header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 141 - 141
2 Jan 2024
Wendlandt R Volpert T Schroeter J Schulz A Paech A
Full Access

Gait analysis is an indispensable tool for scientific assessment and treatment of individuals whose ability to walk is impaired. The high cost of installation and operation are a major limitation for wide-spread use in clinical routine.

Advances in Artificial Intelligence (AI) could significantly reduce the required instrumentation. A mobile phone could be all equipment necessary for 3D gait analysis. MediaPipe Pose provided by Google Research is such a Machine Learning approach for human body tracking from monocular RGB video frames that is detecting 3D-landmarks of the human body.

Aim of this study was to analyze the accuracy of gait phase detection based on the joint landmarks identified by the AI system.

Motion data from 10 healthy volunteers walking on a treadmill with a fixed speed of 4.5km/h (Callis, Sprintex, Germany) was sampled with a mobile phone (iPhone SE 2nd Generation, Apple). The video was processed with Mediapipe Pose (Version 0.9.1.0) using custom python software. Gait phases (Initial Contact - IC and Toe Off - TO) were detected from the angular velocities of the lower legs. For the determination of ground truth, the movement was simultaneously recorded with the AS-200 System (LaiTronic GmbH, Innsbruck, Austria).

The number of detected strides, the error in IC detection and stance phase duration was calculated.

In total, 1692 strides were detected from the reference system during the trials from which the AI-system identified 679 strides. The absolute mean error (AME) in IC detection was 39.3 ± 36.6 ms while the AME for stance duration was 187.6 ± 140 ms.

Landmark detection is a challenging task for the AI-system as can clearly be seen be the rate of only 40% detected strides. As mentioned by Fadillioglu et al., error in TO-detection is higher than in IC-detection.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 38 - 38
2 Jan 2024
Frese J Schulz A Kowald B Gerlach U Frosch K Schoop R
Full Access

In a consecutive retrospective analysis of 190 patients treated with the Masquelet technique at the BG Klinikum Hamburg from January 2012 to January 2022, defect-specific features such as the extent and morphology of the defect were recorded, and their influence on the time to reach full weight-bearing of the affected limb was investigated.

A total of 217 defects were treated in 190 patients using the Masquelet technique. 70% of all defects were located in the tibia, followed by 22% in the femur and only about 7% in the upper extremity. The average length of all defects was 58 mm (+/−31 mm), with the largest defect measuring 180 mm and the smallest measuring 20 mm. 89% of the patients achieved full weight-bearing at the end of therapy. The average time from initiation of therapy to reaching safe full weight-bearing was 589 days. There was a significant correlation between defect length and time to reach full weight-bearing (p = 0.0134). These results could serve as a basis for creating a score for prognostics and evaluation of bone healing after treatment with the Masquelet technique. Additionally, the results could help guide indications for secondary stabilization using internal fixation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 20 - 20
17 Apr 2023
Reimers N Huynh T Schulz A
Full Access

The objectives of this study are to evaluate the impact of the CoVID-19 pandemic on the development of relevant emerging digital healthcare trends and to explore which digital healthcare trend does the health industry need most to support HCPs.

A web survey using 39 questions facilitating Five-Point Likert scales was performed from 1.8.2020 – 31.10.2020. Of 260 participants invited, 90 participants answered the questionnaire. The participants were located in the Hospital/HCP sector in 11.9%, in other healthcare sectors in 22.2%, in the pharmaceutical sector in 11.1%, in the medical device and equipment industry in 43.3%. The Five-Point Likert scales were in all cases fashioned as from 1 (strongly disagree) to 5 (strongly agree).

As the top 3 most impacted digital health care trends strongly impacted by CoVID-19, respondents named:

- remote management of patients by telemedicine, mean answer 4.44

- shared data governance under patient control, mean answer 3.80

- new virtual interaction between HCP´s and medical industry, mean answer 3.76

Respondents were asked which level of readiness of the healthcare system currently possess to cope with the current trend impacted by CoVID-19.

- Digital and efficient healthcare logistics, mean answer 1.54

- Integrated health care, mean answer 1.73

- Use of big data and artificial intelligence, mean answer 2.03

Asked if collaborative research in the form of digital data platforms for research data sharing and increasing collaboration with multi-centric consortia would have a positive impact on the healthcare sector, the agreement was high with a value of mean 4.10 on the scale.

We can conclude that the impact of COVID-19 appears to be a high agreement of necessary advances in digitalization in the health care sector and in the collaboration of HCPs with the health care industry. Health care professional are unsure, in how far the national health care sector is capable of transformation in healthcare logistics and integrated health care.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 19 - 19
17 Apr 2023
Niessen L Wendlandt R Schulz A
Full Access

A promising application of Mesenchymal stem cells (MSCs) is the treatment of non-unions. Substituting bone grafts, MSCs are directly injected into the fracture gap. High cell viability seems to be a prerequisite for therapeutic success. Administration of the MSCs via injection creates shear stresses possibly damaging or destroying the cells.

Aim of this study was to investigate the effect of the injection process on cell viability.

MSCs were isolated and cultivated from femoral tissue of five subjects undergoing arthroplasty. Prior to injection, the cells were identified as MSCs. After dissolving to a concentration of 1 Million cells/ml, 1 ml of the suspension was injected through a cannula of 200 mm length and 2 mm diameter (14 G) with flow rates of 38 and 100 ml/min. The viability of the MSCs at different flow rates was evaluated by staining to detect the healthy cell fraction. It was analyzed statistically against a control group via the Kruskal-Wallis-test and for equivalence via the TOST procedure. Significance level was set to 5 %, equivalence margin to 20 %.

The healthy cell fraction of the control group was 85.88 ± 2.98 %, 86.04 ± 2.53 % at 38 ml/min and 85.48 ± 1.64 % at 100 ml/min. There was no significant difference between the fraction of healthy cells (p = 0.99) for different volume flows, but a significant equivalence between the control group and the two volume flows (38 ml/min: p = 0.002, 100 ml/min: p = 0.001).

When injecting MSC solutions, e.g. into a non-union, the viability of the injected cells does not deterioriate significant. The injecting technique is therefore feasible.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 61 - 61
11 Apr 2023
Wendlandt R Herchenröder M Hinz N Freitag M Schulz A
Full Access

Vacuum orthoses are being applied in the care of patients with foot and lower leg conditions, as ankle fractures or sprains. The lower leg is protected and immobilized, which increases mobility. Due to the design, the orthoses lead to a difference in leg length, i.e. the side with the orthosis becomes longer, which changes the gait kinematics. To prevent or mitigate the unfavourable effects of altered gait kinematics, leg length-evening devices (shoe lifts) are offered that are worn under the shoe on the healthy side. Our aim was to evaluate the effect of such a device on the normality of gait kinematics.

Gait analysis was conducted with 63 adult, healthy volunteers having signed an informed consent form that were asked to walk on a treadmill at a speed of 4.5km/h in three different conditions:

barefoot - as reference for establishing the normality score baseline

with a vacuum orthosis (VACOPed, OPED GmbH, Germany) and a sport shoe

with a vacuum orthosis and a shoe lift (EVENup, OPED GmbH, Germany)

Data was sampled using the gait analysis system MCU 200 (LaiTronic GmbH, Austria). The positions of the joint markers were exported from the software and evaluated for the joint angles during the gait cycle using custom software (implemented in DIAdem 2017, National Instruments).

A normality score using a modification of the Gait Profile Score (GPS) was calculated in every 1%-interval of the gait cycle and evaluated with a Wilcoxon signed rank test.

The GPS value was reduced by 0.33° (0.66°) (median and IQR) while wearing the shoe lift. The effect was statistically significant, and very large (W = 1535.00, p < .001; r (rank biserial) = 0.52, 95% CI [0.29, 0.70]).

The significant reduction of the GPS value indicates a more normal gait kinematics while using the leg length-evening device on the contralateral shoe. This rather simple and inexpensive device thus might improve patient comfort and balance while using the vacuum orthoses.