of implantation to spread the area of contact over the exposed cancellous surface. In the present study we compare the contact area developed during implantation of a cementless tray as a function of the initial flatness of the tibial osteotomy. Method. Eight joint replacement surgeons prepared 14 cadaveric knees for cementless TKR using a standard instrumentation set (ZimmerBiomet Inc). The tibial osteotomy was created using an oscillating bone saw and a 1.27mm blade (Stryker Inc) directed by a slotted cutting guide mounted on an extramedullary rod and fixed to the tibia with pins and screws. The topography of the exposed cancellous surface was captured with a commercial laser scanner (Faro Inc, Halifax, approx. 33,000 surface points). 3D computer models of each tibial surface were generated in a CAD environment (Rapidform, Inuus). After scanning, a cementless tibial tray was implanted on the prepared tibial surface using a manual impactor. The tray-tibia constructs were dissected free of soft tissue, embedded in mounting resin, and sectioned with a diamond wafering saw. Points of bone-tray contact and interface separation were identified by stereomicroscopy and incorporated in the 3D computer models. Maps were generated depicting contacting and non-contacting areas Each model was subdivided into 7 zones for characterizing the distribution of interface contact in terms of anatomic location. Results. The flatness for the tibial osteotomies averaged 1.1±0.35 mm (range: 0.56–1.81mm). After impaction, 79.8±0.3% of the tibial surface had plastically deformed to establish a contacting interface with the implant. 15.1% of the bony surface was within 0.2mm of the tray and 17.6% was within 0.3mm. Gaps large enough to impede ingrowth only occupied 2.6% of the exposed tibial These non-contacting areas were typically located centrally at the ACL, PCL and canal zones. There was an inverse linear relationship between the initial flatness of the tibial osteotomy and the percentage of tray-bone contact. Conclusions. The amount of direct contact between the bone and implant is critical for the development of stability in cementless fixation. We found a relationship between ultimate bony contact and initial flatness. However, we also found that during impaction of the implant, bony contact increased through deformation of the most prominent peaks of the cancellous surface. Interface gaps were consistently observed in central areas of the tibia surface located above the medullary canal which may be reduced through selection of trays with distal keels. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 89 - 89
1 Dec 2022
Koucheki R Lex J Morozova A Ferri D Hauer T Mirzaie S Ferguson P Ballyk B
Full Access

Novel immersive virtual reality (IVR) technologies are revolutionizing medical education. Virtual anatomy education using head-mounted displays allows users to interact with virtual anatomical objects, move within the virtual rooms, and interact with other virtual users. While IVR has been shown to be more effective than textbook learning and 3D computer models presented in 2D screens, the effectiveness of IVR compared to cadaveric models in anatomy education is currently unknown. In this study, we aim to compare the effectiveness of IVR with direct cadaveric bone models in teaching upper and lower limb anatomy for first-year medical students. A randomized, double-blind crossover non-inferiority trial was conducted. Participants were first-year medical students from a single University. Exclusion criteria included students who undertook prior undergraduate or graduate degrees in anatomy. In the first stage of the study, students were randomized in a 1:1 ratio to IVR or cadaveric bone groups studying upper limb skeletal anatomy. All students were then crossed over and used cadaveric bone or IVR to study lower limb skeletal anatomy. All students in both groups completed a pre-and post-intervention knowledge test. The educational content was based on the University of Toronto Medical Anatomy Curriculum. The Oculus Quest 2 Headsets (Meta Technologies) and PrecisionOS Anatomy application (PrecisionOS Technology) were utilized for the virtual reality component. The primary endpoint of the study was student performance on the pre-and post-intervention knowledge tests. We hypothesized that student performance in the IVR groups would be comparable to the cadaveric bone group. 50 first-year medical students met inclusion criteria and were computer randomized (1:1 ratio) to IVR and cadaveric bone group for upper limb skeletal anatomy education. Forty-six students attended the study, 21 completed the upper limb modules, and 19 completed the lower limb modules. Among all students, average score on the pre-intervention knowledge test was 14.6% (Standard Deviation (SD)=18.2%) and 25.0% (SD=17%) for upper and lower limbs, respectively. Percentage increase in students’ scores between pre-and post-intervention knowledge test, in the upper limb for IVR, was 15 % and 16.7% for cadaveric bones (p = 0. 2861), and for the lower limb score increase was 22.6% in the IVR and 22.5% in the cadaveric bone group (p = 0.9356). In this non-inferiority crossover randomized controlled trial, we found no significant difference between student performance in knowledge tests after using IVR or cadaveric bones. Immersive virtual reality and cadaveric bones were equally effective in skeletal anatomy education. Going forward, with advances in VR technologies and anatomy applications, we can expect to see further improvements in the effectiveness of these technologies in anatomy and surgical education. These findings have implications for medical schools having challenges in acquiring cadavers and cadaveric parts


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 9 - 9
1 Dec 2022
Koucheki R Lex J Morozova A Ferri D Hauer T Mirzaie S Ferguson P Ballyk B
Full Access

Novel immersive virtual reality (IVR) technologies are revolutionizing medical education. Virtual anatomy education using head-mounted displays allows users to interact with virtual anatomical objects, move within the virtual rooms, and interact with other virtual users. While IVR has been shown to be more effective than textbook learning and 3D computer models presented in 2D screens, the effectiveness of IVR compared to cadaveric models in anatomy education is currently unknown. In this study, we aim to compare the effectiveness of IVR with direct cadaveric bone models in teaching upper and lower limb anatomy for first-year medical students. A randomized, double-blind crossover non-inferiority trial was conducted. Participants were first-year medical students from a single University. Exclusion criteria included students who undertook prior undergraduate or graduate degrees in anatomy. In the first stage of the study, students were randomized in a 1:1 ratio to IVR or cadaveric bone groups studying upper limb skeletal anatomy. All students were then crossed over and used cadaveric bone or IVR to study lower limb skeletal anatomy. All students in both groups completed a pre-and post-intervention knowledge test. The educational content was based on the University of Toronto Medical Anatomy Curriculum. The Oculus Quest 2 Headsets (Meta Technologies) and PrecisionOS Anatomy application (PrecisionOS Technology) were utilized for the virtual reality component. The primary endpoint of the study was student performance on the pre-and post-intervention knowledge tests. We hypothesized that student performance in the IVR groups would be comparable to the cadaveric bone group. 50 first-year medical students met inclusion criteria and were computer randomized (1:1 ratio) to IVR and cadaveric bone group for upper limb skeletal anatomy education. Forty-six students attended the study, 21 completed the upper limb modules, and 19 completed the lower limb modules. Among all students, average score on the pre-intervention knowledge test was 14.6% (Standard Deviation (SD)=18.2%) and 25.0% (SD=17%) for upper and lower limbs, respectively. Percentage increase in students’ scores between pre-and post-intervention knowledge test, in the upper limb for IVR, was 15 % and 16.7% for cadaveric bones (p = 0. 2861), and for the lower limb score increase was 22.6% in the IVR and 22.5% in the cadaveric bone group (p = 0.9356). In this non-inferiority crossover randomized controlled trial, we found no significant difference between student performance in knowledge tests after using IVR or cadaveric bones. Immersive virtual reality and cadaveric bones were equally effective in skeletal anatomy education. Going forward, with advances in VR technologies and anatomy applications, we can expect to see further improvements in the effectiveness of these technologies in anatomy and surgical education. These findings have implications for medical schools having challenges in acquiring cadavers and cadaveric parts


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 118 - 118
1 May 2016
Walker P Arno S Borukhov I Bell C Salvadore G
Full Access

Introduction. The major function of the medial meniscus has been shown to be distribution of the load with reduction of cartilage stresses, while its role in AP stability has been found to be secondary. However several recent studies have shown that cartilage loss in OA occurs in the central region of the tibia while the meniscus is displaced medially. In a lab study (Arno, Hadley 2013) it was confirmed that the AP laxity was greatly reduced with a compressive force across the knee, while the femur shifted posteriorly and the AP laxity was increased after a partial meniscetomy of the posterior horn. It is therefore possible that under load, the compression of the meniscus and the cartilage, 2–3mm in total, allows load transmission on the central tibial plateau, and causes radial expansion and tension of the meniscus providing restraint to femoral displacements. This leads to our hypotheses that the highest loading on the medial meniscus would be at the extremes of motion, rather than in the mid-range, and that the meniscus would provide the majority of the restraint to anterior-posterior femoral displacements throughout flexion when compressive loads were acting. Methods & Materials. MRI scans were taken of ten knee specimens to verify the absence of pathology and produce computer models. The knees were loaded in combinations of compressive and shear loading over a full flexion range. Tekscan sensors were used to measure the pressure distribution across the joint as the knee was flexed continuously. A digital camera was used to track the motion, from which femoral-tibial contacts were determined by computer modelling. Load transmission was determined from the Tekscan for the anterior horn, central body, posterior horn, and the uncovered cartilage in the center of the meniscus. An analysis was carried out (Fig 2) to determine the net anterior or posterior shear force carried by the meniscus. Results. For the three types of loading (Fig 1); compression only, compression and anterior shear, compression and posterior shear; between 40–80% of the total load was transmitted through the meniscus, the overall average being 58%. The remaining 42% was transmitted directly through the uncovered cartilage. The anterior horn was loaded only up to 30 degrees flexion, and played a role in controlling anterior femoral displacement. The central body was loaded 10–20% and would provide some restraint to medial femoral subluxation. Overall the posterior horn carried the highest percentage of the shear load (Figure 3), especially after 30 degrees flexion when a posterior shear force was applied, for which the meniscus was estimated to carry 50% of the shear force. Discussion. The hypotheses were largely supported. There was high anterior horn loading in early flexion, but in the remaining range, the posterior horn was the highest loaded especially under posterior shear. Supporting the posterior shear force under load bearing conditions is evidently an important role of the meniscus. Hence in any attempts at repair or replacement, these dual functions of load-sharing and stability need to be incorporated


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 6 - 6
1 Mar 2017
Siggelkow E Sauerberg I Bandi M Drury N
Full Access

INTRODUCTION. Clinical studies have shown that the knee tends to experience laterally higher AP motion (posterior directed) than medially (Asano at al., 2001; Dennis et al., 2005; Hill et al., 2000; Moro Oka et al., 2007). Traditional posterior stabilized (PS) total knee arthroplasty (TKA) designs allow deep flexion stability and femoral rollback once cam/spine engagement occurs, however mechanical stability provided by tibial bearing conformity during early to mid-flexion is highly variable. In this study a computer knee model is used to compare AP kinematics in PS TKA designs while evaluating multiple sagittal tibia bearing conformities. We hypothesized that highly conforming designs would be necessary to promote AP stability prior to cam/spine engagement. METHOD. A specimen specific computer model consisting of the femur, tibia and fibula, as well as the contribution of the ligaments and capsule was virtually implanted with TKA designs of the appropriate size at 5° tibia slope with the posterior cruciate ligament sacrificed. A single PS femoral component was evaluated with five PS tibia bearing designs with variable sagittal conformity ratios ranging from 1.05:1 to 2.2:1 (conformity ratio = tibia bearing sagittal radius / femur sagittal condylar radius). Designs were fully conforming frontally, with cam/spine engagement beyond 90° flexion. In all designs, lateral conformity ratios were increased relative to medial conformity ratios to facilitate lateral femoral rollback. Resultant AP kinematic predictions were obtained for femoral Low Points (LP) during 1) envelope of motion during internal external (IE) laxity evaluation and 2) knee bend functional activity. RESULTS. Designs with increased conformity resulted in improved AP stability in early to mid-flexion. In the envelope of laxity evaluations (Figure 1), the Medial LP laxity was similar for the 1.05:1 and 1.15:1 designs (approximately 2–3mm from extension to flexion), but then increased for the 1.35:1, 1.55:1, and 2.20:1 designs. Lateral LP laxity was more similar in all designs, however the designs with lower medial conformity ratio tended to have a greater Lateral LP laxity. During the Knee Bend activity (Figure 2), minimal (<1mm) Medial LP AP motion occurred from extension to cam/spine engagement in both the 1.05:1 and 1.15:1 designs, and greater AP motion occurred in the remaining designs. DISCUSSION. This study demonstrates that similar knee kinematics in PS TKA can be achieved over a small range of sagittal conformities, when designs approach 1:1 conformity. More conforming medial geometries can lead to greater lateral LP motion, suggesting greater medial conformity is necessary to replicate normal knee kinematics. Further work could evaluate impact of other factors such as tibia slope, further refinement in conformity, and additional specimen sizes. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 7 - 7
1 Mar 2017
Siggelkow E Uthgenannt B Greuter D Sauerberg I Bandi M
Full Access

INTRODUCTION. The intact, healthy human knee joint is stable under anterior-posterior (AP) loading but allows for substantial internal-external (IE) laxity. In vivo clinical studies of the intact knee consistently demonstrate femoral rollback with flexion (Hill et al., 2000, Dennis et al., 2005). A tri-condylar, posterior stabilized (PS) total knee arthroplasty (TKA) with a rotating platform bearing (TKA-A) has been designed to address these characteristics of the intact knee. The third condyle is designed to guide the femoral component throughout the entire flexion arc (AP stability and femoral rollback with flexion), while the rotating platform bearing allows for IE rotation. This study used a computer model to compare the AP and IE laxity of a new TKA-A to that of two clinically established TKAs (TKA-B: rotating PS TKA, TKA-C: fixed PS TKA) and to demonstrate improvements in AP stability, IE rotation, and femoral rollback. METHODS. A specimen-specific, robotically calibrated computer knee model (Siggelkow et al., 2012), consisting of the femur, tibia and fibula as well as the kinetic contribution of the ligaments and capsule was virtually implanted with appropriate sizes of TKA-A, TKA-B and TKA-C adhering to the respective surgical techniques. A similar extension gap was targeted for all designs. The following kinematic data resulting from applied loads and moments were analyzed: 1) Passive AP and IE laxity (AP load: ± 50 N, IE moment: ± 6 Nm) of the midpoint between the flexion facet centers (Iwaki et al., JBJS, 2000) under low compression (44 N), 2) AP position of the medial and lateral low points (LP) of the femoral component during a lunge motion (Varadarajan et al., 2008). RESULTS. The TKA-A design demonstrated decreased AP laxity compared to TKA-B and TKA-C at all evaluated flexion angles beyond full extension (Figure 1, A). Both the TKA-A and TKA-B designs demonstrated greater IE laxity than TKA-C in early and mid-flexion (Figure 1, B). Considering lunge kinematics, the TKA-A design experienced the greatest rollback (change in AP position) of both condyles throughout flexion (lateral: 13 mm, medial: 7 mm) compared to TKA-B and TKA-C (lateral: 10 mm, medial: −1 mm; lateral: 9 mm medial: 6 mm), respectively. Rollback of the lateral condyle was greater than that of the medial condyle for all designs, which is consistent with the patterns reported for the intact knee (Hill et al., 2000, Dennis et al., 2005). Furthermore, the rate of rollback was more consistent for TKA-A compared to TKA-B and TKA-C. CONCLUSION. The new tri-condylar TKA design exhibited greater AP stability at all flexion angles and greater IE laxity through mid-flexion compared to two clinically-established TKA designs. In addition, posterior femoral rollback was more continuous for this new design. We attribute these findings to the design of the third condyle and the rotating platform bearing. For any figures or tables, please contact authors directly (see Info & Metrics tab above).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 111 - 111
1 Dec 2013
Kusuma S Goodman Z Sheridan KC Wasielewski R
Full Access

INTRODUCTION:. Recent trends in total hip arthroplasty (THA) have resulted in the use of larger acetabular components to achieve larger femoral head sizes to reduce dislocation, and improve range of motion and stability. Such practices can result in significant acetabular bone loss at the time of index THA, increasing risk of anterior/posterior wall compromise, reducing component coverage, component fixation, ingrowth surface and bone stock for future revision surgery. We report here on the effects of increasing acetabular reaming on component coverage and bone loss in a radiographic CT scan based computer model system. METHODS:. A total of 74 normal cadaveric pelves with nonarthritic hip joints underwent thin slice CT scan followed by upload of these scans into the FDA approved radiographic analysis software. Utilizing this software package, baseline three-dimensional calculations of femoral head size and acetabular size were obtained. The software was used to produce a CT scan based model that would simulate reaming and placement of acetabular components in these pelves that were 125, 133 and 150% the size of the native femoral head. Calculations were made of cross sectional area bone loss from anterior/posterior columns, and loss of component coverage with increasing size. RESULTS:. Use of acetabular components that were 125, 133 and 150% the size of the native femoral head led to a average loss of 23, 27% and 33% loss of cross-sectional acetabular bone and an average 7, 16 and 27% loss of acetabular component coverage. CONCLUSION:. The CT scan/computer based model described here demonstrates that acetabular preparation and use of large components simply to gain larger femoral head size can result in significant bone loss and reduced component coverage. Operating hip surgeons attempting to utilize such large components must take great caution when attempting to maximize acetabular component size


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 66 - 66
1 Dec 2017
Sabesan V Petersen-Fitts GR Lombardo DJ Liou W
Full Access

Manufacturers of reverse shoulder arthroplasty (RSA) implants have recently designed innovative implants to optimise performance in rotator cuff deficient shoulders. These advancements are not without tradeoff and can have negative biomechanical effects. The objective of this study was to develop an integrated FEA kinematic model to compare the muscle forces and joint reaction force (JRF) of 3 different RSA designs. A kinematic model of a normal shoulder joint was adapted from the Delft model and integrated with the OpenSim shoulder model. Static optimisations then allowed for calculation of the individual muscle forces, moment arms and JRF relative to net joint moments. Three dimensional computer models of humeral lateralised design (HLD), glenoid lateral design (GLD), and Grammont design (GD) RSA were integrated and parametric studies were performed. Overall there were decreases in deltoid and rotator cuff muscle forces for all 3 RSA designs. These decreases were greatest in the middle deltoid of the HLD model for abduction and flexion and in the rotator cuff muscles under both internal and external rotation. The joint reactive forces in abduction and flexion decreased similarly for all RSA designs compared to the normal shoulder model, with the greatest decrease seen in the HLD model. These findings demonstrate that the design characteristics implicit in these modified RSA prostheses result in kinematic differences most prominently seen in the deltoid muscle and overall joint reactive forces. Further research utilising this novel integrated model can help guide continued optimisation of RSA design and clinical outcomes


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 56 - 56
1 Apr 2019
Siggelkow E Bandi M Blatter I
Full Access

Introduction. Total-knee-arthroplasty (TKA) is a well-established method to restore the joint function of the human knee. Different types of TKA designs are clinically available which can be divided in two main groups, the posterior-cruciate- ligament (PCL) sacrificing and retaining group. However, pre-operatively it is often difficult to plan for one or the other. Therefore, the research question was: Is it possible to develop a TKA bearing design which works for both the cruciate sacrificing and retaining technique? A medial-congruent (MC) bearing design was developed, characterized by a high medial sagittal conformity and lower lateral sagittal conformity, which can be used for both cruciate ligament states. This study compares the laxity and kinematics of this MC design to a contemporary PS design for the cruciate sacrificing technique and to a contemporary CR design for the cruciate retaining technique. Methods. Four specimen-specific computer models of the human knee, consisting of a femur, tibia and fibula bone as well as the contribution of the ligaments and capsule, were virtually implanted with three TKA designs in four constellations: 1) MC without PCL, 2) MC with PCL, 3) contemporary PS without PCL and 4) contemporary CR with PCL following the design specific surgical technique and tibia slopes. Laxity tests in internal-external rotation (moment ± 4 Nm) were performed with the implanted models for a weight bearing case (500N compression). In addition, a high demanding activity (lunge) was simulated. The resulting averaged laxities and kinematics were analysed and compared to each other. Results. When sacrificing the PCL, MC showed lower medial laxity throughout flexion and higher lateral laxity above 60° flexion compared to the PS design. When retaining the PCL, the MC resulted in lower medial laxity throughout flexion, lower lateral laxity in extension and similar lateral laxity in flexion compared to the CR design. When sacrificing the PCL in the lunge activity, the MC design had a more posterior position throughout flexion on both condyles until deep flexion when the engagement of the cam/spine occurred for the PS design and posterior motion of the medial condyle during mid-flexion as opposed to anterior motion for the PS design. When retaining the PCL in the lunge-activity, the MC design had a more posterior position throughout the activity, and similar medial and lateral condyle motion throughout flexion compared to the CR design. Conclusion. When sacrificing the PCL, MC behaved similar to a contemporary PS design with more medial stability, more lateral laxity in deep flexion, and a posterior position during a lunge activity that did not depend on a cam/spine mechanism. When retaining the PCL, MC behaved similar to a contemporary CR design with more medial stability, similar lateral laxity in deep flexion, and a posterior position during a lunge activity demonstrating that the increased medial conformity did not cause a kinematic conflict with the retained PCL. These findings illustrate the concept that the MC design can be used for both the PCL sacrificing and retaining technique


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 71 - 71
1 Dec 2017
Sabesan V Whaley J Pathak V Zhang L
Full Access

Introduction. Varying degrees of posterior glenoid bone loss occurs in patients with end stage osteoarthritis and can result in increased glenoid retroversion. Ultimately, the goal is to correct retroversion to restore normal biomechanics of the glenohumeral joint. The goal of this study was to identify the optimal augmented glenoid design based on finite element model analysis which will provide key insights into implant loosening mechanisms and stability. Materials and Methods. Two different augmented glenoid designs, posterior wedge and posterior step- were created as a computer model by a computer aided design software (CAD). These implants were virtually implanted to correct 20° glenoid retroversion and the different mechanical parameters were calculated including: the glenohumeral contact pressure, the cement stress, the shear stress, and relative micromotions at the bone cement interface. Results. During abduction, high strain was concentrated around the peg and posterior glenoid bone. Strain was noticeably higher in stepped design (1–2%) than the wedged design (0.4–1.2%). Stepped glenoid models sustained 30% and 70% higher stresses than those experienced by the wedged glenoid implant models at two different corrections. Distractions predicted by the stepped designs were found to be at least twice as much as those by the wedged designs. Similarly, in compression values were 1.5–8 magnitudes higher in stepped designs than those of wedged designs. The wedged design, the amount of micromotion was not affected by the size of the augment (8° and 16°). Discussion. Our study showed that the wedged design experienced less stress compared to stepped design with abduction loading. Notably, the wedged design experienced less stress as the size of the wedge increased to correct a more retroverted arthritic glenoid. The step design also had the highest amount of micromotion which ultimately points to increased failures rate and decreased performace


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 81 - 81
1 Apr 2018
Sabesan V Whaley J Lima D Villa J Pathak V Zhang L
Full Access

Introduction. Varying degrees of posterior glenoid bone loss occurs in patients with end stage osteoarthritis and can result in increased glenoid retroversion. The excessive retroversion can affect implant stability, eccentric glenoid loading, and fixation stresses. Ultimately, the goal is to correct retroversion to restore normal biomechanics of the glenohumeral joint. The objective of this study was to identify the optimal augmented glenoid design based on finite element analysis (FEA) modeling which will provide key insights into implant loosening mechanisms and stability. Materials and Methods. Two different augmented glenoid designs, posterior wedge and posterior step- were created as a computer model by a computer aided design software (CAD). These implant CAD models were created per precise manufacturers dimensions and sizes of the augmented implant designs. These implants were virtually implanted to correct 20° glenoid retroversion and the different mechanical parameters were calculated including: the glenohumeral subluxation force, relative micromotion at the bone-cement interface the glenoid, implant and cement mantle stress levels. The FEA model was then utilized to make measurements while the simulating abduction with the different implant designs. The biomechanical response parameters were compared between the models at comparable retroversion correction. Results. The model prediction of force ratio for the augmented wedge design was 0.56 and for the augmented step design was 0.87. The step design had higher force ratio than the wedge one at similar conformity settings. Micromotion was defined as a combination of three components based on different directions. The distraction measured for the wedge design was 0.05 mm and for the step component, 0.14 mm. Both implants showed a similar pattern translation wise. The greatest difference between the two implants was from the compression standpoint, where the step component showed almost three times more movement than the wedge design implant. Overall, the step design registered greater micromotion than the wedge one during abduction physiologic loading. The level of stress generated during abduction on the glenoid vault was 1.65 MPa for the wedge design and 3.78 MPa for the step one. All stress levels were found below the determined bone failure limit for the bone and polyethylene (10–20 MPa). Concerning implant stress, the results measured on the backside of the wedge and step components were 6.62 MPa and 13.25 MPa, respectively. Both components showed high level of stress level measured on the cement mantle, which exceeded the endurance limit for cement fracture (4 MPa). Discussion. The augmented glenoid is a novel surgical implant for use in with severe glenohumeral osteoarthritis. Unlike standard glenoid prosthetics, the augmented glenoid is better suited for correcting moderate to severe retroversion. Whereas a step design might provide higher glenohumeral stability, the tradeoff is higher glenoid vault, implant and cement mantle stress levels, and micromotion, indicating higher risks of implant loosening, failure or fracture over time, leading to poorer clinical outcomes and higher revision rates


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 9 - 9
1 Jul 2014
Bigliani L
Full Access

Assessing glenoid version is important for a successful total shoulder arthroplasty. Glenoid version is defined as the orientation of the glenoid cavity in relation to a plane perpendicular to the scapula body. Glenoid revision averages between 1 to 2 degrees of retroversion and varies between race and sex. In general glenoid retroversion is overestimated by 6.5 degrees on plain radiographs. Furthermore standard axial 2D CT is aligned to the patient's body and not aligned to the scapula. Therefore 3D reconstructions generated from standard CT allows for analysis of the scapula as a free body and correct version measurements can be made unaffected by positioning. If you add a computer modeling coordinate system in which implants can be added, then computer simulation surgery can be performed. This is important because implanting a glenoid component in excessive retroversion leads to increased stress at the glenoid component and cement mantle and decreased contact with the humeral component. Also excessive reaming of the glenoid surface to neutral retroversion can lead to excessive bone loss and penetration of the glenoid vault by either the pegs or the keel of the glenoid component


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 9 - 9
1 Nov 2015
Sperling J
Full Access

A primary goal of shoulder arthroplasty is to place the components in anatomic version. However, traditional instrumentation does not accommodate glenoid wear patterns. Therefore, many investigators have attempted to use computer modeling or CT-based algorithms to create custom targeting guides to achieve this goal. There are some recent studies investigating the use of custom guides. Iannotti et al. published in JBJS-American in 2012 on the use of patient specific instrumentation. There were 31 patients included in the study. The authors found that the planning software and patient specific instrumentation were helpful overall, but particularly of benefit in patients with retroversion in excess of 16 degrees. In this group of patients, the mean deviation was 10 degrees in the standard surgical group and 1.2 degrees in the patient specific instrumentation group. Throckmorton presented a study at the AAOS in 2014 on 70 cadaveric shoulders. There was one high volume surgeon (>100 shoulder arthroplasties a year), two middle volume surgeons (20–50 shoulder arthroplasties a year), and two low volume surgeons (less than 20 shoulder arthroplasties per year). Overall, the custom guide was significantly more accurate than standard instrumentation. The custom guides were found to be especially more accurate among specimens with associated glenoid wear. There were no strong trends to indicate consistent differences between high, medium, and low volume surgeons. The authors concluded that custom guides have narrower standard deviation and fewer significant errors than standard instrumentation. Custom guides continue to evolve for use in shoulder arthroplasty including some guides that allow the surgeon to decide intra-operatively between anatomic shoulder arthroplasty and reverse arthroplasty. Additional studies will be necessary to further define the role of patient specific instrumentation in practice


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 8 - 8
1 Nov 2016
Griffiths M Langohr G Athwal G Johnson J
Full Access

There are a variety of sizes currently available for reverse total shoulder arthroplasty (RTSA) implant systems. Common sizing options include a smaller 36 to 38 mm or a larger 40 to 42 mm glenosphere, and are typically selected based on surgeon preference or patient size. Previous studies have only evaluated the abduction and adduction range of motion within a single plane of elevation, providing a limited view of the joint's possible range of motion. The purpose of this study was to use computer modeling to evaluate the abduction and adduction range of motion across multiple planes of elevation for a range of glenosphere sizes. Computed tomography images of four cadaveric specimens (age: 54 ± 24 years) were used to obtain the osseous anatomy to be utilised in the model. Solid-body motion studies of the RTSA models were constructed with varying glenosphere diameters of 33, 36, 39, 42, and 45 mm in Solidworks (Dassault Systems, US). The implant components were scaled, while maintaining a consistent centre of rotation. Simulations encompassing the full range of abduction and adduction were conducted for the planes of elevation between −15˚ and 135˚ at 15˚ intervals, with the motion of the humerus being constrained in neutral internal-external rotation throughout all planes. Angles of elevation were obtained utilising the humeral long axis and the RTSA centre of rotation. Statistical analysis was performed using repeated measures ANOVA. Glenosphere diameter was found to significantly affect the adduction range of motion (p=0.043), in which the largest size provided approximately 17˚ more adduction range of motion than the smallest. However, abduction range of motion was not found to be significantly affected through the alteration of glenosphere size (p=0.449). The plane of elevation was not found to significantly affect abduction or abduction (p=0.585 & p=0.225, respectively). Increasing glenosphere diameter resulted in an increased adduction range of motion when averaged across the tested planes of elevation; however the observed influence on abduction was not significant. These are similar to the trends observed in the previous single plane of elevation studies. These findings illustrate the importance of implant sizing related to range of motion. Further studies are required to determine the influence of glenosphere size on internal and external range of motion


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 138 - 138
1 May 2016
Frame M
Full Access

Aim. The aim of this study is to outline the steps and techniques required to create a patient specific 3D printed guide for the accurate placement of the origin of the femoral tunnel for single bundle ACL reconstruction. Introduction. Placements of the femoral tunnels for ACL reconstruction have changed over the years 1,2. Most recently there has been a trend towards placing the tunnels in a more anatomic position. There has been subsequent debate as to where this anatomic position should be 3. The problem with any attempt at consensus over the placement of an anatomic landmark is that each patient has some variation in their positioning and therefore a fixed point for all has compromise for all, as it is an average 4. Our aim was to attempt to make a cost effective and quick custom guide that could allow placement of the center of the patients’ newly created femoral tunnel in the mid position of their contralateral native ACL femoral footprint. Materials & Methods. We took a standard protocol MRI scan of a patient's knee without ACL injury transferred the DICOM files to a personal computer running OsiriX (Pixmeo, Geneva, Switzerland.) and analyzed it for a series of specific anatomical landmarks (fig1). These measurements and points were then utilized to create a 3D computer aided design (CAD) model of a custom guide. This was done using the 3D CAD program 123Design (Autodesk Ltd., Farnbourgh, Hampshire). This 3D model was then uploaded to an online 3D printing service and the physical guide was created in transparent acrylic based photopolymer, PA220 plastic (fig 2) and 316L stainless steel. The models created were then measured using vernier calipers to confirm the accuracy of the final guides. The models produced were accurate with no statistical difference in size and positioning of the center of the ACL footprint from the original computer model and to the position of the ACL from the MRI scans. The costs for the models 3D printed were £3.50 for the PA220 plastic, £15 for the transparent photopolymer and £25 for the 316L stainless steel. The time taken from MRI to delivery for the physical models was 7 days. Conclusion. This study serves as the first step and a proof of concept for the accurate creation of patient specific 3D printed guides for the anatomical placement of the femoral tunnel for ACL reconstruction. The guides were easy to create and produce taking only a week and with a cost of between £3.50 and £25


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 64 - 64
1 Jun 2012
Fetto J
Full Access

Non-cemented components have traditionally employed several possible features, among them a stem and/or collar, to achieve proper alignment and initial implant stability within the proximal femoral cavity. The advent of MIS has stimulated an interest in reducing the dimensions of implants, specifically stem length, in order to facilitate introduction and implantation of the component. The consequence of this trend appears to be an increase in early aseptic failure, of some components, due to loosening and migration. Several important questions have arisen. What are the direction of the deforming forces about a hip during daily activities?. What design features should a short stem implant exhibit so as to provide optimum stability against these forces?. Is having a stem an absolute requirement of a femoral component?. What is the minimum “safe” length a stem must have?. How can proper short stem alignment be optimized? Is intra-operative x-ray exposure necessary?. This presentation will discuss the computer modeling, laboratory testing and clinical outcomes of various. component designs; and make suggestions concerning directions for future investigations


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 115 - 115
1 Mar 2017
Riviere C Shah H Howell S Aframian A Iranpour F Auvinet E Cobb J Harris S
Full Access

BACKGROUND. Trochlear geometry of modern femoral implants is designed for the mechanical alignment (MA) technique for Total Knee Arthroplasty (TKA). The biomechanical goal is to create a proximalised and more valgus trochlea to better capture the patella and optimize tracking. In contrast, Kinematic alignment (KA) technique for TKA respects the integrity of the soft tissue envelope and therefore aims to restore native articular surfaces, either femoro-tibial or femoro-patellar. Consequently, it is possible that current implant designs are not suitable for restoring patient specific trochlea anatomy when they are implanted using the kinematic technique. This could cause patellar complications, either anterior knee pain, instability or accelerated wear or loosening. The aim of our study is therefore to explore the extent to which native trochlear geometry is restored when the Persona. ®. implant (Zimmer, Warsaw, USA) is kinematically aligned. METHODS. A retrospective study of a cohort of 15 patients with KA-TKA was performed with the Persona. ®. prosthesis (Zimmer, Warsaw, USA). Preoperative knee MRIs and postoperative knee CTs were segmented to create 3D femoral models. MRI and CT segmentation used Materialise Mimics® and Acrobot Modeller® software, respectively. Persona. ®. implants were laser-scanned to generate 3D implant models. Those implant models have been overlaid on the 3D femoral implant model (generated via segmentation of postoperative CTs) to replicate, in silico, the alignment of the implant on the post-operative bone and to reproduce in the computer models the features of the implant lost due to CT metal artefacts. 3D models generated from post-operative CT and pre-operative MRI were registered to the same coordinate geometry. A custom written planner was used to align the implant, as located on the CT, onto the pre-operative MRI based model (figure 1). In house software enabled a comparison of trochlea parameters between the native trochlea and the performed prosthetic trochlea (figure 2). Parameters assessed included 3D trochlear axis and anteroposterior offset from medial facet, central groove, and lateral facet. Sulcus angle at 30% and 40% flexion was also measured. Inter and intra observer measurement variabilities have been assessed. RESULTS. Varus-valgus rotation between the native and prosthetic trochleae was significantly different (p<0.001), with the prosthetic trochlear groove being on average 7.9 degrees more valgus. Medial and lateral facets and trochlear groove were significantly understuffed (3 to 6mm) postoperatively in the proximal two thirds of the trochlear, with greatest understuffing for the lateral facet (p<0.05). The mean medio-lateral translation and internal-external rotation of the groove and the sulcus angle showed no statistical differences, pre and postoperatively (figure 3). CONCLUSION. Kinematic alignment of Persona. ®. implants poorly restores native trochlear geometry. The clinical impact of this finding remains to be defined. For figures/tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 16 - 16
1 Mar 2017
Twiggs J Miles B McMahon S Bare J Solomon M Hogan J Roberts B Theodore W
Full Access

Introduction. Both navigation and instrumented bone referencing use unreliable intraoperative landmark identification or fixed referencing rules which don't reflect patient specific variability. PSI, however, lacks the flexibility to adapt to soft tissue factors not known during preoperative planning, in addition to suffering error from guide fit. A novel method of recreating surgical cut planes that combines preoperative image based identification of landmarks and planning with intraoperative adjustability is under development. This method uses an intraoperative 3D scan of the bone in conjunction with a preoperative CT scan to achieve the desired cuts and so avoids issues of intraoperative identification of landmarks. Method. During TKA surgery, a reference device is placed on the exposed femur. The device is used to position a target block which is pinned to the bone (see Figure 1). The condyles and target block are then scanned, the process taking a second to complete. This 3D scan is filtered to remove extraneous bodies and noise leaving only the bony geometry and target block (see Figure 2). The scan is then reconciled to the known bone geometry taken from preoperative CT scans. A cutting block is then fixed to the target block with a reference array visible to the camera attached. Pre-planned cut planes on a computer model of the bone are compared to the position and configuration of the distal cutting guide. Software guides the surgeon in real-time on the necessary configuration changes required to align the cutting block. The cut is performed on the distal femur, the cutting guide removed from the target-block, and a second scan performed. The software repeats the filtering and alignment processes and provides the surgeon with data on how closely the performed cut matches the alignment planned. Results. Two patients underwent this method alongside traditional alignment techniques. The initial 3D scan of the distal femoral condyles of the patients was matched to their corresponding CT scans. The first case had a mean error of 0.65 mm with 85% of errors falling below a magnitude of 1.16 mm and 58% falling below the case mean (see Figure 3). The second case had a mean error of 0.39 mm with 84% of errors falling below 0.70 mm and 60% falling below the case mean. It should be noted that the error introduced was due to the omission of soft tissue such as the PCL in the CT scan. Exposed bone portions of the scan geometry matched well with the CT scan, with error magnitudes significantly below the mean. Discussion. The ability to obtain useful surgical alignment using preoperatively identified landmarks, alongside the small space requirements of a modern 3D scanner is sharply contrasted against the large space requirements and need for intraoperative probing of traditional navigation systems. Likewise, the use of preoperative planning and landmark identification to overcome intraoperative data capture variability mirrors that of PSI, but allows for potentially much greater accuracy of execution as the issue of guide fit and topology variation is avoided while intraoperative flexibility is maintained