Depression is a common co-morbidity in Total Hip Arthroplasty (THA). Chronic pain and depression influence one another. Postoperative outcomes and satisfaction rates are affected by depression. The aim of the study was to determine the impact of pre-operative depression on patient functional outcomes and satisfaction rates after THA. A secondary objective was to assess potential change in the incidence of depression at mid-term post-operative follow-up.Introduction
Objectives
The prevalence of immunocompromised patients undergoing Total Hip Arthroplasty (THA) is increasing worldwide as a consequence of advances in treatment. HIV is presenting in an older population group and concerns of higher rates of infection, early failures and dangers posed to healthcare workers exist. This study is imperative to predict future burden of THA and make subsequent provisions The objective was to determine the seroprevalence of HIV in patients presenting for THA in an academic institution in a developing country. Secondarily, the aim was to determine if there is any difference in the seroprevalence of patients undergoing THA and TKA and finally to assess the status of disease control in seropositive patients eligible for TJA on pre-existing HAART.Background
Objectives
Total Hip Replacement (THR) is a proven and effective surgical procedure. One of the main limiting factors of the longevity of THR is the performance of the bearing surface. The optimum bearing surface choice, however, remains controversial. We wanted to understand what influenced the choice of bearing surfaces amongst South African orthopaedic surgeons. We also wanted to know if there was any consensus between surgeons and the orthopaedic trade. There is no epidemiological registry-based data available in South Africa in respect of bearing surfaces used in hip replacements. We sent out an electronic survey to all members of the South African Orthopaedic Association as well as to trade representatives. Patient parameters influencing the choice of bearing surfaces were surveyed and these included age, gender, level of activity and diagnosis. We used a regressional and tree analysis methodology to interpret the results.Introduction:
Aims, material and methods:
Antibiotic prophylaxis prior to dental and other procedures when patients have joint replacements in situ remains controversial. Recommendations seem to generally be intuitive and not based on any sound scientific evidence. Recently, the American Academy of Orthopaedic Surgeons altered their previous standpoint and suggested that orthopaedic surgeons review their current practice of routine prescription of antibiotic prophylaxis. We conducted an electronic survey of members of the South African Orthopaedic Association to determine the opinion of the average orthopaedic surgeon in South Africa in respect of this prophylaxis. 111 surgeons responded.Background:
Method:
Massive acetabular defects remain an unresolved challenge in revision arthroplasty surgery of the hip. We report on 7 patients treated with custom made acetabular components to manage these massive boney defects. After high resolution CT scans were done, custom made implants were designed in collaboration between the surgeons and the manufacturer. All implants matched the bony defects as designed.Background:
Methods:
We report on a series of long-stemmed femoral components used in revision total hip replacements which fractured, and were subsequently revised. All explanted stems were analysed in respect of the reasons for failure. The patient's serial radiographs and clinical records were also analysed. All stems demonstrated some fixation distally. They all showed little proximal osteo-integration. A biomechanical analysis confirmed the vulnerability of these long stemmed modular prostheses in respect of mechanical failure. The resultant unprotected lever-arms led to local stresses in the prosthesis constructs which were above the failure threshold resulting in prosthesis fractures. These fractures all occurred at points where the prostheses were structurally most vulnerable.Methods
Results
Antibiotic loaded polymethyle methacrylate spacers are commonly used in the management of septic hip replacements. The aim of this study was to determine wear patterns on the articulating surfaces of these spacers, as well as to determine the extent of PMMA particulate debris generation.Introduction
Aim
Metal ion levels are used to track the performance of metal containing bearings in hip replacement patients. Changes in whole blood metal ion levels are indicators of wear rates in these bearings. Normal metal ion levels are variable, and range widely. Changes in these “non-bearing” levels over a period of time may influence the monitoring of these bearings. As part of a prospective randomised trial of different bearing surfaces, whole blood metal ion levels were monitored. This included four cohorts of patients, namely ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC) and ceramic-on-metal (CoM). Serial whole blood metal ion levels in the non-metal bearings, namely CoC and CoP, were analyzed. There was no consistency in these whole blood metal ion levels. Intra-patient variations in these levels over a period of time could not be due to bearing-produced metal ions as these were all metal free, and thus not the source of any endogenous ions. These intra-patient variations may reflect changes in exogenous exposure to these metal ions, fluctuations in these patient's metabolic functions or production of metal ions from non-bearing prosthetic sources.Methods.
Results.
The advantages of computer navigated total knee replacement are well documented in the literature, however, increased surgical time and cost issues remain the major deterrent for the wide use of this technology. Placement of cutting jigs under computer guidance forms a major aspect of computer assisted knee replacement surgery. The use of a motorized mini-robotic cutting jig allows for a more precise and time efficient execution of the femoral cuts under computer guidance. We present a preliminary report on our experience using standard computer assisted surgery (CAS) jigs and mini robotic motorized jigs in computer navigated knee replacement We compared our experience using standard jigs and mini-robotic jigs in knee replacement. A cohort of patients involved in a study comparing navigated and standard total knee replacements received TKA using a Bi-Cruciate Stabilised Knee System. A pilot cohort of patients received total knee replacement using standard computer navigation by the pi galileo system without the mini-robots while awaiting acquisition of the mini robot system. We compared our experience using the same pi galileo system with mini robotic cutting jigs to the cohort without the mini-robotic cutting guides. Reduction in surgical time was statistically significant when using the motorized mini robotic jigs. Blood loss was identical in both cohorts, and cut precision was better in the cohort with the motorized mini robotic jigs.Methods:
Results:
To look at the difference in metal ion levels using Ceramic on Metal (COM) and Metal on Metal (MOM) bearings in Total Hip Replacements, comparing the results between well placed and poorly placed cups. Metal ion levels using the ICP-MS method of assay have been studied as part of a prospective randomised trial between 4 different bearing combinations. The ion levels have been raised in the COM and MOM bearings. Metal ions are not raised in the Ceramic on Ceramic (COC) and Ceramic on X linked Poly(COP) bearings, showing that no other material in the study prosthesis aside from the bearing surfaces contribute to raised ion levels. Cup inclination and cup anteversion has been measured in all patients.Purpose of Study:
Methods:
Monitoring the performance of hip replacements post-operatively is tedious and costly, necessitating radiological examinations as well as other specialized examinations such as whole blood metal ion levels. In an effort to control escalating costs, we conducted an ethically approved clinical trial to assess the efficacy of basic acoustic monitoring equipment to asses these implants. An electronic stethoscope was successfully used to record sounds from the hips of participants with different bearing surfaces. The sounds were recorded while conducting a standardized movement sequence. A 5th order Savitzky-Golay filter with a window width of 21 points was used to remove background noise. The recordings were also listened to by ear and three primary classes of sounds were identified. Frequency components contained in the classes were identified using spectrograms and Welch power density spectra. The sounds were correlated with different patient factors including component positioning, BMI and length of time that the implant was in situ. The skewness and kurtosis of the power spectra were calculated and found to be different for each class. Further frequency analysis was conducted with the aid of the discrete wavelet transform. This met with some success as different frequency levels were found in each sound class. All bearing surfaces produced some noise. The most sounds were produced by the ceramic-on-metal group, even though not in the audible range, and those participants with a body mass index in the obese range. Sounds were also detected in the ceramic-on-polyethylene implants. However, no consistent links between these factors and the sounds produced could be identified. Specifically, the lack of correlation between sound occurrence and length of implantation indicates that this technique is not useful in predicting possible failures or future complications in real time.Method.
Results.
The search for the ideal bearing surface in Total Hip Replacements continues. The current ‘best’ materials are felt to be combinations of metal, ceramics and cross-linked polyethylene. Laboratory studies suggest that ceramic-on-metal articulations may provide distinct advantages. This study aims to identify the best bearing surface combination with the lowest adverse side effect profile. Between February 2004 and September 2007, 164 hips were replaced in 142 patients. 39% were male and 69% were female. The average age at surgery was 53 years (17-72 years). Follow-up assessment included radiographs, the Harris Hip Score and whole blood samples for metal ion levels. Complications to date included 3 hips which needed femoral revision because of surgery related factors, and 3 cases of sepsis of which 1 settled and 2 needed revision. One hip needed revision of head and liner to a larger bearing size for recurrent dislocations, and is no longer being followed up for blood metal ions. Post-operative whole blood metal ion levels were compared to pre-operative levels to determine the increase or decrease in metal ion levels. There were no changes in those patients with ceramic-on-ceramic and ceramic-on-polyethylene articulations. Moderately raised whole blood metal ion levels were noted at 3 months in the ceramic-on-metal group, while the metal-on-metal group show the greatest increase. This study agrees with laboratory bearing surface wear studies demonstrating lower wear rates in the ceramic-on-metal group compared to the metal-on-metal group. With concerns related to high blood metal ion levels in metal-on-metal articulations, ceramic-on-metal bearing surfaces may well become a bearing surface of choice in the future, but progress needs to be monitored in the longer term.
The combination of a ceramic head articulating against a metal acetabular liner (CoM) has shown reduced metal ion levels compared with a metal-on-metal bearing (MoM) in hip simulator studies. A randomized prospective clinical trial was undertaken using CoM and MoM bearings in an otherwise identical total hip procedure. The initial clinical results were encouraging. This report comprises a further review of metal ion data. Patients received identical components with the exception of the bearing surface material but all were 28mm diameter. All components were supplied by DePuy International Ltd. Patients were assessed pre-operatively, 3m, 12m and >
24m (median 32m). Whole blood samples were collected at regular follow-ups, frozen and analysed in batches using high resolution Inductively Coupled Plasma – Mass Spectrometry (ICP-MS). All recruited patients are included irrespective of outcome. However some patients failed to attend specific follow-ups and some contaminated samples had to be discarded. Statistical significance was analyzed using a non-parametric comparison (Mann-Whitney test). After 3m and 12m implantation there were between 21 and 24 patients available for analysis in both the CoM and MoM cohort and after >
24m point 10 and 9 respectively. There were four outliers (either Cr or Co >
10ug/l) in both the CoM and MoM groups. In common with previous studies (with the exception of two marginal outliers), these were related to component position. They were implanted with either a cup abduction angle of >
55°, an anteversion angle of >
30° or both. Other studies with the same design of component have reported no significant outliers. The median Cr and the Co levels are lower with the CoM bearing compared with the MoM at all measurements points following implantation. The median background (pre-operative) levels for the combined CoM and MoM group were Cr: 0.22ug/l and Co: 0.49ug/l. These were significantly different (p=0.006). In the CoM group, the median 12m Cr and Co values were 0.43ug/l and 0.72ug/l respectively. The comparable values for MoM are 0.68ug/l and 0.83ug/l. Increases in metal ion levels from pre-operative levels are used as the primary ion level outcome in this study because the background level will comprise of the order of 30–50% of the overall value. The increase in Cr for CoM and MoM from pre-op levels to 12m significantly different for Cr (p=0.015). It has a lower significance for combined metal ion levels (p=0.029). This difference in not significant for Co (p=0.195). In agreement with predictions from hip simulator studies, CoM bearings in this study produced lower levels of metal ions than comparable MoM bearings at all time points. However the difference is less than that predicted in the laboratory and is much more pronounced with Cr than with Co.
Recurrent patellar dislocation is a relatively common disorder in young patients. Historically, treatment options have been based on the underlying disorder predisposing the patient to the dislocation. This has resulted in various soft tissue reefing procedures, patella tendon realignment procedures and boney realignment procedures. Further research has shown that the medial patello-femoral ligament (MPFL) is the primary restraint to lateral patella subluxation and dislocation. Many authors have published their successful treatment of recurrent patella dislocation by reconstruction of the medial patellofemoral ligament. The most widely used is autologous semitendinosis tendon grafts, as well as synthetic materials, and MPFL reconstructions may be combined with boney procedures. Varieties of fixation techniques have been described involving both the patella and femoral sides. We present a technique of MPFL reconstruction using the autologous ipsilateral quadriceps tendon. Our technique avoids the morbidity associated with semitendinosis graft harvesting and the drill holes in, and potential resulting fracture of, the patella. The technique is also simple and is associated with decreased procedure costs. We present the technique and a series of six patients (seven knees) with follow up ranging from eight months to nine years. The average age of patients at the time of surgery 16 to 28 years (mean = 20 years). There have been no redislocations. The median Kujala patellofemoral knee score at follow up was 97 out of 100 (Range 69–100). The results compare very favorably to published results using other techniques. Our technique of reconstructing the MPFL is reliable, produces good results using an objective knee score, and is cost effective. Seventy staff members participated from a potential pool of approximately one hundred staff on duty at the time. Of the seventy staff who participated in this research project a total of three staff members were within 50 mls of the correct amount for each of the three samples. Overall staff were very poor at estimating blood loss. Staff working in the operating theatre, no matter what their affiliation or years of experience, are not accurate when estimating blood loss spilt into a patients bed. A tool that aids in blood loss estimation is a valuable addition to the theatre resource manual.
Dislocations remain a significant problem, especially after revision hip surgery. Revision of components, particularly in elderly patients with co-morbidities, can be fraught with complications. The surgeon’s options are sometimes restricted, particularly when the acetabular and femoral components are well fixed. Increased head lengths are often utilised to increase tissue tension, and thus improve stability. As a niche solution we have designed a low cost modular femoral neck extender. They are manufactured from medical grade Cobalt-Chrome, conforming to ISO 200, CE mark and EN46001 standards. Available in three incremental lengths and with different connecting Morse tapers, increases in effective neck lengths of up to 49 mms can be achieved. When both the original acetabular and femoral components are well orientated, the resultant increased tissue tension imparts stability to the hip. We present a series of five patients where we have used a femoral neck extender to achieve stability of a total hip replacement. Four patients had had multiple previous dislocations. One patient was unstable at the time of revision surgery because of a high hip centre. The average age of the patients was 72 years, and the number of previous dislocations averaged four. The average follow-up after surgery was 22 months. No patients have redislocated their hips. We present our novel femoral neck extenders as an elegant and cost effective solution to convert an unstable hip to a stable hip, especially when the patient has well fixed and orientated components not in themselves requiring revision.
A randomised prospective study of four bearing surfaces in hip replacements is being conducted. The primary objective is to identify the best long term bearing surf ace clinically and radiographically, and metal ion levels have been measured in all cases. Patients have been randomised to the four bearing surfaces viz. Ceramic-on-XLinked Polyethelene, Ceramic-on-Ceramic, Metal-on-Metal and Ceramic-on-Metal. Pre-operative blood samples and follow-up blood samples for metal ion analysis using ICP-MS method have been taken in all patients. As at February 2008 187 patients have been recruited, and metal ion levels at one year are available in 52 patients. Metal ion levels are not increased with Ceramic-on-XLPE or Ceramic-on-Ceramic bearings. At one year follow-up the metal ion levels in Ceramic-on–Metal bearings is half that of Metal-on-Metal bearings using mean levels, and one third using median levels. Of note is that chromium levels in Ceramic-on-Metal bearings is the least elevated. Due to the laboratory evidence that ceramic-on-metal bearings have the best surf ace wear characteristics with no head stripe wear on a ceramic head, and the laboratory and clinic al evidence of lower metal ion levels, Ceramic-on-Metal hip replacements could be one of the bearing surfaces of the future.
Dislocations remain a significant problem, especially after revision hip surgery. Revision of components, particularly in elderly patients with co-morbidities, can be fraught with complications. The surgeon’s options are sometimes restricted, particularly when the acetabular and femoral components are well fixed. Increased head lengths are often utilized to increase tissue tension, and thus improve stability. As a niche solution we have designed a low cost modular femoral neck extender. They are manufactured from medical grade Cobalt-Chrome, conforming to ISO 200, CE mark and EN46001 standards. Available in 3 incremental lengths and with different connecting Morse tapers, increases in effective neck lengths of up to 49 mm can be achieved. When both the original acetabular and femoral components are well orientated, the resultant increased tissue tension imparts stability to the hip. We present a series of 5 patients where we have used a femoral neck extender to achieve stability of a total hip replacement. 4 patients had had multiple previous dislocations. 1 patient was unstable at the time of revision surgery because of a high hip centre. The average age of the patients was 72 years, and the number of previous dislocations averaged 4. The average follow-up after surgery was 22 months. No patients have redislocated their hips. We present our novel femoral neck extenders as an elegant and cost effective solution to convert an unstable hip to a stable hip, especially when the patient has well fixed and orientated components not in themselves requiring revision.
Recurrent patellar dislocation is a relatively common disorder in young patients. Historically, treatment options have been based on the underlying disorder predisposing the patient to the dislocation. This has resulted in various soft tissue reefing procedures, patella tendon realignment procedures and boney realignment procedures. Further research has shown that the medial patellofemoral ligament (MPFL) is the primary restraint to lateral patella subluxation and dislocation. Many authors have published their successful treatment of recurrent patella dislocation by reconstruction of the medial patellofemoral ligament. The most widely used is autologous semitendinosis tendon grafts, as well as synthetic materials, and MPFL reconstructions may be combined with boney procedures. Varieties of fixation techniques have been described involving both the patella and femoral sides. We present a technique of MPFL reconstruction using the autologous ipsilateral quadriceps tendon. Our technique avoids the morbidity associated with semitendinosis graft harvesting and the drill holes in, and potential resulting fracture of, the patella. The technique is also simple and is associated with decreased procedure costs. We present the technique and a series of 6 patients (7 knees) with follow up ranging from 8 months to 9 years. The average age of patients at the time of surgery 16–28 years (mean = 20years). There have been no redis-locations. The median Kujala patellofemoral knee score at follow up was 97 out of 100 (Range 69–100). The results compare very favourably to published results using other techniques. Our technique of reconstructing the MPFL is reliable, produces good results using an objective knee score, and is cost effective.
Whole blood metal ion levels remain a concern in those patients undergoing total hip replacement with metal bearing surfaces. The determination of baseline reference levels are essential if useful information can be gleaned from in vivo studies of functioning implants. We set out to prospectively determine chromium and cobalt metal ion concentrations in patients undergoing total hip replacement to determine reference levels of these metal ions. 100 patients with normal renal function, no occupational or environmental exposure to cobalt and chromium, and an absence of implanted metals were recruited into the study. Metal ion levels were determined using two different assay methods. Both ICP-MS (Inductively Coupled Plasma Mass Spectroscopy) and GFAAS (Graphite Furnace Atomic Adsorption Spectroscopy) are well recognised analytical techniques for the quantification of trace elements. Levels were correlated with gender, age and place of residence. There was considerable variability in whole blood metal ion levels, with the ICP-MS being more sensitive and consistent than the GFAAS method. Direct comparison of concentration levels determined by the two methods revealed no significant correlation. There was no correlation with age, gender and place of residence. Our findings would favour the use of the ICP-MS to determine reference levels and as a baseline for metalion surveillance pre-operatively in patients undergoing metal-on-metal total hip replacements. We also determined that changes in whole blood metal ion levels are more significant than actual levels in patients who have undergone total hip replacement.
This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 μg/1 and 0.22 μg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 μg/1 and 0.32 μg/1. The chromium levels were significantly lower in CoM than in MoM bearings (p = 0.02). The cobalt levels were lower, but the difference was not significant. Examination of two explanted ceramic heads revealed areas of thin metal transfer. CoM bearings (one explanted head and acetabular component, one explanted head and new acetabular component, and three new heads and acetabular components) were tested in a hip joint simulator. The explanted head and acetabular component had higher bedding-in. However, after one million cycles all the wear rates were the same and an order of magnitude less than that reported for MoM bearings. There were four outliers in each clinical group, primarily related to component malposition.
The search for the ideal bearing surfaces to be used in Total Hip Replacement continues. The current “best” materials are felt to be various combinations of metal, ceramics and cross-linked polyethylene. Laboratory studies suggest that ceramic-on-metal articulations may provide distinct advantages. This study aims to identify the best combination with the lowest side effect profile. In February 2004 a prospective randomised trial on different bearing surfaces was started. The combinations selected were ceramic-on-cross-linked polyethylene, ceramic-on-ceramic, metal-on-metal and ceramic-on-metal. Institutional ethics clearance was obtained. In all patients uncemented femoral stems are used, with an uncemented porocoated acetabular shell. A uniform 28mm femoral head size was selected. Blood samples have been taken to measure the metal ion concentrations in all patients. These are measured pre operatively, and repeated at follow up visits at 3 months and 1 year, with further follow up at 3,5 and 10 years post operatively. Whole blood ion levels are measured using a graphite furnace atomic absorption spectrometer. Between February 2004 and April 2006 one hundred and ten hips have undergone total hip replacement. There are 105 patients (5 bilateral). 40% are males and 60% female. The average age at operation is 52 years (17 to 72). 49% hips are left and 51% right. Follow up includes blood samples and the Harris Hip Score. Complications to date have been surgeon related, with three femoral components needing early revision for technical reasons. This has not affected the bearing surfaces. Radiological and clinical assessment shows no difference between the different bearing surface groups. Post operative whole blood metal ion levels are compared to the patient’s pre operative level. To date there is no increase in the metal ion levels for the ceramic-on-cross linked polyethylene and ceramic-on-ceramic articulations. The ceramic-on-metal group is providing moderately raised metal ion levels, and the highest metal ion levels are in the metal-on-metal articulation group. At one year, the ceramic-on-metal group demonstrates a drop to close to pre-operative levels and these are still significantly lower than the metal-on-metal group. This confirms laboratory studies on the ceramic-on-metal articulation, which demonstrate significantly lower wear than comparable metal-on-metal articulations. The high level of metal ions in the latter groups has always been of concern. This study demonstrates a lower blood level of metal ions in the ceramic-on-metal group. If the in vivo wear rate in this group continues to replicate the laboratory wear studies, this articulation becomes a very attractive bearing surface in younger active patients, and may well become a bearing surface of choice in the future.
The search for the ideal bearing surfaces to be used in Total Hip Replacement continues. The current “best” materials are felt to be various combinations of metal, ceramics and cross linked polyethylene. This study aims to identify the best combination with the lowest side effect profile. In February 2004 a prospective randomised trial on different bearing surfaces was started. The combinations selected were ceramic on cross linked polyethylene, ceramic on ceramic, metal on metal and ceramic on metal. Institutional ethics clearance was obtained. In all patients uncemented femoral stems are used, and an uncemented porocoated acetabular shell. 28mm Head size was selected. Blood samples have been taken to measure the metal ion concentrations in all patients. These are measured pre operatively, and repeated at intended follow up visits at 3 months, 1, 3, 5 and 10 years post operative using a graphite furnace atomic absorption spectrometer. Between February 2004 and 2006 seventy hips have undergone total hip replacement. There are 85 patients (11 bilateral). 40% are males and 60% female. The average age at operation is 52 years (17 to 72). 46% Hips are left and 54% right. Follow up includes blood samples and the Harris Hip Score. Complications to date have been surgeon related, with three femoral components needing early revision for technical reasons. This has not affected the bearing surfaces. Ten patients have hetero-topic ossification. Cup inclination averages at 48 degrees (32 degrees to 69 degrees). Post operative blood metal ion levels are compared to the patient’s pre-operative level. To date there is no increase in the metal ion levels for the ceramic/cross linked poly ethylene and ceramic/ceramic articulations. The ceramic metal group is providing intermediate raised metal ion levels, and the highest metal ion levels are in the metal on metal articulation group. In the laboratory the ceramic on metal articulation demonstrates the least wear of all the groups studied, with metal on metal second. The high level of metal ions in the latter groups has always been of concern. This study demonstrates a lower blood level of metal ions in the ceramic on metal group. If the in vivo wear rate in this group is as good as the laboratory wear, it becomes a very attractive bearing surface in younger active patients.
The aim of this study was to asses the results of total hip replacements using the Elite Plus femoral stem. During the period 1995 to 2000, 212 total hip replacements were done using the Elite Plus femoral stem. These were followed up prospectively. The cohort of patients included 11 with bilateral hip replacements. 38% of patients were male and 62% were female. The average age at surgery was 61 years, with 18% being younger that 50 years at the time of surgery. All hip replacements were done using the same surgical and cementing techniques. Both cemented and uncemented cups were used in this cohort of patients. 2 patients died peri-operatively, and 22 hips were lost to follow-up. 6 hips have been revised, with 1 revision being due to sepsis and 5 due to loosening. A further 4 hips have radiographic evidence of early loosening, and 1 other hip has developed late sepsis. None of these 5 has yet been revised. Our survivorship at an average of 9 years is 97%. The survivorship of total hip replacements using the Elite Plus femoral stem in our unit is 97% at an average of 9 years. This compares very well with the results reported in other series. We do note though that there are 5 hips that may need revision, and this would bring the survivorship down to 94%. We feel that our good results are due to careful attention to surgical and cementing techniques, and this may explain our improved results compared to previous reports.
Good short-term results with Mt Blanc uncemented acetabular cups have been previously reported. However, in the medium term, we have observed acetabular loosening related to large granulomatous lytic lesions. To determine the cause of the polyethylene load causing the granulomatous lytic lesions, we subjected six explanted Mt Blanc acetabular cups to retrieval analysis. We also reviewed the literature on polyethylene locking mechanisms in uncemented metal-backed cups and on the deformability of metal-backed cups. We subjected the retrieved cups to stereo-photographic analysis and to dye penetration and surface scanning electron microscopy techniques. We demonstrated severe polyethylene wear and particle generation on the back surface of the polyethylene insert. This was due both to two-body sliding wear, as characterised by surface deformation and delamination of the polyethylene, and to three-body abrasive wear, as characterised by surface roughness and embedded titanium particles. The literature confirmed that the locking mechanism of the Mt Blanc cup was particularly poor and the deformability greater than in other cups tested. This confirmed the wear patterns on the back-surface of the polyethylene liner. We caution against the use of uncemented cups that have poor locking mechanisms for the polyethylene liners and those that deform excessively. The combination of poor locking mechanisms and titanium shells is especially dangerous.
The aim of this study was to measure polyethylene wear in uncemented metal-backed cups and compare it with cemented ultra-high molecular weight (UHMW) polyethylene cups in a controlled double-blind study. The study group was made up of 91 patients aged 50 to 70 years undergoing THR for unilateral OA of the hip between February 1995 and July 2002. The male to female ratio was 40:60. In all patients, a cemented stem and 28-mm ceramic head was inserted, using a third-generation cementing technique and UHMW polyethylene. Patients were randomly allocated to receive either a cemented or uncemented acetabular cup. Eight patients were lost to follow-up. Cemented cups were used in 28 patients (mean age 64 years). The mean thickness of the polyethylene was 9.6 mm (7.5 to 12.5). The mean liner thickness in the metal-backed cups was 8.9 mm (7 to 12.2). In measuring wear, baseline 3-month postoperative radiographs were compared with the most recent follow-up radiographs and Martell software was used. The polyethylene in metal-backed cups had a mean wear rate of 0.49 mm at 4.7 years, with a mean annual wear rate of 0.12 mm. The cemented polyethylene cups had a mean wear rate of 0.45 mm at 5.3 years, with a mean annual wear rate of 0.11 mm. The study is ongoing. Currently we conclude that there is no significant difference in the annual wear rate of polyethylene in uncemented metal-backed cups and cemented cups.
Osteolysis and subsequent mechanical loosening often occurs in hip arthroplasties using polyethylene-on-ceramic (POC) bearings. This has prompted an ongoing search for alternative bearing surfaces. Ceramic-on-ceramic (COC) and metal-on-metal (MOM) prostheses are widely used, with good clinical results. Using hip simulator studies, we compared ceramic-on-metal (COM) and MOM prostheses. We found COM pairings had 100-fold lower wear rates than MOM. The wear particles from both articulations were oval to round in shape and in the nanometer size range, with the COM producing smaller particles than the MOM. In both pairings, particle size decreased as the bearings bedded in. The volumetric particle loads were far smaller with COM bearing-surfaces than in currently-used MOM prostheses. These findings have encouraged us to investigate the use of these novel bearing surfaces. Ethical approval has been obtained, and a prospective randomised clinical trial comparing POC, MOM, COC and COM bearing surfaces has started.
The assessment of large allografts in acetabular reconstruction surgery is notoriously difficult. Because of their invasive natures, methods such as tetracycline-labeled histological examination are not recommended. Radio-isotope studies are unreliable in assessing the degree of incorporation because labeled tissues remain hot for extended periods. CT scans are impractical because of the scatter generated by the metallic prosthetic components. We used DEXA to assess the quality of large acetabular bone grafts immediately after surgery and at regular intervals thereafter. Software programmes were used to subtract the prosthetic components and give values for the remaining bony structure. DEXA results confirmed the initial adequacy of our grafting techniques. Serial scans showed the response of the grafts to both revascularisation and loading. Increases in high-load areas were higher than in low-load areas, reflecting the response of live bone to in vivo stresses. There were also changes reflecting the ongoing revascularisation of the grafts. These findings were born out by radiographs. DEXA is useful in assessing the incorporation and biological responses of large allografts in revision arthroplasty.
Over five years, 85 low-cost primary total arthroplasties (Eortopal Bulteamex) were done at a referral hospital. These were followed up for a mean of 48 months (minimum of 18 months). There were 11 revisions (13%), with four (4.7%) necessary for aseptic loosening, two (2.3%) for recurrent dislocations, four (4.7%) for sepsis and one (1.3%) for a periprosthetic fracture. When these results were compared with the Trent Regional Arthroplasty Register, the revision rate was noted to be four times higher than in the Trent study, with aseptic revisions being twice as high and infection rates three times higher. Dislocation rates were half those in the Trent study. We concluded that our lower dislocation rate probably reflected the quality of our surgery. Our higher sepsis rate was probably related to the hospital environment, and the high aseptic loosening rate due to the quality of the ‘low-cost’ prosthesis. We conclude that to be cost-efficient, ‘low-cost’ pros-theses must be of good quality and that the hospital environment must be optimal. This study highlights the need for an Arthroplasty Register in South Africa.
Four low-cost hip prostheses, explanted because of clinical failure within three years, were subjected to a retrieval analysis study to determine the cause of the early failure. The study aimed to determine whether the low-cost prosthesis was substandard and had consequently contributed to the need for early revision. The retrieval analysis included a photographic record, a fractographic examination, an analysis of the material composition of the components, and a mechanical property analysis. These investigations were done in accordance with the ASTM F561 standards. Results demonstrated substandard qualities in respect of all parameters analysed. We conclude that the inferior quality of these low-cost hip prostheses contributed appreciably to their early failure and revision.
We have previously reported on early lytic lesions occurring when collared titanium prostheses are used. Previous finite element analysis studies (FEAs) showed that lytic lesions of the calcar were due to concentration of polyethylene wear particles under the collar by a ‘pumping action’. Further follow-up of these calcar lytic lesions showed that their rate of increase in size progressively slowed down. Further FEAs were performed to determine why this was so. An FEA mesh construct was developed, incorporating the new parameters of no contact between the collar and the calcar bone. A mechanical model to determine displacement parameters was also developed. These FEA studies demonstrated that the pumping action of the collar became less efficient as the size of the lytic lesions increased. This led to less concentration of polyethylene particles under the collar and fewer granulomatous reactions. The change in the proximal prosthesis-cement-bone construct may lead to cement mantle deterioration and earlier failure. We still recommend caution when a collared prosthesis is used, and the material and geometry of the prosthesis remain important.
Complex acetabular defects after failed total hip arthroplasty (THA) remain a major challenge in revision surgery. We managed 29 patients, of whom 27 had type-III and two type-IV defects (AAOS classification).The mean age of the 16 men and 13 women was 68 years (22 to 96). Use of a modular uncemented acetabular revision system allowed us accurately to position the construct, and then optimise the orientation of the polyethylene liner in respect of stability in the reduced hip. The modularity of the system allowed good access to do an impaction bone graft to restore the defects in the bone stock. Our follow-up ranged from 2 to 25 months. The orientation of the acetabular construct was measured radiologically and was at 50°. Our complications included four dislocations, two transient nerve palsies, one deep infection, four deep venous thromboses and one death from a pulmonary embolism. We conclude that the use of a modular acetabular reconstruction system is promising in these extremely difficult cases.
We managed three elderly patients who had central fracture dislocations with early total hip arthroplasty (THA), using anteprotrusio supports. Bone grafting was used to re-establish acetabular bone stock. Intraoperatively and postoperatively, these patients had no more complications than did patients undergoing THA for hip fractures. However, the surgical times were longer than for routine THA and blood replacement was slightly higher. Patients were mobilised early and aggressively. All became independent walkers and regained good range of movement. Radiologically the acetabular/pelvic fractures united and good bone-implant interfaces were established. There was no excessive heterotrophic bone formation. We regard THA in the management of acetabular fractures in the elderly as a reasonable approach, enabling patients to mobilise early and keeping morbidity to an acceptable level.
In June 1999 we instituted a prospective, randomised, double blind study to determine whether in the use of the Profix® total knee replacement system the addition of screws improved the fixation of the tibial base plate. There were 145 arthroplasties in 137 patients, 77% of them female. Their mean age was 66 years. In 86% of the patients there was osteoarthritis and in 14% an inflammatory arthritis. On a random basis, supplementary screws were inserted through the base plate into the tibia in 49% of arthroplasties and the remaining 51% were not fixed. In both groups the postoperative femoral angle measured 95% and at 12-month evaluation the tibial angle measured 89°, giving a total valgus angle of 6°. To date no tibial base plates have come loose. It is felt that the large central titanium peg plays a major role in assisting fixation of the base plate to the tibia and that supplementary screws are unnecessary. There is a small cost saving when screws are not used. We postulate that one may in the future minimise polyethylene debris tracking and osteolysis.
Anterior knee pain after total knee arthroplasty (TKA) occurs in 5% to 30% of patients whether or not the patella has been resurfaced. We retrospectively reviewed our patients, none of whom underwent patellar resurfacing. Only 2% had anterior knee pain, none requiring revision surgery. Our follow-up was between two and five years. We paid particular attention to removing osteophytes and conducting a thorough peripatellar synovectomy and a circumpatellar cautery denervation. Our results compare favourably to those in the literature, whether or not the patellae were resurfaced. We conclude that patellar resurfacing in TKA is unnecessary when careful attention is paid to the peripatellar tissues.
Complex acetabular defects after failed total hip arthroplasty (THA) remain a major challenge in revision surgery. We managed 29 patients, of whom 27 had type-III and two type-IV defects (AAOS classification). The mean age of the 16 men and 13 women was 68 years (22 to 96). Use of a modular uncemented acetabular revision system allowed us accurately to position the construct, and then optimise the orientation of the polyethylene liner in respect of stability in the reduced hip. The modularity of the system allowed good access to do an impaction bone graft to restore the defects in the bone stock. Our follow-up ranged from 2 to 25 months. The orientation of the acetabular construct was measured radiologically and was at 50°. Our complications included four dislocations, two transient nerve palsies, one deep infection, four deep vein thromboses and one death from pulmonary embolism. We conclude that the use of a modular acetabular reconstruction system is promising in these extremely difficult cases.
Resorption of the calcar below the collar of a titanium femoral prosthesis was observed. Biopsies of these lesions showed concentrations of polyethylene. We assessed the size of the resorption and correlated this with the size of the femoral prosthesis and the time since implantation. The age and the weight of the patient were also linked to the size of the prosthesis. We conducted a finite element analysis (FEA) of the femoral component-femur complex in both the loaded and unloaded situation. The FEA study demonstrated changing pressure under the collar that can be translated into microbending motions, with the degree of the movement dependent on the size of the prosthesis, the material of the prosthesis and the weight of the patient. We hypothesise that the existence of a ‘polyethylene pump’ due to the bending movements of the collared prosthesis concentrates polyethylene particles under the collar. We therefore postulated that the calcar resorption is due to the polyethylene granulomatous lesions, resulting from the micromotion of the collar of the prosthesis.
We have introduced a radiological scoring system to assess our technical competence in hip replacement surgery. We have also used it to assess the progress of the registrars in our training programme. This scoring method involves several parameters, including positioning of the components and the quality of interfaces. We compared our results before and after the introduction of this scoring system, and found that the quality of our surgery had improved. We conclude that an objective scoring system is valuable as a training aid, as well as in maintaining standards in our unit.
Over five years, 85 low-cost primary total arthroplasties (Eortopal Bulteamex) were done at a referral hospital. These were followed up for a mean of 48 months (minimum of 18 months). There were 11 revisions (13%), with four (4.7%) necessary for aseptic loosening, two (2.3%) for recurrent dislocations, four (4.7%) for sepsis and one (1.3%) for a periprosthetic fracture. When these results were compared with the Trent Regional Arthroplasty Register, the revision rate was noted to be four times higher than in the Trent study, with aseptic revisions being twice as high and infection rates three times higher. Dislocation rates were half those in the Trent study. We concluded that our lower dislocation rate probably reflected the quality of our surgery. Our higher sepsis rate was probably related to the hospital environment, and the high aseptic loosening rate due to the quality of the ‘low-cost’ prosthesis. We conclude that to be cost-efficient, ‘low-cost’ prostheses must be of good quality and that the hospital environment must be optimal. This study highlights the need for an Arthroplasty Register in South Africa.
Severe central facture dislocations of the hip in the elderly can be catastrophic. Conservative treatment yields poor results with stiff painful hips. Reasonable hip function may be achieved with multiple surgical procedures and extended periods of immobilisation, but morbidity and mortality remain high. We managed three elderly patients who had central fracture dislocations with early total hip arthroplasty (THA), using anteprotrusio supports. Bone grafting was used to re-establish acetabular bone stock. Intraoperatively and postoperatively, these patients had no more complications than did patients undergoing THA for hip fractures. However, the surgical times were longer than for routine THA and blood replacement was slightly higher. Patients were mobilised early and aggressively. All became independent walkers and regained good range of movement. Radiologically the acetabular/pelvic fractures united and good bone-implant interfaces were established. There was no excessive heterotrophic bone formation. We regard THA in the management of acetabular fractures in the elderly as a reasonable approach, enabling patients to mobilise early and keeping morbidity to an acceptable level.
In June 1999 a randomised double-blind study on tibial base plate fixation was started to determine whether, when using the Profix® total knee replacement, the addition of screws improved the fixation of the tibial base plate. To date 138 total knee arthroplasties (THAs) have been performed, 119 of which were available for study. Selected randomly, 56 patients had supplementary screws inserted through the base plate and 63 did not. After a minimum of 12 months follow-up, 27 patients had some radiolucent lines at the prosthesis-bone interface on the tibial component. These lines occurred in 14 cases with supplementary screws and 13 without screws. In one patient without supplementary screws, the tibial tray had subsided into the tibia. Statistically there was no apparent difference between the two groups. The early results of our study raise questions about the value of supplementing base plate fixation in uncemented THAs, especially considering the additional cost of the screws and their potentially detrimental consequences.
Primary total hip replacements are routine procedures with good outcomes. To ensure uniformly good results it is important that a thorough preoperative assessment of the patient is made. The prosthesis best suited to the patient and the pathology must be carefully selected and the optimal surgical technique must take into account patient, pathology and prosthesis parameters. We discuss patients’ problems such as morbid obesity, the different arthritides and neuromotor abnormalities. Acetabular problems, including dysplastic acetabula and acetabula protrusio, are dealt with in detail. We examine post-traumatic hip pathologies, including retained fracture implants, nonunions and ankyloses. On the femoral side, dysplastic femurs, post-traumatic malunions and post-osteotomies are dealt with.