ACETABULAR RECONSTRUCTION USING A KERBOULL-TYPE ACETABULAR REINFORCEMENT DEVICE AND HYDROXYAPATITE GRANULES FOR ACETABULAR LOOSENING: RESULTS AT AVERAGE 12.8 YEARS

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 4.



Abstract

Between 1993 and 2003, 67 consecutive revision total hip arthroplasties were performed in 65 patients, including 52 women and 13 men, using hydroxyapatite (HA) granules supported by a Kerboull-type reinforcement acetabular device. The average age at the time of index surgery was 68.6 years. The Acetabular bone loss according to the American Academy of Orthopaedic Surgeons (AAOS) system was type II for 7 hips, type III for 58 hips, and type IV for one hip. The Kerboull-type acetabular reinforcement device used was Kerboull Cross Plate in 18 hips and KT Plate in 49 hips. HA granules of sizes 0.9 to1.2 mm (G4) and 3.0–5.0 mm (G6) were mixed in a ratio of 1:1. Autografts were used to reconstruct the major segmental defects in 7 hips. At the time of this study 30 hips were lost of follow-up. Among 30 hips 22 hips were lost of follow-up because of the death of the patients. The remaining 37 hips were examined clinically and radiologically. The mean follow-up period of the series was 12.8 years. Complications were examined and clinical evaluation was done using Japanese Orthopaedic Association (JOA) hip score. The criterion for loosening of the acetabular component was cup migration exceeding 3 mm or angular rotation exceeding 3 degrees or breakage of the device. Among the entire series of 67 hips postoperative complications included dislocation in 3 hips, infection in 2 hips and revision in 4 hips. Two hips were revised for loosening and the other two hips were revised for infection. The JOA hip score increased from a mean value of 48.0 preoperatively to 76.8 at the last follow-up. Radiologically 5 hips were loose. Two hips among them were revised. Survival rate of the acetabular component at 10 years was 97.1% using acetabular revision for loosening as the end point and 90.6% using radiological loosening as the end point. Acetabular reconstruction with HA granules and a Kerboull-type acetabular device provided satisfactory clinical and radiographic results at 12.8 post-operative years.


Email: