Advertisement for orthosearch.org.uk
Results 1 - 20 of 46
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 80 - 80
7 Nov 2023
Olivier A Vicatos G
Full Access

Custom 3D printed implants can be anatomically designed to assist in complex surgery of the bony pelvis in both orthopaedic oncology and orthopaedic reconstruction surgery. This series includes patients who had major pelvic bone loss after initially presenting with tumours, fractures or infection after previous total hip arthroplasty. The extent of the bone loss in the pelvis was severe and therefore impossible to be reconstructed by conventional ‘off –the-shelve’ implants. The implant was designed considering the remaining bony structures of the contra-lateral hemi- pelvis, to provide an anatomical, secured support for the reconstructed hip joint. The latter was realised by strategically orientated screws and by porous structures (an integral part of the implant), which stimulates osseointegration. A custom pelvic implant was designed, manufactured and 3D printed. Reconstruction of the pelvis was performed together with a cemented (bipolar bearing) acetabular cup. In some cases, a proximal femoral replacement was also necessary to compensate for bony defects. All patients had sufficient range of motion (ROM) at the hip with post-operative stability. It has been verified, at six and twelve months postoperatively, that there is a strong hold of the implant due to osseointegration. Additionally, in patients whose posterior acetabular wall was missing, it was discovered that the implant assisted in bone formation and covered the entire posterior surface of the implant. All patients in this study managed with this novel treatment option, proved to have a stable pelvic reconstruction with restoration of leg lengths, improvement of strength and independent ambulation at short and medium term follow-up


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 32 - 32
1 Oct 2022
Tøstesen S Stilling M Hanberg P Thillemann TM Falstie-Jensen T Tøttrup M Knudsen M Petersen ET Bue M
Full Access

Aim. Deadspace is the tissue and bony defect in a surgical wound after closure. This space is presumably poorly perfused favouring bacterial proliferation and biofilm formation. In arthroplasty surgery, an obligate deadspace surrounding the prosthesis is introduced and deadspace management, in combination with obtaining therapeutic prophylactic antibiotic concentrations, is important for limiting the risk of acquiring a periprosthetic joint infection (PJI). This study aimed to investigate cefuroxime distribution to an orthopaedic surgical deadspace in comparison with plasma and bone concentrations during two dosing intervals (8 h × 2). Method. In a setup imitating shoulder arthroplasty surgery, but without insertion of a prosthesis, microdialysis catheters were placed for cefuroxime sampling in a deadspace in the glenohumeral joint and in cancellous bone of the scapular neck in eighteen pigs. Blood samples were collected from a central venous catheter as a reference. Cefuroxime was administered according to weight (20 mg/kg). The primary endpoint was time above the cefuroxime minimal inhibitory concentration of the free fraction of cefuroxime for Staphylococcus aureus (fT > MIC (4 µg/mL)). Results. During the two dosing intervals, mean fT > MIC (4 µg/mL) was significantly longer in deadspace (605 min) compared with plasma (284 min) and bone (334 min). For deadspace, the mean time to reach 4 µg/mL was prolonged from the first dosing interval (8 min) to the second dosing interval (21 min), while the peak drug concentration was lower and half-life was longer in the second dosing interval. Conclusions. In conclusion, weight-adjusted cefuroxime fT > MIC (4 µg/mL) and elimination from the deadspace was longer in comparison to plasma and bone. Our results suggest a deadspace consolidation and a longer diffusions distance, resulting in a low cefuroxime turn-over. Based on theoretical targets, cefuroxime appears to be an appropriate prophylactic drug for the prevention of PJI. Acknowledgments. We would like to thank Department of Clinical Medicine, the surgical research laboratories, Aarhus University Hospital and Department of Clinical Biochemistry, Lillebaelt Hospital, Vejle, Denmark, for supporting this study. This research was funded by Novo Nordisk Foundation, grant number [NNF20OC0062032, 2020]


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 150 - 150
1 Mar 2017
Shon W Dwivedi C Kim T Kim H
Full Access

Although total hip arthroplasty is highly successful for treatment of osteoarthrosis of hip joint, it is skill demanding surgery to perform and even more challenging in case of revision with bone defects. There are many options available for reconstruction of acetabular bony defects. Here, we evaluate the outcome of acetabular bony defect reconstructed with trabecular metal augments in short term. We performed, 22 revision total hip arthroplasties and 6 primary total hip arthroplasties (total 28 in 28 patients) using trabecular metal augments to reconstruct acetabular defect between 2011 to 2015. Out of these 28 patients, 18 were males and 10 were females. Mean age of these patients was 61.2 years (range: 46 years to 79 years). Pre-operative templating was done for all cases and need for trabecular metal augments was anticipated in all cases. All cases were classified according to Paprosky classification for acetabular bone defects. Out of 28 patients, 3 had type 2B, 1 had type 2C, 18 had type 3A and 6 had type 3B acetabular defects. Post operatively, all patients were followed at regular interval for their clinical and radiological outcome. An average follow up was 20.1 months (range: 6 months to 42.5 months). We assessed clinical outcome in the form of Herris hip score (HHS) and radiological outcomes in form of osteolysis in acetabular zones and osseointegration, according to the criteria of Moore. The average Harris hip score (HHS) was improved from 58.0 preoperatively to 87.2 postoperatively. The average degree of cup abduction at the final follow up was 44.29. The centre of rotation of the hip joint was corrected from average 38.90mm (range: 22.15mm to 66.35mm) above the inter-teardrop line preoperatively to average 23.85mm (range: 11.82mm to 37.69mm) above the inter-teardrop line postoperatively. Out of 28 patients, 18 patients had three or more signs of osseointegration, according to the criteria of Moore, at the time of final follow up. Rest of patients, had one or two signs of osseointegration (5 patients had one sign and 5 patients had two signs). We had no patient with migration or loosening of acetabular components. No patient has osteolysis of acetabulum in any zone. Trabecular metal augments provide good initial stability to acetabular cup as well as helpful to bring down the centre of rotation of the hip joint within limit of 35mm above the inter-teardrop line. They also facilitate osseointegration. Our study showed that the results of the trabecular metal augments in reconstruction of acetabular bony defects were successful even in short term. However, long term study is required for better evaluation


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 121 - 121
1 Jan 2016
Kokubo Y Uchida K Sugita D Oki H Negoro K Inukai T Miyazaki T Nakajima H Yoshida A Baba H
Full Access

Total hip arthroplasty (THA) is one of the preferable solutions for regaining ambulatory activity for patients with end-stage osteoarthritis, and the procedure is well developed technically and large numbers of patients benefit from THA worldwide. However, despite the improvements in implant designs and surgical techniques, revision rates remain high, and the number of revisions is expected to increase in the future as a result of the increase in the volume of primary THA and the increase in the proportion of younger, more active patients who are likely to survive longer than their prosthetic implants. In revision THA, associated loss of bone stock in the acetabulum presents one of the major challenges. The aim of the present study was to analyze the clinical and radiographic outcomes and Kaplan-Meier survivorship of patients underwent revision surgeries of the acetabular cup sustaining aseptic loosening. We reviewed consecutive 101 patients (120 hips; 10 men 11 hips; 91 women 109 hips; age at surgery, 66 years, range, 45–85) who underwent acetabular component revision surgery, at a follow-up period of 14.6 years (range, 10–30). For the evaluation of the state of the acebtabulum, acetabular bony defects were classified according to the classification of the AAOS based on the intraoperative findings as follows; type I [segmental deficiencies] in 24 hips, type II [cavity deficiency] in 48 hips, type III [combined deficiency] in 46, and type IV [pelvic discontinuity] in 2. Basically, we used the implant for acetabular revision surgery that cement or cementless cups were for the AAOS type I acetabular defects, cementless cup, or cemented cup with reinforcement device were for type II, cemented cup with reinforcement device were for type III. Follow-up examination revealed that Harris Hip score improved from 42.5±7.8 points before surgery to 76±16.2 points (p<0.05). The survival rates of the acetabular revision surgery with cemented cups, cementless cups, and cemented cups with reinforcement devices were 65.1%, 72.8%, and 79.8%, respectively, however, there was no significant differences between the groups. There were nine cases, which failed in the early stage in the groups of cementless cups and cemented cups with reinforcement devices, because of the instability of the cementless cups or breakage of reinforcement plates caused by inadequate bone grafting. We conclude that the usage of the cementless cups for type I and II acetabular bony defects, and the cemented cups with reinforcement devices for type III bony defects will demonstrate durable long-term fixation in case of adequate contact between acetabular components and host-bone with restoration of bone stock by impaction bone grafting


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2016
Choi CH Chung KS Lee JK Lee HJ
Full Access

Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty. Materials and Methods. We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter. Results. At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews. Conclusions. The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period. Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 53 - 53
1 Dec 2017
Henckel J Durand-Hill M Noory S Skinner J Hart A
Full Access

Additive manufacturing has enabled a radical change in how surgeons reconstruct massive acetabular defects in revision hip surgery. We report on the early clinical and radiological results from our methods for surgical planning, design, and implantation of 3D printed trabecular titanium implants in a cohort of patients with large unclassifiable pelvic defects. We set up a prospective investigation involving 7 consecutive patients. Inclusion criteria was the following: 1) A history of previous total hip replacement; and 2) Current imaging showing at least a Paprosky 3B defect. Planned acetabular inclination and version was 40° and 20° respectively. Post operatively all patients had a CT scan which was analysed with software to determine component position and compared to planned. Outpatient review was done at 2 weeks (For wound), 6 weeks (for weight bearing and fixation) and 52 weeks (for fixation and infection) post-operative. The median age at surgery was: 65 years (40–78). The median bone defect volume was 140cm. 3. Median surgery length was 5.2 hours (3–6.25). Median blood loss was 1300mL (450– 2000). Radiologically, components were stable and no screw breakages were identified. Achieved inclination was 41.0° (29.0–55.6) and achieved version was 15.8° (3.8–43.6). Median Oxford Hip score improved from 9 (2–44) to 25 (18–32). We have demonstrated a new series of pre, intra and post-operative methods for reconstruction of unclassifiable acetabular bony defects. Initial clinical and radiological results are excellent considering the severity of the bony defects. We recommend the use of our or similar methods when trying to reconstruct these defects


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 91 - 91
1 May 2016
Nurkovic J Ramovic A Nurkovic S Kurtagic I Dolicanin Z
Full Access

Bone is capable of regeneration, and defects often heal spontaneously. However, cartilage, tendon, and ligament injuries usually result in replacement if the site by organized scar tissue, which is inferior to the native tissue. The osteogenic potential of mesenchymal stem cells (MSCs) has already been verified. MSCs hold great potential for the development of new treatment strategies for a host of orthopedic conditions. The multi-lineage potential and plasticity of MSCs allow them to be building blocks for a host of nonhematopoietic tissues, including bone. More recently, several groups have reported on the successful clinical application of tissue engineering strategies in the repair of bony defects in patients secondary to trauma and tumor resection. Advances in fabrication of biodegradable scaffolds that serve as beds for MSC implantation will hopefully lead to better biocompatibility and host tissue integration. Current strategies for bone tissue engineering include the use of osteoconductive matrix devices that promote bony ingrowth, and the delivery of osteoinductive growth factors, including bone morphogenetic protein (BMP) family, BMP-2 and BMP-7, to bony defect sites. Minimal toxicity has been observed in animal models involving genetically-manipulated stem cells transduced with retroviral and adenoviral vectors. Gene therapy using stem cells as delivery vehicles is a powerful weapon that can be used in a plethora of clinical situations that would benefit from the osteoinductive, proliferative, and angiogenic effects of growth factors. With better understanding of the biology of stem cells in the future and with enhancement of technologies that are capable to influence, modify, and culture these cells, a new field of regenerative skeletal medicine may emerge


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 4 - 4
1 May 2016
Lo H
Full Access

Introduction. Osteoporotic intertrochanteric fracture (ITF) is frequent injuries affecting elderly, osteoporotic patients leading to significant morbidity and mortality. Successful prognosis including union and alignment is challenging even though initial successful reduction with internal fixation. Although many factors are related to the patient's final prognosis. Well reduction with stable fracture fixation is still the goal of treatment to improve the quality of life and decrease morbidity in patients with hip fractures, but this in turn depends on the type of fracture and bone quality. Poor bone quality is responsible for common complications, such as failure of fixation, varus collapse and lag screw cut-out, in elderly patients. Kim et al. found that the complication rate when using conventional DHS in unstable ITFs can be as high as 50% because of screw cut-out. We used the dynamic hip screws (DHS) strengthened by calcium phosphate cement (CPC) for treatment femoral intertrochanteric fracture and review the prognosis of our patients. Materials and Methods. From January of 2011 to January of 2014, 42 patients with femoral intertrochanteric fracture underwent surgery with DHS strengthened by CPC. Comparisons were made between the DHS plus CPC group with the other patients with only DHS used in our department. All patients were followed up for an average time of 14.8(6 to 24) months. X-ray was reviewed for the conditions of union and implant failure. Results. In DHS group, fixation failure happened in 3 case, delayed union and coax varus deformity in 2 cases. IN DHS plus CPC group, all fractures healed uneventfully, there is no non-union or malunion in this group. There is only 1 fixation cut-out and 1 secondary lag screw sliding was noted, however, union was still well over fracture site in this case, the patient had no clinical symptoms. Discussion. Residual bony defects present after DHS fixation in intertrochanteric fracture may lead to postoperative complications, including nonunion or implant failure. DHS strengthened by CPC is reliable fixation for old patients with intertrochanteric fracture, We demonstrated that augmentation of the bony defect with dynamic hip screw by reinforced calcium phosphate cement significantly improved the strength of osteoporotic bone, prevent screw loosening, and promote early healing of fracture. The patients can be decreased the risk of refracture and allow early weight bearing, especially in elderly patients with osteoporotic bone


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 28 - 28
1 Dec 2014
van der Jagt D Pietzrak J Hanna M Mokete L
Full Access

Background:. Massive acetabular defects remain an unresolved challenge in revision arthroplasty surgery of the hip. We report on 7 patients treated with custom made acetabular components to manage these massive boney defects. Methods:. After high resolution CT scans were done, custom made implants were designed in collaboration between the surgeons and the manufacturer. All implants matched the bony defects as designed. Results:. There were 6 female and 1 male patients. The average age was 54 years, and on average each patient had had 9 previous revision procedures to the hip. All had Paprosky type 111B defects. The average surgical time for the procedure was 2.6 hours. The average time in hospital post-operation was 6 days. The average follow-up post index procedure was 13 months. Two implants needed to be explanted because of sepsis. One device was re-implanted after the infection was eradicated. One patient needed re-operation because of recurrent dislocations. All 6 surviving implants have remained well fixed with no radiological evidence of loosening. We did a cost analysis including the cost of the previous revision procedures, the cost of alternative acetabular hardware constructs, and the cost of the custom made implants. These custom made implants are cost effective in the clinical setting. Conclusion:. Massive acetabular bony defects remain an ongoing challenge, and we have presented a viable option in respect of these cases which is cost effective and durable in the short term


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 66 - 66
1 Jul 2020
Tat J Chong J Powell T Martineau PA
Full Access

Anterior shoulder instability is associated with osseous defects of the glenoid and/or humeral head (Hill-Sachs lesions). These defects can contribute to the pathology of instability by engaging together. There is a need to continue to develop methods to preoperatively identify engaging Hill-Sachs lesions for determining appropriate surgical management. The objective was to created a working moveable 3D CT model that allows the user to move the shoulder joint into various positions to assess the relationship between the Hill-Sachs lesion and the anterior glenoid rim. This technique was applied to a cohort series of 14 patients with recurrent anterior dislocation: 4 patients had undergone osteoarticular allografting of Hill-Sachs lesions and 10 control patients had undergone CT scanning to quantify bone loss but had no treatment to address bony pathology. A biomechanical analysis was performed to rotate each 3D model using local coordinate systems through a functional range using an open-source 3D animation program, Blender (Amsterdam, Netherlands). A Hill-Sachs lesion was considered “dynamically” engaging if the angle between the lesion's long axis and anterior glenoid was parallel. In the classical vulnerable position of the shoulder (abduction=90, external rotation=0–135), none of the Hill-Sachs lesions aligned with the anterior glenoid in any of our patients (Figure 1). Therefore, we considered there to be a “low risk” of engagement in these critical positions, as the non-parallel orientation represents a lack of true articular arc mismatch and is unlikely to produce joint instability. We then expanded our search and simulated shoulder positions throughout a physiological range of motion for all groups and found that 100% of the allograft patients and 70% of the controls had positions producing alignment and were “high risk” of engagement (p = 0.18) (Table 1). We also found that the allograft group had a greater number of positions that would engage (mean 4 ± 1 positions of engagement) compared to our controls (mean 2 ± 2 positions of engagement, p = 0.06). We developed a 3D animated paradigm to dynamically and non-invasively visualize a patient's anatomy and determine the clinical significance of a Hill-Sachs lesion using open source software and CT images. The technique demonstrated in this series of patients showed multiple shoulder positions that align the Hill-Sachs and glenoid axes that do not necessarily meet the traditional definition of engagement. Identifying all shoulder positions at risk of “engaging”, in a broader physiological range, may have critical implications towards selecting the appropriate surgical management of bony defects. We do not claim to doubt the classic conceptual definition of engagement, but we merely introduce a technique that accounts for the dynamic component of shoulder motion, and in doing so, avoid limitations of a static criteria assumed traditional definition (like size and location of lesion). Further investigations are planned and will help to further validate the clinical utility of this method. For any figures or tables, please contact the authors directly


The Bone & Joint Journal
Vol. 96-B, Issue 6 | Pages 829 - 836
1 Jun 2014
Ferguson JY Dudareva M Riley ND Stubbs D Atkins BL McNally MA

We report our experience using a biodegradable calcium sulphate antibiotic carrier containing tobramycin in the surgical management of patients with chronic osteomyelitis. The patients were reviewed to determine the rate of recurrent infection, the filling of bony defects, and any problems with wound healing. A total of 193 patients (195 cases) with a mean age of 46.1 years (16.1 to 82.0) underwent surgery. According to the Cierny–Mader classification of osteomyelitis there were 12 type I, 1 type II, 144 type III and 38 type IV cases. The mean follow-up was 3.7 years (1.3 to 7.1) with recurrent infection occurring in 18 cases (9.2%) at a mean of 10.3 months post-operatively (1 to 25.0). After further treatment the infection resolved in 191 cases (97.9%). Prolonged wound ooze (longer than two weeks post-operatively) occurred in 30 cases (15.4%) in which there were no recurrent infection. Radiographic assessment at final follow-up showed no filling of the defect with bone in 67 (36.6%), partial filling in 108 (59.0%) and complete filling in eight (4.4%). A fracture occurred in nine (4.6%) of the treated osteomyelitic segments at a mean of 1.9 years (0.4 to 4.9) after operation. We conclude that Osteoset T is helpful in the management of patients with chronic osteomyelitis, but the filling of the defect in bone is variable. Prolonged wound ooze is usually self-limiting and not associated with recurrent infection. Cite this article: Bone Joint J 2014; 96-B:829–36


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 1 - 1
1 Oct 2012
Fieten L Eschweiler J Kabir K Gravius S Randau T Radermacher K
Full Access

Cup position planning for total hip replacement (THR) is a complex task which is influenced by several factors. Whereas aspects like appropriate implant fixation and bone stock preservation are rather evaluated according to intra-operative findings, functional analyses using biomechanical hip models can rely on pre-operative imaging. Due to the wide availability and cost-efficiency of X-ray imaging technology along with the common restriction of biomechanical evaluations to the frontal plane, pre-operative imaging for such purposes is usually limited to AP radiographs. One example is biomechanical optimisation based on the so-called BLB score, which has already been introduced into clinical practice. In this approach, the assumed suitability of potential hip centres of rotation (CORs) is presented to the surgeon by applying colour-coding within the pre-operative AP radiograph. However, to realise the plan, the surgeon has to transfer the 2D positions presented in the radiograph into the 3D surgical site. We developed a CT-based simulation tool allowing for the generation of 3D bone surface models as well as standardised digitally reconstructed radiographs (DRRs). Within a 3D view, the cup, which is represented as a hemisphere, can freely be shifted in the coronal plane. The 2D point corresponding to the COR defined by the hemisphere is then automatically computed. In our study, four CT datasets of hips with large bony defects were used. After segmentation 3D bone surface models were generated. These bone surface models were aligned on the basis of the pelvic coordinate system [3], and standardised AP DRRs were computed. BLB score evaluation in intact hips assumes that the central beam passes through the centroid of both hip CORs. As only the contra-lateral hip COR was available due to the defects, a virtual ipsi-lateral COR was obtained by mirroring the contra-lateral hip across the mid-sagittal plane. Twelve surgeons (divided into two groups of six each according to their experience) had the task to shift the cup such that its 3D position would best match a predefined 2D target position, which was close to the virtual ipsi-lateral COR and displayed as a cross within the standardised DRR. However, the current 2D position corresponding to the current 3D position was not revealed during positioning. Once the user was satisfied with the 3D position, the corresponding 2D position was recorded. The following results were obtained (mean ± SD across six surgeons of the respective group) for the four patients:. x-error, more experienced: 2.0 ± 6.1; −3.0 ± 5.9; 4.1 ± 4.8; 2.1 ± 5.2; x-error, less experienced: 4.3 ± 4.2; −3.1 ± 1.8; 1.9 ± 4.0; 5.2 ± 4.1; |x-error|, more experienced: 5.2 ± 3.0; 5.4 ± 3.2; 5.5 ± 2.7; 4.3 ± 3.0;|x-error|, less experienced: 4.3 ± 4.2; 3.1 ± 1.8; 3.3 ± 2.7; 5.7 ± 3.3; y-error, more experienced: 12.0 ± 9.1; 0.3 ± 4.3; 6.2 ± 6.6; 1.9 ± 3.2;. y-error, less experienced: 6.1 ± 3.1; 0.8 ± 4.0; 2.4 ± 5.5; 1.4 ± 4.1;|y-error|, more experienced: 12.0 ± 9.1; 3.2 ± 2.6; 6.2 ± 6.6; 3.0 ± 1.9;|y-error|, less experienced: 6.1 ± 3.1; 3.4 ± 1.6; 4.6 ± 3.3; 3.2 ± 2.6;total error, more experienced: 13.5 ± 8.9; 6.6 ± 3.5; 9.8 ± 4.1; 5.4 ± 3.4;total error, less experienced: 8.5 ± 2.7; 4.9 ± 1.5; 6.5 ± 2.5; 6.7 ± 3.8. Our experimental results show that mental 2D/3D matching for cup positioning in pelvises with bony defects is a difficult task, and that mental 2D/3D matching cannot be expected to yield the correct 3D cup positions corresponding to positions predefined in radiographs. The largest errors were found in the patient with the lowest image quality suggesting that image quality plays an important role. On contrary, experience was not found to be an important factor. We believe that in clinical practice mental 2D/3D matching between pre-operative radiographs and the surgical site without the help of 3D imaging or special tools would be more difficult than the task given in this study because only small portions of the pelvis would be exposed. Furthermore, as additional aspects of cup positioning would need to be taken into consideration simultaneously, the mental load could be expected to be higher. We conclude that in hips with large bony defects cup positioning based on pre-operative radiographs is highly unreliable without additional computer-assistance or intra-operative imaging. If pre-operative radiographs are needed for functional analyses, combination with 3D image data seems attractive: Firstly, 3D images can easily be used for navigation; secondly, they allow for the generation of highly standardised views, which is essential for comparability across multiple patients. Future studies relying on more datasets with a wider range of defects could also investigate whether cranio-caudal or medio-lateral positioning errors prevail. This is an interesting question since the BLB score usually is much more specific in the medio-lateral direction than in the cranio-caudal direction, implying that correct 2D/3D matching for the cranio-caudal direction appears less important. In the current study involving only four hips, however, no clear tendency could be observed. This work has been funded in part by the German Ministry for Education and Research (BMBF) in the framework of the orthoMIT project under grant No. BMBF 01EQ0802/BMBF 01IBE02C


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 50 - 50
1 Dec 2013
Dong N Heffernan C Nevelos J Ries M
Full Access

Introduction:. Acetabular revision Jumbo cups are used in revision hip surgeries to allow for large bone to implant contact and stability. However, jumbo cups may also result in hip center elevation and instability. They may also protrude through anterior wall leading to ilopsoas tendinitis. Methods:. The study was conducted using two methods:. Computer simulation study. 265 pelvic CT scans consisting of 158 males and 107 females were converted to virtual 3-dimensional bones. The average native acetabular diameter was 52.0 mm, SD = 4.0 mm (males in 52.4 mm, SD = 2.8 mm and 46.4 mm, SD = 2.6 mm in females). Images were analyzed by custom CT analytical software (SOMA™ V.3.2). 1. and over-sized reaming was simulated. Four distinct points, located in and around the acetabular margins, were used to determine the reamer sphere. Points 1, 2, 3 were located at the inferior and inferior-medial acetabular margins, and Point 4 was located superiorly and posteriorly in the acetabulum to simulate a bony defect in this location, Point 4 was placed at 10%, 20%, 30%, 40%, 50% and 60% of the distance from the superior – posterior margin of the acetabular rim to the sciatic notch to simulate bony defects of increasing size. (Figure 1). Radiographical study. Retrospective chart review of patient records for all cementless acetabular revisions utilizing jumbo cups between January 1, 1998 and March 30, 2012 at UCFS (98 patients with 57 men, 41 women). Jumbo cups: ≥66 mm in males; <62 mm in females. Reaming was directed inferiorly to the level of the obturator foramen to place the inferior edge of the jumbo cup at the inferior acetabulum. To determine the vertical position of the hip center, a circle was first made around both the jumbo and the contralateral acetabular surfaces using Phillips iSite PACS software. The center of this circle was assumed to correspond to the “hip center”. The height of the hip center was estimated by measuring the height of a perpendicular line arising from the interteardrop line (TL) and ending at the hip center. Results:. The computer simulation and radiographic analysis deomonstrated similar results. The computer simulation predicted that the hip center shifted superiorly and anteriorly as the reamer size increased. The hip center shifted 0.27 mm superiorly and 0.02 mm anteriorly for every millimeter in diameter increased for the reaming. (Figure 2) Anterior column bone removal was increased 0.86 mm for every 1 mm of reamer size increase. (Figure 3). Results of radiographical study is shown in Table bellow:. Discussion:. Use of a jumbo cup in revision THA results in elevation of the hip center. Therefore a longer femoral head may be needed to compensate for hip center elevation when a jumbo cup is used. Reaming for a jumbo cup can also result in loss of anterior bone stock and protrusion of the cup anteriorly which may cause iliopsoas tendonitis


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 118 - 118
1 Jun 2018
Rodriguez J
Full Access

Bone loss creates a challenge to achieving fixation in revision TKR. Failure to achieve metaphyseal fixation is associated with failure in revision TKR. In the absence of cancellous bone for cement fixation, metaphyseal augments placed without cement have shown promise in achieving fixation. First generation augments were modular solid titanium sleeves attached to a taper at the base of the core implant. The introduction of tantalum with its favorable mechanical qualities markedly increased the utility and utilization of metaphyseal augments, with positive reports. These are either large augments where the bone is prepared with a burr, or later small cones placed with a cannulated broaching technique. Both have solved real problems, the first being limited by the reproducibility of bone preparation, and the second with excellent reproducibility of bone preparation but limited diameters. Other highly porous titanium surfaces have broadened the choices. Modern metaphyseal augments seek to add flexibility and options, specifically the use of offset stems. One tibial augment design features a reamed cone with a matching conical implant. Another option is based on an anatomic cone design with a single ream and a broached technique to optimise endosteal cortical bone contact. With each of these options, the augment can be placed wherever the remaining bone exists for fixation, even down to the metaphyseal-diaphyseal junction, and not limited to the area adjacent to the cut surface of bone. Once independent fixation is achieved, the intramedullary stem is cemented inside of it. Modern femoral augments are designed to sit either in the epiphyseal region, or the metaphysis. Cannulated reaming systems allow for preparation of complex asymmetrical double cone implants at the epiphysis. Metaphyseal implants are designed anatomically to sit deeper in the femoral bone, and can manage larger bony defects. Each system has benefits and compromises, and together they comprise increasingly powerful alternatives to manage extensive bone loss


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 66 - 66
1 Aug 2017
Haidukewych G
Full Access

There are many challenges facing the revision knee surgeon. Bony defects, ligamentous imbalance, and difficult gap balancing scenarios are common and require practical management strategies. Typically, an implant with the least amount of constraint necessary to provide a well-aligned, well-balanced arc of motion is preferred. Constraint in implants increases the stresses on both the bearing surfaces and the bony interfaces and may result in earlier mechanical failure of the implant. Despite this fact, there are situations where one cannot rely on a simple larger polyethylene post (such as found in CCK type devices) to balance gaps. The author prefers to choose hinge-type devices in situations that demonstrate massive gap imbalance (typically huge flexion gaps), situations with deficient extensor mechanisms that can result in recurvatum stresses, or in situations of global ligamentous instability. Techniques of supporting the bony interfaces with stems and sleeves may improve the longevity of these constructs. Complications are common, including extensor mechanism problems. Multiple studies have demonstrated reasonable results of hinged implants for these challenging revision scenarios, and the hinge should remain in the armamentarium of the revision surgeon


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2019
Dharia M Armacost J Son Y
Full Access

INTRODUCTION. Porous metal bone fillers are frequently used to manage bony defects encountered in revision total knee arthroplasty (rTKA). Compared to structural graft, porous metal bone fillers have shown significantly lower loosening and failure rates potentially due to osseointegration and increased material strength [1]. The strength of porous metal bone fillers used in lower extremities is frequently assessed using compression/shear/torsion test methods, adapted from spine standards. However, these basic methods may lack clinical relevance, and do not provide any insight on the relationship between patient activity and anticipated prosthesis performance. The goal of this study was to evaluate the response of bone fillers under different activities of daily living, in order to define physiologically relevant worst case biomechanics for component evaluation. METHODS. A bone filler tibial augment is shown in Figure 1. A test construct for tibial augments (half-block each for medial and lateral sides) is shown in Figure 2, along with compatible rTKA components. An additional void in the bone was filled using bone cement. Loading was applied through the tibiofemoral contact patches created on polyethylene tibial insert. Loading was used for two activities of daily living; walking and deep knee bend [2–3]. During walking, the tibiofemoral contact patch on the anterior tibial post gets loaded due to femoral hyperextension with 1.2xbody weight (BW), whereas the medial and lateral condyles get loaded with 3xBW compressive load. For deep knee bend, only the condyles get loaded with 4.34xBW. Compared to walking, 45% higher compressive load magnitude in deep knee bend located further posterior was anticipated to create a larger bending moment and induce higher stress on the half augments. A finite element analysis (FEA) was performed by modeling this test construct with a medium size tibial augment. All components were modeled using linear elastic material properties. All interfaces, including the augment-bone interface (representing full bony ingrowth construct) were modeled using bonded contact. The inferior surface of the bone analogue was constrained. Linear static analyses were performed and peak von mises stress predicted in the tibial augments was compared between activities. RESULTS. Deep knee bend resulted in 31% higher stresses in the tibial augments than for walking. High von mises stresses were mostly predicted at the superior/posterior aspect of the internal side of the augment and in the corners of the cutouts. Figure 3 presents the von mises stresses in the tibial augments for both loading scenarios. DISCUSSION. This study revealed that the 45% increased posterior compressive load associated with deep knee bend is a more significant factor than the moment applied to the post during walking gait for a hyperextended knee, when considering the stress in bone filler augments in revision TKA. The stress in the augments can depend on multiple factors and the proposed FEA method can be used to compare stresses in different porous material bone fillers to determine worst case for assessing its strength


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 113 - 113
1 Apr 2017
Haidukewych G
Full Access

There are many challenges facing the revision knee surgeon. Bony defects, ligamentous imbalance, and difficult gap balancing scenarios are common and require practical management strategies. Typically, am implant with the least amount of constraint necessary to provide a well-aligned, well-balanced arc of motion is preferred. Constraint in implants increases the stresses on both the bearing surfaces and the bony interfaces and may result in earlier mechanical failure of the implant. Despite this fact, there are situations where one cannot rely on a simple larger polyethylene post (such as found in CCK type devices) to balance gaps. The author prefers to choose hinge type devices in situations that demonstrate massive gap imbalance (typically huge flexion gaps), situations with deficient extensor mechanisms that can result in recurvatum stresses, or in situations of global ligamentous instability. Techniques of supporting the bony interfaces with stems and sleeves may improve the longevity of these constructs. Complications are common, including extensor mechanism problems. Multiple studies have demonstrated reasonable results of hinged implants for these challenging revision scenarios, and the hinge should remain in the armamentarium of the revision surgeon


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 17 - 17
1 Apr 2017
Abdel M
Full Access

Ten to 15% of the pelvic girdle tumors are primary malignant bone tumors, while about 80% are osseous metastases. Due to improved function, enhanced quality of life, and acceptable local recurrence rates, limb salvage surgery has replaced external hemipelvectomies in many cases of primary malignancies. However, large segmental bony defects and poor bone quality due to the disease process itself and subsequent treatment (i.e. chemotherapy and radiation) can make stable implant fixation difficult when performing a total hip arthroplasty (THA) for oncologic periacetabular lesions with concurrent fractures. Various methods are available to reconstruct the hemipelvis, and include large structural allografts, allograft-prosthetic composites (APCs), custom-made endoprostheses, modular saddle prostheses, and modular hemipelvis endoprostheses. However, short- and mid-term results from our institution indicate that tantalum reconstructions with adjuvant screw fixation and supplemental reinforcement cages provide reasonable improvement in clinical outcomes and stable fixation in situations with massive bone loss and compromised bone quality. On the femoral side, cemented fixation remains a viable option (including proximal femoral replacements), but uncemented distal fixation with extensively-porous coated cylindrical stems or modular fluted tapered stems can be considered if the disease process (or subsequent treatment) primarily affects the proximal femur. In addition to long-term fixation, post-operative dislocations remain a significant concern given the often compromised abductor mechanism


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1095 - 1100
1 Sep 2022
McNally MA Ferguson JY Scarborough M Ramsden A Stubbs DA Atkins BL

Aims

Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier.

Methods

A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 111 - 111
1 Feb 2017
Chun C Chun K Baik J Lee S
Full Access

Background. This study was conducted to assess the clinical and radiologic results of total knee arthroplasty (TKA) with an allogenic bone graft using varus-valgus constrained (VVC) prostheses in knees with severe bone defects and unstable neuropathy. Methods. This study included 20 knees of 16 patients who underwent TKA between August 2001 and January 2006 due to unstable knees with severe bone destruction resulting from neuropathic arthritis. At the time of surgery, the mean age of the patients was 56 years. The mean length of the follow-up period was 10.7 years. A VVC condylar prosthesis was used with an allogenic femoral head graft to reconstruct large bony defects. Clinical results were evaluated using the Hospital for Special Surgery (HSS), Knee Society (KS) function, and Western Ontario and McMaster Universities Osteoarthritis (WOMAC) scores. Three-dimensional computed tomography (3D-CT) was used to evaluate the radiological parameters, which included the tibiofemoral angle, loosening or osteolysis of components, and incorporation of the bone graft. Results. The preoperative mean HSS, KS function, and WOMAC scores were 40.5, 43.2, and 78.3, respectively, and these scores improved to 86.0, 64.6, and 33.8 at the final follow-up. The mean postoperative alignment was 6.1° of valgus angulation. One knee had instability, another knee had partial bony absorption, which was confirmed using 3D-CT, and the other 18 cases (90%) had satisfactory results. No cases experienced radiolucency, fracture, or infection. Conclusions. TKA with an allogenic bone graft using a VVC prosthesis provides a viable option for the treatment of severe bone defects with soft tissue insufficiency in neuropathic knee arthropathy. Level of Study: Level IV, therapeutic study