Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

SUTURE FIXATION OF PROXIMAL HUMERAL FRACTURES: AN EFFECTIVE ALTERNATIVE TO METALWORK INSERTION



Abstract

Proximal humeral fractures are common and often occur in osteoporotic bone. Suture fixation utilises the rotator cuff tendons as well as bone providing adequate stability and avoids complications associated with metalwork insertion.

Surgical exposure was via a delto-pectoral approach with minimal dissection of the fracture site. Initially a 2 suture technique was utilized with heavy ethibond sutures passed through drill holes either side of the bicipital groove; however, because of concerns about varus instability the technique now uses a third suture placed laterally acting as a tension band to prevent varus collapse. Patients with Neer 2 and 3 part fractures treated with suture fixation were assessed clinically (using the Constant score) and radiologically at a mean of 27 months post fracture.

To date 24 patients have been studied. The average age of the patients in our series was 70.2. All fractures progressed to union with no cases of radiological avascular necrosis. We had 2 cases of mal-union (-one varus and one valgus-), both with a 2-suture technique. One patient had early loss of fixation; re-exploration was performed with stability conferred by a third lateral suture. Active abduction > 120o was achieved in 9 patients with a mean Constant score of 72 compared to 89 on the un-injured contra-lateral side. We have demonstrated that suture fixation of displaced proximal humeral fractures is an effective alternative to fixation using metalwork. The advantages are that minimal soft tissue stripping of the fracture site is required and the potential problems associated with metalwork insertion into osteoporotic bone are avoided. Following one case of varus mal-union with a 2-suture technique we now routinely use a third suture to act as a lateral tension band.

The abstracts were prepared by Mr Tim Briggs. (Editoral Secretary 2003/4) Correspondence should be addressed to him at Lane Farm, Chapel Lane, Totternhoe, Dunstable, Bedfordshire LU6 2BZ, United Kingdom