Advertisement for orthosearch.org.uk
Results 1 - 20 of 51
Results per page:
The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1256 - 1260
14 Sep 2020
Kader N Clement ND Patel VR Caplan N Banaszkiewicz P Kader D

Aims

The risk to patients and healthcare workers of resuming elective orthopaedic surgery following the peak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been difficult to quantify. This has prompted governing bodies to adopt a cautious approach that may be impractical and financially unsustainable. The lack of evidence has made it impossible for surgeons to give patients an informed perspective of the consequences of elective surgery in the presence of SARS-CoV-2. This study aims to determine, for the UK population, the probability of a patient being admitted with an undetected SARS-CoV-2 infection and their resulting risk of death; taking into consideration the current disease prevalence, reverse transcription-polymerase chain reaction (RT-PCR) testing, and preassessment pathway.

Methods

The probability of SARS-CoV-2 infection with a false negative test was calculated using a lower-end RT-PCR sensitivity of 71%, specificity of 95%, and the UK disease prevalence of 0.24% reported in May 2020. Subsequently, a case fatality rate of 20.5% was applied as a worst-case scenario.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 28 - 28
10 May 2024
Warindra T
Full Access

Discoid meniscus (DM) is a congenital variant of the knee joint that involves morphological and structural deformation, with potential meniscal instability. The prevalence of the Discoid Lateral Meniscus (DLM) is higher among the Asians than among other races, and both knees are often involved. Meniscal pathology is widely prevalent in the adult population, secondary to acute trauma and chronic degeneration. The true prevalence in children remains unknown, as pathologies such as discoid menisci often go undiagnosed, or are only found incidentally. A torn or unstable discoid meniscus can present with symptoms of knee pain, a snapping or clicking sensation and/or a decrease in functional activity, although it is not known if a specific presentation is indicative of a torn DM. While simple radiographs may provide indirect signs of DLM, magnetic resonance imaging (MRI) and arthroscopy is essential for diagnosis and treatment planning. Asymptomatic patients require close follow-up without surgical treatment, while patients with symptoms often require surgery. Partial meniscectomy is currently considered the treatment of choice for DLM. For children are more likely to achieve better results after partial meniscectomy


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 22 - 22
1 Dec 2022
Werle J Kearns S Bourget-Murray J Johnston K
Full Access

A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up. A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels. Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant. This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year. Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 82 - 82
1 Dec 2022
Negm A Schneider S Vaile K Yee S Lienhard K Schneider P
Full Access

Guidelines for the use of preoperative blood tests for elective surgery were established. However, there is less evidence and no guidelines regarding using these tests when a young, healthy patient undergoes minor orthopaedic trauma surgery. Bloodwork is often ordered routinely, regardless of medical history or the nature of the injury. We hypothesized that unnecessary blood work is requested for younger pre-operative patients, and their results will not change peri-operative management. This practice is not a judicious use of healthcare resources. This study aimed to evaluate the frequency, type, cost, and impact on clinical decisions if standard preoperative bloodwork was completed in healthy patients requiring surgical management of a minor fracture or dislocation. After the approval of our institutional ethics board, a retrospective chart review was conducted. Inclusion criteria were patients aged 18-60 years, who had an isolated minor orthopaedic trauma requiring outpatient surgery, who were American Society of Anesthesiologists (ASA) class 1. ASA class 1 is defined as “a normal healthy patient, without any clinically important comorbidity and without a clinically significant past/present medical history.” Data records from January 1, 2016, to December 31, 2018, were extracted from a provincial database (the Analytics Data Integration, Measurement and Reporting) for five hospitals. Data including demographics, surgical treatment, type and number of blood tests ordered, and ordering physician were collected. Any abnormal test results were checked to see whether they led to a change in patient management or related to a postoperative adverse event. Independent samples t-tests and Chi-square tests were used to compare the characteristics of patients who had preoperative bloodwork versus those who did not. The cost of preoperative blood work was estimated. During these two years, 627 patients met inclusion criteria, and 27% (n=168) of these patients had bloodwork completed pre-operatively, while only 34% (n=57) of these had one or more abnormal laboratory parameters. These abnormalities were minor and did not alter clinical management or result in repeated bloodwork peri-operatively. Patients who had bloodwork were significantly older (40.2 years) compared with patients without preoperative blood work (37.8 years; p=0.03), but there was no difference in sex between those who had bloodwork (53.4% male) and those who did not (51.4% male; p=0.63). The most common blood test ordered was a complete blood count, and the most commonly abnormal result was a mildly elevated white blood cell count (19%; n= 29). The most common patients to receive bloodwork were those with ankle (34%) and distal radius (34%) fractures. The bloodwork was primarily ordered by clinical associates (26%; n=46) and emergency department physicians (22%; n=38). Without considering lab personnel, consumables, and analysis time, the cost of this bloodwork was approximately $7685, an average of $45 per patient. Pre-operative bloodwork in young, healthy, asymptomatic patients requiring outpatient surgery for minor orthopaedic trauma had no clinical significance and did not change patient management. Rigorous prospective research is warranted to establish national guidelines for appropriate pre-operative bloodwork ordering to minimize unnecessary and costly investigations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 3 - 3
10 Feb 2023
Sundaram A Woods J Clifton L Alt V Clark R Carey Smith R
Full Access

Complex acetabular reconstruction for oncology and bone loss are challenging for surgeons due to their often hostile biological and mechanical environments. Titrating concentrations of silver ions on implants and alternative modes of delivery allow surgeons to exploit anti-infective properties without compromising bone on growth and thus providing a long-term stable fixation. We present a case series of 12 custom acetabular tri-flange and custom hemipelvis reconstructions (Ossis, Christchurch, New Zealand), with an ultrathin plasma coating of silver particles embedded between layers of siloxane (BioGate HyProtect™, Nuremberg, Germany). At the time of reporting no implant has been revised and no patient has required a hospital admission or debridement for a deep surgical site infection. Routine follow up x-rays were reviewed and found 2 cases with loosening, both at their respective anterior fixation. Radiographs of both cases show remodelling at the ilium indicative of stable fixation posteriorly. Both patients remain asymptomatic. 3 patients were readmitted for dislocations, 1 of whom had 5 dislocations within 3 weeks post-operatively and was immobilised in an abduction brace to address a lack of muscle tone and has not had a revision of their components. Utilising navigation with meticulous implant design and construction; augmented with an ultrathin plasma coating of silver particles embedded between layers of siloxane with controlled and long-term generation of silver ion diffusion has led to outstanding outcomes in this series of 12 custom acetabular and hemipelvis reconstructions. No patients were revised for infection and no patients show signs of failure of bone on growth and incorporation. Hip instability remains a problem in these challenging mechanical environments and we continue to reassess our approach to this multifaceted problem


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 11 - 11
1 Jun 2023
Doherty C McKee CM Foster A
Full Access

Introduction. Non-union is an unfortunate outcome of the fracture healing process for some patients; with an estimated annual incidence of 17.4- 18.9 per 100,00. The management of these patients depicts a significant clinical challenge for surgeons and financial burden to health services. External ultrasound stimulation devices (Exogen. TM. ) have been highlighted as a novel non invasive therapy to achieve union in cases of delayed and non-union. The aim of the current study was to assess the rate of union in patients using Exogen. TM. therapy for delayed fracture union in a district general hospital. Materials & Methods. This is a single centre retrospective continuous cohort study. Patients were identified from a prospective database of all patients prescribed Exogen. TM. therapy between June 2013- September 2021 in a district general hospital. Patient data was collected retrospectively using electronic patient records. Fracture union was assessed both clinically and radiographically and recorded in patient records. Failure of treatment was defined as progression to operative treatment due to lack of progression with ultrasound therapy or established asymptomatic non-union. Patient were excluded from the study if Exogen. TM. therapy was prescribed within 6 weeks of injury. Results. 142 potential patient were identified from the database. 35 patients were excluded from the data set (17 patients due to insufficient data available, 9 lost to follow up, 4 died and 5 excluded due to early application of Exogen. TM. therapy). 58 Patients progressed to union with an average time to union of 41 weeks. 49 cases failed to progress to union, of which 7 cases had conversion to operative management prior to completion of single course of Exogen. TM. therapy and were excluded from all other data review. 12% of cases that failed to unite with ultrasound therapy required multiple operations to establish union. Conclusions. A union rate of 58% was reported by the current study, which is lower than previously published. This likely reflects the heterogenous nature of the patient population and fracture distribution included. However, this is potentially a more reflective union rate for the general population than previously published. There were no adverse events associated with the use of Exogen. TM. therapy in the current study. Therefore supporting its use as a first line management to promote union in delayed fracture union in the general population. Additionally, failure to achieve fracture union with utilisation of Exogen. TM. therapy was associated with risk for requirement of multiple surgeries to achieve union. This could serve as an indicator for surgeon to consider the requirement additional measures at the initial surgical procedure


Bone & Joint Open
Vol. 1, Issue 6 | Pages 287 - 292
19 Jun 2020
Iliadis AD Eastwood DM Bayliss L Cooper M Gibson A Hargunani R Calder P

Introduction. In response to the COVID-19 pandemic, there was a rapidly implemented restructuring of UK healthcare services. The The Royal National Orthopaedic Hospital, Stanmore, became a central hub for the provision of trauma services for North Central/East London (NCEL) while providing a musculoskeletal tumour service for the south of England, the Midlands, and Wales and an urgent spinal service for London. This study reviews our paediatric practice over this period in order to share our experience and lessons learned. Our hospital admission pathways are described and the safety of surgical and interventional radiological procedures performed under general anaesthesia (GA) with regards to COVID-19 in a paediatric population are evaluated. Methods. All paediatric patients (≤ 16 years) treated in our institution during the six-week peak period of the pandemic were included. Prospective data for all paediatric trauma and urgent elective admissions and retrospective data for all sarcoma admissions were collected. Telephone interviews were conducted with all patients and families to assess COVID-19 related morbidity at 14 days post-discharge. Results. Overall, 100 children underwent surgery or interventional radiological procedures under GA between 20 March and 8 May 2020. There were 35 trauma cases, 20 urgent elective orthopaedic cases, two spinal emergency cases, 25 admissions for interventional radiology procedures, and 18 tumour cases. 78% of trauma cases were performed within 24 hours of referral. In the 97% who responded at two weeks following discharge, there were no cases of symptomatic COVID-19 in any patient or member of their households. Conclusion. Despite the extensive restructuring of services and the widespread concerns over the surgical and anaesthetic management of paediatric patients during this period, we treated 100 asymptomatic patients across different orthopaedic subspecialties without apparent COVID-19 or unexpected respiratory complications in the early postoperative period. The data provides assurance for health care professionals and families and informs the consenting process. Cite this article: Bone Joint Open 2020;1-6:287–292


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 57 - 57
1 Apr 2019
Borton Z Nicholls A Mumith A Pearce A Briant-Evans T Stranks G Britton J Griffiths J
Full Access

Aims. Metal-on-metal total hip replacements (MoM THRs) are frequently revised. However, there is a paucity of data on clinical outcomes following revision surgery in this cohort. We report on outcomes from the largest consecutive series of revisions from MoM THRs and consider pre-revision factors which were prognostic for functional outcome. Materials and Methods. A single-centre consecutive series of revisions from MoM THRs performed during 2006–2015 was identified through a prospectively maintained, purpose-built joint registry. The cohort was subsequently divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score (OHS)). Secondary outcomes were complication data, pre- and post-revision serum metal ions and modified Oxford classification of pre-revision magnetic resonance imaging (MRI). In addition, the study data along with demographic data was interrogated for prognostic factors informing on post-revision functional outcome. Results. 180 revisions in 163 patients were identified at a median follow-up of 5.48 (2–11.7) years. There were 152 (84.4%) in the symptomatic subgroup and 28 (15.6%) in the asymptomatic group. Overall median OHS improved from 29 to 37 with revision (P<0.001). Symptomatic patients experienced greater functional benefit (DOHS 6.5 vs. 1.4, p=0.012) compared to asymptomatic patients, though they continued to report inferior outcomes (OHS 36.5 vs 43, p=0.004). The functional outcome of asymptomatic patients was unaffected by revision surgery (pre-revision OHS 41, post-revision OHS 43, p=0.4). Linear regression analysis confirmed use of a cobalt-chrome (CoCr)-containing bearing surface (MoM or metal-on- polyethylene) at revision and increasing BMI were predictive of poor functional outcome (R. 2. 0.032, p=0.0224 and R. 2. 0.039, p=0.015 respectively). Pre- and post-revision serum metal ions and pre-revision MRI findings were not predictive of outcome. The overall complication rate was 36% (n=65) with a re-revision rate of 6.7%. The most common complication was ongoing adverse reaction to metal debris (ARMD, defined as positive post-revision MRI) in 21.1%. The incidence of ongoing ARMD was not significantly different between those with CoCr reimplanted and those without (p=0.12). Conclusions. To our knowledge, our study represents the largest single-centre consecutive series of revision THRs from MoM bearings in the literature. Symptomatic patients experience the greatest functional benefit from revision surgery but do not regain the same level of function as patients who were asymptomatic prior to revision. The re-implantation of CoCr as a primary bearing surface and increasing BMI was associated with poorer functional outcome


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 20 - 20
1 Jul 2020
Beausejour M Parent S Dallaire P Thibeault F El-Hawary R Sanders J Yaszay B Akbarnia B Tohme P Roy-Beaudry M
Full Access

This study addresses a crucial gap in the knowledge of normative spinal growth in children. The objective of this study is to provide detailed and accurate 3D reference values for global and segmental spinal dimensions in healthy children under the age of 11. Radiographic spine examinations of healthy children conducted to rule out scoliosis were reviewed in four scoliosis referral centers in North America. All consecutive children aged three to eleven years old with EOS biplanar good quality x-rays, but without diagnosed growth-affecting pathologies, were included. Postero-Anterior and Lateral calibrated x-rays were used for spine 3D reconstruction and computation of vertebral body height and spine length. Median and interquartile range were calculated from cross-sectional data. Smooth centiles growth curves for 3D True Spinal Length (3DTSL) between T1 and S1, as well as for mid-vertebral heights of T5, T12 and L3, where fit and calibrated from data using the Lambda-Mu-Sigma method (GAMLSS package for R). This method automatically selects the best performing distribution from a familly of choices. Tables of centiles were then predicted from the computed models for selected ages. A total of 638 full spine examinations from asymptomatic patients were reconstructed in 3D, 397 in girls and 241 in boys. Medians and interquartile ranges were calculated for 3DTSL (T1-S1): 285 (24) mm, 314 (26) mm and 349 (31) mm, and for selected vertebral heights T5: 10 (1) mm, 11 (1) mm and 12 (1) mm, T12: 13 (2) mm, 14 (1) mm and 16 (2) mm, and L3: 14 (1) mm, 16 (2) mm and 18 (2) mm, respectively for the 3–6, 6–8 and 8–11 age groups. Centile curves ready for clinical use of the 3DTSL (T1-S1) and of the vertebral heights of T5, T12 and L3 as a function of age were derived for the 5, 10, 25, 50, 75, 90 and 95th centiles. In general, boys presented linear relationships between spinal dimensions and age, and girls presented more diverging trends with increased variance for older ages. Accordingly curves for boys follow the Normal distribution whereas those for girls follow the original Box-Cox-Cole-Green distribution. Model diagnostic tests (normally distributed residuals, adequate wormplots and |Z statistics| < 2) confirmed adequacy of the models and the absence of significant misfit. Accurate reference values were derived for spinal dimensions in healthy children. Spinal dimension charts showed that the spinal lengths and vertebral heights changed relatively constantly across the age groups closely resembling WHO total body height charts. The reference values will help physicians better assess their patients' growth potential. It could also be used to predict expected spinal dimensions at maturity or changes in pathologic conditions as well as to assess the impact of growth friendly interventions in the correction of spinal deformities


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 68 - 68
1 Jul 2020
Hall D Pourzal R Jacobs J Urban R
Full Access

Little is known about the relationship between head-neck corrosion and its effect on the periprosthetic tissues and distant organs of patients hosting well-functioning devices. The purpose of this study was to investigate in postmortem retrieved specimens the degree and type of taper damage, and the corresponding histologic responses in periprosthetic tissues and distant organs. Fifty postmortem THRs (34 primaries, 16 revisions) retrieved after 0.5 to 26 years were analyzed. Forty-three implants had a CoCrMo stem and seven had a Ti6Al4V stem. All heads were CoCrMo and articulated against polyethylene cups (19 XLPE, 31 UHMWPE). H&E sections of joint pseudocapsules, liver, spleen, kidneys and lymph nodes were graded 1–4 for the intensity of various inflammatory cell infiltrates and tissue characteristics. Corrosion damage of the taper surfaces was assessed using visual scoring and quantitated with an optical coordinate measuring machine. SEM analysis was used to determine the acting corrosion mode. Polyethylene wear was assessed optically. The majority of tapers had minimal to mild damage characterized by local plastic deformation of machining line peaks. Imprinting of the stem topography onto the head taper surface was observed in 18 cases. Column damage on the head taper surface occurred in three cases. All taper surfaces scored moderate or severe exhibited local damage features of fretting and/or pitting corrosion. Moderate or severe corrosion of the head and/or trunnion was present in nine hips. In one asymptomatic patient with bilateral hips, lymphocyte-dominated tissue reactions involving perivascular infiltrates of lymphocytes and plasmacytes were observed. In this patient, mild, focal lymphocytic infiltrates were also present in the liver and kidneys, and there was focal histiocytosis and necrosis of the para-aortic lymph nodes. These two implants, which had been in place for 58.6 and 60.1 months, had severe intergranular corrosion of the CoCrMo trunnion, and column damage and imprinting on the head taper. In the other 41 hips, macrophage responses in the joint pseudocapsule to metallic and/or polyethylene wear particles ranged widely from minimal to marked. Focal necrosis in the pseudocapsules of 12 arthroplasties was related to high concentrations of CoCrMo, TiAl4V, TiO, BaSO4 and polyethylene wear particles. High concentrations of these particles were also detected in para-aortic lymph nodes. Rare to mild macrophages were observed in liver and spleen. This is a comprehensive study of wear and corrosion within well-functioning postmortem retrieved THRs, and the resulting local and distant tissue reactions. One of eight patients with moderate or severe corrosion did have a subclinical inflammatory response dominated by lymphocytes after five years. To what extent such an inflammatory process might progress to become symptomatic is not known. Ionic and particulate products generated by corrosion disseminated systemically. The minor lymphocytic infiltrate in the liver and kidneys of one subject with bilateral severely corroded head-neck junctions might suggest possible metal toxicity. The diagnosis of adverse tissue reactions to corrosion of modular junctions can be challenging. Postmortem retrieval studies add to our understanding of the nature and progression of lymphocyte-dominated adverse local and potentially systemic tissue reactions to corrosion of modular junctions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 109 - 109
1 Sep 2012
Masri BA Williams DH Greidanus NV Duncan CP Garbuz DS
Full Access

Purpose. There is a postulated association between increased serum metal ions and pseudotumour formation in patients with metal-on-metal hip replacements. The primary aim of this study was to assess the prevalence of pseudotumour in 31 asymptomatic patients with a large femoral head (LFH) metal-on-metal hip implant. This was compared to the prevalence of pseudotumour in 20 matched asymptomatic patients with a hip resurfacing (HRA) and 24 matched asymptomatic patients with a standard metal-on-polyethylene (MOP) total hip. A secondary objective was to assess possible correlation between increased serum metal ions and pseudotumour formation. Method. Ultrasound examination of the three groups was performed at a minimum follow up of two years. Serum metal ions were measured in the metal-on-metal LFH and HRA groups at a minimum of two years. Results. There were 10 (32%) solid or cystic masses in the LFH group with a mean size of 89.3 (8 to 437) cm3. In the HRA group there were five (25%) masses with a mean size of 41.6 (6 to 119) cm3. In the MOP group there was one cystic mass measuring 9.8 cm3. Median serum cobalt and chromium ion levels in the LFH group were 4.50 gL (interquartile range, 2.38 to 7.47) and 2.82 gL (interquartile range, 1.48 to 3.18) compared to 0.83 gL (interquartile range, 0.65 to 1.12) and 1.08 gL (interquartile range, 0.78 to 1.31) in the HRA group. Conclusion. This study demonstrates a significantly higher prevalence of pseudotumours in patients with large head metal-on-metal total hips. The higher levels of metal ions in this group suggest that elevated metal ions may lead to pseudotumour formation


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_6 | Pages 8 - 8
1 May 2015
Angel C McNair R Fuller N Sexton S
Full Access

All patients with a MOM THR implanted at our unit were recalled for clinical examination, Oxford hip score, radiographs, MARS MRI and cobalt/chromium ion levels. Patients were sub-classified, determining further follow up: a regular screening programme or referral to a revision arthroplasty surgeon. We identified 299 MOM THR's. 59 patients reported a recent deterioration in symptoms. 67 had an abnormal x-ray. 232 hips underwent MARS MRI: 66 showed mild MOM disease, 31 moderate MOM disease, 17 severe MOM disease. 117 had a substantial fluid collection around the hip. Serum cobalt/chromium ions were raised in 135 patients. 46 had one or both above 7 ppb. 148 THR's were referred to a revision surgeon. 21 have been revised and 14 are awaiting revision. In total 64 hips have been revised. 13 were histologically proven ALVAL, 19 had clinical findings of ALVAL (not histologically confirmed), and 1 non-specific reaction to metal wear. 53 asymptomatic patients had evidence of soft tissue reaction on MRI and/or rising metal ions. Our screening programme identified asymptomatic patients with evidence of a suspicious reaction to their MOM THR. We recommend all patients with a MOM THR are fully screened for ARMD regardless of symptoms and metal ion levels


Bone & Joint Open
Vol. 1, Issue 9 | Pages 605 - 611
28 Sep 2020
McKean D Chung SL Fairhead R Bannister O Magliano M Papanikitas J Wong N Hughes R

Aims. To describe the incidence of adverse clinical outcomes related to COVID-19 infection following corticosteroid injections (CSI) during the COVID-19 pandemic. To describe the incidence of positive SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) testing, positive SARS-COV2 IgG antibody testing or positive imaging findings following CSI at our institution during the COVID-19 pandemic. Methods. A retrospective observational study was undertaken of consecutive patients who had CSI in our local hospitals between 1 February and 30June 2020. Electronic patient medical records (EPR) and radiology information system (RIS) database were reviewed. SARS-CoV-2 RT-PCR testing, SARS-COV2 IgG antibody testing, radiological investigations, patient management, and clinical outcomes were recorded. Lung findings were categorized according to the British Society of Thoracic Imaging (BSTI) guidelines. Reference was made to the incidence of lab-confirmed COVID-19 cases in our region. Results. Overall, 1,656 lab-confirmed COVID-19 cases were identified in our upper tier local authority (UTLA), a rate of 306.6 per 100,000, as of 30June 2020. A total of 504 CSI injections were performed on 443 patients between 1 February and 30June 2020. A total of 11 RT-PCR tests were performed on nine patients (2% of those who had CSI), all of which were negative for SARS-CoV-2 RNA, and five patients (1.1%) received an SARS-CoV-2 IgG antibody test, of which 2 (0.5%) were positive consistent with prior COVID-19 infection, however both patients were asymptomatic. Seven patients (1.6%) had radiological investigations for respiratory symptoms. One patient with indeterminate ground glass change was identified. Conclusion. The incidence of positive COVID-19 infection following corticosteroid injections was very low in our cohort and no adverse clinical outcomes related to COVID-19 infection following CSI were identified. Our findings are consistent with CSI likely being low risk during the COVID-19 pandemic. The results of this small observational study are supportive of the current multi-society guidelines regarding the judicious use of CSI. Cite this article: Bone Joint Open 2020;1-9:605–611


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 32 - 32
1 Jan 2016
Hasegawa M Miyamoto N Miyazaki S Wakabayashi H Sudo A
Full Access

Introduction. Pseudotumors have been reported following metal-on-metal total hip arthroplasty (THA); however, the natural history and longitudinal imaging findings of pseudotumors have yet to be fully analyzed. Our hypothesis was that pseudotumor size might change over time following metal-on-metal THA. This hypothesis was studied longitudinally using magnetic resonance imaging (MRI). Materials and Methods. Screening for pseudotumors was performed using MRI after large-diameter metal-on-metal THA. Initial MRI was conducted at a mean of 36 months postoperatively. Follow-up MRI was performed at a mean of 20 months after the detection of 24 pseudotumors in 20 asymptomatic patients. Pseudotumors were classified as cystic, solid, and mixed types. Fourteen hips were characterized as cystic type and 10 hips were defined as mixed type. There were three men and 17 women with a mean age of 63 years. Pseudotumor size was determined on MRI by manually outlining the greatest size of the mass. Serum cobalt and chromium ion levels were measured in nine patients with unilateral THA at the time of MRI. Statistical analysis was performed using the Kruskal-Wallis test and chi square test to compare age, gender, BMI, head diameter, cup inclination, cup anteversion, and pseudotumor type among changes of pseudotumor size. We compared the pseudotumor size for the three groups (increase in size, no change, decrease in size) using Kruskal-Wallis test and Mann-Whitney U test. Wilcoxon signed-rank test was used to compare median serum metal ion levels over time. A p value < 0.05 was considered significant. This study was approved by the ethics committee of our institution, and all patients provided informed consent. Results. The mean pseudotumor size changed from 729 mm. 2. to 877 mm. 2. Among the 24 hips, pseudotumors increased in size (Fig. 1) in eight (three cystic and five mixed) and decreased in size in six (four cystic and two mixed). Ten hips showed no changes in size (seven cystic and three mixed). We found no significant differences between changes of pseudotumor size and patient characteristics. The mean initial size of pseudotumor was bigger in pseudotumors with increased in size (1002 ± 309 mm. 2. ) than in those with decreased in size (542 ± 295 mm. 2. , p = 0.020) or no change (622 ± 448 mm. 2. , p = 0.041). The median cobalt ion levels at initial MRI and follow-up MRI were 2.0 µg/L and 1.8 µg/L, respectively. The median chromium ion levels at initial MRI and follow-up MRI were 2.0 µg/L and 3.1 µg/L, respectively. No significant differences were observed between the levels of either metal at initial and subsequent MRI. Conclusions. The present results suggest that pseudotumors frequently change in size in asymptomatic patients, and our hypothesis was verified. The initial size of pseudotumor was bigger in pseudotumors with increased in size than in those with decreased in size or no change. And we might predict that bigger pseudotumors would tend to increase in size


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 38 - 38
1 Apr 2019
Lazennec JY Rakover JP Rousseau MA
Full Access

INTRODUCTION. Lumbar total disc replacement (TDR) is an alternative treatment to avoid fusion related adverse events, specifically adjacent segment disease. New generation of elastomeric non-articulating devices have been developed to more effectively replicate the shock absorption and flexural stiffness of native disc. This study reports 5 years clinical and radiographic outcomes, range of motion and position of the center of rotation after a viscoelastic TDR. Material and methods. This prospective observational cohort study included 61 consecutive patients with monosegmental TDR. We selected patients with intermediate functional activity according to Baecke score. Hybrid constructs had been excluded. Only cases with complete clinical and radiological follow-up at 3, 6, 12, 24 and 60 months were included. Mean age at the time of surgery was 42.8 +7.7 years-old (27–60) and mean BMI was 24.2 kg/m² +3.4 (18–33). TDR level was L5-S1 in 39 cases and L4-L5 in 22 cases. The clinical evaluation was based on Visual Analog Scale (VAS) for pain, Oswestry Disability Index (ODI) score, Short Form-36 (SF36) including physical component summary (PCS) and mental component summary (MCS) and General Health Questionnaire GHQ28. The radiological outcomes were range of motion and position of the center of rotation at the index and the adjacent levels and the adjacent disc height changes. Results. There was a significant improvement in VAS (3.3±2.5 versus 6.6±1.7, p<0.001), in ODI (20±17.9 versus 51.2±14.6, p<0.001), GHQ28 (52.6±15.5 versus 64.2±15.6, p<0.001), SF 36 PCS (58.8±4.8 versus 32.4±3.4, p<0.001) and SF 36 MCS(60.7±6 versus 42.3±3.4, p<0.001). Additional surgeries were performed in 5 cases. 3 additional procedures were initially planified in the surgical program: one adjacent L3-L5 ligamentoplasty above a L5S1 TDR and two L5S1 TDR cases had additional laminectomies. Fusion at the index level was secondary performed in 2 L4L5 TDR cases but the secondary posterior fusion did not bring improvement. In the 56 remaining patients none experienced facet joint pain. One patient with sacroiliac pain needed local injections. Radiological outcomes were studied on 56 cases (exclusion of 5 cases with additional surgeries). The mean location centers of the index level and adjacent discs were comparable to those previously published in asymptomatic patients. According to the definition of Ziegler, all of our cases remained grade 0 for disc height (within 25% of normal). Discussion. The silent block design of LP-ESP provides an interesting specificity. It could be the key factor that makes the difference regarding facets problems and instability reported with other implants experimentally or clinically. Unfortunately no other comparative TDR series are available yet in the literature. Conclusion. This series reports significant improvement in mid-term follow up after TDR which is consistent with previously published studies but with a lower rate of revision surgery and no adjacent level disease pathologies. The radiographic assessment of the patients demonstrated the quality of functional reconstruction of the lumbar spine after LP ESP viscoelastic disc replacement


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 67 - 67
1 Jun 2018
Gonzalez Della Valle A
Full Access

Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2005 and 2014, 21 patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all-polyethylene cup was used. Pre-operative diagnosis was aseptic loosening (15 cemented and 6 uncemented). The femoral component was revised in 10 patients. Post-operative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete post-operative sciatic palsy. After a mean follow up of 47 months (13 to 128) none of the patients required re-revision of the acetabular component. One asymptomatic patient presented with aseptic loosening 9 years post-operatively. Hardware failure was not observed. All patients had radiographic signs of graft incorporation and bone remodeling. There were no dislocations. The early and mid-term results of revisions of large acetabular defects with this technique are encouraging. Reconstitution of hip center of rotation and bone stock with the use of a small-size implant makes this technique an attractive option for large defects. Longer follow-up is needed to assess survivability


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_22 | Pages 68 - 68
1 Dec 2017
Pradier M Suy F Issartel B Dehecq C Loiez C Valette M Senneville E
Full Access

Aim. Propionibacterium acnes (PA) is an important cause of shoulder prosthetic joint infections (SPJIs) for which the optimal treatment has not yet been determined. Rifampicin and Levofloxacin both showed not benefit in recent experimental models of PA-SPJIs. We describe herein the experience of five different medical French centers in order to assess factors associated with patient's outcome with special emphasize on antibiotic regimens. Method. A multicentric retrospective study was performed, on consecutive patients with PA – related SPJIs diagnosed on the basis of at least 2 or more positive cultures of either per-operative or joint aspiration and clinical history compatible with a PJI according to the current guidelines. All patients had surgical management, followed by systemic antibiotic therapy. Remission was defined as an asymptomatic patient with functioning prosthesis at the last contact. Results. Fifty-nine patients of mean age 66.2 ± 10.5 years were included. Most patients were at least ASA 2 (66%), 8 (14%) diabetes mellitus, 3 (5%) had neoplasia. Fourteen patients (24%) had acute, 34 (58%) subacute, and 11 late infections (19%). The mean delay from symptoms of infection to surgery was 89 ± 141 days (1–660). Surgical management consisted in implant exchange in 40 (68%) patients. Antibiotic treatment included mainly clindamycin (49%), levofloxacin (44%) and rifampin (17%), with a mean duration of 52.3 ± 31.9 days. The mean follow-up duration was 540 days ± 488 (range 12 ™ 1925). Forty-five patients were in remission (76%) in this study, 8 patients had a relapsing infection (14%), 1 a recurrence (2%) and 5 a superinfection ™ i.e, due to a different pathogen − (8%). In monovariate analysis, rifampicin/levofloxacin treatment was significantly associated with failure (p=0.038). In multivariate analysis, levofloxacin use and implants retention were significantly related to failure (p=0.02 and p=0.003, respectively). Conclusions. Our results suggest that implant retention and levofloxacin use are two independents factors of failure in patients treated for PA – related SPJIs


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 147 - 147
1 Feb 2017
McGrory B Hussey D
Full Access

Introduction. Mechanically assisted crevice corrosion (MACC) in metal-on-polyethylene (MOP) total hip arthroplasty (THA) is of concern, but its prevalence, etiology and natural history are incompletely understood. Methods. From January 2003 to December 2012, 1356 consecutive THA surgeries using a titanium stem, cobalt chromium alloy femoral head, highly crosslinked polyethylene and a tantalum or titanium acetabular shell were performed. Patients were followed at 1 year, and 5 year intervals for surveillance, but also seen earlier if they had symptoms. Any patient with osteolysis or unexplained pain underwent exam, radiographs, CBC, ESR and CRP, as well as serum cobalt (Co) and chromium (Cr) level. MARS MRI was performed if the Co level was > 1 ppb. Results. Symptomatic MACC was present in 39/1356 patients (2.9%). Yearly MACC prevalence ranged from 0 % (0/139, 2005) to 9.9 % (16/162, 2009). 22/39 (56%) patients have undergone revision surgery, and 17/39 (44%) have opted for ongoing surveillance. Of the surveillance patients, serial serum metal ion levels appear to increase over time. Time of symptoms is correlated with tissue necrosis at time of revision. Conclusions. The prevalence of MACC in MOP hips is higher in this cross-sectional study than previously reported. The highest prevalence was found in 2009 with this vendor. Based on how common this finding is in symptomatic patients from 2009, we may consider asking asymptomatic patients to obtain baseline serum ion levels. The goal of our ongoing research is to understand how to avoid permanent soft tissue loss from adverse local tissue reactions caused by MACC


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 62 - 62
1 Dec 2016
Della Valle AG
Full Access

Uncontained acetabular defects with loss of superior iliac and posterior column support (Paprosky 3B) represent a reconstructive challenge as the deficient bone will preclude the use of a conventional hemispherical cup. Such defects can be addressed with large metallic constructs like cages with and without allograft, custom tri-flange cups, and more recently with trabecular metal augments. An underutilised alternative is impaction bone grafting, after creating a contained cavitary defect with a reinforcement mesh. This reconstructive option delivers a large volume of bone while using a small-size socket fixed with acrylic cement. Between 2006 and 2014, sixteen patients with a Paprosky 3B acetabular defect were treated with cancellous, fresh frozen impaction grafting supported by a peripheral reinforcement mesh secured to the pelvis with screws. A cemented all polyethylene cup was used. Preoperative diagnosis was aseptic loosening (10 cemented and 6 non-cemented). The femoral component was revised in 9 patients. Postoperative course consisted of 3 months of protected weight bearing. Patients were followed clinically and radiographically. One patient had an incomplete postoperative sciatic palsy. After a mean follow up of 40 months (24 to 104) none of the patients required re-revision. One asymptomatic patient presented with aseptic loosening 9 years postoperatively. Hardware failure was not observed. All patients had radiographic signs of graft incorporation and bone remodeling. There were no dislocations. The early and mid-term results of revisions for large acetabular defects with this technique are encouraging. Reconstitution of hip center of rotation and bone stock with the use of a small-size implant make this technique an attractive option for these large defects. Longer follow-up is needed to assess survivability


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 52 - 52
1 Feb 2020
Lazennec J Kim Y Caron R Folinais D Pour AE
Full Access

Introduction. Most of studies on Total Hip Arthroplasty (THA) are focused on acetabular cup orientation. Even though the literature suggests that femoral anteversion and combined anteversion have a clinical impact on THA stability, there are not many reports on these parameters. Combined anteversion can be considered morphologically as the addition of anatomical acetabular and femoral anteversions (Anatomical Combined Anatomical Anteversion ACA). It is also possible to evaluate the Combined Functional Anteversion (CFA) generated by the relative functional position of femoral and acetabular implants while standing. This preliminary study is focused on the comparison of the anatomical and functional data in asymptomatic THA patients. Material and methods. 50 asymptomatic unilateral THA patients (21 short stems and 29 standard stems) have been enrolled. All patients underwent an EOS low dose evaluation in standing position. SterEOS software was used for the 3D measurements of cup and femur orientation. Cup anatomical anteversion (CAA) was computed as the cup anteversion in axial plane perpendicular to the Anterior Pelvic Plane. Femoral anatomical anteversion (FAA) was computed as the angle between the femoral neck axis and the posterior femoral condyles in a plane perpendicular to femoral mechanical axis. Functional anteversions for the cup (CFA) and femur (FFA) were measured in the horizontal axial patient plane in standing position. Both anatomical and functional cumulative anteversions were calculated as a sum. All 3D measures were evaluated and compared for the repeatability and reproducibility. Statistical analysis used Mann-Whitney U-test considering the non-normal distribution of data and the short number of patients (<30 for each group). Results. Functional cumulative anteversion was significantly higher than anatomical cumulative anteversion for all groups (p<0.05). No significant difference could be noted between the cases according to the use of short or standard stems. Conclusion. This study shows the difference of functional implant orientation as compared to the anatomical measurements. This preliminary study has limitations. First the limited sample of patients. Then this series only includes asymptomatic subjects. Nevertheless, this work focused on the feasibility of the measurements shows the potential interest of a functional analysis of cumulated anteversion. Standing position influences the relative position of THA implants according to the frontal and sagittal orientation of the pelvis. The relevance of these functional measurements in instability cases must be demonstrated, especially in patients with anterior subluxation in standing position which is potentially associated with pelvic adaptative extension. Further studies are needed for the feasibility of measurements on EOS images in sitting position and their analysis in case of instability. For any figures or tables, please contact authors directly