Custom 3D printed implants can be anatomically designed to assist in complex surgery of the bony pelvis in both orthopaedic oncology and orthopaedic reconstruction surgery. This series includes patients who had major pelvic bone loss after initially presenting with tumours, fractures or infection after previous total hip arthroplasty. The extent of the bone loss in the pelvis was severe and therefore impossible to be reconstructed by conventional ‘off –the-shelve’ implants. The implant was designed considering the remaining bony structures of the contra-lateral hemi- pelvis, to provide an anatomical, secured support for the reconstructed hip joint. The latter was realised by strategically orientated screws and by porous structures (an integral part of the implant), which stimulates osseointegration. A custom pelvic implant was designed, manufactured and 3D printed. Reconstruction of the pelvis was performed together with a cemented (bipolar bearing) acetabular cup. In some cases, a proximal femoral replacement was also necessary to compensate for
Aim. Deadspace is the tissue and
Although total hip arthroplasty is highly successful for treatment of osteoarthrosis of hip joint, it is skill demanding surgery to perform and even more challenging in case of revision with bone defects. There are many options available for reconstruction of acetabular
Total hip arthroplasty (THA) is one of the preferable solutions for regaining ambulatory activity for patients with end-stage osteoarthritis, and the procedure is well developed technically and large numbers of patients benefit from THA worldwide. However, despite the improvements in implant designs and surgical techniques, revision rates remain high, and the number of revisions is expected to increase in the future as a result of the increase in the volume of primary THA and the increase in the proportion of younger, more active patients who are likely to survive longer than their prosthetic implants. In revision THA, associated loss of bone stock in the acetabulum presents one of the major challenges. The aim of the present study was to analyze the clinical and radiographic outcomes and Kaplan-Meier survivorship of patients underwent revision surgeries of the acetabular cup sustaining aseptic loosening. We reviewed consecutive 101 patients (120 hips; 10 men 11 hips; 91 women 109 hips; age at surgery, 66 years, range, 45–85) who underwent acetabular component revision surgery, at a follow-up period of 14.6 years (range, 10–30). For the evaluation of the state of the acebtabulum, acetabular
Introduction. The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained
Additive manufacturing has enabled a radical change in how surgeons reconstruct massive acetabular defects in revision hip surgery. We report on the early clinical and radiological results from our methods for surgical planning, design, and implantation of 3D printed trabecular titanium implants in a cohort of patients with large unclassifiable pelvic defects. We set up a prospective investigation involving 7 consecutive patients. Inclusion criteria was the following: 1) A history of previous total hip replacement; and 2) Current imaging showing at least a Paprosky 3B defect. Planned acetabular inclination and version was 40° and 20° respectively. Post operatively all patients had a CT scan which was analysed with software to determine component position and compared to planned. Outpatient review was done at 2 weeks (For wound), 6 weeks (for weight bearing and fixation) and 52 weeks (for fixation and infection) post-operative. The median age at surgery was: 65 years (40–78). The median bone defect volume was 140cm. 3. Median surgery length was 5.2 hours (3–6.25). Median blood loss was 1300mL (450– 2000). Radiologically, components were stable and no screw breakages were identified. Achieved inclination was 41.0° (29.0–55.6) and achieved version was 15.8° (3.8–43.6). Median Oxford Hip score improved from 9 (2–44) to 25 (18–32). We have demonstrated a new series of pre, intra and post-operative methods for reconstruction of unclassifiable acetabular
Bone is capable of regeneration, and defects often heal spontaneously. However, cartilage, tendon, and ligament injuries usually result in replacement if the site by organized scar tissue, which is inferior to the native tissue. The osteogenic potential of mesenchymal stem cells (MSCs) has already been verified. MSCs hold great potential for the development of new treatment strategies for a host of orthopedic conditions. The multi-lineage potential and plasticity of MSCs allow them to be building blocks for a host of nonhematopoietic tissues, including bone. More recently, several groups have reported on the successful clinical application of tissue engineering strategies in the repair of
Introduction. Osteoporotic intertrochanteric fracture (ITF) is frequent injuries affecting elderly, osteoporotic patients leading to significant morbidity and mortality. Successful prognosis including union and alignment is challenging even though initial successful reduction with internal fixation. Although many factors are related to the patient's final prognosis. Well reduction with stable fracture fixation is still the goal of treatment to improve the quality of life and decrease morbidity in patients with hip fractures, but this in turn depends on the type of fracture and bone quality. Poor bone quality is responsible for common complications, such as failure of fixation, varus collapse and lag screw cut-out, in elderly patients. Kim et al. found that the complication rate when using conventional DHS in unstable ITFs can be as high as 50% because of screw cut-out. We used the dynamic hip screws (DHS) strengthened by calcium phosphate cement (CPC) for treatment femoral intertrochanteric fracture and review the prognosis of our patients. Materials and Methods. From January of 2011 to January of 2014, 42 patients with femoral intertrochanteric fracture underwent surgery with DHS strengthened by CPC. Comparisons were made between the DHS plus CPC group with the other patients with only DHS used in our department. All patients were followed up for an average time of 14.8(6 to 24) months. X-ray was reviewed for the conditions of union and implant failure. Results. In DHS group, fixation failure happened in 3 case, delayed union and coax varus deformity in 2 cases. IN DHS plus CPC group, all fractures healed uneventfully, there is no non-union or malunion in this group. There is only 1 fixation cut-out and 1 secondary lag screw sliding was noted, however, union was still well over fracture site in this case, the patient had no clinical symptoms. Discussion. Residual
Background:. Massive acetabular defects remain an unresolved challenge in revision arthroplasty surgery of the hip. We report on 7 patients treated with custom made acetabular components to manage these massive boney defects. Methods:. After high resolution CT scans were done, custom made implants were designed in collaboration between the surgeons and the manufacturer. All implants matched the
Anterior shoulder instability is associated with osseous defects of the glenoid and/or humeral head (Hill-Sachs lesions). These defects can contribute to the pathology of instability by engaging together. There is a need to continue to develop methods to preoperatively identify engaging Hill-Sachs lesions for determining appropriate surgical management. The objective was to created a working moveable 3D CT model that allows the user to move the shoulder joint into various positions to assess the relationship between the Hill-Sachs lesion and the anterior glenoid rim. This technique was applied to a cohort series of 14 patients with recurrent anterior dislocation: 4 patients had undergone osteoarticular allografting of Hill-Sachs lesions and 10 control patients had undergone CT scanning to quantify bone loss but had no treatment to address bony pathology. A biomechanical analysis was performed to rotate each 3D model using local coordinate systems through a functional range using an open-source 3D animation program, Blender (Amsterdam, Netherlands). A Hill-Sachs lesion was considered “dynamically” engaging if the angle between the lesion's long axis and anterior glenoid was parallel. In the classical vulnerable position of the shoulder (abduction=90, external rotation=0–135), none of the Hill-Sachs lesions aligned with the anterior glenoid in any of our patients (Figure 1). Therefore, we considered there to be a “low risk” of engagement in these critical positions, as the non-parallel orientation represents a lack of true articular arc mismatch and is unlikely to produce joint instability. We then expanded our search and simulated shoulder positions throughout a physiological range of motion for all groups and found that 100% of the allograft patients and 70% of the controls had positions producing alignment and were “high risk” of engagement (p = 0.18) (Table 1). We also found that the allograft group had a greater number of positions that would engage (mean 4 ± 1 positions of engagement) compared to our controls (mean 2 ± 2 positions of engagement, p = 0.06). We developed a 3D animated paradigm to dynamically and non-invasively visualize a patient's anatomy and determine the clinical significance of a Hill-Sachs lesion using open source software and CT images. The technique demonstrated in this series of patients showed multiple shoulder positions that align the Hill-Sachs and glenoid axes that do not necessarily meet the traditional definition of engagement. Identifying all shoulder positions at risk of “engaging”, in a broader physiological range, may have critical implications towards selecting the appropriate surgical management of
We report our experience using a biodegradable
calcium sulphate antibiotic carrier containing tobramycin in the surgical
management of patients with chronic osteomyelitis. The patients
were reviewed to determine the rate of recurrent infection, the
filling of
Cup position planning for total hip replacement (THR) is a complex task which is influenced by several factors. Whereas aspects like appropriate implant fixation and bone stock preservation are rather evaluated according to intra-operative findings, functional analyses using biomechanical hip models can rely on pre-operative imaging. Due to the wide availability and cost-efficiency of X-ray imaging technology along with the common restriction of biomechanical evaluations to the frontal plane, pre-operative imaging for such purposes is usually limited to AP radiographs. One example is biomechanical optimisation based on the so-called BLB score, which has already been introduced into clinical practice. In this approach, the assumed suitability of potential hip centres of rotation (CORs) is presented to the surgeon by applying colour-coding within the pre-operative AP radiograph. However, to realise the plan, the surgeon has to transfer the 2D positions presented in the radiograph into the 3D surgical site. We developed a CT-based simulation tool allowing for the generation of 3D bone surface models as well as standardised digitally reconstructed radiographs (DRRs). Within a 3D view, the cup, which is represented as a hemisphere, can freely be shifted in the coronal plane. The 2D point corresponding to the COR defined by the hemisphere is then automatically computed. In our study, four CT datasets of hips with large
Introduction:. Acetabular revision Jumbo cups are used in revision hip surgeries to allow for large bone to implant contact and stability. However, jumbo cups may also result in hip center elevation and instability. They may also protrude through anterior wall leading to ilopsoas tendinitis. Methods:. The study was conducted using two methods:. Computer simulation study. 265 pelvic CT scans consisting of 158 males and 107 females were converted to virtual 3-dimensional bones. The average native acetabular diameter was 52.0 mm, SD = 4.0 mm (males in 52.4 mm, SD = 2.8 mm and 46.4 mm, SD = 2.6 mm in females). Images were analyzed by custom CT analytical software (SOMA™ V.3.2). 1. and over-sized reaming was simulated. Four distinct points, located in and around the acetabular margins, were used to determine the reamer sphere. Points 1, 2, 3 were located at the inferior and inferior-medial acetabular margins, and Point 4 was located superiorly and posteriorly in the acetabulum to simulate a
Bone loss creates a challenge to achieving fixation in revision TKR. Failure to achieve metaphyseal fixation is associated with failure in revision TKR. In the absence of cancellous bone for cement fixation, metaphyseal augments placed without cement have shown promise in achieving fixation. First generation augments were modular solid titanium sleeves attached to a taper at the base of the core implant. The introduction of tantalum with its favorable mechanical qualities markedly increased the utility and utilization of metaphyseal augments, with positive reports. These are either large augments where the bone is prepared with a burr, or later small cones placed with a cannulated broaching technique. Both have solved real problems, the first being limited by the reproducibility of bone preparation, and the second with excellent reproducibility of bone preparation but limited diameters. Other highly porous titanium surfaces have broadened the choices. Modern metaphyseal augments seek to add flexibility and options, specifically the use of offset stems. One tibial augment design features a reamed cone with a matching conical implant. Another option is based on an anatomic cone design with a single ream and a broached technique to optimise endosteal cortical bone contact. With each of these options, the augment can be placed wherever the remaining bone exists for fixation, even down to the metaphyseal-diaphyseal junction, and not limited to the area adjacent to the cut surface of bone. Once independent fixation is achieved, the intramedullary stem is cemented inside of it. Modern femoral augments are designed to sit either in the epiphyseal region, or the metaphysis. Cannulated reaming systems allow for preparation of complex asymmetrical double cone implants at the epiphysis. Metaphyseal implants are designed anatomically to sit deeper in the femoral bone, and can manage larger
There are many challenges facing the revision knee surgeon.
INTRODUCTION. Porous metal bone fillers are frequently used to manage
There are many challenges facing the revision knee surgeon.
Ten to 15% of the pelvic girdle tumors are primary malignant bone tumors, while about 80% are osseous metastases. Due to improved function, enhanced quality of life, and acceptable local recurrence rates, limb salvage surgery has replaced external hemipelvectomies in many cases of primary malignancies. However, large segmental
Excision of chronic osteomyelitic bone creates a dead space which must be managed to avoid early recurrence of infection. Systemic antibiotics cannot penetrate this space in high concentrations, so local treatment has become an attractive adjunct to surgery. The aim of this study was to present the mid- to long-term results of local treatment with gentamicin in a bioabsorbable ceramic carrier. A prospective series of 100 patients with Cierny-Mader Types III and IV chronic ostemyelitis, affecting 105 bones, were treated with a single-stage procedure including debridement, deep tissue sampling, local and systemic antibiotics, stabilization, and immediate skin closure. Chronic osteomyelitis was confirmed using strict diagnostic criteria. The mean follow-up was 6.05 years (4.2 to 8.4).Aims
Methods
Background. This study was conducted to assess the clinical and radiologic results of total knee arthroplasty (TKA) with an allogenic bone graft using varus-valgus constrained (VVC) prostheses in knees with severe bone defects and unstable neuropathy. Methods. This study included 20 knees of 16 patients who underwent TKA between August 2001 and January 2006 due to unstable knees with severe bone destruction resulting from neuropathic arthritis. At the time of surgery, the mean age of the patients was 56 years. The mean length of the follow-up period was 10.7 years. A VVC condylar prosthesis was used with an allogenic femoral head graft to reconstruct large