Cemented total hip arthroplasty yields reliable results in short to medium term studies, but aseptic loosening remains a problem in long-term follow up, especially in young and active patients. Aseptic loosening has been related to wear, and in order to minimize wear various alternatives to the traditional metal on polyethylene have been proposed. Both ceramic on polyethylene (COP) and metal on metal (MOM) have been shown to produce less wear than metal on polyethylene (MOP). In order to study the effect of the bearing, we have utilized identical stems and cups while comparing the different bearings. Methods and material. 396 hips were randomized to MOP, COP or MOM using a cemented triple tapered polished stem (MS-30; Sulzer Orthopedics) with a cemented polyethylene cup (Weber; Sulzer, Orthopedics) and a 28 millimeter head. For the MOP and COP articulations, a all-polyethylene cup was used with a Protasul™ metal head or a Sulox™ alumina head, whereas a polyethylene cup with metal insert was used for the MOM articulations (Weber Polyethylene Cup with Metasul™ Insert) with a Metasul™ metal head. Harris Hip Score (HHS) and radiological evaluation was performed after two, five and seven years. Ethical approval was obtained. Results. HHS was available for 338 hips after seven years. The HHS in the MOP group (116 hips) was 93.7 (SD 9.0), 93.5 in the COP group (112 hips) (SD 8.8), and 91.0 (SD 13.4) in the MOM group (110 hips). Radiographic evaluation was available for 335 hips. Radiolucencies around the stem larger than one millimeter were found in five of 115 MOP hips, seven of 111 COP hips and in seven of 110 MOM hips. Periacetabular radiolucencies identified as larger than one millimeter were found in none of the 116 MOP hips, five of the 112 COP hips and in 19 of the 110 MOM hips. Ten revisions were performed. In the MOP group there were three revisions (infection, dislocation, pain); one in the COM group (infection), and six in the MOM group (three infections, two aseptic loosening and one septic loosening). Discussion. Clinically, the three bearing types perform equally well at seven years, and there are few signs of impending failure for the stem. However, there are an alarmingly high proportion of cups showing signs of loosening. Two hips have been revised in the MOM group for aseptic loosening as opposed to none in the two other groups, which adds to the concern. The MOM articulation used in this study should be monitored closely for signs of aseptic loosening


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 223 - 223
1 Sep 2012
Herrera L Loving L Essner A Nevelos J
Full Access

Osteolysis induced by UHMWPE debris has historically been one of the major causes of long term failure of TJR. An increase in concentration of polyethylene particles in the peri-prostheic tissue has been linked to an increased incidence of osteolysis. The dual mobility hip bearing concept mates a femoral head into a polyethylene liner which has an unconstrained articulation into a metal shell. The wear mechanism of the dual mobility hip bearing is distinct from a constrained single articulation design, which may result in a difference in wear debris particles. The aim of this study is to evaluate wear debris generated from a dual mobility hip and compare it to a conventional single articulation design when both are manufactured from sequentially crosslinked and annealed polyethylene. The dual mobility hip (Restoration ADM) incorporated a 28mm CoCr femoral head into a polyethylene liner that articulates against a metal shell (48mm ID). The conventional hip (Trident®) mated a 28mm CoCr femoral head against a polyethylene liner. The polyethylene for all liners was sequentially crosslinked and annealed (X3). A hip joint simulator was used for testing at a rate of 1 Hz with cyclic Paul curve physiologic loading. A serum sample from each testing group was collected. Serum samples were protein digested following the published process by Scott et al. The digested serum was then filtered through a series of polycarbonate filter papers of decreasing size and sputter coated with gold for analysis using SEM. Image fields were randomized and wear debris was compared in terms of its length, width, aspect ration, and equivalent circular diameter (ECD). A total of 149 conventional hip particles and 114 dual mobility hip particles were imaged. Results show a majority of particles are of spherical nature and images do not indicate the presence of fibrillar or larger elongated polyethylene debris. Particle length between designs is not statistically different, while all other comparisons show statistical significance (p<0.05). It is hypothesized that the dual mobility hip system reduces the total amount of cross-shear motion on any one articulation, which aids in the reduction in wear. This design feature may be responsible for the slight difference in morphology of dual mobility wear debris when compared to the constrained hip design. The length of the particles was similar, simply indicating a different shape rather than a marked reduction in overall size. The debris generated is this study was from highly crosslinked polyethylene in two different designs, which produced a very significant decrease in quantity of particles when compared to the quantity of debris from conventional polyethylene. The wear debris was of similar length in both designs and so we do not expect any difference in biological response to debris from either device. The dual mobility design has also shown no effect of cup abduction angle on wear demonstrating forgiveness to implant positioning. This advantage, combined with the low wear rate and similar length wear particles, should lead to good clinical performance of dual mobility cups with sequentially irradiated and annealed polyethylene


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_8 | Pages 6 - 6
1 May 2018
Abdelhaq A Walker E Sanghrajka A
Full Access

Background. Disruption of the normal relationship between the proximal tibia and fibula is seen in a number of different conditions such as skeletal dysplasias and post-infective deformity, as well as the consequence of lengthening procedures. Radiographic indices for the tibio-fibular relationship at the ankle have been described, but no similar measures have been reported for the proximal articulation. Aim. The purpose of this study was to investigate the normal radiographic relationship between the proximal tibia and fibula in children to determine the normal range and variation. Methods. Our radiology database was used to identify a sample of 500 normal anteroposterior radiographs of paediatric knees. All radiographs were reviewed by a single observer. The distance from the corner of the lateral tibial plateau to both the proximal tibial (PT) and fibular physes (PF) were measured, and a ratio of the two calculated (PF/PT). The process was repeated with a sample of 100 radiographs by the same observer, and a second independent observer in order to calculate intra-and inter-observer reliability. Results. The age range of patients in this study was 4–16 years, with mean age 12.7. The mean PF/PT ratio was 1.7 (standard deviation 0.2, range 1.3–2.0). Intra-observer reliability was 100% and inter-observer reliability was 97.8%. Conclusion. The results of this study demonstrate that in the normal paediatric knee, there is a consistent relationship between the position of the proximal tibial and fibular physes, with a small range of variation. The PF/PT ratio is a simple and reliable way of assessing the relationship between the proximal tibia and fibula in children, using a standard anteroposterior radiograph. This ratio could be very useful in the diagnosis and planning of surgical management of a number of different causes of tibial and fibular deformities in children


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 185 - 185
1 Sep 2012
Von Knoch F Neuerburg C Impellizzeri F Goldhahn J Frey P Naal F Von Knoch M Leunig M
Full Access

Background. Second-generation high-carbon CoCrMo-alloy metal-on-metal total hip arthroplasty (THA) was introduced in the late 1980s following reports of early loosening, impingement, pronounced wear, and hypersensitivity in the first-generation metal-on-metal articulations. There has been inconsistent data that specifically addresses the clinical performance and longevity of second-generation metal-on-metal THA. The purpose of this study was to evaluate the survival of second-generation metal-on-metal primary THA and to assess the influence of demographic factors on implant survival in a large patient cohort. Methods. One thousand two hundred and seventy second-generation 28 mm metal-on-metal primary THA in 1121 patients were performed at one institution from 1994 to 2004. According to the International Documentation and Evaluation System patients were followed routinely at one year, two years and every five years thereafter. Clinical and radiographic outcome data was prospectively recorded using a hospital joint registry. At a mean follow-up of 6.8 years postoperatively, the probability of survival of THA was estimated using the method of Kaplan and Meier. Relative risk factors for implant failure that included age, gender, BMI, type of implant fixation and size of implant components were calculated using the Cox proportional-hazards model. Results. Sixty three (5%) hips were revised because of aseptic loosening (28 hips), infection (8 hips), periprosthetic fracture (8 hips), recurrent dislocation (8 hips), pain without implant loosening (7 hips) and breakage of the cup (4 hips). The probability of survival at ten years, with revision for any reason as the endpoint, for the THA as a whole was 0.90 (95% confidence interval, 0.87 to 0.94). The probability of survival for the cup was 0.90 (95% confidence interval, 0.86 to 0.93) and for the stem 0.94 (95% confidence interval, 0.91 to 0.97). No demographic factors or covariates were found to significantly affect survivorship. Conclusion. Second-generation metal-on-metal primary THA did not demonstrate a superior probability of survival at ten years compared with previous reports on other weight-bearing surfaces. Based on these findings and with consideration of concerns that relate to putative local and systemic toxicity of metal debris, the use of second-generation metal-on-metal articulations for primary THA remains moot


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 94 - 94
1 Sep 2012
Penny J Varmarken J Ovesen O Nielsen C Overgaard S
Full Access

Introduction. Metal on metal articulations produce chromium (Cr) and cobalt (Co) debris, particularly when the articulations are worn in. High levels in the peripheral blood are indicative of excess wear and may cause adverse effects. The present RCT investigates metal ion levels and the relationship of Co, Cr ions and lymphocyte counts during the running-in period. Materials and Methods. Following randomization to RHA (ASRTM, DePuy) or THA we obtained whole blood (wb), and serum (s) samples at baseline, 8 w, 6 m and 1 y. We measured the Co and Cr concentrations, the total lymphocyte count as well as the CD3+, CD4+, CD8+, CD19+ and CD16+/CD56+ sub populations. Cup inclination and anteversion angles came from conventional radiographs. Activity was measured as steps by pedometer and UCLA activity. Data are presented as median (range). Results. We had 19 patients in each group. Age 57 (46–64) y (RHA) and 55 (44–64) y (THA). RHA only: head size: 51 (47 to 57)mm, cup inclination: 45.0 (40- 56)° and anteversion: 23 (7–38)°. The ion concentrations stayed below 0.2 ppb for THAs. For RHAs the Co and Cr concentrations generally rose markedly in the initial 8 weeks, followed by a slower ascent up to 1 year to wb Co: 1.0 (0.6–5.2), s Co: 1.3 (0.7–6.5), wb Cr: 1.3 (0.4–8.0) and s Cr: 1.7 (0.6–15) ppb. A high ion level was correlated to a small head size (p<0.03) and a cup inclination around 45° (p<0.04). We could not correlate the ion concentrations to the anteversion or the activity levels. The absolute lymphocyte counts were not always identical in the groups (eg. lower CD8+ for RHA) but there was no group difference when we analysed the change from baseline. We did not demonstrate any correlation between metal ion levels and lymphocyte subpopulations. Discussion. The findings of this study does not support the theory that metal ions suppress the lymphocytes or the CD8+ in particular (Hart et al., 2009). Our conclusions are limited by low numbers, but we suspect the theory could be biased by missing baseline values. Our study did not demonstrate the same 6–9 months ion peak found in other running-in studies (Back et al., 2005, Heisel et al., 2008), but rather a slow continuous rise with lower median ion concentrations. It could indicate lower wear or perhaps a longer running in period in our slightly older population. Contrary to our expectations we found that cups placed in optimal inclination displayed a higher ion level. Most of the smallest cups were found in this group, and the majority of the steep cups had very large heads. For this implant head size may be more important than cup position


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 578 - 578
1 Sep 2012
Grammatopoulos G Judge A Pandit H Mclardy-Smith P Glyn-Jones S Desmet K Murray D Gill H
Full Access

INTRODUCTION. Although simulation studies have shown superior wear properties of metal-on-metal articulations, increased concern exists regarding the excess in-vivo wear of a small number of Metal-on-Metal-Hip-Resurfacing (MoMHRA) implants. Serum ion levels of Chromium (Cr) and Cobalt (Co) are surrogate markers of wear. Risk factors associated with increased wear include female gender, small components, dysplasia, cup orientation outside safe zone and femoral head downsize during surgery with an associated decrease in Head-Neck-Ratio (HNR). However, these factors are interlinked. This study aims to identify the factors that are most important for subsequent wear of MoMHRA, by performing a multivariate analysis. METHODS. 206 patients (124M: 82F) with unilateral MoMHRA were included in this study. The average follow up was 3.3 years. All patients had Cr/Co levels measured at follow up. Inclination and anteversion of each cup were measured using EBRA. Cups were analysed as being within or outside the previously defined optimum-zone. HNR measurements were made from pre-operative (HNRpre) and post-operative (HNRpost) radiographs. The immediate changes in HNR (downsize/upsize of femoral head) as a result of the operation were expressed as:. HNRprepost=HNRpost–HNRpre. Multivariate linear regression modelling was used to explore the association between measures of ions with the following predictor variables (gender, age, diagnosis, femoral component size, orientation of the acetabular component, head/neck ratio and position of femoral stem). Analyses were carried out separately for each outcome (Cr and Co). Classification and Regression Tree (CART) models were fitted as a complimentary approach to regression modelling. RESULTS. Articular surface downsize followed by cup orientation within/outside optimum zone, followed by cup anteversion followed by gender were the strongest predictors of ion levels. A percentage decrease in HNRartpost, predicted an increase in Cr ion level by 5% (and 6% for Co). If the cup was within the optimum zone this was associated with decreased levels of Cr and Co ions. As acetabular component anteversion increased, levels of ions increased. Gender had a strong effect on ion levels. Adjusting for other variables, the effect of gender was attenuated due to a confounding effect of component size and the amount of femoral head downsize. Predictors identified as important in regression analyses were similar to those produced in the CART model, where the highest levels of ions were seen in patients with a percentage decrease in pre-operative HNR −11.3. DISCUSSION. This analysis shows that (surgical) factors, such as amount of femoral head downsize at operation and whether the cup was orientated within the optimum zone, explained the majority of the variability in ion levels in MoMHRA


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 2 | Pages 244 - 249
1 Mar 1996
Judet T de Loubresse CG Piriou P Charnley G

We report our experience over seven years with a floating radial-head prosthesis for acute fractures of the radial head and the complications which may result from such injury. The prosthesis has an integrated articulation which allows change of position during movement of the elbow. We present the results in 12 patients with a minimum follow-up of two years. Five prostheses had been implanted shortly after injury with an average follow-up of 49 months and seven for the treatment of sequelae with an average follow-up of 43 months. All prostheses have performed well with an improved functional score (modified from Broberg and Morrey 1986). We have not experienced any of the complications previously reported with silicone radial-head replacement. Our initial results suggest that the prosthesis may be suitable for the early or delayed treatment of Mason type-III fractures and more complex injuries involving the radial head


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 341 - 341
1 Sep 2012
Bernstein M Desy N Huk O Zukor D Petit A Antoniou J
Full Access

Introduction. Metal-on-metal (MoM) articulations in total hip replacement (THR) have become an attractive option for young, active patients. Short-term reports have demonstrated elevated systemic metal ion levels in the blood and urine. Disseminated concentrations of cobalt and chromium have raised concern regarding cellular toxicity, chromosomal damage and adverse local soft tissue reactions. Long-term studies are required to support the increased use of MoM bearings in younger patients given their potential deleterious effects. The purpose of the current study was to report the 7–13 year clinical, radiographic, and metal ion results in patients following MoM THR. Methods. We prospectively followed 165 patients (196 hips) after second-generation MoM THR between July 1997 and November 2003. Functional outcome was measured using the Harris Hip Score (HHS) and the University of California Los Angeles (UCLA) Activity Score. Radiographic analysis was performed using Einzel-Bild-Roentgen-Analyse (EBRA) by two of the authors blinded to the study. Cobalt and chromium metal ions were measured from whole blood and analyzed using inductively coupled plasma-mass spectrometry. Results. 163 prostheses were analyzed. The mean age at surgery was 50.8 years (range, 17 to 66). There were 80 females and 83 males. The mean follow-up was 8.87 years (range, 7–13 years). Four hips (2.5%) were revised: 2 for infection at 0.2 and 7 years; 1 for a loose stem at 1.3 years; and 1 for a loose cup at 9 years. One patient received wound debridement for a superficial infection and did not have any components revised. The mean HHS and UCLA scores at the last follow-up were 91 and 6.8, respectively. The mean acetabular inclination and anteversion was 40 degrees (range, 24 to 57), and 19 degrees (range, 3 to 39), respectively. Median cobalt levels peaked at a value of 2.87 μg/L at 4 years (p<0.0001 vs. pre-operative) and subsequently decreased to 2.0 μg/L after 9 years (p=0.002 vs. 4-years). Median chromium levels maximally increased up to 0.75 μg/L after 5 years (p<0.0001 vs. pre-operative) and tended to decrease thereafter to values of 0.56 μg/L after 7 years. The Kaplan-Meier survivorship was 91.3% for revision for all causes, and 97.5% when excluding the hips revised for a manufacturer's defect at a mean of 8.87 years (range, 7–13 years). Conclusion. The present 7–13 years follow-up study of MoM THRs indicates that the clinical and radiological results are satisfactory with low revision rates. Furthermore, our study demonstrates the trend of metal ion levels in whole blood over a long-term. Both cobalt and chromium ion levels peaked at 4 and 5 years, respectively, and gradually decreased thereafter


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 177 - 177
1 Sep 2012
Christofilopoulos P Lübbeke A Berton C Lädermann A Berli M Roussos C Peter R Hoffmeyer P
Full Access

Introduction. Large diameter metal on metal cups have been used in total hip arthroplasty advocating superior results with respect to dislocation rates, range of motion and long term survival. The Durom cup used as part of the Durom hip resurfacing system has been incriminated with poor short term results sometimes correlated to incorrect positioning of either the femoral or acetabular component. Our objective was to evaluate short term results of the Durom cup used in conjunction with standard stems. Methods. We prospectively followed all patients with a large diameter metal-on-metal articulation (Durom) and a standard stem operated upon between 9/2004 and 9/2008. Patients were seen at follow-up for a clinical (Harris hip score=HHS, UCLA scale and patient satisfaction), radiographic and questionnaire assessment. Results. 89 primary THAs in 80 patients (74% men) with a mean age of 52 (±12) years were included. Main diagnoses were primary osteoarthritis in 47% and aseptic necrosis in 35%. An uncemented stem was used in 79%. Overall, 80 THAs were controlled at a mean follow-up of 39 months (range 16–67 months), 4 patients were lost to follow-up and 5 patients refused or were unable to attend the visit. However, none of the 5 underwent revision. Overall, 8 THAs (8/85, 9.4%) were revised in mean 28 months (range 8–60) after the operation. One additional patient was awaiting revision for aseptic loosening of both cup and stem. The reasons for revision were aseptic loosening in three cases, presence of a granuloma (histological diagnosis of ALVAL) in three, deep infection in one and impingement in one case. Radiographic analysis revealed linear (n=2) and focal (n=3) osteolysis as well as early cup migration (n=2). In 5 revised patients no radiographic changes were found. 56 (70%) of the 80 patients with follow-up had a HHS between 80 and 100. Among those who were not revised, the mean HHS improved from 55.2 to 88.4 (mean increase 33.2, 95% CI 27.7; 38.7). The mean activity level (UCLA scale) at follow-up was 6.4 (±1.8). Overall, mild to severe pain was reported in 14 cases and occasional pain in 22. Groin pain was present in 18 patients (22.5%), 7 of them belonged to the revised group. 61 (76.3%) of the 80 patients with follow-up were satisfied. Mean patient satisfaction on the VAS scale among those who were not revised was 9.0 (±1.3). Conclusion. This study confirms the increased short-term revision rate of the large diameter metal-on-metal couple (Durom) reported by others. In all revision cases the retrieved cups showed no osteo-integration and were removed easily. The operative indication for revision was based upon groin pain and patient dissatisfaction. Radiographic signs of implant loosening were not always present even though in all revised cases except for one the cup was found loose


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 1003 - 1008
1 Jul 2016
Fenton P Al-Nammari S Blundell C Davies M

Aims

Although infrequent, a fracture of the cuboid can lead to significant disruption of the integrity of the midfoot and its function. The purpose of this study was to classify the pattern of fractures of the cuboid, relate them to the mechanism of injury and suggest methods of managing them.

Patients and Methods

We performed a retrospective review of patients with radiologically reported cuboid fractures. Fractures were grouped according to commonly occurring patterns of injury. A total of 192 fractures in 188 patients were included. They were classified into five patterns of injury.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 427 - 435
1 Sep 2016
Stravinskas M Horstmann P Ferguson J Hettwer W Nilsson M Tarasevicius S Petersen MM McNally MA Lidgren L

Objectives

Deep bone and joint infections (DBJI) are directly intertwined with health, demographic change towards an elderly population, and wellbeing.

The elderly human population is more prone to acquire infections, and the consequences such as pain, reduced quality of life, morbidity, absence from work and premature retirement due to disability place significant burdens on already strained healthcare systems and societal budgets.

DBJIs are less responsive to systemic antibiotics because of poor vascular perfusion in necrotic bone, large bone defects and persistent biofilm-based infection. Emerging bacterial resistance poses a major threat and new innovative treatment modalities are urgently needed to curb its current trajectory.

Materials and Methods

We present a new biphasic ceramic bone substitute consisting of hydroxyapatite and calcium sulphate for local antibiotic delivery in combination with bone regeneration. Gentamicin release was measured in four setups: 1) in vitro elution in Ringer’s solution; 2) local elution in patients treated for trochanteric hip fractures or uncemented hip revisions; 3) local elution in patients treated with a bone tumour resection; and 4) local elution in patients treated surgically for chronic corticomedullary osteomyelitis.


The Bone & Joint Journal
Vol. 95-B, Issue 2 | Pages 151 - 159
1 Feb 2013
Duckworth AD McQueen MM Ring D

Most fractures of the radial head are stable undisplaced or minimally displaced partial fractures without an associated fracture of the elbow or forearm or ligament injury, where stiffness following non-operative management is the primary concern. Displaced unstable fractures of the radial head are usually associated with other fractures or ligament injuries, and restoration of radiocapitellar contact by reconstruction or prosthetic replacement of the fractured head is necessary to prevent subluxation or dislocation of the elbow and forearm. In fractures with three or fewer fragments (two articular fragments and the neck) and little or no metaphyseal comminution, open reduction and internal fixation may give good results. However, fragmented unstable fractures of the radial head are prone to early failure of fixation and nonunion when fixed. Excision of the radial head is associated with good long-term results, but in patients with instability of the elbow or forearm, prosthetic replacement is preferred.

This review considers the characteristics of stable and unstable fractures of the radial head, as well as discussing the debatable aspects of management, in light of the current best evidence.

Cite this article: Bone Joint J 2013;95-B:151–9.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 3 | Pages 354 - 360
1 Mar 2007
Konrad GG Kundel K Kreuz PC Oberst M Sudkamp NP

The objective of this retrospective study was to correlate the Bado and Jupiter classifications with long-term results after operative treatment of Monteggia fractures in adults and to determine prognostic factors for functional outcome. Of 63 adult patients who sustained a Monteggia fracture in a ten-year period, 47 were available for follow-up after a mean time of 8.4 years (5 to 14). According to the Broberg and Morrey elbow scale, 22 patients (47%) had excellent, 12 (26%) good, nine (19%) fair and four (8%) poor results at the last follow-up. A total of 12 patients (26%) needed a second operation within 12 months of the initial operation. The mean Broberg and Morrey score was 87.2 (45 to 100) and the mean DASH score was 17.4 (0 to 70). There was a significant correlation between the two scores (p = 0.01). The following factors were found to be correlated with a poor clinical outcome: Bado type II fracture, Jupiter type IIa fracture, fracture of the radial head, coronoid fracture, and complications requiring further surgery.

Bado type II Monteggia fractures, and within this group, Jupiter type IIa fractures, are frequently associated with fractures of the radial head and the coronoid process, and should be considered as negative prognostic factors for functional long-term outcome. Patients with these types of fracture should be informed about the potential risk of functional deficits and the possible need for further surgery.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1493 - 1498
1 Nov 2009
Genet F Marmorat J Lautridou C Schnitzler A Mailhan L Denormandie P

Heterotopic ossification (HO) of the hip after injury to the central nervous system can lead to joint ankylosis. Surgery is usually delayed to avoid recurrence, even if the functional status is affected. We report a consecutive series of patients with HO of the hip after injury to the central nervous system who required surgery in a single, specialised tertiary referral unit. As was usual practice, they all underwent CT to determine the location of the HO and to evaluate the density of the femoral head and articular surface. The outcome of surgery was correlated with the pre-, peri- and post-operative findings.

In all, 183 hips (143 patients) were included of which 70 were ankylosed. A total of 25 peri-operative fractures of the femoral neck occurred, all of which arose in patients with ankylosed hips and were associated with intra-articular lesions in 18 and severe osteopenia of the femoral head in seven. All the intra-articular lesions were predicted by CT and strongly associated with post-operative complications.

The loss of the range of movement before ankylosis is a more important factor than the maturity of the HO in deciding the timing of surgery. Early surgical intervention minimises the development of intra-articular pathology, osteoporosis and the resultant complications without increasing the risk of recurrence of HO.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 1 | Pages 91 - 96
1 Jan 2009
Labbe J Peres O Leclair O Goulon R Scemama P Jourdel F

We have reviewed our experience in managing 11 patients who sustained an indirect sternal fracture in combination with an upper thoracic spinal injury between 2003 and 2006. These fractures have previously been described as ‘associated’ fractures, but since the upper thorax is an anatomical entity composed of the upper thoracic spine, ribs and sternum joined together, we feel that the term ‘fractures of the upper transthoracic cage’ is a better description. These injuries are a challenge because they are unusual and easily overlooked. They require a systematic clinical and radiological examination to identify both lesions. This high-energy trauma gives severe devastating concomitant injuries and CT with contrast and reconstruction is essential after resuscitation to confirm the presence of all the lesions. The injury level occurs principally at T4–T5 and at the manubriosternal joint. These unstable fractures need early posterior stabilisation and fusion or, if treated conservatively, a very close follow-up.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1634 - 1641
1 Dec 2006
Stulik J Stehlik J Rysavy M Wozniak A

We describe the results of 287 intra-articular fractures of the calcaneum in 247 patients treated by minimally-invasive reduction and K-wire fixation between 1994 and 2003. There were 210 men (85%) and 37 women (15%). The most common cause of injury was a fall from a height in 237 patients (96%). Fracture classification was based on the method described by Sanders and Essex-Lopresti. All patients were operated on within 21 days of injury and 89% (220) within 48 hours. The reduction was graded as nearly anatomical (less than 2 mm residual articular displacement and satisfactory overall alignment) in 212 (73.9%) fractures.

There were 20 cases (7%) of superficial pin-track infection and five (1.7%) of deep infection. All healed at a mean of 6 weeks (3 to 19). Loss of reduction was observed in 13 fractures (4.5%) and a musculocutaneous flap was needed in three (1%).

The results were evaluated in 176 patients (205 fractures) with a mean age of 44.3 years (13 to 67), available for follow-up at a mean of 43.4 months (25 to 87) using the Creighton-Nebraska Health Foundation Assessment score. The mean score was 83.9 points (63 to 100). There were 29 (16.5%) excellent, 98 (55.7%) good, 26 (14.8%) fair and 23 (13%) poor results. A total of 130 patients (73.9%) were able to return to their original occupation at a mean of 5.6 months (3.2 to 12.5) after the injury.

Semi-open reduction and percutaneous fixation is an effective treatment for displaced intra-articular fractures of the calcaneum.