Advertisement for orthosearch.org.uk
Results 1 - 50 of 112
Results per page:
Bone & Joint Research
Vol. 13, Issue 9 | Pages 474 - 484
10 Sep 2024
Liu Y Li X Jiang L Ma J

Aims

Rotator cuff tear (RCT) is the leading cause of shoulder pain, primarily associated with age-related tendon degeneration. This study aimed to elucidate the potential differential gene expressions in tendons across different age groups, and to investigate their roles in tendon degeneration.

Methods

Linear regression and differential expression (DE) analyses were performed on two transcriptome profiling datasets of torn supraspinatus tendons to identify age-related genes. Subsequent functional analyses were conducted on these candidate genes to explore their potential roles in tendon ageing. Additionally, a secondary DE analysis was performed on candidate genes by comparing their expressions between lesioned and normal tendons to explore their correlations with RCTs.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 4 | Pages 489 - 495
1 Apr 2006
Matthews TJW Hand GC Rees JL Athanasou NA Carr AJ

We have studied cellular and vascular changes in different stages of full thickness tears of the rotator cuff. We examined biopsies from the supraspinatus tendon in 40 patients with chronic rotator cuff tears who were undergoing surgery and compared them with biopsies from four uninjured subscapularis tendons. Morphological and immunocytochemical methods using monoclonal antibodies directed against leucocytes, macrophages, mast cells, proliferative and vascular markers were used.

Histological changes indicative of repair and inflammation were most evident in small sized rotator cuff tears with increased fibroblast cellularity and intimal hyperplasia, together with increased expression of leucocyte and vascular markers. These reparative and inflammatory changes diminished as the size of the rotator cuff tear increased. Marked oedema and degeneration was seen in large and massive tears, which more often showed chondroid metaplasia and amyloid deposition. There was no association between the age of the patient and the duration of symptoms. In contrast, large and massive tears showed no increase in the number of inflammatory cells and blood vessels.

Small sized rotator cuff tears retained the greatest potential to heal, showing increased fibroblast cellularity, blood vessel proliferation and the presence of a significant inflammatory component. Tissue from large and massive tears is of such a degenerative nature that it may be a significant cause of re-rupture after surgical repair and could make healing improbable in this group.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 7 | Pages 942 - 948
1 Jul 2011
Chaudhury S Holland C Vollrath F Carr AJ

This study reports the application of a novel method for quantitatively determining differences in the mechanical properties of healthy and torn rotator cuff tissues. In order to overcome problems of stress risers at the grip-tendon interface that can obscure mechanical measurements of small tendons, we conducted our investigation using dynamic shear analysis.

Rotator cuff tendon specimens were obtained from 100 patients during shoulder surgery. They included 82 differently sized tears and 18 matched controls. We subjected biopsy samples of 3 mm in diameter to oscillatory deformation under compression using dynamic shear analysis. The storage modulus (G’) was calculated as an indicator of mechanical integrity.

Normal tendons had a significantly higher storage modulus than torn tendons, indicating that torn tendons are mechanically weaker than normal tendons (p = 0.003). Normal tendons had a significantly higher mean shear modulus than tendons with massive tears (p < 0.01).

Dynamic shear analysis allows the determination of shear mechanical properties of small tissue specimens obtained intra-operatively that could not be studied by conventional methods of tensile testing. These methods could be employed to investigate other musculoskeletal tissues. This pilot study provides some insight into mechanisms that might contribute to the failure of repair surgery, and with future application could help direct the most appropriate treatment for specific rotator cuff tears.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 1 | Pages 151 - 153
1 Jan 1992
Brooks C Revell W Heatley F

Previous perfusion studies of the rotator cuff have demonstrated an area of hypovascularity in the distal part of the supraspinatus tendon. This has been implicated in the pathogenesis of its rupture. We performed a quantitative histological analysis of the vascularity of the tendons of supraspinatus and infraspinatus. Vessel number, size and the percentage of the tendon occupied by vessels were measured at 5 mm intervals from the humeral insertions to the muscle bellies. Both tendons were hypovascular in their distal 15 mm. No significant difference was demonstrated between the vascularity of supraspinatus and infraspinatus. We conclude that factors other than vascularity are important in the pathogenesis of supraspinatus rupture.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 107 - 107
2 Jan 2024
Park H
Full Access

The rotator cuff tendinopathy is one of the most common shoulder problems leading to full-thickness rotator cuff tendon tear and, eventually, to degenerative arthritis. Recent research on rotator cuff tendon degeneration has focused on its relationship to cell death. The types of cell death known to be associated with rotator cuff tendon degeneration are apoptosis, necrosis, and autophagic cell death. The increased incidence of cell death in degenerative tendon tissue may affect the rates of collagen synthesis and repair, possibly weakening tendon tissue and increasing the risk of tendon rupture. The biomolecular mechanisms of the degenerative changes leading to apoptotic cell death in rotator cuff tenofibroblasts have been identified as oxidative-stress-related cascade mechanisms. Furthermore, apoptosis, necrosis, and autophagic cell death are all known to be mediated by oxidative stress, a condition in which ROS (reactive oxygen species) are overproduced. Lower levels of oxidative stress trigger apoptosis; higher levels mediate necrosis. Although the signaltransduction pathway leading to autophagy has not yet been fully established, ROS are known to be essential to autophagy. A neuronal theory regarding rotator cuff degeneration has been developed from the findings that glutamate, a neural transmitter, is present in increased concentrations in tendon tissues with tendinopathy and that it induces rat supraspinatus tendon cell death. Recent studies have reported that hypoxia involved in rotator cuff tendon degeneration. Because antioxidants are known to scavenge for intracellular ROS, some studies have been conducted to determine whether antioxidants can reduce cell death in rotator cuff tendon-origin fibroblasts. The first study reported that an antioxidant has the ability to reduce apoptosis in oxidative-stressed rotator cuff tenofibroblasts. The second study reported that antioxidants have both antiapoptotic effects and antinecrotic effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The third study reported that an antioxidant has antiautophagic-cell-death effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The fourth study reported that glutamate markedly increases cell death in rotator cuff tendonorigin fibroblasts. The glutamate-induced cytotoxic effects were reduced by an antioxidant, demonstrating its cytoprotective effects against glutamate-induced tenofibroblast cell death. The fifth study reported that hypoxia significantly increases intracellular ROS and apoptosis. The hypoxia-induced cytotoxic effects were markedly attenuated by antioxidants, demonstrating their cytoprotective effects against hypoxia-induced tenofibroblast cell death. In conclusion, antioxidants have cytoprotective effects on tenofibroblasts exposed in vitro to an oxidative stressor, a neurotransmitter, or hypoxia. These cytoprotective effects result from antiapoptotic, antinecrotic, and antiautophagic actions involving the inhibition of ROS formation. These findings suggest that antioxidants may have therapeutic potential for rotator cuff tendinopathy. Further studies must be conducted in order to apply these in vitro findings to clinical situations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 30 - 30
2 Jan 2024
Park H Kim R
Full Access

Glutamate regulates the expression of apoptosis-related genes and triggers the apoptosis of fibroblasts in rotator cuff tendons. Subacromial bursitis is always accompanied by symptomatic rotator cuff tear (RCT). However, no study has been reported on the presence of glutamate in subacromial bursa and on its involvement of shoulder pain in patients who had RCT. The purposes of this study were to determine whether the glutamate expression in subacromial bursa is associated with the presence of RCT and with the severity of shoulder pain accompanying RCT. Subacromial bursal tissues were harvested from patients who underwent arthroscopic rotator cuff tendon repair or glenoid labral repair with intact rotator cuff tendon. Glutamate tissue concentrations were measured, using a glutamate assay kit. Expressions of glutamate and its receptors in subacromial bursae were histologically determined. The sizes of RCT were determined by arthroscopic findings, using the DeOrio and Cofield classification. The severity of shoulder pain was determined, using visual analog scale (VAS). Any associations between glutamate concentrations and the size of RCT were evaluated, using logistic regression analysis. The correlation between glutamate concentrations and the severity of pain was determined, using the Pearson correlation coefficient. Differences with a probability <0.05 were considered statistically significant. Glutamate concentrations showed significant differences between the torn tendon group and the intact tendon group (P = 0.009). Concentrations of glutamate significantly increased according to increases in tear size (P < 0.001). In histological studies, the expressions of glutamate and of its ionotropic and metabotropic receptors have been confirmed in subacromial bursa. Glutamate concentrations were significantly correlated with pain on VAS (Rho=0.56 and P =0.01). The expression of glutamate in subacromial bursa is significantly associated with the presence of RCT and significantly correlated with its accompanying shoulder pain. Acknowledgements: This research was supported by the Basic Science Research Program, through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2015R1D1A3A01018955 and 2017R1D1A1B03035232)


Bone & Joint Research
Vol. 8, Issue 3 | Pages 118 - 125
1 Mar 2019
Doi N Izaki T Miyake S Shibata T Ishimatsu T Shibata Y Yamamoto T

Objectives. Indocyanine green (ICG) fluorescence angiography is an emerging technique that can provide detailed anatomical information during surgery. The purpose of this study is to determine whether ICG fluorescence angiography can be used to evaluate the blood flow of the rotator cuff tendon in the clinical setting. Methods. Twenty-six patients were evaluated from October 2016 to December 2017. The participants were categorized into three groups based on their diagnoses: the rotator cuff tear group; normal rotator cuff group; and adhesive capsulitis group. After establishing a posterior standard viewing portal, intravenous administration of ICG at 0.2 mg/kg body weight was performed, and fluorescence images were recorded. The time from injection of the drug to the beginning of enhancement of the observed area was measured. The hypovascular area in the rotator cuff was evaluated, and the ratio of the hypovascular area to the anterolateral area of the rotator cuff tendon was calculated (hypovascular area ratio). Results. ICG fluorescence angiography allowed for visualization of blood flow in the rotator cuff in all groups. The adhesive capsulitis group showed significantly earlier enhancement than the other groups. Furthermore, the adhesive capsulitis group had a significantly smaller hypovascular area ratio than the other groups. Conclusion. ICG fluorescence angiography allowed for evaluation of real-time blood flow of the rotator cuff in arthroscopic shoulder surgery. The techniques of ICG fluorescence angiography are simple and easy to observe, observer reliability is high, and it has utility for evaluating blood flow during surgery. Cite this article: N. Doi, T. Izaki, S. Miyake, T. Shibata, T. Ishimatsu, Y. Shibata, T. Yamamoto. Intraoperative evaluation of blood flow for soft tissues in orthopaedic surgery using indocyanine green fluorescence angiography: A pilot study. Bone Joint Res 2019;8:118–125. DOI: 10.1302/2046-3758.83.BJR-2018-0151.R1


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 42 - 42
1 May 2012
Chaudhury S Holland C Porter D Vollrath F Carr AJ
Full Access

Background. High re-rupture rates following repairs of rotator cuff tears (RCTs) have resulted in the increased use of repair grafts to act as temporary scaffolds to support tendon healing. It has been estimated that thousands of extracellular matrix repair grafts are used annually to augment surgical repair of rotator cuff tears. The only mechanical assessment of the suitability of these grafts for rotator cuff repair has been made using tensile testing only, and compared grafts to canine infraspinatus. As the shoulder and rotator cuff tendons are exposed to shearing as well as uniaxial loading, we compared the response of repair grafts and human rotator cuff tendons to shearing mechanical stress. We used a novel technique to study material deformation, dynamic shear analysis (DSA). Methods. The shear properties of four RCT repair grafts were measured (Restore, GraftJacket, Zimmer Collagen Repair and SportsMesh). 3mm-sized biopsy samples were taken and subjected to DSA using oscillatory deformation under compression to calculate the storage modulus (G') as an indicator of mechanical integrity. To assess how well the repair grafts were matched to normal rotator cuff tendons, the storage modulus was calculated for 18 human rotator cuff specimens which were obtained from patients aged between 22 and 89 years (mean age 58.8 years, with 9 males and 9 females). Control human rotator cuff tendons were obtained from the edge of tendons during hemiarthoplasties and stabilisations. A 1-way ANOVA of all of the groups was performed to compare shear properties between the different commercially available repair grafts and human rotator cuff tendons to see if they were different. Specific comparison between the different repair grafts and normal rotator cuff tendons was done using a Dunn's multiple comparison test. Results. We report a significant difference in the shear moduli of all four rotator cuff repair grafts (P<0.0001, 1 way ANOVA, Kruskall-Wallis test). 2 of the grafts, Zimmer Collagen Repair and SportMesh, were not significantly different when compared to rotator cuff tendons and were found to have comparable shear mechanical properties (P > 0.05, Dunn's multiple comparison test). The other repair grafts, GraftJacket and Restore, had a significantly lower storage modulus when compared to human rotator cuff tendons. Conclusions. With increasing numbers of repairs of rotator cuff tears, and augmentation of these repairs, there is a need to understand the mechanical and biological properties of the both repair grafts and the tendons they are designed to augment. At present there is no clear definition of the ideal mechanobiological properties of rotator cuff repair patches. Current rotator cuff repair grafts display a wide variation in their shear mechanical properties, and how closely they are matched to the mechanical properties of human rotator cuff tendons. It is hoped that this study may help to guide surgeons in deciding on the most appropriate rotator cuff tendon repair graft


Bone & Joint Research
Vol. 3, Issue 8 | Pages 252 - 261
1 Aug 2014
Tilley JMR Murphy RJ Chaudhury S Czernuszka JT Carr AJ

Objectives . The effects of disease progression and common tendinopathy treatments on the tissue characteristics of human rotator cuff tendons have not previously been evaluated in detail owing to a lack of suitable sampling techniques. This study evaluated the structural characteristics of torn human supraspinatus tendons across the full disease spectrum, and the short-term effects of subacromial corticosteroid injections (SCIs) and subacromial decompression (SAD) surgery on these structural characteristics. . Methods . Samples were collected inter-operatively from supraspinatus tendons containing small, medium, large and massive full thickness tears (n = 33). Using a novel minimally invasive biopsy technique, paired samples were also collected from supraspinatus tendons containing partial thickness tears either before and seven weeks after subacromial SCI (n = 11), or before and seven weeks after SAD surgery (n = 14). Macroscopically normal subscapularis tendons of older patients (n = 5, mean age = 74.6 years) and supraspinatus tendons of younger patients (n = 16, mean age = 23.3) served as controls. Ultra- and micro-structural characteristics were assessed using atomic force microscopy and polarised light microscopy respectively. . Results. Significant structural differences existed between torn and control groups. Differences were identifiable early in the disease spectrum, and increased with increasing tear size. Neither SCI nor SAD surgery altered the structural properties of partially torn tendons seven weeks after treatment. . Conclusions . These findings may suggest the need for early clinical intervention strategies for torn rotator cuff tendons in order to prevent further degeneration of the tissue as tear size increases. Further work is required to establish the long-term abilities of SCI and SAD to prevent, and even reverse, such degeneration. Cite this article: Bone Joint Res 2014;3:252–61


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 419 - 419
1 Sep 2012
Chaudhury S Ferguson D Hakimi O Carr A
Full Access

INTRODUCTION. In order to address high failure rates following rotator cuff repairs, a greater understanding is required of the underlying structural changes so that treatments can be appropriately targeted and biomarkers of failure can be identified. As collagen is the primary constituent of tendon and determines force transmission, collagen structural changes may affect responses to loading. For example changes in collagen 1 and 5 are associated with the hyperelastic Ehlers-Danlos syndrome, which is diagnosed by looking for pathopneumonic altered collagen fibres or ‘collagen flowers’ in skin using transmission electron microscopy (TEM). To date no study has been performed on the microstructure of torn human rotator cuff tendons using TEM. It was hypothesized that normal, small and massive human rotator cuff tendons tears will have altered microscopic structures. The unique study aimed to use TEM to compare the ultrastructure of small and massive rotator cuff tears, to normal rotator cuff tendons. METHODS. Samples from 7 human rotator cuff tendons repairs were obtained, including 4 massive (>5 cm) and 3 small (< 1 cm) tears, and 3 matched normal controls with no history of connective tissue disorders. Specimens were fixed in 4% glutaraldehyde in 0.1M phosphate buffer, processed and examined blind using routine TEM examination. To assess whether changes in the relative expression of collagen 1 and 5 (COL1A1, COL5A1 and COL5A2) occurred in all tears, qPCR was performed on another 6 phenotypically matched patients. RESULTS. The basic structure of the normal tendon consisted of tightly packed clumps of dense packed parallel running collagen fibers with few fibroblasts and small amounts of fine filamentous material between clumps. In contrast, torn samples were more variable with areas of less dense packing of collagen fibers and larger areas of filamentous material plus variable numbers of lipid droplets both within the fibroblast and between the collagen bundles. There was also evidence of twisting and random orientation of individual collagen fibers. All torn tendons showed evidence of a proportion of the fibers within the collagen bundles being enlarged with a serrated outline, similar in appearance to ‘collagen flowers’. Clear differences between the small and massive tears were not identified. qRT-PCR of torn rotator cuff tendon specimens demonstrated no altered collagen expression compared to normal tendons. DISCUSSION. This novel study has identified the previously unreported presence of atypical collagen fibers with focal swelling resulting in the appearance of ‘collagen flowers’ in torn rotator cuff tendons only. This appearance is considered pathognomonic of Ehlers-Danlos syndrome, classical type 1 and 2. Torn tendons also showed an increase in filamentous material, and infiltration with fat droplets. These novel findings may offer insight into the mechanisms of structural damage that contribute to rotator cuff failure. Further examination is required, to evaluate the significance of these observations


The Bone & Joint Journal
Vol. 104-B, Issue 11 | Pages 1234 - 1241
1 Nov 2022
Park JH Park KT Kim SC Bukhary HA Lee SM Yoo JC

Aims. This study compared patients who underwent arthroscopic repair of large to massive rotator cuff tears (LMRCTs) with isolated incomplete repair of the tear and patients with incomplete repair with biceps tendon augmentation. We aimed to evaluate the additional benefit on clinical outcomes and the capacity to lower the re-tear rate. Methods. We retrospectively reviewed 1,115 patients who underwent arthroscopic rotator cuff repair for full-thickness tears between October 2011 and May 2019. From this series, we identified 77 patients (28 male, 49 female) with a mean age of 64.1 years (50 to 80). Patients were classified into groups A (n = 47 incomplete) and B (n = 30 with biceps augmentation) according to the nature of their reconstruction. Clinical scores were checked preoperatively and at six months, one year, and two years postoperatively. In preoperative MRI, we measured the tear size, the degree of fatty infiltration, and muscle volume ratio of the supraspinatus. In postoperative MRI, the integrity of the repaired rotator cuff tendon was assessed using the Sugaya classification. Tendon thickness at the footprint was evaluated on T2-weighted oblique coronal view. Results. There were no significant differences in the initial preoperative demographic characteristics. In both groups, there were significant improvements in postoperative clinical scores (p < 0.001). However, most clinical outcomes, including range of motion measurements (forward elevation, external rotation, internal rotation, and abduction), showed no differences between the pre- and postoperative values. Comparing the postoperative outcomes of both groups, no further improvement from biceps augmentation was found. Group B, although not reaching statistical significance, had more re-tears than group A (30% vs 15%; p = 0.117). Conclusion. In LMRCTs, biceps augmentation provided no significant improvement of an incomplete repair. Therefore, biceps augmentation is not recommended in the treatment of LMRCTs. Cite this article: Bone Joint J 2022;104-B(11):1234–1241


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 346 - 346
1 May 2009
Chen J Willers C Xu J Wang A Zheng M
Full Access

Large and retracted rotator cuff tendon tears fail to repair, or re-tear following surgical intervention. This study attempted to develop novel tissue engineering approaches using tenocytes-seeded bioscaffolds for tendon reconstruction of massive rotator cuff tendon defect in rabbits. Porcine small intestine submucosa (Restore™) and type I/III collagen bioscaffold (ACI-MaixTM) were chosen as bioscaffold carriers for autologous tenocytes. Biological characterization of autologous tenocytes was conducted prior to the implantation. The tenocyte-seeded bioscaffolds were implanted as interposition grafts to reconstruct massive rotator cuff tendon defects in rabbits. In situ re-implantation of the autologous rotator cuff tendon, excised during defect creation served as a positive control. Histological outcomes were analysed and semi-quantitatively graded at four and eight weeks after surgery. The results demonstrate that at four weeks both tenocyte-seeded bioscaffolds display inflammatory reaction similar to bioscaffold-only cuff reconstruction and the histological grading were inferior to control repair. However, at eight weeks inflammatory reaction of both tenocyte-seeded bioscaffolds were dramatically reduced as compared to bioscaffold alone. In addition, bioscaf-folds seeded with tenocytes generated similar histological appearance to that of the positive control. The implantation of autologous tenocytes on collagen-based bioscaffold offers improved rotator cuff tendon healing and remodelling compared to the implantation of bioscaffold alone


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 488 - 488
1 Apr 2004
Zheng M Xu J Chen J Willers C Wood D
Full Access

Introduction Rotator cuff degeneration is considered to be a major factor in the pathogenesis of rotator cuff tendon tear. Degenerative weakening of the rotator cuff can result in irreversible complete cuff-tear arthropathy syndrome. Recently a porcine small intestinal submucosa (SIS) has been approved by TGA as biological implant for the repair of rotator cuff tendon tear. The aims of this study are to evaluate the safety and efficacy of SIS. Methods A commercial brand of SIS was examined by histology and PCR technique. The material was implanted into mice and rabbits for the evaluation of biological reaction and inflammatory response. Next, we have used SIS to replace the rotator cuff tendon in rabbit (N=10) and compared to control (N=10). Histological examination was conducted at four and eight weeks after implantation. To further confirm if cells present in SIS material were of porcine origin, nested PCR for the amplification of DAP12 gene was used. Results Fresh SIS membrane before implantation contain multiple layers of spindle-shaped cells mixed with a small population of round-shaped cells. Chloroacetate esterase staining showed that the round-shaped cells are positive, indicating that they are mast cells. The tissue architecture of SIS mimics tendon structure as evidenced by H & E staining. The SIS membrane contained porcine DNA materials. Subcutaneous implant of SIS in mice (by six) for up to seven days showed no obvious inflammatory response or foreign body reaction. The result demonstrated that SIS has remained in the region and mixed with regenerative fibrous tissue after eight weeks. In some cases there was a massive recruitment of lymphocytes along the surface of membrane. However, no foreign body reactive giant cells were observed. Conclusions The result of this study indicated that SIS contains porcine cells and nucleic acid, which contradicts current views that SIS is a cell free biomaterial. Although no foreign body reaction of SIS was observed, SIS implant may cause chronic inflammation. Further studies should be conducted to confirm the clinical efficacy of SIS implant for rotator cuff tendon tear


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 32 - 32
2 Jan 2024
Traweger A
Full Access

Approximately 30% of general practice consultations for musculoskeletal pain are related to tendon disorders, causing substantial personal suffering and enormous related healthcare costs. Treatments are often prone to long rehabilitation times, incomplete functional recovery, and secondary complications following surgical repair. Overall, due to their hypocellular and hypovascular nature, the regenerative capacity of tendons is very poor and intrinsically a disorganized scar tissue with inferior biomechanical properties forms after injury. Therefore, advanced therapeutic modalities need to be developed to enable functional tissue regeneration within a degenerative environment, moving beyond pure mechanical repair and overcoming the natural biological limits of tendon healing. Our recent studies have focused on developing biologically augmented treatment strategies for tendon injuries, aiming at restoring a physiological microenvironment and boosting endogenous tissue repair. Along these lines, we have demonstrated that the local application of mesenchymal stromal cell-derived small extracellular vesicles (sEVs) has the potential to improve rotator cuff tendon repair by modulating local inflammation and reduce fibrotic scarring. In another approach, we investigated if the local delivery of the tendon ECM protein SPARC, which we previously demonstrated to be essential for tendon maturation and tissue homeostasis, has the potential to enhance tendon healing. Finally, I will present results demonstrating the utility of nanoparticle-delivered, chemically modified mRNAs (cmRNA) to improve tendon repair


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 39 - 39
4 Apr 2023
Lim W Lie D Chou S Lie H Yew A
Full Access

This study aims to investigate the mechanical properties of a rotator cuff tear repaired with a polypropylene interposition graft in an ovine infraspinatus ex-vivo model. Twenty fresh shoulders from skeletally mature sheep were used in this study. A tear size of 20 mm from the tendon joint was created in the infraspinatus tendon to simulate a large tear in fifteen specimens. This was repaired with a polypropylene mesh used as an interposition graft between the ends of the tendon. Eight specimens were secured with mattress stitches while seven were secured to the remnant tendon on the greater tuberosity side by continuous stitching. Remaining five specimens with an intact tendon served as a control group. All specimens underwent cyclic loading with a universal testing machine to determine the ultimate failure load and gap distance. Gap distance increased with progressive cyclic loading through 3000 cycles for all repaired specimens. Mean gap distance after 3000 cycles for both continuous and mattress groups are 1.7 mm and 4.2 mm respectively (P = .001). Significantly higher mean ultimate failure load was also observed with 549.2 N in the continuous group, 426.6 N in the mattress group and 370 N in the intact group. The use of a polypropylene mesh as an interposition graft for large irreparable rotator cuff tears is biomechanically suitable and results in a robust repair that is comparable to an intact rotator cuff tendon. When paired with a continuous suturing technique, it demonstrates significantly resultant superior biomechanical properties that may potentially reduce re-tear rates after repairing large or massive rotator cuff tears


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 414 - 414
1 Sep 2012
Chaudhury S Holland C Porter D Vollrath F Carr A
Full Access

Introduction. The pathophysiology of high failure rates following rotator cuff tendon repairs, particularly massive tears, is not fully understood. Collagen structural changes have been shown to alter tendon thermal and mechanical properties. Thermal changes in small biopsies, detected by differential scanning calorimetry (DSC) can help to quantify collagen structural differences in torn rotator cuff tendons. This study aimed to form a quantitative rather than qualitative assessment, of whether differences in collagen structure and integrity existed between small biopsies of normal, small and massive rotator cuff tears using DSC. Methods. Thermal properties were measured for 27 human biopsies taken intra-operatively from normal, small, and massive rotator cuff tendon tears. 3 samples were taken from each patient and subjected to a modulated temperature ramp between 20–80°C at a rate of 2°C per minute with 0.318°C amplitude. The melting temperature (TM) is proposed to represent amide-amide hydrogen bond breakage and resulting protein backbone mobility. Denaturing temperature (TD) reportedly corresponds to the temperature at which the proteins fall out of solution. Denaturation enthalpy (H) should correlate with the amount of triple helical structure. Based upon a pre-study power calculation, this study had 90% power to detect a 10% difference in melting and denaturation temperature between groups with alpha=0.05. 1 specimen per patients was also frozen and cryosectioned and polarised light microscopy was used for quantitative validation. The effect of tear size on heat related parameters were performed using a one-way ANOVA test. A student's unpaired t-test was used to search for differences between individual groups (small tears, massive tears and normal tendons). Results. Small and massive rotator cuff tears had significantly higher melting temperature (TM), and denaturation enthalpy (H) compared to controls. The denaturing temperature (TD) was higher in the massive tears only compared to normal tears. No difference was detected between small and massive tears. Histology of massive tendon tears confirmed greater collagen structural disruption compared to small tears and controls. Conclusion. These novel findings suggest greater quantifiable collagen structural disruption in rotator cuff tears, compared to controls. A decrease in important thermal properties of torn tendons suggests that the material is intrinsically less stable. It is likely that torn tendons cannot withstand changes in temperature or stress as well as a perfect material could, particularly for massive tears which are more amenable to denaturation. This study offers insight into possible mechanisms for, or adaptation to, failure in tears and reduced strength


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 252 - 252
1 Jul 2014
Mouthuy P Hakimi O Baboldashti NZ Morrey M Lostis E Carr A
Full Access

Summary Statement. This study describes the design and preliminary in vitro testing of a novel patch for the repair of rotator cuff tendon tears. The laminated design incorporates woven and electrospun components. The woven element provides the patch with excellent mechanical strength and the electrospun layer improves cell attachment and promotes cell orientation and diferentiation. Introduction. Aligned nanofibrous electrospun scaffolds have been previously proposed as ideal scaffolds for tendon repair, replicating the anisotropy of tendon and providing a biomimetic design to encourage tissue regeneration (Hakimi et al., 2012). However, such scaffolds are still limited in terms of mechanical properties. This paper presents the design of a novel patch for rotator cuff repair in which the electrospun scaffold is supported by a woven component. Patients & Methods. Aligned polydioxanone (PDO) electrospun scaffolds were produced using a single nozzle electrospinning set-up with a rotating collector. The woven component was created by weaving PDO monofilaments with a manual loom. The woven and non-woven constituents were bound by a non-destructive method which preserves the surface morphology of the electrospun material. For each type of scaffold, a minimum of 3 specimens were tested to failure in tension using Zwick machine at rate of 0.3 mm/min until failure. For in vitro work, human-derived tendon cells were extracted from rotator cuff tendon tissue obtained during surgical repair, with appropriate ethical approval. Cells were cultured on the scaffolds for at least 14 days. Results. The contribution of the woven component to the tensile strength of the assembled patch is about 20 times more when compared to the electrospun scaffold. In vitro work shows that human tenocytes grown on the nanofibrous non-woven electrospun component align in the direction of the fibre orientation. The appearance of the woven component is shown. Discussion/Conclusion. While the woven component provides most of the mechanical strength, the aligned electrospun fibres enable cell orientation along the axis of the patch. These cells display a similar morphology to tenocytes in native tendons. With the combination of biomimetic features and good mechanical properties, this novel PDO patch is an excellent candidate material to support tendon repair


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 352 - 352
1 Jul 2008
Matthews T Brinsden M Hand C Rees J Athanasou N Carr A
Full Access

A prospective study was carried out to determine if recognised histological features seen at surgery could help predict those rotator cuff tendon repairs which re-ruptured. 40 rotator cuff tendon edge specimens from 40 patients’ shoulders were analysed histologically following routine mini-open rotator cuff repair. 32/40 underwent Ultrasonography, at a mean time of 35 months post-operatively, to determine repair integrity. The histological features seen at surgery were then compared to the repair integrity of the tendon from which it had been taken. Rotator cuff repairs that remained intact demonstrated a greater reparative response, in terms of increased fibrobast cellularity, cell proliferation and a thickened synovial membrane, than those repairs which reruptured. Larger tears which remained intact showed a higher degree of vasacularity and a significant inflammatory component than those that re-ruptured. Good tissue quality at the time of surgery allows the repair the best chance of remaining intact despite the size of the lesion. Routine histological analysis of the tissue biopsy, preformed in the post-operatively, can now aid the clinician in terms of early management and repair prognosis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 52 - 52
1 May 2012
S. C C. D F. V A. C
Full Access

Background. Rotator cuff tears pose a huge socioeconomic burden. Our study uses Fourier transform infrared spectroscopy (FTIR) as it is a quick, non-manipulative and non-destructive test, which can identify a wide range of chemical targets from small intraoperatively obtained specimens. The aim of this study was (i) to characterise the chemical and structural composition of rotator cuff tendons and (ii) to identify structural differences between anatomically distinct tear sizes. Such information may help to identify specific biomarkers of rotator cuff tear pathologies, which in turn could allow early identification and monitoring of disease progression. FTIR may provide insight into the different healing rates of different tear sizes. Methods. The infrared spectra of 81 torn rotator cuff tendons were measured using a FTIR spectrometer. The rotator cuff tear sizes were classified as partial, small, medium, large and massive, and compared to 14 normal controls. All spectra were classified using standard multivariate analysis; principal component analysis, partial least square and discriminant function analysis. Results. FTIR readily differentiated between normal and torn tendons, and different tear sizes. We identified the key discriminating molecules and spectra altered in torn tendons as: (i) carbohydrates/phospholipids (1030-1200 cm. -1. ), (ii) collagen (1300-1700, 3000-3350 cm. -1. ) and (iii) lipids (2800-3000 cm. -1. ). Partial tears were chemically distinct from normal and small tears, and primarily involved a reduction in collagen type II. Conclusion. This study has demonstrated that FTIR can identify different sizes of rotator cuff tear based upon distinguishable chemical and structural features. The onset of rotator cuff tear pathology is mainly due to alterations of the collagen structural arrangements, with associated changes in lipids and carbohydrates. The approach described is rapid and has the potential to be used intraoperatively to determine the quality of the tendon and extent of disease, thus guiding surgical repairs or for monitoring of treatments


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 333 - 333
1 Sep 2005
Wood D Xu J Chen J Willers C Zheng M
Full Access

Introduction and Aims: Treatment of rotator cuff tendon tear presents a significant therapeutic challenge to surgeons. Porcine small intestinal submucosa (SIS) is a biomaterial approved by TGA and FDA for the repair of rotator cuff tendon tear. The aims of this study are to evaluate the safety and efficacy of SIS. Method: SIS purchased from DePuy Johnson & Johnson was examined by histology and PCR technique. The material was also implanted into mice and rabbits for the evaluation of biological reaction and inflammatory response. Porcine immunoreceptor DAP12 gene was used to examine if the material contained porcine DNA. Results: Fresh SIS membrane before implantation contains multiple layers of spindle-shaped cells mixed with a small population of round-shaped cells. Chloro-acetate esterase staining showed that the round-shaped cells are positive, indicating that they are mast cells. The tissue architecture of SIS mimics to tendon structure as evidenced by H& E staining. To further confirm if cells present in SIS material were porcine origin, nested PCR for the amplification of DAP12 gene was used. The result demonstrated that SIS membrane contain porcine DNA materials. Conclusion: SIS contains porcine cells and nuclei acid, which contradicts with current views that SIS is a cell-free biomaterial. Although no foreign body reaction of SIS was observed, SIS implant may cause chronic inflammation. Further studies should be conducted to confirm the clinical efficacy of SIS implant


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 280 - 280
1 Mar 2004
Kolts I Tomusk H Raudheiding A Eller A Busch L
Full Access

Aims: The aim of the study was to investigate the cap-suloligamentous structures of the shoulder joint and their association with rotator cuff tendons. Methods: Twenty seven alcohol-formalin-glycerol þxed right shoulder joints (age range 65 Ð 78 years) were investigated. The Ligg. coracohumerale, coracoglenoidale, glenohumeralia, semicirculare humeri and gleno-capsulare were dissected in þne detail. To visualise the rotator interval, the Processus coracoideus was cut at its base and moved together with the Ligg. coracohumerale and coracoglenoidale posteriorly. The analysis of the ligamentous structures and their relations with the rotator cuff tendons was performed. Results: The Lig. coracohumerale originated from Processus coracoideus and Lig. coracoglenoidale. It inserted into the Lig.semicirculare humeri Ð a capsular ligament spread between Tubercula minus et majus. Lig. glenocapsulare originated posterior to the Tuberculum supragle-noidale and inserted into the Lig. semicirculare humeri. The Mm. supra- and infraspinatus inserted into the Lig. semicirculare humeri. The anterior capsule was strengthened in addition to the three Ligg. glenohumeralia with a Lig. glenohumerale spirale. It originated from the Tuberculum infraglenoidale, coursed craniolaterally and inserted together with the M. subscapularis tendon at the Tuberculum minus. Conclusions: The shoulder joint capsule is strengthened with the Ligg. coracohumerale, coracoglenoidale, glenohumeralia superior, medium, inferior et spirale and Ligg. semicirculare humeri et glenocapsulare. The close relation of the ligamentous structures with the tendons of the rotator cuff brings a new insight into the different glenohumeral pathologies


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 391 - 391
1 Sep 2005
Loebenberg M Pelled G Hoffman A Zilberman Y Shinar H Keinan-Adamsky K Navon G Gross G Gazit D
Full Access

Introduction: New biotechnologies create opportunities for gene therapy to promote rotator cuff healing. We have previously demonstrated that genetically engineered mesenchymal stem cells (MSCs) over expressing BMP-2 and SMAD8 signaling molecule differentiate to tenocytes in vitro and in vivo. Therefore, we hypothesized that rotator cuff defect could be regenerated using genetically engineered MSCs. Method: Nonviral methods were utilized to establish genetically engineered MSCs that co-express BMP-2 and the Smad8 signaling molecule. A previously validated animal model was utilized to examine rotator cuff healing. A 2mm x2mm full thickness defect was created in the infraspinatus tendon of 8 nude rats. A collagen-I biomembrane (TissueMend) containing 3 x 10. 6. engineered cells was sewn into the defect. An identical control procedure was repeated on the contralateral side with biomembrane containing non-engineered MSCs. Results: 4 weeks post implantation the area of implantation was isolated and analyzed by light microscopy and histochemical staining. Analysis of the engineered implants revealed the formation of dense connective tissue with parallel-organized fibers and spindle shaped cells, unlike the control samples. Proton Double Quantum Filtered Magnetic Resonance Imaging technique of the rotator cuff tendons demonstrated an increased presence of organized collagen fibers within the engineered rotator cuff tissue when compared with either native rotator cuff or those treated with non-engineered MSCs. Conclusion: This is the first report showing rotator cuff tendon repair using genetically engineered MSCs. Moreover these findings may have considerable importance for tendon healing and may indicate a clinical gene therapy platform to augment surgical repair


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 164 - 164
1 Apr 2005
Matthews T Smith S Urban J Carr A
Full Access

Aim To determine if tissue metabolism varies in supraspinatus tendons with distance from the edge of the rotator cuff tendon tear and also with differing size of tear. Background Tissue metabolism can be assessed by measuring oxygen and nitrous oxide concentrations within the tissue. Viable tendon tissue consumes oxygen and contains nitrous oxide (used in the general anaesthetic) from the blood stream. Non-viable tendon tissue will not consume oxygen but will contain nitrous oxide. Methods Oxygen and Nitrous Oxide concentrations were measured amperometrically using silver needle microelectrodes. The needle was inserted into the supraspinatus tendon of patients with massive, large, medium and small full thickness rotator cuff tears and patients with partial thickness and no tears. Patients undergoing open stabilisation were used as controls. Measurements were made at a number of quantifiable points from the tendon edge to allow the creation of a topographical map of tissue metabolism. Oxygen consumption was calculated using measured oxygen and nitrous oxide levels at each point. Results In patients with rotator cuff tears oxygen consumption was significantly lower near to the edge of the tear. Patients with impingement syndrome but no evidence of a rotator cuff tear also showed a decreased level of oxygen consumption in the anterior part of supraspinatus, but this was significantly higher than the levels seen in the torn tendon. The control group showed no significant alteration in oxygen levels. Conclusion Patients with rotator cuff tendon tear demonstrate significantly reduced levels of tissue metabolism. This reduction in tissue viability is significantly greater at the edge of the tear and in larger tears. Patients with intact tendons and impingement syndrome also demonstrate minor reduction in tissue tendon viability compared with controls


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 228 - 229
1 May 2009
Shore B Athwal GS Drosdowech DS Faber KJ Johnston JA Kedgley AE
Full Access

Rotator cuff tears are a common cause of shoulder pain and dysfunction. Therefore, the purpose of this in-vitro biomechanical study was conducted to determine the effects of simulated tears and subsequent repairs of the rotator cuff tendons on joint kinematics. Eight paired fresh-frozen cadaveric shoulder specimens (mean age: 66.0 ± 8.7 years) were tested using a custom loading apparatus designed to simulate unconstrained motion of the humerus. Cables were sutured to the rotator cuff tendons and the deltoid. Loads were applied to the cables based on variable ratios of electromyographic (EMG) data and average physiological cross-sectional area (pCSA) of the muscles. An electromagnetic tracking device (Flock of Birds, Ascension Technologies, VT) was used to provide real-time feedback of abduction angle, to which the loading ratio was varied correspondingly. 2 and 4cm tears were made starting at the rotator cuff interval and extending posteriorly. Specimens were randomised to receive either single or double suture anchor repair. In order to quantify repeatability, five successive tests on each of the intact, torn, and repaired cases were performed. Statistical significance was established using One- and Two-way Repeated Measured ANOVAs (p< 0.05). Rotator cuff tears caused alteration in glenohumeral kinematics. A 2cm tear caused the humerus to consistently move posterior through the arc of abduction; however, as the tear increased to 4cm the humerus moved anteriorly, returning towards the intact state. Double row suture anchor repairs more accurately reproduced the kinematics of the intact specimen compared to single row suture anchor repair. The initial posterior displacement in the plane of elevation with the sectioning of the supraspinatus is related to the diminished anterior moment on the glenohumeral joint. As the tear proceeds into the infraspinatus, the anterior and posterior forces become more balanced and a return to near normal intact kinematics was observed. This study demonstrates that double row suture anchor repair more accurately reproduces active shoulder kinematics of the intact shoulder specimens


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 1 - 1
1 Mar 2010
Williams D Wojewnik B Tonino P Mikolyzk D Callaci J Himes R Wei A Magovern B Volkmer D Wezeman FH Marra G
Full Access

Purpose: To determine if administration of recombinant bFGF in an alginate gel would increase early healing mechanical parameters in acutely injured rat rotator cuff tendon at specific time points. Method: Sprague Dawley rats were randomly divided into 2 groups and had surgically created 1mm (half tendon width) full thickness injuries at exactly 2mm from insertion site of Infraspinatus on the humerus. 200ng of bFGF or vehicle control was administered to randomly chosen rats. Tendons were harvested at 1 week, 2 weeks and 4 weeks. In both groups, the Infraspinatus tendon was dissected, and left attached to the humerus. At the time of testing, the intact portion of the injured tendon was divided sharply across tendon fibers at the level of the injury leaving only the healing tissue callus in continuity with the remaining proximal and distal portions of the tendon and loaded to failure. Results: At 1 week the injury group’s average load to failure was 0.60N versus 0.61N in the bFGF injury group P = 1.000. At 2 weeks the injury group’s average load to failure increased to 1.03N versus 2.08N in the bFGF injury group P = 0.440 At 4 weeks the injury group’s average load to failure increased to 3.93N versus 5.56N in the bFGF injury group P = 0.008 representing a 41% increase in ultimate load. At 4 weeks, callus size of the injury group was 0.4mm2 versus 2.7mm2 in the bFGF injury group P < 0.001. Stiffness at 4 weeks for the injury tendons was 2.15 N/mm versus 3.54 N/mm in the bFGF group P = 0.008. Conclusion: At 4 weeks healing tissue of acutely injured rotator cuff exposed to bFGF has an increase in ultimate load to failure (41% compared to control), increase in tendon callus size and stiffness. Our findings suggest a role of bFGF or similar growth factors in accelerating the healing of injured rotator cuff tendon


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 383 - 384
1 Sep 2005
Safran O Derwin K Powell K Iannotti J
Full Access

Background: Time dependent, quantitative studies of muscle atrophy or passive muscle mechanics following chronic muscle detachment have not been previously reported. We developed a chronic tear of the rotator cuff tendon in a canine model to investigate and quantify the time related changes in the passive mechanics, volume, and fat of the infraspinatus muscle. We hypothesize that infraspinatus muscle stiffness will increase, volume will decrease, and fat content will increase at 12-weeks following tendon detachment. Methods: The right infraspinatus tendons of eight adult mongrel dogs were surgically detached from the proximal humerus. The non-operated left shoulder served as a control. Muscle volume changes were quantified using MRI scans. At 12 weeks the passive mechanical properties of the chronically detached and control muscles were determined intraoperatively using a custom device. Intramuscular fat was evaluated histologically at sacrifice. Results: After 12 weeks of detachment, the stiffness and modulus were significantly increased in the detached infraspinatus muscles relative to controls. MRI analysis demonstrated that the detached muscle volumes decreased by 33 percent in the first 6 weeks and remained constant thereafter. Intramuscular fat increased significantly in the detached muscles, and to a greater extent in the lateral regions. Conclusions: The chronically detached muscle is not merely a smaller version of the original muscle but rather a “different” muscle. The detached muscle becomes stiffer and the passive loads required to repair it can become excessive. A significant reduction in muscle volume occurs within days to weeks following tendon detachment. The non-uniformity of muscle fat changes suggests that fat content should be used cautiously as an indicator of muscle quality. Clinical Relevance: Clinically, chronic, large rotator cuff tendon tears are observed to have a qualitatively shorter and stiffer muscle-tendon unit than normal. We have developed a chronic rotator cuff model to quantitatively investigate changes in the detached infraspinatus muscle. The passive mechanical properties of a chronically torn rotator cuff muscle-tendon unit may be a useful predictor of reparability and clinical outcome


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 49 - 49
1 Jul 2020
Lapner P Laneuville O Uhthoff HK Zhang T Howard L Pollock J Ruggiero S Trudel G
Full Access

Tears of the rotator cuff tendons are a very common entity. Despite recent advances in arthroscopic rotator cuff repair, the re-tear rate remains high. Thus, new methods to improve healing rates following rotator cuff repair must be sought. The purpose of this prospective randomized double-blind controlled study is to compare the functional outcomes and healing rates of an adjuvant pre-operative bone microfracture technique prior to arthroscopic cuff repair. Patients undergoing arthroscopic rotator cuff repair were randomized to receive either a percutaneous bone microfracture of the supraspinatus footprint or a “soft tissue needling” technique, in which the pin was passed through the peripheral edges of the rotator cuff, five-seven days prior to index surgery, under ultrasound guidance. Follow-ups were completed at 3, 6, 12 and 24 months post-operatively. Healing status was determined by ultrasound at 6 and 24 months. The primary objective was to compare the WORC score at 24 months. Secondary objectives included the healing status via ultrasound, the Constant, and the ASES scores. A sample size calculation determined that 90 patients provided 80% power to detect a statistical difference between groups. Baseline demographic data did not differ between groups. No statistical differences were detected in the WORC outcome at any time points (p=0.47, baseline, p=0.60, 3 months, p=0.79, 6 months, p=0.50, 12 months, p=0.54, 24 months). Healing rates did not differ between groups (P=0.34) and no differences were observed in the ASES or Constant Scores at all time-points. Statistically significant improvements occurred in both groups from baseline to all time points in all clinical outcome scores (p < 0 .0001). No statistically significant differences in primary or secondary outcomes were identified between pre-operative bone microfracture and soft tissue needling techniques prior to arthroscopic rotator cuff repair. This study does not support pre-operative microfracture as a adjuvant technique prior to arthroscopic cuff repair


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 227 - 227
1 Sep 2005
Durani P Jeon I McCulloch T McLeod A Wallace W
Full Access

Introduction: The Nottingham Hood is a polyester soft tissue reinforcement device for the treatment of weakened or torn rotator cuff tendons (RCTs). The device was introduced in 1987 and has undergone a number of modifications from a close weave polyester modified aortic vascular graft (Mark 1) to an embroidered trefoil shape (Mark 4 – Pearsall’s Ltd) which has now been available since 2000. While this device has been under development it has been used on a named patient basis for 10 years on humanitarian grounds as an alternative treatment option for patients with massive RCTs. Approximately 30 Nottingham Hoods have been inserted over the past 10 years. This study investigates the histological changes and ingrowth associated with this device. Methods: Four patients who have had the Nottingham Hood inserted for massive RCTs have had re-operations for various reasons on five occasions. Excised material from the rotator cuff has been subjected to histological investigation. Excised biopsy material has been obtained 6 weeks, 6, 9 & 12 months and 14 years following implantation. Transmitted and polarised light microscopy has been used in all cases. Results: At 6 weeks birefringent clear material similar to suture material was identified, invested by fibrin and occasional red cells i.e. old thrombus. The fibrin was partly calcified and insinuated between bundles of the meshwork material. No true ingrowth of material was seen at this stage. At 6 months the material was seen macroscopically to be covered with collagenous material, rather like fascia which interdigitated closely with the embedded polyester material. At 14 years the mesh appeared to be invested, sandwich-like into a collagenous fascia-like structure with dense hyaline bands of collagen. Some fibrin was also present between the fibrils and a low grade foreign body giant cell response with light chronic inflammation. The local synovium showed detritic synovitis. Discussion: The histological features show that there is an early organisational response to the insertion of the new tissue, which is then accompanied by long-term incorporation into host tissues by fibrosis and scarring. A small fibrin and foreign body response lingers on. Conclusion: This long-term follow-up assessment provides evidence that long-term implantation of polyester as reinforcement for the rotator cuff tendons is not associated with serious biological problems. However the problem of stretching of the repaired rotator cuff muscles does occur and needs to be considered in more depth


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 100 - 100
1 Jan 2004
Durani P Jeon I McCulloch T McLeod A Wallace W
Full Access

The Nottingham Hood is a polyester soft tissue reinforcement device for the treatment of weakened or torn rotator cuff tendons (RCTs). The device was introduced in 1987 and has undergone a number of modifications from a close weave polyester modified aortic vascular graft (Mark 1) to an embroidered trefoil shape (Mark 4 – Pearsall’s Ltd) which has now been available since 2000. While this device has been under development it has been used on a named patient basis for 10 years on humanitarian grounds as an alternative treatment option for patients with massive RCTs. Approximately 30 Nottingham Hoods have been inserted over the past 10 years. This study investigates the histological changes and ingrowth associated with this device. Four patients who have had the Nottingham Hood inserted for massive RCTs have had re-operations for various reasons on five occasions. Excised material from the rotator cuff has been subjected to histological investigation. Excised biopsy material has been obtained 6 weeks, 6, 9 & 12 months and 14 years following implantation. Transmitted and polarised light microscopy has been used in all cases. At 6 weeks birefringent clear material similar to suture material was identified, invested by fibrin and occasional red cells i.e. old thrombus. The fibrin was partly calcified and insinuated between bundles of the meshwork material. No true ingrowth of material was seen at this stage. At 6 months the material was seen macroscopically to be covered with collagenous material, rather like fascia which interdigitated closely with the embedded polyester material. At 14 years the mesh appeared to be invested, sandwich-like into a collagenous fascia-like structure with dense hyaline bands of collagen. Some fibrin was also present between the fibrils and a low grade foreign body giant cell response with light chronic inflammation. The local synovium showed detritic synovitis. The histological features show that there is an early organisational response to the insertion of the new tissue, which is then accompanied by long-term incorporation into host tissues by fibrosis and scarring. A small fibrin and foreign body response lingers on. This long-term follow-up assessment provides evidence that long-term implantation of polyester as reinforcement for the rotator cuff tendons is not associated with serious biological problems. However the problem of stretching of the repaired rotator cuff muscles does occur and needs to be considered in more depth


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 3 - 3
1 Feb 2020
Hartwell M Sweeney RHP Marra G Saltzman M
Full Access

Background. Rotator cuff atrophy evaluated with computed tomography scans has been associated with asymmetric glenoid wear and humeral head subluxation in glenohumeral arthritis. Magnetic resonance imaging has increased sensitivity for identifying rotator cuff pathology and has not been used to investigate this relationship. The purpose of this study was to use MRI to assess the association of rotator cuff muscle atrophy and glenoid morphology in primary glenohumeral arthritis. Methods. 132 shoulders from 129 patients with primary GHOA were retrospectively reviewed and basic demographic information was collected. All patients had MRIs that included appropriate orthogonal imaging to assess glenoid morphology and rotator cuff pathology and were reviewed by two senior surgeons. All patients had intact rotator cuff tendons. Glenoid morphology was assigned using the modified-Walch classification system (types A1, A2, B1, B2, B3, C, and D) and rotator cuff fatty infiltration was assigned using Goutallier scores. Results. 46 (35%) of the shoulders had posterior wear patterns (23 type B2s, 23 type B3s). Both the infraspinatus and teres minor independently had significantly more fatty infiltration in B2 and B3 type glenoids compared to type A glenoids (p<0.001). There was a greater imbalance in posterior rotator cuff muscle fatty atrophy in B2 and B3 type glenoids compared to type A glenoids (p<0.001). However, there was no difference in axial plane imbalance between B2 and B3 glenoids (p=1.00). There was increased amount fatty infiltration of the infraspinatus among B2 and B3-type glenoids compared to type A glenoids on multivariate analysis controlling for age and gender (p<0.001). Conclusions. These results identify significant axial plane rotator cuff muscle imbalances in B2 and B3-type glenoids compared to concentrically worn glenoids, favoring a relative increase in fatty infiltration of the infraspinatus and teres minor compared to the subscapularis in glenoids with patterns of posterior wear. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 333 - 333
1 Sep 2005
Wang A Chen J Zheng M
Full Access

Introduction and Aims: Large or recurrent rotator cuff tendon tears are difficult to treat effectively. Collagen bio-scaffolds have become available to reinforce a tendon repair or as an interpositional graft. This study compares the suitability of two collagen bio-scaffolds for autologous tenocyte implantation, and assesses the in vivo rotator cuff healing response with these grafts in a rabbit model. Method: Tenocytes were isolated from rabbit tendon, cultured and seeded onto the Restore patch (DePuy), or the Matricel (Verigen) collagen membrane. Serial scanning electron microscopy examined tenocyte integration with the bio-scaffold, and extra-cellular matrix synthesis over time. A rotator cuff tendon defect was created in 50 rabbits and repaired by either: a) direct suture to tuberosity; b) Matricel interposition graft; c) Matricel interposition with autologous tenocytes; d) Restore patch interposition graft; e) Restore patch interposition with autologous tenocytes. Gross and histological evaluation were performed at four weeks and eight weeks post-surgery. Results: Scanning electron microscopy of the Matricel membrane showed a rough surface characterised by a loose arrangement of collagen fibres capable of cell adhesion. SEM at one, three and five days after cell seeding, showed progressive integration of tenocytes into the three-dimensional membrane structure with extra-cellular matrix neosynthesis in the spaces between the native collagen fibres. SEM of the Restore patch showed a relatively smooth surface of highly compacted collagen fibres. Serial SEM after cell seeding showed relatively less tenocyte integration onto the membrane surface though tenocyte replication and matrix neo-synthesis was observed. All 50 rabbits regained normal gait at two weeks post-surgery. At sacrifice, no tendon ruptures had occurred at either time point in any of the five groups. At four weeks, the Matricel and Restore bio-scaffold membranes were partially absorbed, and a florid lymphocytic inflammatory response was evident surrounding the remaining membrane. By eight weeks, graft tissue had been resorbed further, the inflammatory response had decreased, and the regenerating tendon showed progressive remodelling. Autologous tenocyte implantation on both membranes improved the reparative tendon histological grade at eight weeks compared to membranes without cell implantation, and was equivalent to the direct repair group. Conclusion: Autologous tenocytes can be implanted onto both Matricel and Restore collagen bio-scaffolds. Though both Xeno grafts induce an anti-inflammatory response in vivo, membrane resorption subsequently occurs. The healing response of large rotator cuff defects treated with interpositional collagen grafts is improved with autologous tenocyte implantation in a rabbit model


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 57 - 57
1 Jul 2020
Chevrier A Hurtig M Lacasse F Lavertu M Potter H Pownder S Rodeo S Buschmann M
Full Access

Surgical reattachment of torn rotator cuff tendons can lead to satisfactory clinical outcome but failures remain common. Ortho-R product is a freeze-dried formulation of chitosan (CS) that is solubilized in platelet-rich plasma (PRP) to form injectable implants. The purpose of the current pilot study was to determine Ortho-R implant acute residency, test safety of different implant doses, and assess efficacy over standard of care in a sheep model. The infraspinatus tendon (ISP) was detached and immediately repaired in 22 skeletally mature ewes. Repair was done with four suture anchors in a suture bridge configuration (n = 6 controls). Freeze-dried formulations containing 1% w/v chitosan (number average molar mass 35 kDa and degree of deacetylation 83%) with 1% w/v trehalose (as lyoprotectant) and 42.2 mM calcium chloride (as clot activator) were solubilized with autologous leukocyte-rich PRP and injected at the tendon-bone interface and on top of the repaired site (n = 6 with a 1 mL dose and n = 6 with a 2 mL dose). Acute implant residency was assessed histologically at 1 day (n = 2 with a 1 mL dose and n = 2 with a 2 mL dose). Outcome measures included MRI assessment at baseline, 6 weeks and 12 weeks, histopathology at 12 weeks and clinical pathology. MRI images and histological slides were scored by 2 blinded readers (veterinarian and human radiologist, and veterinarian pathologist) and averaged. The Generalized Linear Model task (SAS Enterprise Guide 7.1 and SAS 9.4) was used to compare the different groups with post-hoc analysis to test for pairwise differences. Ortho-R implants were detected near the enthesis, near the top of the anchors holes and at the surface of ISP tendon and muscle at 1 day. Numerous polymorphonuclear cells were recruited to the implant in the case of ISP tendon and muscle. On MRI, all repair sites were hyperintense compared to normal tendon at 6 weeks and only 1 out 18 repair sites was isointense at 12 weeks. The tendon repair site gap seen on MRI, which is the length of the hyperintense region between the greater tuberosity and tendon with normal signal intensity, was decreased by treatment with the 2 mL dose when compared to control at 12 weeks (p = 0.01). Histologically, none of the repair sites were structurally normal. A trend of improved structural organization of the tendon (p = 0.06) and improved structural appearance of the enthesis (p = 0.1) with 2 mL dose treatment compared to control was seen at 12 weeks. There was no treatment-specific effect on all standard safety outcome measures, which suggests high safety. Ortho-R implants (2 mL dose) modulated the rotator cuff healing processes in this large animal model. The promising MRI and histological findings may translate into improved mechanical performance, which will be assessed in a future study with a larger number of animals. This study provides preliminary evidence on the safety and efficacy of Ortho-R implants in a large animal model that could potentially be translated to a clinical setting


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 6 - 6
1 Dec 2022
Roversi G Nusiner F De Filippo F Rizzo A Colosio A Saccomanno M Milano G
Full Access

Recent studies on animal models focused on the effect of preserving tendon remnant of rotator cuff on tendon healing. A positive effect by combining tendon remnant preservation and small bone vents on the greater tuberosity in comparison with standard tendon-to-bone repair has been shown. The purpose of the present clinical study was to evaluate the efficacy of biologic augmentation of arthroscopic rotator cuff repair by maintaining tendon remnant on rotator cuff footprint combined with small bone vents of the greater tuberosity. A retrospective study was conducted. All patients who underwent arthroscopic rotator cuff repair associated with small bone vents (nanofractures) and tendon footprint preservation were considered eligible for the study. Inclusion criteria were: diagnosis of full-thickness rotator cuff tear as diagnosed at preoperative magnetic resonance imaging (MRI) and confirmed at the time of surgery; minimum 24-month of follow-up and availability of post-operative MRI performed not earlier than 6 months after surgery. Exclusion criteria were: partial thickness tears, irreparable tears, capsulo-labral pathologies, calcific tendonitis, gleno-humeral osteoarthritis and/or previous surgery. Primary outcome was the ASES score. Secondary outcomes were: Quick-DASH and WORC scores, and structural integrity of repaired tendons by magnetic resonance imaging (MRI) performed six months after surgery. A paired t-test was used to compare pre- and postoperative clinical outcomes. Subgroup analysis was performed according to tear size. Significance was set at p < 0.05. The study included 29 patients (M:F = 15:14). Mean age (+ SD) of patients was 61.7 + 8.9 years. Mean follow-up was 27.4 ± 2.3 months. Comparison between pre- and postoperative functional scores showed significant clinical improvement (p < 0.001). Subgroup analysis for tear size showed significant differences in the QuickDASH score (0.04). Particularly, a significant difference in the QuickDASH score could be detected between medium and large tears (p=0.008) as well as medium and massive lesions (p=0.04). No differences could be detected between large and massive tears (p= 0.35). Postoperative imaging showed healed tendons in 21 out of 29 (72%) cases. Preservation of tendon remnant combined with small bone vents in the repair of medium-to-massive full-thickness rotator cuff tears provided significant improvement in clinical outcome compared to baseline conditions with complete structural integrity in 72% of the cases


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 30 - 30
1 Aug 2013
de Beer M
Full Access

Purpose:. The objective of this study was to determine the tensile strength of the different components of the rotator cuff tendons and their relationship to rotator cuff tears. Method:. The tests were done on a newly designed and built test-bench that performed the tests at a consistent rupture speed. The tests were done on four fresh frozen cadaver shoulders. The capsular and tendinous layers of the rotator cuff were divided leaving them only attached on the humeral side. Separate tensile tests were done on these tendons, after they were divided into 10 mm wide strips before testing. The tendon thickness was also measured. Results:. The maximum force tolerated by these tendons is comparable. The elongation however is not the same; the tendinous part of the tendon elongated more. The strength of the “rotatorhood” was then determined. This is a thin layer of tendon extending beyond the greater tuberosity, connecting the supra-spinatus to the sub-scapularis via the bicipital groove. The 10 mm of the “rotator hood” ruptured at an average force of 70 Newtons. Conclusion:. 1. The two layers of the rotator cuff contribute equally to the cuff's strength. 2. The difference in elongation of the tendinous and capsular layers makes the capsular layer more vulnerable to elongation stress. 3. The “rotatorhood” is a strong important structure with a mechanically advantageous insertion


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 27 - 27
1 Jan 2017
Chevalier Y Pietschmann M Thorwaechter C Chechik O Adar E Dekel A Mueller P
Full Access

Treatment of massive rotator cuff tears can be challenging. Previous studies with irreparable rotator cuff tears showed good clinical results of tendon healing with the arthroscopic insertion of a protective biodegradable spacer balloon filled with saline solution between the repaired tendon and the acromion [1,2], but so far no scientific evidence has showed how the device alters pressures over the repaired tendon. This biomechanical study investigated the effects of a spacer inserted in the subacromial space on pressures over the repaired rotator cuff tendon in passive motion cycles typical for post-operative rehabilitation routines. Six human cadaveric shoulders were prepared with the humerus cut 15cm below the joint and embedded in a pot, while the scapula fixed at three points on a plate. A rotator cuff tear was simulated and repaired using a suture anchor and a Mason-Allen suture. The specimens were then mounted on a custom-made pneumatic testing rig to induce passive motion cycles of adduction-abduction (90–0°) and flexion-extension (0–40°) with constant glenohumeral and superior loads and tension is exerted on the supraspinatus tendon with weights. A pressure sensor was placed between the supraspinatus tendon and the acromion. After pressure measurements for 15 cycles of each motion type, the InSpace balloon (OrthoSpace, Inc, Israel) was inserted and the specimens tested and pressure measured again for 15 cycles. Statistically significant changes in peak pressures were then measured before and after balloon. Peak pressures were measured near 90 degrees abduction. No statistical differences were observed for internal-external rotation before and after balloon-shaped subacromial spacer was inserted. Mean pressures in abduction-adduction were significantly reduced from 121.7 ± 9.5 MPa to 51.5 ± 1.2 MPa. Peak pressures after repair were 1171.3 ± 99.5 MPa and 1749.6 ± 80.7 MPa in flexion-extension and abduction-adduction motion, respectively, and significantly decreased to 468.7 ± 16.0 MPa and 535.1 ± 27.6 MPa after spacer insertion (p<0.0001). The use of the spacer above the repaired tendon reduced peak pressures and distributed them more widely over the sensor during both abduction-adduction and flexion-extension motions and therefore can reduce the stress on the rotator cuff repair. The InSpace system may reduce the pressure on the repaired tendon, thus potentially protecting the repair. Further studies to investigate this phenomenon are warranted, in particular relating these changes to shoulder kinematics following tear repair and spacer insertion


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2017
Wu J Zhou Z Zhao X Xue W Xu J Kirk T
Full Access

The health of a synovial joint is relied on normal function and coordination of a group of tissues such as articular cartilage (AC), ligaments, tendons and muscles. Osteoarthritis (OA), which is the most common joint disease, is clinically characterised by lesion of AC. Despite this, injury of a ligament or tendon or muscle generates a joint instability, which accelerates deterioration of AC and progression of OA. Traditional histology is often used to study the pathology of biological tissues. It requires tissue biopsy, which traumatises the donor tissues. Therefore, it is not an idea method for assessing AC, ligaments and tendons as the tissues have a poor healing capability. There is a worldwide demand of an imaging technique that diagnoses the microstructural changes of chondral and connective tissues without biopsy. Confocal arthroscopy (Optiscan Pty Ltd, Australia) possesses a Ø 6.3 mm probe and offers a 0.7 µm lateral imaging resolution and 7 µm axial resolution. It has been successfully used for examining the internal microstructural disorders in rotator cuff tendons of human cadavers without tissue biopsy (WU et al., 2015). This study investigates the capability of confocal arthroscopy as optical histology for assessing the internal microstructure of AC, ligaments, tendons and muscles in a knee joint. Four sheep keen joints were freshly donated by other research unrelated to this study. After 5 ml clinical grade fluorescein solution at 0.05 g/L was injected into the joint cavity of a knee joint, the joint was passively exercising for about 10 minutes. The joint was then open collaterally and washed thoroughly using PBS for acquiring the microstructure of AC, ligaments, tendons and muscles using the confocal arthroscopy. Results: without biopsy, confocal arthroscopy offers an imaging resolution for onsite distinguishing the subtle microstructural difference of AC in the weight-bearing and non-weight bearing region. It also permitted visualising the hierarchical collagen structure in ligaments and tendons at a fibre level, and characterising the muscle nuclei, motor-neurons, moto-neuron synapse and striates of myofibres. Confocal arthroscopy showed the early promise to act as optical histology for studying the microstructure of chondral and a range of connective tissues, which allows understand better the health status of a knee joint. Since a sheep knee joint is very small for operating a normal procedure of an arthroscopic examination, an open knee joint surgery was performed in this study to allow imaging the microstructure of AC and a range of connective tissues. This is accounted as a limitation in the study. Nevertheless, this study demonstrated the development of confocal arthroscopy may lead to optical histology of the internal microstructure of AC and a group of connective tissues, which offers understanding more comprehensively the healthy status of a knee joint


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 44 - 44
1 Jan 2003
Itoi E
Full Access

Anatomy of the rotator cuff tendons, their relationship to the greater tuberosity, and the tensile and compressive properties of the cuff tendons have been extensively studied recently. From these anatomical and biomechanical studies, it has been clarified that stress concentration at the anterior portion of the supraspinatus tendon, shearing force, and mechanical friction as well as the degenerative weakness of the cuff tendons can all play a role in the occurrence of a tear. Strength of initial repair is limited, and thus the arm after repair should be positioned such that undue tension at the repair site is eliminated


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 5 | Pages 723 - 726
1 Nov 1987
Kelly I Foster R Fisher W

Forty-two shoulders in 37 patients with polyarthritis were treated with Neer total shoulder replacements and reviewed 12 to 66 months afterwards. There was good pain relief and improvement in function, but the range of movement was less than that seen after replacements for osteoarthritis; this may have been related to the fact that 34 shoulders had abnormal rotator cuff tendons. Although there was a high incidence of radiolucent lines around the glenoid component, there was no clinical evidence of loosening. There were a few complications, but on the whole we feel that the Neer total shoulder arthroplasty is a valuable procedure for a patient with polyarthritis


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 5 | Pages 795 - 797
1 Nov 1988
Hawkins R Brock R Abrams J Hobeika P

This is a retrospective review of 108 patients who underwent decompressive anterior acromioplasty for chronic impingement in the absence of a full thickness rotator cuff tear. Before operation, all the patients had had shoulder pain for at least one year despite conservative treatment. At operation, the rotator cuff tendons were explored and were intact. Anterior acromioplasty, followed by rehabilitation was successful in 87% of patients. The operation was less successful in women, in those who had diminished movement before operation, who were involved in worker's compensation claims, and whose pain followed direct trauma. Appropriate selection of patients is considered the key to success


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 10 - 10
1 Apr 2012
Marsh A Fazzi U
Full Access

Massive, irreparable rotator cuff tears occur in about 15% of patients with ruptures of the rotator cuff tendons. There is no consistently agreed management for irreparable rotator cuff tears, however, latissimus dorsi tendon transfer is a recognised technique. We aimed to review the functional outcome of patients undergoing this operation at a single tertiary referral centre. Fourteen latissimus dorsi transfer procedures in thirteen patients from May 2007 to May 2008 were retrospectively reviewed. The mean age of patients undergoing the procedure was fifty nine years. All patients were confirmed to have massive, irreparable (>5cm) rotator cuff tears as determined by MRI or ultrasound. Modified Constant scores (assessing shoulder pain, functional activity and movement) determined pre-operatively and post latissmus dorsi transfer were compared. The mean duration of follow up was 12 months. The mean Modified Constant Score (maximum = 75) improved from 23 points pre-operaively to 52 points post latissimus dorsi transfer (p < 0.05). All patients had improvement in shoulder pain following the operation. There was a trend for younger patients to have greater improvement in functional activity and shoulder movement. From our series, latissimus dorsi transfer is effective at improving functional outcomes in patients with massive, irreparable rotator cuff tears, especially in younger age groups


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 275 - 276
1 Sep 2005
de Beer M Burger N van Rensburg J
Full Access

The objective of this study was to determine the tensile strength of the different components of rotator cuff tendons. A test bench that performs tests at consistent rupture speed was used to do separate tensile tests on 10-mm strips of capsular and tendinous layers in four fresh frozen cadaveric shoulders. The layers were left attached only on the humeral side. The maximum force was comparable but the elongation of the outer part of the tendon was greater, indicating that the capsular part would tear first. On average, a 10-mm strip of capsular layer failed at 170N with elongation of 7 mm, while a 10-mm strip of tendinous layer failed at 230N with elongation of 10 mm. Using six fresh frozen cadaveric shoulders, we went on to determine the strength of the rotator hood, a thin layer of tendon extending beyond the tuberosity major and connecting the supraspinatus to the subscapularis via the bicipital tunnel. The rotator hood ruptured at a mean force of 70 N. We concluded that the two layers of the cuff contribute equally to the strength. It is therefore important to repair both layers. The difference in elongation of the tendinous and capsular layers makes the capsular layer more vulnerable to elongation stress. The rotator hood is a strong and important structure, and it is important to repair it


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 339 - 339
1 Jul 2011
Tzanakakis N Mouzopoulos G Mataragas E Vassos C Antonogiannakis E
Full Access

To analyze the relationship between functional outcome and tissue quality after arthroscopic rotator cuff repair. One hundred and forty-five patients who had undergone arthroscopic repair of rotator cuff tear, during the period of 2003–2008, were evaluated. All operations were performed under the same surgeons. The mean follow-up period was 2.4±1.2 years (range, 0.5 to 5 ys). The patients were devided in two groups:. patients with good tissue quality and. patients with poor tissue quality. As good tissue quality is defined the tendon with enough mass for suturing (thickness> 3mm) and good elasticity (the footprint is covered properly under tendon traction with tissue grasper). The independent variable studied here was the tissue quality of rotator cuff tendon. Clinical outcomes preoperatively and postoperatively, were assessed with use of ASES, CONSTANT and UCLA scores. Statistical analysis was performed by using STATA 8.0. Good tissue quality was identified in 119 patients (82%) and poor tissue quality in 26 (18%) patients respectively. At the follow up the patients with good tissue quality achieved Constant score: 86.85±12.49, ASES score: 84±3.4, UCLA score: 28.7±1.9 and the patients with poor tissue quality achieved Constant score: 62.35±13.85, ASES score: 61.49±8.9, UCLA score: 21±3.2. Significant difference between the two groups concerning the clinical outcome was observed after adjusted the data for age. Besides high correlation was noticed between old age and increased rate of poor tissue quality (r=0.88). Better clinical outcomes are expected in patients associated with good tissue quality, adjusted for age. So the tissue quality is positively correlated with the final functional outcome


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 352 - 352
1 Jul 2008
Matthews T Rees J Urban J Carr A
Full Access

The aim of this study was to determine cell viability in different stages of rotator cuff tendon tears using a cell viability molecular probe. Surgical biopsies taken from the edge of the Supraspinatus tendon tear from12 patients, 5 women and 7 men, mean age of 61 years were subjected to a cell viability assay using Molecular Probes Live/Dead cell viability assay. Specimens were then incubated with Calcein-AM and Ethidium Homodimer-1 and following snap freezing, sections were viewed under fluorescent microscopy. Cells which remained metabolically active fluoresced green, whereas dead cells were red. Populations of live and dead cells were counted for each specimen on ten high powered (x400 magnification) fields of view. The results show that the percentage of live cells is reduced in large chronic degenerate tears but greatest in acute traumatic tears. In addition, for those cases where tissue was assayed from the edge of the tear and 1 cm more proximally, there was a considerable increase in the percentage of viable cells in more proximal tissue. Use of this simple assay demonstrates high cell viability and consequently good quality tissue in traumatic tears, but lower quality tissue in larger more degenerate tears. This suggests that traumatic lesions have a high propensity to heal while larger more degenerate tears are less likely to heal but have better quality tissue more proximally


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 34 - 34
1 Feb 2012
White C Bunker T Hooper R
Full Access

Given that there is limited time available to the surgeon in arthroscopic rotator cuff repair, how is the time best spent? Should they place one Modified Mason-Allen, two mattress or four simple sutures? This study reverses current thought. In an in-vitro biomechanical single pull to failure study we compared the ultimate tensile strength of simple, mattress and grasping sutures passed with an arthroscopic suture passer (Surgical Solutions Express-Sew). The aim was to determine which suture configurations would most simply, repeatably and reliably repair the rotator cuff. The ultimate tensile strength and mode of failure of six different suture configurations was repeatedly tested on a validated porcine rotator cuff tendon model, using a standard suture material (Number 2 Fiberwire) passed with the Surgical Solutions Express-sew, in a Hounsfield type H20K-W digital tensometer. Standardising the number of suture passes to four, the strongest construct was two mattress sutures (Mean 169N), followed by single Modified Kessler (Mean 161N), four simple sutures (Mean 155N) and finally a single Mason Allen suture (Mean 140N). Suture configurations involving two passes were all weaker than those with four (one way analysis of variance p=0.026), even when Number 2 Fibertape was used to augment strength. These results show little difference in strength for varying complexity of four pass suture passage (one way analysis of variance p=0.61). In simple terms there is no demonstrable difference in the strength of construct whether the surgeon uses four simple, two mattress or one grasping suture. This study allows the surgeon to justify using the simplest configuration of suture passage that works in his hands in order to obtain a reliable and repeatable repair of the rotator cuff arthroscopically


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 13 - 13
1 Mar 2009
Cerciello S Visci F Pezzillo F Maccauro G Di Gregorio F Nizegorodcew T
Full Access

Introduction: Antegrade intramedullary locked nailing is a reliable method for the treatment of humeral shaft fractures. There is a still debate on the functional effect due to a possible damage during surgical approach of the rotator cuff, but in the Literature few paper deal with the analysis of tendons in these patients. Ultrasonography is still considered a reliable method in evaluating rotator cuff tendons. The aim of this study is to evaluate if antegrade intramedullary nailing may induce a possible damage on rotator cuff. Methods: Between May 2002 to December 2005 42 patient suffering of humeral shaft fractures were surgically treated with Unreamed Humeral Nail. Of them 21 (13 males and 8 female) were followed (average follow-up 22,9 months). All the fractures were traumatic except 1 due to bone metastasis of carcinoma. Follow up was clinical with Constant Score, radiographic in 3 projection (neutral, internal and external), and ultrasonographic, evaluating tendon of m. Sovraspinosus. Results: Healing of fractures was obtained after 2 month from surgery in all cases; Constant Score’s average was 77,0. Three cases of impingement syndrome due to excessive length of nail were observed, healed after the nail removal. Ultrasonography showed that in 13 cases rotator cuff was normal. In 5 cases we have found a signicative hyperecogen area, related to the scarf. We have never had a damage of tendon in all its tickness. Conclusion: Our study confirms that antegrade intra-medullary nail is a reliable method for the treatment humeral shaft fractures, not adversely influenced shoulder tendons. Damage of rotator cuff observed in few cases is not related to surgical technique, but depends on surgical pitfall with an excessively long nail and then impingement syndrome


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 8 - 8
1 Mar 2008
Evans A Gillespie G Dabke H Lewis M Roberts P Kulkarni R
Full Access

Proximal humeral fractures are common and often occur in osteoporotic bone. Suture fixation utilises the rotator cuff tendons as well as bone providing adequate stability and avoids complications associated with metalwork insertion. Surgical exposure was via a delto-pectoral approach with minimal dissection of the fracture site. Initially a 2 suture technique was utilized with heavy ethibond sutures passed through drill holes either side of the bicipital groove; however, because of concerns about varus instability the technique now uses a third suture placed laterally acting as a tension band to prevent varus collapse. Patients with Neer 2 and 3 part fractures treated with suture fixation were assessed clinically (using the Constant score) and radiologically at a mean of 27 months post fracture. To date 24 patients have been studied. The average age of the patients in our series was 70.2. All fractures progressed to union with no cases of radiological avascular necrosis. We had 2 cases of mal-union (-one varus and one valgus-), both with a 2-suture technique. One patient had early loss of fixation; re-exploration was performed with stability conferred by a third lateral suture. Active abduction > 120o was achieved in 9 patients with a mean Constant score of 72 compared to 89 on the un-injured contra-lateral side. We have demonstrated that suture fixation of displaced proximal humeral fractures is an effective alternative to fixation using metalwork. The advantages are that minimal soft tissue stripping of the fracture site is required and the potential problems associated with metalwork insertion into osteoporotic bone are avoided. Following one case of varus mal-union with a 2-suture technique we now routinely use a third suture to act as a lateral tension band


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 171 - 172
1 Feb 2004
Triantafillopoulos I Bowman K Banes A Garrett W Karas S
Full Access

Aim: We hypothesize that anabolic steroid administration enhances matrix remodelling and improves the biomechanical properties of bio-artificially engineered human supraspinatus tendons (BATs). Method: BATs were treated either with nandrolone decanoate (NLS group, n=18), stretching (LNS group, n=18), or both (LS group, n=18). A control group received no treatment (NLNS group, n=18). BATs’ contractility was assessed by daily scanning and two dimensional analysis. Cytoskeletal organization was evaluated microscopically with DAPI and rhodamine phalloidin staining. Matrix metalloproteinase-3 (MMP-3) levels – an indicator of matrix remodelling – were discerned by ELISA assay, and biomechanical properties by load-to-failure testing. Results: The LS group showed greatest contractility and the best-organized actin cytoskeleton when compared to the other groups. On the second and third day of treatment, MMP-3 levels in the LS group were significantly greater than those of NLNS group and greater than NLS and LNS groups. The biomechanical properties (load to failure, ultimate stress, ultimate strain, elastic modulus, and energy to failure) in the LS group were significantly improved when compared to NLNS and NLS (p< .05) groups and 26–48% greater than those in LNS group. Conclusions: Nandrolone decanoate and load act synergistically to increase matrix remodelling and biomechanical properties of bioengineered human supraspinatus tendons. Carefully prescribed and monitored, anabolic steroids may have an important adjunct role in postoperative healing and rehabilitation of repaired rotator cuff tendons. More research is necessary to fully evaluate the safety and efficacy of anabolic steroids in this application


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 357 - 357
1 Jul 2008
White C Bunker T Hooper R
Full Access

Given that there is limited time available to the surgeon in arthroscopic rotator cuff repair, how is the time best spent? Should he place one Modified Mason-Allen, two mattress or four simple sutures? This study reverses current thought. In an in-vitro biomechanical single pull to failure study we compared the ultimate tensile strength of simple, mattress and grasping sutures passed with an arthroscopic suture passer (Surgical Solutions Express-Sew). The aim was to determine which suture configurations would most simply, repeatably and reliably repair the rotator cuff. The ultimate tensile strength and mode of failure of six different suture configurations was repeatedly tested on a validated porcine rotator cuff tendon model, using a standard suture material (Number 2 Fiberwire) passed with the Surgical Solutions Express-sew, in a Hounsfield type H20K-W digital tensometer. Standardising the number of suture passes to four, the strongest construct was two mattress sutures (Mean 169N), followed by single Modified Kessler (Mean 161N), four simple sutures (Mean 155N) and finally a single Mason Allen suture (Mean 140N). Suture configurations involving two passes were all weaker than those with four (one way analysis of variance p=0.026), even when Number 2 Fibertape was used to augment strength. These results show little difference in strength for varying complexity of four pass suture passage (one way analysis of variance p=0.61). In simple terms there is no demonstrable difference in the strength of construct whether the surgeon uses four simple, two mattress or one grasping suture. This study allows the surgeon to justify using the simplest configuration of suture passage that works in his hands in order to obtain a reliable and repeatable repair of the rotator cuff arthroscopically


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 294 - 294
1 Mar 2004
Feroussis J Zografidis A Konstantinou N Dallas P Barbitsioti A
Full Access

Aim: The common cause for recurrent instability in older patients, is the massive tear of the rotator cuff tendons. This paper presents the results of the operative treatment for the above-mentioned rare and complex lesion. Method: Seven (7) patients, three (3) male and four (4) female with a mean age of 71 years developed recurrent shoulder instability as a result of trauma or preceding infection, which destroyed the rotator cuff. All cases presented with instability, pain and weakness, and in 2 cases the subluxation was obvious in every attempt to raise the arm. All of the patients had tears in at least two tendons of the rotator cuff. The cases were treated operatively with a combination of the Boytchev anterior stabilization procedure with an attempt to close the rotator cuff tear. A complete closure was achieved in 3 cases, and a partial closure in 2. In the remaining 2 cases the closure of the tear was impossible. All of the patients postoperatively underwent an early mobilization regime. Results: The mean follow-up was 30 months. Stabilization of the shoulder was achieved in 6 cases. Constant score varied from 50 to 85. One patient had a recurrent of the subluxation. All of the patients presented marked improvement in pain and in muscle strength. Two (2) of them developed almost full range of motion and satisfactory muscle strength. Four (4) patients presented decreased range of motion and muscle strength 50% of the unaffected arm, while one patient developed inability to raise his arm above 70 degrees. Conclusions: The combination of recurrent anterior instability with massive rotator cuff tears presents great difþculty in treatment especially in the cases where an infection had preceded. A complete closure of the rotator cuff tear is usually very difþcult to achieve


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 31 - 31
1 Jan 2003
Cofield RH
Full Access

Surgical repair of rotator cuff tendon is one of the most common orthopaedic procedures performed in the United States. This prospective single-surgeon study reports the long-term results of chronic rotator cuff repair. Vigorous statistical analysis was carried out to detect any association of various outcome parameters with the exact surgical pathology. 105 consecutive shoulders (97 patients) undergoing open repair of chronic (> 3 months) rotator cuff tear between 1975 to 1983 by the senior author were recruited to the study. Pain unresponsive to nonoperative treatment was the indication for surgery. The details of patient’s medical records, radiographic data, and the operative findings were prospectively reviewed. There were 67 males and 30 females with a mean age of 58 years (range, 38 to 75). Follow-up averaged 11 years with no patients lost to follow-up. There were 16 small, 40 medium, 38 large and 11 massive tears. Surgical repair relieved pain in 92% of patients (p< 0.0001). There was also a significant improvement in range of motion (p< 0.0001) and strength of abduction and external rotation following surgery (p< 0.0001). Return of movement and strength decreased with increasing tear size. At the latest follow-up results were rated as excellent in 68 shoulders, satisfactory in 12, and unsatisfactory in 25. 8 out of the 11 massive tears had unsatisfactory outcome. There were eight reoperations for traumatic retears. Standard tendon repair techniques combined with adequate postoperative protection and monitored physical therapy produced consistently satisfactory results. Introduction of experimental repair methods should be confined to those patients with massive tendon tears and only then with the hope of increasing function, as pain relief is satisfactory with usual treatment methods