header advert
Results 1 - 50 of 174
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1259 - 1264
1 Dec 2023
Hurley ET Hughes AJ Savage-Elliott I Dejour D Campbell KA Mulcahey MK Wittstein JR Jazrawi LM

Aims

The aim of this study was to establish consensus statements on the diagnosis, nonoperative management, and indications, if any, for medial patellofemoral complex (MPFC) repair in patients with patellar instability, using the modified Delphi approach.

Methods

A total of 60 surgeons from 11 countries were invited to develop consensus statements based on their expertise in this area. They were assigned to one of seven working groups defined by subtopics of interest within patellar instability. Consensus was defined as achieving between 80% and 89% agreement, strong consensus was defined as between 90% and 99% agreement, and 100% agreement was considered to be unanimous.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 873 - 880
17 Nov 2023
Swaby L Perry DC Walker K Hind D Mills A Jayasuriya R Totton N Desoysa L Chatters R Young B Sherratt F Latimer N Keetharuth A Kenison L Walters S Gardner A Ahuja S Campbell L Greenwood S Cole A

Aims

Scoliosis is a lateral curvature of the spine with associated rotation, often causing distress due to appearance. For some curves, there is good evidence to support the use of a spinal brace, worn for 20 to 24 hours a day to minimize the curve, making it as straight as possible during growth, preventing progression. Compliance can be poor due to appearance and comfort. A night-time brace, worn for eight to 12 hours, can achieve higher levels of curve correction while patients are supine, and could be preferable for patients, but evidence of efficacy is limited. This is the protocol for a randomized controlled trial of ‘full-time bracing’ versus ‘night-time bracing’ in adolescent idiopathic scoliosis (AIS).

Methods

UK paediatric spine clinics will recruit 780 participants aged ten to 15 years-old with AIS, Risser stage 0, 1, or 2, and curve size (Cobb angle) 20° to 40° with apex at or below T7. Patients are randomly allocated 1:1, to either full-time or night-time bracing. A qualitative sub-study will explore communication and experiences of families in terms of bracing and research. Patient and Public Involvement & Engagement informed study design and will assist with aspects of trial delivery and dissemination.


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims

Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA.

Methods

We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 30 - 30
1 Jun 2023
Tissingh E Goodier D Wright J Timms A Campbell M Crook G Calder P
Full Access

Introduction

The FitBone lengthening nail (Orthofix UK) is an intramedullary device licensed for the lengthening of long bones in adults in the UK. It contains a motor powered by electricity transmitted via an induction coil placed underneath the skin. It was developed in Germany two decades ago but uptake in the UK has only started more recently. The aim of this study was to review the first cohort of FitBone lengthening nails in a unit with significant experience of other lengthening nails (including PRECICE and Stryde).

Materials & Methods

Demographic, clinical and radiological data was prospectively collected on all FitBone cases starting in February 2022. Accuracy of lengthening rate, patient satisfaction and implant issues were all considered. Complications and learning points were recorded and discussed by the multidisciplinary team involved in the patients care.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 118 - 118
11 Apr 2023
Styczynska-Soczka K Cawley W Samuel K Campbell J Amin A Hall A
Full Access

Articular cartilage has poor repair potential and the tissue formed is mechanically incompetent. Mesenchymal stromal cells (MSCs) show chondrogenic properties and the ability to re-grow cartilage, however a viable human model for testing cartilage regeneration and repair is lacking. Here, we describe an ex vivo pre-clinical femoral head model for studying human cartilage repair using MSCs.

Human femoral heads (FHs) were obtained following femoral neck fracture with ethical permission/patient consent and full-depth cartilage wells made using a 3mm biopsy punch. Pancreas-derived mesenchymal stromal cells (P-MSC) were prepared in culture media at ~5000 cells/20µl and added to each well and leakage prevented with fibrin sealant. After 24hrs, the sealant was removed and medium replaced with StemProTM chondrogenesis differentiation medium. The FHs were incubated (37oC;5% CO2) for 3wks, followed by a further 3wks in standard medium with 10% human serum with regular medium changes throughout. Compared to wells with medium only, A-MSCs produced a thin film across the wells which was excised en-block, fixed with 4% paraformaldehyde and frozen for cryo-sectioning.

The cell/tissue films varied in thickness ranging over 20-440µm (82±21µm; mean±SEM; N=3 FHs). The thickness of MSC films abutting the cartilage wells was variable but generally greater (15-1880µm) than across the wells, suggesting an attachment to native articular cartilage. Staining of the films using safranin O (for glycosaminoglycans; quantified using ImageJ) was variable (3±8%; mean±SEM; N=3) but in one experiment reached 20% of the adjacent cartilage. A preliminary assessment of the repair tissue gave an O'Driscoll score of 10/24 (24 is best).

These preliminary results suggest the ex vivo femoral head model has promise for studying the capacity of MSCs to repair cartilage directly in human tissue, although optimising MSCs to produce hyaline-like tissue is essential.

Supported by the CSO (TCS/17/32).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 132 - 132
4 Apr 2023
Callary S Abrahams J Zeng Y Clothier R Costi K Campbell D Howie D Solomon L
Full Access

First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone.

Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging.

Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9-71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%).

The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor bone quality. Components without press-fit or three-point fixation were associated with unacceptable amounts of early migration.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_5 | Pages 4 - 4
13 Mar 2023
Burt J AlKandari N Campbell D Maclean J
Full Access

The UK falls behind other European countries in the early detection of Developmental Dysplasia of the hip (DDH) and there remains controversy surrounding screening strategies for early detection. Clinical detection of DDH is challenging and recognised to be dependent on examiner experience. No studies exist assessing the number of personnel currently involved in such assessments.

Our objective was to study the current screening procedure by studying a cohort of new-born babies in one teaching hospital and assess the number of health professionals involved in neonatal hip assessment and the number of examinations undertaken during one period by each individual.

This was a retrospective observational study assessing all babies born consecutively over a 14-week period in 2020. Record of each initial baby check was obtained from Maternity or Neonatal Badger. Follow-up data on ultrasound or orthopaedic outpatient referrals were obtained from clinical records.

1037 babies were examined by 65 individual examiners representing 9 different healthcare professional groups. The range of examinations conducted per examiner was 1- 97 with a mean of 15.9 examinations per person. 49% individuals examined 5 or less babies across the 14 weeks, with 18% only performing 1 examination. Of the 5 babies (0.48%) treated for DDH, one was picked up on neonatal assessment.

In a system where so many examiners are involved in neonatal hip assessment the experience is limited for most examiners. It is unsurprising that high current rates of late presentation of DDH are observed locally, which are in accordance with published national experience.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 102 - 102
23 Feb 2023
Campbell T Hill L Wong H Dow D Stevenson O Tay M Munro JT Young S Monk AP
Full Access

Contemporary indications for unicompartmental knee replacement (UKR) include bone on bone radiographic changes in the medial compartment with relatively preserved lateral and patellofemoral compartments. The role of MRI in identifying candidates for UKR is commonplace. The aim of this study was to assess the relationship between radiographic and MRI pre-operative grade and outcome following UKR.

A retrospective analysis of medial UKR patients from 2017 to 2021. Inclusion criteria were medial UKR for osteoarthritis with pre-operative and post-operative Oxford Knee Scores (OKS), pre-operative radiographs and MRI.

89 patients were included. Whilst all patients had grade 4 ICRS scores on MRI, 36/89 patients had grade 3 KL radiographic scores in the medial compartment, 50/89 had grade 4 KL scores on the medial compartment. Grade 3 KL with grade 4 IRCS medial compartment patients had a mean OKS change of 17.22 (Sd 9.190) meanwhile Grade 4 KL had a mean change of 17.54 (SD 9.001), with no statistical difference in the OKS change score following UKR between these two groups (p=0.873). Medial bone oedema was present in all but one patient. Whilst lateral compartment MRI ICRS scores ranged from 1 to 4 there was no association with MRI score of the lateral compartment and subsequent change in oxford score (P value 0.458). Patellofemoral Compartment (PFC) MRI ICRS ranged from 0 to 4. There was no association between PFC ICRS score and subsequent change in oxford knee score (P value .276)

Radiographs may under report severity of some medial sided knee osteoarthritis. We conclude that in patients with grade 3 KL score that would normally not be considered for UKR, pre-operative MRI might identify grade 4 ICRS scores and this subset of patients have equivalent outcomes to patients with radiographic Grade 4 KL medial compartment osteoarthritis.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 101 - 101
10 Feb 2023
Tan W Yu S Gill T Campbell D Umapathysivam K Smitham P
Full Access

The progressive painful and disabling predicament of patients with severe osteoarthritis awaiting a total hip or knee arthroplasty (THA/TKA) results in a decline in muscle mass, strength and function also known as Sarcopenia.

We conducted a cross-sectional, prospective study of patients on the waiting-list for a THA/TKA in the South Australian public healthcare system and compared the findings to healthy participants and patients newly referred from their general practitioners. Participants with a history of joint replacements, pacemakers and cancers were excluded from this study. Outcomes of this study included (i) sarcopenia screening (SARC-F ≥4); (ii) sarcopenia, defined as low muscle strength (hand grip strength M<27kg; F<16kg), low muscle quality (skeletal muscle index M<27%, F<22.1%) and low physical performance (short physical performance battery ≤8). Additional outcomes include descriptions of the recruitment feasibility, randomisation and suitability of the assessment tools.

29 healthy controls were recruited; following screening, 83% (24/29) met the inclusion criteria and 75% (18/24) were assessed. 42 newly referred patients were recruited; following screening, 67% (30/45) met the inclusion criteria and 63% (19/30) were assessed. 68 waiting list patients were recruited; following recruitment, 24% (16/68) met the inclusion criteria and 75% (12/16) were assessed. Preliminary data shows increasing waiting time is associated with higher SARC-F scores, lower hand grip strength and lower muscle quality.

As a pilot study, preliminary data demonstrate that: (1) study subjects’ willingness to participate will enable a larger study to be conducted to establish the prevalence of sarcopenia and the diagnostic cut-off points for this patient group. (2) SARC-F is a suitable tool to screen for sarcopenia. (3) There is a positive correlation between waiting time for a THA/TKA and sarcopenia.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 48 - 48
10 Feb 2023
Wall C de Steiger R Mulford J Lewis P Campbell D
Full Access

There is growing interest in the peri-operative management of patients with indications for hip and knee arthroplasty in the setting of modifiable risk factors such as morbid obesity, type 2 diabetes mellitus, and smoking. A recent survey of the American Association of Hip and Knee Surgeons (AAHKS) found that 95% of respondents address modifiable risk factors prior to surgery. The aim of this study was to poll Australian arthroplasty surgeons regarding their approach to patients with modifiable risk factors.

The survey tool used in the AAHKS study was adapted for use in the Australian context and distributed to the membership of the Arthroplasty Society of Australia via Survey Monkey.

Seventy-seven survey responses were received, representing a response rate of 64%. The majority of respondents were experienced, high volume arthroplasty surgeons. Overall, 91% of respondents restricted access to arthroplasty for patients with modifiable risk factors. Seventy-two percent of surgeons restricted access for excessive body mass index, 85% for poor diabetic control, and 46% for smoking. Most respondents made decisions based on personal experience or literature review rather than hospital or departmental pressures.

Despite differences in healthcare systems, our findings were similar to those of the AAHKS survey, although their responses were more restrictive in all domains. Differences were noted in responses concerning financial considerations for potentially underprivileged populations. The survey is currently being administered by arthroplasty societies in six other countries, allowing comparison of orthopaedic practice across different healthcare systems around the world.

In conclusion, over 90% of Australian arthroplasty surgeons who responded to the survey address modifiable risk factors prior to surgery.


The Bone & Joint Journal
Vol. 104-B, Issue 12 | Pages 1334 - 1342
1 Dec 2022
Wilcox B Campbell RJ Low A Yeoh T

Aims

Rates of reverse total shoulder arthroplasty (rTSA) continue to grow. Glenoid bone loss and deformity remains a technical challenge to the surgeon and may reduce improvements in patients’ outcomes. However, there is no consensus as to the optimal surgical technique to best reconstruct these patients’ anatomy. This review aims to compare the outcomes of glenoid bone grafting versus augmented glenoid prostheses in the management of glenoid bone loss in primary reverse total shoulder arthroplasty.

Methods

This systematic review and meta-analysis evaluated study-level data in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. We performed searches of Medline (Ovid), Embase (Ovid), and PubMed from their dates of inception to January 2022. From included studies, we analyzed data for preoperative and postoperative range of motion (ROM), patient-reported functional outcomes, and complication rates.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 55 - 55
1 Dec 2022
Nowak L Campbell D Schemitsch EH
Full Access

To describe the longitudinal trends in patients with obesity and Metabolic Syndrome (MetS) undergoing TKA and the associated impact on complications and lengths of hospital stay.

We identified patients who underwent primary TKA between 2006 – 2017 within the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database. We recorded patient demographics, length of stay (LOS), and 30-day major and minor complications. We labelled those with an obese Body Mass Index (BMI ≥ 30), hypertension, and diabetes as having MetS. We evaluated mean BMI, LOS, and 30-day complication rates in all patients, obese patients, and those with MetS from 2006-2017. We used multivariable regression to evaluate the trends in BMI, complications, and LOS over time in all patients and those with MetS, and the effect of BMI and MetS on complication rates and LOS, stratified by year.

270,846 patients underwent primary TKA at hospitals participating in the NSQIP database. 63.71% of patients were obese (n = 172,333), 15.21% were morbidly obese (n = 41,130), and 12.37% met criteria for MetS (n = 33,470). Mean BMI in TKA patients increased at a rate of 0.03 per year (0.02-0.05; p < 0 .0001). Despite this, the rate of adverse events in obese patients decreased: major complications by an odds ratio (OR) of 0.94 (0.93-0.96; p < 0 .0001) and minor complications by 0.94 (0.93-0.95; p < 0 .001). LOS also decreased over time at an average rate of −0.058 days per year (-0.059 to −0.057; p < 0 .0001). The proportion of patients with MetS did not increase, however similar improvements in major complications (OR 0.94 [0.91-0.97] p < 0 .0001), minor complications (OR 0.97 [0.94-1.00]; p < 0 .0330), and LOS (mean −0.055 [-0.056 to −0.054] p < 0 .0001) were found. In morbidly obese patients (BMI ≥ 40), there was a decreased proportion per year (OR 0.989 [0.98-0.994] p < 0 .0001). Factors specifically associated with major complications in obese patients included COPD (OR 1.75 [1.55-2.00] p < 0.0001) and diabetes (OR 1.10 [1.02-1.1] p = 0.017). Hypertension (OR 1.12 [1.03-1.21] p = 0.0079) was associated with minor complications. Similarly, in patients with MetS, major complications were associated with COPD (OR 1.72 [1.35-2.18] p < 0.0001). Neuraxial anesthesia was associated with a lower risk for major complications in the obese cohort (OR 0.87 [0.81-0.92] p < 0.0001). BMI ≥ 40 was associated with a greater risk for minor complications (OR 1.37 [1.26-1.50] p < 0.0001), major complications (1.11 [1.02-1.21] p = 0.015), and increased LOS (+0.08 days [0.07-0.09] p < 0.0001).

Mean BMI in patients undergoing primary TKA increased from 2006 - 2017. MetS comorbidities such as diabetes and hypertension elevated the risk for complications in obese patients. COPD contributed to higher rates of major complications. The obesity-specific risk reduction with spinal anesthesia suggests an improved post-anesthetic clinical course in obese patients with pre-existing pulmonary pathology. Encouragingly, the overall rates of complications and LOS in patients with obesity and MetS exhibited a longitudinal decline. This finding may be related to the decreased proportion of patients with BMI ≥ 40 treated over the same period, possibly the result of quality improvement initiatives aimed at delaying high-risk surgery in morbidly obese patients until healthy weight loss is achieved. These findings may also reflect increased awareness and improved management of these patients and their elevated risk profiles.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 549 - 558
1 May 2022
Duncumb JW Robinson PG Williamson TR Murray IR Campbell D Molyneux SG Duckworth AD

Aims

The purpose of this systematic review was to determine the rates of union for vascularized versus non-vascularized grafting techniques in the operative management of scaphoid nonunion. Secondary aims were to determine the effect of the fixation techniques used, the source of grafting, as well as the influence of fracture location (proximal pole) and avascular necrosis (AVN).

Methods

A search of PubMed, MEDLINE, and Embase was performed in June 2021 using the Preferred Reporting Items for Systematic Review and Meta-Analyses statement and registered using the PROSPERO International prospective register of systematic reviews. The primary outcome was union rate.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 43 - 43
1 Nov 2021
Callary S Abrahams J Zeng Y Clothier R Costi K Campbell D Howie D Solomon L
Full Access

First-time revision acetabular components have a 36% re-revision rate at 10 years in Australia, with subsequent revisions known to have even worse results. Acetabular component migration >1mm at two years following revision THA is a surrogate for long term loosening. This study aimed to measure the migration of porous tantalum components used at revision surgery and investigate the effect of achieving press-fit and/or three-point fixation within acetabular bone.

Between May 2011 and March 2018, 55 patients (56 hips; 30 female, 25 male) underwent acetabular revision THR with a porous tantalum component, with a post-operative CT scan to assess implant to host bone contact achieved and Radiostereometric Analysis (RSA) examinations on day 2, 3 months, 1 and 2 years. A porous tantalum component was used because the defects treated (Paprosky IIa:IIb:IIc:IIIa:IIIb; 2:6:8:22:18; 13 with pelvic discontinuity) were either deemed too large or in a position preventing screw fixation of an implant with low coefficient of friction. Press-fit and three-point fixation of the implant was assessed intra-operatively and on postoperative imaging.

Three-point acetabular fixation was achieved in 51 hips (92%), 34 (62%) of which were press-fit. The mean implant to host bone contact achieved was 36% (range 9–71%). The majority (52/56, 93%) of components demonstrated acceptable early stability. Four components migrated >1mm proximally at two years (1.1, 3.2, 3.6 and 16.4mm). Three of these were in hips with Paprosky IIIB defects, including 2 with pelvic discontinuity. Neither press-fit nor three-point fixation was achieved for these three components and the cup to host bone contact achieved was low (30, 32 and 59%).

The majority of porous tantalum components had acceptable stability at two years following revision surgery despite treating large acetabular defects and poor bone quality. Components without press-fit or three-point fixation were associated with unacceptable amounts of early migration.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_12 | Pages 7 - 7
1 Oct 2021
Semple E Bakhiet A Dalgleish S Campbell D MacLean J
Full Access

Prophylactic pinning of the contralateral hip in unilateral Slipped Upper Femoral Epiphysis (SUFE) persists as a source of debate with the majority of surgeons selecting this option in a proportion of patients whom they regard as at increased risk of a subsequent slip.

Universal prophylactic pinning was introduced in our region in 2005 after an audit of ten years local practice identified 25% of unilateral cases presented with a subsequent slip. This study reports our experience between 2005 and 2020.

In this prospective study, 44 patients presented with 55 affected hips compared with 60 patients with 67 affected hips in the original study. Two patients were excluded as their initial slip had not been treated in our unit. Of the 42 hips seven were bilateral, 34 of the 35 unilateral hips underwent prophylactic pinning. The one exception subsequently underwent prophylactic pinning due to developing pain.

Consistent with our original series, at a minimum follow up of 13 months there have been no complications of infection, fracture, chondrolysis or avascular necrosis subsequent to prophylactic pinning.

Over 25 years 70 patients have undergone prophylactic pinning without complication. On the premise that 25% of our unpinned hips presented with subsequent slips before instituting our policy we estimate that we have prevented 17 subsequent slips over 25 years including the consequences which can be significant. We continue to advocate universal prophylactic pinning as an effective and safe practice in the management of SUFE.


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1595 - 1603
1 Oct 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

In total knee arthroplasty (TKA), blood loss continues internally after surgery is complete. Typically, the total loss over 48 postoperative hours can be around 1,300 ml, with most occurring within the first 24 hours. We hypothesize that the full potential of tranexamic acid (TXA) to decrease TKA blood loss has not yet been harnessed because it is rarely used beyond the intraoperative period, and is usually withheld from ‘high-risk’ patients with a history of thromboembolic, cardiovascular, or cerebrovascular disease, a patient group who would benefit greatly from a reduced blood loss.

Methods

TRAC-24 was a prospective, phase IV, single-centre, open label, parallel group, randomized controlled trial on patients undergoing TKA, including those labelled as high-risk. The primary outcome was indirect calculated blood loss (IBL) at 48 hours. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional 24-hour postoperative oral regime of four 1 g doses, while Group 2 only received the intraoperative dose and Group 3 did not receive any TXA.


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1197 - 1205
1 Jul 2021
Magill P Hill JC Bryce L Martin U Dorman A Hogg R Campbell C Gardner E McFarland M Bell J Benson G Beverland D

Aims

A typical pattern of blood loss associated with total hip arthroplasty (THA) is 200 ml intraoperatively and 1.3 l in the first 48 postoperative hours. Tranexamic acid (TXA) is most commonly given as a single preoperative dose only and is often withheld from patients with a history of thromboembolic disease as they are perceived to be “high-risk” with respect to postoperative venous thromboembolism (VTE). The TRanexamic ACid for 24 hours trial (TRAC-24) aimed to identify if an additional 24-hour postoperative TXA regime could further reduce blood loss beyond a once-only dose at the time of surgery, without excluding these high-risk patients.

Methods

TRAC-24 was a prospective, phase IV, single centre, open label, parallel group, randomized controlled trial (RCT) involving patients undergoing primary unilateral elective THA. The primary outcome measure was the indirect calculated blood loss (IBL) at 48 hours. The patients were randomized into three groups. Group 1 received 1 g intravenous (IV) TXA at the time of surgery and an additional oral regime for 24 hours postoperatively, group 2 only received the intraoperative dose, and group 3 did not receive any TXA.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 21 - 21
1 Mar 2021
Gottschalk M Dawes A Farley K Nazzal E Campbell C Spencer C Daly C Wagner E
Full Access

Perioperative glucocorticoids have been used as a successful non-opioid analgesic adjunct for various orthopaedic procedures. Here we describe an ongoing randomized control trial assessing the efficacy of a post-operative methylprednisolone taper course on immediate post-operative pain and function following surgical distal radius fixation. We hypothesize that a post-operative methylprednisolone taper course following distal radius fracture fixation will lead to improved patient pain and function.

This study is a randomized control trial (NCT03661645) of a group of patients treated surgically for distal radius fractures. Patients were randomly assigned at the time of surgery to receive intraoperative dexamethasone only or intraoperative dexamethasone followed by a 6-day oral methylprednisolone (Medrol) taper course. All patients received the same standardized perioperative pain management protocol. A pain journal was used to record visual analog pain scores (VAS-pain), VAS-nausea, and number of opioid tablets consumed during the first 7 post-operative days (POD). Patients were seen at 2-weeks, 6-weeks, and 12-weeks post-operatively for clinical evaluation and collection of patient reported outcomes (Disabilities of the Arm, Shoulder and Hand Score [qDASH]). Differences in categorical variables were assessed with χ2 or Fischer's exact tests. T-tests or Mann-Whitney-U tests were used to compare continuous data.

Forty-three patients were enrolled from October 2018 to October 2019. 20 patients have been assigned to the control group and 23 patients have been assigned to the treatment group. There were no differences in age (p=0.7259), Body Mass Index (p=0.361), race (p=0.5605), smoking status (p=0.0844), or pre-operative narcotic use (p=0.2276) between cohorts. 83.7% (n=36) of patients were female and the median age was 56.9 years. No differences were seen in pre-operative qDASH (p=0.2359) or pre-operative PRWE (p=0.2329) between groups. In the 7 days following surgery, patients in the control group took an average of 16.3 (±12.02) opioid tablets, while those in the treatment group took an average of 8.71 (±7.61) tablets (p=0.0270). We see that significant difference in Opioid consumption is formed at postoperative day two between the two groups with patients in the control group taking. Patient pain scores decreased uniformly in both groups to post-operative day 7. Patient pain was not statistically from POD0 to POD2 (p=0.0662 to 0.2923). However, from POD4 to POD7 patients receiving the methylprednisolone taper course reported decreased pain (p=0.0021 to 0.0497). There was no difference in qDASH score improvement at 6 or 12 weeks. Additionally, no differences were seen for wrist motion improvement at 6 or 12 weeks.

A methylprednisolone taper course shows promise in reducing acute pain in the immediate post-operative period following distal radius fixation. Furthermore, although no statistically significant reductions in post-operative opioid utilization were noted, current trends may become statistically significant as the study continues. No improvements were seen in wrist motion or qDASH and continued enrollment of patients in this clinical trial will further elucidate the role of methylprednisolone for these outcomes.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 70 - 70
1 Jul 2020
Queen R Schmitt D Campbell J
Full Access

Power production in the terminal stance phase is essential for propelling the body forward during walking and is generated primarily by ankle plantarflexion. Osteoarthritis (OA) of the ankle restricts joint range of motion and is expected to reduce power production at that ankle. This loss of power may be compensated for by unaffected joints on both the ipsilateral and contralateral limbs resulting in overloading of the asymptomatic joints. Total ankle arthroplasty (TAA) has been shown to reduce pain and has the potential to restore range of motion and therefore increase ankle joint power, which could reduce overloading of the unaffected joints and increase walking speed. The purpose of this study was to test the hypothesis that ankle OA causes a loss of power in the affected ankle, compensatory power changes in unaffected lower limb joints, and that TAA will increase ankle power in the repaired ankle and reduce compensatory changes in other joints.

One hundred and eighty-three patients (86 men, 97 women with average ages 64.1 and 62.4 years respectively) requiring surgical intervention for ankle OA were prospectively enrolled. Implant selection of either a fixed (INBONE or Salto Talaris) or mobile (STAR) bearing implant was based on surgeon preference. Three-dimensional kinematics and kinetics were collected prior to surgery and one year post-operatively during self-selected speed level walking using an eight-camera motion capture system and a series of force platforms. Subject walking speed and lower extremity joint power during the last third of stance at the ankle, knee, and hip were calculated bilaterally and compared before and after surgical intervention across the entire group and by implant type (fixed vs. mobile), and gender using a series of ANOVAs (JMP SAS, Cary, NC), with statistical significance defined as p < 0 .05.

There were no gender differences in age, walking speed, or joint power. All patients increased walking as a result of surgery (0.87 m/s±0.26 prior to surgery and 1.13 m/s±0.24 after surgery, p < 0 .001) and increased total limb power. Normalized to total power (which accounts for changes in speed and distribution of power production across joints), prior to surgery the affected ankle contributed 19%±10% of total power while the unaffected ankle contributed 42%±12% (P < 0 .001). After surgery, the affected ankle increased to 25%±9% of total power and the unaffected ankle decreased to 38%±9% of total (P < 0.001). Other joints showed no significant power changes following surgery. Fixed bearing implants provide greater surgical ankle power improvement (61% versus 29% increase, p < 0 .002). Much of that change was due to the fact that those that received fixed-bearing implants had significantly lower walking speed and power before surgery.

Ankle OA reduced ankle power production, which was partially compensated for by the unaffected ankle. TAA increases walking speed and power at the affected ankle while lowering power production on the unaffected side. The modifications in power production could lead to increased physical activity and reduced overloading of asymptomatic joints.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 11 - 11
1 Jul 2020
Magill P Hill J Bryce L Dorman A Hogg R Campbell C Benson G Beverland D
Full Access

Background

91% of blood loss in Total Hip Replacement (THR) occurs in the period after skin closure and the first 24 post-operative hours. TRAC-24 was established to identify if an additional 24-hour post-operative oral regime of Tranexamic acid (TXA) is superior to a once-only intravenous dose at surgery.

Methods

This was a prospective, phase IV, single centered, open label, parallel group controlled trial on patients undergoing primary elective THR. A history of thromboembolic or cardiovascular disease were not exclusion criteria. The primary outcome was indirect calculated blood loss at 48 hours (IBL). 534 patients were randomized on a 2:2:1 ratio over three different groups. Group 1 received an intravenous dose of TXA at the time of surgery and an additional 24-hour post-operative oral regime, Group 2 only received the intra-operative dose and Group 3 did not receive any TXA.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 37 - 37
1 Jul 2020
Mann S Tohidi M Harrison MM Campbell A Lajkosz K VanDenKerkhof E
Full Access

The purpose of this population-based study was to determine the association between morbid obesity and 10-year mortality and complications in patients undergoing primary THA.

A cohort study of 22,251 patients, aged 45–74 years old, treated with primary THA between 2002 and 2007 for osteoarthritis, was conducted using Ontario administrative healthcare databases. Patients were followed for 10 years. Risk ratios (RRs) of mortality, reoperation, revision, and dislocation in patients with body mass index (BMI) > 45 kg/m2(morbidly obese patients) compared with BMI ≤45 kg/m2 (non-morbidly obese) were estimated.

3.3% of the cohort (726) was morbidly obese. Morbidly obese patients were younger (mean age 60.6 vs. 63.3, P-value < 0 .001) and more likely to be female (63.9% vs. 52.2%, P-value < 0 .001), compared with non-morbidly obese patients. Morbid obesity was associated with higher 10-year risk of death (RR 1.38, 95% CI 1.18, 1.62). Risks of revision (RR 1.43, 95% CI 0.96, 2.13) and dislocation (RR 2.38, 95% CI 1.38, 4.10) were higher in morbidly obese men, compared with non-morbidly obese men, there were no associations between obesity and revision or dislocation in women. Risk of reoperation was higher in morbidly obese women, compared to non-morbidly obese women (RR 1.60, 95% CI 1.05, 2.40), there was no association between obesity and reoperation in men.

Morbidly obese patients undergoing primary THA are at higher risks of long-term mortality and complications. There were differences in complication risk by sex. Results should inform evidence-based perioperative counseling of morbidly obese patients considering THA.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_10 | Pages 25 - 25
1 Oct 2019
Saunders B Hill J Foster N Cooper V Protheroe J Chudyk A Chew-Graham C Campbell P Bartlam B
Full Access

Background

Improving primary care management of musculoskeletal (MSK) pain is a priority. A pilot cluster RCT tested prognostic stratified care for patients with common MSK pain presentations, including low back pain, in 8 UK general practices (4 stratified care; 4 usual care) with 524 patients. GPs in stratified care practices were asked to use i) the Keele STarT MSK tool for risk-stratification and ii) matched treatment options for patients at low-, medium- and high-risk of persistent pain. A linked qualitative process evaluation explored patients' and GPs' views and experiences of stratified care.

Methods

Individual ‘stimulated-recall’ interviews with patients and GPs in the stratified care arm (n=10 patients; 10 GPs), prompted by consultation-recordings. Data were analysed thematically and mapped onto the COM-B behaviour change model; exploring the Opportunity, Capability and Motivation GPs and patients had to engage with stratified care.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_9 | Pages 25 - 25
1 Sep 2019
Williams F Palmer M Tsepilov Y Freidin M Boer C Yau M Evans D Gelemanovic A Bartz T Nethander M Arbeeva L Karssen L Neogi T Campbell A Mellstrom D Ohlsson C Marshall L Orwoll E Uitterlinden A Rotter J Lauc G Psaty B Karlsson M Lane N Jarvik G Polasek O Hochberg M Jordan J van Meurs J Jackson R Nielson C Mitchell B Smith B Hayward C Smith N Aulchenko Y Suri P
Full Access

Purpose

Back pain is the primary cause of disability worldwide yet surprisingly little is known of the underlying pathobiology. We conducted a genome-wide association study (GWAS) meta-analysis of chronic back pain (CBP). Adults of European ancestry from 15 cohorts in the Cohorts for Heart and Aging Research in Genomic Epidemiology (CHARGE) consortium, and UK Biobank were studied.

Methods

CBP cases were defined as reporting back pain present for ≥3–6 months; non-cases were included as comparisons (“controls”). Each cohort conducted genotyping followed by imputation. GWAS used logistic regression with additive genetic effects adjusting for age, sex, study-specific covariates, and population substructure. Suggestive (p<5×10–7) & genome-wide significant (p<5×10–8) variants were carried forward for replication in an independent sample of UK Biobank participants. Discovery sample n = 158,025 individuals, including 29,531 CBP cases.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2019
Campbell P Kung MS Park SH
Full Access

Background

Distal femoral replacements (DFR) are used in children for limb-salvage procedures after bone tumor surgery. These are typically modular devices involving a hinged knee axle that has peripheral metal-on-polyethylene (MoP) and central metal-on-metal (M-M) articulations. While modular connections and M-M surfaces in hip devices have been extensively studied, little is known about long-term wear or corrosion mechanisms of DFRs. Retrieved axles were examined to identify common features and patterns of surface damage, wear and corrosion.

Methods

The cobalt chromium alloy axle components from 13 retrieved DFRs were cleaned and examined by eye and with a stereo microscope up to 1000× magnification. Each axle was marked into 6 zones for visual inspection: the proximal and distal views, and the middle (M-M) and 2 peripheral (MoP) zones. The approximate percentage of the following features were recorded per zone: polishing, abrasion or scratching, gouges or detectable wear, impingement wear (i.e. from non- intentional articulation), discoloration and pitting.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 8 - 8
1 Apr 2019
Wilson C Critchely O Callary S Campbell D
Full Access

Introduction & aims

The magnitude and pattern of acceptable migration in clinically successful cementless stems is not well understood. Radiostereometric analysis (RSA) is a well-recognised method of assessing implant migration.

Previous studies have reported long term RSA results for cemented stems. The aim of this study was to assess the long-term migration characteristics of the Corail hydroxyapatite-coated cementless stem at 10 years using RSA.

Method

A prospective cohort of 30 patients undergoing primary total hip arthroplasty for primary hip osteoarthritis were enrolled into a study to characterise the migration behaviour of a cementless stem. Tantalum markers were attached to the stem and placed in the bone intraoperatively, allowing for RSA measurements to be taken in vivo. Previous 5-year results have been presented.

A total of 14 patients (total 15 hips, one bilateral) with mean age 82 years (range, 69–92 years) underwent repeat long-term RSA radiographs at minimum 10 years post op. The mean time to follow up was 13.9 years (range, 13.3–14.4 years). The RSA radiographs were analysed to assess for implant rotation and translation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_18 | Pages 6 - 6
1 Dec 2018
Semple E Campbell D Maclean J
Full Access

Historically avoidance of avascular necrosis (AVN) has been the primary objective in the management of an acute unstable slipped upper femoral epiphysis (SUFE). When achieved through pinning in situ it was invariably associated with significant malunion. With increasing appreciation of the consequences of femoroacetabular impingement, modern techniques aim to correct deformity and avoid AVN.

Exactly what constitutes an acute unstable SUFE is a source of debate but should represent 5–10% of all cases.

This audit reviewed cases over the past 25 years treated in one region. Of 89 patients with 113 slips, 21 hips were recorded as unstable. During this period the management has evolved from closed reduction and stabilization through pinning in situ, to open reduction.

Radiographic outcomes following these three treatment methods were compared with record of any subsequent surgery in the form of osteotomy or total hip arthroplasty.

Currently the lowest reported incidence of AVN in patients with an acute unstable slip is associated with the Parsch technique which combines open arthrotomy, digital reduction and screw fixation. Early outcomes with this technique are in accordance with those reported in the literature and represents a significant improvement in outcome when compared to earlier techniques used in the management of the severe unstable SUFE.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 19 - 19
1 Oct 2018
Campbell P Park S Lu Z Ebramzadeh E
Full Access

Introduction

In 2010, a widely used metal-on-metal hip implant was voluntarily recalled from the market by the manufacturer. Our lab performed detailed retrieval analysis of 548 of the explanted devices and 165 periprosthetic tissue specimens. We reported a high degree of variability in the multiple measurements that we performed on the components, including volumetric wear.

Other studies using semi-quantitative tissue grading methods to describe the histology of the periprosthetic tissues from metal-on-metal hips have looked for relationships between component wear and histological features. Grammatopoulos et al found higher ALVAL scores in 45 hip resurfacing patients with pseudotumors compared to 11 without pseudotumors and a moderately positive correlation between wear and the histological rankings for tissue necrosis and lymphocytic response.

We examined correlations between the component wear measurements from retrieval analysis and the tissue features in this large group of one metal-on-metal hip design.

Materials and Methods

Tissues were processed routinely into paraffin sections, stained with H&E and characterized with light microscopic semi-quantitative scores for ALVAL features and for the number of macrophages and lymphocytes, extent of metal debris and the estimated percentage of necrosis per slide. Spearman correlation analysis was conducted to evaluate any correlations between retrieval wear measurements and histological findings.


Bone & Joint 360
Vol. 7, Issue 3 | Pages 2 - 6
1 Jun 2018
Mayne AIW Campbell DM


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 23 - 23
1 May 2018
Jenkinson M Arnall F Campbell J Meek R
Full Access

Since the introduction of national guidelines in 2009 encouraging the use of total hip arthroplasty (THA) to treat intracapsular neck of femur fractures there has been no population-based studies into the surgical outcomes for this indication. This study aims to calculate the complication rates for THA when performed for a fractured neck of femur and compare them to THA performed for primary osteoarthritis in the same population.

The Scottish Arthroplasty Project was used to identify all THAs performed in Scotland for neck of femur fracture and osteoarthritis between 1st of January 2009 and 31st December 2014. Dislocation, infection and revision rates at 1 year were calculated.

The rate of dislocation, infection and revision at 1 year were all significantly increased among the fracture neck of femur cohort. In total 44046 THAs were performed, 38316 for OA and 2715 for a neck of femur fracture. 2.1% of patients (n=57) who underwent a THA for a neck of femur fracture suffered a dislocation in the 1st year postoperatively, compared to 0.9% (n=337) when the THA was performed for osteoarthritis. Relative Risk of dislocation: 2.3870 (95% C.I. 1.8077–3.1252, p value <0.0001). Relative Risk of infection: 1.4561 (95% C.I. 1.0496–2.0200, p value 0.0245) Relative Risk of revision: 1.4807 (95% C.I. 1.0308–2.1268, p value 0.0336).

This is the first time a dislocation rate for THA performed for a neck of femur fracture has been calculated for an entire population. As the number of THAs for neck of femur fracture increases this dislocation rate will have clinical implications.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 4 - 4
1 Apr 2018
Baetz J Messer P Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION

Loosening is a major cause for revision in uncemented hip prostheses due to insufficient primary stability. Primary stability after surgery is achieved through press-fit in an undersized cavity. Cavity preparation is performed either by extraction (removing bone) or compaction (crushing bone) broaching. Densification of trabecular bone has been shown to enhance primary stability in human femora; however, the effect of clinically used compaction and extraction broaches on human bone with varying bone mineral density (BMD) has not yet been quantified. The purpose of this study was to determine the influence of the broach design and BMD on the level of densification at the bone-cavity interface, stem seating, the bone-implant contact area and the press-fit achieved.

METHODS

Paired human femora (m/f=11/12, age=60±18 y) were scanned with quantitative computed tomography (QCT, Philips Brilliance 16) before broaching, with the final broach, after its removal and after stem implantation. Compaction broaching (n=4) was compared in an in situ (cadaver) study against extraction broaching with blunt tooth types (n=3); in an ex situ (excised femora) study, compaction broaching was compared against extraction broaching with sharp tooth types (n=8 each). QCT data were resampled to voxel sizes of 1×1×1 mm (in situ) and 0.5×0.5×1 mm (ex situ). Mean trabecular BMD of the proximal femur was determined. The cavity volumes were segmented in the post-broach images (threshold: −250 mgHA/cm3, Avizo 9.2) and a volume of interest (VOI) of one-voxel thickness was added around the cavity to capture the interfacial bone. VOIs were transferred to the pre-broach image and bone densification was calculated within each VOI as the increase from pre- to post-broach image (MATLAB). Detailed surface data sets of broaches and stems were collected with a 3D laser-scanner (Creaform Handyscan 700) and aligned with the segmented components in the CT scans (Fig. 1). Stem seating was defined as the difference between the top edge of the stem coating and the final broach. Distance maps between the stem and cavity surface were generated to determine the bone-implant contact area and press-fit. All parameters were analysed between 5 mm distal to the coating and 1 cm distal to the lesser trochanter and analysed with related-samples Wilcoxon signed rank and Spearman's correlation tests (IBM SPSS Statistics 22).


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 92 - 92
1 Apr 2018
Messer P Baetz J Lampe F Pueschel K Klein A Morlock M Campbell G
Full Access

INTRODUCTION

The restoration of the anatomical hip rotation center (HRC) has a major influence on the longevity of hip prostheses. Deviations from the HRC of the anatomical joint after total hip arthroplasty (THA) can lead to increased hip joint forces, early wear or loosening of the implant. The contact conditions of acetabular press-fit cups after implantation, including the degree of press-fit, the existence of a polar gap and cup orientation, may affect the HRC restoration, and therefore implant stability. The aim of this study was to determine the influence of acetabular press-fit, polar gap and cup orientation on HRC restoration during THA.

METHODS

THAs were performed by an experienced orthopaedic surgeon in full cadaveric models simulating real patient surgery (n=7). Acetabular cups with a Porocoat™ (n=3) and Gription™ surface coating (n=4) were implanted (DePuy Synthes, Leeds, UK). Computed tomography (CT) scans prior to surgery, as well as after reaming and implantation of press-fit cups were used to calculate the HRC displacement. After aligning the pelves in the anterior pelvic plane, 3D reconstruction of the HRC at each stage was performed by fitting spheres to the femoral head, the reamed cavity and the inserted cup. 3D surface models of the cups were generated using a laser scanner and were registered to the CT images. The effective press-fit was calculated using the diameters of spheres, fitted to the cavity prior to cup insertion and to the outer cup coating. The polar gap was defined as the difference between the outer cup surface and the subchondral bone at the cup pole. Anteversion and abduction angles were calculated as difference between the cup planes and the sagittal and transverse plane, respectively.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_2 | Pages 1 - 1
1 Feb 2018
Chen Y Campbell P Strauss V Foster N Jordan K Dunn K
Full Access

Background and objectives

Low back pain (LBP) is a major health challenge globally. Research has identified common trajectories of pain over time. We aimed to investigate whether trajectories described in one primary care cohort can be confirmed in another, and to determine the prognostic value of factors collected 5 years prior to the identification of the trajectory.

Methods and results

The study was carried out on 281 patients who had consulted primary care for LBP, at that point completed a baseline questionnaire, and then returned a questionnaire at 5-years follow-up plus at least 3 (of 6) subsequent monthly questionnaires. Baseline factors were measured using validated tools. Pain intensity scores from the 5-year follow-up and monthly questionnaires were used to cluster participants into 4 previously derived pain trajectories (no or occasional mild, persistent mild, fluctuating, persistent severe), using latent class analysis. Posterior probabilities of belonging to each cluster were estimated for each participant. The posterior probabilities for the assigned clusters were very high (>0.90) for each cluster except for the smallest ‘fluctuating’ cluster (0.74). Lower social class (OR 2.9; 95% CI 1.2, 7.0), higher pain intensity (1.6 per unit; 1.2, 2.2), and pain duration greater than 3 years (2.7; 1.0, 7.3), were significantly associated with a more severe trajectory 5-years later, as were higher physical disability, emotional impact of pain, and perception pain will last a long time.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_18 | Pages 12 - 12
1 Nov 2017
Reidy M Faulkner A Grupping R Mayne A Campbell D MacLean J
Full Access

Prophylactic fixation of the contralateral hip in cases of unilateral slipped capital femoral epiphysis (SCFE) remains contentious. Our senior author reported a 10 year series in 2006 that identified a rate of subsequent contralateral slip of 25percnt; when prophylactic fixation was not performed. This led to a change in local practice and employment of prophylactic fixation as standard. We report the 10 year outcomes following this change in practice.

A prospective study of all patients who presented with diagnosis of SCFE between 2004 and 2014 in our region. Intra-operative complication and post-operative complication were the primary outcomes. 31 patients presented during the study period: 16 male patients and 15 female patients. The mean age was 12.16 (8–16, SD 2.07). 25 patients had stable SCFE and 5 had unstable SCFE. Stability was uncertain in 1 patient. 25 patients had unilateral SCFE and 6 had bilateral SCFE. 24 patients who had unilateral SUFE had contralateral pinning performed. 1 unilateral SCFE did not have contralateral pinning performed as there was partial fusion of physis on contralateral side.

In the hips fixed prophylactically there was 1 cases of transient intraoperative screw penetration into the joint and 1 case of minor wound dehiscence. There were no cases or chondrolysis or AVN. There were no further contralateral slips. This change in practice has been adopted with minimal complication. The fixation of the contralateral side is not without risk but by adopting this model the risk of subsequent slip has been reduced from 25percnt; to 0percnt;.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_18 | Pages 14 - 14
1 Nov 2017
Gill S Campbell D
Full Access

Training time in Trauma & Orthopaedics is pressured. In this action research project, we develop a feedback/self-reflection model for trainers and trainees, emphasising the contribution both groups make to training, to maximise cohesion and efficacy.

Starting in 2013, trainees completed anonymous feedback forms after each 6-month post. The 18-point quantitative questionnaire covers four training domains: WBA engagement, teaching/feedback, research/audit, operative training.

Consultant trainers completed a once-off corresponding 18-point self-reflection questionnaire. Additionally, trainers were asked for their expectations of and advice for trainees.

Individual trainer profiles were generated from trainee feedback questionnaires, allowing comparison between trainer-group-average, trainer-specific and trainer-self-reflection scores across 18 fields. Trainer profiles were uploaded to ISCP and used for recognition of trainer status for SOAR. This data provided basis for local service provision review with amendments to maximise training efficacy.

Results of thematic analysis of trainer feedback was shared with the trainee group. This and subsequent group self-reflection formed the basis of our ‘Trainee Charter’.

Trainee feedback illustrates high levels of satisfaction with local training (average global score 4.2/5). Strengths included ‘feedback’ and ‘operative teaching’; relative weaknesses included ‘research time’ and ‘OPD teaching’.

The ‘Trainee Charter’ details specific desirable behaviours that embody eight trainee-qualities consistently identified by trainers as important, including ‘honesty’ and ‘being organised’. The charter emphasises trainee contribution to training.

For the first time, trainers have the benefit of serial and individualised feedback. Trainees are better informed and empowered in relation to maximising their own training. Most importantly, both halves of the training-team are explicitly acknowledged.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_19 | Pages 6 - 6
1 Nov 2017
Reidy M Collins C MacLean J Campbell D
Full Access

Following the neonatal examination the 6–8 week ‘GP check’ forms the second part of selective surveillance for developmental dysplasia of the hip (DDH) in the UK. We aim to investigate the effectiveness of this 6–8 week examination for DDH.

This is a observational study including all infants born in our region over 5 years. Early presentation was defined as diagnosis within 14 weeks of birth and late presentation after 14 weeks. Treatment record for early and late DDH as well as referrals for ultrasound (US) following the 6–8 week check were analysed. The attendance at the 6–8 week examination in those patients who went on to present with a late DDH was also analysed.

23112 live births, there were 141 confirmed cases of DDH. 400 referrals for ultrasound were received from GP; 6 of these had a positive finding of DDH. 27 patients presented after 14 weeks and were classified as late presentations. 25 of these patients had attended the 6–8 week examination and no abnormality had been identified. The sensitivity of the examination was 19.4%, its specificity was 98% and it had a positive predictive value of 1.5%

For many years the 6–8 week ‘check’ has been thought of as a safety net for those children with DDH not identified as neonates, however we found that 4 out of every 5 children with DDH were not identified. It is essential efforts are made to impove detection as the long term consequences of late presentation can be life changing.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 57 - 57
1 Feb 2017
Campbell P Yuan N Luck J Courpron P Park S
Full Access

Recently, a special type of surface pitting found on metal implants was proposed to arise from “inflammatory cell-induced” corrosion (ICI, Figure 1) (1, 2). The actual mechanism of this was unknown, but similar features were suggested to be artefacts of electrocautery damage from revision surgery (3). Under lab conditions and without the influence of any cells, we aimed to reproduce the same surface pits and structures with electrocautery.

Methods

A polished cobalt-chromium disk (40 mm diameter, 8 mm thick) was marked into 8 sections for various testing conditions (Figure 2a). A stainless steel Bovie tip with a unipolar electrocautery machine (SYSTEM 5000, ConMed, USA) was used at typical surgical coagulation conditions: (70 volt, 120 watts, 562 KHz frequency). We mimicked three types of surgical techniques with the electrocautery: “Dotting” was repeated, on and off, direct surface contact; “Dragging” was constant, direct surface contact; “Hovering” was pausing several millimeters above the surface. We also examined the interplay of these practices on diamond-tip-induced scratches and either dry or wet (normal saline) conditions. High magnification images (Keyence VHX-2000E) were taken after the disk was cleaned with laboratory soap, light mechanical scrubbing, and formalin soak.

Results

Coagulation mode generated electrical sparks when dotting/dragging and electrical arcs when hovering. These left seared marks that persisted even after cleaning (Figure 2b). At higher magnification, the surface features were comparable in size and shape to those attributed to ICI (1, 2). Areas wet with saline (Figure 3a) showed an abundance of ringed pits with raised edges that closely resembled those observed in Figure 1. Furthermore we obtained images similar to the phenomenon of “cellular tracks” (Figure 3b) (1). Premade scratches did not influence the pit arrangement but scratches made by the Bovie tip produced the characteristic scratch-associated ICI features as observed on implant retrievals in the past (Figure 3c) (4).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 59 - 59
1 Feb 2017
Campbell D Sharpe K Cohen R
Full Access

Introduction

Cementless tapered wedge stems have shown excellent results over the last decade. Distal potting with inadequate proximal fit, as well as failure to achieve biologic fixation has led to thigh pain, loosening and implant failure. To support a variety of patient morphologies a novel tapered wedge stem was designed with reduced distal morphology, maximizing the proximal contact of the grit blasted surface. The objective of the study was to analyze the clinical outcomes of this stem design.

Methods

Three hundred and nineteen patients enrolled into prospective, post-market multicenter studies received a novel tapered wedge stem. Clinical and patient-reported outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and Euroqol 5D Score (EQ-5D) were evaluated preoperative through two years postoperative.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 55 - 55
1 Feb 2017
Brozyniak C Hitt K Della Valle C Campbell D
Full Access

INTRODUCTION

As the demographic of the patient population requiring revision total knee arthroplasty (rTKA) continues to expand, varying preoperative conditions and activity levels need to be taken into consideration when analyzing postoperative outcomes. Factoring in preoperative activity levels can help manage the expectations of patients. The purpose of this study was to analyze the outcomes of low and high activity patients receiving a contemporary rTKA.

METHODS

One hundred and eighty rTKA patients enrolled in a prospective, multicenter study were evaluated through 2 years postoperative. Patients were divided into groups based on preoperative activity level using the Lower Extremity Activity Scale (LEAS). Patients scoring between 1–7 were classified as ‘Low Activity’ (LA, N=104) and patients scoring 8–18 were classified as ‘High Activity’ (HA, N=76). Clinical and patient-reported outcomes were evaluated, with an additional quality of life analysis completed utilizing SF-6D scores obtained by transforming SF-36 scores through a method described by Brazier et al. and analyzed for effect size.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 85 - 85
1 Feb 2017
Cruz A Perona P Cohen R Campbell D
Full Access

Background

Instability and dislocation are some of the most important postoperative complications and potential causes of failure that dual mobility total hip arthroplasty (THA) systems continue to address. Studies have shown that increasing the relative head size provides patients implanted with smaller and larger cups increased stability, greater ROM and a lesser incidence of impingement, without compromising clinical results. The purpose of the current study was to review clinical outcomes in three groups of primary THA patients receiving a dual mobility acetabular shell.

Methods

In two US based, post-market, multicenter studies, 450 patients received a primary cementless dual mobility THA. Patients were split into three groups based on cup size: ≤ 50mm, 52mm–56mm, and ≥ 58mm. Harris Hip Scores (HHS), Short Form 12 Physical Components (SF12 PCS), Lower Extremity Activity Scores (LEAS), and Euroqol 5D Score (EQ-5Ds) were collected preoperatively and through 2 years postoperative.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 60 - 60
1 Feb 2017
Vanacore C Masini M Westrich G Campbell D Robinson K
Full Access

Introduction

Acetabular revision surgery remains a technically demanding procedure with higher failure rates than primary total hip arthroplasty (THA). An acetabular component with three dimensional porous titanium and anatomic screw holes (Figure 1) was designed to allow the cup to be positioned anatomically and provide reliable fixation.

Methods

A prospective multicenter study of 193 cases (190 patients) was conducted to assess the midterm clinical outcomes of the revision titanium acetabular shell. Radiographs, demographics, Harris Hip Score (HHS), and Short Form 36 (SF-36) were collected preoperatively, at 6 weeks, 3 months, and annually thereafter to 5 years. The mean duration of follow-up was 3.36 years. The Paprosky classification was assessed intraoperatively. Short Form 6D (SF-6D) utility values were obtained by transforming SF-36 scores through the Brazier method and were analyzed for effect size.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 61 - 61
1 Feb 2017
Campbell D Izant T Valentino E
Full Access

1) INTRODUCTION

Acetabular fixation in cementless total hip arthroplasty (THA) relies on new technology for stability and survivorship of the implant. A highly porous 3D titanium coating was developed with a biologically inspired pore structure to improve initial friction fixation with mechanical stability and long term biological fixation. Ongoing research is investigating potential radiographic phenomenons these coatings produce, resulting in the presence of lucent lines. The purpose of this study was to evaluate clinical and radiographic outcomes of a 3D highly porous-coated titanium acetabular shell.

2) METHODS

One hundred and sixty-two cases as part of a non-randomized, post-market, multicenter study received a primary cementless THA. Clinical outcomes including the Harris Hip Score (HHS), Lower Extremity Activity Scale (LEAS), Short Form 12 (SF12), and EuroQol 5D Score (EQ-5D) were collected preoperatively and at six weeks, one year postoperative. Additionally, radiographs, radiographic parameters and techniques were analyzed for institutional differences.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 58 - 58
1 Feb 2017
Campbell P Yuan N Ebramzadeh E
Full Access

Young osteoarthritic male patients have been considered the ideal candidates for Metal-on-Metal (MoM) hip resurfacing arthroplasty (HRA), based on generally good long term results. In contrast, hip resurfacing in young female patients has become controversial. Recently, one implant manufacturer withdrew 46mm and smaller components, citing poorer than expected 10 year outcomes in females with smaller HRAs. Whether this difference is related to gender or to component size is still debated. Possible reasons for higher failure rates reported in females include higher rates of hip dysplasia, poorer bone quality and the risk of higher wear in some smaller sized implants with low cup coverage angles.

We reviewed HRA revision specimens with the aim of comparing mode of failure, time to revision, femoral cement characteristics and acetabular bone attachment in specimens larger and smaller than 46mm and from male versus female patients.

Methods

The study included all of the MoM HRA devices in our collection. Of the 284 hip resurfacing devices with complete clinical information, 131 were from male and 153 from female patients. Femoral sizes ranged from 36 – 58mm, median and mode 46mm; median size in females was 44 and 50mm in males. Time to failure ranged from 1 to 178 months, median 24 mos. Seven designs were represented but the majority were Conserve Plus (n=105 WMT, USA) and BHR (n=78 Smith & Nephew, USA) which differ in cementing technique. 131 femoral components were sectioned and the width of the cement mantle and the amount of cement in the head were measured. Where available, the amount of bone attached to the cup porous surface (n=91), tissue ALVAL scores (n=75) and bearing wear depth (n=138) were included in the multivariate analysis.

Results

As a function of gender, there were no significant differences in time to revision, cement measurements or ALVAL scores. Wear depth was significantly higher in females (femoral 41um vs 21um; cup 50um vs 16um, p=0.05). As a function of size (46 and less = small), the <46mm group had a slightly shorter time to revision, 30 vs 38 months, p=0.04). Bone ingrowth ranged from 0 to 60% (Figure 1) and significantly less bone attachment was noted in both the smaller and larger components (p = 0.001). Other characteristics were similar in both groups. When wear-related failure modes (cup malposition, lysis, high ions) were compared, no differences between male and female or large vs small were found. The amount of cement in the femoral heads covered a wide range but femoral loosening or fracture rates were not different as a function of size or gender.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 17 - 17
1 Jan 2017
Deluzio K Brandon S Clouthier A Hassan E Campbell A
Full Access

Valgus unloader knee braces are a conservative treatment option for medial compartment knee osteoarthritis (OA). These braces are designed to reduce painful, and potentially injurious compressive loading on the damaged medial side of the joint through application of a frontal-plane abduction moment. While some patients experience improvements in pain, function, and joint loading, others see little to no benefit from bracing [1]. Previous biomechanical studies investigating the mechanical effectiveness of bracing have been limited in either their musculoskeletal detail [2] or incorporation of altered external joint moments and forces [3]. The first objective was to model the relative contributions of gait dynamics, muscle forces, and the external brace abduction moment to reducing medial compartment knee loads. The second objective was to determine what factors predict the effectiveness of the valgus unloading brace.

Seventeen people with knee OA (8 Female age 54.4 +/− 4.2, BMI 30.00 +/− 4.0 kg/m2, Kellgren-Lawrence range of 1–4 with med. = 3) and 20 healthy age-matched controls participated in this study which was approved by the institutional ethics review board. Subjects walked across a 20m walkway with and without a Donjoy OA Assist knee brace while marker trajectories, ground reaction forces, and lower limb electromyography were recorded. The external moment applied by the brace was estimated by multiplying the brace deformation by is pre-determined brace-stiffness. For each subject, a representative stride was selected for each brace condition. A generic musculokeletal model with two legs, a torso, and 96 muscles was modified to include subject-specific frontal plane alignment and medial and lateral contact locations [4]. Muscle forces, and tibiofemoral contact forces were estimated using static optimization [4]. We defined brace effectiveness as the difference in the peak medial contact force between the braced and the unbraced conditions. A stepwise regression analysis was performed to predict brace effectiveness based on: X-ray frontal plane alignment, medial joint space, KL grade, mass, WOMAC scores, unbraced walking speed, trunk, hip and knee joint angles and moments.

The OA Assist brace reduced medial joint loading by approximately 0.1 to 0.2 BW or roughly 10%, during stance. This decrease was primarily due to the external brace abduction moment, and not changes in gait dynamics, or muscle forces. The brace effectiveness could be predicted (R2=0.77) by the KL grade, and the magnitude of the hip adduction moment in early stance (unbraced). The brace was more effective for those that had larger hip adduction moments and for those with more severe OA.

The valgus knee brace was found to reduce the medial joint contact force by approximately 10% as estimated using a musculoskeletal model. Bracing resulted in a greater reduction in joint contact force for those who had more severe OA while still maintaining a hip adduction moment similar to that of healthy controls.


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 107 - 115
1 Jan 2017
Carr A Cooper C Campbell MK Rees J Moser J Beard DJ Fitzpatrick R Gray A Dawson J Murphy J Bruhn H Cooper D Ramsay C

Aims

The appropriate management for patients with a degenerative tear of the rotator cuff remains controversial, but operative treatment, particularly arthroscopic surgery, is increasingly being used. Our aim in this paper was to compare the effectiveness of arthroscopic with open repair of the rotator cuff.

Patients and Methods

A total of 273 patients were recruited to a randomised comparison trial (136 to arthroscopic surgery and 137 to open surgery) from 19 teaching and general hospitals in the United Kingdom. The surgeons used their usual preferred method of repair. The Oxford Shoulder Score (OSS), two years post-operatively, was the primary outcome measure. Imaging of the shoulder was performed at one year after surgery. The trial is registered with Current Controlled Trials, ISRCTN97804283.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1604 - 1610
1 Dec 2016
Callary SA Field JR Campbell DG

Aims

The increased in vivo resistance to wear of highly crosslinked polyethylene (HXLPE) in total hip arthroplasty (THA) has led to an increased use of larger articulations which have been shown to reduce the incidence of early dislocation. To date, there are few reports of the wear of larger articulations using second generation HXLPE liners. Our prospective cohort study measured the bedding-in and early wear of large (36 mm and 40 mm diameter) articulations involving a second generation X3 HXLPE liner and compared our findings with previous clinical and in vitro studies of the same material.

Patients and Methods

The proximal penetration of the femoral head five years post-operatively was measured for 15 patients using radiostereometric analysis (RSA).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_12 | Pages 11 - 11
1 Jun 2016
Makaram N Arnold G Wang W Campbell D Gibbs S Abboud R
Full Access

Introduction

There is limited evidence assessing the effect of the Ankle Foot Orthosis (AFO) on gait improvements in diplegic cerebral palsy. In particular, the effect of the AFO on vertical forces during gait has not been reported. Appropriate vertical ground reaction forces are crucial in enabling children with CP to walk efficiently. This study investigated the effect of AFO application on the vertical forces in gait, particularly the second vertical peak in force (FZ2) in late stance. The force data was compared with the barefoot walk.

Patients and Methods

A retrospective analysis of nineteen children (8M,11F) who met inclusion criteria of a diagnosis of spastic diplegic CP, ability to walk independently barefoot and also using bilateral rigid AFOs were included. Gait data were acquired using the Vicon-Nexus ® motion-capture. Resulting ground reaction force data were recorded. Appropriate statistical methods assessed significance between barefoot and AFO data


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 18 - 18
1 May 2016
Anderson J Campbell P Nelson S
Full Access

Avascular necrosis of the femoral head (AVN) is associated with collapse of the femoral head and arthritic degeneration of the joint. The combination of an implant inserted into the femoral head that provides mechanical support and bone grafting to promote bone formation may offer a possible joint-preserving solution1. Seventeen such procedures were performed between November 2012 and March 2014 during an IRB approved clinical trial. Thirteen out of 18 patients remained unrevised at a minimum of 12 months; the results of radiographic and histological analysis of four revisions are presented.

The investigational device (Figure 1) was developed as a joint preserving treatment for AVN with a clinical grade of IIC or less according to the ARCO grading system2.

The device consisted of a braided spherical Nitinol cage with a Titanium / Nitinol orientation feature. It was implanted using fluoroscopic navigation into a spherical cavity cut into the femoral head via an 11mm diameter access tunnel. Once deployed, the implant was filled with a lightly impacted mixture of autologous bone graft and bone marrow soaked Conduit TCP (DePuy CMW, Blackpool, UK). The implant's purpose was to provide mechanical support to the weakened subchondral surface while the bone graft mixture re-integrated with the host bone.

The retrieved femoral heads were trimmed to leave approximately 3mm of bone around the implant, dehydrated, embedded in methacrylate resin, sectioned and thinned into 50–70µm coronal slices for histological analysis. The following observations were made (Figure 2):

Case 1 (Female, age 70, ARCO IIB, revised after 2 days): The patient was revised for spontaneous sub-trochanteric fracture secondary to osteoporosis. Contact between the native bone and bone graft was observed. Marrow elements and repair tissue were visible within the pores in the graft (Figure 2a).

Case 2 (Male, age 67, ARCO IIIC, revised after 82 days): Two wires were broken but retained within the braided structure. A radiolucent gap caused by the presence of fibrous tissue between the graft mixture and native bone was evident suggesting that the implant was unable to prevent progression in this case.

Case 3 (Female, age 70, ARCO IIC, revised after 482 days): The cavity penetrated the subchondral surface; at revision the implant was found to have breached the articular cartilage. There was partial separation of the proximal osteonecrotic fragment and no evidence of graft revascularisation or remodelling within the implant.

Case 4 (Male, age 42, ARCO IIC, revised after 469 days): There was no indication of bone graft re-integration. Collapse of the necrotic bone and deformation of the implant was diagnosed from 1 year follow-up x-rays.

Conclusion

This treatment has preserved the joints of fourteen patients. Of the four revised, two patients had clinical grades or bone quality contra-indicated for the device and three had lesions occupying more than 30% of the femoral head: Improved criteria for patient selection may be required. The device is only partially load-bearing and incapable of stabilising fractures: The radiolucent band associated with fibrous tissue formation may be an early indication of failure.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 65 - 65
1 May 2016
Campbell P Kung M Ebramzadeh E Van Der Straeten C DeSmet K
Full Access

Bone ingrowth fixation of large diameter, beaded cobalt chromium cups is generally considered to be reliable but this is typically judged radiographically. To date, implant retrieval data of attached bone has been limited. This study evaluated correlations between the pre-revision radiographic appearance and the measured amount of bone attachment on one design of porous coated cup.

Methods

Twenty-six monoblock, CoCr Birmingham Hip Resurfacing (BHR, Smith and Nephew, TN, USA) cups with macroscopic beads and hydroxyapatite coating were studied. Seventeen were revised for acetabular malposition with the remainder revised for femoral loosening (4), pain (1), infection (1), dislocation (1) or lysis (2). Median time to revision was 35 months (10 – 70 months). Ten patients were female; the median age of all patients was 54 years. The pre-revision radiographs were visually ranked for cup-bone integration as follows: 0 = none, 1 = < 50%, 2 = 50 – 75%, 3 = 76 – 95%, 4 = > 96% integration. Rankings were made for the superior and inferior aspects, without knowledge of the appearance of bone on the retrievals. The revised cups were photographed at an angle so the dome and the cup periphery were visualized. The area of bone in four equal segments in each of the superior and inferior aspects was measured with image analysis software. A probe was used to differentiate bone from soft tissue. Only bone that covered the beads was counted. Correlation coefficients were calculated for the radiographic and image analysis data.

Results

Radiographically, most cups were assessed as having more than 50% of bone attachment and 7 cups were ranked as having almost total integration with bone. Only 2 cups were assessed radiographically as fully loose. Measured total bone attachment ranged from none to 55%. Superior and inferior percent ingrowth were highly correlated (corr=0.68, p<0.001) but there was no correlation between percent bone and x-ray rank (inferior corr=0.01, p=0.96; superior corr=0.23, p=0.26). There was no correlation between cup malpositioning as a reason for revision and x-ray integration ranking (superior p=0.34; inferior p=0.80).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 64 - 64
1 May 2016
Campbell P Nguyen M Priestley E
Full Access

The histopathology of periprosthetic tissues has been important to understanding the relationship between wear debris and arthroplasty outcome. In a landmark 1977paper, Willert and Semlitsch (1) used a semiquantitative rating to show that tissue reactions largely reflected the extent of particulate debris. Notably, small amounts of debris, including metal, could be eliminated without “overstraining the tissues” but excess debris led to deleterious changes. Currently, a plethora of terms is used to describe tissues from metal-on-metal (M-M) hips and corroded modular connections. We reviewed the evaluation and reporting of local tissue reactions over time, and asked if a dose response has been found between metal and tissue features, and how the use of more standardized terms and quantitative methodologies could reduce the current confusion in terminology.

Methods

The PubMed database was searchedbetween 2000 and 2015 for papers using “metal sensitivity /allergy /hypersensitivity, Adverse Local Tissue Reaction (ALTR): osteolysis, metallosis, lymphocytic infiltration, Aseptic Lymphocytic Vasculitis-Associated Lesions (ALVAL), Adverse Reaction to Metal Debris (ARMD) or pseudotumor/ pseudotumour” as well as metal-on-metal / metal-metal AND hip arthroplasty/replacement. Reports lacking soft tissue histological analysis were excluded.

Results

131 articles describing M-M tissue histology were found. In earlier studies, the terms metal sensitivity / hypersensitivity /allergy implied or stated the potential for a Type IV delayed type hypersensitivity response as a reason for revision. More recently those terms have largely been replaced by broader terms such as ALTR, ALVAL and ARMD. ALVAL and metal hypersensitivity were often used interchangeably, both as failure modes and histological findings. Several histology scoring systems have been published but were only used in a limited number of studies. Correlations of histological features with metal levels or component wear were inconclusive, typically because of a high degree of variability. Interestingly, there were very few descriptions that concluded that the observed reactions were benign / normal or anticipated i.e. regardless of the histological features, extent of debris or failure mode, the histology was interpreted as showing an adverse reaction.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_6 | Pages 5 - 5
1 Feb 2016
Beneciuk J Hill J Campbell P George S Afolabi E Dunn K Foster N
Full Access

Purpose and Background:

To identify treatment effect modifiers within the STarT Back Trial which demonstrated prognostic stratified care was effective in comparison to standard care for patients with low back pain.

Methods:

Secondary analysis of the STarT Back Trial using 688 patients with available 4-month follow-up data. Disability (baseline and 4 months) was assessed using the Roland Morris Disability Questionnaire (RMDQ) using continuous and dichotomized (>7) outcome scores. Potential treatment effect modifiers were evaluated with group x predictor interaction terms using linear and logistic regression models. Modifiers included: age, gender, education, socio-economic status (SES), employment status, work satisfaction, episode duration, general health (SF-12), number of pain medications, and treatment expectations.