Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 7 - 7
1 Jun 2023
Harris PC Lacey S Steward A Sertori M Homan J
Full Access

Introduction. The various problems that are managed with circular external fixation (e.g. deformity, complex fractures) also typically require serial plain x-ray imaging. One of the challenges here is that the relatively radio-opaque components of the circular external fixator (e.g. the rings) can obscure the view of the area of interest (e.g. osteotomy site, fracture site). In this presentation we describe how the geometry of the x-ray beam affects the produced image and how we can use knowledge of this to our advantage. Whilst this can be applied to any long bone, we have focused on the tibia, given that it's the most common long bone that is treated by circular external fixation. Materials & Methods. In the first part of the presentation we describe the known attributes (geometry) of the x-ray beam and postulate what effect it would have when we x-ray a long bone that is surrounded by a circular external fixator. In the second part we demonstrate this in practice using a tibia and a 3 ring circular external fixator. Differing x-ray beam orientations are used to demonstrate both how the geometry of the beam affects the produced image and how we can use this to our advantage to better visualise part of the bone. Results. The practical part of the study confirmed the theoretical part. Conclusions. Knowledge of the beam geometry can be used to minimise the obscuring nature of the circular fixator. This technique is simple and can be easily taught to the radiographer. It is a useful adjunct for the limb reconstruction surgeon


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 12 - 12
1 Sep 2014
Ferreira N Marais L
Full Access

Purpose of study. Pin tract infection is a common complication with the use of circular external fixators. HIV infection itself is frequently quoted as a relative contra-indication for the use of circular external fixators for complex trauma and limb reconstruction in HIV seropositive individuals. Methods. Between July 2008 and December 2012, 286 patients were treated with circular external fixators at our tertiary level government hospital. A retrospective review was undertaken to compare the rate and severity of pin tract sepsis in HIV seropositive and seronegative patients. Results. Two-hundred and twenty-three patients met the inclusion and exclusion criteria. Pin tract sepsis was found in 51 patients overall (22.8%). The incidences of pin tract sepsis in the seropositive group, seronegative group, and the unknown group are 22.5%, 22.8% and 23.8% respectively, and the differences were not statistically significant. The severity of pin tract sepsis in the individual groups was also similar. Conclusion. Pin tract sepsis is a common complication with the use of circular external fixators. The incidence and severity of pin tract infection is not influenced by HIV infection, and should not in itself deter from the use of circular external fixators for complex trauma and limb reconstruction in HIV seropositive individuals. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 39 - 39
1 Mar 2010
Vitale MG Marangoz S Gomez JA van Bosse HJP Hyman JE Feldman DS Sala DA Stein M
Full Access

Purpose: Use of six-axis analysis and computer assisted deformity correction via a circular external fixator is a new method for deformity correction. We investigated its accuracy and safety in reconstruction of femoral deformity in children and young adults. Method: We retrospectively reviewed all cases including the indications for use and the methodology of application of the computer assisted six-axis analysis and circular external fixator for reconstruction of 22 femora in 20 patients. Twelve patients were female, and 8 were male. The average age was 13.9 (range, 5.9–24.6). Etiology included traumatic (7), idiopathic (6), multiple enchondromatosis (2), rickets (2), congenital femoral deficiency (2), spondyloepiphyseal dysplasia (1), congenital pseudohypoparathyroidisim (1), and multifocal osteomyelitis (1). Clinical and radiographic data were analyzed. Results: Average follow-up was 14.4 months (range, 4.5–32). Average time in frame was 6.2 months (range, 2.6–19). Bone lengthening of 3.9 cm (range, 1–8.5) was performed in 12 femora. In genu valgum patients, the mLDFA improved from a mean of 73.7° to a mean of 89°. In genu varum patients, the mLDFA improved from a mean of 99.8° to a mean of 89.5°. Complications included pin tract infection in 6, knee stiffness in 3, delayed union in 2, skin irritation in 1, posterior knee subluxation in 2, both of which had stable knees preoperatively. One patient was lost to follow-up and returned back with deformity. No complications occurred in 8 patients. Conclusion: Computer assisted femoral deformity correction with six-axis analysis and application of circular external fixator is a useful technique with the advantage of managing multiplanar deformities in children and young adults. It has the potential complications of the use of any external fixator. Close follow-up is necessary to avoid subluxation of the knee joint even in patients with stable knees. Accurate and safe correction can be achieved in almost all patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 3 - 3
1 Jun 2023
Williams L Stamps G Peak H Singh S Narayan B Graham S Peterson N
Full Access

Introduction

External fixation (EF) devices are commonly used in the management of complex skeletal trauma, as well as in elective limb reconstruction surgery for the management of congenital and acquired pathology. The subsequent removal of an EF is commonly performed under a general anaesthetic in an operating theatre. This practice is resource intensive and limits the amount of operating theatre time available for other surgical cases. We aimed to assess the use of regional anaesthesia as an alternative method of analgesia to facilitate EF removal in an outpatient setting.

Materials & Methods

This prospective case series evaluated the first 20 consecutive cases of EF removal in the outpatient clinic between 10/06/22 to 16/09/22. Regional anaesthesia using ultrasound-guided blockade of peripheral nerves was administered using 1% lidocaine due to its rapid onset and short half-life. Patients were assessed for additional analgesia requirement, asked to evaluate their experience and perceived pain using the Visual Analogue Scale (VAS).


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 159 - 159
1 Feb 2004
Zaharakis N Nteros I Papailiou A Theodorakopoulos P Solomos P Hatzistamatiou K Anastopoulos G
Full Access

Aim: Complex tibial plateau fractures, Shatzker type VI, rare in the past, became more common nowadays because of high energy injuries. These complex fractures usually accompanied by compromised skin and soft tissue envelope requires deliberate planning as treatment in the past invite a high rate of complications. Materials and method: During a period of 24 months, 16 fractures of tibial plateau, Shatzker VI, were treated in 16 patients, all regarding vehicle accidents.11 patients were men and 5 women with a mean age of 42 years old (27–67).There were 2 open and 14 closed fractures (3 type I, 8 type II and 3 type III according to Tscherne’s classification).All cases were treated with circular external fixators (hybrid), whereas 9 of them needed additional mini internal fixation (one or two screws). Results: 14 patients were evaluated with a mean period of follow up 1.9 years. Healing was achieved in all 14 cases with a mean period of 16 weeks (12–24).Fixator removal was performed when bone healing was completed. There was no deep infection. 12 patients at the end of treatment had a range of motion between 0° – 120°. 3 fractures developed a malunion (1 valgus deformity, 2 anterior angular deformity). Radiographic evidence of arthritis appeared in 2 patients during follow up. Pin tract infection occurred in one case, treated with antibiotics. Conclusion: The use of circular external fixators (three olive wires to tibial plateau) obtains good stabilization while allows early joint motion, protects soft tissue envelope and in combination with minimal internal fixation achieves satisfactory reduction of comminuted fractures making the technique promising for the management of these complex fractures


The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1417 - 1422
1 Oct 2015
Ferreira N Marais LC Aldous C

Tibial nonunion represents a spectrum of conditions which are challenging to treat, and optimal management remains unclear despite its high rate of incidence. We present 44 consecutive patients with 46 stiff tibial nonunions, treated with hexapod external fixators and distraction to achieve union and gradual deformity correction. There were 31 men and 13 women with a mean age of 35 years (18 to 68) and a mean follow-up of 12 months (6 to 40). No tibial osteotomies or bone graft procedures were performed. Bony union was achieved after the initial surgery in 41 (89.1%) tibias. Four persistent nonunions united after repeat treatment with closed hexapod distraction, resulting in bony union in 45 (97.8%) patients. The mean time to union was 23 weeks (11 to 49). Leg-length was restored to within 1 cm of the contralateral side in all tibias. Mechanical alignment was restored to within 5° of normal in 42 (91.3%) tibias. Closed distraction of stiff tibial nonunions can predictably lead to union without further surgery or bone graft. In addition to generating the required distraction to achieve union, hexapod circular external fixators can accurately correct concurrent deformities and limb-length discrepancies.

Cite this article: Bone Joint J 2015;97-B:1417–22.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 8 - 8
1 Jun 2023
Harris PC Lacey S Perdomo A Ramsay G
Full Access

Introduction. The vast majority of orthopaedic surgeons use C-arm fluoroscopy in the operating theatre when building a circular external fixator. In the absence of previous research in this area, we hypothesised that the surgeon who builds a circular external fixator is exposed to a greater amount of radiation purely as a result of the presence of the metallic fixator in the x-ray beam. The aim of our study therefore was to investigate how the presence of a circular external fixator affects the radiation dose to the surgeon and the surgical assistant. Materials & Methods. A simulated environment was created using a radiolucent operating table, an acrylic lower limb phantom (below knee segment), various configurations of metalic circular external fixation, and a standard size C-arm image intensifier. The variables investigated were 1. the amount of metal in the beam 2. the orientation of the beam (PA vertical vs lateral) 3. the horizonal distance of the person from the beam (surgeon vs assistant) and 4. the vertical distance of the various body parts from the beam (e.g. thyroid, groin). In terms of radiation dose, we recorded two things : 1. the dose produced by the image intensifier 2. the dose rate at standardised positions in the operating theatre. The latter was done using a solid-state survey sensor. These positions represented both where the surgeon and surgical assistant typically stand plus the heights of their various body regions relative to the operating table. Results. The effect of the presence of the circular external fixator : all frame constructs tested resulted in a statistically significant greater radiation dose both produced by the image intensifier and received by the surgical team. The effect of the beam orientation : the PA (vertical) orientation resulted in a statistically significant greater radiation dose for the surgeon than did the lateral orientation, but made no difference for the assistant. The effect of horizontal distance from the beam : unsurprisingly, the surgeon (who was closer to the beam) received a statistically significant greater radiation dose than the assistant. The effect of vertical distance from the beam : for the surgeon, the dose received was highest at the level of the phantom leg / frame, whilst for the assistant there was no statistically significant difference for any level. Conclusions. To our knowledge, this is the first study investigating the radiation dose rate to the orthopaedic surgeon when building a circular external fixator. We found that the surgeon does indeed receive a ‘double whammy’ because the image intensifier puts out a greater amount of radiation plus the metalic frame scatters more of the x-ray beam. Whilst the amounts are relatively small, we think that it's important to quantify doses that orthopaedic surgeons receive to ensure optimal radiation practices


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1248 - 1255
1 Sep 2020
Laufer A Frommer A Gosheger G Roedl R Broeking JN Toporowski G Rachbauer AM Vogt B

Aims. The treatment of tibial aplasia is controversial. Amputation represents the gold standard with good functional results, but is frequently refused by the families. In these patients, treatment with reconstructive limb salvage can be considered. Due to the complexity of the deformity, this remains challenging and should be staged. The present study evaluated the role of femoro-pedal distraction using a circular external fixator in reconstructive treatment of tibial aplasia. The purpose of femoro-pedal distraction is to realign the limb and achieve soft tissue lengthening to allow subsequent reconstructive surgery. Methods. This was a retrospective study involving ten patients (12 limbs) with tibial aplasia, who underwent staged reconstruction. During the first operation a circular hexapod external fixator was applied and femoro-pedal distraction was undertaken over several months. Subsequent surgery included reconstruction of the knee joint and alignment of the foot. Results. The mean follow-up was 7.1 years (2 to 10). The mean age of the patients at the time of the application of the fixator was 2.3 years (1.1 to 5.0). The mean time under distraction was 139.7 days (81.0 to 177.0). A mean fibular distalization of 38.7 mm (14.0 to 67.0) was achieved. Pin infections occurred in four limbs (33.3%) and osteitis in one. A femoral fracture occurred in one patient. Premature removal of the frame was not required in any patient. Sufficient realignment of the leg as well as soft tissue lengthening was achieved in all patients, allowing subsequent reconstruction. All patients were able to mobilize fully weight bearing after reconstruction. Functional outcome was limited in all limbs, and five patients (50.0%) required additional reconstructive operations. Conclusion. Regarding the functional results in the treatment of tibial aplasia, amputation remains superior to limb salvage. The latter procedure should only be performed in patients whose parents refuse amputation. Femoro-pedal distraction efficiently prepares the limb by realigning the leg and soft tissue lengthening. Minor complications are frequent, but usually do not hinder the continuation of distraction. Even though a fully weight-bearing limb is achieved, the functional outcome of reconstructive treatment remains limited. Recurrent deformities frequently occur and may require further operations. Cite this article: Bone Joint J 2020;102-B(9):1248–1255


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 49 - 49
1 Jun 2023
Thompson E Shamoon S Qureshi A
Full Access

Introduction. Circular external fixators are fundamental to lower limb reconstruction, primarily in situations with a high risk of infection such as open fractures. During the Covid-19 pandemic, use of circular frames in our unit decreased, following departmental approval, due to resource management and in keeping with BOA guidelines as we opted to “consider alternative techniques for patients who require soft tissue reconstruction to avoid multiple operations”. These alternatives included the use of internal fixation (plate osteosynthesis and intramedullary nailing) as a measure to reduce the number of hospital attendances for patients and to conserve resources. This change in practice has continued in part following the pandemic with the increased use of internal fixation in cases previously deemed unsuitable for such techniques. We present our experience of this treatment strategy in the management of complex lower limb injuries, focusing on outcomes and consider the lessons learnt. Materials & Methods. Data of patients with complex lower limb injuries treated before, during and after the pandemic were collected from our in-house trauma database, theatre records and follow up clinics. The rationale for choosing other techniques over a circular frame, the type of alternative technique used, the cost of such alternatives, the need for soft tissue reconstruction, time to recovery, complications and amputation rates were compared among groups. Results. These data suggest comparable outcomes between circular frames and alternative techniques can be achieved. A notable reduction in the number of circular frames applied during the review period was observed. Furthermore, frame fixation was associated with more frequent outpatient review and the associated implications for resource management. Conclusions. Conclusion: The Covid-19 pandemic has posed great challenges to the Trauma and Orthopaedic community, forcing us to be flexible by adopting alternative treatment methods to traditional circular external fixation. These alternatives have proven feasible and potentially more cost effective, prompting their adoption in the post pandemic era. However, this change of practice is not without potential consequences and continued investigation is warranted


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 146 - 152
1 Jan 2010
Bilen FE Kocaoglu M Eralp L Balci HI

We report the results of using a combination of fixator-assisted nailing with lengthening over an intramedullary nail in patients with tibial deformity and shortening. Between 1997 and 2007, 13 tibiae in nine patients with a mean age of 25.4 years (17 to 34) were treated with a unilateral external fixator for acute correction of deformity, followed by lengthening over an intramedullary nail with a circular external fixator applied at the same operating session. At the end of the distraction period locking screws were inserted through the intramedullary nail and the external fixator was removed. The mean amount of lengthening was 5.9 cm (2 to 8). The mean time of external fixation was 90 days (38 to 265). The mean external fixation index was 15.8 days/cm (8.9 to 33.1) and the mean bone healing index was 38 days/cm (30 to 60). One patient developed an equinus deformity which responded to stretching and bracing. Another developed a drop foot due to a compartment syndrome, which was treated by fasciotomy. It recovered in three months. Two patients required bone grafting for poor callus formation. We conclude that the combination of fixator-assisted nailing with lengthening over an intramedullary nail can reduce the overall external fixation time and prevent fractures and deformity of the regenerated bone


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 50 - 50
1 Apr 2022
Ferreira N Arkell C Fortuin F Saini A
Full Access

Introduction. The accuracy of hexapod circular external fixator deformity correction is contingent on the precision of radiographic analysis during the planning stage. The aim of this study was to compare the SMART TSF (Smith and Nephew, Memphis, Tennessee) in-suite radiographic analysis methods with the traditional manual deformity analysis methods in terms of accuracy of correction. Materials and Methods. Sawbones models were used to simulate two commonly encountered clinical scenarios. Traditional manual radiographic analysis and digital SMART TSF analysis methods were used to correct the simulated deformities. Results. The final outcomes of all six analysis methods across both simulated scenarios were satisfactory. Any differences in residual deformity between the analysis methods are unlikely to be clinically relevant. All three SMART TSF digital analyses were faster to complete than manual radiographic analyses. Conclusions. With experience and a good understanding of the software, manual radiographic analysis can be extremely accurate and remains the gold standard for deformity analysis. In-suite SMART TSF radiographic analysis is fast and accurate to within clinically relevant parameters. Surgeons can with confidence trust the SMART TSF software to provide analysis and corrections that are clinically acceptable


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 353 - 353
1 May 2010
Kayali C Agus H Eren A Ozluk S
Full Access

Background: In this retrospective study our purpose was to compare two treatment alternatives clinically. Methods: Forty-five patients having grade I or II open tibia fractures were consisted in this study. Twenty-five of them, treated via minimal invasive plate osteosynthesis (MIPO), comprised group I. The latter 20 cases, treated via partial reamed intramedullary nailing (PR-IMN), called as group II. Aggressive debridement of all necrotic soft tissue and bone was performed primarily for all cases in the emergency room at admission to hospital. Definitive fixation was performed on average 3rd days (0 – 5) for group I and 2.5th days (0 – 4) for group II. Clinical evaluation was made on the basis of modified Ketenjian’s criteria. Results: There were no significant differences between groups for demographic data (age, gender) and fracture type (p> 0.05). Full weight bearing periods of the group I and II were 21 and 22.4 weeks respectively. Non-union in one case of group I was revised by using circular external fixator. In another case implant removal was performed due to chronic osteomyelitis. Mal-union was detected in another case. In group II, two cases needed implant revision with intramedullary nail in one and circular external fixator in another for non-union. Mal-union in one case and chronic osteomyelitis in another were late complications of group II. At the last follow up satisfaction rates were as; 21/25 in group I and 18/20 in group II clinically. There was no significant difference between both groups with regard to clinical evaluation (p> 0.05). Conclusion: The clinical results of both groups were similar to each other. Although intramedullary nailing is the first choice, MIPO can be an alternative method for open tibia fractures


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 29 - 29
1 Dec 2022
Pedrini F Salmaso L Mori F Sassu P Innocenti M
Full Access

Open limb fractures are typically due to a high energy trauma. Several recent studied have showed treatment's superiority when a multidisciplinary approach is applied. World Health Organization reports that isolate limb traumas have an incidence rate of 11.5/100.000, causing high costs in terms of hospitalization and patient disability. A lack of experience in soft tissue management in orthopaedics and traumatology seems to be the determining factor in the clinical worsening of complex cases. The therapeutic possibilities offered by microsurgery currently permit simultaneous reconstruction of multiple tissues including vessels and nerves, reducing the rate of amputations, recovery time and preventing postoperative complications. Several scoring systems to assess complex limb traumas exist, among them: NISSSA, MESS, AO and Gustilo Anderson. In 2010, a further scoring system was introduced to focus open fractures of all locations: OTA-OFC. Rather than using a single composite score, the OTA-OFC comprises five components grades (skin, arterial, muscle, bone loss and contamination), each rated from mild to severe. The International Consensus Meeting of 2018 on musculoskeletal infections in orthopaedic surgery identified the OTA-OFC score as an efficient catalogue system with interobserver agreement that is comparable or superior to the Gustilo-Anderson classification. OTA-OFC predicts outcomes such as the need for adjuvant treatments or the likelihood of early amputation. An orthoplastic approach reconstruction must pay adequate attention to bone and soft tissue infections management. Concerning bone management: there is little to no difference in terms of infection rates for Gustilo-Anderson types I–II treated by reamed intramedullary nail, circular external fixator, or unreamed intramedullary nail. In Gustilo-Anderson IIIA-B fractures, circular external fixation appears to provide the lowest infection rates when compared to all other fixation methods. Different technique can be used for the reconstruction of bone and soft tissue defects based on each clinical scenario. Open fracture management with fasciocutaneous or muscle flaps shows comparable outcomes in terms of bone healing, soft tissue coverage, acute infection and chronic osteomyelitis prevention. The type of flap should be tailored based on the type of the defect, bone or soft tissue, location, extension and depth of the defect, size of the osseous gap, fracture type, and orthopaedic implantation. Local flaps should be considered in low energy trauma, when skin and soft tissue is not traumatized. In high energy fractures with bone exposure, muscle flaps may offer a more reliable reconstruction with fewer flap failures and lower reoperation rates. On exposed fractures several studies report precise timing for a proper reconstruction. Hence, timing of soft tissue coverage is a critical for length of in-hospital stay and most of the early postoperative complications and outcomes. Early coverage has been associated with higher union rates and lower complications and infection rates compared to those reconstructed after 5-7 days. Furthermore, early reconstruction improves flap survival and reduces surgical complexity, as microsurgical free flap procedures become more challenging with a delay due to an increased pro-thrombotic environment, tissue edema and the increasingly friable vessels. Only those patients presenting to facilities with an actual dedicated orthoplastic trauma service are likely to receive definitive treatment of a severe open fracture with tissue loss within the established parameters of good practice. We conclude that the surgeon's experience appears to be the decisive element in the orthoplastic approach, although reconstructive algorithms may assist in decisional and planification of surgery


The Bone & Joint Journal
Vol. 97-B, Issue 12 | Pages 1628 - 1633
1 Dec 2015
Elmadag M Uzer G Yildiz F Erden T Bilsel K Büyükpinarbasili N Üsümez A Bozdag E Sen C

This animal study compares different methods of performing an osteotomy, including using an Erbium-doped Yttrium Aluminum Garnet laser, histologically, radiologically and biomechanically. A total of 24 New Zealand rabbits were divided into four groups (Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical saw blade and Group IV: laser). A proximal transverse diaphyseal osteotomy was performed on the right tibias of the rabbits after the application of a circular external fixator. The rabbits were killed six weeks after the procedure, the operated tibias were resected and radiographs taken. . The specimens were tested biomechanically using three-point bending forces, and four tibias from each group were examined histologically. Outcome parameters were the biomechanical stability of the tibias as assessed by the failure to load and radiographic and histological examination of the osteotomy site. . The osteotomies healed in all specimens both radiographically and histologically. The differences in the mean radiographic (p = 0.568) and histological (p = 0.71) scores, and in the mean failure loads (p = 0.180) were not statistically significant between the groups. . Different methods of performing an osteotomy give similar quality of union. The laser osteotomy, which is not widely used in orthopaedics is an alternative to the current methods. Cite this article: Bone Joint J 2015;97-B:1628–33


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 44 - 44
1 May 2021
Zenios M Oyadiji T Zamini-Farahani A
Full Access

Introduction. In my paediatric Orthopaedic practice I use Kirchner wires for the fixation of the TSF on bone. I noted a significant percentage of wire loosening during the post-operative period. The aim of this project was to establish the effectiveness of the wire clamping mechanism and find ways to reduce the incidence of wire loosening when using the TSF. Materials and Methods. In the first instance wire slippage was measured intra-operatively after the tensioner was removed using an intra-operative professional camera. Following this study mechanical tests were performed in the lab measuring the pull out properties of Kirchner wires using different bolts and different torque levels in order to tighten the wire on the fixator. Results. Our clinical study confirmed wire slippage intra-operatively immediately after the tensioner was removed. Wire slippage after the tensioner was removed was found to vary from 0.01 mm to 0.51 mm (mean 0.19 mm). Our mechanical tests showed that the ideal torque for tightening the wire on the frame using a bolt was around 15 N.m. A comparison between cannulated and slotted bolts suggested that cannulated bolts are more effective as a clamping mechanism. A comparison between aluminium made Taylor Spatial frame rings and stainless steel made Ilizarov rings suggested that the Taylor Spatial frame rings are more effective as part of a clamping mechanism. Conclusions. It is important that clinicians routinely measure the torque they use to clamp wires on circular external fixators. Clinicians and manufacturers are informed that the type of bolt used is important in maintaining wire tension. Manufacturers should design the ideal bolt which effectively grips the wire without the risk of fracture. The Ilizarov frame clamping mechanism can be effectively used with the Taylor Spatial frame


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 288 - 288
1 May 2010
Erdem M Sen C Eralp L Ozden V Kocaoglu M
Full Access

Background: The occurrence of congenitally short metatarsals is associated with an abnormal gait and an aesthetically displeasing appearance. Similarly, short metacarpals result in severe cosmetic disfigurement, particularly in young female patients. Methods: We examined and performed bone lengthening surgery in 13 female and 2 male patients. Of these, procedures were conducted on 12 metatarsals of 8 patients, 4 metacarpals and 1 metatarsal of a single patient, 1 metacarpal and 1 metatarsal of a single patient and 7 metacarpals of 5 patients. The mean age of the patients who underwent metacarpal procedures was 14.5 (10–21) years while the mean age of those who underwent metatarsal procedures was 17.5 (10–25) years. The callotasis method was employed for these procedures and we used either a unilateral external fixator and/or a circular external fixator. Results: The mean healing index and increase in metacarpal length was 1.6 (1.1–2.3) months/cm and 17.6 (13–26) mm, respectively. The mean follow-up period for patients who underwent metacarpal lengthening was 57.5 (12–96) months. The mean healing index and increase in metatarsal length was 1.6 (1.0–2.0) months/cm and 24.3 (20–30) mm respectively. The mean follow-up period for patients who underwent metatarsal lengthening was 48.3 (12–72) months. The preoperative AOFAS (American Orthopaedic Foot and Ankle Society) scores were good in 5 and excellent in 9 cases. The functional scores of metatarso-phalangial (MTP) joint of lengthened metatarsals for the lesser toe were excellent in 12 and good in 2 cases based on the AOFAS scoring system. All patients who underwent metacarpal lengthening reported that they were satisfied and could conduct their daily activities with good functional and aesthetic results. Complications included 4 angulations, 1 subluxation and 1 non-union and were seen in 6 of the metatarsal lengthening cases that exceeded 40% (or > 20 mm) of the total length of the original bone. Interpretation: There are recommendations in the literature that allow for the avoidance of severe complications and for the shortening of the consolidation period. We conclude that the periosteum must be protected with percutaneus osteotomy and lengthening should be performed at a rate of 0.25 mm twice a day, should not exceeding 40% of the original bone length (or > 20 mm). If the anticipated lengthening exceeds these predefined values then we suggest that the procedure should be performed using a circular external fixator with temporary fixation of the MCP or the MTP joint and the inclusion of the proximal phalanx in the frame


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 989 - 993
1 Jul 2012
Monsell FP Howells NR Lawniczak D Jeffcote B Mitchell SR

Between 2005 and 2010 ten consecutive children with high-energy open diaphyseal tibial fractures were treated by early reduction and application of a programmable circular external fixator. They were all male with a mean age of 11.5 years (5.2 to 15.4), and they were followed for a mean of 34.5 months (6 to 77). Full weight-bearing was allowed immediately post-operatively. The mean time from application to removal of the frame was 16 weeks (12 to 21). The mean deformity following removal of the frame was 0.15° (0° to 1.5°) of coronal angulation, 0.2° (0° to 2°) sagittal angulation, 1.1 mm (0 to 10) coronal translation, and 0.5 mm (0 to 2) sagittal translation. All patients achieved consolidated bony union and satisfactory wound healing. There were no cases of delayed or nonunion, compartment syndrome or neurovascular injury. Four patients had a mild superficial pin site infection; all settled with a single course of oral antibiotics. No patient had a deep infection or re-fracture following removal of the frame. The time to union was comparable with, or better than, other published methods of stabilisation for these injuries. The stable fixator configuration not only facilitates management of the accompanying soft-tissue injury but enables anatomical post-injury alignment, which is important in view of the limited remodelling potential of the tibia in children aged > ten years. Where appropriate expertise exists, we recommend this technique for the management of high-energy open tibial fractures in children


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 42 - 42
1 Jun 2023
Bridgeman P Heeley E
Full Access

Introduction. Introduction: Pin site infection is a common complication during treatment with a circular frame external fixator and increases time and support patients require from the limb reconstruction team. Wound swabs were not routinely sent by the clinical nurse specialists prior to this study, with most pin site infections treated as Staphylococcus aureus with flucloxacillin (clindamycin in penicillin allergy). The aim of this study was to ascertain whether routine sending of wound swabs in pin site infection would change antibiotic treatment. Materials & Methods. Materials and Method: Patients presenting at clinic or physiotherapy with clinical signs of pin site infection were assessed using the Maz Oxford Nuffield (MON) Pin Site Infection Grading System© (OUH, 2021). Antibiotics were commenced as per unit guidelines and swabs sent for microscopy, culture and sensitivity. Results. Results: There were forty patients treated with pin site infections. Swab results showed S. aureus in 60% (N=24), other organisms in 15% (N=6) and no growth or mixed skin organisms in 10% (N=10). Flucloxacillin was prescribed to 77.5% (n=31) of patients with the remaining 22.5% (n=9) of patients receiving clindamycin (due to allergy) or rifampicin and ciprofloxacin (due to a previous MRSA diagnosis). Antibiotic management was subsequently changed in only 5% (n=2) of patients due to one patient with a new MRSA diagnosis and one patient growing Enterobacter in three pin sites tested. Conclusions. Conclusion: This study has shown that routine swab testing of pin sites does not usually change antibiotic management but should still be used in multiple, severe or unresolving pin site infections


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_3 | Pages 16 - 16
1 Jan 2013
Zenios M Zamani F Oyadiji S
Full Access

Purpose of the study. The aim of this mechanical study was to investigate the ability of cannulated fixation bolts to stop wire slippage in Ilizarov circular external fixators. Methods and Results. Three types of cannulated fixation bolts (Smith and Nephew, Orthofix and one designed by the authors) were tested on Ilizarov rings to compare their performance. Three levels of bolt torques were applied and the wires were pulled to measure the load at which the wire will start to slip or fail. It was revealed that the initial resistance to slippage is due to plastic deformation of the wire under the clamp and is in fact governed by the size of this deformation. The slippage was found to occur in a slip/stick fashion, as the plastic deformation was propagated along the wire. Conclusion. The more the plastic deformation caused by the bolt on the wire the higher the initial resistance to loading


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 40 - 40
1 Dec 2015
Silva MD Wircker P Leitão F Martins R Côrte-Real N
Full Access

The aim of this abstract is to show that when dealing with an infected non-union, all possibilities of treatment must be considered in order to choose the best treatment plan for each patient. This case shows the evolution of an infected non-union following type III open fractures which, after the used of several methods that failed, had to be solved with amputation. We present a case report of a 41 years old man, with a type IIIA open fracture of the right tibia and fibula. Initially, he was treated with an external fixator, which was removed and plate implanted. After this, he who presented to us with an infected non-union. He was submitted to surgery, the plate was removed and a circular external fixator was used. Six months later, the external fixator was removed and a reamed intramedullary nail was implanted with bone graft from iliac crest. One year later, the facture site was still mobile, so he was submitted to fixation with internal plate. As this last method also failed, a bellow knee amputation was performed, 4 years after the initial event. After several attempts with several distinctive methods, the infected non-union had to be solved with the sacrifice of the limb. The treatment of infected non-union is one of the most difficult in Orthopedic Surgery. There are several procedure that can be used. When all these fail, amputation and consequent limb prosthetic substitution, might allow the patient to return to the society