header advert
Results 1 - 50 of 124
Results per page:
The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 203 - 211
1 Feb 2024
Park JH Won J Kim H Kim Y Kim S Han I

Aims

This study aimed to compare the performance of survival prediction models for bone metastases of the extremities (BM-E) with pathological fractures in an Asian cohort, and investigate patient characteristics associated with survival.

Methods

This retrospective cohort study included 469 patients, who underwent surgery for BM-E between January 2009 and March 2022 at a tertiary hospital in South Korea. Postoperative survival was calculated using the PATHFx3.0, SPRING13, OPTIModel, SORG, and IOR models. Model performance was assessed with area under the curve (AUC), calibration curve, Brier score, and decision curve analysis. Cox regression analyses were performed to evaluate the factors contributing to survival.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 126 - 126
11 Apr 2023
Kim Y Choi Y Cho S
Full Access

Chronic lateral ankle instability (CLAI) is treated operatively, whereas acute ligament injury is usually treated nonoperatively. Such treatments have been widely validated. Apoptosis is known to cause ligament degeneration; however, few reports have focused on the possible role of apoptosis in degeneration of ruptured lateral ankle ligaments. The aim of our study is to elucidate the apoptosis that occurs within anterior talofibular ligament (ATFL) to further validate current CLAI treatments by adducing molecular and cellular evidence.

Between March 2019 and February 2021, 50 patients were prospectively enrolled in this study. Ruptured ATFL tissues were collected from 21 CLAI patients (group C) and 17 acute ankle fracture patients (group A). Apoptotic cells were counted using the terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end-labeling (TUNEL) assay. Western blotting for caspases 3, 7, 8, and 9 and cytochrome c, was performed to explore intrinsic and extrinsic apoptotic pathways. Immunohistochemistry was used to detect caspases 3, 7, 8, and 9 and cytochrome c, in ligament vessel endothelial cells.

More apoptotic cells were observed in group C than group A in TUNEL assay. Western blotting revealed that the apoptotic activities of group C ligaments were significantly higher than those of group A (all p < 0.001). Immunohistochemistry revealed increased expression of caspases 3, 7, 8, and 9, and cytochrome c, in group C compared to group A.

The ATFL apoptotic activities of CLAI patients were significantly higher than those of acute ankle fracture patients, as revealed biochemically and histologically. Our data further validate current CLAI treatments from a molecular and cellular perspective. Efforts should be made to reverse or prevent ATFL apoptosis in CLAI patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 54 - 54
4 Apr 2023
Kim Y Yang H Bae H Han H
Full Access

Stem cells are known to have low levels of intracellular reactive oxygen species (ROS) and high levels of glutathione. ROS are thought to interact with several pathways that affect the transcription machinery required for stem cell differentiation, and are critical for maintaining stem cell function. In this study, we are developing a new fluorescent probe that rapidly and reversibly reacts with glutathione (GSH), the most abundant non-protein thiol in living cells that acts as an antioxidant and redox regulator.

Multipotent perivascular progenitor cells derived from human ESCs (hESC-PVPCs): Differentiated ESCs as embryoid bodies in the presence of BMP4 to induce mesoderm differentiation followed by a simple cell selection strategy using attachment of single cells onto collagen-coated dishes. Differential gene expression profiling was performed among H9 hESCs, EBs induced by BMP4 and naturally selected CD140B+CD44+ population at Day 7 (PVPCs). Colony-forming assay: GSHhigh and GSHlow PVPCs were plated on 10-cm tissue culture-treated polystyrene dishes in triplicate in growth medium and cultured for 14 days. Transwell migration assay: GSHhigh and GSHlow PVPCs at passage 4 were resuspended at 1 × 106/mL in the migration medium and seeded in the upper chamber. The following human recombinant SDF-1 and PDGF-AA proteins were used as chemoattractants in the lower compartment.

Probe-GSH conjugate shows shifts in fluorescence excitation and emission spectra that enables ratiometric measurement of GSH levels. Using these properties, stem cells can be purified by FACS-based technology according to intracellular GSH level. We are developing a protocol both for comparing GSH level in stem cell from different culture conditions and for preparing stem cells with high-GSH level . Our results reveal that GSHhigh PVPC purified by FACS show increased colony forming ability compared with that GSHlow PVPC, indicating that intracellular GSH contributes to the maintenance of stemness. Moreover, transplantation of GSHlow PVPC is more effective than that of GSHlow PVPC for cartilage regeneration in osteochondral defect.

This technique enable FACS-based sorting of stem cells according to intracellular GSH levels and thus investigation of functional role of GSH (high antioxidant capacity) in the stem cell maintenance and chondrogenic differentiation.


Bone & Joint Research
Vol. 12, Issue 1 | Pages 22 - 32
11 Jan 2023
Boschung A Faulhaber S Kiapour A Kim Y Novais EN Steppacher SD Tannast M Lerch TD

Aims

Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients.

Methods

A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method).


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1017 - 1024
1 Sep 2022
Morris WZ Justo PGS Williams KA Kim Y Millis MB Novais EN

Aims

The aims of this study were to characterize the incidence and risk factors associated with stress fractures following periacetabular osteotomy, and to determine their effect on osteotomy union.

Methods

We retrospectively reviewed all periacetabular osteotomies (PAOs) performed for developmental dysplasia of the hip (DDH) at one institution over a six-year period between 2012 and 2017. Perioperative factors were recorded, and included demographic and surgical data. Postoperatively, patients were followed for a minimum of one year with anteroposterior and false profile radiographs of the pelvis to monitor for evidence of stress fracture and union of osteotomies. We characterized the incidence and locations of stress fractures, and used univariate and multivariable analysis to identify factors predictive of stress fracture and the association of stress fracture on osteotomy union.


The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1380 - 1385
2 Aug 2021
Kim Y Ryu J Kim JK Al-Dhafer BAA Shin YH

Aims

The aim of this study was to assess arthritis of the basal joint of the thumb quantitatively using bone single-photon emission CT/CT (SPECT/CT) and evaluate its relationship with patients’ pain and function.

Methods

We retrospectively reviewed 30 patients (53 hands) with symptomatic basal joint arthritis of the thumb between April 2019 and March 2020. Visual analogue scale (VAS) scores for pain, grip strength, and pinch power of both hands and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores were recorded for all patients. Basal joint arthritis was classified according to the modified Eaton-Glickel stage using routine radiographs and the CT scans of SPECT/CT, respectively. The maximum standardized uptake value (SUVmax) from SPECT/CT was measured in the four peritrapezial joints and the highest uptake was used for analysis.


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1194 - 1199
14 Sep 2020
Lee H Kim E Kim Y

Aims

The purpose of this study was to identify the changes in untreated long head of the biceps brachii tendon (LHBT) after a rotator cuff tear and to evaluate the factors related to the changes.

Methods

A cohort of 162 patients who underwent isolated supraspinatus with the preservation of LHBT was enrolled and evaluated. The cross-sectional area (CSA) of the LHBT on MRI was measured in the bicipital groove, and preoperative to postoperative difference was calculated at least 12 months postoperatively. Second, postoperative changes in the LHBT including intratendinous signal change, rupture, dislocation, or superior labral lesions were evaluated with seeking of factors that were correlated with the changes or newly developed lesions after rotator cuff repair.


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 772 - 778
1 Jun 2020
Kim Y Jang WY Park JW Park YK Cho HS Han I Kim H

Aims

For paediatric and adolescent patients with growth potential, preservation of the physiological joint by transepiphyseal resection (TER) of the femur confers definite advantages over arthroplasty procedures. We hypothesized that the extent of the tumour and changes in its extent after neoadjuvant chemotherapy are essential factors in the selection of this procedure, and can be assessed with MRI. The oncological and functional outcomes of the procedure were reviewed to confirm its safety and efficacy.

Methods

We retrospectively reviewed 16 patients (seven male and nine female, mean age 12.2 years (7 to 16)) with osteosarcoma of the knee who had been treated by TER. We evaluated the MRI scans before and after neoadjuvant chemotherapy for all patients to assess the extent of the disease and the response to treatment.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 52 - 52
1 Feb 2020
Lazennec J Kim Y Caron R Folinais D Pour AE
Full Access

Introduction

Most of studies on Total Hip Arthroplasty (THA) are focused on acetabular cup orientation. Even though the literature suggests that femoral anteversion and combined anteversion have a clinical impact on THA stability, there are not many reports on these parameters. Combined anteversion can be considered morphologically as the addition of anatomical acetabular and femoral anteversions (Anatomical Combined Anatomical Anteversion ACA). It is also possible to evaluate the Combined Functional Anteversion (CFA) generated by the relative functional position of femoral and acetabular implants while standing. This preliminary study is focused on the comparison of the anatomical and functional data in asymptomatic THA patients.

Material and methods

50 asymptomatic unilateral THA patients (21 short stems and 29 standard stems) have been enrolled. All patients underwent an EOS low dose evaluation in standing position.

SterEOS software was used for the 3D measurements of cup and femur orientation. Cup anatomical anteversion (CAA) was computed as the cup anteversion in axial plane perpendicular to the Anterior Pelvic Plane. Femoral anatomical anteversion (FAA) was computed as the angle between the femoral neck axis and the posterior femoral condyles in a plane perpendicular to femoral mechanical axis. Functional anteversions for the cup (CFA) and femur (FFA) were measured in the horizontal axial patient plane in standing position. Both anatomical and functional cumulative anteversions were calculated as a sum. All 3D measures were evaluated and compared for the repeatability and reproducibility

Statistical analysis used Mann-Whitney U-test considering the non-normal distribution of data and the short number of patients (<30 for each group).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 34 - 34
1 Feb 2020
Kim Y Pour AE Lazennec J
Full Access

Purpose

Minimally invasive anterolateral approach (ALA) for total hip arthroplasty (THA) has gained popularity in recent years as better postoperative functional recovery and lower risk of postoperative dislocation are claimed. However, difficulties for femur exposure and intraoperative complications during femoral canal preparation and component placement have been reported. This study analyzes the anatomical factors likely to be related with intraoperative complications and the difficulties of access noted by the surgeons through a modified minimally invasive ALA. The aim is to define the profile for patient at risk of intraoperative complications during minimally invasive ALA.

Methods

We retrospectively included 310 consecutive patients (100 males, 210 females) who had primary unilateral THA using the same technique in all cases. The approach was performed between the tensor fascia lata and the gluteus medius and minimus, without incising or detaching muscles and tendons. Posterior translation was combined to external rotation for proximal femur exposure (Fig. 1). All patients were reviewed clinically and radiologically. For the radiological evaluation, all patients underwent pre- and postoperative standing and sitting full-body EOS acquisitions. Pelvic [Sacral slope, Pelvic incidence (PI), Anterior pelvic plane angle] and femoral parameters were measured preoperatively. We assessed all intraoperative and postoperative complications for femoral preparation and implantation. Intraoperative complications included the femoral fractures and difficulties for femoral exposure (limitations for exposure and lateralization of the proximal femur). The patients were divided into two groups: patients with or without intraoperative complications.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 146 - 146
1 Feb 2020
King C Chakour K Kim Y Luu H Martell J
Full Access

Introduction

Background: Trochanteric bursitis is a common and poorly understood complication following total hip arthroplasty (THA). The purpose of this study was to evaluate the incidence of symptomatic trochanteric bursitis and the change in hip offset among THA patients before and after the introduction of robotic assistance.

Methods

Retrospective chart review of THAs performed by a single over a 3-year period between 1/5/2013 and 6/28/2016. Between 1/5/2013 and 11/11/2014 101 consecutive patients were identified that underwent manual posterior-lateral THA that utilized traditional cup positioning method based on AP Pelvis radiograph. The subsequent six-month period during a complete transition to robotic arm assistance for posterior-lateral THA was excluded to eliminate any learning curve or selection bias. Between 6/2015 and 6/2016 109 consecutive patients that underwent robotic arm-assisted. Medical records were reviewed for symptomatic trochanteric bursitis within two years of surgery. Hip offset was measured on preoperative and postoperative AP pelvis radiographs and postoperative joint reactive forces were calculated using Martell's Hip Analysis Suite.


Introduction

Limb-length discrepancy (LLD) is a common postoperative complication after total hip arthroplasty (THA). This study focuses on the correlation between patients’ perception of LLD after THA and the anatomical and functional leg length, pelvic and knee alignments and foot height. Previous publications have explored this topic in patients without significant spinal pathology or previous spine or lower extremity surgery. The objective of this work is to verify if the results are the same in case of stiff or fused spine.

Methods

170 patients with stiff spine (less than 10° L1-S1 lordosis variation between standing and sitting) were evaluated minimum 1 year after unilateral primary THA implantation using EOS® images in standing position (46/170 had previous lumbar fusion). We excluded cases with previous lower limbs surgery or frontal and sagittal spinal imbalance. 3D measures were performed to evaluate femoral and tibial length, femoral offset, pelvic obliquity, hip-knee-ankle angle (HKA), knee flexion/hyperextension angle, tibial and femoral rotation.

Axial pelvic rotation was measured as the angle between the line through the centers of the hips and the EOS x-ray beam source. The distance between middle of the tibial plafond and the ground was used to investigate the height of the foot.

For data with normal distribution, paired Student's t-test and independent sample t-test were used for analysis. Univariate logistic regression was used to determine the correlation between the perception of limb length discrepancy and different variables. Multiple logistic regression was used to investigate the correlation between the patient perception of LLD and variables found significant in the univariate analysis. Significance level was set at 0.05.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 8 - 8
1 Feb 2020
Lazennec J Kim Y Folinais D Pour AE
Full Access

Introduction

Post op cup anatomical and functional orientation is a key point in THP patients regarding instability and wear. Recently literature has been focused on the consequences of the transition from standing to sitting regarding anteversion, frontal and sagittal inclination. Pelvic incidence (PI) is now considered as a key parameter for the analysis of sagittal balance and sacral slope (SS) orientation. It's influence on THP biomechanics has been suggested. Interestingly, the potential impact of this morphological angle on cup implantation during surgery and the side effects on post op functional orientation have not been studied.

Our study explores this topic from a series of standing and sitting post-op EOS images

Material and methods

310 patients (mean age 63,8, mean BMI 30,2) have been included prospectively in our current post-operative EOS protocol. All patients were operated with the same implants and technique using anterior approach in lateral decubitus.

According to previous literature, 3 groups were defined: low PI less than 45° (57 cases), high PI if more than 60° (63 cases), and standard PI in 190 other cases.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 317 - 324
1 Mar 2019
Moon J Kim Y Hwang K Yang J Ryu J Kim Y

Aims

The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA).

Patients and Methods

A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 303 - 310
1 Mar 2019
Kim S Lim Y Kwon S Jo W Heu J Kim Y

Aims

The purpose of this study was to examine whether leg-length discrepancy (LLD) following unilateral total hip arthroplasty (THA) affects the incidence of contralateral head collapse and subsequent THA in patients with bilateral osteonecrosis, and to determine factors associated with subsequent collapse.

Patients and Methods

We identified 121 patients with bilateral non-traumatic osteonecrosis who underwent THA between 2003 and 2011 to treat a symptomatic hip, and who also exhibited medium-to-large lesions (necrotic area ≥ 30%) in an otherwise asymptomatic non-operated hip. Of the 121 patients, 71 were male (59%) and 50 were female (41%), with a mean age of 51 years (19 to 71) at the time of initial THA. All patients were followed for at least five years and were assessed according to the presence of a LLD (non-LLD vs LLD group), as well as the LLD type (longer non-operated side vs shorter non-operated side group).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 12 - 12
1 Apr 2018
Lazennec J Kim Y Pour AE
Full Access

Introduction

Few studies are published about total hip arthroplasties (THA) in Parkinson's disease as it is often considered as a contraindication for hip replacement. THA for fracture is reported as a high complication rate surgery. Regarding bone quality these cases are assimilated to elderly patients and cemented implants are generally preferred. However, due to the improved length and quality of life, we face more potential indications for joint replacement. The aim of this study is to report our experience of cementless dual mobility implants for primary THAs for osteoarthrosis and THA revisions focusing on the risks and benefits of surgery.

Material and methods

65 THA were performed in 59 patients (34 men, 25 women, mean age 73 years, 55–79). Mean latest follow-up was 8,3 years (4–14). Indications were 42 primary THA (osteoarthrosis) and 21 revisions (11 recurrent dislocation, 6 acetabular PE wear, 4 femoral loosening). Surgical approach was always antero-lateral. All patients were implanted with the same dual mobility cementless cup. The same cementless corail-type stem was used for primary THA cases. All the cemenless implants were hydroxyapatite coated. The disability caused by the disease was classified according to Hoehn and Yahr. (19 stage 1, 21 stage 2,16 stage 3)


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 50 - 50
1 Apr 2018
Kim Y Kim Y Hwang K Moon J
Full Access

Purpose

The posterolateral or posterior approach for total hip arthroplasty has the advantages of preserving the hip abductor musculature and providing good visualization during femoral preparation and component insertion. Although posterolateral approach is one of the popular approaches in hip arthroplasty, it has been reported high dislocation rate as a drawback. To compensate the drawback the repair of short external rotator of hip is thought to be important. Therefore, we investigated incidence of failed repaired short external rotator muscles, dislocation rate and time of failure between tendon to tendon and tendon to bone repair technique through prospective study more than 1 year follow up.

Materials and methods

We performed 213 hip arthroplasties in 202 patients from May 2012 to January 2015. After exclusion of 15 hips due to follow-up loss(9 hips), death(2 hips), greater trochanteric fragment displacement(3 hips) and severe contracted short external rotator(1 hip), we investigated 198 hips in 187 patients. 57 patients were male and 130 patients were female. The mean age of patient was 70.4 (32–98) years. Reattachment short external rotator with posterior capsule to postero-superior aspect of greater trochanter(tendon to bone group, 111 hips) or to the tendon(tendon to tendon group, 87 hips) was performed. Two No.26 metal wire markers were fixed at the greater trochanter tip and short external rotator tendon respectively with a distance less than 1.2cm, and the distance between two wire markers was observed at postoperative 1 day, 2 weeks, 3 months, and annually radiographs in neutral position. When the distance was more than 2.5cm or one of the wire markers was invisible, we defined them the failure of short external rotator repair. The mean follow up period was 28.8 (12–45) months.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 33 - 33
1 Apr 2018
Song M Kim Y Yoo S Kang S Kwack C
Full Access

Purpose

Unicompartmental Knee Arthroplasty (UKA) has been indicated for inactive elderly patients over 60, but for young and active patients less than 60 years old, it has been regarded as a contraindication. The purpose of this study is to evaluate the usefulness of UKA performed on young Asian patients under 60 years of age by analyzing clinical outcomes, complications and survival rate.

Materials and Methods

The subjects were 82 cases, which were followed up for at least 5 years (from 5 to 12 years). Only Oxford phase III® (Biomet Orthopedics, Inc, Warsaw, USA) prosthesis was used for all cases. The clinical evaluation was done by the range of motion, Knee society score (KSS), WOMAC score. The radiographic evaluation was performed on weight bearing long-leg radiographs, AP and lateral view of the knee and skyline view of the patella. The survival rate was estimated by Kaplan-Meier survival analysis.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 79 - 79
1 Jan 2018
Maranho D Davila A Novais E Kim Y Millis M
Full Access

Slipped capital femoral epiphysis (SCFE) is associated with a spectrum of proximal femoral deformity and femoroacetabular impingement (FAI). Little attention has been given, however, to the possible effect of SCFE on remaining hip growth. Our observation that some acetabula in hips with SCFE have various dysmorphology led us to evaluate the growth of the hip in our patients with SCFE. We performed an IRB-approved retrospective study of our intramural SCFE database which identified 108 hips with unilateral SCFE, at least 2 years of radiographic followup, and closure of triradiate cartilage, greater trochanter and proximal femoral physis. The contralateral non-SCFE hip was used as control. Average age at presentation was 12.3 y. 49 patients were male, 59 female.

Statistically significant differences were noted between SCFE and control hip both at both presentation and last followup(FU): Mean LCEA lower in SCFE hip at presentation by 0.97 degree; increasing to 4.36 degrees at last FU(p<0.0001). No difference noted in mean Tonnis roof angle at presentation, but at last FU SCFE hips had mean roof angle difference of 3.2 degrees higher than control(p<.0001).

In some of our SCFE patients, acetabular deformity has impacted treatment. Ongoing studies may clarify risk factors for the development of problematic acetabular deformity associated with SCFE and perhaps allow prevention of secondary acetabular deformity.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 78 - 78
1 Jan 2018
Maranho D Kiapour A Kim Y Novais E
Full Access

The intra-epiphyseal growth of the proximal femur has been focus of studies because of the potential relationship with the development of slipped capital femoral epiphysis and cam deformity in femoroacetabular impingement. We aimed to evaluate the developmental pattern of the epiphyseal tubercle and extension in normal boys and girls from eight to fifteen years, without hip conditions. We performed three-dimensional (3D) analysis of pelvic computed tomographic scans of 80 subjects with suspect of appendicitis, consisting of five boys and five girls for each age, from eight to 15 years old. Images were segmented slice by slice at the level of the growth plate using biplanar orientation. The 3D-segmented epiphyses were used to measure the location and height of the tubercle, the height of the epiphyseal extension, and the epiphyseal diameter. We found that the epiphyseal tubercle was eccentrically located at the posterolateral quadrant of the physeal surface. The absolute height of the epiphyseal tubercle did not vary between ages (R2=0.04; p=0.101). The epiphyseal diameter increased with age (R2=0.74; p<0.001), making the tubercle height proportionally smaller with the epiphyseal growth (9% reduction in tubercle height normalised by the epiphyseal diameter). The normalised epiphyseal extension height significantly increased by 160% from 8 to 15 years of age. Our observation validates the hypothesis of the cupping mechanism provided by the peripheral growth of the epiphyseal extension, while the epiphyseal tubercle relatively decreases in size during the skeletal growth. Further research will be important to determine the role of these structures in the epiphyseal stability.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 18 - 18
1 Mar 2017
Pun S Merz M Bowen G Hingsammer A Yen Y Kim Y Millis M
Full Access

Purpose

Periacetabular osteotomy (PAO) is a versatile acetabular reorienting procedure that is most commonly used to provide greater femoral head coverage in adolescent hip dysplasia. However, PAO can also be used to reorient the acetabulum in the opposite direction to treat femoroacetabular impingement (FAI) due to acetabular over-coverage. We describe the indications, surgical technique, and early results of reverse PAO to reduce femoral head coverage in symptomatic hips with FAI due to acetabular over-coverage.

Methods

IRB approval was obtained to retrospectively review cases of symptomatic acetabular over-coverage treated with reverse PAO and that had a minimum of two years follow-up. All hips had atypical intraoperative positioning of the acetabular fragment to uncover the lateral and anterior aspects of the femoral head, with or without anteverting the acetabulum. Prospectively collected pre- and post-operative demographics, WOMAC scores, Modified Harris Hip Score (MHHS), and radiographic measurements consisting of the lateral center edge angle (LCEA), Tönnis angle (TA), and anterior center edge angle (ACEA) were compared using student's t-test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 35 - 35
1 Feb 2017
Jo W Lee Y Ha Y Koo K Lim Y Kwon S Kim Y
Full Access

Background

Although thigh pain is an annoying problem after total hip arthroplasty (THA), little information has been known about its natural course.

Methods

To determine the frequency, time of onset, and duration of thigh pain after cementless THA, we evaluated 240 patients (240 hips) who underwent primary THA because of femoral head osteonecrosis with the use of a single tapered stem.


Bone & Joint Research
Vol. 5, Issue 11 | Pages 544 - 551
1 Nov 2016
Kim Y Bok DH Chang H Kim SW Park MS Oh JK Kim J Kim T

Objectives

Although vertebroplasty is very effective for relieving acute pain from an osteoporotic vertebral compression fracture, not all patients who undergo vertebroplasty receive the same degree of benefit from the procedure. In order to identify the ideal candidate for vertebroplasty, pre-operative prognostic demographic or clinico-radiological factors need to be identified. The objective of this study was to identify the pre-operative prognostic factors related to the effect of vertebroplasty on acute pain control using a cohort of surgically and non-surgically managed patients.

Patients and Methods

Patients with single-level acute osteoporotic vertebral compression fracture at thoracolumbar junction (T10 to L2) were followed. If the patients were not satisfied with acute pain reduction after a three-week conservative treatment, vertebroplasty was recommended. Pain assessment was carried out at the time of diagnosis, as well as three, four, six, and 12 weeks after the diagnosis. The effect of vertebroplasty, compared with conservative treatment, on back pain (visual analogue score, VAS) was analysed with the use of analysis-of-covariance models that adjusted for pre-operative VAS scores.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 100 - 100
1 May 2016
Kim S Lim Y Kwon S Sun D Kim Y Ju S
Full Access

Introduction

The acetabular cup should be properly oriented to prevent dislocation and to reduce wear and leg length discrepancy. Despite advances in surgical techniques and instrumentation, achieving proper cup placement in total hip arthroplasty (THA) is challenging with potentially large variations of cup position and limited accuracy. We evaluated whether cup placement on anatomical location ensured original center of rotation (COR) and surgeon's experiences of THA reduced variations in acetabular component positioning.

Methods

We retrospectively reviewed 145 patients (145 hips) of unilateral THAs with normal contralateral structures of acetabulum and femoral head. All surgeries were performed using the modified posterolateral approach that preserves short external rotator muscles. All of the 145 THAs were performed by two surgeons, who were in the same teaching hospital, but had differences in surgical experience and expertise for THA. The patients were divided into two groups based upon surgical experience: (1) the highly experienced surgeon's group: who had previously performed over 1000 THAs (YSK, 101 hips), and (2) the less experienced novice's group: who had performed fewer than 30 THAs (YWL, 44 hips). Real vertical distances, from the COR to the inter-tear drop line, and the real horizontal distances, from the COR to the lateral wall of the tear drop, were measured preoperatively using picture archiving communication system (PACS) based precise method. Postoperative ones were measured and equalized by use of a magnification marker placed on preoperative plain radiographs. And cup inclination was measured directly on the AP radiographs and anteversion was calculated by trigonometric functions. The patient's mean age was 52.1 years (range, 20–86).


The Bone & Joint Journal
Vol. 98-B, Issue 5 | Pages 703 - 709
1 May 2016
Kim Y Kang HG Kim JH Kim S Lin PP Kim HS

Aims

The purpose of the study was to investigate whether closed intramedullary (IM) nailing with percutaneous cement augmentation is better than conventional closed nailing at relieving pain and suppressing tumours in patients with metastases of the femur and humerus.

Patients and Methods

A total of 43 patients (27 men, 16 women, mean age 63.7 years, standard deviation (sd) 12.2; 21 to 84) underwent closed IM nailing with cement augmentation for long bone metastases. A further 27 patients, who underwent conventional closed IM nailing, served as controls. Pain was assessed using a visual analogue scale (VAS) score pre-operatively (pre-operative VAS), one week post-operatively (immediate post-operative VAS), and at six weeks post-operatively (follow-up post-operative VAS). Progression of the tumour was evaluated in subgroups of patients using F-18-fludeoxyglucose (F-18-FDG) positron emission tomography (PET)/computed tomography (CT) and/or bone scintigraphy (BS), at a mean of 8.8 and 7.2 months post-operatively, respectively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 25 - 25
1 May 2016
Seo J Yoo O In Y Kang B Sun D Kim Y
Full Access

Introduction

Knee joint should be aligned for reconstruction of the function in Total Knee Replacement(TKR). Although a surgeon try to correct the alignment of a knee joint, sometimes varus/valgus alignment has been tried in order to reconstruct function of knee joint. As a result, the varus or valgus alignment affects to ligaments and soft tissue, and the contact condition is changed between femoral component and tibial insert. One of important factor, wear characteristics of an implant can be changed due to the contact condition. In this study, we performed static contact tests from extension to flexion in varus and valgus to define the effect to contact condition when the alignment is varus or valgus.

Methods

LOSPA TKR femoral component #6 and Tibial insert #5 manufactured by Corentec Co., Ltd. were used as test specimens. The tests have performed with adapting ASTM F2777–10 ‘Standard Test Method for Evaluating Knee Bearing (Tibial Insert) Endurance and Deformation under High Flexion’. The test set like as Fig. 1. The load is applied at 7:3 ratio of lateral-medial by adapting gait analysis. The 5° of jig is used to compare the result in neutral, varus and valgus. The fuji films were used in tests were scanned, and the results were analyzed the compressed area and contact stress as angles of flexion in neutral stance and varus/valgus from scanning. The tests were performed 5 times per each for a reliability.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 99 - 99
1 May 2016
Kim J Yoo O Seo J Jang Y Kim J Sun D Kim Y
Full Access

Introduction

A stem extension improves fixation stability of a tibial component. We need caution not to contact the tibial cortex with an offset adaptor. A symmetric tibial stem design often requires the component's re-positioning with negative effects. Therefore, the objective of this study was to validate clinical efficacy of a tibial baseplate with asymmetric stemmed position (TB-ASP) using aligning outlier rate. We hypothesized that TB-ASP design will be better aligned without unessential offset adaptor than a tibial baseplate with symmetric stemmed position (TB-SSP).

Methods

TB-ASP was designed based on the anthropometric standard model (58 female cadavers, 54.7±11.4 years)(Figure 1.). To validate the stem position, 3D bone models of 20 OA patients (71.8±7.2 years) was reconstructed. All virtual surgery has done by one surgeon with consistent surgical procedure for the analysis criteria.

An analysis of TB-ASP's aligning outlier was proceeded by following steps; 1) aligning tibial baseplate to the line from medial 1/3 tuberosity to the center of PCL, 2) selecting tibial baseplate's size for maximal bone coverage without problematic overhang, 3) trying to displace tibial baseplate and stem extension(120mm long) not to contact tibial cortex. A case invading tibial cortex was considered to be an outlier. The ratio using offset adaptor was compared to those of TB-SSP. Statistical analysis was performed using paired t-test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 2 - 2
1 May 2016
Lim Y Kwon S Sun D Kim S Kim J Choi S Kim Y
Full Access

Introduction

3-D Printing with direct metal tooling (DMT) technology was innovatively introduced in the field of surface treatment of prosthesis to improve, moreover to overcome the problems of plasma spray, hopefully resulting in opening the possibility of another page of coating technology. We presumed such modification on the surface of Co-Cr alloy by DMT would improve the ability of Co-Cr alloys to osseointegrate.

Method

We compared the in vitro and in vivo ability of cells to adhere to DMT coated Co-Cr alloy to that of two different types of surface modifications: machined and plasma spray(TPS). We performed energy-dispersive x-ray spectroscopy and scanned electron microscopy investigations to assess the structure and morphology of the surfaces. Biologic and morphologic responses to osteoblast cell lines of human were then examined by measuring cell proliferation, cell differentiation (alkaline phosphatase activity), and avb3 integrin. The cell proliferation rate, alkaline phosphatase activity, and cell adhesion in the MAO group increased in comparison to those in the machined and grit-blasted groups.


Between 1993 and 2003, 67 consecutive revision total hip arthroplasties were performed in 65 patients, including 52 women and 13 men, using hydroxyapatite (HA) granules supported by a Kerboull-type reinforcement acetabular device. The average age at the time of index surgery was 68.6 years. The Acetabular bone loss according to the American Academy of Orthopaedic Surgeons (AAOS) system was type II for 7 hips, type III for 58 hips, and type IV for one hip. The Kerboull-type acetabular reinforcement device used was Kerboull Cross Plate in 18 hips and KT Plate in 49 hips. HA granules of sizes 0.9 to1.2 mm (G4) and 3.0–5.0 mm (G6) were mixed in a ratio of 1:1. Autografts were used to reconstruct the major segmental defects in 7 hips. At the time of this study 30 hips were lost of follow-up. Among 30 hips 22 hips were lost of follow-up because of the death of the patients. The remaining 37 hips were examined clinically and radiologically. The mean follow-up period of the series was 12.8 years. Complications were examined and clinical evaluation was done using Japanese Orthopaedic Association (JOA) hip score. The criterion for loosening of the acetabular component was cup migration exceeding 3 mm or angular rotation exceeding 3 degrees or breakage of the device. Among the entire series of 67 hips postoperative complications included dislocation in 3 hips, infection in 2 hips and revision in 4 hips. Two hips were revised for loosening and the other two hips were revised for infection. The JOA hip score increased from a mean value of 48.0 preoperatively to 76.8 at the last follow-up. Radiologically 5 hips were loose. Two hips among them were revised. Survival rate of the acetabular component at 10 years was 97.1% using acetabular revision for loosening as the end point and 90.6% using radiological loosening as the end point. Acetabular reconstruction with HA granules and a Kerboull-type acetabular device provided satisfactory clinical and radiographic results at 12.8 post-operative years.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 135 - 135
1 Jan 2016
Kwon S Kim Y Lim YW Jo WL
Full Access

The plasma spray(TPS) has come to be accepted as one of the more reliable methods of porous coating of prosthesis, it is not without some technical limitations, especially with regard to precise modulation of pore size, porosity, and roughness. However, the plasma spray(TPS) not often but seriously faces problems such as bead detachment related poor osteointegration, weakness of metal strength and high manufacturing costs in addition to its various technical limitations. Currently, there has been much research into developing a more economical and effective method for porous coating of the prosthesis.

In light of such demand, 3D Printing with DMT Technology has been introduced into the field of surface treatment of prosthesis with promising expectations. DMT technology -an additive fabrication process that uses high-power laser and various metal powders in order to produce fully dense and geometrically complex metal components, molds, and dies directly from digital CAD model data of 3D subjects aims to help overcome many of the problems associated with plasma spray and thereby open a new chapter of endless possibilities for coating technology.

In this study, the porous coating specimen using 3-D DMT metal printing was characterized morphologically as well as biomechanically, in terms of 1) pore size 2) porosity 3) tensile strength 4) shear strength 5) roughness respectively. The biological cyto-compatibility was evaluated by culturing human osteoblast-like cells(Saos-2: ATCC HTB85) on the surface of round discs with porous coating to demonstrate the biological influence on the porosity of the specimens with different surface treatment for comparative analysis. The evaluation was accompanied by assessment of cell proliferation and morphology with arrangement of actin filament and expression of adhesion molecule with αvβ3 integrin.

While 3-D DMT coating specimen showed relatively regular porosity in the range of 150–500µm with the increase of porosity about 83%, the mechanical behavior remarkably improved, compared to TPS: shear strength 13%, fatigue failure 30%, roughness 16%, respectively. Also worth noting, the tensile strength was unable to be measured because the glue for test had fallen off. (Fig. 1) There is no transitional zone underneath the porous coating layer.(Fig. 2) From the aspect of biocompatibility, 3-D coating showed better cell attachment, spreading of cytoskeleton, cell proliferation, and expression of osteogenic markers than TPS, even if not significantly.(Fig. 3) Additionally, cell migration assay was performed with double chamber study, and gene expression was evaluated by measuring alkaline phosphatase(ALP) levels and analyzing mRNA expression for ostepontin(OPG) and osteocalcin(OC).

In conclusion, the study reinforces the popular stance that the implementation of 3-D DMT could open up new possibilities for coating technology and form a new chapter in the history of prosthesis development.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 103 - 103
1 Jan 2016
Kim Y Tanaka C Maki A Tada H Kanoe H Shirai T
Full Access

Periprosthetic femoral fractures are becoming increasingly common and are a major complication of total hip arthroplasty (THA) and bipolar hemiarthroplasty (BHA). We report a retrospective review of the outcomes of treatment of 11 periprosthetic fractures after femoral revision using a long stem. Eleven female patients with a mean age of 79.2 years (70 to 91 years) were treated for a Vancouver type B1 fracture between 1998 and 2013. The status of the initial arthroplasty was THA in 5 patients and BHA in 6 patients. The original diagnosis was femoral neck fracture in 5 patients, osteoarthritis in 5 patients, and avascular necrosis of femoral head in 1 patient. Seven patients had had a cemented femoral component and 4 had had a cementless femoral component. The mean numbers of previous surgeries were 3.2 times (2 to 5 times). A previous history of fracture in the same femur was found in 7 hips including 5 femoral neck fractures, 3 periprosthetic fractures. The cause of the latest revision surgery was aseptic loosening in 6 hips, periprosthetic fracture in 3 hips, and infection in 2 hips. The average time to fracture after femoral revision using a long stem was 106.5 months (12 to 240 months). The average follow-up was 58.9 months (8 to 180 months). The fracture pattern was a transverse fracture in 6 hips and an oblique fracture in 5 hips. The type B1 fractures were treated with open reduction and internal fixation in 9 hips, 6 of which were reinforced with bone grafts. Seven patients were treated with a locking compression plate and cerclage wiring, and 2 patients were treated with a Dall-Miles system. Two other periprosthetic fractures were treated with femoral revision. One was revised because of stem breakage, and the other was a transverse fracture associated with very poor bone quality, which received a femoral revision with a long stem and a locking compression plate. All fractures except one achieved primary union. This failed case had a bone defect at the fracture site, and revision surgery using a cementless long stem and allografts was successful. These finding suggest that a type B1 fracture after revision using a long stem associated with very poor bone quality or bone loss might be considered as a type B3 fracture, and femoral revision might be the treatment of choice.


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1197 - 1203
1 Sep 2015
Kim Y Park J Kim J

A number of studies have reported satisfactory results from the isolated revision of an acetabular component. However, many of these studies reported only the short- to intermediate-term results of heterogeneous bearing surfaces in a mixed age group.

We present our experience of using a ceramic-on-ceramic (CoC) bearing for isolated revision of an uncemented acetabular component in 166 patients (187 hips) who were under the age of 50 years at the time of revision. There were 78 men and 88 women with a mean age of 47.4 years (28 to 49). The most common reason for revision was polyethylene wear and acetabular osteolysis in 123 hips (66%), followed by aseptic loosening in 49 hips (26%).

We report the clinical and radiological outcome, complication rate, and survivorship of this group. The mean duration of follow-up was 15.6 years (11 to 19).

The mean pre-operative Harris hip score was 33 points (1 to 58), and improved to a mean of 88 points (51 to 100) at follow-up. The mean pre-operative total Western Ontario and McMaster Universities Osteoarthritis Index score was 63.2 (43 to 91) and improved to 19.8 points (9 to 61) post-operatively. Overall, 153 of 166 patients (92%) were satisfied with their outcome. Kaplan–Meier survivorship analysis, with revision or radiological evidence of implant failure (13 patients, 8%) as end-points, was 92% at 15 years (95% confidence interval 0.89 to 0.97).

Isolated revision of a cementless acetabular component using a CoC bearing gives good results in patients under 50 years of age.

Cite this article: Bone Joint J 2015;97-B:1197–1203.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 141 - 141
1 Mar 2013
Chang YJ Kim Y Lim YW Song J Kwon SY
Full Access

Introduction

To minimize leg length discrepancies (LLD), preoperative measures are taken using the PACS; the head center to the proximal end of the lesser trochanter distance (HLD) of the opposite side of the operating limb are calculated, while during operation, the modular neck selection is adapted to equal the opposing limb's length.

The purpose of this study was to see whether the HLD method would show far less occurrences of LLD, in comparison to the conventional method(preoperative templating and shuck test).

Method

349 (412 hips) patients who had undergone THRA were divided into two groups based upon which methods they had used to equalize limb length during operation: (1) HLD method, and (2) conventional methods. Six months after surgery, using the PACS system, LLD's of the two groups were compared.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 96 - 96
1 Mar 2013
Kim Y
Full Access

Introduction

47 yrs male patient had a prior history

2005 Fx. proximal tibia (open Fx.)

2007 Metal removal

2008 Arthroscopic debridement (2 times)

He visited out hospital with severe pain and tenderness X-ray (Fig 1) and MRI (Fig 2) findings as follows.

Conclusively, He had a chorinic osteomylitis of proximal tibia with soft tissue absess.

1st Surgery

I did arthroscopic debridement Arthroscopic finding shows synovitis, meniscus tear and chondromalacia. I did meticulous debridement (irrigation & curettage)

2nd Surgery

He did primary total knee arthro-plasty instead of two-stage exchange arthroplasty in may, 2010 at the another hospital

3rd Surgery

After 7 months since he had did total knee arthroplasty, he visited to my hospital again with sudden onset of painful swelling & heating sensation

4th Surgery

I did second stage reimplantation for infected total Knee arthroplasty after 7 weeks. Now he got a pain relief & ROM restroration.

Results

Follow up 12 months X-ray showing all implants to be well-positioned and stable. Clinically, there was no implant considered to be loose

In this study, the knee society and functional scores at final follow up were 82 and 68.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 241 - 241
1 Mar 2013
Lim YW Kwon SY Kim JY Kim Y
Full Access

Purpose

Ion implantation with a high kinetic energy has advantages in controlling the size and distribution of coating materials, helping to overcome the limitations of conventional methods. This method resulted in uniformly and homogeneously distributed in a CoCr alloy even without a further annealing process. The study was to investigate the wear rate of UHMWPE on CoCr alloy for metal head by plasma immersion ion implantation (PIII) treatments.

MATERIALS AND METHODS

Commercially CoCr alloy (ISO 5832-12, ASTM F1537, alloy 1) were used as the substrate. PIII surface treatments were performed in a high-vacuum chamber with a radio frequency plasma source. We divided with two groups: PIII CoCr alloy, CoCr ally as control. Wear amount of UHMWPE (ISO 5834-2, ASTM F648, Type 1) on CoCr alloy specimens (three samples per group) was evaluated after 500,000 and 1,000,000 cycles using pin-on disk wear tester. After test, surface morthology was examined by SEM, and surface roughness was calculated in both groups.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 242 - 242
1 Mar 2013
Lim YW Kim Y Kwon SY Chang YJ Kim KS
Full Access

Introduction

Inspired by mussel-adhesion phenomena in nature can integrate inorganic hydroxyapatite crystals within versatile materials. This is a simple, aqueous, two-step functionalization approach, called polydopamine-assisted hydroxyapatite formation (pHAF), that consists of i) the chemical activation of material surfaces via polydopamine coating and ii) the growth of hydroxyapatite in a simulated body fluid (SBF). We presumed polydopamine coating on the surface of titanium alloy would improve the ability of cementless stems to osseointegrate. We therefore compared the in vitro ability of cells to adhere to polydopamine coated Ti alloy and machined Ti alloy.

Method

We performed energy-dispersive x-ray spectroscopy and scanned electron microscopy investigations to assess the structure and morphology of the surfaces. Biologic and morphologic responses to osteoblast cell lines (MC3T-E1) were then examined by measuring cell proliferation, cell differentiation (alkaline phosphatase activity), and avb3 integrin.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 438 - 438
1 Sep 2012
Kim Y Kim J Joo J Park J
Full Access

Background

No study compared the clinical results of the posterior-stabilized mobile-bearing knee with those of nonposterior-stabilized mobile-bearing knee in the same patients. The purpose of this study was to examine whether the clinical and radiographic results, range of motion, patients satisfaction, and complication rates would be better in the knees with a posterior-stabilized mobile-bearing knee than in the knees with a nonposterior-stabilized mobile-bearing knee.

Methods

One hundred and fourteen patients (mean age, 67.9 years) received a nonposterior-stabilized mobile-bearing knee prosthesis in one knee and a posterior-stabilized mobile-bearing knee prosthesis in the contralateral knee. Seven patients were men, and 107 were women. At the time of each follow-up (mean, 7.3 years; range, seven to 7.6 years), the patients were assessed clinically and radiographically.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 174 - 174
1 Sep 2012
Shore BJ Kim Y Millis MB
Full Access

Purpose

Surgical dislocation is useful for assessing and treating proximal femoral hip deformities. Legg-Calv Perthes disease (LCPD) causes proximal femoral growth deformity, resulting in reduced femoral head-neck offset and femoracetabular incongruity. The purpose of this study was to demonstrate the efficacy and report the short-term results of surgical hip dislocation for the treatment of adolescents with healed LCPD.

Method

This retrospective review included 29 adolescents [19 males and 10 females, age 17 (range nine-35)] with LCPD, who underwent surgical hip dislocation between January 2001 and December 2009. All subjects had a clear diagnosis of LCPD, pre and postoperative WOMAC scores and at least one year of clinical and radiographic follow up. In addition to surgical dislocation, all patients underwent femoral head-neck osteoplasty, 21 underwent relative femoral neck lengthening and trochanteric transfer, 12 underwent intertrochanteric osteotomy and seven had labral debridement. The average follow-up was three years from the time of surgical intervention.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 9 | Pages 1221 - 1227
1 Sep 2012
Kim Y Park J Kim J

Despite many claims of good wear properties following total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral component, there are conflicting clinical results. We hypothesised that there would be no difference in either the mid-term clinical and radiological outcomes or the characteristics of the polyethylene wear particles (weight, size and shape) in patients using an OxZr or cobalt-chrome (CoCr) femoral component. In all 331 patients underwent bilateral TKR, receiving an OxZr femoral component in one knee and a CoCr femoral component in the other. The mean follow-up was 7.5 years (6 to 8). Following aspiration, polyethylene wear particles were analysed using thermogravimetric methods and scanning electron microscopy. At the most recent follow-up, the mean Knee Society score, Western Ontario and McMaster Universities Osteoarthritis Index score, range of movement and satisfaction score were not significantly different in the two groups. The mean weight, size, aspect ratio and roundness of the aspirated wear particles were similar for each femoral component. Survivorship of the femoral, tibial and patellar components was 100% in both groups.

In the absence of evidence of an advantage in the medium term we cannot justify the additional expense of an OxZr femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 774 - 781
1 Jun 2012
Kim Y Oh J

We compared the clinical and radiological outcomes of two cementless femoral stems in the treatment of patients with a Garden III or IV fracture of the femoral neck. A total of 70 patients (70 hips) in each group were enrolled into a prospective randomised study. One group received a short anatomical cementless stem and the other received a conventional cementless stem. Their mean age was 74.9 years (50 to 94) and 76.0 years (55 to 96), respectively (p = 0.328). The mean follow-up was 4.1 years (2 to 5) and 4.8 years (2 to 6), respectively. Perfusion lung scans and high resolution chest CTs were performed to detect pulmonary microemboli.

At final follow-up there were no statistically significant differences between the short anatomical and the conventional stems with regard to the mean Harris hip score (85.7 (66 to 100) versus 86.5 (55 to 100); p = 0.791), the mean Western Ontario and McMaster Universities Osteoarthritis Index (17 (6 to 34) versus 16 (5 to 35); p = 0.13) or the mean University of California, Los Angeles activity score (5 (3 to 6) versus 4 (3 to 6); p = 0.032). No patient with a short stem had thigh pain, but 11 patients (16%) with a conventional stem had thigh pain. No patients with a short stem had symptomatic pulmonary microemboli, but 11 patients with a conventional stem had pulmonary microemboli (symptomatic in three patients and asymptomatic in eight patients). One hip (1.4%) in the short stem group and eight (11.4%) in the conventional group had an intra-operative undisplaced fracture of the calcar. No component was revised for aseptic loosening in either group. One acetabular component in the short stem group and two acetabular components in the conventional stem group were revised for recurrent dislocation.

Our study demonstrated that despite the poor bone quality in these elderly patients with a fracture of the femoral neck, osseo-integration was obtained in all hips in both groups. However, the incidence of thigh pain, pulmonary microemboli and peri-prosthetic fracture was significantly higher in the conventional stem group than in the short stem group.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_VIII | Pages 21 - 21
1 Mar 2012
Kim Y
Full Access

Introduction

What is the most effective treatment of the early stages for osteonecrosis of the femoral head? Since the results of several treatment modalities such as multiple drilling, core decompression with or without bone graft, and vascularized fibular grafts have not been completely successful, we tried multiple drilling and stem cell transplantation to treat the early stages of osteonecrosis of the femoral head and to minimize patient morbidity. We report the clinical and radiological results of stem cell transplantation and core decompression.

Methods

One hundred and twenty-eight patients (190 hips) who had undergone surgery were divided in two groups based upon which treatment they had received: (1) multiple drilling and stem cell transplantation, and (2) core decompression, curettage, and bone graft. The clinical and radiological results of the two groups were compared. We defined failure as the need for additional surgery, or a Harris hip score of less than 75 points.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 190 - 193
1 Feb 2012
Koh Y Moon H Kim Y Park Y Jo S Kwon S

We compared extrusion of the allograft after medial and lateral meniscal allograft transplantation and examined the correlation between the extent of extrusion and the clinical outcome. A total of 73 lateral and 26 medial meniscus allografts were evaluated by MRI at a mean of 32 months (24 to 59) in 99 patients (67 men, 32 women) with a mean age of 35 years (21 to 52). The absolute values and the proportional widths of extruded menisci as a percentage were measured in coronal images that showed maximum extrusion. Functional assessments were performed using Lysholm scores. The mean extrusion was 4.7 mm (1.8 to 7.7) for lateral menisci and 2.9 mm (1.2 to 6.5) for medial menisci (p < 0.001), and the mean percentage extrusions were 52.0% (23.8% to 81.8%) and 31.2% (11.6% to 63.4%), respectively (p < 0.001). Mean Lysholm scores increased significantly from 49.0 (10 to 83) pre-operatively to 86.6 (33 to 99) at final follow-up for lateral menisci (p = 0.001) and from 50.9 (15 to 88) to 88.3 (32 to 100) for medial menisci (p < 0.001). The final mean Lysholm scores were similar in the two groups (p = 0.312). Furthermore, Lysholm scores were not found to be correlated with degree of extrusion (p = 0.242).

Thus, transplanted lateral menisci extrude more significantly than transplanted medial menisci. However, the clinical outcome after meniscal transplantation was not found to be adversely affected by extrusion of the allograft.


It has been suggested that the wear of ultra-high molecular weight polyethylene (UHMWPE) in total hip replacement is substantially reduced when the femoral head is ceramic rather than metal. However, studies of alumina and zirconia ceramic femoral heads on the penetration of an UHMWPE liner in vivo have given conflicting results.

The purpose of this study was to examine the surface characteristics of 30 alumina and 24 zirconia ceramic femoral heads and to identify any phase transformation in the zirconia heads. We also studied the penetration rate of alumina and zirconia heads into contemporary UHMWPE liners. The alumina heads had been implanted for a mean of 11.3 years (8.1 to 16.2) and zirconia heads for a mean of 9.8 years (7.5 to 15).

The mean surface roughness values of the explanted alumina heads (Ra 40.12 nm and Rpm 578.34 nm) were similar to those for the explanted zirconia heads (Ra 36.21 nm and Rpm 607.34 nm). The mean value of the monoclinic phase of two control zirconia heads was 1% (0.8% to 1.5%) and 1.2% (0.9% to 1.3%), respectively. The mean value of the monoclinic phase of 24 explanted zirconia heads was 7.3% (1% to 26%).

In the alumina group, the mean linear penetration rate of the UMWPE liner was 0.10 mm/yr (0.09 to 0.12) in hips with low Ra and Rpm values (13.22 nm and 85.91 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.13 mm/yr (0.07 to 0.23) in hips with high Ra and Rpm values (198.72 nm and 1329 nm, respectively). This difference was significant (p = 0.041).

In the zirconia head group, the mean linear penetration rate of the UHMWPE liner was 0.09 mm/yr (0.07 to 0.14) in hips with low Ra and Rpm values (12.78 nm and 92.99 nm, respectively). The mean linear penetration rate of the UHMWPE liner was 0.12 mm/yr (0.08 to 0.22) in hips with high Ra and Rpm values (199.21 nm and 1381 nm, respectively). This difference was significant (p = 0.039).

The explanted zirconia heads which had a minimal phase transformation had similar surface roughness and a similar penetration rate of UHMWPE liner as the explanted alumina head.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 412 - 412
1 Nov 2011
Kim Y Kim J Huh W Lee K
Full Access

Although total knee arthroplasty (TKA) has been a reliable procedure providing durable pain relief, polyethylene (PE) wear remains a major limitation of the long-term success of TKA. One potential method of lowering PE wear in TKA is to use oxidized zirconium (OxZr)-bearing surface. Although wear simulating testing of an OxZr counter surface of femoral component produced less PE wear and fewer particles than did cobalt-chrome (Co-Cr) counter surface of femoral component [1–4], this finding has not been demonstrated in vivo to our knowledge.

We measured in vivo PE wear by isolating and analyzing PE wear particles in synovial fluid from wellfunctioning TKA [5]. The purpose of the current study was to determine the size, shape, and amount of PE wear particles isolated from synovial fluid of patients who underwent a bilateral simultaneous TKA prosthesis, but different materials of femoral components.

We performed a bilateral simultaneous TKA in 100 patients (200 knees) who received an OxZr femoral component in one knee and a Co-Cr femoral component in the other. Mean age was 55.6 (44–60) years. Synovial fluid was obtained from 28 patients (56 knees) who had undergone a simultaneous bilateral TKA under completely sterile conditions at one or two years after the operation. Randomization to an OxZr or Co-Cr femoral component was accomplished with use of a sealed study number envelope, which was opened in the operating room before the skin incision had been made. After the opening the randomization envelope, the first knee received prosthesis indicated by the envelope (OxZr or Co-Cr component) and the contralateral (second TKA) knee received the other prosthesis (OxZr or Co-Cr component).

All operations were performed by one surgeon using the same design of total knee prosthesis: Genesis II (Smith and Nephew, Memphis, Tennessee). Only the material of the femoral component differed between two groups. The preoperative diagnosis was osteoarthritis in all patients. Preoperative and post operative KS and HSS knee scores, KS functional scores and UCLA activity scores were evaluated.

The amount of polyethylene wear particles in the aspirated synovial fluid sample was analyzed by thermogravimetic analysis (TGA) using a TGA instrument (TGA/SDTA 84le model, Mettler Toledo CO., Greifensee, Switzerland). The weight of the sample solution was measured before and after removing the organic content by heating the sample solution. The sample solution was casted onto petri dishes. The petri dish was covered and kept in a dry oven at 60°C for 2 days. While the sample solution was kept in a dry oven for 2 days, a small hole was made on the cover of the petri dish to allow water to evaporate slowly for 2 days. After this procedure, the cover of petri dish was removed and TGA sample was dried at 60°C for another 2 days. After the sample was completely dried out, the dried sample was measured using analytical balance.

TGA was used to determine the weight change profiles of polyethylene subject to heating under a nitrogen atmosphere. The nitrogen flow rate was kept constant at 50mL per minute. TGA data were taken at heating rate as 5°C per minute in the temperature range of 20° to 1000°C. The weight loss data were recorded as a function of time and temperature using special software in computer. When the temperature reached to the point of decomposition of the sample, the sample started to lose weight. By calculating the weight of the sample around the temperature which led to start to decomposition, real amount of polyethylene in the sample was measured. The size and shape of PE particles were examined using scanning electron microscopy (JSH-6360A model, Jeol Co., Tokyo, Japan). The samples were coated using a platinum sputtering machine for 20 sec.

ANOVA, nonparametric chi square test, nonpaired t-test and Mann-Whitney U-test were used for statistical analyses. Differences of P< 0.05 were considered statistically significant.

Mean preoperative KS (27.5 vs 27.2 points) scores, HSS (51.1 vs 51.2 points) knee scores, KS functional scores (55.4 vs 55.4 points) and UCLA activity scores (2.8 vs 2.8 point) were not significantly different between two groups. Mean postoperative KS (93 vs 92 points), HSS knee scores (90 vs 89 points), KS functional scores (78 vs 78 points), and UCLA activity scores (7.8 vs 7.8) were not significantly different. Mean weight of the polyethylene particles was 0.0219 g (SD, 0.0058) in the Co-Cr femoral component groups and it was 0.0214 g (SD, 0.005) in the OxZr group. This difference was not significant (P=0.711139, paired t-test). The size of particles was not different between the two groups. Also, shape of particles was not different between the two groups.

Under the condition and the duration of this study in this specific group of patients, TKA with OxZr or Co-CR femoral knee component had excellent clinical and radiographic outcomes with no osteolysis. While the wear simulator test in vitro demonstrated significant decrease in PE particles in the knees with an OxZr femoral component, our study in vivo revealed that total particle weight, size, and shape of PE wear particles were similar in the knees with an OxZr femoral component and in those with a Co-Cr femoral component.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 11 | Pages 1479 - 1486
1 Nov 2011
Park J Kim Y

The purpose of this prospective, randomised study was to evaluate the clinical and radiological results comparing the identical cemented or cementless NexGen total knee prostheses implanted bilaterally in the same patient. Sequential simultaneous bilateral total knee replacements were performed in 50 patients (100 knees). There were 39 women and 11 men with a mean age of 58.4 years (51 to 67) who received a cemented prosthesis in one knee and a cementless prosthesis in the other. The mean follow-up was 13.6 years (13 to 14). At final review, the mean Knee Society scores (96.2 (82 to 100) versus 97.7 (90 to 100)), the mean Western Ontario and McMaster Universities osteoarthritis index (34.5 (4 to 59) versus 35.6 (5 to 51)), the mean ranges of knee movement (124° (100° to 140°) versus 128° (110° to 140°)), mean patient satisfaction (8.1 (sd 1.9) versus 8.3 (sd 1.7)), and radiological results were similar in both groups. The rate of survival of the femoral components was 100% in both groups at 14 years. The rate of survival of the cemented tibial component was 100% and 98% in the cementless tibial component. No osteolysis was identified in either group. Our data have shown no advantage of cementless over cemented components in total knee replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 10 | Pages 1395 - 1399
1 Oct 2011
Lee D Kim NH Park J Hwang CJ Lee CS Kim Y Kang SJ Rhee JM

We performed a prospective study to examine the influence of the patient’s position on the location of the abdominal organs, to investigate the possibility of a true lateral approach for transforaminal endoscopic lumbar discectomy. Pre-operative abdominal CT scans were taken in 20 patients who underwent endoscopic lumbar discectomy. Axial images in parallel planes of each intervertebral disc from L1 to L5 were achieved in both supine and prone positions. The most horizontal approach angles possible to avoid injury to the abdominal organs were measured. The results demonstrated that the safe approach angles were significantly less (i.e., more horizontal) in the prone than in the supine position. Obstacles to a more lateral approach were mainly the liver, the spleen and the kidneys at L1/2 (39 of 40, 97.5%) and L2/3 (28 of 40, 70.0%), and the intestines at L3/4 (33 of 40, 82.5%) and L4/5 (30 of 30, 100%). A true lateral approach from each side was possible for 30 of the 40 discs at L3/4 (75%) and 23 of the 30 discs at L4/5 (76.7%). We concluded that a more horizontal approach for transforaminal endoscopic lumbar discectomy is possible in the prone position but not in the supine. Prone abdominal CT is more helpful in determining the trajectory of the endoscope. While a true lateral approach is feasible in many patients, our study shows it is not universally applicable.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 113 - 114
1 May 2011
Kim Y Choi Y Kim J
Full Access

Background: Although many of the contemporary fixed- and mobile bearing total knee systems have been using extensively world wide, there is limited information available regarding the incidence of osteolysis of the well functioning total knee arthroplasties. We performed this study to evaluate the clinical and radiographic outcomes, the incidence of osteolysis, the revision rates and implant survivorship of the fixed- and mobile-bearing total knee arthroplasties at ten to seventeen years follow-up.

Methods: We compared 488 patients (894 knees) who received a fixed-bearing total knee replacement and 445 patients (816 knees) who received a mobile-bearing total knee replacement. There were 187 men and 301 women (mean age, 58.6 years) in the fixed-bearing group and 167 men and 278 women (mean age, 55.7 years) in the mobile-bearing group. The mean follow-up was 12.6 years (range, ten to seventeen years) in the fixed-bearing group and 14.1 years (range, twelve to seventeen years) in the mobile-bearing group.

Results: The mean postoperative Knee Society knee and functional scores were 92.9 points and 83.5 points, respectively in the fixed-bearing group. The mean postoperative Knee Society knee and functional scores were 90.7 points and 83.8 points, respectively. Incidence of osteolysis was 1.6% (fourteen of 894 knees) in the fixed-bearing group and it was 2.2% (eighteen of 816 knees) in the mobile-bearing group at the final review. Revision rate was 3.7% (thirty-three of 894 knees) in the fixed-bearing group and it was 2.7% (twenty-two of 816 knees) in the mobile-bearing group. Kaplan-Meier survivorship of the fixed-bearing group was 96.3% (95% confidence interval, 0.87–1.0) at 13 years follow-up and it was 97% (95% confidence interval, 0.90–1.0) of the mobile-bearing group at 14 years follow-up.

Conclusions: The present study demonstrates that the clinical and radiographic outcomes, the incidence of osteolysis, the rate of revision and the implant survivorship were similar between the fixed-bearing and mobile-bearing total knee arthroplasties.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 587 - 592
1 May 2011
Kim Y Kim J Park J Joo J

We reviewed the results of 84 total hip replacements performed with a short metaphyseal-fitting anatomical cementless femoral component in 84 unselected consecutive patients with a mean age of 78.9 years (70 to 88). The mean follow-up was 4.6 years (4 to 5). The mean pre-operative Harris hip score was 26 points (0 to 56), which improved to 89 (61 to 100) at the final follow-up. No patient had thigh pain. The mean pre-operative Western Ontario and McMaster Universities osteoarthritis index score was 61 points (48 to 75), which improved to 21 (6 to 46). The mean University of California, Los Angeles activity score was 5.5 points (3 to 7) at the final follow-up. Osseointegration was seen in all femoral and acetabular components. All hips had grade 1 stress shielding of the proximal femur. No acetabular or femoral osteolysis was identified.

These results demonstrate that a short metaphyseal-fitting femoral component achieves optimal fixation without diaphyseal anchorage in elderly patients.


Background: Alumina ceramic-on-highly cross-linked polyethylene (Al-on-X-linked PE) is attractive because of the potential for reduced wear, osteolysis and loosening of the component. The purpose of this study was to evaluate the clinical and radiographic outcomes of cement-less total hip arthroplasties (THAs) using Al-on-X-linked PE bearing and to determine the rates of osteolysis using radiographs and computer tomographic (CT) scans in young patients with osteonecrosis of femoral head.

Methods: Consecutive primary cementless THAs using Al-on-X-linked PE bearing were performed in 71 patients (73 hips) who were younger than 50 years of age with osteonecrosis of the femoral head. There were 48 men (51 hips) and 23 women (23 hips). The average age at the time of the index arthroplasty was 45.5 years (range, 20 to 50 years). Osteolysis was evaluated using radiographs and CT scanning. The average follow-up was 10.5 years (range, 10 to 13 years).

Results: The mean preoperative Harris hip score was 50.6 points (range, 27 to 55 points), which was improved to 96 points (range, 85 to 100 points) at the final follow-up. Preoperative functional activity was improved significantly (p=0.001) at the latest follow-up. All acetabular and femoral components were fixed by bone ingrown. The mean polyethylene linear penetration was 0.05±0.02 mm per year (range, 0.02 mm to 0.08 mm per year). Radiographic and CT scans demonstrated that no acetabular or femoral osteolysis was detected in any hip at the latest follow-up.

Conclusions: The current generation of anatomic tapered cementless femoral component with Al-on-X-linked PE bearing is functioning well with no osteolysis at a 10-year minimum and average of 10.5-year follow-up in this series of young patients with osteonecrosis of the femoral head.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 4 | Pages 449 - 455
1 Apr 2011
Kim Y Kim J Park J Joo J

There have been comparatively few studies of the incidence of osteolysis and the survival of hybrid and cementless total hip replacements (THRs) in patients younger than 50 years of age. We prospectively reviewed 78 patients (109 hips) with a hybrid THR having a mean age of 43.4 years (21 to 50) and 79 patients (110 hips) with a cementless THR with a mean age of 46.8 years (21 to 49). The patients were evaluated clinically using the Harris hip score, the Western Ontario and McMaster Universities (WOMAC) osteoarthritis score and the University of California, Los Angeles (UCLA) activity score. Radiographs and CT scans were assessed for loosening and osteolysis. The mean follow-up was for 18.4 years (16 to 19) in both groups.

The mean post-operative Harris hip scores (91 points versus 90 points), the mean WOMAC scores (11 points versus 13 points) and UCLA activity scores (6.9 points versus 7.1 points) were similar in both groups. The revision rates of the acetabular component (13% versus 16%) and the femoral component (3% versus 4%), and the survival of the acetabular component (87% versus 84%) and the femoral component (97% versus 96%) were similar in both groups.

Although the long-term fixation of the acetabular metallic shell and the cemented and cementless femoral components was outstanding, wear and peri-acetabular osteolysis constitute the major challenges of THR in young patients.