Abstract
A concern of metal on metal hip resurfacing arthroplasty is long term exposure to Cobalt (Co) and Chromium (CR) wear debris from the bearing. This study compares whole blood metal ion levels from patients drawn at one-year following Birmingham Hip Resurfacing (BHR) to levels taken at a minimum 10-year follow-up.
A retrospective chart review was conducted to identify all patients who underwent a BHR for osteoarthritis with a minimum 10-year follow-up. Whole blood metal ion levels were drawn at final follow-up in June 2019. These results were compared to values from patients with one-year metal ion levels.
Of the 211 patients who received a BHR, 71 patients (54 males and 17 females) had long term metal ion levels assessed (mean follow-up 12.7 +/− 1.4 years). The mean Co and Cr levels for patients with unilateral BHRs (43 males and 13 females) were 3.12 ± 6.31 ug/L and 2.62 ± 2.69 ug/L, respectively, and 2.78 ± 1.02 ug/L and 1.83 ± 0.65 ug/L for patients with bilateral BHRs (11 males and 4 females). Thirty-five patients (27 male and 8 female) had metal-ion levels tested at one-year postoperatively. The mean changes in Co and Cr levels were 2.29 ug/l (p = 0.0919) and 0.57 (p = 0.1612), respectively, at one year compared to long-term. These changes were not statistically significant.
This study reveals that whole blood metal ion levels do not change significantly when comparing one-year and ten-year Co and Cr levels. These ion levels appear to reach a steady state at one year.
Our results also suggest that regular metal-ion testing as per current Medicines and Healthcare products Regulatory Agency (MHRA) guidelines may be impractical for asymptomatic patients. Metal-ion levels, in and of themselves, may in fact possess little utility in determining the risk of failure and should be paired with radiographic and clinical findings to determine the need for revision.