Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 35 - 35
7 Nov 2023
Tsang J Epstein G Ferreira N
Full Access

The Cierny and Mader classification assists with decision-making in the management of osteomyelitis by strafying the host status and the pathoanatomy of disease. However the anatomical type IV represents a heterogenous group with regards to treatment requirements and outcomes. We propose that modification of the Cierny and Mader anatomical classification with an additional type V classifier (diffuse corticomedullary involvement with an associated critical bone defect) will allow more accurate stratification of patients and tailoring of treatment strategies. A retrospective review of 83 patients undergoing treatment for Cierny and Mader anatomical type IV osteomyelitis of the appendicular skeleton at a single centre was performed. Risk factors for the presence of a critical bone defect were female patients (OR 3.1 (95% CI 1.08– 8.92)) and requirement for soft tissue reconstruction (OR 3.35 (95% CI 1.35–8.31)); osteomyelitis of the femur was negatively associated with the presence of a critical bone defect (OR 0.13 (95% CI 0.03–0.66)). There was no statistical significant risk of adverse outcomes (failure to eradicate infection or achieve bone union) associated with the presence of a critical-sized bone defect. The median time to bone union was ten months (95% CI 7.9–12.1 months). There was a statistically significant difference in the median time to bone union between cases with a critical bone defect (12.0 months (95% 10.2–13.7 months)) and those without (6.0 months (95% CI 4.8–7.1 months)). This study provided evidence to support the introduction of a new subgroup of the Cierny and Mader anatomical classification (Type V). Using a standardised approach to management, comparable early outcomes can be achieved in patients with Cierny and Mader anatomical type V osteomyelitis. However, to achieve a successful outcome, there is a requirement for additional bone and soft tissue reconstruction procedures with an associated increase in treatment time


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_5 | Pages 2 - 2
23 Apr 2024
Tsang SJ Epstein G Ferreira N
Full Access

Introduction. The Cierny and Mader classification assists with decision-making by stratifying host status and the pathoanatomy of the disease. However, the anatomical type IV represents a heterogenous group with regards to treatment requirements and outcomes. We propose that modification of the Cierny and Mader anatomical classification with an additional type V classifier (diffuse corticomedullary involvement with an associated critical bone defect) will allow more accurate stratification of patients and tailoring of treatment strategies. Materials & Methods. A retrospective review of 83 patients undergoing treatment for Cierny and Mader anatomical type IV osteomyelitis of the appendicular skeleton at a single centre was performed. Results. Risk factors for the presence of a critical bone defect were female patients (OR 3.1 (95% CI 1.08–8.92)) and requirement for soft tissue reconstruction (OR 3.35 (95% CI 1.35–8.31)); osteomyelitis of the femur was negatively associated with the presence of a critical bone defect (OR 0.13 (95% CI 0.03–0.66)). There was no statistically significant risk of adverse outcomes (failure to eradicate infection or achieve bone union) associated with the presence of a critical-sized bone defect. The median time to bone union was ten months (95% CI 7.9–12.1 months). There was a statistically significant difference in the median time to bone union between cases with a critical bone defect (12.0 months (95% 10.2–13.7 months)) and those without (6.0 months (95% CI 4.8–7.1 months)). Conclusions. This study provided evidence to support the introduction of a new subgroup of the Cierny and Mader anatomical classification (Type V). Using a standardised approach to management, comparable early outcomes can be achieved in patients with Cierny and Mader anatomical type V osteomyelitis. However, to achieve a successful outcome, there is a requirement for additional bone and soft tissue reconstruction procedures with an associated increase in treatment time


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 38 - 38
23 Feb 2023
Ernstbrunner L Almond M Rupasinghe H Jo O Zbeda R Ackland D Ek E
Full Access

The extracortical single-button (SB) inlay repair is one of the most preferred distal biceps tendon repair techniques. However, specific complications such as neurovascular injury and non-anatomic repairs have led to the development of techniques that utilize intracortical double-button (DB) fixation. To compare the biomechanical stability of the extracortical SB repair with the anatomical DB repair technique. Controlled laboratory study. The distal biceps tendon was transected in 18 cadaveric elbows from 9 donors. One elbow of each donor was randomly assigned to the extracortical SBor anatomical DB group. Both groups were cyclically loaded with 60N over 1000 cycles between 90° of flexion and full extension. The elbow was then fixed in 90° of flexion and the repair construct loaded to failure. Gap-formation and construct stiffness during cyclic loading, and ultimate load to failure was analysed. After 1000 cycles, the anatomical DB technique compared with the extracortical SB technique showed significantly less gap-formation (mean difference 1.2 mm; p=0.017) and significantly more construct stiffness (mean difference 31 N/mm; p=0.023). Ultimate load to failure was not significantly different comparing both groups (SB, 277 N ±92 vs. DB, 285 N ±135; p=0.859). The failure mode in the anatomical DB group was significantly different compared with the extracortical SB technique (p=0.002) and was due to fracture avulsion of the BicepsButton in 7 out of 9 specimens (vs. none in SB group). Our study shows that the intracortical DB technique produces equivalent or superior biomechanical performance to the SB technique. The DB repair technique reduces the risk of nerve injury and better restores the anatomical footprint of biceps tendon. The DB technique may offer a clinically viable alternative to the SB repair technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 94 - 94
1 Feb 2020
Ta M Nachtrab J LaCour M Komistek R
Full Access

Introduction. Obtaining accurate anatomical landmarks may lead to a better morphologic understanding, but this is challenging due to the variation of bony geometries. A manual approach, non-ideal for surgeons or engineers, requires a CT or MRI scan, and landmarks must be chosen based on the 3D representation of the scanned data. Ideally, anatomical landmarking is achieved using either a statistical shape model or template matching. Statistical modeling approaches require multitude of training data to capture population variation. Prediction of anatomical landmarks through template matching techniques has also been extensively investigated. These techniques are based on the minimization or maximization of an objective or cost function. As is the nature of non-rigid algorithms, these techniques can fail in the local maxima if the template and new bone models have noise or outliers. Therefore, a combination of rigid and non-rigid registration techniques is needed, in order to obtain accurate anatomical landmarks and improve the prediction process. Objective. The objective of this study was to find a way to efficiently obtain accurate anatomical landmarks based on an existing template's landmarks for use in a forward solution model (FSM) to predict patient specific mechanics. Methods. Initially, the 3D meshes for a template bone and new bone of question are imported into the FSM. Landmarks on the template are also loaded with imported data. Then, the template and new bones are located at arbitrary positions within the global coordinate system. If determined to be placed at significantly different positions, the user will re-align the bones to ensure that they are close enough for the process to commence. After initially aligning the bones, the new bone model will appear closer to the template. The template bone model is then registered to the new model using Iterative Closest Point (ICP) with scaling to find the initial regions of correspondence. For each anatomical landmark on the template, initial corresponding landmarks on the new bone are defined as being its closest point. To refine landmarks on the new bone, local corresponding regions are determined between the template and new bone models. Local corresponding regions on the template and new bone models are then registered again using ICP with a scaling algorithm to refine the landmark locations on the new model as seen in Figure 1. Results. Regardless of differences in size, geometry, and initial position, the algorithm has proven to be successful in transferring landmarks from the template bone to the new bone model (Figure 2). The results also revealed that predicted landmarks on the new bone (purple) are properly defined with respect to the landmarks on the template bone (green) (Figure 2). This process allows for the FSM to be parametric in nature for patient specific analyses. Discussion and Conclusion. The FSM successfully transferred anatomical landmarks from a template to a new bone model. It has also been proven to work on more than just the femur and pelvis. Future investigations using this process for surgical planning/implant sizing will be used for both our hip and knee FSMs. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study. With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 33 - 33
1 Apr 2019
Bandi M Siggelkow E Oswald A Parratte S Benazzo F
Full Access

Introduction. Partial knee arthroplasty (PKA) has demonstrated the potential to improve patient satisfaction over total knee arthroplasty. It is however perceived as a more challenging procedure that requires precise adaptation to the complex mechanics of the knee. A recently developed PKA system aims to address these challenges by anatomical, compartment specific shapes and fine-tuned mechanical instrumentation. We investigated how closely this PKA system replicates the balance and kinematics of the intact knee. Materials and Methods. Eight post-mortem human knee specimens (age: 55±11 years, BMI: 23±5, 4 male, 4 female) underwent full leg CT scanning and comprehensive robotic (KUKA KR140 comp) assessments of tibiofemoral and patellofemoral kinematics. Specimens were tested in the intact state and after fixed bearing medial PKA. Implantations were performed by two experienced surgeons. Assessments included laxity testing (anterior-posterior: ±100 N, medial-lateral: ±100 N, internal-external: ±3 Nm, varus- valgus: ±12 Nm) under 2 compressive loads (44 N, 500 N) at 7 flexion angles and simulations of level walking, lunge and stair descent based on in-vivo loading profiles. Kinematics were tracked robotically and optically (OptiTrack) and represented by the femoral flexion facet center (FFC) motions. Similarity between intact and operated curves was expressed by the root mean square of deviations (RMSD) along the curves. Group data were summarized by average and standard deviation and compared using the paired Student's T-test (α = 0.05). Results. During the varus-valgus balancing assessment the medial and lateral opening of the PKAs closely resembled the intact openings across the full arch of flexion, with RMSD values of 1.0±0.5 mm and 0.4±0.2 mm respectively. The medial opening was nearly constant across flexion, its average was not statistically different between intact (3.8±1.0 mm) and PKA (4.0±1.1 mm) (p=0.49). Antero-posterior envelope of motion assessments revealed a close match between the intact and PKA group for both compression levels. Net rollback was not statistically different, either under low compression (intact: 10.9±1.5 mm, PKA: 10.7±1.2, p=0.64) or under high compression (intact: 13.2±2.3 mm, PKA: 13.0±1.6 mm, p=0.77). Similarly, average laxity was not statistically different, either under low (intact: 7.7±3.2 mm, PKA: 8.6±2.5 mm, p=0.09) or under high (intact: 7.2±2.6 mm, PKA: 7.8±2.2 mm, p=0.08) compression. Activities of daily living exhibited a close match in the anterior-posterior motion profile of the medial condyle (RMSD: lunge: 2.2±1.0 mm, level walking: 2.4±0.9 mm, stair descent: 2.2±0.6 mm) and lateral condyle (RMSD: lunge: 2.4±1.4 mm, level walking: 2.2±1.4 mm, stair descent: 2.7±2.0 mm). Patellar medial-lateral tilt (RMSD: 3.4±3.8°) and medial-lateral shift (RMDS: 1.5±0.6 mm) during knee flexion matched closely between groups. Conclusion. Throughout the comprehensive functional assessments the investigated PKA system behaved nearly identical to the intact knee. The small residuals are unlikely to have a clinical effect; further studies are necessary as cadaveric studies are not necessarily indicative of clinical results. We conclude that PKA with anatomical, compartment specific shapes and fine-tuned mechanical instrumentation can be adapted precisely to the complex mechanics of the knee and replicates intact knee balance and kinematics very closely


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 7 - 7
1 May 2016
Longaray J Hooks B Herrera L Essner A Higuera C
Full Access

Prosthetic Hip dislocations remain one of the most common major complications after total hip arthroplasty procedures, which has led to much debate and refinement geared to the optimization of implant and bearing options, surgical approaches, and technique. The implementation of larger femoral heads has afforded patients a larger excursion distance and primary arc range motion before impingement, leading to lowered risk of hip dislocation. However, studies suggest that while the above remains true, the use of larger heads may contribute to increased volumetric wear, trunnion related corrosion, and an overall higher prevalence of loosening, pain, and patient dissatisfaction, which may require revision hip arthroplasty. More novel designs such as the dual mobility hip have been introduced into the United States to optimize stability and range of motion, while possibly lowering the frictional torque and modes of failure associated with larger fixed bearing articulations. Therefore, the aim of this study is to compare the effect of bearing design and anatomic angles on frictional torque using a clinically relevant model8. Two bearing designs at various anatomical angles were used; a fixed and a mobile acetabular component at anatomical angles of 0°,20°,35°,50°, and 65°. The fixed design consisted of a 28/56mm inner diameter/outer diameter acetabular hip insert that articulated against a 28mm CoCr femoral head (n=6). The mobile design consisted of a 28mm CoCr femoral head into a 28/56mm inner diameter/outer diameter polyethylene insert that articulates against a 48mm metal shell (n=6). The study was conducted dynamically following a physiologically relevant frictional model8. A statistical difference was found only between the anatomical angles comparison of 0vs65 degrees in the mobile bearing design. In the fixed bearing design, a statistical difference was found between the anatomical angles comparison of 20vs35 degrees, 20vs50 degrees, and 35vs65 degrees. No anatomical angle effect on frictional torque between each respective angle or bearing design was identified. Frictional torque was found to decrease as a function of anatomical angle for the fixed bearing design (R2=0.7347), while no difference on frictional torque as a function of anatomical angle was identified for the mobile bearing design. (R2=0.0095). These results indicate that frictional torque for a 28mm femoral head is not affected by either anatomical angle or bearing design. This data suggests that mobile design, while similar to the 28mm fixed bearing, may provide lower frictional torque when compared to larger fixed bearings >or= 32mm8. Previous work by some of the authors [8] show that frictional torque increases as a function of femoral head size. Therefore, this option may afford surgeons the ability to achieve optimal hip range of motion and stability, while avoiding the reported complications associated with using larger fixed bearing heads8. It is important to understand that frictional behavior in hip bearings may be highly sensitive to many factors such as bearing clearance, polyethylene thickness/stiffness, polyethylene thickness/design, and host related factors, which may outweigh the effect of bearing design or cup abduction angle. These factors were not considered in this study


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_20 | Pages 45 - 45
1 Dec 2017
Sriphirom P Siramanakul C Sirisak S Chanopas B Setasuban P
Full Access

The “correct” rotational alignment and “normal” rotational alignment may not be the same position. Because of natural tibial plateau has average 3° varus but classical TKA method make tibial cut perpendicularly to tibial mechanical axis. Consequently femoral rotational compensation to 3° becomes necessary. While anatomical TKA method performed tibial cut in 3° varus. Then posterior femoral cut will be parallel to posterior condylar axis and component rotation theoretically should be aligned in natural anatomy. This study compares the rotational alignment between two methods. Study conducted on 80 navigated TKAs with modified gap technique. Intraoperative femoral rotation retrieved from navigation. Rotational alignment was calculated using the Berger protocol with postoperative computerised tomography scanning. The alignment parameters measured were tibial and femoral component rotations and the combined component rotations. 57 knees with PS design can be classified into 35 knees as anatomical group and 22 knees as classical group. 23 knees with CR design had 12 knees as anatomical group and 11 knees as classical group. The intraoperative femoral rotation in anatomical group had less external rotation than classical group significantly in PS design (0.77°±1.03° vs 2.86°±1.49°, p = 0.00) and also had the same results in CR design (1.33°±1.37°vs 2.64°±0.81°, p = 0.012). However, the postoperative excessive femoral and tibial component rotation compared with native value and combined rotation had no significant differences between classical and anatomical method in both implant design. Using CAS TKA with gap technique showed no difference in postoperative rotational alignment between classical and anatomical method


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 88 - 88
1 Feb 2017
Levy J Formaini N Kurowicki J
Full Access

Background. Radial head arthroplasty (RHA) is a popular method of treatment for complex fractures of the radial head. The purpose of this study was to investigate patient outcomes and radiographic findings associated with a single anatomical monopolar press-fit radial head system commonly used for the treatment of radial head fractures. Methods. A retrospective review of prospectively collected data was performed for a consecutive series of patients treated with RHA between November 2007 and April 2014. Patients with a minimum of 12-month follow-up were included. Most recent radiographs were evaluated for loosening, stress shielding, and instability. Post-operative motion and outcomes were reported at most-recent follow-up. Results. At an average follow-up of 30 months, 7 of the 17 patients (41%) demonstrated radiographic loosening. Six of the 10 patients (60%) without loosening demonstrated stress shielding (average 6mm). Functional outcome scores included a mean ASES of 74, MEPS of 87, VAS Pain of 1, VAS Function of 8 and SANE of 79. Average flexion-extension arc was 13°–138°, and average pronation-supination was 77°–76° (Figure 1). Of the patients with radiographic loosening, 86% had undergone RHA with an associated ligamentous injury of the elbow. Satisfaction among patients was high, as no patient reported an unsatisfactory outcome. Conclusions. The use of an anatomic, press-fit monopolar RHA in the management of acute complex radial head fractures has yielded excellent clinical outcomes despite high rates of radiographic loosening and stress shielding. Press-fit RHA in the setting of ligamentous injury warrants further investigation due to a high rate of implant loosening observed


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 42 - 42
1 Aug 2013
Murphy W Kowal J Murphy S
Full Access

Introduction. Conventional methods of aligning the acetabular component during hip arthroplasty and hip resurfacing often rely upon anatomic information available to the surgeon. Such anatomical information includes the transverse acetabular ligament and the locations of the pubis, ischium and ilium. The current study assesses the variation in orientation of the plane defined by the pubis, ischium and ilium on a patient-specific basis as measured by CT. Methods. To assess the reliability of anatomical landmarks in surgery, we assessed 54 hips in 51 patients (32 male, 22 female) who presented for CT-based surgical navigation of total hip arthroplasty. From a 3D model of each patient, standardised points for the anterior pelvic plane and landmarks on the ilium, ischium, and pubis were entered. The plane defined by the anatomical landmarks was calculated in degrees of operative anteversion and operative inclination according to the definitions of Murray. Results. The plane representing cup position defined by the anatomical landmarks ranged from 7.8° to 64.6° in operative anteversion (mean = 32.1°, SD = 15.0°) and 37.6° to 68.2° in operative inclination (mean = 53.2, SD = 7.1°). If a safe zone of 27 degrees of operative anteversion (± 10°) and 42 degrees of operative inclination (± 10°) is selected, 50.0% of hips are out of the safe zone in operative anteversion, and 57.4% of hips are out of the safe zone in operative inclination. Discussion and Conclusion. Surgeons have very specific and limited anatomical information available at the time of surgery to assist in determining optimal component orientation. Alignment relative to the operating table and intraoperative signs such as the co-planar test are unreliable due to the wide variation of position of the pelvis during surgery. This leaves anatomical landmarks that can be palpated during surgery as one remaining method upon which component orientation may be based. Unfortunately, these anatomical landmarks vary quite widely on an individual patient basis, with 83.3% of hips out of the a safe zone in this study of 27° of operative anteversion and 42° of operative inclination and 77.8% our of a safe zone of 20 degrees of operative anteversion and 45 degrees of operative inclination. As such, internal anatomical landmarks are likely to lead to systematically high incidences of component malposition such as those repeatedly documented in the literature. Based on the current study we conclude that, unless the orientation of the palpable anatomical landmarks is assessed in three-dimensions pre-operatively, these anatomical landmarks provide poor and sometimes dangerously misleading information


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 87 - 87
1 Jan 2016
Clarke I Sufficool D Bowsher JG Savisaar C Burgett-Moreno M Donaldson T
Full Access

Introduction. Hip simulators proved to be valuable, pre-clinical tests for assessing wear. Preferred implant positioning has been with cup mounted above head, i.e. ‘Anatomical’ (Figs. 1a-c) . 1,2. while the ‘Inverted’ test (cup below head) was typically preferred in debris studies (Figs. 1d-f). 3,4. In an Anatomical study, wear patterns on cups and heads averaged 442 and 1668 mm² area, respectively, representing 8% and 30% of available hemi-surface (Table 1), i.e. the head pattern was ×3.8 times larger than cup. This concept of wear patterns is illustrated well in the ‘pin-on-disk’ test (Fig. 1) in which the oscillating pin has the ‘contained’ wear area (CWP) and the large wear track on the disk is the ‘distributed’ pattern (DWP). Hip simulators also create CWP and DWP patterns, site dependant on whether Anatomical (Fig. 1a-c) or ‘Inverted’ (Fig. 1d-f) test. However there is scant foundation as to clinical merits of either test mode. Retrieval studies of MOM bearings have indicated that cups have the larger wear patterns, i.e. contrary to simulator tests running Anatomical cups (Table 1). 5. Therefore we compared Anatomical and Inverted cup modes using 38mm and 40mm MOM in two 5-million cycle simulator studies. Methods. 38mm and 40mm MOM bearings were run in Anatomical mode (study-1) and Inverted (study-2) mode, respectively, in a hip simulator. Lubricant was bovine serum diluted to provide protein concentration 17 mg/ml. Wear was measured gravimetrically and wear-rates calculated by linear regression. Wear patterns were assessed by stereomicroscopy and compared to algorithms using standard spherical equations. Results. MOM wear-rates ranged 0.3 to 6 mm³/Mc by 5-million cycles duration. Contained wear patterns (CWP) averaged 410 mm² for cups in study-1 (Anatomical) and 397 mm² for heads in study-2 (Fig. 3: Inverted). Distributed wear patterns (DWP) averaged 945mm² in study-1 (heads, Anatomical) and 846mm² in study-2 (cups, Inverted). Cup Hemi-ratios averaged 18% and 38% in studies 1 and 2 respectively (Table 2). Discussion. While vendor, implant and experimental differences were clearly present, study-1 (Anatomical) and study-2 (Inverted) produced almost identical CWP and DWP wear patterns, only reversed on heads versus cups. This unequivocal evidence demonstrated that there was no difference in wear mechanics for spherical CoCr bearings run in either test mode. In addition, wear patterns observed in MOM cup retrievals. 5. (1000–2700 mm²) were much larger than produced in Anatomical simulator tests (Fig. 2h: 400–500 mm²). Such large discrepancies in cup wear patterns between Anatomical simulator tests and retrieved MOM cups indicated that the Inverted cup mode (Fig. 2g) may be more clinically relevant


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 443 - 443
1 Dec 2013
Murphy S Murphy W Kowal JH
Full Access

Introduction:. Conventional methods of aligning the acetabular component during hip arthroplasty and hip resurfacing often rely upon anatomic information available to the surgeon. Such anatomical information includes the transverse acetabular ligament and the locations of the pubis, ischium and ilium. The current study assesses the variation in orientation of the plane defined by the pubis, ischium and ilium on a patient-specific basis as measured by CT. Methods:. To assess the reliability of anatomical landmarks in surgery, we assessed 54 hips in 51 patients (32 male, 22 female) who presented for CT-based surgical navigation of total hip arthroplasty. The HipSextant Research Application (version 1.0.7, Surgical Planning Associates Inc., Boston, Massachusetts) was used to perform the calculations. This application allows for determination of the Anterior Pelvic Plane coordinates from a 3D surface model. Standardized points on the ilium, ischium, and pubis were entered. These three points defined a plane and the orientation of the plane in the AP Plane coordinate system was calculated in degrees of operative anteversion and operative inclination according to the definitions of Murray. 1. . Results:. The plane representing cup position defined by the anatomical landmarks ranged from 7.8° to 64.6° in operative anteversion (mean = 32.1°, SD = 15.0°) and 37.6° to 68.2° in operative inclination (mean = 53.2, SD = 7.1°). If a safe zone of 27 degrees of operative anteversion (± 10°) and 42 degrees of operative inclination (± 10°) is selected, 50.0% of hips are out of the safe zone in operative anteversion, and 57.4% of hips are out of the safe zone in operative inclination. 83.3% of all hips are out of the safe zone in either operative anteversion, operative inclination, or both. If a safe zone of 20° of operative anteversion (± 10°) and 45° of operative inclination (± 10°) is assumed, 55.6% of hips are out of the safe zone in operative anteversion, 44.4% of hips are out of the safe zone in operative inclination, and 77.8% of hips are out of safe zone for either anteversion or inclination. Discussion and Conclusion:. Surgeons have very specific and limited anatomical information available at the time of surgery to assist in determining optimal component orientation. Alignment relative to the operating table and intraoperative signs such as the co-planar test are unreliable due to the wide variation of position of the pelvis during surgery. This leaves anatomical landmarks that can be palpated during surgery as one remaining method upon which component orientation may be based. Unfortunately, these anatomical landmarks vary quite widely on an individual patient basis, with 77.8% out of a safe zone of 20 degrees of operative anteversion and 45 degrees of operative inclination +/− 10 degrees. As such, internal anatomical landmarks are likely to lead to systematically high incidences of component malposition such as those repeatedly documented in the literature. Based on the current study we conclude that, unless the orientation of the palpable anatomical landmarks is assessed in three-dimensions pre-operatively, these anatomical landmarks provide poor and sometimes dangerously misleading information


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 54 - 54
1 Jan 2016
Idei J Sekiguchi M Kubota A Ohikata Y Yamamoto K Tsuchiya K Murase T
Full Access

Introduction. Recently, computer-aided orthopaedic surgery has enabled three dimensional (3D) preoperative planning, navigation systems and patient matched instrument, and they provide good clinical results in total knee arthroplasty. However, the preoperative planning methods and the criteria in total elbow arthroplasty (TEA) still have not sufficiently established due to the uncertainty of 3D anatomical geometry of the elbow joints. In order to clarify the 3D anatomical geometry, this study measured 3D bone models of the normal elbow joints. Additionally this study attempted to apply the 3D preoperative planning to ordinary surgery. Then the postoperative position of implant has evaluated as compared with the position in 3D preoperative planning. Methods. Three dimensional bone measurements on 4 normal cases were performed. Three dimensional bone models were constructed with CT image using Bone Viewer®(ORTHREE Co., Ltd.). TEA was performed with FINE® Total Elbow System (Nakashima Medical Co., Ltd.) for 3 rheumatoid arthritis (RA) cases (Fig. 1). Three dimensional preoperative planning was based on this bone measurement, and postoperative position of implant were evaluated. The postoperative assessments were evaluated by superimposing preoperative planning image on postoperative CT image using Bone Simulator® (ORTHREE Co., Ltd.). This study only covers humeral part. Results. The results of 3D bone measurements on 4 normal cases shows the average internal rotation angle between the flexion-extension axis and the epicondyles axis in the distal humerus was 2.2 degrees. The average valgus tilt of the distal humerus was 3.7 degrees. Postoperative position of humeral component for 3 RA cases was installed at proximal and valgus position compared to the preoperative planning. Discussion. This study indicates that ordinary two dimensional criteria and 3D anatomical one in the elbow joint may be different in several bony landmarks such as rotation, varus and valgus. Additionally these results show the differences between postoperative position of implant and preoperative position in 3D planning. More studies need to be conducted to validate postoperative evaluation and preoperative planning


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_14 | Pages 17 - 17
1 Jul 2016
Edwin J Baskaran D Raja F Ahmed B Verma S Compson J
Full Access

The scaphotrapeziotrapezoid (STT) joint is one of the key link joints between the proximal and the distal carpal rows. We assessed the relationship between the scaphotrapezium (STm) andscaphotrapezoid (STd) joints using computerised tomographyand hypothesised the ratio of STm is =/< STd joint due to which, the possibility of failure of trapeziectomy due to metacarpal collapse is insignificant. We reviewed CT scans of wrist joints of 113 eligible patientsfrom our wrist database between 2009 and 2014 for our study. 31 patients were randomised for interobserver correlation. Reformatted multi-planar sequences were analysed. The ratio of theSTm: STdin sagittal and coronal measurementswas evaluated. Interobserver variations were assessed using the Pearson coefficient. The sex distribution included 68 males and 29 females, 49 left and 64 right wrists. The STm area was larger in 86 (76%) as compared to STd in 27(24%). Average trapezium to trapezoid ratio was 1:1.5. Ratio of area of trapezium: trapezoid joint is 0.30. The anatomic ratio of the STm in the coronal and sagittal planesis 0.3 and that of the STd joint is 0.2. Ratio of the STm: STd in the coronal plane is 0.29. Pearson's coefficient > 0.8. A small subset of patients undergoing trapeziectomy alonefor stage II- IV carpometacarpal arthritis of the thumb are at risk of impingement of the first metacarpal due to collapse. Our assessment of the anatomical relationship of the STT joint with CT scan proves that although the area the STm joint is generally larger than the STd joint, there is no significant correlation on the whole


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 130 - 130
1 Jan 2016
Park C Ranawat CS Ranawat AS
Full Access

Introduction. Potential implant and technique related factors to improve patellofemoral (PF) kinematics in total knee arthroplasty (TKA) are design of trochlear geometry and patella, restoration of posterior offset, patellar tilt and avoid overstuffing. The primary aim of this prospective, matched pair study was to assess the radiographic features of PF kinematics with an anatomic patella. Material and Methods. Between July 2012 and May 2013, 49 consecutive posterior stabilized cemented Attune TKAs (Depuy Synthes Warsaw Indiana) were matched to the 49 PFC Sigma (Depuy) based on age, gender, and body mass index (BMI). All surgeries were performed via medial parapatellar approach with patellar resurfacing. Radiographic analysis was performed prospectively with minimum 1-year follow-up and included overall limb alignment, anterior offset, posterior offset, joint line, patellar thickness, patellar tilt and patellar displacement by two independent observers. Results. We found significant improvement in all post-operative radiographies parameters from prior to surgery, however, there was no significance between the two groups (Table 1). Posterior offset and joint line were restored in all cases and no overstuffing of the PF joint was seen. Discussion. At minimum one-year follow-up, anatomical patella has excellent safety and efficacy with restoration of the PF kinematics. Metalized design of the Attune anatomic patella component allows better contact with trochlear groove and improves tilt with lateralization of the patella


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 134 - 134
1 May 2016
Plachel F Heuberer P Schanda J Pauzenberger L Anderl W
Full Access

Background. The use of reverse total shoulder arthroplasty considerably increased since first introduced by Paul Grammont in the late 1980s. Over the past few years, results from several mid- and long-term clinical studies have demonstrated good functional outcomes and pain relief. However, several complications, especially inferior glenoid notching, and high revision rates were reported in the literature. Improvements in prosthesis design should contribute to a lower complication rate and lesser amount of glenoid erosion. Few studies have reported the clinical outcome andcomplications of Anatomical Shoulder Inverse/ Reverse Prosthesis. This study documents 2- and 6-year clinical and radiological results following reversed shoulder arthroplasty using this novel prosthesis. Methods. We report the results for sixty-eight consecutive patients (seventy shoulders) with cuff tear arthropathy (CTA) treated with Anatomical Shoulder Inverse/Reverse Prosthesis between 2006 and 2008. Two groups were defined: (A) primary treatment and (B) revision. Clinical evaluation tools comprised Constant-Murley score (CS), range of motion, and a visual analog scale to assess pain. Radiographs (anteroposterior view in neutral position) were evaluated for notching and radiolucent lines. Any complications were recorded. Results. In total, 66 shoulders (94%) with a mean follow-up of 30.0 months were initially analysed. CS increased from preoperatively 20.2 to postoperatively 53.6 points. Inferior scapular notching was identified in 58% of patients, primarily grade 1 and 2 (low-graded). 16% of patients experienced a complication, including instability, infection or periprosthetic fracture. 58 patients (83%) were re-evaluated 69.0 months after implantation. CS decreased to 50.2 points (n.s.). 16 patients (23%) had postoperative complication at final follow-up. We observed progressive radiographic changes in 75% and an increased frequency of large notches (grade 3 and 4). No significant difference regarding clinical outcome was detected between group A and B after both 2 and 6 years. Conclusion. Total shoulder arthroplasty with the Anatomical Shoulder Inverse/Reverse Prosthesis is a reliable treatment option in patients with cuff tear arthropathy. Primary and revision arthropathies result in similar improvements in range of motion and pain. Constant-Murley score and radiographic changes deteriorated with time. Inferior scapular notching appeared rapidly after implantation. A change of prosthesis design and prosthetic overhang intraoperatively seems to be the most effective way to prevent scapular conflict. The complication rate in our series is equally to previously reported rates


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 341 - 341
1 Mar 2013
Suenaga N Urita A Miyoshi N Oizumi N Yoshioka C
Full Access

Introduction

We performed humeral head replacement (HHR) with smaller head for closing the cuff defect in patients of cuff tear arthropathy (CTA). And also, if the cuff defect could not close by decreasing the head size, we add muscle tendon transfer such as latissimus dorsi transfer for posterosuperior defect and pectoralis major transfer for anterosuperior defect.

Aim

The purpose of this study was to investigate clinical and functional outcomes of this procedure for CTA according to Hamada-Fukuda classification.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 105 - 105
1 Feb 2017
Lazennec J Fourchon N Folinais D Pour A
Full Access

Introduction. Limb length discrepancy after THA can result in medicolegal litigation. It can create discomfort for the patient and potentially cause back pain or affect the longevity of the implant. Some patients tolerate the length inequality better compared to others despite difference in anatomical femoral length after surgery. Methods and materials. We analyzed the 3D EOS images of 75 consecutive patients who underwent primary unilateral THA (27 men, 48 women). We measured the 3D length of the femur and tibia (anatomical length), the 3D global anatomical length (the sum of femur and tibia anatomical lengths), the 3D functional length (center of the femoral head to center of the ankle), femoral neck-shaft angle, hip-knee-ankle angle, knee flexum/recurvatum angle, sacral slopes and pelvic incidence. We correlated these parameters with the patient perception of the leg length. Results. The values for leg length and pelvic parameters are shown in table 1. 37 patients had a perception of the LLD (49.3%). When the global anatomical length was shorter on the operated side, the perception of the discrepancy was observed in 56% of the cases. In case of anatomical length longer on the operated side, the perception of the discrepancy was described by the patients in 46% of the cases. The LLD perception was correlated with difference in functional length (p=0.0001), pelvic obliquity (p=0.003) and sacral slope (p=0.023). The anatomical femoral length was not correlated with the LLD perception (p=0,008). Discussion. The perception of LLD is a multifactorial complication. We found that the anatomical femoral length (that can be directly affected by the position of the stem) is not the only important factor. The functional length of the lower extremity which can also be affected by the knee deformities is better correlated with the LLD. The pelvic obliquity and version also affect the patient perception of the LLD


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 79 - 79
1 Jan 2016
Tsujimoto T Hashimoto Y Ando W Koyama T Yamamoto K Ohzono K
Full Access

INTRODUCTION. The concept of anatomical stam is fit-and-fill in the proximity of the femur and to expect wall fixation, following to reduce thigh pain and stress shielding. Although the femoral medullary form and size are different in each races. CentPillar TMZF stem (stryker . ®. ) is anatomical stem designed based on computer-tomography of Japanese femurs. The purpose of this study was to evaluate clinical and radiographic outcomes of CentPillar TMZF stem at a mean of 3.6 years postoperatively. METHODS. We asseses the results of 98 primary total hip arthroplasty (THA) performed using a CentPillar TMZF stem in 91 Japanese patients (4 males, 94 females) undergoing surgery between August 2007 and June 2011, the mean age at the time of surgery was 62.0 (41–81) years old. The Diagnosis were osteoarthritis (OA) in 91 hips, rapidly destructive coxopathy (RDC) in 4 hips, rheumatoid arthritis (RA) in 3 hips. Clinical and radiographic assessments were performed for every patient for every follow up using Japan Orthopaedic Association (JOA) Score, thigh pain, revision surgery and complications. Radiographic assessments were including stem alignment on anteroposterior radiograph, stress shielding, bone remodeling, radiolucent line, osteolysis, loosening and subsidence. RESULTS. 50.7 points of the postoperative mean JOA score was significantly improved to 96.3 points postoperatively. No patients showed thigh pain. Intraoperative calcar fracture was occurred in 1 hip. In 97 hips of 98 hips (98%) stem was implanted in neutral position (within ±3 degrees). With regard to stress shielding, 69 hips (70%) had none or only 1. st. degree resorption; 29 hips (30%) had 2. nd. degree and no cases had 3. rd. and 4. th. degree. Spot welds were developed in 71 hips (71%; Gruen zone 2 and 6), and cortical hypertrophy were observed in 2 hips (2%; Gruen zone 3 and 5). No cases developed radiolucent line, osteolysis, loosening, and subsidence. No revision surgery were requied up to 5.8 years postoperatively. DISCUSSION AND CONCLUSION. CentPillar TMZF stem provided a stable fixation, with excellent short-term clinical and radiographic outcomes. The strong proximal fixation was predictably enabled, and there were few cases fixed distal portion of the femur. These finding suggested CentPillar TMZF stem fits Japanese medullary form and can expect the long-term survival


Introduction. Limb-length discrepancy (LLD) is a common postoperative complication after total hip arthroplasty (THA). This study focuses on the correlation between patients’ perception of LLD after THA and the anatomical and functional leg length, pelvic and knee alignments and foot height. Previous publications have explored this topic in patients without significant spinal pathology or previous spine or lower extremity surgery. The objective of this work is to verify if the results are the same in case of stiff or fused spine. Methods. 170 patients with stiff spine (less than 10° L1-S1 lordosis variation between standing and sitting) were evaluated minimum 1 year after unilateral primary THA implantation using EOS® images in standing position (46/170 had previous lumbar fusion). We excluded cases with previous lower limbs surgery or frontal and sagittal spinal imbalance. 3D measures were performed to evaluate femoral and tibial length, femoral offset, pelvic obliquity, hip-knee-ankle angle (HKA), knee flexion/hyperextension angle, tibial and femoral rotation. Axial pelvic rotation was measured as the angle between the line through the centers of the hips and the EOS x-ray beam source. The distance between middle of the tibial plafond and the ground was used to investigate the height of the foot. For data with normal distribution, paired Student's t-test and independent sample t-test were used for analysis. Univariate logistic regression was used to determine the correlation between the perception of limb length discrepancy and different variables. Multiple logistic regression was used to investigate the correlation between the patient perception of LLD and variables found significant in the univariate analysis. Significance level was set at 0.05. Results. Anatomical femoral length correlated with patients’ perception of LLD but other variables were significant (the height of the foot, sagittal and frontal knee alignment, pelvic obliquity and pelvic rotation more than 10°). Interestingly some factors induced an unexpected perception of LLD despite a non-significant femoral length discrepancy less than 1cm (pelvic rotation and obliquity, height of the foot). Conclusions. LLD is a multifactorial problem. This study showed that the anatomical femoral length as the factor that can be modified with THA technique or choice of prosthesis is not the only important factor. A comprehensive clinical and radiological evaluation is necessary preoperatively to investigate spinal stiffness, pelvic obliquity and rotation, sagittal and coronal knee alignment and foot deformity in these patients. Our study has limitations as we do not have preoperative EOS measurements for all patients. We cannot assess changes in leg length as a result of THA. We also did not investigate the degree of any foot deformities as flat foot deformity may potentially affect the patients perception of the leg length. Instead, we measured the distance between the medial malleolus and ground that can reflect the foot arch height. More cases must be included to evaluate the potential influence of pelvis anatomy and functional orientation (pelvic incidence, sacral slope and pelvic tilt) but this study points out that spinal stiffness significantly decreases the LLD tolerance previously reported in patients without degenerative stiffness or fusion