header advert
Results 1 - 50 of 2222
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 24 - 24
1 Jul 2022
Spolton-Dean C Burden E East J Toms A Bhamber N Waterson B
Full Access

Abstract

Introduction

OtisMed Shape Match ® patient specific implant cutting jigs were designed to place TKA in kinematic alignment (KA) rather than traditional mechanical alignment (MA). This product was withdrawn from the market in 2013.

It has been hypothesised that KA might lead to early implant failure. Initial evidence has not supported this.

We present 10 year outcome data for the largest single centre cohort to date.

Methodology

Between 2010 and 2013, 127 Shape Match® TKAs were implanted in 119 individuals.

Retrospective review of long leg post-operative radiographs assessed femoral mechanical anatomical angle (FMA), tibial mechanical angle (TMA), hip-knee-ankle angle (HKA), posterior tibial slope (PTS) and femoral component flexion.

Oxford Knee Scores (OKS), revision and further surgery rates were reviewed.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2016
Goto T
Full Access

Objective. We performed total knee arthroplasty (TKA) without patella resurfacing in patients with osteoarthritis (OA) of the knee. The purpose of the present study was to evaluate the clinical results and the appropriateness TKA without patella resurfacing. Methods. A total of 61 patients (61 affected knees) who had undergone a Low Contact Stress mobile − bearing knee arthroplasty (LCS− TKA) (Depuy, Warsaw, IN. USA) 10 years or more before the present study were enrolled. The LCS− TKAs did not include patella resurfacing. The patients' mean age was 77.7 ± 6.1 years (range: 59−94 years). The mean follow-up period was 121 ± 2.4 months (range: 120−129 months). The clinical evaluation used the scoring system for OA of the knees issued by the Japanese Orthopaedic Association (JOA score). We defined patellofemoral (PF) pain, crepitation, patellar clunk syndrome, spin-out, and reoperation as complications. We also used X-Ray imaging to measure the component angle, patella height, lateral shift ratio, tilting angle, femorotibial angle, posterior condylar offset and joint line, and evaluated the localization of sclerotic changes in the patella. All of the LCS− TKAs were performed by one surgeon using the midvastus approach. During the operation, the osteophyte around the patella was resected, and the osteophyte on the articular surface was shaped using a bone saw. For statistical analysis we performed Mann-Whitney's U test and adopted a significance level of P<5%. Results. The average JOA score improved significantly from 46.2 ± 10.4 before the LCS− TKA to 82.6 ± 6.1 after the LCS− TKAs (P = 0.0002). No cases of patellar clunk syndrome or spin-out. occurred. Revision surgery was performed for two cases, one involved an infection, and the other involved a patella fracture. Postoperative PF pain was found in 6 patients (6 affected knees) at the final evaluation. However, in these patients, the pain was less severe than it had been preoperatively, and revision surgery for PF pain was needed or performed. The postoperative radiological evaluation was favorable on the whole. The localization of sclerotic changes in the patella on X-ray were in 32 cases around tip of the patella, on the other no remarkable change were in 29 cases. Conclusion. The clinical and radiological evaluations of the patella non−resurfacing mobile bearing total knee arthroplasty was favorable overall. Treatment of the patella in total knee arthroplasty remains controversial. We suggest that the patella in LCS−TKAs does not always need to be resurfaced


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 9 - 9
1 Nov 2016
Khan M Faulkner A Macinnes A Gwozdziewicz L Sehgal R Haughton B Misra A
Full Access

Peri-prosthetic wound infections can complicate total knee arthroplasty (TKA) in 1–1.5% of cases and may require the input of a combined orthopaedic and plastic surgery team. Failure of optimal management can result in periprosthetic joint infection, arthrodesis or in severe cases limb amputation. A retrospective 11-year review of TKA patients was undertaken in a single unit. Data was collected on a proforma and patient demographics were identified by case note analysis. Incidence of periprosthetic wound infections was recorded. A protocol to standardise treatment was subsequently developed following multidisciplinary input. 56 patients over 11 years developed periprosthetic wound infection. 33 patients were available for analysis. The male:female ratio 1:0.7 with a mean age of 70 years (range: 32–88 years). 5 (15%) developed superficial infections, 4 (12%) patients developed cellulitis requiring antibiotics, 14 (42%) with superficial wound dehiscence and 2 (6%) required washout of the prosthesis with long-term antibiotic therapy. 4 (12%) were managed without plastics involvement, one leading to arthrodesis and 4 (12%) had plastic surgical input, with one leading to arthrodesis. The mean time before plastic surgical review after initial suspicion of infection was 13 weeks. The management of periprosthetic wound infections following TKA are variable and can require a multidiscplinary ortho-plastic approach. Early plastic surgical involvement in specific cases may improve outcome. Our proposed management protocol would facilitate in standardising the management of these complex patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 64 - 64
1 Feb 2017
Chapman R Kokko M Goodchild G Roche M Van Citters D
Full Access

Introduction. For nearly 58% of total knee arthroplasty (TKA) revisions, the reason for revision is exacerbated by component malalignment. Proper TKA component alignment is critical to functional outcomes/device longevity. Several methods exist for orthopedic surgeons to validate their cuts, however, each has its limitations. This study developed/validated an accurate, low-cost, easy to implement first-principles method for calculating 2D (sagittal/frontal plane) tibial tray orientation using a triaxial gyroscope rigidly affixed to the tibial plateau of a simulated leg jig and validated 2D tibial tray orientation in a human cadaveric model. Methods. An initial simulation assessed error in the sagittal/frontal planes associated with all geometric assumptions over a range of positions (±10°, ±10°, and −3°/0°/+3° in the sagittal, frontal, and transverse planes, respectively). Benchtop experiments (total positions - TP, clinically relevant repeated measures - RM, novice user - NU) were completed using a triaxial gyroscope rigidly affixed to and aligned with the tibial tray of the fully adjustable leg-simulation jig. Finally, two human cadaveric experiments were completed. A similar triaxial gyroscope was mounted to the tibial tray of a fresh frozen human cadaver to validate sagittal and frontal plane tibial tray orientation. In cadaveric experiment one, three unique frontal plane shims were utilized to measure changes in frontal plane angle. In cadaveric experiment two, measurements using the proprosed gyroscopic method were compared with computer navigation at a series of positions. For all experiments, one rotation of the leg was completed and gyroscopic data was processed through a custom analysis algorithm. Results. Mathematical simulations showed that over the range of tested orientations, error from our geometric assumptions would be less than 1° and 0.2° in the sagittal and frontal planes, respectively. Results of all bench-top experiments are shown in Figure 1. The average angular error during the TP experiment (black bars) was 1.09°±0.80° and 0.60°±0.46° in the sagittal/frontal planes. The average angular error during the RM experiment (white bars) in the sagittal/frontal planes was 0.27°±0.25° and 0.30°±0.23°. The average angular error from the NU experiment (grey bars) in the sagittal/frontal planes was 1.50°±1.57° and 0.82°±0.77°. During cadaveric experiment one (Figure 2), computed frontal plane angles were 2.83°±0.98°, −1.67°±1.99°, and −4.33°±0.53° after placing distinct 2° lateral, 2° medial, and 4° medial shims. Finally, the average angular error from cadaveric experiment two (Figure 3) over all positions was 1.73°±1.12° and 1.56°±1.45° in the sagittal and frontal planes, respectively. Discussion. Despite the high frequency of TKA procedures, a significant number fail and need to be revised for improper component alignment. This study showed through a first-principles approach that surgeons can assess 2D orientation of the tibial component intraoperatively with 1° of accuracy with a single triaxial gyroscope rigidly affixed to the tibial plateau. Moreover, this study showed through the use of a cadaveric model that surgeons could assess 2D alignment of the tibial component with a gyroscope rigidly affixed to the tibial plateau. To our knowledge, this is first method to offer true 2D tibial tray orientation assessment using only a single triaxial gyroscope


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 135 - 135
1 Jul 2002
Hooper G Armour P Scott J
Full Access

Aim: To compare the function in two groups of high demand patients with a total knee arthroplasty (TKA) – one group using a posterior cruciate sacrificing (PCS) prosthesis and the other a posterior cruciate retaining (PCR) prosthesis of similar design. Method: Patients were eligible for the study if they were greater than two years from surgery, less than 65 years of age and without other co-existing morbidity to significantly decrease their physical activities. Group A underwent surgery by one surgeon who routinely retained the posterior cruciate ligament whereas Group B underwent surgery by one surgeon who routinely sacrificed the PCL. A mobile bearing TKA of similar design was used in each group. All patients were selected and assessed by an independent assessor using a questionnaire developed specifically to assess higher levels of activity not usually assessed by other knee scores. Results: Group A (28 TKA in 20 patients) were matched with Group B (25 TKA in 19 patients) for age, length of follow-up and range of motion. The gross activity score was 3.36 in Group A compared with 3.12 in Group B. The combined walking, running and stair climbing score was significantly better in Group A (7.68 compared to 6.64 in Group B). Group B perceived their TKA was closer to a normal knee (2.00 compared to 2.32) with decreased anterior knee pain. Conclusions: Retaining the PCL in TKA results in better function without significant complications


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 29 - 29
1 Feb 2017
Ishida K Shibanuma N Toda A Kodato K Inokuchi T Matsumoto T Takayama K Kuroda R Kurosaka M
Full Access

PURPOSE. Total knee arthroplasty (TKA) is a successful technique for treating painful osteoarthritic knees. However, the patients' satisfaction is not still comparable with total hip arthroplasty. Basically, the conditions with operated joints were anterior cruciate ligament (ACL) deficient knees, thus, the abnormal kinematics is one of the main reason for the patients' incomplete satisfaction. Bi-cruciate stabilized (BCS) TKA was established to reproduce both ACL and posterior cruciate ligament (PCL) function and expected to improve the abnormal kinematics. However, there were few reports to evaluate intraoperative kinematics in BCS TKA using navigation system. Hence, the aim in this study is to reveal the intraoperative kinematics in BCS TKA and compare the kinematics with conventional posterior stabilized (PS) TKA. Materials and Methods. Twenty five consecutive subjects (24 women, 1 men; average age, 77 years; age range, 58–85 years) with varus osteoarthritis undergoing navigated BCS TKA (Journey II, Smith&Nephew) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum medial soft tissue release, ACL and PCL resection, and osteophyte removal. Then, kinematics including tibiofemoral rotational angles from maximum extension to maximum flexion were recorded. The measurements were performed again after implantation. We compared the kinematics with the kinematics of paired matched fifty subjects who underwent conventional posterior stabilized (PS) TKA (25 subjects with Triathlon, Stryker; 25 subjects with PERSONA, ZimmerBiomet) using navigation statistically. Results. Preoperative tibiofemoral rotational kinematics were almost the same between the three implants groups. Kinematics at post-implantation found that tibia was significantly internally rotated compared to the kinematics at registration in all three implants at maximum extension position (p<0.05), however the tibial rotational position with BCS TKA was significantly externally rotated at maximum extension position, compared to the other two implant position (p<0.05). The tibial rotational position with Triathlon PS TKA was externally rotated at 60 degrees of flexion compared to the other two implant position, however the results were not statistically significant. Discussion and Conclusion. Previous study found that PCL resection changed tibial rotational position and the amount of tibial internal rotation, affecting postoperative maximum flexion angles. This study found that BCS TKA can reduce the amount of rotational changes, compared to conventional PS TKA. Further studies are needed to investigate the kinematic changes in BCS TKA affect the postoperative clinical outcomes


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_13 | Pages 40 - 40
1 Sep 2014
Hardcastle P de Jongh H du Preez G
Full Access

Purpose Of Study. The in vivo evaluation of patellofemoral contact pressures in a posterior stabilized compared to posterior cruciate sacrificing total knee arthroplasty (TKA). Methods. A prospective descriptive non randomized study was performed on 8 patients. A standard approach to a TKA was performed using a balanced gap technique, while the patella was prepared for a resurfacing. The trial components for the posterior stabilized (PS) TKA where inserted including the gas sterilized pressure transducer (a patella button). Soft tissue was approximated and the knee was taken through full range of movement. Patellofemoral pressure was measured and captured continuously through the full range of movement. The posterior cruciate sacrificing (CS) components were inserted into the same patient and the procedure repeated. In addition, anterior translation of the tibia relative to the femur was measured at 90 degrees. The transducer was removed and final components, including a patella resurfacing were inserted. Results. Significantly lower patella femoral pressures were found for PS TKA compared to CS TKA in full flexion [129.0 ± 21.7 N vs. 109.9 ± 32.1 (p = 0.038173)]. The change in patellofemoral pressure between flexion and extension was significantly lower in PS TKA compared to CS TKA [109.0 ± 21.6 N vs. 90.5 ± 32.0 (p = 0.0037690)]. In addition mean anterior translation at 90° flexion in the CS TKA (6.4 ± 3.2 mm) was significantly less than in PS TKA (17.0 ± 2.6) (p = 0.000072). Conclusion. Significantly lower patellofemoral pressures were found in full flexion with PS TKA compared to CS TKA. The change in patellofemoral pressure in a PS TKA compared to CS TKA was also significantly lower. This study provides possible clinical data when considering patella resurfacing. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 313 - 313
1 May 2009
Pioch M Reumann M Herrmann P Wentzensen A Wagner C Heppert V
Full Access

In selected patients, knee arthrodesis is a well-recognised salvage procedure after infected total knee arthroplasty (TKA). Several procedures of arthrodesis have been introduced and should be adapted to the individual situation of the patient. In our center we regularly treat elderly patients after multiple revision operations; in 36% defects of the bone, soft tissue or the extensor mechanisms are present. In these cases we prefer arthrodesis to reimplantation. Because of the high rate of non-unions when using an external fixator, we perform arthrodesis by use of an intramedullary rod system. The objective of this study was to compare the results of different rod systems for knee arthrodesis after TKA infection. We reviewed the results of 3 rod systems in 34 patients: cementless system (Brehm; n=9), cement rod usually used in tumor patients (Mutars; n=7) and a regular cement rod system (Link; n=18). In the group of cementless rods we had to explantate 3 rods because of a relapse of the infection. This is most propably due to the technical design of the system: in poor soft tissue situation the tissue is compressed by the voluminary docking part which causes continuous necrosis. This problem can be avoided by an early tissue flap. Of the Mutars rod system we had to explantate 2 systems; one because of an infection, the other one due to telescoping, which can be avoided by use of a longer stem with the option to interlock. In the group of the Links system no revision was necessary. In our opinion, arthrodesis of the knee using a rod system is a satisfactory salvage procedure following an infected TKA, especially in elderly patients, and can provide reliable, painless extremity and satisfactory quality of life


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 29 - 29
1 Jan 2003
Khaw F Kirk L Gregg P
Full Access

Cementless fixation for total knee arthroplasty (TKA) has been proposed as an alternative to cemented for several reasons, of which the most important is the possibility of increased survival. The purpose of this study was to compare the ten-year survival of TKA in a unique prospective randomised trial of cemented versus cementless fixation. A consecutive series of patients was randomised to undergo either cemented or cementless Press-Fit Condylar (PFC®) TKA. There were 219 patients (277 TKA) in the cemented group and 177 (224 TKA) in the cementless group. There were no significant differences in age, gender or diagnosis between the two groups. A single surgeon (PJG) performed or directly supervised all operations. The prosthesis used in all cases was the posterior-cruciate-retaining PFC® knee replacement system. Independent clinical review was performed at six months, annually until five years, and finally at ten years after surgery. Using revision surgery as the end-point, logrank analysis was used to compare the ten-year survival of the two groups. The mean interval of follow-up was 6.3 years (range, 2.0–11.7). At the last review, 104 patients (138 TKA) had died, without need for revision. All patients were traced and there was no loss to follow-up. In the cemented group, seven arthroplasties were revised; five for infection and two for exchange of polyethylene inserts. Ten-year survival was 96.5% (95% CI, 90.9–98.7%). In the cementless group, six arthroplasties were revised; three for aseptic loosening, one for infection, one for instability and one resizing for anterior knee pain. The ten-year survival was 96.6% (95% CI, 89.6–98.9%). There was no significant difference in the survival of the two groups. The long-term survival of cementless PFC® TKA is not significantly different from their cemented counterparts. The use of less expensive cemented implants, therefore, can make a significant impact on health resource planning


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 67 - 67
4 Apr 2023
Emmerzaal J De Brabandere A van der Straaten R Bellemans J De Baets L Davis J Jonkers I Timmermans A Vanwanseele B
Full Access

In a clinical setting, there is a need for simple gait kinematic measurements to facilitate objective unobtrusive patient monitoring. The objective of this study is to determine if a learned classification model's output can be used to monitor a person's recovery status post-TKA.

The gait kinematics of 20 asymptomatic and 17 people with TKA were measured using a full-body Xsens model1. The experimental group was measured at 6 weeks, 3, 6, and 12 months post-surgery. Joint angles of the ankle, knee, hip, and spine per stride (10 strides) were extracted from the Xsens software (MVN Awinda studio 4.4)1.

Statistical features for each subject at each evaluation moment were derived from the kinematic time-series data. We normalised the features using standard scaling2. We trained a logistic regression (LR) model using L1-regularisation on the 6 weeks post-surgery data2–4.

After training, we applied the trained LR- model to the normalised features computed for the subsequent timepoints. The model returns a score between 0 (100% confident the person is an asymptomatic control) and 1 (100% confident this person is a patient). The decision boundary is set at 0.5.

The classification accuracy of our LR-model was 94.58%. Our population's probability of belonging to the patient class decreases over time. At 12 months post-TKA, 38% of our patients were classified as asymptomatic.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 55 - 55
1 Dec 2022
Nowak L Campbell D Schemitsch EH
Full Access

To describe the longitudinal trends in patients with obesity and Metabolic Syndrome (MetS) undergoing TKA and the associated impact on complications and lengths of hospital stay.

We identified patients who underwent primary TKA between 2006 – 2017 within the American College of Surgeons National Surgical Quality Improvement Program (NSQIP) database. We recorded patient demographics, length of stay (LOS), and 30-day major and minor complications. We labelled those with an obese Body Mass Index (BMI ≥ 30), hypertension, and diabetes as having MetS. We evaluated mean BMI, LOS, and 30-day complication rates in all patients, obese patients, and those with MetS from 2006-2017. We used multivariable regression to evaluate the trends in BMI, complications, and LOS over time in all patients and those with MetS, and the effect of BMI and MetS on complication rates and LOS, stratified by year.

270,846 patients underwent primary TKA at hospitals participating in the NSQIP database. 63.71% of patients were obese (n = 172,333), 15.21% were morbidly obese (n = 41,130), and 12.37% met criteria for MetS (n = 33,470). Mean BMI in TKA patients increased at a rate of 0.03 per year (0.02-0.05; p < 0 .0001). Despite this, the rate of adverse events in obese patients decreased: major complications by an odds ratio (OR) of 0.94 (0.93-0.96; p < 0 .0001) and minor complications by 0.94 (0.93-0.95; p < 0 .001). LOS also decreased over time at an average rate of −0.058 days per year (-0.059 to −0.057; p < 0 .0001). The proportion of patients with MetS did not increase, however similar improvements in major complications (OR 0.94 [0.91-0.97] p < 0 .0001), minor complications (OR 0.97 [0.94-1.00]; p < 0 .0330), and LOS (mean −0.055 [-0.056 to −0.054] p < 0 .0001) were found. In morbidly obese patients (BMI ≥ 40), there was a decreased proportion per year (OR 0.989 [0.98-0.994] p < 0 .0001). Factors specifically associated with major complications in obese patients included COPD (OR 1.75 [1.55-2.00] p < 0.0001) and diabetes (OR 1.10 [1.02-1.1] p = 0.017). Hypertension (OR 1.12 [1.03-1.21] p = 0.0079) was associated with minor complications. Similarly, in patients with MetS, major complications were associated with COPD (OR 1.72 [1.35-2.18] p < 0.0001). Neuraxial anesthesia was associated with a lower risk for major complications in the obese cohort (OR 0.87 [0.81-0.92] p < 0.0001). BMI ≥ 40 was associated with a greater risk for minor complications (OR 1.37 [1.26-1.50] p < 0.0001), major complications (1.11 [1.02-1.21] p = 0.015), and increased LOS (+0.08 days [0.07-0.09] p < 0.0001).

Mean BMI in patients undergoing primary TKA increased from 2006 - 2017. MetS comorbidities such as diabetes and hypertension elevated the risk for complications in obese patients. COPD contributed to higher rates of major complications. The obesity-specific risk reduction with spinal anesthesia suggests an improved post-anesthetic clinical course in obese patients with pre-existing pulmonary pathology. Encouragingly, the overall rates of complications and LOS in patients with obesity and MetS exhibited a longitudinal decline. This finding may be related to the decreased proportion of patients with BMI ≥ 40 treated over the same period, possibly the result of quality improvement initiatives aimed at delaying high-risk surgery in morbidly obese patients until healthy weight loss is achieved. These findings may also reflect increased awareness and improved management of these patients and their elevated risk profiles.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 227 - 227
1 Mar 2004
Fuiko R Kotten B Zettl R Ritschl P
Full Access

Aims: Kinematic and pointing procedures, are used for non-image based navigated implantation of TKA. Pointing procedures require exact knowledge about the landmarks. In this anatomical study, landmarks are defined and repeatedly referenced. The precision and the reproducibility are evaluated, by means of inter- and intra- observer study. Using the landmarks, the axes of the femur and tibia are calculated. Methods: The specific landmarks of 30 femur and 27 tibia specimens, were palpated by 3 surgeons and digitised by means of a photogrammetric system, as used intra-operatively. The recorded data are evaluated. Results: The specific landmarks can be referenced with great precision. The vectors that influence the implant position, show femoral a mean inter-observer deviation of 0,9mm and 1,0mm tibial. The repeating accuracy of every single observer was 1,5mm femoral and 1,0mm tibial. The calculated long axes at the femur and tibia, thus reach a precision of 0.1° (min-max:0°–0,9°) at the femur and 0,2° (min-max:0°–1,1°) at the tibia. The short axes at the distal femur and at the proximal tibia, exhibit an average deviation of 0,7° to 1,9° (min-max: 0°–11,3°). Conclusion: Long axes (mechanical axes) can be determined exactly, the precision of the short axes (rotational axes) is unsatisfactory, although palpation of landmarks were accurate. Therefore, palpation of more than one rotational axis at the femur and the tibia, is mandatory and should be visualized on the monitor during the operation.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 93 - 93
1 May 2011
Bercovy M Beldame J Lefebvre B
Full Access

Which parameters are related with a forgotten knee after TKA?

The operated knee was said forgotten when it was similar to the normal controlateral knee in all situations.

When a restriction existed, the knee was considered as not forgotten.

470 patients operated with a stabilised mobile bearing knee were examined with a minimal follow up of 5 years and answered to this question.

4 groups of parameters: patient, prosthesis, surgery and post operative care were compared to the binary answer to the forgotten knee question.

48% of the patients had a forgotten knee one year after the TKA;

The following factors had a significant negative correlation with the forgotten knee:

low SF12 psychological profile; Patellofemoral dysplasic arthritis (p = 0,01);

femoral oversizing (p=0,001);

tight extension gap, femoral lengthening, tourniquet time; overcorrection superior to 2°(p = 0,02).

We found no correlation between the following factors and the forgotten knees:

gender, BMI, approach, cemented or not, patellar resurfacing; preoperative Oxford and Knee Society knee scores;

The forgotten knee is a simple objective clinical item because the answer to the question is binary and does not accept any unprecision. It is highly correlated with surgical scores and patients expectation scores (p = 0,0001).

The forgotten knee is a painless and asymptomatic knee identical to a normal knee.

Surgical factors have the highest infiuence on this parameter compared to patient or prosthetic related factors.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 556 - 556
1 Dec 2013
Tei K Matsumoto T Shibanuma N Kurosaka M Kuroda R
Full Access

Introduction. Recently, tibial insert design of cruciate-substituting (CS) polyethylene insert is employed. However, in vivo kinematics of using CS polyethylene insert is still unclear. In this study, it is hypothesized that CS polyethylene insert leads to stability of femolo-tibial joint as well as posterior-stabilized polyethylene insert, even if posterior cruciate ligament (PCL) is sacrificed after total knee arthroplasty (TKA). The purpose of this study is an investigation of in vivo kinematics of three different tibial insert designs using computer assisted navigation system intra-operatively in TKA. Materials and Methods. Sixty-four consecutive patients who had knees of osteoarthritis with varus deformity were investigated in this study. All TKAs (Triathlon, Stryker, New Jersey, USA) were performed using computer assisted navigation system. During surgery, three different designs of polyethylene tibial trial inserts (PS, CS, and cruciate-retaining (CR) polyethylene insert) were inserted respectively after implantation of femoral and tibial components. The kinematic parameters of the soft-tissue balance were obtained by interpreting kinematics curve, which display bicompartmental gaps throughout the range of motion (ROM) after implantation of each trial insert (Figure. 1). During record of kinematics, the surgeon gently lifted the experimental thigh three times, flexing the hip and knee. Deviation of these three values in each ROM was calculated in each tibial insert in each patient for descriptive analysis. Results. Regarding to values of compartmental gaps, there are no significance between three inserts in both medial and lateral compartments (Figure 2a, b). On medial compartmental gaps, the values of deviations were significantly higher in CR insert than both of PS and CS insert in ROM of over 45 degrees in extension (Fig 3a). In addition, concerning lateral compartmental gaps, the values of deviations were significantly higher in CS insert than both PS and CS insert in all ROM (Fig 3b). Furthermore, there was no significance between PS and CS insert in overall range of motion in both medial and lateral compartmental gaps (Fig 3a, b). Discussion. These results demonstrated that CS polyethylene insert has a stability of femoro-tibial joint nearly as well as PS polyethylene insert. While PS insert may leads to surface damage on open box and has necessity of cutting more bone of femur, some problems involving management of PCL are enumerated in CR inserts. The main design feature of Triathlon CS insert is single radius and rotary arc, in addition, the posterior lip is same as that of Triathlon CR, which can be the factor to avoid paradoxical anterior movement and to permit internal and external rotation between femoral and tibial component. Due to the design features and benefits, there is a high possibility that CS insert can lead same ROM as PS insert, although PS design can produce more ROM than the other type of insert type. Based on these backgrounds, it is suggested that CS insert may have an additional choice in TKA with some advantages especially in concerning of high activity patients like middle aged patients


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 50 - 50
1 Jun 2012
Dinges H
Full Access

Today TKA belongs to a standard care in orthopaedics and traumatology. The number of the annual implantations has clearly increased during the last years and also in the future an increasing rate to be expected.

Also the number of Revision TKA and the treatment of complicated pathologies in the primary care will increase in the same way.

Therefore the requirements of the surgeon rised as well as a suitable and accurate systems will be needed. Beside revision cases, traumatic-, post-traumatic- and RA-patients demonstrate partly distinctive bone and ligamentous pathologies.

Beside the primary implant components and instrumentation-systems, modern knee systems must include also modular revision systems compatible with the primary systems to be able to carry out complicated primary as well as light to moderately severe recision cases. Besides, also the possibility should be able to change within the system (with constant bone-cuttings) on higher degrees of the constrain.

With the TC-Primary and TC-Revision system fulfils the above mentioned criteria so that nearly every situation can be handled.

We present our experience using this system in cases of revisions, traumatic, post-traumatic and RA-cases The handling of bone and ligamentous defects will be demonstrated. In particular the possibility the use of the TC-Revision also in primary TKA as P a so named “extension primary system” will be emphasized.

By the Modulary and compatibility of the TC-Primary and TC-Revision systems, the use of Wedges and Stems as well as the possibility of the different degrees of the constrain a knee family permits us to treat complicated primary as well as mild to moderate revision cases.


Introduction

Schatzker V & VI tibial plateau fractures are serious life-changing injuries often resulting in significant complications including post-traumatic arthritis. Reported incidence of secondary TKA following ORIF of all tibial plateau fractures is 7.3% and 13% for Schatzker V & VI tibial. This study reports a 15-year single centre experience of CEF of Schatzker V & VI fractures including PROMs and incidence of secondary TKA. This study was approved by the local Institutional board.

Materials & Methods

All patients from 2007 – 2022 with Schatzker V or VI fractures treated with CEF were identified from a departmental limb reconstruction registry and included in this retrospective study. Patients’ demographics were collected from electronic institutional patient system. Further data was collected for secondary intervention, adverse events, and alignment at discharge. All deceased patients at the time of the study were excluded.

Each participant completed a questionnaire about secondary intervention, EQ-5D-3L and Oxford Knee Score (OKS).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 100 - 100
1 Jan 2017
Navruzov T Rivière C Van Der Straeten C Harris S Cobb J Auvinet E Aframian A Iranpour F
Full Access

The accurate positioning of the total knee arthroplasty affects the survival of the implants(1). Alignment of the femoral component in relation to the native knee is best determined using pre- and post-operative 3D-CT reconstruction(2). Currently, the scans are visualised on separate displays. There is a high inter- and intra-observer variability in measurements of implant rotation and translation(3). Correct alignment is required to allow a direct comparison of the pre- and post-operative surfaces. This is prevented by the presence of the prostheses, the bone shape alteration around the implant, associated metal artefacts, and possibly a segmentation noise.

The aim is to create a novel method to automatically register pre- and post-operative femora for the direct comparison of the implant and the native bone.

The concept is to use post-operative femoral shaft segments free of metal noise and of surgical alteration for alignment with the pre-operative scan. It involves three steps. Firstly, using principal component analysis, the femoral shafts are re-oriented to match the X axis. Secondly, variants of the post-operative scan are created by subtracting 1mm increments from the distal femoral end. Thirdly, an iterative closest point algorithm is applied to align the variants with the pre-operative scan.

For exploratory validation, this algorithm was applied to a mesh representing the distal half of a 3D scanned femur. The mesh of a prosthesis was blended with the femur to create a post-operative model. To simulate a realistic environment, segmentation and metal artefact noise were added. For segmentation noise, each femoral vertex was translated randomly within +−1mm,+−2mm,+−3mm along its normal vector. To create metal artefact random noise was added within 50 mm of the implant points in the planes orthogonal to the shaft. The alignment error was considered as the average distance between corresponding points which are identical in pre- and post-operative femora.

These preliminary results obtained within a simulated environment show that by using only the native parts of the femur, the algorithm was able to automatically register the pre- and post-operative scans even in presence of the implant. Its application will allow visualisation of the scans on the same display for the direct comparison of the perioperative scans.

This method requires further validation with more realistic noise models and with patient data. Future studies will have to determine if correct alignment has any effect on inter- and intra-observer variability.


Introduction: The success of total knee arthroplasty (TKA) is dependent on many factors. Postoperative extremity and component alignment are important determinants of outcome and longevity and malalignment results in higher failure rates. Computer-assisted (CAS) navigation devices were developed to improve implant positioning but their use increases the complexity of the surgery. The aim of this study is to assess the radiological outcome of conventional techniques versus CAS for TKA performed by an expert and other group performed by a beginner in CAS. Methods: 90 patients patients with knee arthritis were prospective randomized into 3 groups: CAS performed by an expert, CAS performed during the learning curve and conventional technique (manual instrumentation) performed by an expert. Preoperative and postoperative clinical examinations were performed at four weeks, six months, and one year by an independent physician who was blinded to the surgical technique. Preoperative and postoperative radiographic measurements of the anterior-posterior mechanical axis and the sagittal tibial and femoral axes were evaluated by an observer who was blinded to the surgical technique. The Knee Society Scoring System was used to asses clinical and functional outcomes. All variables were analysed for differences between the groups either by Student’s t-test or the Mann-Whitney U test. Results: There was no differences in implant positioning between the CAS groups. The mechanical axis of the leg was significantly better in the two CAS groups (96%, within +/−3° varus/valgus) compared with the conventional Group (78%, within +/− 3° varus/valgus). The frontal and sagittal alignment of the femoral component and the frontal tibial alignment were also more precise in the CAS groups. Improvement occurred in the Knee Society scores up to one year post-operatively and was similar for the three groups. No significant difference between the groups could be found at any time point in the study, with the mean difference being 3.5 points (95% CI;18.6 to 13.6). Conclusions: We have not shown differences in the precise positioning of implants during the learning curve in computer-assisted total knee arthroplasty. Computer-assisted total knee arthroplasty gives a better correction of alignment of the leg and orientation of the components compared with the conventional technique. Potential benefits in the long-term outcome and functional improvement require further investigation


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 10 - 10
1 Dec 2013
Bandi M Scuderi G Siggelkow E Sauerberg I Benazzo F
Full Access

Summary:

Smaller increments in the antero-posterior dimensions of femoral components allows significant improvements in balancing of the knee after TKA with restoration of more normal soft-tissue stability.

Introduction:

The soft-tissue stability of the knee after TKA is often compromised by the fact that only a finite set of implantable component sizes is available to match bony anatomy. While this could be overcome with custom components, a more practical solution is a set of femoral components with smaller increments in the antero-posterior (AP) dimension. However, this results in a larger assortment of sizes of both implants and trial components. This study was performed to determine whether smaller increments in the AP sizing of knee prostheses would lead to real benefits in restoration of normal knee function and stability after TKA.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 52 - 52
1 Mar 2017
Navruzov T Riviere C Van Der Straeten C Harris S Aframian A Iranpour F Cobb J Auvinet E
Full Access

Background

The accurate positioning of the total knee arthroplasty affects the survival of the implants(1). Alignment of the femoral component in relation to the native knee is best determined using pre- and post-operative 3D-CT reconstruction(2). Currently, the scans are visualised on separate displays. There is a high inter- and intra-observer variability in measurements of implant rotation and translation(3). Correct alignment is required to allow a direct comparison of the pre- and post-operative surfaces. This is prevented by the presence of the prostheses, the bone shape alteration around the implant, associated metal artefacts, and possibly a segmentation noise.

Aim

Create a novel method to automatically register pre- and post-operative femora for the direct comparison of the implant and the native bone.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 405 - 405
1 Dec 2013
Varadarajan KM Zumbrunn T Rubash HE Malchau H Li G Muratoglu O
Full Access

Introduction:

Contemporary Posterior Cruciate Ligament (PCL) retaining TKA implants (CR) are associated with well-known kinematic deficits, such as absence of medial pivot motion, paradoxical anterior femoral sliding, and posterior femoral subluxation at full extension. The hypothesis of this study was that a biomimetic implant, reverse engineered by using healthy knee kinematics to carve the tibial articular surface, could restore normal kinematic patterns of the knee.

Methods:

Kinematics of the biomimetic CR and two contemporary CR implants (A, B) were evaluated during simulated deep knee bend and chair-sit in LifeModeler KneeSIM™ software. Anteroposterior motion of the medial and lateral femoral condyle centers was measured relative to a tibial origin. The implants were mounted on an average knee model created from magnetic resonance imaging (MRI) of 40 healthy knees. The medial and lateral collateral ligaments, posterior cruciate ligament, quadriceps mechanism, and the overall capsular tension were modeled. The soft-tissue insertions were obtained from the average knee model, and the mechanical properties were obtained from literature. In vivo knee kinematics of healthy subjects from published literature was used for reference.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 45 - 45
1 Mar 2009
Poultsides L Varitimidis S Dailiana Z Klitsaki A Theodorou E Stamatiou G Malizos K
Full Access

Introduction: TKA is usually performed under general or spinal anaesthesia (SA). Most of the patients who undergo this procedure are old and their postoperative rehabilitation could be compromised due to the adverse effects of the relevant anaesthesia. Lumbar Plexus and Sciatic nerve Block (LPSB) have been increasingly applied for intraoperative and postoperative analgesia. The aim of this study is to compare the time required for the performance of the anaesthesia technique, the quality of intraoperative anaesthesia and postoperative analgesia, the incidence of intraoperative or postoperative complications, the blood loss at the recovery room and the required intraoperative intravenous (IV) administration of fluid volume.

Material & Methods: Fifty (50) patients, mean age 70± 5years, ASA I-III were randomly divided into two groups to receive spinal anaesthesia (group A) or LPSB (group B). Patients in group A (n=25) received hyperbaric Bupi-vacaine 0.5% plus 15mcq Fentanyl through atraumatic 25g needle. Lumbar plexus and sciatic nerve block were performed with a 15cm insulated needle (Brown) and nerves were identified by a peripheral electric nerve stimulator. 30 and 15 ml of Ropivacaine (0.5%) were used for each block respectively. All patients received 0.2mg/ Kg of Midazolam and 50μg of Fentanyl IV. The success of the technique was defined as a complete sensory and motor block. All patients received postoperatively Patient-Controlled Anaesthesia (PCA) with morphine intravenously. Time to perform blockade, sensory and complete motor block, hemodynamic parameters, blood loss, IV fluid volume, postoperative analgesic requirements and satisfaction score were recorded. Results were analyzed with Chi Square test and Student’s t-test (level of significance: p< 0.05).

Results: Demographic data, operating time and hemo-dynamic parameters were similar in both groups. Three patients (group B) had insufficient blocks and were converted to general anaesthesia. Although SA is performed and accomplishes complete motor and sensory blockade faster (p< 0,05), LPSB leaded to decreased necessity of intraoperative fluid loading and blood loss at the recovery room (p< 0,05). Overall patient’s satisfaction till leaving the recovery room, Visual Analogue Score (VAS) intraoperatively, 4 and 8hours postoperatively and analgesic counts (recorded through the PCA) in the first 24hours were statistically significant between two groups, in favor of patients with LPSB.

Conclusion: PLSB is an effective alternative to spinal anesthesia taking into account basic clinical and anaesthesiological parameters intraoperatively and immediate postoperatively. Concerning postoperative pain and required administration of analgesics during the first 24hours, LPSB is more efficient compared to SA, underlining the importance of overall patient’s satisfaction during the first postoperative day.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 64 - 64
1 Mar 2013
Gavriely N
Full Access

Introduction & Aims

Mild to moderate CD after TKA is a common side-effect of an otherwise successful procedure. Despite improvement in the majority of the cases within weeks to a few months, this is a source of concern and disappointment. This analysis presents a possible mechanism for post-TKA cognitive changes.

Method

We reviewed the literature on the hemodynamic events around limb exsanguination, tourniquet placement and release during TKA. The majority of this literature is in anesthesia journals, with only a few in orthopedic journals (e.g., Berman, JBJS, 1998, 389–96). Once the data was collected, we scrutinized it for validity and in order to identify a plausible etiology that links between the TKA operating procedure and CD.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 171 - 171
1 Mar 2008
Kessler O Lacatusu E Erne OV Zandschulp C Engel C Spriggins A Bottlang M
Full Access

This study investigated the difference in proximal tibial cortical strain distribution using a fixed or mobile bearing design for TKA.

Eight fresh frozen human cadaver tibias were used. The strain magnitude and distribution on the anterior cortex of the proximal tibia during axial and rotational loading of the knee were measured with a quantitative full-field strain measurement technique (Electronic Speckle Pattern Interferometry). First, strain distributions of the intact knee were acquired. Subsequently, strain distributions after implantation of conventional and mobile bearing PCL retaining total knee implants (Scorpio®) were measured

Under each loading condition, the minimum principal strain was greater in magnitude as compared to the maximum principal strain. Under 1,500 N axial loading, the resulting minimum principal strain magnitude and orientation was nearly identical between the mobile bearing configuration(500 ± 287m;e;), and the fixed bearing configuration (500 ± 286m;e;). In response to 10° internal rotation, this strain increased to 782 ± 371m;e; and 1000± 389m;e; for the mobile and fixed tibial component, respectively. In 10° external rotation, minimal principal strain decreased to 421 ± 233m;e; for the mobile bearing, but increased to 632 ± 293m;e; for the fixed bearing. These differences between mobile and fixed bearing scenarios were highly statistically significant.

For this in-vitro study under exact controlled loading conditions the mobile bearing design induced less strain in the proximal tibia than the fixed bearing tibial component. The difference in strain levels may be of importance for bone remodeling and osseointegration.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 52 - 52
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Patients ≤ 55 years have a high primary TKA revision rate compared to patients >55 years. Guided motion knee devices are commonly used in younger patients yet outcomes remain unknown. In this sub-group analysis of a large multicenter study, 254 TKAs with a second-generation guided motion knee implant were performed between 2011–2017 in 202 patients ≤ 55 years at seven US and three European sites. Revision rates were compared with Australian Joint Registry (AOANJRR) 2017 data. Average age 49.7 (range 18–54); 56.4% females; average BMI 34 kg/m2; 67.1% obese; patellae resurfaced in 98.4%. Average follow-up 4.2 years; longest follow-up six years; 27.5% followed-up for ≥ five years. Of eight revisions: total revision (one), tibial plate replacements (three), tibial insert exchanges (four). One tibial plate revision re-revised to total revision. Revision indications were mechanical loosening (n=2), infection (n=3), peri-prosthetic fracture (n=1), and instability (n=2). The Kaplan-Meier revision estimate was 3.4% (95% C.I. 1.7% to 6.7%) at five years compared to AOANJRR rate of 6.9%. There was no differential risk by sex. The revision rate of the second-generation guided motion knee system is lower in younger patients compared to registry controls.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 51 - 51
1 Mar 2021
Harris A O'Grady C Sensiba P Vandenneucker H Huang B Cates H Christen B Hur J Marra D Malcorps J Kopjar B
Full Access

Outcomes for guided motion primary total knee arthroplasty (TKA) in obese patients are unknown. 1,684 consecutive patients underwent 2,059 primary TKAs with a second-generation guided motion implant between 2011–2017 at three European and seven US sites. Of 2,003 (97.3%) TKAs in 1,644 patients with BMI data: average age 64.5 years; 58.4% females; average BMI 32.5 kg/m2; 13.4% had BMI ≥ 40 kg/m2. Subjects with BMI ≥ 40 kg/m2 had longest length of hospital stay (LOS) at European sites; LOS similar at US sites. Subjects with BMI ≥ 40 kg/m2 (P=0.0349) had longest surgery duration. BMI ≥ 40 kg/m2 had more re-hospitalizations or post-TKA reoperations than BMI < 40 kg/m2 (12.7% and 9.2% at five-year post-TKA, P<0.0495). Surgery duration and long-term complication rates are higher in patients with BMI ≥ 40 kg/m2, but device revision risk is not elevated.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 330 - 330
1 May 2010
Rodríguez-Merchán E
Full Access

Introduction: The current gold standard for the treatment of the infected total knee arthroplasty is a two-stage revision. The purpose of this study is to present our results with two-stage revision arthroplasty in a series of 48 infected TKAs.

Materials and Methods: Over a 10-year period (1996–2005) we have performed 2140 TKAs. Of them 48 (48 patients) were infected and required a two-stage revision arthroplasty (2.2% infection rate). In 43 patients of these patients we used LCCK prostheses (Zimmer, USA) and in 5 (with severe instability) a rotating hinge prosthesis (Waldemar Link, Germany). In 26 occasions antibiotics-loaded cement (Palacos with gentamicine) was used and in 22 we used articulated spacers. The average age of patients was 67 years (range, 59–82) and the average follow-up was 5.5 years (range: 1–10). The results were assessed according to the Knee Society scores.

Results: Four knees were re-infected. Results were excellent in 28 knees, good in 13, fair in 3 and poor in 4 (the four re-infected prostheses). The four infected prostheses had been treated by static spacers. The survival rate taking as end-point removal of components for infection is 91.6% (results at average of 5.5 years).

Conclusion: Our results confirm that two-stage revision TKA is a reproducible procedure in the infected primary TKA. Also that articulated antibiotic-loaded spacers seem to be better than static spacers.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 148 - 148
1 Mar 2008
Burnett R Maloney W Barrack R Ponzar M Clohisy J
Full Access

Purpose: Problem : Infection in TKA is a devastating yet common complication. 2-stage reimplant procedures are performed in the treatment of this condition. Purpose:To evaluate the clinical, radiographic, complications, and patient satisfaction results of 2nd stage reimplantation revision TKA with the use of a TTO. Technical aspects of TTO length, fixation, bypass, and complications are reported.

Methods: From 1996–2004 our database identified 25 revision TKA (12% of 206 revision TKA) performed using a TTO. In 20/25 cases the procedure was a 2nd stage reimplant. Demographics, infecting organism, Gustillo grade, clinical, radiographic, AORI defects, complications, patient satisfaction were evaluated prospectively. All patients were followed until radiographic union of the TTO.

Results: At a mean follow up of 22 mo(range,6–84) no patients were lost to follow-up. 24 (96%)TTO’s healed - 1 requiring revision ORIF. Prior to reimplantation, patients had undergone a mean of 3.3 prior knee surgeries(range,2–8). Prior extensor mechanism procedures had been performed in 43% of knees. Methicillin resistant staphylococcus was the infecting organism in > 50% of knees. 19 knees had a static cement spacer removed at revision. Time to 2nd stage reimplant was 39 weeks(range,15–68). Poor preop range of motion and stiffness (mean arc 430 , range 10–950) improved significantly postop (mean flexion 880 p< .05). 13 (56%) knees required an adjunctive extensor procedure at the time of TTO. TTO length averaged 8.8cm(range,8–10). Screws(15 knees), 2mm cables(6), wires(4) were used for TTO fixation. Mean stem bypass of the TTO was 63mm (−20 to 100). 21 (84%) patients were satisfied with the procedure, despite 8 knees(32%) requiring further surgery. 6 (24%) TTO complications occurred; 1 escape requiring fixation. All TTO’s had healed at recent follow up.

Conclusions: TTO is a useful procedure for exposure in 2nd stage revision TKA. TTO union is predictable(96%), despite technical complications. Recurrence of infection requiring further surgery did not compromise TTO results. Prior/concurrent extensor mechanism procedures were noted frequently.

Funding : Other Education Grant

Funding Parties : Wright Medical Technologies


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 322 - 322
1 Mar 2004
Hofmann S Roth-Schiffl E Albrecht T Graf R
Full Access

Aims: To evaluate the clinical signiþcance of isolated femoral malrotation after otherwise well performed painful TKAñs. Methods: 11 painful TKAñs (5 female, 6 male, mean 61 years, range 41 to 73) with normal mechanical axis, patella tracking, stability in extension and no signs of infection or loosening were included in this prospective study. The knees were evaluated by routine clinical and radiographic examinations in combination with a standardized computer tomography (CT) to measure the rotation of the components, using the transepicondylar axis as a reference for the femur. Results: All patients had progressive persistent pain from the time of surgery which was resistant to conservative therapy. There were two groups according to the clinical symptoms: limited ßexion and medial pain at the proximal tibia (4) or ßexion > 90û with anterior knee pain during stairs descending or raising from a chair (7). Standard x-rays were normal but in the special CT all patients showed isolated internal malrotation of the femoral component mean 7û (2 to 10). 9 patients required revision surgery with correction of the malrotated femoral component. The two patients who did not want revision surgery had only minor malrotation (< 4û).Conclusions: In painful TKAñs with unknown persistent pain but limited ßexion and/or lateral instability in the ßexion gap evaluation of the femoral component rotation with a special CT should be performed.


Bone & Joint Open
Vol. 4, Issue 12 | Pages 948 - 956
15 Dec 2023
Vella-Baldacchino M Webb J Selvarajah B Chatha S Davies A Cobb JP Liddle AD

Aims. With up to 40% of patients having patellofemoral joint osteoarthritis (PFJ OA), the two arthroplasty options are to replace solely the patellofemoral joint via patellofemoral arthroplasty (PFA), or the entire knee via total knee arthroplasty (TKA). The aim of this study was to assess postoperative success of second-generation PFAs compared to TKAs for patients treated for PFJ OA using patient-reported outcome measures (PROMs) and domains deemed important by patients following a patient and public involvement meeting. Methods. MEDLINE, EMBASE via OVID, CINAHL, and EBSCO were searched from inception to January 2022. Any study addressing surgical treatment of primary patellofemoral joint OA using second generation PFA and TKA in patients aged above 18 years with follow-up data of 30 days were included. Studies relating to OA secondary to trauma were excluded. ROB-2 and ROBINS-I bias tools were used. Results. A total of nine studies were included, made up of four randomized controlled trials (domain 1) and five cohort studies (domain 2). PROMs and knee function specific scores developed for reporting TKA were unable to detect any difference between PFA and TKA. There was no significant difference in complications between PFA and TKA. PFAs were found to have a better postoperative range of motion. Conclusion. TKA and PFA are both viable options for patients with primary PFJ OA. Over time, we have seen an emphasis on patient satisfaction and better quality of life. Recommending sacrificing healthy medial and lateral compartments to treat patellofemoral joint arthritis should be given further thought. Cite this article: Bone Jt Open 2023;4(12):948–956


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 249 - 255
1 Mar 2024
Inclan PM Brophy RH Saccone NL Ma Y Pham V Yanik EL

Aims. The purpose of this study is to determine an individual’s age-specific prevalence of total knee arthroplasty (TKA) after cruciate ligament surgery, and to identify clinical and genetic risk factors associated with undergoing TKA. Methods. This study was a retrospective case-control study using the UK Biobank to identify individuals reporting a history of cruciate ligament surgery. Data from verbal history and procedural codes recorded through the NHS were used to identify instances of TKA. Patient clinical and genetic data were used to identify risk factors for progression from cruciate ligament surgery to TKA. Individuals without a history of cruciate ligament reconstruction were used for comparison. Results. A total of 2,576 individuals with a history of cruciate ligament surgery were identified, with 290 (11.25%) undergoing TKA. In patients with prior cruciate ligament surgery, prevalence of TKA was 0.75% at age 45 years, 9.10% at age 65 years, and 20.43% at age 80 years. Patients with prior cruciate ligament surgery were 4.6 times more likely to have undergone TKA by age 55 years than individuals without prior cruciate ligament surgery. In the cruciate ligament surgery cohort, BMI > 30 kg/m. 2. (odds ratio (OR) 4.01 (95% confidence interval (CI) 2.74 to 5.87)), a job that always involved heavy manual or physical labour (OR 2.72 (95% CI 1.57 to 4.71)), or a job that always involved walking and standing (OR 2.58 (95% CI 1.58 to 4.20)) were associated with greater TKA odds. No single-nucleotide polymorphism (SNP) was associated with risk of TKA following cruciate ligament surgery. Conclusion. Patients with a history of prior cruciate ligament surgery have substantially higher risk of TKA and undergo arthroplasty at a relatively younger age than individuals without a history of prior cruciate ligament surgery. Physically demanding work and obesity were associated with higher odds of TKA after cruciate ligament surgery, but no SNP was associated with risk of TKA. Cite this article: Bone Joint J 2024;106-B(3):249–255


The Bone & Joint Journal
Vol. 105-B, Issue 12 | Pages 1271 - 1278
1 Dec 2023
Rehman Y Korsvold AM Lerdal A Aamodt A

Aims. This study compared patient-reported outcomes of three total knee arthroplasty (TKA) designs from one manufacturer: one cruciate-retaining (CR) design, and two cruciate-sacrificing designs, anterior-stabilized (AS) and posterior-stabilized (PS). Methods. Patients scheduled for primary TKA were included in a single-centre, prospective, three-armed, blinded randomized trial (n = 216; 72 per group). After intraoperative confirmation of posterior cruciate ligament (PCL) integrity, patients were randomly allocated to receive a CR, AS, or PS design from the same TKA system. Insertion of an AS or PS design required PCL resection. The primary outcome was the mean score of all five subscales of the Knee injury and Osteoarthritis Outcome Score (KOOS) at two-year follow-up. Secondary outcomes included all KOOS subscales, Oxford Knee Score, EuroQol five-dimension health questionnaire, EuroQol visual analogue scale, range of motion (ROM), and willingness to undergo the operation again. Patient satisfaction was also assessed. Results. Patients reported similar levels of pain, function, satisfaction, and general health regardless of the prosthetic design they received. Mean maximal flexion (129° (95% confidence interval (CI) 127° to 131°) was greater in the PS group than in the CR (120° (95% CI 121° to 124°)) and AS groups (122° (95% CI 120° to 124°)). Conclusion. Despite differences in design and constraint, CR, AS, and PS designs from a single TKA system resulted in no differences in patient-reported outcomes at two-year follow-up. PS patients had statistically better ROM, but the clinical significance of this finding is unclear. Cite this article: Bone Joint J 2023;105-B(12):1271–1278


Aims. The use of high tibial osteotomy (HTO) to delay total knee arthroplasty (TKA) in young patients with osteoarthritis (OA) and constitutional deformity remains debated. The aim of this study was to compare the long-term outcomes of TKA after HTO compared to TKA without HTO, using the time from the index OA surgery as reference (HTO for the study group, TKA for the control group). Methods. This was a case-control study of consecutive patients receiving a posterior-stabilized TKA for OA between 1996 and 2010 with previous HTO. A total of 73 TKAs after HTO with minimum ten years’ follow-up were included. Cases were matched with a TKA without previous HTO for age at the time of the HTO. All revisions were recorded. Kaplan-Meier survivorship analysis was performed using revision of metal component as the endpoint. The Knee Society Score, range of motion, and patient satisfaction were assessed. Results. Mean follow-up was 13 years (SD 3) after TKA in both groups. The 20-year Kaplan-Meier survival estimate was 98.6% in TKA post-HTO group (HTO as timing reference) and 81.4% in control group (TKA as timing reference) (p = 0.030). There was no significant difference in clinical outcomes, radiological outcomes, and complications at the last follow-up. Conclusion. At the same delay from index surgery (HTO or TKA), a strategy of HTO followed by TKA had superior knee survivorship compared to early TKA at long term in young patients. Level of evidence: III. Cite this article: Bone Jt Open 2023;4(2):62–71


Aims. The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients. Methods. A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up. Results. There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group. Conclusion. There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA. Cite this article: Bone Joint J 2024;106-B(8):826–833


The Bone & Joint Journal
Vol. 105-B, Issue 1 | Pages 35 - 46
1 Jan 2023
Mills K Wymenga AB Bénard MR Kaptein BL Defoort KC van Hellemondt GG Heesterbeek PJC

Aims. The aim of this study was to compare a bicruciate-retaining (BCR) total knee arthroplasty (TKA) with a posterior cruciate-retaining (CR) TKA design in terms of kinematics, measured using fluoroscopy and stability as micromotion using radiostereometric analysis (RSA). Methods. A total of 40 patients with end-stage osteoarthritis were included in this randomized controlled trial. All patients performed a step-up and lunge task in front of a monoplane fluoroscope one year postoperatively. Femorotibial contact point (CP) locations were determined at every flexion angle and compared between the groups. RSA images were taken at baseline, six weeks, three, six, 12, and 24 months postoperatively. Clinical and functional outcomes were compared postoperatively for two years. Results. The BCR-TKA demonstrated a kinematic pattern comparable to the natural knee’s screw-home mechanism in the step-up task. In the lunge task, the medial CP of the BCR-TKA was more anterior in the early flexion phase, while laterally the CP was more posterior during the entire movement cycle. The BCR-TKA group showed higher tibial migration. No differences were found for the clinical and functional outcomes. Conclusion. The BCR-TKA shows a different kinematic pattern in early flexion/late extension compared to the CR-TKA. The difference between both implants is mostly visible in the flexion phase in which the anterior cruciate ligament is effective; however, both designs fail to fully replicate the motion of a natural knee. The higher migration of the BCR-TKA was concerning and highlights the importance of longer follow-up. Cite this article: Bone Joint J 2023;105-B(1):35–46


Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320


Bone & Joint Open
Vol. 4, Issue 9 | Pages 682 - 688
6 Sep 2023
Hampton M Balachandar V Charalambous CP Sutton PM

Aims. Aseptic loosening is the most common cause of failure following cemented total knee arthroplasty (TKA), and has been linked to poor cementation technique. We aimed to develop a consensus on the optimal technique for component cementation in TKA. Methods. A UK-based, three-round, online modified Delphi Expert Consensus Study was completed focusing on cementation technique in TKA. Experts were identified as having a minimum of five years’ consultant experience in the NHS and fulfilling any one of the following criteria: a ‘high volume’ knee arthroplasty practice (> 150 TKAs per annum) as identified from the National joint Registry of England, Wales, Northern Ireland and the Isle of Man; a senior author of at least five peer reviewed articles related to TKA in the previous five years; a surgeon who is named trainer for a post-certificate of comletion of training fellowship in TKA. Results. In total, 81 experts (round 1) and 80 experts (round 2 and 3) completed the Delphi Study. Four domains with a total of 24 statements were identified. 100% consensus was reached within the cement preparation, pressurization, and cement curing domains. 90% consensus was reached within the cement application domain. Consensus was not reached with only one statement regarding the handling of cement during initial application to the tibial and/or femoral bone surfaces. Conclusion. The Cementing Techniques In Knee Surgery (CeTIKS) Delphi consensus study presents comprehensive recommendations on the optimal technique for component cementing in TKA. Expert opinion has a place in the hierarchy of evidence and, until better evidence is available these recommendations should be considered when cementing a TKA. Cite this article: Bone Jt Open 2023;4(9):682–688


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 28 - 37
1 Jan 2024
Gupta S Sadczuk D Riddoch FI Oliver WM Davidson E White TO Keating JF Scott CEH

Aims. This study aims to determine the rate of and risk factors for total knee arthroplasty (TKA) after operative management of tibial plateau fractures (TPFs) in older adults. Methods. This is a retrospective cohort study of 182 displaced TPFs in 180 patients aged ≥ 60 years, over a 12-year period with a minimum follow-up of one year. The mean age was 70.7 years (SD 7.7; 60 to 89), and 139/180 patients (77.2%) were female. Radiological assessment consisted of fracture classification; pre-existing knee osteoarthritis (OA); reduction quality; loss of reduction; and post-traumatic OA. Fracture depression was measured on CT, and the volume of defect estimated as half an oblate spheroid. Operative management, complications, reoperations, and mortality were recorded. Results. Nearly half of the fractures were Schatzker II AO B3.1 fractures (n = 85; 47%). Radiological knee OA was present at fracture in 59/182 TPFs (32.6%). Primary management was fixation in 174 (95.6%) and acute TKA in eight (4.4%). A total of 13 patients underwent late TKA (7.5%), most often within two years. By five years, 21/182 12% (95% confidence interval (CI) 6.0 to 16.7) had required TKA. Larger volume defects of greater depth on CT (median 15.9 mm vs 9.4 mm; p < 0.001) were significantly associated with TKA requirement. CT-measured joint depression of > 12.8 mm was associated with TKA requirement (area under the curve (AUC) 0.766; p = 0.001). Severe joint depression of > 15.5 mm (hazard ratio (HR) 6.15 (95% CI 2.60 to 14.55); p < 0.001) and pre-existing knee OA (HR 2.70 (95% CI 1.14 to 6.37); p = 0.024) were independently associated with TKA requirement. Where patients with severe joint depression of > 15.5 mm were managed with fixation, 11/25 ultimately required TKA. Conclusion. Overall, 12% of patients aged ≥ 60 years underwent TKA within five years of TPF. Severe joint depression and pre-existing knee arthritis were independent risk factors for both post-traumatic OA and TKA. These features should be investigated as potential indications for acute TKA in older adults with TPFs. Cite this article: Bone Joint J 2024;106-B(1):28–37


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 102 - 108
1 Feb 2023
MacDessi SJ Oussedik S Abdel MP Victor J Pagnano MW Haddad FS

Orthopaedic surgeons are currently faced with an overwhelming number of choices surrounding total knee arthroplasty (TKA), not only with the latest technologies and prostheses, but also fundamental decisions on alignment philosophies. From ‘mechanical’ to ‘adjusted mechanical’ to ‘restricted kinematic’ to ‘unrestricted kinematic’ — and how constitutional alignment relates to these — there is potential for ambiguity when thinking about and discussing such concepts. This annotation summarizes the various alignment strategies currently employed in TKA. It provides a clear framework and consistent language that will assist surgeons to compare confidently and contrast the concepts, while also discussing the latest opinions about alignment in TKA. Finally, it provides suggestions for applying consistent nomenclature to future research, especially as we explore the implications of 3D alignment patterns on patient outcomes. Cite this article: Bone Joint J 2023;105-B(2):102–108


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 582 - 588
1 Jun 2024
Bertram W Howells N White SP Sanderson E Wylde V Lenguerrand E Gooberman-Hill R Bruce J

Aims. The aim of this study was to describe the prevalence and patterns of neuropathic pain over one year in a cohort of patients with chronic post-surgical pain at three months following total knee arthroplasty (TKA). Methods. Between 2016 and 2019, 363 patients with troublesome pain, defined as a score of ≤ 14 on the Oxford Knee Score pain subscale, three months after TKA from eight UK NHS hospitals, were recruited into the Support and Treatment After Replacement (STAR) clinical trial. Self-reported neuropathic pain and postoperative pain was assessed at three, nine, and 15 months after surgery using the painDETECT and Douleur Neuropathique 4 (DN4) questionnaires collected by postal survey. Results. Symptoms of neuropathic pain were common among patients reporting chronic pain at three months post-TKA, with half reporting neuropathic pain on painDETECT (191/363; 53%) and 74% (267/359) on DN4. Of those with neuropathic pain at three months, half continued to have symptoms over the next 12 months (148/262; 56%), one-quarter had improved (67/262; 26%), and for one-tenth their neuropathic symptoms fluctuated over time (24/262; 9%). However, a subgroup of participants reported new, late onset neuropathic symptoms (23/262; 9%). Prevalence of neuropathic symptoms was similar between the screening tools when the lower cut-off painDETECT score (≥ 13) was applied. Overall, mean neuropathic pain scores improved between three and 15 months after TKA. Conclusion. Neuropathic pain is common in patients with chronic pain at three months after TKA. Although neuropathic symptoms improved over time, up to half continued to report painful neuropathic symptoms at 15 months after TKA. Postoperative care should include screening, assessment, and treatment of neuropathic pain in patients with early chronic postoperative pain after TKA. Cite this article: Bone Joint J 2024;106-B(6):582–588


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1202 - 1208
1 Nov 2022
Klasan A Rice DA Kluger MT Borotkanics R McNair PJ Lewis GN Young SW

Aims. Despite new technologies for total knee arthroplasty (TKA), approximately 20% of patients are dissatisfied. A major reason for dissatisfaction and revision surgery after TKA is persistent pain. The radiological grade of osteoarthritis (OA) preoperatively has been investigated as a predictor of the outcome after TKA, with conflicting results. The aim of this study was to determine if there is a difference in the intensity of pain 12 months after TKA in relation to the preoperative radiological grade of OA alone, and the combination of the intensity of preoperative pain and radiological grade of OA. Methods. The preoperative data of 300 patients who underwent primary TKA were collected, including clinical information (age, sex, preoperative pain), psychological variables (depression, anxiety, pain catastrophizing, anticipated pain), and quantitative sensory testing (temporal summation, pressure pain thresholds, conditioned pain modulation). The preoperative radiological severity of OA was graded according to the Kellgren-Lawrence (KL) classification. Persistent pain in the knee was recorded 12 months postoperatively. Generalized linear models explored differences in postoperative pain according to the KL grade, and combined preoperative pain and KL grade. Relative risk models explored which preoperative variables were associated with the high preoperative pain/low KL grade group. Results. Pain 12 months after TKA was not associated with the preoperative KL grade alone. Significantly increased pain 12 months after TKA was found in patients with a combination of high preoperative pain and a low KL grade (p = 0.012). Patients in this group were significantly more likely to be male, younger, and have higher preoperative pain catastrophizing, higher depression, and lower anxiety (all p ≤ 0.05). Conclusion. Combined high preoperative pain and low radiological grade of OA, but not the radiological grade alone, was associated with a higher intensity of pain 12 months after primary TKA. This group may have a more complex cause of pain that requires additional psychological interventions in order to optimize the outcome of TKA. Cite this article: Bone Joint J 2022;104-B(11):1202–1208


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims. Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results. The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion. We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients. Cite this article: Bone Jt Open 2024;5(2):101–108


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


Bone & Joint Open
Vol. 3, Issue 5 | Pages 441 - 447
23 May 2022
Mikkelsen M Wilson HA Gromov K Price AJ Troelsen A

Aims. Treatment of end-stage anteromedial osteoarthritis (AMOA) of the knee is commonly approached using one of two surgical strategies: medial unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). In this study we aim to investigate if there is any difference in outcome for patients undergoing UKA or TKA, when treated by high-volume surgeons, in high-volume centres, using two different clinical guidelines. The two strategies are ‘UKA whenever possible’ vs TKA for all patients with AMOA. Methods. A total of 501 consecutive AMOA patients (301 UKA) operated on between 2013 to 2016 in two high-volume centres were included. Centre One employed clinical guidelines for the treatment of AMOA allowing either UKA or TKA, but encouraged UKA wherever possible. Centre Two used clinical guidelines that treated all patients with a TKA, regardless of wear pattern. TKA patients were included if they had isolated AMOA on preoperative radiographs. Data were collected from both centres’ local databases. The primary outcome measure was change in Oxford Knee Score (OKS), and the proportion of patients achieving the patient-acceptable symptom state (PASS) at one-year follow-up. The data were 1:1 propensity score matched before regression models were used to investigate potential differences. Results. The matched cohort included 400 patients (mean age 67 years (SD 9.55), 213 (53%) female, mean BMI 30.2 kg/m. 2. , 337 (84%) American Society of Anesthesiologists grade ≤ 2). We found a mean adjusted difference in change score of 3.02 points (95% confidence interval (CI) 1.41 to 4.63; p < 0.001) and a significantly larger likeliness of achieving PASS (odds ratio 3.67 (95% CI 1.73 to 8.45); p = 0.001) both in favour of the UKA strategy. Conclusion. UKA and TKA are both good strategies for treating end-stage AMOA. However, when compared as a strategy, UKA achieved larger improvements in OKS, and were more likely to reach the PASS value at one-year follow-up. Cite this article: Bone Jt Open 2022;3(5):441–447


Bone & Joint Open
Vol. 4, Issue 10 | Pages 808 - 816
24 Oct 2023
Scott CEH Snowden GT Cawley W Bell KR MacDonald DJ Macpherson GJ Yapp LZ Clement ND

Aims. This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up. Methods. From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed. Results. At 15 years, 28 patients were lost to follow-up (6.1%) and 221 patients (51.9%) had died, with the mean age of the remaining cohort reducing by four years. PROMs response rates among surviving patients were: one-year 63%; five-year 72%; ten-year 94%; and 15-year 59%. OKS and SF-12 scores changed significantly over 15 years (p < 0.001). The mean improvement in OKS was 18.8 (95% confidence (CI) 16.7 to 19.0) at one year. OKS peaked at five years (median 43 years) declining thereafter (p < 0.001), though at 15 years it remained 17.5 better than preoperatively. Age and sex did not alter this trajectory. A quarter of patients experienced a clinically significant decline (≥ 7) in OKS from five to ten years and from ten to 15 years. The SF-12 physical component score displayed a similar trajectory, peaking at one year (p < 0.001). Patient satisfaction was 88% at one, five, and ten years, and 94% at 15 years. In all, 15-year Kaplan-Meier survival was 97.6% (95% CI 96.0% to 99.2%) for any revision, and 98.9% (95% CI 97.9% to 99.9%) for aseptic revision. Conclusion. Improvements in PROMs were significant and maintained following single radius TKA, with OKS peaking at five years, and generic physical health peaking at one year. Patient satisfaction remained high at 15 years, at which point 2.4% had been revised. Cite this article: Bone Jt Open 2023;4(10):808–816


The Bone & Joint Journal
Vol. 105-B, Issue 6 | Pages 610 - 621
1 Jun 2023
Prodromidis AD Chloros GD Thivaios GC Sutton PM Pandit H Giannoudis PV Charalambous CP

Aims. Loosening of components after total knee arthroplasty (TKA) can be associated with the development of radiolucent lines (RLLs). The aim of this study was to assess the rate of formation of RLLs in the cemented original design of the ATTUNE TKA and their relationship to loosening. Methods. A systematic search was undertaken using the Cochrane methodology in three online databases: MEDLINE, Embase, and CINAHL. Studies were screened against predetermined criteria, and data were extracted. Available National Joint Registries in the Network of Orthopaedic Registries of Europe were also screened. A random effects model meta-analysis was undertaken. Results. Of 263 studies, 12 were included with a total of 3,861 TKAs. Meta-analysis of ten studies showed high rates of overall tibial or femoral RLLs for the cemented original design of the ATTUNE TKA. The overall rate was 21.4% (95% confidence interval (CI) 12.7% to 33.7%) for all types of design but was higher for certain subgroups: 27.4% (95% CI 13.4% to 47.9%) for the cruciate-retaining type, and 29.9% (95% CI 15.6% to 49.6%) for the fixed-bearing type. Meta-analysis of five studies comparing the ATTUNE TKA with other implants showed a significantly higher risk of overall tibial or femoral RLLs (odds ratio (OR) 2.841 (95% CI 1.219 to 6.623); p = 0.016) for the ATTUNE. The rates of loosening or revision for loosening were lower, at 1.2% and 0.9% respectively, but the rates varied from 0% to 16.3%. The registry data did not report specifically on the original ATTUNE TKA or on revision due to loosening, but ‘all-cause’ five-year revision rates for the cemented ATTUNE varied from 2.6% to 5.9%. Conclusion. The original cemented ATTUNE TKA has high rates of RLLs, but their clinical significance is uncertain given the overall low associated rates of loosening and revision. However, in view of the high rates of RLLs and the variation in the rates of loosening and revision between studies and registries, close surveillance of patients who have undergone TKA with the original ATTUNE system is recommended. Cite this article: Bone Joint J 2023;105-B(6):610–621


Bone & Joint Open
Vol. 3, Issue 6 | Pages 470 - 474
7 Jun 2022
Baek J Lee SC Ryu S Kim J Nam CH

Aims. The purpose of this study was to compare the clinical outcomes, mortalities, implant survival rates, and complications of total knee arthroplasty (TKA) in patients with or without hepatitis B virus (HBV) infection over at least ten years of follow-up. Methods. From January 2008 to December 2010, 266 TKAs were performed in 169 patients with HBV (HBV group). A total of 169 propensity score–matched patients without HBV were chosen for the control group in a one-to-one ratio. Then, the clinical outcomes, mortalities, implant survival rates, and complications of TKA in the two groups were compared. The mean follow-up periods were 11.7 years (10.5 to 13.4) in the HBV group and 11.8 years (11.5 to 12.4) in the control group. Results. The mean Knee Society scores in the HBV and control groups improved from 37.1 (SD 5.6) and 38.4 (SD 5.4) points preoperatively to 78.1 (SD 10.8) and 81.7 (SD 10.2) points at final follow-up (p = 0.314), while the mean function scores in the HBV and control groups improved from 36.2 and 37.3 points preoperatively to 77.8 and 83.2 points at final follow-up (p = 0.137). Nine knees in the HBV group required revision surgery, including seven due to septic loosening and two due to aseptic loosening. Four knees in the control group required revision surgery, including three due to septic loosening and one due to aseptic loosening. Kaplan–Meier survivorship analysis with the revision of either component as an endpoint in the HBV and control groups estimated 96.6% and 98.5% chances of survival for ten years, respectively (p = 0.160). Conclusion. TKA in patients with HBV infection resulted in good clinical outcomes and survivorship. However, there was a higher revision rate over a minimum ten-year follow-up period compared to TKA in patients without HBV infection. Cite this article: Bone Jt Open 2022;3(6):470–474


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236