Objectives. The paradoxical migration of the femoral neck element (FNE) superomedially against gravity, with respect to the intramedullary component of the cephalomedullary device, is a poorly understood phenomenon increasingly seen in the management of pertrochanteric hip fractures with the intramedullary nail. The aim of this study was to investigate the role of bidirectional loading on the medial migration phenomenon, based on unique wear patterns seen on scanning electron microscopy of retrieved implants suggestive of FNE toggling. Methods. A total of 18 synthetic femurs (Sawbones, Vashon Island, Washington) with comminuted pertrochanteric fractures were divided into three groups (n = 6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA) implant (Synthes, Oberdorf, Switzerland; n = 6). Group 1 was subjected to unidirectional compression loading (600 N), with an elastomer (70A durometer) replacing loose fracture fragments to simulate surrounding soft-tissue tensioning. Group 2 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading), also with the elastomer replacing loose fracture fragments. Group 3 was subjected to bidirectional loading (600 N compression loading, 120 N tensile loading) without the elastomer. All constructs were tested at 2 Hz for 5000 cycles or until cut-out occurred. The medial migration distance (MMD) was recorded at the end of the testing cycles. Results. The MMDs for Groups 1, 2, and 3 were 1.02 mm, 6.27 mm, and 5.44 mm respectively, with reliable reproduction of medial migration seen in all groups. Bidirectional loading groups showed significantly higher MMDs compared with the unidirectional loading group (p < 0.01). Conclusion. Our results demonstrate significant contributions of bidirectional cyclic loading to the medial migration phenomenon in
Aims. There are concerns regarding nail/medullary canal mismatch and initial stability after
Aims.
Objectives. Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. Methods. A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)). Results. The incidence of cut-out across the sample was 5.6%, with a higher incidence in female patients. A significantly higher risk of this complication was correlated with lag-screw tip positioning in the upper part of the femoral head in the anteroposterior radiological view, posterior in the latero-lateral radiological view, and in the Cleveland peripheral zones. The tip-apex distance and the calcar-referenced tip-apex distance were found to be highly significant predictors of the risk of cut-out at cut-offs of 30.7 mm and 37.3 mm, respectively, but the former appeared more reliable than the latter in predicting the occurrence of this complication. Conclusion. The tip-apex distance remains the most accurate predictor of cut-out, which is significantly greater above a cut-off of 30.7 mm. Cite this article: G. Caruso, M. Bonomo, G. Valpiani, G. Salvatori, A. Gildone, V. Lorusso, L. Massari. A six-year retrospective analysis of cut-out risk predictors in
Introduction. The vast majority of intertrochanteric fractures treated with
Aims. Restoration of proximal medial femoral support is the keystone in the treatment of intertrochanteric fractures. None of the available implants are effective in constructing the medial femoral support. Medial sustainable nail (MSN-II) is a novel
Twenty one cases of ipsilateral hip and femoral shaft fractures, between January 1998 and December 2001, managed by reconstruction nail were reviewed. All patients underwent simultaneous surgery for both fractures and operative treatment was executed as early as general condition of the patient permitted. Delay in treatment was generally because of associated injuries [head, chest or abdominal]. There were 20 males and 1female patients with an average age of 34.5 years. There was delayed diagnosis of neck fracture in 2 cases and these cases were not included in the study. Our average follow-up is 30.9 months. There was one case of nonunion of a femoral neck fracture, one case of avascular necrosis and one neck fracture that united in varus. There were 4 nonunions and 6 cases of delayed union of femoral shaft fractures. Mean time for union of femoral neck fracture was 15 weeks and for shaft fracture was 22 weeks. In our results, shaft fracture determined the total union period. Though complications involving the femoral shaft fracture were greater than the femoral neck fractures, the shaft complications were more manageable compared to neck complications. This stresses the need to realize the significance and seriousness of both components of this complex injury, in evaluation, management and postoperative care.
Aims. To compare the outcomes for trochanteric fractures treated with
a sliding hip screw (SHS) or a
Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting. Using our hospital system's trauma database, we identified 100 consecutive patients treated with
Introduction and Objective. Trochanteric fractures are associated with increasing incidence and represent serious adverse effect of osteoporosis. Their
Introduction.
Purpose:
The purpose of this study was to identify factors
that predict implant cut-out after
There has been evidence of association between femoral shaft fractures and prolonged bisphosphonate therapy. We present a case series of bisphosphonate-associated fractures and invaluable lessons we have learnt. Over the last three years at our unit we have collected a case series of eight patients who have had atypical femoral fractures whilst on bisphosphonate therapy. We present illustrative cases, a summary of key findings, and invaluable lessons we have learnt. There was a long period of prodromal pain for two years before incomplete fractures developed. We speculate this is a warning sign of impending fracture. This may have been prevented with screening. Between incomplete fracture and complete fracture there was a short window of one month. Five patients presented with complete fracture, and three with thigh pain +/- evidence of incomplete fracture. Of the latter group all but one went on to develop complete fractures. The one patient who did not progress died six years after diagnosis. Of those five patients who presented with initial complete fracture, three patients recall thigh pain before fracture on further questioning. Despite being diaphyseal femoral fractures, there is a higher risk of neck of femur fractures in this patient cohort (both patients with initial interlocked nails subsequently developed neck of femur fractures soon after and were revised to cephalomedullary nails). Excluding one death from unrelated cause, only one patient has signs of complete fracture healing. All other patients are still receiving follow-up (mean 490 days). Three patients reported bilateral symptoms (pain). Two had had bilateral symptoms for one year. Both had visible incomplete fractures on further radiographic scrutiny; one underwent prophylactic
Hip fractures frequently occur in elderly patients with osteoporosis and are rapidly increasing in prevalence owing to an increase in the elderly population and social activities. We experienced several recent presentations of TFNA nails failed through proximal locking aperture which requires significant revision surgery in often highly co-morbid patient population. The study was done by retrospective data collection from 2013 to 2023 of all the hip fractures which had been fixed with
Gunshot-induced fractures of the proximal femur typically present with severe comminution and bone loss. These fractures may also be associated with local damage to soft tissue, neurovascular structures and injuries to abdominal organs. The aim was to evaluate the outcomes of civilian gunshot injuries to the proximal femur at a major trauma center in South Africa. A retrospective review of all patients who sustained gunshot-induced proximal femur fractures between January 2014 and December 2017 was performed. Patients with gunshot injuries involving the hip joint, neck of femur or pertrochanteric fractures were included. Patient demographics, clinical- treatment and outcome data were collected. Results are reported as appropriate given the distribution of continuous data or as frequencies and counts. Our study included 78 patients who sustained 79 gunshot-induced proximal femur fractures. The mean age of patients was 31 ± 112, and the majority of patients were male (93.6%). Pertrochantenteric fractures were the most common injuries encountered (73.4%). Treatment included
Objectives: The purpose of the study is to evaluate the effectiveness of a new diagnostic protocol in identifying femoral neck fractures associated with ipsilateral shaft fractures and to study the clinical and functional outcome of these patients treated by
To present the results of femoral fracture treatment with long
Introduction. A long nail is often recommended for treatment of complex trochanteric fractures but requires longer surgical and fluoroscopy times. A possible solution could be a nail with an appropriate length which can be locked in a minimally invasive manner by the main aiming device. We aimed to determine if such a nail model* offers similar structural stability on biomechanical testing on artificial bone as a standard long nail when used to treat complex trochanteric fractures. Method. An artificial osteoporotic bone model was chosen. As osteosynthesis material two
Long femoral nails for neck of femur fractures and prophylactic fixation have a risk of anterior cortex perforation. Previous studies have demonstrated the radius of curvature (ROC) of a femoral nail influencing the finishing point of a nail and the risk of anterior cortex perforation. This study aims to calculate a patients femoral ROC using preoperative XR and CT and therefore nail finishing position. We conducted a retrospective study review of patients with long femoral